APPROVED BLD -BLD2020-0680_PLAN_SET_12-01-2020_15_37_48_Plan_SetLEGEND 0 cq +I w z_ J H w a SITE PLAN SCALE 22X34 1" = 10'-0" SCALE 11X17 1" = 20'-0" ADJACENT RESIDENCE I I I I — S.Y.S.B.5'— IT I I I I \ \ I � I I Z WALKWAY I I I I 1 co - -- 1 � I �, I • EXISTING RESIDENCE I \ I 845 DAYTON ST. EDMONDS WA S.Y.S.B. 5 � PROPERTY LINE ± 110' \�0 ° � VICINITY MAP FROM GOOGLE MAPS a ! i ca P=Peren � .9 tQemR.k �f .� T n r ;— ]jy O F E D M V '�swae i % ; E ,....., g a • Y 9 raappl!wiw�.o�A Nuddpellid tl<tu '� 1 r @imkmrrYw Ld',a'd[Cminp �\ Far1h \ •• a••'ux PM Wr nri. nl w sonsM � ;ilG■ � �y�pIC9 n Pnk Pg.NeM w— YNe WkeaYv i —w..e � oMdh �I��Pb�QQ � lrtdtlle SchadT ndWeB M � L _dnu�.ds &IS aeYlen�M e e3yn _ _ T ��^'t Munasx=EemonYarieedwer� 1!� �I mettle for __ wx 3 gem oah� � H�.p:hool � r�rorea%II� i lam --erg: #PwiRr Nan>,wed� 1 ,.� �ImdnQ'»• s..rn nv n»aw f -� i P, -,,, g PINE -.PARK r �' � NEIGHab�HO as i 9 n»„�+• � m xomka oroxan� / 9luekedl —. \Ca ••,�� we.kpe.p mexsw >mksa mveN� izlwatkw D°`a7i a�rhzme PROJECT INFORMATION OWNER WONG CHEE & SHERLYN Y JURISDICTION EDMONDS PARCEL NUMBER 00434207702500 ZONING RS6 YEAR BUILT 1976 LOT AREA 6600 SQ-FT PROJECT DESCRIPTION INTERIOR REMODEL TO EXISTING SFR. RENOVATING UPPER LEVEL KITCHEN AND REPLACE (E) SUNROOM TO DINING ROOM, PER PLAN LEGAL DESCRIPTION CITY OF EDMONDS BLK 077 D-00 LOTS 25-26 YARD CALCULATIONS 16.20.030.TABLE. REAR YARD =15 FEET REQUIRED REAR YARD = 15' FRONT YARD = 20 FEET REQUIRED FRONT YARD = 20' SIDE YARD = 5 FEET REQUIRED SIDE YARD = 5' CENTER OF STREET �I z �216,0� O Q 0 AREA TABULATIONS CONDITIONED SPACE BASEMENT LEVEL 1460 SQ-FT MAIN FLOOR LEVEL 1661 SQ-FT TOTAL 3121 SQ-FT EDGE OF CURB —214, 01 —I� APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 01 2211 51 10, 2 0' LOT COVERAGE 16.20.030.TABLE. TOTAL LOT AREA 6600 SQ-FT MAIN DWELLING 1850 SQ-FT PROPERTY LINE OF PROPOSED PROJECT PROPERTY LINE OF ADJACENT PROPERTIES CONTOUR LINE - 2' ELEVATION CHANGE x PROPOSED FENCE x EXISTING FENCE TO BE REMOVED x EXISTING FENCE EXISTING STRUCTURE W/ INTERIOR RENOVATION EXISTING STRUCTURE CENTER LINE OF STREET EDGE OF CONCRETE --- ROOF OUTLINE PROPERTY SETBACK - — — EDGE OF GRAVEL EASEMENT SHEET INDEX C1.1 SITE PLAN & PROJECT INFO A1.1 GENERAL NOTES & WINDOW & DOOR SCHEDULE TOTAL 1850 SQ-FT UNCONDITIONED SPACE A2.1 MAIN FLOOR DECK 276 SQ-FT A2.2 EXISTING BASEMENT PLANS GARAGE 443 SQ-FT ALLOWABLE LOT COVERAGE = 6600 * 35% = 2310 SQ-FT TOTAL 719 SQ-FT PROPOSED LOT COVERAGE = 1850 SQ-FT < 2310 SQ-FT (OK) A4.1 BUILDING SECTIONS TOTAL AREA 3840 SQ-FT A5.1 ARCHITECTURAL DETAILS City Of Edmonds Ruilrlinn nP-nartmPnt Work REMODEL -------------------- ------------------------------------------ Address 845 DAYTON ST Owner WONG Approved Date RI dirlinn nffirinl 12/14/2020 �J ---------------/- Permit Number BLD2020-0680 RESUB Dec 01 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z 0 LLI U Z U) Q LU J 0 � 0 LLI N Q N o wo Of i 1p 40 YEN DESIGN INC. 206.432.1111 WWW.YENDES.COM APPROVAL STAMP ENGINEER STAMP U) J w 0 oz 2p w o Q z U) rn Q o 3: w W zFoo o U) L4 } } op z �wLn0 Q00ul): -0'toLu z p LL 0- LLJ U LLI U) O 06 JOB NO. 20-242 HALF SCALE 11x17 FULL SCALE 22x34 SHEET C 1 . 1 GENERAL NOTES CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING THE WORK, WORK SHALL COMPLY WITH THE FOLLOWING CODES: 2015 INTERNATIONAL RESIDENTIAL CODE 2015 WASHINGTON ENERGY CODE OTHER CODES APPLICABLE BY JURISDICTION, AIR SEALING: 1, ALL PLUMBING, ELECTRICAL, AND HVAC PENETRATIONS IN FLOOR, WALLS, AND CEILINGS ARE CAULKED AND SEALED, 2, WHERE PENETRATIONS NEED A FIRESTOP, DISCUSS WITH BUILDING OFFICIAL, 3, ELECTRICAL OUTLET AND LIGHT SWITCH BOXES ON EXTERIOR WALLS MUST BE SEALED AT THE BACK OF THE RECEPTACLE OR SEALED WITH FACEPLATE GASKETS. 