BLD2021-1571_Other_11.17.2021_5.24.36_PM_2526160N v L0 A I B I C I D I E I F I G I H AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY f. ti DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, r 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY y -- - 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT - LABORATORY SHALL LIST ALL OF WORK. - EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. r% INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER -CONDITIONING AT THE UL-LISTED LOCATION PROVIDED INVERTER. 40 BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO SHALL BE BONDED WITH EQUIPMENT BE GROUNDED GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED ' = -A" ,.. - AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING 7. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED SPECIFICATIONS. 8. ALL WORK TO BE IN COMPLIANCE WITH RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. 690.47. (IBC) _ 9. ALL ELECTRICAL WORK TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE (NEC). SHEET INDEX }® doo PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM PV 2 SITE PLAN PV 6 PLACARD PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED PV 4 CHIKO MOUNTING - DRAWN BY: DRAWING SCALE: CONFIDENTIAL - THE INFORMATION CONTAINED PLG CUSTOM IN THIS PACKET AND SUBSEQUENT CUTSHEETS Roberto DESIGN DATE: 12/10/2021 SHALL NOT BE USED FOR THE BENEFIT OF S O L G N SOLGEN POWER uentes ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN pV 1 CONSENT FROM SOLGEN POWER. A B C D E F G H N INDEX: W E 4 MODULE TYPE: 2 S 5 3 COMP. SHINGLE N N M W p O WAC 51-54A-1204.2.1 I FC 2018 EXCEPTION 5 1 SOLAR OFFSETS ROOF AREA: 3817.18 Ft2 CIRCUIT 1 � PV AREA: 600.08 Ft2 CIRCUIT 2� ROOF %: 15.72% CIRCUIT 3 / DRAWN BY: DRAWING SCALE: CONFIDENTIAL - THE INFORMATION CONTAINEDPLG 7/64" - 1'-0" IN THIS PACKET AND SUBSEQUENT CUTSHEETS Roberto Fuentes DATE: DESIGN SO LG � N SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 12/10/2021 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE # CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 2 CONSENT FROM SOLGEN POWER. SYSTEM SIZE DC:12.24kW RAFTER SPACING:24" O.C. SYSTEM SIZE AC:10.20kW NUMBER OF MODULES:34 RAFTER SIZE:2" x 6" zNSHINE ZXM6-NH 120-360M INVERTER: Hoymiles Series MODULES 0 UTILITY METER O2 MAIN SERVICE COMBINER BOX O O AC DISCONNECTO A CIRCUIT # MODU CIRCUIT 1 11 CIRCUIT 2 11 CIRCUIT 3 12 NOTES: 1. 200A UTILITY METER GLOBE ONLY. (E} 2. 200A LOAD CENTER. (EXISTING) 3. 60A RATED FUSED LOCKABLE AC DISC 60A FUSES. (NEW) 4. 125A RATED COMBINER PANEL. (NEW) ALL CONDUIT SIZES ARE MINIMUM SIZES ALL WIRE SIZES ARE FOR COPPER WIRE V Y)I ti 1 U I TOTAL AMPS AVAILABLE kL MAIN BREAKER MAX BREAKER SIZE 200A = 40A COMBINER BOX PANEL SIZE CALCS MBER OF NOMINAL OUTPUT TOTAL 125% )INVERTERS CURRENT IN AMPS 11 x 1.25 = 13.75 x 1.25 11 x 1.25 = 13.75 x 1.25 U BREAKER SIZE 20A 20A L MAX AC OPERATING CURRENT CALCS # OF MICROINVERTERS 34 MAX OUTPUT CURRENT MAX AC OPERATING CURRENT = 42.50A x 1.25 FUSE SIZE CALCS MAX AC OPERATING CURRENT 125 % TOTAL FUSE SIZE 42.50A x 1.25 x 53.13A = 60A UTILITY METER (E) Y SERVICE PANEL (E) UPPLY-SIDE INTERCONNECTION 'ER NEC 705.11(B) 'ERIFY CONDUCTOR SIZE, 4/0 AL )R 2/0 CU IN I I-�' �M DRAWN BY: DRAWING SCALE: CONFIDENTIAL - THE INFORMATION CONTAINED PLG NOT TO SCALE IN THIS PACKET AND SUBSEQUENT CUTSHEETS Roberto Fuentes DATE: DESIGN SO LG E. N SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 12/10/2021 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 Arip P 0 W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE # CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV CONSENT FROM SOLGEN POWER. 