APPROVED ENG BLD PLN-BLD2021-0669+Architectural_Plan+5.13.2021_10.51.14_AM+2195025I I m Hardware and fasteners in contact with
preservative -treated wood shall be of ■
' hot -dipped zinc galvanized steel, I
stainless steel, silicon bronze or copper.
.In the absence of manufacturer's recommendations
Ia minimum of ASTM A 653 type G185 zinc -coated I
galvanized steel, or equivalent, shall be used. ■
LIRC R317.3.1 IBC 2304.10.5.1 I
-------------------
City of Edmonds
Building Department
APPROVED Plans
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
FP
1
fGROUND REVISION PLAN
City
Of Edmonds
Building Department
Work
-------------------------
DECK
---------------
Address
1017 9TH AVE S
Owner
STENCHEVER
Approved Date
---------------------------------
------------------------------------------------
05/26/2021
Building Officiale&#V;f_Mai
Permit Number
------------------
BLD2021-0669
I'A
APPROVED
BY PLANNING
Jun 02 2021
EXISTING 1 1 TINOTES
A. FIELD VERIFY ALL EXISTING UTILITY LOCATIONS PRIOR TO
STARTING DEMOLITION, EXCAVATION, AND
CONSTRUCTION! DIAL 811: CALL -BEFORE -YOU -DIG
B. EXISTING DECK, COLUMNS, GUARDRAILS, AND CANOPY
TO REMAIN
C. CONTRACTOR CONFIRM CONDITION AND WATER -TIGHTNESS
OF EXISTING LEDGER, FLASHINGS, SIDING AND WALL
FRAMING, AND REPAIR AS NEEDED ENTIRE LENGTH
D. EXISTING WINDOWS TO REMAIN
E. EXISTING GLAZED DOORS TO REMAIN
F. EXISTING GARAGE DOOR TO REMAIN
G. REMOVE EXISTING PAVING AND STEPS
H. REMOVE EXISTING DECK, STAIRS, COLUMNS, AND
FOOTINGS WITHOUT DISTURBING EXISTING UTILITIES
I. EXISTING DECK TO REMAIN, PROVIDE TEMPORARY SHORING,
THEN MODIFY FRAMING AND GUARDRAILS AND ATTACH TO
NEW DECK CONSTRUCTION
J. MODIFY EXISTING ROCKERY AT NEW COLUMNS AND FOOTINGS
K. ADD NEW ROCKERY TO FILL GAP WHERE EXISTING STEPS
HAVE BEEN REMOVED
L. NEATLY CUT EXISTING PAVING AT NEW FOOTING LOCATIONS
M. EXISTING DOWNSPOUT TO REMAIN
12
Dp�v `® l 7 `7 5,
err AA o 0, 7Col
`::>172t� r-_'�5VI - 6- 11-57-
EASEMENT RR5& UT4T1E9
PER OO R
RECORDING N0. 1706742
N w37'15' W-17851'- AM, SEE JOINT MN1NTERANCE AOREPJAENT RECORDING NO. 870611014/
EP
EASEMENT INGRESS, EGRESS & UMMES
PER DEED RECORDED iJNUER $
RECORDING ND.'1695549 (PAR 6)
148.51' .� I N 88'37'tb' W-148.51'
EASEMENT INGRESS. EVESS& UT9.f(1E5 ; I �{� FOR PUSUC VILFTY WM(CT
PER DEED RECORDED U RECORDING NO.. 554 A) o NO. 1. OF SNONOMIAND GENERAL
s ',EEEpHONE COMPANY
OF THE NORTH4YESf, INC.
t.1 RECOR6M7G ND. 2276076EWP
/� 1
N 8637' 15 W-178.51' V
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
OWNER/CONTRACTOR IS RESPONSIBLE FOR
EROSION CONTROL AND DRAINAGE
Applicant shall repair/replace all
ENGINEERING DIVISION
damage to utilities or frontage
improvements in City right-of-way
APPROVED AS NOTED
per city standards that is caused or
occurs during the permitted project.
1II
Jdl W 4AJm ,mt 06/01 /2021
PROJECT
INFORMATION
SCOPE: NEW DECK AND ASSOCIATED MODIFICATIONS TO
EXISTING DECK
ADDRESS: 1017 9TH AVE S EDMONDS, WA 98020-3909
PARCEL NUMBER: 27032500109600
LEGAL DESCRIPTION PER COUNTY (SEE SURVEY FOR
COMPLETE LEGAL): SEC 25 TWP 27 RGE 03RT-183C-1)
ALL TH PTN SW1/4 NE114 DAF COM SW COR SD SUB
TH S 88*54 23E ALG S LN SD SUB 30FT TH N00*30 35E
PLW W LN SD SUB 1078.82FT TH S88*52 27E 148.51 FT TO
TPB TH CONT S88*52 27E 148.51 FT TH S00*31 55W 83FT
TH N88*52 27 W 148.49FT TH N00*31 15E 83FT TPB
TOWNSHIP: 27 RANGE: 03 SECTION: 25 QUARTER: NE
ZONING: RS-10, MAXIMUM SITE COVERAGE: 35%
SETBACKS:
........................................... PER COMMUNICATIONS WITH BRAD SHIPLEY OF THE CITY
The City of Edmonds has OF EDMONDS: FOR THIS FLAG LOT REQUIRED SETBACK
IS 10 MINIMUM FROM PROPERTY LINES AND ACCESS
adopted the 2018 International EASEMENTS, WHICH WE HAVE PROVIDED
codes, with the exception of PER COMMUNICATIONS WITH NATALIE GRIGGS OF THE CITY
the International plumbingW.