4, SEAL RIM JOIST BETWEEN HEATED FLOORS OR USE PRODUCT LIKE "TYVEK" ON EXTERIOR, 5, VAPOR BARRIER SHALL BE EITHER FACE STAPLED BATTS, 4 MIL, VISQUEEN OR AN APPROVED VAPOR BARRIER PAINT. SEPARATION BETWEEN DWELLING AND GARAGE/CARPORT; a, NO SEPARATION REQUIRED IF ENTIRELY OPEN ON 2 OR MORE SIDES AND NO ENCLOSED USES, (OPEN DECKS ABOVE ARE OKAY, NON -RATED WALLS AND OPERABLE WINDOWS BETWEEN THE DWELLING AND CARPORT ARE OKAY, b, MINIMUM 1/2" GWB ON GARAGE/CARPORT SIDE OF WALLS REQUIRED FOR ALL GARAGES/CARPORTS NOT COVERED BY 1A ABOVE, C. 1-HOUR FIRE RATED WALL REQUIRED IF LESS THAN 5 FEET FROM PROPERTY LINE (NO OPENINGS ALLOWED LESS THAN 3' FROM PROPERTY LINE, 25% MAXIMUM OPENINGS BETWEEN 3' AND 5' TO PROPERTY LINE, OVERHANGS MUST BE A MINIMUM 2' FROM PROPERTY LINE, EXCEPT STEEL GUTTER ALLOWED CLOSER AND 5/8" GWB SHEATHING REQUIRED ON UNDERSIDE WHEN 5' OR LESS FROM PROPERTY LINE, EGRESS WINDOWS: REQUIRED FOR 1 WINDOW/BEDROOM OR SLEEPING AREA (BELOW 4TH FLOOR) AND 1 WINDOW/BASEMENT, a, MIN, NET CLEAR AREA = 5,7 SQ. FT., MIN, 310" x 416" IF DOUBLE HUNG OR 410" x 316" WINDOW IF SLIDER, 5,0 SQ, FT, IF SILL HEIGHT IS WITHIN 44" OF GRADE (ABOVE OR BELOW, b, MIN, NET CLEAR OPENING WIDTH = 20"; MIN, NET CLEAR OPENING HEIGHT = 24" c, MAX. SILL HEIGHT = 44" BONE PERMANENTLY INSTALLED STEP WITH MAX, 8" RISE AND MIN, 9" RUN OKAY FOR EXISTING BEDROOMS), REQUIRED GLAZING FOR HABITABLE ROOMS: a. MIN. GLAZED EXTERIOR OPENING AREA = 8% OF FLOOR AREA, b, GLAZED OPENINGS NOT REQUIRED WHERE PERMANENTLY INSTALLED ARTIFICIAL LIGHT IS PROVIDED, C. OK IF OPENINGS ARE BELOW DECK & ROOFED PORCHES w/MIN, CEILING HEIGHT OF 7 FT, ALONG SIDE 65% OPENS, MECHANICAL/VENTILATION; REQUIRED FOR HABITABLE ROOMS OF ADDITIONS AND ALTERATIONS MORE THAN 500 SQ, FT, OR THAT INCLUDE A KITCHEN, BATHROOM AND OTHER AREAS WHERE COOKING ODOR OR EXCESS WATER VAPOR WILL BE PRODUCED, a, MIN. 50 CFM FOR BATHROOM AND LAUNDRY; MIN. 100 CFM FOR KITCHEN, b, MIN, AIR INTAKE OPENINGS = 4 SQ, IN, PER ROOM, c, WHOLE HOUSE FAN MUST OPERATE AS SPECIFIED IN IRC M1507,3 SMOKE ALARMS: REQUIRED INSIDE AND OUTSIDE OF SLEEPING AREAS AND ON ALL FLOORS, DIRECT WIRING IS REQUIRED FOR SMOKE DETECTORS, UNLESS REMOVAL OF INTERIOR WALL OR CEILING FINISHES IS NECESSARY TO INSTALL THE WIRING, CARBON MONOXIDE ALARMS: REQUIRED OUTSIDE SLEEPING AREAS AND ON ALL FLOORS, UNLESS WORK ONLY INVOLVES EXTERIOR SURFACES OF THE BUILDING, STAIR REQUIREMENTS: APPLIES TO ALL R-3 STAIRS AND R-2 PRIVATE STAIRWAYS: a. MIN, WIDTH = 36" b, MAX. HEIGHT/RISE = 7-3/4"; MIN. TREAD RUN = 10" C. MIN, HEADROOM = 6'8" d, HANDRAIL 34"-38" ABOVE TREAD NOSING (RETURN ENDS e, HANDRAIL GRASP DIMENSION; MIN. 1-1/411, MAX. 2" f, WINDING STAIRS: 1. MIN, TREAD RUN AT NARROWEST POINT = 6" 2, MIN, TREAD RUN 12" FROM NAORROWEST POINT = 10" g, SPIRAL STAIRS: 1, MIN, CLEAR WALKING AREA WIDTH = 26" 2, MIN. TREAD RUN 12" FROM NARROWEST POINT = 7-1/2" / MAX, RISER HEIGHT = 9-1/2" 3, MIN, HEADROOM = 616" CEILING HEIGHT IN ADDITIONS AND ALTERATIONS: a. MIN, 70", FOR NEW CONSTRUCTION OR ADDITIONS b, MIN, 64": IF BUILDING WAS IN EXISTENCE PRIOR TO 10/17/79 SEE DR 23-2008 FOR SPECIFICS, C. ROOMS WITH SLOPED CEILINGS REQUIRE MINIMUM CEILING HEIGHT IN 1/2 OF THE AREA. PORTIONS OF THE ROOM WITH CEILING HEIGHT LESS THAN 5 FT. DO NOT COUNT IN TOTAL AREA, INSULATION: 1L FACED BATTS ARE LAPPED AND FACE STAPLED AT FRAMING MEMBERS. 