Stormwater Infiltration Report - 806 Cary Rd - Edmonds - 1-23-20 - Krazan 09219016STORMWATER INFILTRATION STUDY
PROPOSED KENTNER SFR
806 CARY ROAD
EDMONDS, WASHINGTON 98020
Project No. 092-19016
JANUARY 23, 2020
Prepared for:
DANIEL AND TRESSA KENTNER
806 CARY ROAD
EDMONDS, WA 98020
Prepared by:
KRAZAN & ASSOCIATES, INC.
GEOTECHNICAL ENGINEERING DIVISION
4303 — 198t' St SW
Lynnwood, Washington 98036
(425) 485-5519
�Irazan & ASSOCIATES,INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
January 23, 2020
Daniel and Tressa Kentner
806 Cary Road
Edmonds, WA 98020
Reference: Stormwater Infiltration Study
Proposed Kentner SFR
806 Cary Road
Edmonds, WA 98020
Greetings,
Krazan File Number 092-19016
Email: daniel.kentner@yahoo.com
tressakentner@ymail.com
Phone: 626-388-6602
In accordance with your request, we have completed a Stormwater Infiltration Study for the referenced
site. The results of our investigation are presented in the attached report.
If you have any questions, or if we can be of further assistance, please do not hesitate to contact our
office.
Respectfully submitted,
KRAZAN & ASSOCIATES, INC.
Michael D. Rundquist, P.E.
Senior Project Manager
JGL/MDR
Offices Serving The Western United States
4303 — 1981 St SW • Lynnwood, Washington 98036 • (425) 485-5519 • Fax: (425) 485-6837
I'(raZ;an & ASSOCIATEs,INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
TABLE OF CONTENTS
INTRODUCTION.............................................................................................................................................1
PROJECTDESCRIPTION.............................................................................................................................. I
PURPOSE AND SCOPE..................................................................................................................................1
GEOLOGICSETTING.................................................................................................................................... 2
FIELD INVESTIGATION............................................................................................................................... 2
STORMWATER INFILTRATION RATE - "PIT" METHOD...................................................................3
CONCLUSIONS AND RECOMMENDATIONS.......................................................................................... 4
TESTINGAND INSPECTION........................................................................................................................ 5
LIMITATIONS................................................................................................................................................. 5
VICINITYMAP....................................................................................................................................Figure 1
SITEPLAN............................................................................................................................................Figure 2
FIELD INVESTIGATION AND LABORATORY TESTING .................................................. Appendix A
Offices Serving The Western United States
4303 —198"' St SW • Lynnwood, Washington 98036 • (425) 485-5519 • Fax: (425) 485-6837
�1ra7_ an & ASSOCIATES,INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
January 23, 2020
STORMWATER INFILTRATION STUDY
PROPOSED KENTNER SFR
806 CARY ROAD
EDMONDS, WASHINGTON 98020
INTRODUCTION
KA Project No. 092-19016
This report presents the results of our stormwater Pilot Infiltration Test (PIT) study for the residential
project located at 806 Cary Road in Edmonds, Washington, as shown on the Vicinity Map in Figure 1.
The scope of this stormwater infiltration study was outlined in our proposal (Krazan proposal number
G19979WAL), dated December 6, 2019.
We have been requested to conduct stormwater infiltration testing to aid in project design. The scope of
work for geotechnical engineering services includes the exploration and evaluation of subsurface soil
and groundwater conditions at the project site, with geotechnical conclusions and recommendations
regarding stormwater infiltration presented in a written report.
PROJECT DESCRIPTION
It is our understanding that the project will include the demolition of the existing house and the
construction of a new, multi -story single family residence (SFR). The project site is located in a
residential neighborhood, with a relatively level to gently sloping ground surface.
We have been provided with a survey drawing prepared by West Alliance Professional Land Surveyors
titled, "Final Short Plat for Mike & Sabina Norton," dated December 1, 2018. Project plans for the new
residence have not been provided at this time.
PURPOSE AND SCOPE
We have been requested to conduct a geotechnical investigation for stormwater infiltration testing to aid
in project design. It is our understanding that the City of Edmonds refers to the Washington State
Department of Ecology (DOE) "Stormwater Management Manual for Western Washington," (2012,
updated 2014) for stormwater management on development projects. The Washington DOE stormwater
manual indicates that a stormwater Pilot Infiltration Test (PIT) should be used to determine the
stormwater infiltration rate for a project site.