OF EDMONDS: NO SETBACK IS REQUIRED FROM UTILITY
EASEMENTS, THOUGH WE HAVE PROVIDED ONE
code. The city has adopted the
2018 Uniform Plumbing Code. % SITE COVERAGE:
SITE: SF: 0.27 ACRE X 43,560 SF/ACRE = 11,761.2 SF
EXISTING HOUSE FOOTPRINT. 1,372 SF
PROPOSED DECK (NO COVER): 564 SF
EXISTING DECK (PARTIAL COVER): 358 SF
PROPOSED SITE COVERAGE: 2,294 SF = 19.5% (OK, < 35%)
■
■
CODE COMPLIANCE
/COMPLY IN FULL WITH CURENT CODES
LASW
ROM
-..
347
347.1
E A+VEGHT ! ROC!(
7.5
3A7.9'.
N
¢ ��
v
l e
x
sG
3474
1 AY.n 06
20 OL
I;
J�rO✓w
NOUSE f
347.4
N
/4P
107]
Sly, AVE g h
,�
`gyp '7 `tsi
'PAC UNIT `b01YL c.Y. '
'
F.
50 OL...
+��+..��
YD
t('�'�
34
1
1
19*
��S
Ham•
I FBI. FLO
R
1OR
IA�sy
��I�
�
�
t
ry �s 171N.
wc�
�i+
N W37'15' W-148.49'
SITE PLAN
fllO
1
w j
x�
CENC 4
s4 0.1• E
¢W " 17979"REW & CAP i
0.72i X 1.04E. OF MC
POSMO.N
2
onyx
4
�Y �b
n
_ .__..._ .... _. .
•.>
iN0. 1/2' REM & CAP
.. ..
•..
'LSA 22989'"
0.1TE. OF
... . ....... .. .....
CALC POS[ifON
NwTNc
Vl4O
2015 INTERNATIONAL BUILDING CODE
2015 INTERNATIONAL RESIDENTIAL CODE
2015 INTERNATIONAL MECHANICAL CODE
2015 INTERNATIONAL FUEL GAS CODE
2015 INTERNATIONAL FIRE CODE
2015 INTERNATIONAL EXISTING BUILDING CODE
2015 INTERNATIONAL PROPERTY MAINTENANCE CODE
2015 ICC PERFORMANCE CODE
2015 WASHINGTON STATE ENERGY CODE
2015 UNIFORM PLUMBING CODE
EDMONDS COMMUNITY DEVELOPMENT CODE TITLE 19
WASHINGTON STATE AMENDMENTS TO ICC CODES
DRAWING INDEX
- 1 ARCHITECTURAL CODE, VICINITY MAP, SITE PLAN
A - 2 ARCHITECTURAL DECK PLANS, ELEVATIONS, NOTES
A - 3 ARCHITECTURAL GENERAL NOTES, DETAILS
S 1.1 STRUCTURAL GENERAL NOTES
2.1 STRUCTURAL DECK PLANS
.1 STRUCTURAL DETAILS
SURVEY
E
3
U
w
L
E u
cc
U
T
�E
RECEIVED
May 17 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
4
Awl
_
i
t
1
lw_z
0
N
0
Emergency escape windows under decks and porches.
Emergency escape windows are allowed to be installed under decks and porches
IIIEST ELEVATION provided the location of the deck allows the emergency escape window to be fully
opened and provides a path not less than 36 inches in he_ig_ht_,_'36" in width and no
mnnm than RO" i length r,F ani n fri n xinrri nr rni iin*?nlq ipr, P*ii n '? A
I ontj
of
IN
M
-- - — --------- . . .........
SOUTH ELEVATION
DECK CONSTRUCTION NOTES
AA. FIELD VERIFY ALL EXISTING UTILITY LOCATIONS PRIOR TO
STARTING DEMOLITION, EXCAVATION, AND
CONSTRUCTION! DIAL 811: CALL -BEFORE -YOU -DIG
BB. EDGE OF NEW DECK
CC. STAINLESS STEEL (SS) CONNECTERS, FITTINGS, AND
FASTENERS TO BE USED TYPICALLY AT ALL LOCATIONS
DD. REINFORCED CONCRETE FOOTINGS PER STRUCTURAL,
FIELD VERIFY FOOTINGS TO LOCATE 12" MINIMUM BELOW
UNDISTURBED SOIL
EE. PRESSURE TREATED COLUMNS PER STRUCTURAL, STAINED
FINISH TO MATCH EXISTING
FF. PRESSURE TREATED BEAMS PER STRUCTURAL, STAINED
FINISH TO MATCH EXISTING, WITH SELF -HEALING
SELF -ADHERED MEMBRANE AT ALL BEAM TOP SURFACES
AND EDGES
GG. PRESSURE TREATED JOISTS AND BLOCKING PER STRUCTURAL,
STAINED FINISH TO MATCH EXISTING, WITH SELF-SEALING
SELF -ADHERED MEMBRANE AT ALL JOIST AND BLOCKING
TOP SURFACES AND TOP EDGES
HH. PRESSURE TREATED 2 X1 2 AND BLOCKING, STAINED FINISH TO
MATCH EXISTING, WITH SELF -HEALING SELF -ADHERED
MEMBRANE AT ALL JOIST AND BLOCKING TOP SURFACES AND
TOP EDGES
11. STAINLESS STEEL X-BRACING SYSTEM PER STRUCTURAL,
WITH ALL NECESSARY HARDWARE INCLUDING SS CABLES,
SS SHOULDER EYEBOLTS, SS THIMBLES, SSTURNBUCKLES,
SS WIRE ROPE CLIPS, SS CONNECTORS, ETC.
FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION.
JJ. TREX COMPOSITE DECKING WITH TREX HIDDEN SS FASTENERS,
WHICH AUTOMATICALLY SPACE DECKING TO PROVIDE
1/4" GAPS FOR DRAINAGE. MATCH EXISTING DECK HEIGHT
AGAINST HOUSE, AND SLOPE DECK 1/8" PER FOOT
AWAY FROM HOUSE.
