BLD2021-1571_Other_11.17.2021_5.24.36_PM_2526160N
v
L0
A I B I C I D I E I F I G I H
AERIAL VIEW
ELECTRICAL NOTES
GENERAL NOTES
1. WHERE ALL TERMINALS OF THE
1. PRIOR TO THE COMMENCEMENT OF ANY
f. ti
DISCONNECTING MEANS MAY BE
WORK, THE CONTRACTOR SHALL NOTIFY
ENERGIZED IN THE OPEN POSITION, A
THE DESIGNER OF ANY DISCREPANCIES
SIGN WILL BE PROVIDED WARNING OF
WITH THE DESIGN IN ANY CAPACITY.
THE HAZARDS. (PER ART. 690.17)
ESPECIALLY RECOMMENDATIONS, CODES,
r
2. EACH UNGROUNDED CONDUCTOR OF
OR REGULATIONS & RULES OF THE
THE MULTIWIRE BRANCH CIRCUIT WILL
AUTHORITY HAVING JURISDICTION, WHICH
BE IDENTIFIED BY PHASE AND SYSTEM.
SUPERSEDED THE NEC.
(PER ART. 210.5)
2. ALL DIMENSIONS TO BE VERIFIED BY
y -- -
3. A NATIONALLY RECOGNIZED TESTING
CONTRACTOR PRIOR TO COMMENCEMENT
-
LABORATORY SHALL LIST ALL
OF WORK.
-
EQUIPMENT IN COMPLIANCE WITH
3. CONTRACTOR IS RESPONSIBLE FOR ALL
ARTICLE 110.3.
SAFETY PRECAUTIONS, OSHA
4. ALL WIRES SHALL BE PROVIDED WITH
REQUIREMENTS ETC. FOR THE SITE,
STRAIN RELIEF AT ALL ENTRY POINTS
INCLUDING EXISTING SITE HAZARDS.
r%
INTO BOXES AS REQUIRED BY UL LISTING
4. SYSTEM IS GRID INTERACTIVE/INTERTIED
5. MODULE FRAMES SHALL BE GROUNDED
VIA A UL LISTED POWER -CONDITIONING
AT THE UL-LISTED LOCATION PROVIDED
INVERTER.
40
BY THE MANUFACTURER USING
5. SYSTEM HAS NO ENERGY STORAGE OF
UL-LISTED GROUNDING HARDWARE.
ANY KIND, OR UPS.
6. MODULE FRAMES, RAIL, AND POSTS
6. ALL SOLAR MOUNTING FRAMEWORK TO
SHALL BE BONDED WITH EQUIPMENT
BE GROUNDED
GROUND CONDUCTORS AND GROUNDED
7. FOLLOW MANUFACTURERS SUGGESTED
' = -A" ,.. -
AT THE MAIN ELECTRICAL PANEL.
INSTALLATION PRACTICES AND WIRING
7. THE DC GROUNDING ELECTRODE
CONDUCTOR SHALL BE SIZED
SPECIFICATIONS.
8. ALL WORK TO BE IN COMPLIANCE WITH
RESIDENCE PHOTO
ACCORDING TO ARTICLE 250.166B &
THE INTERNATIONAL BUILDING CODES.
690.47.
(IBC)
_
9. ALL ELECTRICAL WORK TO BE IN
COMPLIANCE WITH THE NATIONAL
ELECTRIC CODE (NEC).
SHEET INDEX
}®
doo
PV 1 COVER PAGE
PV 5 MOUNTING DIAGRAM
PV 2 SITE PLAN
PV 6 PLACARD
PV 3 ELECTRICAL DIAGRAM
CUT SHEETS ATTACHED
PV 4 CHIKO MOUNTING
-
DRAWN BY:
DRAWING SCALE:
CONFIDENTIAL - THE INFORMATION CONTAINED
PLG
CUSTOM
IN THIS PACKET AND SUBSEQUENT CUTSHEETS
Roberto
DESIGN
DATE:
12/10/2021
SHALL NOT BE USED FOR THE BENEFIT OF
S O L G N
SOLGEN POWER
uentes
ANYONE OUTSIDE SOLGEN POWER. NEITHER
5100 ELM RD,
SHALL IT BE DISCLOSED TO OTHERS OUTSIDE
PASCO, WA 99301
1
P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN
PAGE#
CONNECTION WITH THE SALE AND USE OF THE
P: 509-931-1663
18117 80th Ave West, Edmonds, WA 98026
RESPECTIVE EQUIPMENT, WITHOUT WRITTEN
pV 1
CONSENT FROM SOLGEN POWER.