Offices Serving The Western United States
4303 - 1981 St SW • Lynnwood, Washington 98036 • (425) 485-5519 • Fax: (425) 485-6837
KRAZAN & ASSOCIATES, INC.
GEOLOGIC SETTING
KA No. 092-19016
Stormwater Infiltration Study
Proposed Kentner SFR
806 Cary Road
Edmonds, WA
January 23, 2020
Page No. 2
The "Geologic Map of the Edmonds East and Part of the Edmonds West Quadrangles, Washington,"
compiled by James P. Minard (USGS, 1983) indicates that the property is underlain by the Quaternary
Whidbey Formation (Qw). The Whidbey Formation includes sediment from an ancient interglacial
period of time. The map unit description indicates that the interglacial sediments generally consist of
compact, bedded sand. Layers of compact peat and organic -rich sand are also present within the
formation at some locations.
FIELD EXPLORATION
We visited the site on January 3, 2020 to explore the subsurface soil and groundwater conditions and
preform a small-scale pilot infiltration test (PIT) in the eastern portion of the site as shown on the Site
Plan in Figure 2.
The two soil excavations (INF-1 and TP-1) were both excavated to a depth of approximately 6.0 feet
below current grade. Geotechnical representatives from Krazan and Associates were present during the
stormwater testing, examined the subsurface soil conditions encountered, obtained samples of the
subsurface soils, and maintained logs of the explorations.
Subsurface Conditions: Two (2) soil excavations were conducted for the subsurface investigation.
The following paragraphs include soil descriptions for each pit location.
Infiltration Pit 1 (INF-1) was located in the eastern portion of the property. INF-1 encountered
approximately 0.5 foot of sod and topsoil. Underlying the sod and topsoil, INF-1 exposed brown silty
sand with gravel and organics to a depth of about 2.0 feet below the ground surface. We interpreted this
material to be undocumented fill. Underlying the fill material, INF-1 exposed medium dense, rusty
brown silty sand with gravel, trace cobbles and trace organics to a depth of approximately 5.0 feet
below grade. We interpreted the medium dense, rusty brown silty sand to be native weathered soil.
Below the weathered soil, INF-1 exposed dense to very dense, gray silty sand with gravel to the depth
explored of about 6.0 feet below grade. We interpreted the dense to very dense, silty sand with gravel
to be native glacial till.
Test Pit 1 (TP-1) was located in the southeast portion of the property. TP-1 encountered approximately
0.5 foot of sod and topsoil. Underlying the sod and topsoil, TP-1 exposed brown silty sand with gravel
and organics to a depth of about 2.0 feet below the ground surface. We interpreted this material to be
undocumented fill. Underlying the fill material, the test pit exposed medium dense, rusty brown to gray
silty sand with gravel, trace cobbles and trace organics to a depth of approximately 4.0 feet below grade.
We interpreted the medium dense, rusty brown to gray silty sand to be native weathered soil. Below the
Krazan & Associates, Inc.
Offices Serving The Western United States
KRAZAN & ASSOCIATES, INC.
KA No. 092-19016
Stormwater Infiltration Study
Proposed Kentner SFR
806 Cary Road
Edmonds, WA
January 23, 2020
Page No. 3
weathered soil, the test pit exposed dense to very dense, gray silty sand with gravel to the depth
explored of about 6.0 feet below the ground surface. We interpreted the dense to very dense soil to be
native glacial till.
Groundwater: The test pits were checked for the presence of groundwater. Soil conditions were moist
to wet, however we did not observe groundwater seepage in the explorations at the time of our site visit.
Perched groundwater can occur when surface water infiltrates through less dense, more permeable soils
and accumulates on top of a relatively low permeability soil layer. Perched water does not represent a
regional groundwater "table" within the upper soil horizons. Perched water tends to vary spatially and
is dependent upon the amount of rainfall. We would expect the amount of perched water to decrease
during drier times of the year and increase during wetter periods.
It should be recognized that groundwater elevations may fluctuate with time. The groundwater level
will be dependent upon seasonal precipitation, irrigation, as well as other factors. Therefore,
groundwater levels at the time of the field investigation may be different from those encountered during
the construction phase of the project. The evaluation of such factors is beyond the scope of this report.