KK. STAINLESS STEEL GUARDRAIL WITH WOOD TOP CAP, 1 1/2"
SQUARE SS TUBE PER STRUCTURAL, BRUSHED STAINLESS
FINISH, STAINED WOOD TOP CAP TO MATCH EXISTING.
LL. STAINLESS STEEL CABLE RAILS, SPACED 3.2" OC MAX, WITH
STAINLESS STEEL SWAGED FITTINGS MATCHING EXISTING.
FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION.
MM. REPAIR PAVING TO MATCH EXISTING ADJACENT
NN. EXISTING INGRESS / EGRESS / UTILITIES EASEMENT PER
SURVEY
00. EXISTING UTILITIES EASEMENT PER SURVEY
PP. EXISTING DRIVEWAY
:5 Y
0
E 'I,
0 _y
-C
E 5 _u
0) > ru
Mr
.V)
rn
U
RECEIVED
May 17 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
s
McNICHOLS1 Perforated Metal f —
Round, Stainless Steel, Type 304, 16
Gauge (.0625" Thick), 314" Round o 1"
Staggered Centers, 51% Open Area
ITEM: 18 4OU6 94�
t!—
m
V"
x Y1, 4 — L, — — — -__
GUARDRAILS SHALL BE DESIGNED TO RESIST A
CONCENTRATED LOAD OF 200 POUNDS IN ANY
DIRECTION AT THE TOP OF THE GUARDRAIL. INF
COMPONENTS SHALL BE DESIGNED TO RESIST A
i HORIZONTAL LOAD OF 50 POUNDS OVER A ONE
■ SQUARE FOOT AREA. IRC R301.5.
iO-m—m—.—.—.—.—.—.—.—.—.—.—.—1
GUARDRAILS SHALL BE MIN. 36" IN HEIGHT WHERE THE
i ADJACENT SURFACE OR GRADE IS 30" OR MORE BELOW.
RAILINGS SHALL BE SPACED TO NOT ALLOW THE PASSAGE OF —
A 4" SPHERE. IRC R312.1 •
-rr
a
Oak
60T�, �477AI lNl�l
a
•� • . r •r is i r • r [ [ .� ♦ •riy r
job
no
r[ • [ .r[ [rr [r [� .[ ice[
�•� [ [ • • [ i • [ i•' •� ♦ • •
r
- � •• [ i [ • • • - •- A
7. CONTRACTOR [ • ■r•R TO STARTING
CONSTRUCTION, AND . ALL i
DIMENSIONS AND CONDITIONS,AND • ARCHITECT
r OF ANY DISCREPANCIES.
•
•. DRAWINGS AND SPECIFICATIONS
[ • ARE �.
COMPLIMENTARY;
. [lY CONFLICTS INFORM ARCHITECT t
T111ELY FASHION.
9. ALL DIMENSIONS TO BE OVERALL FROM FINISH FACE TO FINISH FACE UNLESS OTHERWISE NOTED.
11. CONFLICTS: IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR STANDARDS OF THE INSTALLATION,
#R THE MATERIALS SPECIFIED, DO NOT EQUAL OR EXCEED THE LAWS OR ORDINANCES THE LAWS OR
ORDINANCES SH[LL GOVERN. NOTIFYARCHITECT OF ALL •
TYPICAL.12. ALL HARDWARE, FITTINGS, FASTENERS, AND CONNECTORS TO BE STAINLESS STEEL AT ALL LOCATIONS
R DE ISOLATION BETWEEN MET[ AND PRESSURE TREATED
i •• PROVIDE
BEAMS,GALVANIC ISOLATION BETWEEN DISSIMILAR METALS SUCH AS EXISTING FLASHINGS.
13. ALL WOOD USED FOR THIS PROJECT SHALL BE PRESSURE TREATED. ALL CUT ENDS AND DRILLED HOLES
SHALL BE MULTI -COAT SEALED WITH COMPATIBLE TREATMENT ENTIRE SUPPORT FRAMING (COLUMNS,
•BLOCKING,lrir[ •. CAPS) SHALLPROTECTIVE SEALED . AND STAINED TO MATCH
DECK.EXISTING
14. EACH SUBCONTRACTOR RESPONSIBLE
s•: •.:r ANY DAMAGE
..1 1 TO ADJACENT WORK,
. AND SHALL
. REPAIR
SAID DAMAGE AT THEIR OWN EXPENSE.
15. CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT FOR LOCATIONS OF AfTT
SUPPLEMENTAL LIGHTING, ELECTRICAL OUTLETS, ETC. WHERE LOCATIONS ARE NOT INDICATED ON
i[
16. CONTRACTOR SHALL VERIFY THE SIZES AND LOCATIONS OF ALL OPENINGS FOR EQUIPMENT EQUIPMENT
PADS,BASES, STRUCTURAL•r•r AS WELL AS POWER, AND WATER OR DRAIN [ A •
BEFORE PROCEEDING
i THE WORK.
OR STRUCTURAL ENGINEER. GENERAL CONTRACTOR IS ENTIRELY RESPONSIBLE FOR ALL ASPECTS OF
PROJECT PREPARATION, CONSTRUCTION, AND COMPLETION, INCLUDING BUT NOT LIMITED TO, CODE
COMPLIANCE, INSPECTIONS,• • AND CERTIFICATE OF OCCUPANCY,•. •
METHODOLOGY,AND SITE AND • •, SAFETY
Install per manufacturers
p
s ecifications. Have all
.
manufacturer
documentation on site.
c o
u
O �'x u
U � y
Q�
Ud
<
>
v
n
U
O d
ar
L�
N;
3 6 3
U
RECEIVED
May 17 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
�4 - 3
CRITERIA
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE
DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (2015
EDITION).