2, ALL EXTERIOR WALL CAVITIES ARE FILLED WITH UNCOMPRESSED INSULATION, INCLUDING ALL CAVITIES ISOLATED DURING FRAMING, WIRING, AND PLUMBING, 3, ALL RECESSED FIXTURES IN EXTERIOR WALLS HAVE RIGID BOARD INSULATION BEHIND THEM, 4, UNDERFLOOR INSULATION IS SUPPORTED BY LATH, TWINE, OR OTHER NON -COMPRESSING MEANS, 5, ATTIC ACCESS IS BAFFLED, WEATHER-STRIPPED AND INSULATED. FOUNDATION LOCATION: PROPERTY CORNERS MUST BE ACCURATELY DETERMINED AND INDICATED ON SITE FOR FOUNDATION INSPECTION, A SURVEY MAY BE REQUIRED. FENCE LOCATIONS WILL NOT BE ACCEPTED AS ESTABLISHING PROPERTY CORNERS, OTHER REQUIREMENTS; a, GUARDRAILS: MIN, 36" HT. MAX. 4" SPACING BETWEEN INTERMEDIATE MEMBERS �42" MIN. HT. FOR R-2 EXTERIOR), b, FOORINGS: BOTTOM MIN, 12" BELOW GRADE, TOP OF FOUNDATION WALL MIN, 6" ABOVE GRADE. c, CONRETE SLABS ON GRADE: 3-1/2" MIN. THICKNESSES, d, PIER BLOCKS: MIN, 12" X 12" SIZE; RESTING ON CONCRETE PAD MIN, 12" BELOW GRADE, e, FOUNDATION WALLS; PROVIDE ONE j1l #4 REBAR TOP AND BOTTOM AND AT ALL WINDOWS/DOOR OPENINGS, LIMIT 4' MAX. BACKFILL, f, FOUNDATION ANCHOR BOLTS: MIN, 1/2" x 10"1 6 FT, ON CENTER MAX. WITH TWO (21 BOLTS PER PIECE OF PLATE AND AT LEAST ONE j1� BOLT WITH 12" AT END OF EACH PIECE REQUIRED FOR NEW CONSTRUCTION), 9 ALL STRUCTURAL SOFTWOOD PLYWOOD, PARTICLE BOARD, WAFER BOARD, AND OSB BOARD ARE STAMPLED WITH EXPOSURE T OR 'EXTERIOR', h, WATER HEATER STORAGE TANK LABELED AS MEETING 1987 NAT'L APPLIANCE ENERGY CONSERVATION ACT. ASHRAE STANDARD 90A-1980 INSULATION TO R-16 OR R-10 PAD IF LOCATED OVER UNINSULATED SLAB, i, INSULATE HOT AND COLD WATER PIPES TO R-3 IN UNHEATED AREAS. j, SHOWER REGULATOR TO LIMIT HOT WATER DISCHARGE TO 2.5 GPM k, WOODSTOVES AND FIREPLACES HAVE TIGHT FITING DOORS, OUTSIDE COMBUSTION AIR DUCTED TO FIREBOX WITH ACCESSIBLE DAMPER, MIN 6 SQ IN FREE VENT AREA. TIGHT FITTING FLUE DAMPERS REQ'D, I. ALL GAS AND OIL COMBUSTION APPLIANCES HAVE A DIRECT VENT OR FORCED DRAFT VENTING. m, RECESSED LIGHTS ARE I,C, RATED, DOUBLE WALL CAN LIGHTS OR WITHIN SEALED WPGWB BOX -IN, n, CONTRACTOR TO PROVIDE �11 1611x24" MINIMUM CRAWL SPACE ACCESS INTO NEW CRAWL SPACE AREA THAT IS ACCESSIBLE FROM EITHER THE OUTSIDE OR FROM THE EXISTING CRAWLSPACE AREA, OTHERWISE CONTRACTOR IS TO PROVIDE (1� 1811x24" MINIMUM CRAWL SPACE ENTRANCE THROUGH MAIN LEVEL FLOOR FRAMING THAT ACCESSES NEW CRAWL SPACE AREA. a. A CERTIFICATE IS REQUIRED TO BE POSTED WITHIN 3' OF THE ELECTRICAL PANEL PER WSEC R401,3 AND INCLUDE THE FOLLOWING; PREDOMINATE R-VALUES, U-VALUES OF FENESTRATION, RESULTS FROM DUCT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TESTING, AND EFFICIENCIES OF HEATING/COOLING/WATER HEATING EQUIPMENT. p, A MIN OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN INTERIOR AND EXTERIOR LIGHTING FIXTURES MUST BE HIGH -EFFICIENCY LAMPS PER WSEC R404,1 INSULATION INSULATION'A•N REQUIREMENTS CLIMATE ZONE '40 5 AND MARINE-4 FENESTRATION U-FACTOR (k) 0.30 SKYLIGHT U-FACTOR (k) 0.50 GLAZED FENESTRATION SHGC (b,e) NR CEILING R-VALUE (k) 49 WOOD FRAME WALL R-VALUE (c) 21 INT MASS WALL R-VALUE (d) 21/21 FLOOR R-VALUE 30 BELOW -GRADE WALL R-VALUE (e,c) 10/15/21 INT + TB SLAB R-VALUE & DEPTH (9,h) 101 2FT FOR 51: 1 FOOT = 304,8 MM, CI = CONTINUOUS INSULATION, INT = INTERMEDIATE FRAMING. a, R-VALUES ARE MINIMUMS, U-FACTORS AND SHGC ARE MAXIMUMS. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE A101,4 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE. b, THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS, THE SHGC COLUMN APPLIES TO ALL GLAZED FENESTRATION, c, 1110/15/21 +TB" MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR OF THE WALL, OR R-15 CONTINUOUS INSULATION ON THE INTERIOR OF THE WALL, OR R-21 CAVITY INSULATION PLUS A THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL, 1110/15/21 +TB" SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL, "TB" MEANS THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT WALL, d, R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON GRADE FLOORS, SEE R402,2,9,1, e, THERE ARE NO SHGC REQUIREMENTS IN THE MARINE ZONE, f, RESERVED. 9, RESERVED. h, RESERVED. i, THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIOR OF THE MASS WALL, j, RESERVED. k, FOR SINGLE RAFTER- OR JOIST -VAULTED CEILINGS, THE INSULATION MAY BE REDUCED TO R-38, I, RESERVED. m, INT, INTERMEDIATE FRAMING) DENOTES STANDARD FRAMING 16 INCHES ON CENTER WITH HEADERS INSULATED WITH A MINIMUM OF R-10 INSULATION, n, LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE THICKNESS OF 3,5 INCHES ARE EXEMPT FROM THIS INSULATION REQUIREMENT, o, WHERE EXISTING FRAMING CAVITIES ARE EXPOSED DURING CONSTRUCTION, THE CAVITIES MUST BE FILLED TO FULL DEPTH WITH BATT INSULATION OR INSULATION HAVING AN EQUIVALENT NOMINAL R-VALUE OF R-15 AT 2x4 WALLS OR R-21 AT 2x6 WALLS PER WSEC 503,11 MECHAN ICAL/VENTI LATION AREAS TO BE EXHAUSTED EXHAUST RATES KITCHENS 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS BATHROOMS/TOILET ROOMS, LAUNDRY MECHANICAL EXHAUST ROOMS,INDOOR SWIMMING POOL ROOMS, SPA CAPACITY OF 50 CFM ROOMS, INTERMITTENT OR 20 CFM CONTINUOUS NUMBER OF BEDROOMS DWELLING UNIT FLOOR AREA (SQUARE FEET) 0-1 2-3 4-5 6-7 ;P-7 AIRFLOW IN CFM -1500 30 45 60 75 90 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 >7501 105 120 135 150 165 INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE FACTORS M1507.3,3�21 PRECENTAGE IN EACH 4-HOUR SEGMENT EMEMEM 1, LOCAL EXHAUST SHALL BE POVIDED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, INDOOR SWIMMING POOL, SPA, AND OTHER ROOMS WHERE WATER VAPOR OR COOKING ODOR IS PRODUCED, LOCAL EXHAUST SYSTEMS SHALL BE DESIGNED TO HAVE CAPACITY TO EXHAST THE MINIMUM AIR FLOW RATE DETERMINED IN ACCORDANCE WITH TABLE IRC M1507,4, • KITCHENS = 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS, • BATHROOMS/TOILET ROOMS, LAUNDRY ROOMS, INDOOR SWIMMING POOL ROOMS, SPA ROOMS = 50 CFM INTERMITTENT OR 20 CFM CONTINUOUS, • EXCEPTION: WHERE A RANGE HOOD OR DOWN DRAFT EXHAUST FAN IS USED TO SATISFY THE LOCAL EXHAUST REQUIREMENTS FOR KITCHENS, THE RANGE HOOD OR DOWN DRAFT EXHAUST SHALL NOT BE LESS THAN 100 CFM AT ,10 INCHES WATER GAUGE. • LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 2, WHOLE -HOUSE VENTILATION USING EXHAUST FANS MUST COMPLY WITH: • IRC M1507,3,2: 24HR INTERMITTENT WHOLE -HOUSE SWITCH TO BE INSTALLED TO CONTROL WHOLE -HOUSE FAN INTERMITTENTLY PER TABLE M1507,3,3�2�, LABEL TO BE AFFIXED TO THE CONTROL THAT READS "WHOLE HOUSE VENTILATION SEE OPERATING INSTRUCTIONS1" OPERATING INSTRUCTIONS SHALL BE PROVIDED BY INSTALLER, • IRC M1507,3,4,1: FAN MUST HAVE A FLOW RATING AT 0,25 INCHES WATER GAUGE • M1507,3,4,2: FANS WITHIN 4 FEET OF INTERIOR GRILLE SHALL HAVE A BONE RATING OF 1,0 OR LESS MEASURED AT 0,1 INCHES1 WATER GAUGE, • IRC M1507,344: EACH HABITABLE SPACE SHALL BE PROVIDED WITH OUTDOOR AIR INLETS OR OPERABLE WINDOWS WITH AN OPENABLE AREA NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF OUTDOOR AIR REQUIRED BY TABLE M1507.3,3�1�, WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING, 3, DUCTS MUST BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33 USING THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED, DUCT TIGHTNESS MUST