STORMWATER INFILTRATION RATE — "PIT" METHOD
The "Addendum to Edmonds Community Development Code Chapter 18.30" (Edmonds Stormwater
Addendum) indicates that stormwater infiltration rates can be determined using methods described in
Appendix B — "Methods for Determining Design Infiltration Rates". Section B.1.1 "Methods" indicates
that the small-scale PIT is an acceptable method for determining infiltration rates. Appendix B refers to
the Washington State Department of Ecology (DOE) "Stormwater Management Manual for Western
Washington," (SWMMWW) (2012, updated 2014) for Small -Scale PIT procedures.
Infiltration testing for this project was based on procedures outlined in Volume III of the SWMMWW.
One small-scale stormwater Pilot Infiltration Test was performed in the eastern (backyard) portion of
the property to evaluate the design stormwater infiltration rate, if feasible.
The PIT method for evaluating the stormwater infiltration rate of the site soils generally includes a
small-scale excavation in the area of the proposed infiltration system. The stormwater PIT at the project
site was performed at a depth of approximately 4.0 feet below the current ground elevation. The bottom
of the excavation for the small-scale PIT had a surface area of approximately 12 square feet.
The soils encountered at a depth of approximately 5.0 feet in INF-1 and at about 4.0 feet in TP-1
generally consisted of dense to very dense, gray silty sand with gravel to the depth explored. We
Krazan & Associates, Inc.
Offices Serving The Western United States
KRAZAN & ASSOCIATES, INC.
KA No. 092-19016
Stormwater Infiltration Study
Proposed Kentner SFR
806 Cary Road
Edmonds, WA
January 23, 2020
Page No. 4
interpreted the soils to be native glacial till. During the excavation, some of the soil was removed from
the test pits in concrete -like "chunks" due to the density of the material.
Water was added to the bottom of INF-1 for an initial soaking period. After the soaking period, the
water source was turned off and we initiated timed measurements of the water drawdown, also known
as the falling head infiltration test. Water in the stormwater PIT did not significantly change in
elevation during the approximately one hour long test, indicating very slow to almost insignificant
water infiltration into the soils.
CONCLUSIONS AND RECOMMENDATIONS
In our opinion, stormwater infiltration is not feasible at this property due to the very low
permeability of the underlying concrete -like, glacial till soils.
We recommend that other possibilities for stormwater runoff management be considered for this
residential project.
• On -Site Stormwater Dispersion: Edmonds City code indicates that stormwater dispersion
might be utilized where infiltration is not feasible. A dispersion system typically consists of
a perforated pipe at the bottom of a rock -filled trench with a level spreader. The level
spreader is typically made of wood or concrete and is intended to disperse water evenly
when the rock trench overflows. The rock would be exposed at the surface to allow water
to filter out of the trench and over the vegetated landscape nearby, such as a grass lawn.
Downspout splash blocks are another method for stormwater dispersion. However,
downspout splash blocks might not be allowed for this project, because 50 feet of vegetated
ground surface is required for the water flow path within the property. However, it may be
prudent to consult with the City to determine if an exemption might be allowed for this
prof ect.
• Off -Site Stormwater Outfall: It might be prudent to consider stormwater outfall in the
vicinity of Shell Creek or the creek buffer located beyond the east side of the property via
an easement. A drainage easement through the neighbor's property, with the owner's
approval as well as approval from the City, would be required. The outfall might include a
dispersion trench or similar feature to spread out the stormwater runoff to minimize the
impact to wetland or creek areas.
Krazan & Associates, Inc.
Offices Serving The Western United States
KRAZAN & ASSOCIATES, INC.
KA No. 092-19016
Stormwater Infiltration Study
Proposed Kentner SFR
806 Cary Road
Edmonds, WA
January 23, 2020
Page No. 5
• Connect to the City Storm System in Caspers Street: According to City Geographic
Information System (GIS) maps, the closest existing storm system catch basins are located
in Caspers Street near the intersection with Hanna Park Road. Additional catch basins are
located near the intersection of Caspers Street and 3' Avenue N.
This approach might be a feasible, although costly, option for stormwater management. It
may be worthwhile to consult with the City of Edmonds to discuss this approach.
