REVIEWED BLD2021-0552+WSEC+4.16.2021_2.29.00_AM+2149000RECEIVED BLD2021-0552 A _ _ . „ ---I simple I-leating system s¢e: wasnington state hN1 I This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Wasitiiiytvi, State Erieiyy Code (vVSEC) and A&*itF Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cM rffhV Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information Erica Kalapaca IFelipe Irizarry 9033 217TH ST SW, EDMONDS, WA 98026 contactCa@modernoengineering.com 425-999-4230 Heating System Type: OO All Other Systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions Edmonds Design Temperature Difference (AT) 46 J AT =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions U-0.30 Skylights Instructions Insulation Attic Instructions LR 49 Single Rafter or Joist Vaulted Ceilings Instructions No Vaulted Ceilings in this project. Above Grade Walls fsee Figure 11 Instructions R-211ntermediate � Floors Instructions No Floors above unconditioned spaces. � Below Grade Walls (see Figure 1) LJ Select R-value Slab Below Grade fsee Figure 1) R-10 Fully insulated Slab on Grade (see Figure 1) Instructions R-10 Fully Insulated � J Location of Ducts Instructions No Ducts � Figure 1. Above Grade 308 Conditioned Volume 8.0 2,464 U-Factor X Area = UA 0.300 48 14.40 U-Factor X Area = UA 0.50 --- U-Factor X Area = 0.026 308 U-Factor X Area U-Factor X Area 0.056 329 U-Factor X Area U-Factor X Area No selection 0 F-Factor X Length 0.303 F-Factor X Length 0.360 50 Sum of UA Duct Leakage Coefficient 1.00 UA 8.01 UA UA 18.42 UA UA UA UA 18.00 58.83 Envelope Heat Load 2,706 Btu / Hour Sum of UA x AT Air Leakage Heat Load 1,224 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 3,930 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 3,930 Btu / Hour Ducts in unconditioned sDace: sum of buildina heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 5,503 Btu / Hour Buildina and duct heat loss x 1.40 for forced air furnace Buildina and duct heat loss x 1.25 for heat DumD ;ES (07101113)