BE VERIFIED BY EITHER A POST-CONSRUCTION TEST OR ROUGH - IN TEST PER WSEC R403,3,3, TOTAL LEAKAGE MUST BE LESS THAN OR EQUAL TO 4 CFM PER 100 SQ-FT OF CONDITIONED FLOOR AREA WHEN TESTED AT A PRESSURE DIFFERENTIAL OF 0,1" W,G, �25 PAS ACROSS THE ENTIRE SYSTEM, 4, PER IRC M1503,41 IF THE EXHAUST HOOD IN THE KITCHEN HAS A CAPACITY IN EXCESS OF 400 CFM, IT MUST BE MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A RATE OF APPROXIMATELY EQUAL TO THE EXHAUST TO THE EXHAUST AIR RATE, SUCH MAKE UP AIR SYSTEMS MUST BE EQUIPPED WITH NOT LESS THAN ONE DAMPER, EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS WHEN THE EXHAUST SYSTEM OPERATES, 5, WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ, INCHES SHALL BE PROVIDED IN THE CLOSET ENCLOSURE OR MAKEUP AIR SHALL BE PROVIDED BY OTHER APPROVED MEANS PER SMC 504,6, Vertical Fenestration (Windows and doors) Component Description Ref. U-factor W1- FIXED JWSEC 1 0.30 SAFETY GLAZING FOR EXISTING OPENING REPLACEMENT; ACTUAL SIZE Width Height Sill Qt. Feet inch Feet inch Feet Inch Area UA 1 g o 5 10 0 Zo 46.7 14.00 Sum of Vertical Fenestration Area and UA 46.7 14.00 Vertical Fenestration Area Weighted U = UA/Area 0.30 1, GLAZING IN DOORS: SAFETY GLAZING IS REQUIRED IN FIXED AND OPERABLE PANELS OF SWINGING, SLIDING, AND BIFOLD DOORS, SAFETY GLAZING IS NOT REQUIRED IN A DOOR IF THE GLAZED OPENINGS DO NOT ALLOW THEPASSAGE OF A 3 INCH SPHERE, OR THE GLAZING IN THE DOOR IS DECORATIVE, 2, GLAZING ADJACENT TO DOORS: GLAZING ADJACENT TO DOORS IS REQUIRED IN THE FOLLOWING LOCATIONS IF THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKING SURFACE; WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR IF GLAZING IS IN THE SAME PLANE AS THE DOOR, OR IF GLAZING IS IN A WALL PERPENDICULAR TO THE DOOR WITHIN 24 INCHES ON THE HINGE SIDE OF AN INSWING DOOR, SAFETY GLAZING IS NOT REQUIRED IF THERE IS AN INTERVENING WALL OR PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 3, GLAZING IN WINDOWS: SAFETY GLAZING IN WINDOWS IS REQUIRED IF THE INDIVIDUAL PANEL MEETS ALL OF THE FOLLOWING REQUIREMENTS: • EXPOSED AREA OF THE INDIVIDUAL PANEL IS GREATER THAN 9 SQUARE FEET, • THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18 INCHES FROM THE FLOOR • THE TOP EDGE OF THE GLAZING IS MORE THAN 36 INCHES ABOVE THE FLOOR, • THERE IS A WALKING SURFACE WITHIN 36 INCHES, MEASURED HORIZONTALLY, FROM THE GLAZING. EXCEPTIONS DECORATIVE GLAZING WHERE A HORIZONTAL RAIL CAPABLE OF RESISTING 50 PLF OF FORCE WITHOUT MAKING CONTACT WITH THE GLASS IS INSTALLED ON THE ACCESSIBLE SIDE OF THE GLAZING 34-38 INCHES ABOVE WALKING SURFACE, 4, GLAZING IN RAILINGS AND GUARDS: ALL GLAZING IN GUARDS AND RAILINGS, INCLUDING STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN -FILL PANELS, IS REQUIRED TO BE SAFETY GLAZING. 5, GLAZING AND WET SURFACE: GLAZING IN WALLS, ENCLOSURES, OR FENCES AROUND SHOWERS, BATHTUBS, POOLS, HOT TUBS, SPAS, SAUNAS, AND STEAM ROOMS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES FROM THE STANDING OR WALKING SURFACE IS REQUIRED TO BE SAFETY GLAZING, SAFETY GLAZING IS NOT REQUIRED WHERE THE GLAZINGIS MORE THAN 60 INCHES, HORIZONTALLY, FROM THE EDGE OF THE WATER, 6, REFER TO IRC SECTION 312,2 FOR ADDITIONAL REQUIREMENT. WINDOW & DOOR SCHEDULE NOTES; 1, XO = SLIDERS SH = SINGLE HUNG, DH = DOUBLE HUNG, FIX = PICTURE, C = CASEMENT 2, IF CONTRACTOR DECIDES TO REPLACE WINDOWS, THEY MUST MEET ENERGY PERFORMANCE STANDARDS, HEAT TREATMENT REQUIREMENTS AND EGRESS, 3, ALL WINDOWS SHALL BE NFRC CERTIFIED. 4, CONTRACTOR TO VERIFY EGRESS AND HEAT TREATMENT REQUIREMENTS WITH WINDOW & DOOR MANUFACTURER. 