Furthermore, it may be worthwhile to consult with neighboring property owners in regards
to the installation of a new stormwater line in Cary Road. This may spread out the cost of
the project.
The City of Edmonds, project architect and a civil engineer should be consulted to aid in
determining the most cost-effective approach regarding stormwater management for this project.
TESTING AND INSPECTION
We recommend that Krazan be retained to evaluate the soil conditions during construction of the
stormwater management system to confirm that the soil conditions are consistent with those
encountered in our explorations. This activity is an integral part of our services as acceptance of
earthwork construction is dependent upon observation of the consistency of the soil and groundwater
conditions, and making appropriate adjustments could be warranted if conditions vary from those
indicated by our explorations.
LIMITATIONS
Geotechnical engineering is one of the newest divisions of Civil Engineering. This branch of Civil
Engineering is constantly improving as new technologies and understanding of earth sciences improves.
Although your site was analyzed using the most appropriate current techniques and methods,
undoubtedly there will be substantial future improvements in this branch of engineering.
In addition to improvements in the field of geotechnical engineering, physical changes in the site either
due to excavation or fill placement, new agency regulations or possible changes in the proposed project
after the time of completion of the geotechnical report may require the geotechnical report to be
professionally reviewed. In light of this, the Owner should be aware that there is a practical limit to the
usefulness of this report without critical review. Although the time limit for this review is strictly
arbitrary, it is suggested that two years be considered a reasonable time for the usefulness of this report.
The recommendations made in this report are based on the assumption that soil and groundwater
conditions do not vary significantly from those disclosed during our field investigation. If any
Krazan & Associates, Inc.
Offices Serving The Western United States
KRAZAN & ASSOCIATES, INC.
KA No. 092-19016
Stormwater Infiltration Study
Proposed Kentner SFR
806 Cary Road
Edmonds, WA
January 23, 2020
Page No. 6
variations or undesirable conditions are encountered during construction, the geotechnical engineer
should be notified so that supplemental recommendations can be made.
The conclusions of this report are based on the information provided regarding any proposed
construction. If construction is relocated or redesigned, the conclusions in this report may not be valid.
The geotechnical engineer should be notified of any changes so that the recommendations can be
reviewed and re-evaluated.
The scope of our services did not include any environmental site assessment for the presence or absence
of hazardous and/or toxic materials in the soil, groundwater or atmosphere, or the presence of wetlands.
Any statements, or absence of statements, in this report or on any exploration log, regarding odors,
unusual or suspicious items, or conditions observed are strictly for descriptive purposes and are not
intended to convey engineering judgment regarding potential hazardous and/or toxic assessments.
The information presented herein is based upon professional interpretation utilizing standard
engineering practices and a degree of conservatism deemed proper for this project. It is not warranted
that such information and interpretation cannot be superseded by future developments. We emphasize
that this report is valid for this project as outlined above, and should not be used for any other site.
Krazan & Associates, Inc.
Offices Serving The Western United States
KRAZAN & ASSOCIATES, INC.
CLOSURE
KA No. 092-19016
Stormwater Infiltration Study
Proposed Kentner SFR
806 Cary Road
Edmonds, WA
January 23, 2020
Page No. 7
If you have any questions, or if we may be of further assistance, please do not hesitate to contact our
office at (425) 485-5519.
Respectfully submitted,
KRAZAN & ASSOCIATES, INC.
01/23/20
Michael D. Rundquist, P.E.
Senior Project Manager
JGL/MDR
wasIli
�� fo
2862 $�
used Geota
Jaffrey G. League
Jeffrey G. League, L.G.
Project Geologist
Krazan & Associates, Inc.
Offices Serving The Western United States
Vicinity Map N
(Not to Scale)
Approximate
v
Site Area
OIND ST SW 7921Y0 PL Sx,
EDMQ
;
DS
193RO STsw
jDIIG 24 I' A ST SW
L.
z
MA
W.
x
�—
�
k zn2N
W—
r
�� � DALEY ST
r
a i
aEL C S F
MAW!, ST
Heights
nAYroN sr
MAPLE 5T
�p - Marx sr sw 3
ALDER Sr
wCFMRST
21215T SW x
_
�
BpIN r X
SIN
�
h"AY S'v1 r•'
z
;
^
P� PWNE 5T
Pd
2 2 W6TH Sr $w
m�
r-
w EIR ST
27arf1 Sr sw
� I
�s
_
t�
210T1157 S W
—Ch Se—JL < 3
Lake m a
J
tz4 rN Sr SW
Wood ay
; ;
4' n 4
a I26TH ST 5w
; sperance 226TN PL SW
3
229TN sr IN < ; 229TN'ST•SW
v
& U
230TH ST SW
iO4 a
806 Cary Rd, Edmonds, WA
Reference: The Vicinity Map is based on a USGS topographic map titled,
"Edmond East Quadrangle - Washington", dated 2017.