2. DESIGN LOADING CRITERIA:
HANDRAILS AND GUARDS
GUARDRAILS/BALCONY RAILS CONCENTRATED LOAD . . . . . . . . . . 200 LBS
RESIDENTIAL - ONE AND TWO-FAMILY DWELLINGS
FLOOR LIVE LOAD . . . . . . . . . . . . . . . . . . . . . . . . 40 PSF
MISCELLANEOUS LOADS
DECKS . . . . . . . . . . . . . . . . . . . . . . . . 1.5 x AREA SERVED
DEFLECTION CRITERIA
LIVE LOAD DEFLECTION . . . . . . . . . . . . . . . . . . L/360
TOTAL LOAD DEFLECTION . . . . . . . . . . . . . . . . . . L/240
ENVIRONMENTAL LOADS
SNOW . . . . . . . . . . . Ce=1. 0, Is=1.0, Ct=1. 1, Pg=25 PSF, Pf=20 PSF
WIND . . . . . . . GCp i =0. 18, 110 MPH, RISK CATEGORY II, EXPOSURE "B"
EARTHQUAKE . . . ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
LATERAL SYSTEM: CANTILEVER TIMBER FRAME, Vs = 4.0 KIPS
SITE CLASS=D, Ss=1.266, Sds=0.844, S1=0.496, SD1=0.497,
Cs=0.563, SDC D, Ie=1.0, R=1.5
SEE PLANS FOR ADDITIONAL LOADING CRITERIA
3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS FOR BIDDING AND CONSTRUCTION. ARCHITECTURAL DRAWINGS ARE THE
PRIME CONTRACT DRAWINGS. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE
SPECIFICATION, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE
REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING.
ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH
DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK.
4. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND
DETAILS SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL
DIMENSION CONTROL IS DEFINED BY THE ARCHITECTURAL WALL SECTIONS, BUILDING
SECTION, AND PLANS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL
ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE
CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY
AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING
CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS
OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT,
SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO
THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE.
6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN
ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-14 "DESIGN LOADS ON
STRUCTURES DURING CONSTRUCTION".
7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE
ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR
CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS
REQUIREMENT.
8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO
DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO
REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. ALL
TYPICAL NOTES AND DETAILS SHOWN ON DRAWINGS SHALL APPLY, UNLESS NOTED
OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS
BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. WHERE TYPICAL
DETAILS ARE NOTED ON THE PLANS, THE SPECIFIED TYPICAL DETAIL SHALL BE
USED. WHERE NO TYPICAL DETAIL IS NOTED, IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO CHOOSE THE APPROPRIATE TYPICAL DETAIL FROM THOSE
PROVIDED OR REQUEST ADDITIONAL INFORMATION. THE CONTRACTOR SHALL SUBMIT
ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH RELATED
CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING PRODUCTION
AND FIELD USE.
9. ALL STRUCTURAL SYSTEMS, WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD
ERECTED, SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING,
DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS
PREPARED BY THE SUPPLIER.
GEOTECHNICAL
10. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE
ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR
APPROVED BY THE BUILDING OFFICIAL. IF SOILS ARE FOUND TO BE OTHER THAN
ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN.
FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT
FINISHED GRADE. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELOW
COLUMNS OR WALLS ABOVE.
BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND
PROVIDE FOR SUBSURFACE DRAINAGE.
ALLOWABLE SOIL PRESSURE . . . . . . . . . . . . . . . . . . . . . . 1500 PSF
LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) . . . . . . .55 PCF/35 PCF
ALLOWABLE PASSIVE EARTH PRESSURE (FS OF 1.5 INCLUDED). . . . . . . 300 PCF
COEFFICIENT OF FRICTION (FS OF 1.5 INCLUDED) . . . . . . . . . . . . . . 0.3
TRAFFIC SURCHARGE PRESSURE (UNIFORM LOAD) . . . . . . . . . . . . . 75 PSF
SEISMIC SURCHARGE PRESSURE (UNIFORM LOAD) . . . . . . . . . . . . . 7H PSF
General Structural Notes
THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS
RENOVATION
11. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE
COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING
CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES.
DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING
STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON
EXISTING FLOOR SYSTEMS TO 40 PSF.
12. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND
CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING
CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND
MUST BE VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND STRUCTURAL
ENGINEER IF EXISTING CONDITIONS DETERMINED DURING WORK VARY FROM THE
EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS.
13. CONTRACTOR SHALL CHECK FOR DRY ROT AT ALL AREAS OF NEW WORK. ALL ROT
SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS
DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT.
14 01►0
14. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE
WITH ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28-DAY
STRENGTH OF f'c = 3,000 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2
SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A
SLUMP OF 5" OR LESS. REQUIRED CONCRETE STRENGTH IS BASED ON THE DURABILITY
REQUIREMENTS OF SECTION 1904 OF THE IBC. DESIGN STRENGTH IS f'c = 2,500
PSI.
15. ALL CONCRETE WITH SURFACES EXPOSED TO WEATHER OR STANDING WATER SHALL BE
AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494,
AND C618. TOTAL AIR CONTENT FOR FROST -RESISTANT CONCRETE SHALL BE IN
ACCORDANCE WITH ACI 318-14, TABLE 19.3.2. 1 MODERATE EXPOSURE, F1.
16. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1),
GRADE 60, FY = 60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON
THE DRAWINGS SHALL BE GRADE 40, FY = 40,000 PSI. WELDED WIRE FABRIC SHALL
CONFORM TO ASTM A-185. SPIRAL REINFORCEMENT SHALL BE DEFORMED WIRE
CONFORM I NG TO ASTM A615, GRADE 60, FY = 60, 000 PSI.
17. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN
ACCORDANCE WITH ACI 315-99 AND 318-14. LAP ALL CONTINUOUS REINFORCEMENT
#5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT
ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40 BAR
DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN
ACCORDANCE WITH ACI 318-14, CLASS B. LAP ADJACENT MATS OF WELDED WIRE
FABRIC A MINIMUM OF 8" AT SIDES AND ENDS.
NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS
SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER.
18. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED
TO EARTH . . . . . . . . . . . . . . . . . . . . . . 3'
FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) . . . . 2"
FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER). . 1-1/2"
COLUMN TIES OR SPIRALS AND BEAM STIRRUPS . . . . . . 1-1/2"
SLABS AND WALLS (INT. FACE). . . GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4"
19. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL
BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED
RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL
ON WHICH IT IS PLACED (3000 PSI MINIMUM).
STEEL
20. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON:
A.AISC 360 AND SECTION 2205.2 OF THE INTERNATIONAL BUILDING CODE.
B.APRIL 14, 2010 AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND
BRIDGES AMENDED AS FOLLOWS: AS NOTED IN THE CONTRACT DOCUMENTS, BY THE
DELETION OF PARAGRAPH 4.4.1, AND REVISE REFERENCE FROM "STRUCTURAL
DESIGN DRAWINGS" TO "CONTRACT DOCUMENTS" IN PARAGRAPH 3.1.
C.SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS.
21. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
TYPE OF MEMBER ASTM SPECIFICATION FY
A.WIDE FLANGE SHAPES A992 50 KSI
B.OTHER SHAPES, PLATES, AND RODS A36 36 KSI
C.OTHER SHAPES AND PLATES A572 (GRADE 50) 50 KSI
(NOTED GRADE 50 ON PLANS)
D. PIPE COLUMNS A53 ( E OR S, GR. B) 35 KSI
E. STRUCTURAL TUBING A500 ( GR. B)
-SQUARE OR RECTANGULAR 46 KSI
-ROUND 42 KSI
-ANY SHAPE ASTM A1085 50 KSI
F.CONNECTION BOLTS A325-N
(3/4" ROUND, UNLESS SHOWN OTHERWISE)
22. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL CONFORM TO SECTION 10 OF
THE AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES.
23. ALL STEEL EXPOSED TO THE WEATHER OR IN CONTACT WITH GROUND SHALL BE
STAINLESS STEEL, UNLESS OTHERWISE NOTED,
24. ALL A-325N CONNECTION BOLTS NEED ONLY BE TIGHTENED TO A SNUG TIGHT
CONDITION, DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL PLIES IN A JOINT
ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEW IMPACTS OF AN IMPACT
WRENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCH.
25. ALL ANCHORS EMBEDDED IN MASONRY OR CONCRETE SHALL BE A307 HEADED BOLTS OR
A36 THREADED ROD WITH AN ASTM 563 HEAVY HEX NUT TACK WELDED ON THE
EMBEDDED END.
26.ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS AND SHALL
BE PERFORMED BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY
PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. ALL COMPLETE JOINT
PENETRATION GROOVE WELDS SHALL BE MADE WITH A FILLER MATERIAL THAT HAS A
MINIMUM CVN TOUGHNESS OF 20 FT-LBS AT -20 DEGREES F AND 40 FT - LBS AT 70
DEGREES F, AS DETERMINED BY AWS CLASSIFICATION OR MANUFACTURER
CERTIFICATION.
WOOD
27.FRAMING LUMBER SHALL BE S-DRY, KD, OR MC-19, AND GRADED AND MARKED IN
CONFORMANCE WITH WCLIB STANDARD "GRADING RULES FOR WEST COAST LUMBER NO.
17", OR WWPA STANDARD, "WESTERN LUMBER GRADING RULES 2011". FURNISH TO
THE FOLLOWING MINIMUM STANDARDS:
JOISTS (2X & 3X MEMBERS) HEM -FIR NO. 2
AND BEAMS MINIMUM BASE VALUE, Fb = 850 PSI
(4X MEMBERS) DOUGLAS FIR -LARCH NO. 1
MINIMUM BASE VALUE, Fb = 1000 PSI
BEAMS (INCL. 6X AND LARGER) DOUGLAS FIR -LARCH NO. 1
MINIMUM BASE VALUE, Fb = 1350 PSI
POSTS (4X MEMBERS) DOUGLAS FIR -LARCH NO. 2
MINIMUM BASE VALUE, Fc = 1350 PSI
(6X AND LARGER) DOUGLAS FIR -LARCH NO. 1
MINIMUM BASE VALUE, Fc = 1000 PSI
STUDS, PLATES & MISC. FRAMING: DOUGLAS FIR -LARCH NO. 2
OR HEM -FIR NO. 2
28. GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH ASTM AND
ANSI/AITC STANDARDS. EACH MEMBER SHALL BEAR AN AITC OR APA-EWS
IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC OR APA-EWS
CERTIFICATE OF CONFORMANCE. ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR
COMBINATION 24F-V4, Fb = 2,400 PSI, Fv =265 PSI. ALL CANTILEVERED BEAMS
SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb = 2400 PSI, Fv = 265 PSI.
29. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT
IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND
CONCRETE OR MASONRY.
30. PRESERVATIVE TREATED WOOD SHALL BE TREATED PER AWPA STANDARD U1 TO THE USE
CATEGORY EQUAL TO OR HIGHER THAN THE INTENDED APPLICATION. TREATED WOOD
FOR ABOVE GROUND USE SHALL BE TREATED TO AWPA UC3B. WOOD IN CONTINUOUS
CONTACT WITH FRESH WATER OR SOIL SHALL BE TREATED TO AWPA UC4A. WOOD FOR
USE IN PERMANENT FOUNDATIONS SHALL BE TREATED TO AWPA UC4B.
31.FASTENERS AND TIMBER CONNECTORS USED WITH TREATED WOOD SHALL HAVE
CORROSION RESISTANCE AS INDICATED IN THE FOLLOWING TABLE, UNLESS OTHERWISE
NOTED.