5, EGRESS WINDOWS SIZED FOR "MILGARD STYLE LINE" SERIES WINDOWS, CONTRACTOR TO VERIFY EGRESS REQUIREMENTS IF A DIFFERENT MANUFACTURER / MODEL IS CHOSEN, INSULATION CERTIFICATE ISEATTLEI CONTRACTOR SHALL COMPLETE AND POST AN INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION, AIR LEAKAGE ISEATTLEI: A WRITTEN REPORT OF THE TEST RESULTS, SHALL BE SIGNED BY THE TESTING PARTY AND PROVIDED TO THE BUILDING INSPECTOR, PRIOR TO CALL FOR FINAL INSPECTION, HIGH EFFICACY LAMPS A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS. RESUB Dec 01 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z 0 w U) U Z cn a W J o a. W N Q N wo i V, 40 YEN DESIGN INC. 206.432.1111 WWW.YENDES.COM APPROVAL STAMP ENGINEER STAMP J u.1 0 2 w J z w 0 LU U) 0 z OC G W T U) O z Q W z W z z J w U) O O 0 06 O 0 z W J 0 W U CO 0 N 0 00 rn u5 0 0 w JOB NO. 20-242 HALF SCALE 11x17 FULL SCALE 22x34 SHEET A1.1 51-10311 21_811 451_4111 191-51' 10'-10" 151-1211 61_92u —IN arljId- CP cV N ZD 19'-5'I _ 5'-6211 - 20'-511 PROPOSED UPPER FLOOR PLAN 22x34: SCALE 1/4" = 11-011 11x17: SCALE 1/8" = 11-011 PLAN KEYNOTES LEGEND 0 EXISTING WALL TO REMAIN 1. 2X6 STUD WALL, SEE DETAIL 3/A51 PROVIDE R-21 BATT INSULATION 0 EXISTING SUN ROOM ROOF & WALL FRAMING TO BE REPLACED o AND TO BE INFILLED PER 1/A4.1 0- w 2. EXISTING 6X12 RIDGE BEAM TO REMAIN NEW EXTERIOR 2X6 WALL, SEE DETAILS 1/A5.1 & 3/A5.1 U a FOR FRAMING AND INSULATION DETAILS, w 3. PROVIDE �N) 2X6 HF#2 RAFTERS @16" O.C. PROVIDE 0 a w N LUS HANGER @RIDGE, FILL ROOF CAVITY W/ R-38 ■ ■ EXISTING BEAM CLOSED CELL SPRAY FOAM. a N EXISTING STRUCTURE TO BE REMOVED 4. PROVIDE 4X6 HF#2 HEADER ABOVE OPENING W/ j2)2X > TRIMMER �2�2X STUD AT EACH END. - n INDICATES REFERENCE TO KEYNOTES SEE KEYNOTES ON W C� THIS SHEET FOR BALANCE OF INFORMATION 5, EXISTING POST TO REMAIN. CONTRACTOR TO VERIFY DIRECT LOAD PATH TO EXISTING FOUNDATION EF EXHAUST FAN �INTERMITTENT� 50 CFM UA.O. BELOW, IF ADEQUATE FOUNDATION IS NOT PRESENT PROVIDE 24" SQ. X 8" THICK FOOTING REINF. WITH SEE DOOR AND WINDOW SCHEDULE ON SHEET All FOR I2I #4 EACH WAY. SEE 4/A5.1 FOR BALANCE OF INFO. ® DETAILED INFO. SEE 2/A5.1 FOR FRAMING INFO. 6, EXISTING DOOR & TRANSOM WINDOW TO REMAIN GENERAL NOTES YEN DESIGN INC. A. PLANS MUST BE APPROVED BY THE GOVERNING BUILDING OFFICIAL OR PROFESSIONAL ENGINEER PRIOR TO WORK COMMENCING, I I SUN ROOM i DINING I I KITCHEN I I I I I I I I FIREPLACE I I I I I I I I r% A TI 1 i B. CONTRACTOR TO VERIFY ALL STRUCTURAL LOAD PATHS AND 206.432.1111 EXISTING SHEAR / BRACED WALL LOCATIONS BEFORE REMOVING WWW•YENDES.COM ANY WALLS, STRUCTURAL DEVIATIONS FROM THE PLAN SHOULD BE VERIFIED BY A STRUCTURAL ENGINEER OR BUILDING APPROVAL STAMP INSPECTOR, YEN DESIGN IS TO BE CONTACTED IF ACTUAL EXISTING FRAMING CONDITIONS VARY FROM PLAN ASSUMPTIONS AFTER CEILING WALL COVERINGS ARE REMOVED, C. SEE SHEET All FOR COMMON CODE REQUIREMENTS. D. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND PLACED IN PROXIMITY TO SLEEPING AREAS, E. SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND WITHIN EACH SLEEPING AREA. DIRECT WIRING REQUIRED. I ENGINEER STAMP F. VERIFY WINDOW & DOOR ROUGH OPENING SIZES WITH WINDOW & DOOR MANUFACTURER, G. ALL DIMENSIONS TO STUD WALL. H. CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION. I. CONTRACTOR TO DETERMINE & VERIFY ALL WASTE DIVERSION REQUIREMENTS PER THE LOCAL JURISDICTION. CONTRACTOR MAY BE REQUIRED TO REQUEST LEER REPORTS FROM RECEIVING FACILITIES. J. DOORS WITHOUT PLACEMENT DIMENSIONS WILL BE 3" OFF WALL OR ON CENTER, AS APPROPRIATE. K. CONTRACTOR