A B C D E F G H
N
INDEX:
W E
4
MODULE TYPE:
2
S 5
3 COMP. SHINGLE
N N
M W
p O
WAC 51-54A-1204.2.1 I FC
2018
EXCEPTION 5 1
SOLAR OFFSETS
ROOF AREA: 3817.18 Ft2 CIRCUIT 1 �
PV AREA: 600.08 Ft2 CIRCUIT 2�
ROOF %: 15.72% CIRCUIT 3 /
DRAWN BY: DRAWING SCALE:
CONFIDENTIAL - THE INFORMATION CONTAINEDPLG 7/64" - 1'-0"
IN THIS PACKET AND SUBSEQUENT CUTSHEETS Roberto Fuentes DATE: DESIGN
SO LG
� N SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER
ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 12/10/2021
SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301
P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE #
CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026
RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 2
CONSENT FROM SOLGEN POWER.
SYSTEM SIZE DC:12.24kW RAFTER SPACING:24" O.C.
SYSTEM SIZE AC:10.20kW
NUMBER OF MODULES:34 RAFTER SIZE:2" x 6"
zNSHINE
ZXM6-NH 120-360M
INVERTER: Hoymiles Series
MODULES 0
UTILITY METER O2
MAIN SERVICE
COMBINER BOX
O
O
AC DISCONNECTO
A
CIRCUIT #
MODU
CIRCUIT 1
11
CIRCUIT 2
11
CIRCUIT 3
12
NOTES:
1. 200A UTILITY METER GLOBE ONLY.
(E}
2. 200A LOAD CENTER. (EXISTING)
3. 60A RATED FUSED LOCKABLE
AC DISC
60A FUSES. (NEW)
4. 125A RATED COMBINER PANEL.
(NEW)
ALL CONDUIT SIZES ARE MINIMUM
SIZES
ALL WIRE SIZES ARE FOR COPPER
WIRE
V
Y)I
ti 1 U I
TOTAL AMPS AVAILABLE
kL MAIN BREAKER MAX BREAKER SIZE
200A = 40A
COMBINER BOX PANEL SIZE CALCS
MBER OF NOMINAL OUTPUT TOTAL 125%
)INVERTERS CURRENT IN AMPS
11 x 1.25 = 13.75 x 1.25
11 x 1.25 = 13.75 x 1.25
U
BREAKER SIZE
20A
20A
L
MAX AC OPERATING CURRENT CALCS
# OF MICROINVERTERS
34
MAX OUTPUT CURRENT
MAX AC OPERATING CURRENT
= 42.50A
x
1.25
FUSE SIZE CALCS
MAX AC OPERATING CURRENT 125 % TOTAL FUSE SIZE
42.50A x 1.25 x 53.13A = 60A
UTILITY METER (E)
Y
SERVICE PANEL (E)
UPPLY-SIDE INTERCONNECTION
'ER NEC 705.11(B)
'ERIFY CONDUCTOR SIZE, 4/0 AL
)R 2/0 CU
IN
I
I-�'
�M
DRAWN BY: DRAWING SCALE:
CONFIDENTIAL - THE INFORMATION CONTAINED PLG NOT TO SCALE
IN THIS PACKET AND SUBSEQUENT CUTSHEETS Roberto Fuentes DATE: DESIGN
SO LG E. N SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER
ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 12/10/2021
SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301
Arip P 0 W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE #
CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026
RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV
CONSENT FROM SOLGEN POWER. 3
A B
C
D
E F
G H
5'9"
13.8'
3'5''
0.67"
6"
SOLAR PANEL
ROOFING
L FEET
o�
LO
N
FLASHING
7# Rail
N
D
co
W
14.24'
STRUCTURAL NOTES:
Mount to Existing Rafters
1. TOTAL WEIGHT (MODULE &RAIL): 1774 LBS
4'
4'
4'
2. RAIL WEIGHT: 237 LBS
3. MODULE WEIGHT: 1537 LBS
Mid Clamp
End Clamp
4. DISTRIBUTED WEIGHT: 2.62 PSF
;
i
`
Grounding Lug77
I
CONFIDENTIAL - THE INFORMATION CONTAINED
DRAWN BY:
PLG
DESIGN
IN THIS PACKET AND SUBSEQUENT CUTSHEETS
Roberto Fuentes
DATE:
SOLGr.N
SHALL NOT BE USED FOR THE BENEFIT OF
ANYONE OUTSIDE SOLGEN POWER. NEITHER
SOLGEN POWER
5100 ELM RD,
12/10/2021
SHALL IT BE DISCLOSED TO OTHERS OUTSIDE
PASCO, WA 99301
PAGE #
P O W E R
THE RECIPIENT'S ORGANIZATION, EXCEPT IN
CONNECTION WITH THE SALE AND USE OF THE
P: 509-931-1663
18117 80th Ave West,
Edmonds, WA 98026
RESPECTIVE EQUIPMENT, WITHOUT WRITTEN
PV 4
CONSENT FROM SOLGEN POWER.