=� K �ZZ & ASSOCIATES,INC.
Kentner SFR - Infiltration - Edmonds, WA
Date: January 2020 Project Number: 092-19016
Drawn By: NG Figure 1 Not to scale
Site Plan N
(Not to Scale)
Approximate Site Boundary
— — — — — — — — — — —
Driveway
INF-1
806 Cary Rd
Residence TP-1
----------------
LEGENDReference: The site plan is based on the PDS Map Portal
Snohomish County Planning and Development Services.
INF4 Number and Approximate
Location of Pilot
Infiltration TestZ & A S S O C I A T E S, I N C.
—Kraz;at
Tf Number and Approximate Kentner SFR - Infiltration - Edmonds, WA
Location of Test Pit Exploration ll
Note: Site plan features are approximate.
APPENDIX A
FIELD INVESTIGATION AND LABORATORY TESTING
Field Investigation
The field investigation consisted of a surface reconnaissance and a subsurface exploration program.
Two (2) pit explorations were excavated by a Krazan subcontractor, and the soils were sampled for the
subsurface exploration at this site. The soil explorations were conducted on January 3, 2020, and both
excavations were advanced to a depth of about 6.0 feet below the existing ground surface. Approximate
exploration locations are shown on the Site Plan (Figure 2). The depths shown on the attached soil logs
are from the existing ground surface at the time of our exploration.
The soils encountered were logged in the field during the subsurface exploration and, with
supplementary laboratory test data, are described in accordance with the Unified Soil Classification
System (USCS).
All samples from the explorations were returned to our laboratory for evaluation. The logs of the soil
explorations along with the laboratory test results are presented in this appendix.
Laboratory Testing
The laboratory testing program was developed primarily to determine the index properties of the soils.
Test results were used for soil classification and as criteria for determining the engineering
characteristics of the subsurface materials encountered.
Soil Classification
USCS Soil Classification
Major Division
Group Description
Coarse-
Grained
Soils
Gravel and
Gravelly Soils
< 50% coarse
fraction passes
#4 sieve
Gravel
(with little or no fines)
GW
Well -Graded Gravel
GP
Poorly Graded Gravel
Gravel
(with > 12% fines)
GM
Silty Gravel
GC
Clayey Gravel
< 50%
passes
#200
sieve
Sand and
Sandy Soils
> 50% coarse
fraction passes
#4 sieve
Sand
(with little or no fines)
SW
Well -Graded Sand
PoorlyGraded Sand
Silty Sand
SP
Sand
(with > 12% fines)
SM
SC
Clayey Sand
Fine-
Grained
Soils
Silt and Clay
Liquid Limit < 50
ML
Silt
CL
Lean Clay
OL
Organic Silt and Clay (Low Plasticity)
> 50%
passes
#200
sieve
Silt and Clay
Liquid Limit > 50
MH
Inorganic Silt
CH
Inorganic Clay
OH
Organic Clay and Silt (Med. to High Plasticity)
Highly Organic Soils
PT
Peat
Relative Density with Respect to SPT N-Value
Coarse -Grained Soils
Fine -Grained Soils
Density
N-Value (Blows/Ft)
Density
N-Value (Blows/Ft)
Very Loose
0-4
Very Soft
0-1
Loose
Medium Dense
5 -10
Soft
Medium Stiff
2-4
11 - 30
5-8
Dense
31 -50
Stiff
9 - 15
Very Dense
> 50
Very Stiff
16 - 30
Hard
> 30
LOG OF EXPLORATORY TEST PIT INF-1
KRAZAN AND ASSOCIATES, INC.