WOOD TREATMENT CONDITION PROTECTION
HAS NO AMMONIA CARRIER INTERIOR DRY G90 GALVANIZED
CONTAINS AMMONIA CARRIER INTERIOR DRY G185 OR A185 HOT DIPPED OR
CONTINUOUS HOT -GALVANIZED
PER ASTM A653
CONTAINS AMMONIA CARRIER INTERIOR WET TYPE 304 OR 316 STAINLESS
CONTAINS AMMONIA CARRIER EXTERIOR TYPE 304 OR 316 STAINLESS
AZCA ANY TYPE 304 OR 316 STAINLESS
INTERIOR DRY CONDITIONS SHALL HAVE WOOD MOISTURE CONTENT LESS THAN 19%.
WOOD MOISTURE CONTENT IN OTHER CONDITIONS (INTERIOR WET, EXTERIOR WET, AND
EXTERIOR DRY) IS EXPECTED TO EXCEED 19%. CONNECTORS AND THEIR FASTENERS
SHALL BE THE SAME MATERIAL. COMPLY WITH THE TREATMENT MANUFACTURERS
RECOMMENDATIONS FOR PROTECTION OF METAL.
32.TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE"
BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-C-2019.
EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED
THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE
NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER FOR MAXIMUM LOAD
CARRYING CAPACITY. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
ALL 2X JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST
HANGERS.
WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR
BOLTS IN EACH MEMBER.
ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM)AS
MEMBERS CONNECTED.
33. WOOD FASTENERS
A.NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING
SPECIFICATIONS:
SIZE LENGTH DIAMETER
6d 2" 0. 113"
8d 2-1/2" 0. 131"
10d 3" 0. 148"
12d 3-1/4" 0. 148"
16d BOX 3-1/2" 0.135"
IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT
NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION)
FOR REVIEW AND APPROVAL.
NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE
DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED.
TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER AND
STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END.
B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS
UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD.
INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN
SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70
PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND
SMALLER LAG SCREWS.
A. NOTCHES ON THE ENDS OF SOLID SAWN JOISTS AND RAFTERS SHALL NOT EXCEED
ONE-FOURTH THE JOIST DEPTH. NOTCHES IN THE TOP OR BOTTOM OF SOLID SAWN
JOISTS SHALL NOT EXCEED ONE -SIXTH THE DEPTH AND SHALL NOT BE LOCATED IN
THE MIDDLE THIRD OF THE SPAN. HOLES BORED IN SOLID SAWN JOISTS AND
RAFTERS SHALL NOT BE WITHIN 2 INCHES OF THE TOP OR BOTTOM OF THE JOIST,
AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED ONE-THIRD THE DEPTH
OF THE JOIST.
35. WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE
PLANS:
A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE
MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC "TIMBER
CONSTRUCTION MANUAL" AND THE AWC "NATIONAL DESIGN SPECIFICATION FOR WOOD
CONSTRUCTION". MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM
TO IBC TABLE 2304.10.1. COORDINATE THE SIZE AND LOCATION OF ALL
OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS.
B. FLOOR FRAMING: PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. TOE -NAIL
JOISTS TO SUPPORTS WITH TWO 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH
HEADERS OR BEAMS WITH SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH
NOTES ABOVE. NAIL ALL MULTI JOIST BEAMS TOGETHER WITH TWO ROWS 16d @ 12"
ON -CENTER.
STRUCTURAL
ENGINEERING
2124 Third Avenue - Suite too - Seattle, WA 98121
p:2o6.443.6212 ssfengineers.com
934 Broadway - Tacoma, WA 98402
P:253•z84.9470 ssfengineers.com
Copyright 2021 Swenson Say Fag6t - All Rights Reserved
DESIGN:
LSD
DRAWN:
NHD
CHECKED:
LSD
APPROVED:
DJS
REVISIONS:
JURISDICTIONAL APPROVAL STAMP:
PROJECT TITLE:
Stenchever Deck
ARCHITECT:
RECEIVED
May 17 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ISSUE:
Permit
SHEET TITLE:
General
Structural
Notes
SCALE:
DATE:
January 18, 2021
PROJECT NO:
12670-2021-01
SHEET NO:
S1.1
F(N) FTG. SHALL NOT
SURCHARGE (E) WALL
I TYPICAL, THUS: I
NEW FTG. '
(E) WALL
f
3'4 sq. x14"dp. FOOTING
W/ (5)#5 EA. WAY BOT.,
TYP. (8) LOC'S.
I — 1
I I
I LJ I
I I
STEEL CROSS BRACING,
ABOVE, TYP.
TYP. @ (8) LOCS W/
BRACE ORIENTATION
& LOC. PER PLAN 12/S31 Ir
I
r
I LJ
I � �
I I
(E) FOOTING -I I
I I
L I
I - �
I I
(E) FOOTING -I I
I I
L I
J
I
I
I
;
; I
I
Foundation Plan
Scale: 1/4" = 1'-O" 7
(E) POST
BA410 (MAX)
z (STAINLESS STEEL)
o w typ. AT 410 BEAMS,
� (12) LOCS.
7/S3.1, 11/S3.1
7153.1
_ - TREATED GL -_,5 2412 8/S3.1
8/S3.1----___ -
I --
I
DTT2Z I o
(STAINLESS STEEL) < N C j o
----- ------
-------------
I
I
7/S3.1 I 7 IS
TREATED GL 5%I
2x12 I
\ I
\ � I
o I
X I
� I
10/S3.1 I
<----- -----
- ---------
02)
7/S3.1 - cc- I
I
L TREATED IL 51 7/S3.1 I
/2x12 I _
STEEL CROSS BRACING, I I S3.
TYP. (6) LOC'S.