3 A B C D E F G H 5'9" 13.8' 3'5'' 0.67" 6" SOLAR PANEL ROOFING L FEET o� LO N FLASHING 7# Rail N D co W 14.24' STRUCTURAL NOTES: Mount to Existing Rafters 1. TOTAL WEIGHT (MODULE &RAIL): 1774 LBS 4' 4' 4' 2. RAIL WEIGHT: 237 LBS 3. MODULE WEIGHT: 1537 LBS Mid Clamp End Clamp 4. DISTRIBUTED WEIGHT: 2.62 PSF ; i ` Grounding Lug77 I CONFIDENTIAL - THE INFORMATION CONTAINED DRAWN BY: PLG DESIGN IN THIS PACKET AND SUBSEQUENT CUTSHEETS Roberto Fuentes DATE: SOLGr.N SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SOLGEN POWER 5100 ELM RD, 12/10/2021 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 PAGE # P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 4 CONSENT FROM SOLGEN POWER. A 1 b 1 c; 1 u 1 t 1 r U PV MODULE - MOUNTING FEET CHIKO #7 RAIL 2 MOUNTING DIAGRAM SCALE: NOT TO SCALE STRUCTURAL NOTES: 1. 48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHT OVER SUPPORT OF TRUSSES 2. MOUNTING FEET ARE IN APPROXIMATE LOCATION. 3. MOUNTING FEET SHOULD BE STAGGERED AS SHOWN IN DIAGRAM 1 IMOUNTING DIAGRAM �M DRAWN BY: DRAWING SCALE: CONFIDENTIAL - THE INFORMATION CONTAINED PLG 15/128" = 1'-0" IN THIS PACKET AND SUBSEQUENT CUTSHEETS DESIGN SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER Roberto Fuentes DATE: SO L G C N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 12/10/2021 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN AGE # CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN 5 CONSENT FROM SOLGEN POWER. IPV rwEl a IN IN a A El a El I El on on 3. No CAUTION POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 18117 80th Ave West, Edmonds, WA 98026 MA S J V!_ I I \ I V! I\I\! I V V I 11 I MICROINVERTERS ROOF MOUNTED SOLGEN P O W E R 6 "x6" FA CAUTION 1 soLAR ELEGTFiIU Si YSTEIA CONNECTED J L6M 51.ES" :=3p ff TM E0_1I%FYTFFD UY UULTIPLE SJL*= TOLLL NAMING #ALL 04LIS LgVNMT DEMES. 0 CLUDMG YAW :AYfLY 0ABIK L#b%E MT DEAN MALL N07 EXCEED rnPAcrrrov DU'G&R 13U1 PCTVIIER SUPPLY SEg1 MS UTf.IT" GRO MO PY 10 AR FI FURIC $Y$TFN SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTLhfJ'VYftV MI.L„E TORN RERDS-11F IOWNWpRTO 7WO F' PWITICN TO W WON PV SY WANDI CI= sepalWARD EITWAN'thY Inside Panel CONFIDENTIAL - THE INFORMATION CONTAINE IN THIS PACKET AND SUBSEQUENT CUTSHEETS NOT BE USED FOR THE BENEFIT OF SOLGEN POWER SOL G��SHALL ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 P o W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. Enphaso Comb'InF ARNIN ELECTRIC SHOCK HAZARD TERMINALS ON THE LINEAND LOAD SIDES MAY BE ENERGIZE} _.IN IN THE OPEN POSITION Soladeck & Junction Boxes A CAUTION -,SOLAR CIRCUIT Conduit: Every 10' A CAUTION ,_SOLAR CIRCUIT _ PV SYSTEM kWh Meter DRAWN BY: Roberto Fuentes DATE: AC Disconnect � V[MWiA°a0NM1D1�TYlE .va 11111�K1•:. L-. Nllll SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN hMd! TUIN RAPID SARDOWN SNTCH To THE'CFF PMMON TO SHUT Dam I PYSYSTRANDREDUDE SHDCM RAZARDINTFE ARRAY IGN PLG 12/10/2021 PAGE # 18117 80th Ave West, Edmonds, WA 98026 PV 6 .1- EIRN ■ [+—V .V Elm