TO VERIFY EXHAUST POINTS ARE NOT LESS THAN 3' FROM PROPERTY LINES, 3' FROM OPERABLE OPENINGS INTO THE BUILDING, AND 10' FROM MECHANICAL AIR INTAKES. L. EACH HABITABLE SPACE SHALL BE PROVIDED WITH OPERABLE WINDOWS WITH AN OPERABLE AREA NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF OUTDOOR AIR, WINDOW IS TO HAVE SCREEN AND SHALL BE CONTROLLABLE AND SECURABLE. EXISTING UPPER FLOOR PLAN 22x34: SCALE 1/8" = 11-011 11x17: SCALE 1/16" = 11-011 P'1 r !1 11 / / 11 A RESUB Dec 01 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT w J w Q oZ Lu w O o a p z U m a 0 O w w z 00 o 0 u� Lf7 >- mop } z w v Lr) 'oqo o a 00 v / Z J n O O H 0L LLu o— n JOB NO. 20-242 HALF SCALE l lxl7 FULL SCALE 22x34 SHEET A2.1 19'-5" i _ 25'-11211 PLAN KEYNOTES LEGEND 0 EXISTING WALL TO REMAIN 1. POST ABOVE EXISTING SUN ROOM TO BE INFILLED 2. EXISTING POINT LOAD FROM POST ABOVE, NEW EXTERIOR 2X6 WALL. SEE DETAILS 1/A5,1 & 3/A5.1 CONTRACTOR TO VERIFY DIRECT LOAD PATH TO FOR FRAMING AND INSULATION DETAILS. BEAM BELOW. IF ADEQUATE FOUNDATION IS NOT PRESENT PROVIDE 24" SQ X 8" THICK FOOTING ■ ■ EXISTING BEAM REINF. WITH I2J #4 EACH WAY. SEE 4/A5,1 FOR BALANCE OF INFO. _ _ _ _ = EXISTING STRUCTURE TO BE REMOVED 3, EXISTING BEAM TO REMAIN INDICATES REFERENCE TO KEYNOTES SEE KEYNOTES ON THIS SHEET FOR BALANCE OF INFORMATION N EF EXHAUST FAN �INTERMITTENTJ 50 CFM U.N.O. i F- O SEE DOOR AND WINDOW SCHEDULE ON SHEET A1,1 FOR DETAILED INFO. SEE 2/A5,1 FOR FRAMING INFO. GENERAL NOTES A. PLANS MUST BE APPROVED BY THE GOVERNING BUILDING OFFICIAL OR PROFESSIONAL ENGINEER PRIOR TO WORK COMMENCING, B. CONTRACTOR TO VERIFY ALL STRUCTURAL LOAD PATHS AND EXISTING SHEAR / BRACED WALL LOCATIONS BEFORE REMOVING ANY WALLS, STRUCTURAL DEVIATIONS FROM THE PLAN SHOULD BE VERIFIED BY A STRUCTURAL ENGINEER OR BUILDING INSPECTOR, YEN DESIGN IS TO BE CONTACTED IF ACTUAL EXISTING FRAMING CONDITIONS VARY FROM PLAN ASSUMPTIONS AFTER CEILING WALL COVERINGS ARE REMOVED, C. SEE SHEET A1,1 FOR COMMON CODE REQUIREMENTS. D. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND PLACED IN PROXIMITY TO SLEEPING AREAS, E. SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND WITHIN EACH SLEEPING AREA. DIRECT WIRING REQUIRED. F. VERIFY WINDOW & DOOR ROUGH OPENING SIZES WITH WINDOW & DOOR MANUFACTURER. N � SIN N 0 �Id u, 0 U° G. ALL DIMENSIONS TO STUD WALL. H. CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION. I. CONTRACTOR TO DETERMINE & VERIFY ALL WASTE DIVERSION REQUIREMENTS PER THE LOCAL JURISDICTION. CONTRACTOR MAY BE REQUIRED TO REQUEST LEED REPORTS FROM RECEIVING FACILITIES. J. DOORS WITHOUT PLACEMENT DIMENSIONS WILL BE 3" OFF WALL OR ON CENTER, AS APPROPRIATE. z 0 Lu U) U Z cn Q W J 0 a CD W N Q N o YEN DESIGN INC. 206.432.1111 WWW.YENDES.COM APPROVAL STAMP alolle3ul:10 91r_I AIN K. CONTRACTOR TO VERIFY EXHAUST POINTS ARE NOT LESS THAN 3' FROM PROPERTY LINES, 3' FROM OPERABLE OPENINGS INTO El THE BUILDING, AND 10' FROM MECHANICAL AIR INTAKES. a�IlqF L. EACH HABITABLE SPACE SHALL BE PROVIDED WITH OPERABLE J Q WINDOWS WITH AN OPERABLE AREA NOT LESS THAN 4 SQUARE O z INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF o CN OUTDOOR AIR, WINDOW IS TO HAVE SCREEN AND SHALL BE w O o CONTROLLABLE AND SECURABLE. m Q z U Q 0 O � 2 w w z 00 o 0Fn Lo -J < p w Lo :E GARAGE o a 0b cn= OOqo w N N 19'-5211 51-611 201-511 EXISTING BASEMENT PLAN 22x34: SCALE 1/4" = 1'-0" 11x17: SCALE 1/8" = 1'-0" Z J n Z LLu 75 Lu U) 00 M� ( V Z U) x Lu JOB NO. 20-242 RES U B HALF SCALE 11x17 FULL SCALE 22x34 Dec 01 2020 CITY OF EDMONDS SHEET DEVELOPMENT SERVICES DEPARTMENT