CD
I I I
I
DTT2Z t o N I i S3.1
(STAINLESS STEEL)-\- �_ -�<
\- -------- - ---- --
c -
- -I 1
1 I
_ 7/S3.1 8/S3.1 I 7�S3.1
U Q
wo
8/S3.1 TRTED /-----
- 10/S3.1G1 5x12I
-I ao
P.T. 6x6 POST, TYP.
(8) LOC'S. W/ CCQ66SDS2.5
CAP (STAINLESS STEEL) &
CBSQ66-SDS2 (STAINLESS STEEL)
BASE
co`%
LUS210 HANGER —
(STAINLESS STEEL)
I�
w
t
E BEAM II
Legend
1 ® NEW STRUCTURAL WALL OR POST BELOW
U
--------- __ NEW STRUCTURAL WALL OR POST ABOVE
o L @»
Lai
N o '
EXISTING STRUCTURAL WALL OR POST ABOVE
0 ® EXISTING WALL OR POST BELOW
0 EXISTING STEM WALL & FOOTING
(E) LEDGER
— — — — —
F/- NEW CONCRETE PLINTH & FOOTING
L_ J
U210 HANGER
SPAN DIRECTION
(STAINLESS STEEL)
EXTENT OF JOISTS
DTT2Z
(STAINLESS STEEL)
NEW HEADER/BEAM PER PLAN
EXISTING HEADER/BEAM
HANGER
— — 10 HANGER
TAINLESS STEEL), tYP•
��.�.�.�.�.�.�.�.�.�.�.�.�.�.�.�.�.�.�.�■
TENSION TIES FOR LATERAL LOADS ARE REQUIRED FOR THE
T. 2x10 (min.)
' LEDGER TO STRUCTURE ATTACHMNT. HOLD DOWN OR TESION
LEDGER
DEVICE WITH A 1500# CAPACITY OR 750# CAPACITY HOLD DOWN
DEVICES IN 4 LOCATIONS EVENLY DISTRIBUTED ALONG THE
(E) DECK I^
DEMOLIAD
i DECK AND WITHIN 2 FT OF THE END. INSTALL ALL DEVICES PER i
_I
■ MANUFACTURERS INSTRUCTIONS. ■
DIZZ
( AINLESS STEEL)
CQ210-2-SDS HANGER
AINLESS STEEL)
k) WALL FRAMING /
EDGE OF BUILDING
(E) (2)2x10
FIELD VERIFY
(E)2x10 @ 16"oc
JOISTS, FIELD VERIFY
Framing Plan
Scale: 1/4" = 1'-O"
Plan Notes
1. REFER TO GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS.
2. DO NOT SCALE DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.
3. THE BOTTOM OF ALL EXTERIOR FOOTING SHALL BE 18" MINIMUM BELOW EXTERIOR GRADE.
4. TYPICAL NEW DECKING CONSISTS OF TREK DECKING PER ARCHITECT OVER JOISTS AND
BEAMS PER PLAN. FACE GRAIN PERPENDICULAR TO JOISTS AND BEAMS, UNLESS NOTED
OTHERWISE.
5. PROVIDE AC, ACE, PC, EPC, LPC, OR LICE COLUMN CAP AND BASE AT ALL BEAM TO COLUMN
CONNECTIONS UNLESS NOTED OTHERWISE.
6. MANUFACTURED LUMBER PRODUCTS (LSL, LVL, PSL, GL) SHALL BE INSTALLED WITH A
MOISTURE CONTENT OF 12% OR LESS. THE CONTRACTOR SHALL MAKE PROVISIONS DURING
CONSTRUCTION TO PREVENT THE MOISTURE CONTENT OF INSTALLED BEAMS FROM EXCEEDING
12%.
7. ALL POSTS ABOVE SHALL BEAR FULLY ON BEAMS OR POSTS BELOW AND SHALL HAVE FULL
CONTINUOUS BEARING THROUGH FLOORS TO FOUNDATION.
8. REFERENCE ARCHITECTURAL DRAWINGS FOR WATERPROOFING DETAILS AND REQUIREMENTS.
9. ALL CONNECTORS SHALL BE STAINLESS STEEL, U.N.O.
10. HANDRAILS PER TYPICAL HANDRAIL DETAILS PER 10/S3.1 AND 11/S3.2 OR APPROVED
ALTERNATE.
STRUCTURAL
ENGINEERING
2124 Third Avenue - Suite ioo - Seattle, WA 98121
p:2o6.443.6212 ssfengineers.com
934 Broadway - Tacoma, WA 98402
P:253.2$4.9470 ssfengineers.com
Copyright 2021 Swenson Say Faget - All Rights Reserved
DESIGN:
LSD
DRAWN:
NHD
CHECKED:
LSD
APPROVED:
DJS
REVISIONS:
JURISDICTIONAL APPROVAL STAMP:
PROJECT TITLE:
Stenchever Deck
ARCHITECT:
RECEIVED
May 17 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ISSUE:
Permit
SHEET TITLE:
Deck Plans
1/4" = P-0" U.N.O.
DATE:
January 18, 2021
PROJECT NO:
12670-2021-01
SHEET NO:
S2,01
zz
t■ ■ ■ ■ ■ ■ ■ ■ ■ ■�
ITENSION TIES FOR LATERAL LOADS ARE
REQUIRED FOR THE LEDGER TO STRUCTURE i
HOLD DOWN OR TESION DEVICE
IATTACHMNT.
WITH A 1500# CAPACITY OR 750# CAPACITY HOLD ■
(E) EXTERIOR WALL SHEATHING
(E) EXTERIOR WALL SHEATHING
DOWN DEVICES IN 4 LOCATIONS EVENLY I
DISTRIBUTED ALONG THE DECK AND WITHIN 2 FT
WATERPROOFING PER ARCH.
■ OF THE END. INSTALL ALL DEVICES PER I
; I MANUFACTURERS INSTRUCTIONS.