A 1 b 1 c; 1 u 1 t 1 r
U
PV MODULE -
MOUNTING FEET
CHIKO #7 RAIL
2 MOUNTING DIAGRAM
SCALE: NOT TO SCALE
STRUCTURAL NOTES:
1. 48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHT
OVER SUPPORT OF TRUSSES
2. MOUNTING FEET ARE IN APPROXIMATE LOCATION.
3. MOUNTING FEET SHOULD BE STAGGERED AS
SHOWN IN DIAGRAM
1 IMOUNTING DIAGRAM
�M
DRAWN BY: DRAWING SCALE:
CONFIDENTIAL - THE INFORMATION CONTAINED PLG 15/128" = 1'-0"
IN THIS PACKET AND SUBSEQUENT CUTSHEETS DESIGN
SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER Roberto Fuentes DATE:
SO L G C N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 12/10/2021
SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301
P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN AGE #
CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 18117 80th Ave West, Edmonds, WA 98026
RESPECTIVE EQUIPMENT, WITHOUT WRITTEN 5
CONSENT FROM SOLGEN POWER. IPV
rwEl
a
IN
IN
a
A
El
a
El
I
El
on
on
3.
No
CAUTION
POWER TO THIS BUILDING IS SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
18117 80th Ave West, Edmonds, WA 98026
MA
S
J V!_ I I \ I V! I\I\! I V V I 11 I
MICROINVERTERS
ROOF MOUNTED
SOLGEN
P O W E R
6 "x6"
FA CAUTION 1
soLAR ELEGTFiIU Si YSTEIA CONNECTED J
L6M 51.ES" :=3p
ff
TM E0_1I%FYTFFD UY UULTIPLE
SJL*= TOLLL NAMING #ALL
04LIS LgVNMT DEMES. 0 CLUDMG
YAW :AYfLY 0ABIK L#b%E MT
DEAN MALL N07 EXCEED
rnPAcrrrov DU'G&R
13U1 PCTVIIER SUPPLY
SEg1 MS UTf.IT" GRO MO
PY 10 AR FI FURIC $Y$TFN
SOLAR PV SYSTEM
EQUIPPED WITH
RAPID SHUTLhfJ'VYftV
MI.L„E
TORN RERDS-11F IOWNWpRTO
7WO F' PWITICN TO W WON
PV SY WANDI CI=
sepalWARD EITWAN'thY
Inside Panel
CONFIDENTIAL - THE INFORMATION CONTAINE
IN THIS PACKET AND SUBSEQUENT CUTSHEETS
NOT BE USED FOR THE BENEFIT OF
SOLGEN POWER
SOL G��SHALL
ANYONE OUTSIDE SOLGEN POWER. NEITHER
5100 ELM RD,
SHALL IT BE DISCLOSED TO OTHERS OUTSIDE
PASCO, WA 99301
P o W E R
THE RECIPIENT'S ORGANIZATION, EXCEPT IN
CONNECTION WITH THE SALE AND USE OF THE
P: 509-931-1663
RESPECTIVE EQUIPMENT, WITHOUT WRITTEN
CONSENT FROM SOLGEN POWER.
Enphaso Comb'InF
ARNIN
ELECTRIC SHOCK HAZARD
TERMINALS ON THE LINEAND
LOAD SIDES MAY BE ENERGIZE}
_.IN IN THE OPEN POSITION
Soladeck & Junction Boxes
A CAUTION
-,SOLAR CIRCUIT
Conduit: Every 10'
A CAUTION
,_SOLAR CIRCUIT _
PV SYSTEM kWh Meter
DRAWN BY:
Roberto Fuentes DATE:
AC Disconnect
� V[MWiA°a0NM1D1�TYlE .va
11111�K1•:. L-.
Nllll
SOLAR PV SYSTEM
EQUIPPED WITH
RAPID SHUTDOWN
hMd!
TUIN RAPID SARDOWN SNTCH To
THE'CFF PMMON TO SHUT Dam
I PYSYSTRANDREDUDE
SHDCM RAZARDINTFE ARRAY
IGN
PLG
12/10/2021
PAGE #
18117 80th Ave West, Edmonds, WA 98026 PV 6
.1-
EIRN
■ [+—V
.V
Elm