A2.2 STRUCTURAL ELEMENTS ARE FOR REFERENCE ONLY, IF DISCREPANCES OCCUR STRUCTURAL DRAWINGS GOVERN DESIGN, RBC CLIP SPACED @ 24"o/c BOUNDARY NAILING FULL DEPTH BLKG ROOF DRIP EDGE FLASHING TO BE INSTALLED OVER GUTTER 1x8 FASCIA HEADER PER PLAN FIN. GRADE F- COMP, ROOFING OVER 15# FELT OR 3-TAB ROOFING OVER 30# FELT ROOF SHEATHING PER PLAN 12 TO MATCH EXISTING. H1 TIE AT EA RAFTER CONT, DOUBLE TOP PLATE w/ 48" LAP SPLICE, DOUBLE TOP PLATE R-10 RIGID INSULATION ^x6 STUDS @ 16"o/c RIDGE CAP TC "" ^ T' " I EXISTING 6X TO NEW Rol I L1\1.1 IV UL- CONNECTED TO EXISTING RIDGE BEAM WITH LUS HANGERS, NEW 2X6 RAFTERS @16" O,C, NEW RAFTERS TO BE INSULATED WITH R-38 CLOSED CELL SPRAY FOAM, UNVENTILATED ROOFI LIVING SPACE AEI 2X SILL PLATE AEI 2X JOIST z 0 w U) U Z cn W J o a CD W N a N o 0 o i ", lo YEN DESIGN INC. 206.432.1111 WWW.YENDES.COM APPROVAL STAMP alolle3ikil:1 431FO► iN IIIIII w Q IIIII I O z IIIIII ______________ —� 2 o II Xi O CD II II AEI 2X STUD WALL II J Q z Q z O � ~ z Q II o w } O } o II E o I I II w N LL w_ Lo 0 III Q 00 cn�w LIVING SPACE AEI CONC, WALL IEI SLAB ON GRADE a --------------- aE a �11El CONC. STEM WALL NEW EXTERIOR WALL AND RAFTER SECTION RESUB Dec 01 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z O U Lu CD Z 0 J_ Z) m JOB NO. 20-242 HALF SCALE llxl7 FULL SCALE 22x34 SHEET A4.1 SCALE: 1 "=1'-0" OPENING TYP. OPENING FRAMING SCALE: 1 /2"=1'-0" 0 0 EQ, u EQ, z IIIIIII I II1 � -III: 1 1 Lu Q z Q J J Lu a_ Pi J C� PER PLAN CONT DBL TOP PLATE HEADER PER PLAN FLUSH TO EXTERIOR CRIPPLE STUDS TO ALIGN w/ TRIMMERS FULL HEIGHT KING STUD OR POST PER PLAN OPTIONAL 2X TO MATCH WALL TYPE STUD WALL FRAMING 2X TRIMMER JACK STUD QTY PER HEADER SCHEDULE. FACE NAIL TO KING STUD DOUBLE 2X SILL PLATE CRIPPLE STUDS TO ALIGN w/ STUD WALL FRAMING :ING BELOW POST CB44 COLUMN BASE 1211 SONO TUBE FORM TO GRADE OR ABOVE N #4 VERT, DOWEL REINFORCEMENT PER PLAN POST/BEAM/FOOTING DETAIL A DOUBLE TOP PLATE R-10 RIGID INSULATION R-21 BATT INSULATION WINDOW SECTION SCALE: 1 "=1'-0" HEADER DOUBLE TOP PLATE R-21 BATT INSULATION 2x STUDS PER BUILDING SECTION R-21 BATT INSULATION LIVING SPA( WALL SHEATHING PER PLAN SIDING & MOISTURE BARRIER NEW EXTERIOR WALL ASSEMBLY SCALE: 1 "=1'-0" GENERAL NOTES SPREAD FOOTING 1211 WIDE x 611 TALL SPREAD FOOTING w/ j2)44 LONGITUDINAL BARS. STEM WALL O 611 THICK x 3011 TALL IMAXI STEM WALL w/ #4 HOR1 BARS @ 1011o/c & #4 w VERT. WALL TO FOOTING DOWELS @ 1811o/c Z W cn J ANCHOR BOLTS o a 5/8110 x 1011 ANCHOR BOLTS @ 4'-011o/c, PROVIDE ANCHOR BOLTS NOT LESS w N THAN 1211 FROM ENDS OF EA FOUNDATION SILL PLATE, PROVIDE 311 x 311 a N SQ, x 3/1611 THICK ANCHOR BOLT WASHERS, o FLOOR SHEATHING w 3/4" T&G APA RATED SHEATHING OR CDX PLYWOOD OR OSB w/ 10d @ 611o/c DIAPHRAGM NAILING AND 1211o/c FIELD NAILING. PLYWOOD SHALL BE LAID UP WITH FACE GRAIN PERPENDICULAR TO FRAMING MEMBERS BELOW AND END JOINTS SHALL BE STAGGERED, WALL SHEATHING 7/1611 APA RATED SHEATHING OR CDX PLYWOOD OR OSB w/ 8d @ 611o/c PANEL EDGE NAILING AND 1211o/c FIELD NAILING ROOF SHEATHING YEN DESIGN INC. 7/16" APA RATED SHEATHING OR CDX PLYWOOD OR OSB w/ 8d @ 611o/c DIAPHRAGM NAILING AND 1211o/c FIELD NAILING. PLYWOOD SHALL BE LAID UP WITH FACE GRAIN PERPENDICULAR TO FRAMING MEMBERS BELOW AND END JOINTS SHALL BE STAGGERED. 1 206.432. 1111 RESUB Dec 01 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT WWW.YENDES.COM APPROVAL STAMP AEel 1►1:1:1z4aI A A IN U) J W Q OZ 2 w O o Q C7 z U) rn Q O 3: w W z Fo- 0 cn Lo } mop } z Q 00 w czn -o'to Lu JOB NO. 20-242 HALF SCALE llxl7 FULL SCALE 22x34 SHEET A5.1 SCALE: 1 /2"=1'-0"