P.T. 2x LEDGER TO MATCH
■ ��� ■
DECK FRAMING (U.N.O.)
(E)
RIM OR BLOCKING
W/ (2) ROWS SDS'/4x3l/2
SCREWS @ 6"oc, STAGGERED
'
(E) JOISTS AND SHEATHING
IVI
IVI
IAI
IAI
JL
(E)
JOISTS AND SHEATHING
E
BEAM PER PLAN
/\
NO CONN. AT BEAM
TO RIM
(E)
BEAM/HDR. (where occurs)
(E) BEAM/HDR. (where occurs)
4" min. 6"oc
5" max.
SDS Screw Spacing Elevation
FOR CALLOUTS
IN COMMON
NOTE: LEDGER FASTENER SPACING
SEE 4/S3.1
MAY BE OFFSET UP TO 3" TO AVOID
INTERFERENCE W/ JOIST HANGER
1
2
3
4
BEAM PER PLAN
JOISTS PER PLAN
TREX DECKING
HDG THREADED ROD
TREX DECKING
PER ARCH. (1" THK. MAX)
AT DTT2Z CONN. PER PLAN
PER ARCH. (1" THK. MAX)
DTT2Z CONN. PER PLAN
HANGER PER PLAN
BRACE CONNECTION IN
CCQ COLUMN CAP
PERPENDICULAR DIRECTION
Xz
CCQ COLUMN CAP PER PLAN
(where ocurs)
McMASTER—CARR STAINLESS
3/4" STL. EYENUT W/
0
0`
. •
/4 0 THRD. ROD
_IC-4
varies (15• to 45°)
STAINLESS STL. LIFTING
- ---
THIMBLE FOR 1/2" 0
varies (15• to 45•)
'
WIRE ROPE--
(4) STAINLESS STL. CAST
�,
/2"x3"sq STAINLESS
WIRE ROPE CLAMPS EA.
\
STEEL WASHER
END, TYP. TORQUE EA.
POST PER PLAN
��
,oP� Q" CLAMP TO 45ft—lbs.
�V
(9'-6" MAX HT. ALLOWED)
POST PER PLAN
�,� PER MFR. REQMNTS.
(9 —6 MAX HT. ALLOWED)
•
1/2"0 STAINLESS STL. FLEXIBLE
BRACE CONNECTION IN
DEAD END
\ WIRE ROPE (607),
PERPENDICULAR
DIRECTION
PROVIDE TURNBUCKLE IN
(where ocurs)
LIVE END
SPAN OF WIRE TO ALLOW
WIRE TO BE RETIGHTENED
FOR CALLOUTS
// AS REQ'D. MAX ALLOWABLE
IN COMMON
CABLE LOAD IS 3000lbs.
SEE 8/S3.1
Typical Brace
Top Connection
- E-W Braces 7
Typical Brace
Top Connection - N-S Braces 8
POST, PLINTH, & FTG.
THRD ROD INSIDE TIES
TOP RAIL & CONN.
J '
PER ARCH
CABLE/WIRE ROPE
CONN. PER 8/S3.1
Plan dew
TREK DECKING
McMASTER—CARR
PER ARCH. (1" THK. MAX)
STAINLESS
4 STL. EYENUT W/
POST PER PLAN
DECK JOISTS PER
STAINLESS STEEL
DECK GUARDRAIL
a
E
TREK DECKING
3
/4 0 THRD. ROD
(9'-6" MAX HT. ALLOWED)
PLAN
HSS 11/2x11/2x1/4
�
PER ARCH. (1" THK. MAX)
U—BAR TO MATCH &LAP
SIMPSON CBSQ POST
BEAM PER PLAN
DTT2Z EA. GUARDRAIL
W/ VERT. REINF., (4) TOTAL,
BASE PER PLAN
POST (STAINLESS STEEL)
AT CONTR OPTION, PROVIDE
(2) 1/2" 0 HDG BOLTS
PROVIDE (4)#5x SL IN LIEU
_____ _
s
EA. GUARDRAIL POST
OF U—BARS AND VERTS
00
----------- -
N--------- -
•
CV
--- •.•
/ / / / / / / /
/ / / / / /
N_ z
`V
18"0 CONC. PLINTH W/ -
(2) BAYS FULL —DEPTH
ALIGN 2x10 JOIST
(8)#5 x L VERT. &
\\� Plan -
CD
2x BLKG. W/ A35 EA.
#4 x (D @ 6" oc W/
P.T. 2x12 min.
END OF EA. BLOCK
R� 4" TO MATCH
(3)#4 x 0 IN TOP!\//�\//�\/��\���/�//��/\/��
POST DIMS
6 OF PLINTH /\\//
; 4 5 /\
2
FOOTING SIZE &
FOR CALLOUTS
POST BEYOND PER PLAN\\/\
��\' REINF. PER PLAN
IN COMMON
SEE S3.1 11
/
/ / r
>/2 x4 sq WASHER//\\j/\//\//\//\//\//\//\//\//\//
/00000/
9
10
11
12
Typical Brace Base Connection
STRUCTURAL
ENGINEERING
2124 Third Avenue - Suite ioo - Seattle, WA 98121
p:2o6.443.6212 ssfengineers.com
934 Broadway - Tacoma, WA 98402
P:253.2$4.9470 ssfengineers.com
Copyright 2021 Swenson Say Faget - All Rights Reserved
DESIGN:
LSD
DRAWN:
NHD
CHECKED:
LSD
APPROVED:
DJS
REVISIONS:
JURISDICTIONAL APPROVAL STAMP:
_
PROJECT TITLE:
Stenchever Deck
_
ARCHITECT:
RECEIVED
May 17 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ISSUE:
SHEET TITLE:
Permit
Details
SCALE:
3/4" = 1'-0" U.N.O.
DATE:
January 18, 2021
PROJECT NO:
12670-2021-01
SHEET NO:
S34,1