PROJECT: Kentner SFR - Infiltration DATE: 1/3/20
PROJECT NO.: 096-19016 PAGE: 1 of 1
CONTRACTOR: NW Exc. and Trucking SURFACE ELEV.: Approx. 42'
SAMPLE METHOD: Grab LOCATION: Edmonds, WA
Natural Moisture Content
and
Atterberg Limits
J
ca
J
W
J
MATERIAL DESCRIPTION
z°
W
a.
Plastic Moisture Liquid
=
y
w
W
a
W
Limit Content Limit
a.
o
?
�
Cl)
y
10 30 50 70
Sod and Topsoil
- - - ------------------------------------------------------------------------------------------------
Brown Silty Sand with Gravel and Organics
(Loose, Moist) (Fill)
1
2
---------------------------------------------------------------------------------------------------------------
Rusty Brown, Silty Sand with Gravel, Trace Cobbles
and Trace Organics
(SM)(Loose to Medium Dense, Moist)(Weathered Soils)
1
3
4
2
G
5
''
--------------------------------------------------------------
Gray Silty Sand with Gravel
(SM)(Dense to Very Dense, Moist)(Glacial Till)
3
6
End of Exploratory Test Pit
7
8
9
10
Water Level Initial: 0 Final: T
Water Observations: Groundwater seepage was not observed at the time of the soil exploration.
Notes: --
LOG OF EXPLORATORY TEST PIT TP-1
KRAZAN AND ASSOCIATES, INC.
PROJECT: Kentner SFR - Infiltration DATE: 1/3/20
PROJECT NO.: 096-19016 PAGE: 1 of 1
CONTRACTOR: NW Exc. and Trucking SURFACE ELEV.: Approx. 42'
SAMPLE METHOD: Grab LOCATION: Edmonds, WA
Natural Moisture Content
and
Atterberg Limits
J
ca
J
W
J
MATERIAL DESCRIPTION
z°
W
a.
Plastic Moisture Liquid
=
y
w
W
a
W
Limit Content Limit
a.
o
?
�
Cl)
y
10 30 50 70
Sod and Topsoil
- - - ------------------------------------------------------------------------------------------------
Brown Silty Sand with Gravel and Organics
(Loose, Moist) (Fill)
1
2
Rusty Brown to Gray, Silty Sand with Gravel, Trace Cobbles
1
G
and Trace Organics
(SM)(Loose to Medium Dense, Moist)(Weathered Soils)
3
2
G
4
------ -------- ------- -------- -------- --------
Gray, Silty Sand with Gravel
(SM)(Dense to Very Dense, Moist)(Glacial Till)
5
3
End of Exploratory Test Pit
7
8
9
10
Water Level Initial: 0 Final: T
Water Observations: Groundwater seepage was not observed at the time of the soil exploration.
Notes: --
0-1
W
Z
V_
Z
W
U
0_
W
0-
100
90
80
70
60
50
40
30
20
10
Krazan & Associates Sieve Analysis
000
N I I i
100 10 1 0.1 0.01 0.001
GRAIN SIZE - mm.
%+3„ % Gravel % Sand % Fines
Coarse I Fine Coarse I Medium Fine Silt Clay
0.0 3.2 13.4 7.7 16.0 34.9 24.8
Test Results (ASTM C-136 & ASTM C-117)
Opening
Percent
Spec."
Pass?
Size
Finer
(Percent)
(X=Fail)
1.25
100.0
1
96.8
.75
96.8
.5
93.8
.375
91.2
.25
86.7
#4
83.4
#10
75.7
#20
68.6
#40
59.7
#60
49.1
#100
39.9
#200
24.8
Material Description
Brown silty sand with gravel.
Atterberg Limits (ASTM D 4318)
PL= NP LL= NV PI= NP
Classification
USCS (D 2487)= SM AASHTO (M 145)= A-2-4(0)
Coefficients
D90= 8.4815 D85= 5.4978 D60= 0.4327
D50= 0.2617 D30= 0.0941 D15=
D10= Cu= Cc=
Remarks
Natural Moisture Content (ASTM D-2216): 12.4%
Date Received: 1/6/2020 Date Tested: 1/8/2020
Tested By: Cole Demas
Checked By: Corbett Mercer
Title: Lab Manager
(no specification provided)
Location: Test Pit 1 @ 5.5'
Sample Number: 69245 Depth: 5.5'
Client: Dan & Tressa Kentner
Project: Kentner SFR
Date Sampled: 1/6/2020