Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ENG2021-0425 ROW PERMIT
RIGHT OF WAY EUC PERMIT PERMITNUMBER, City of Edmonds ...0i 1 1ii www.cityofedmonds.gov Description: PUD-OVERHEAD TO UNDERGROUND CONVERSION ISSUED: 12/14/2021 Address: 19726 88TH AVE W EDMONDS WA 98026-6307 EXPIRES: 06/14/2022 rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00549300000400 i NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER JOHNSON LISA & CORY 19726 88TH AVE W, EDMONDS WA 98026 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 9 12/14/2021 RELEASED BY DATE Printed: Tuesday, December 14, 2021 12:46:27 PM 1 of 2 -KRWOF WAY EUC PERMIT City of Edmonds ...• •ENG2021-0425 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROL Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION MEN RESULT A-1 JOB START X-2 ENGINEERING FINAL" E-7 TRAFFIC CTRL Printed: Tuesday, December 14, 2021 12:46:27 PM 2 of 2 6 \ -ENG2021-0425 RIGHT OF WADY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal 4ic, �1590� Requirements outlined in Right -of -Way permit Handout E6.1 If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Appl*W ,4gnied. SONONO3 =10 A-LIO � ZOZ ZO AON SECTION A a A A I A O A M Name of Company u c) Franchise ordinance No: Point of Contact Title Address City 1 1) ere State zip "�L%G Name of Company - Primary Name . Agent Name Title Title Mobile Address Email City State Zip Secondary Name Phone Title Email Mobile City of Edmonds Business License No: Email State License No: 3t"!:. — on � s `9 l Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance ..y.— y uwLuru w,eu-ucwr- u,"esa uucerunse approvea oy me ctrg engineer. Type of Development — Check ALL that apply ❑ Multifamily residential ❑ Commercial ❑ City project * Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welD Traffic Control Only (no associated development) :j Utility Franchise Work (no associated development) ity of Edmonds ROW construction permitAppEcation--Page i of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) v� � • a ��. n:.rr.v� � v� Gr . RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x IF SF Alley 72 hours + IF x LF SF Parldng 72 hours + IF x LF SF SECTION B - If you are not a utility company performing work in the City ROW,•skip to SECTIONC. Ge of- ��Facilitfes i. The work in the right of way is on or for the following type of facilities:: ❑ telecommunications ❑ cable Xpower ❑ gas ❑ water ❑ sewer ❑ storm Details of Work o be Completed �. Does the utility owner have existing overhead infrastructure in the area of work? Yes No 2. Will an ui ment be added underground or above ound (e.g. pedes_als, vaults, etc.)? If yes, describe: `Tv, 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? ✓� 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? 5. Does the work involve proposed additions to an aboveground utility stem? If es: Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Does your project involve rebuilding or replacing utility equipment which currently serves more 6. than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: How many are exist in ? How many are to be added? City of Edmonds ROW construction permitApplication--Page 2 of 3 Updated 3/25/2o21 Qn � 6b. Does your project involve poles? If yes: How many poles are existing in the pxo'ect area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? What is the height of the additional oles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: How many? What is the height of the poles.after? Describe the modification rebuild: Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-3o5 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to' any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall complywith them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: APPLICANT PRINTED NAME: APPLICANT TITLE: NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE man City of Edmonds ROW construction permitApplication—Page 3 of 3 Updated 3/25/2021 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM POLE 9522 o -RMV EXISTING #2 OH TPX FROM o TO -HANG 37 KVA OH XFMR (12F601) UTC # SER # -RUN 50' OF OH 1/0 FROM © TO POLE 221980 C -RMV EXISTING #2 OH TPX FROM ©TO 19726 -INSTL 3" SEC RISER -SET SML PED AT BASE OF PLI 221980 (AS STAKED) -RUN 350 KCMIL WIRE FROM PED TO RISER AND CONNECT TO NEW 1/0 OH WIRE Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED tlQ�VV,_&J,1 4z 12/13/2021 RESUB DEC 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2 O 9523 19801 3 3 50-3237 L- _ ,1/12 -1 63-A � z 19726, o M 19805 P ----- 9522 221980 © SL-125248-A 730 --- 19811 a moo O LOCATION 19726 88th Ave W, Edmonds, WA 98026 AREA LYNNWOOD POLE NO PLI 9523 VaS 19 T 27 R 4 DATE 12/1/21 ORDER 100085777 REASON FOR WORK INSTL RISER RED FOR OH ENGINEER WANG OPERATION 60 TO UG CONVERSION DRAFTER UGND NO 50 KW CONNECTED LOAD APPROVED SCALE DATE PRINTED DATE WORK COMPLETED FOREMAN SUBSTATION MPL FEES REO'D CIRCUIT NO 12-346 PHASE 123 ❑YES ONO PRIMARY OVERHEAD ENGINEER G. WANG ❑ RESIDENTIAL PHONE 425-670-3205 ❑ COMMERCIAL LEOµ CELLULAR 425-231-0984 a s = s PRIMARY UNDERGROUND NESC VIOLATIONS ❑ RESIDENTIAL ❑ NO ❑ YES (SEE NOTES) ❑ COMMERCIAL PERMITS (DATE GRANTED) BASIC FEE 3 ❑ TREE TRIM LEUµ ❑ STATE gam = $ ❑ COUNTY SECONDARY UNDERGROUND ❑CITY BASIC FEE% ❑ Q gam,_ % EASEMENTS ❑ REQUIRED UNDERGROUND PLAT E» ❑ NOT REQUIRED BASIC FEE$ ENGINEERING DATE SENT TO R/W 6- FT Q $ = i DATE APPROVED PLAT CONSTRUCTION FOREIGN CONTACTS G FT e 3 = % ❑ JPN# STREET LIGHTING ❑ JOINT TRENCH ZIPLY & CATV C FT m 3 = 3 ❑ JOINT BORE ZIPLY & CATV CROSSINGS ❑ t FT =3 WORK IN RIGHT OF WAY POLE STENCILING ❑ PRIMARY FROM TO ❑ SECONADARY TAKE OFF POLE IL FT ® 3 = s PRE-CONSTR REQUIREMENTS MISCELLANEOUS FEES ❑ TREE TRIM ❑ PUD LOCATOR VAULT f ❑ BACKHOE ❑ PERMIT f ❑ ONE CALL DATE $ No. s STREET LIGHTWG $ ❑ YES ❑ NO g M&R AS -BUILT TOTAL DUEf GIS N NORTH DI AKI \/TC\A/ DATE PAID RECEIPT* GIB Ph NEW SVCE APPLICATION- LOCATION MAP VICINITY MAP I F7(_F__NIfl- 0 EXISTING POLE EXISTING POLE -TO BE REMOVED NEW POLE )� NEW POLE TO REPLACE EXISTING POLE EXISTING DISTRIBUTION LINE — — — — — — NEW DISTRIBUTION LINE — EXISTING TRANSMISSION LINE NEW TRANSMISSION LINE ------------ NEW SECONDARY CONDUCTOR RIGHT-OF-WAY LINE PROPERTY LINE 3E LINE TO BE REMOVED LANE CLOSURE ON A TWO-LANE ROAD (TWO FLAGGER OPERATION) ROAD W20-1 WORK AHEAD x ONE LANE W20-4 ROAD AHEAD x W20-7A x zx 00 00 N V� x END G20-2 ROAD WORK 48'' x 24'' (OPTIONAL) w i W Q Z H- 00 00 48'' x 24'' i END G20-2 ROAD WORK x (OPTIONAL) 0 0 PLI 9522 Of .. N NORTH I SIGN SPACING = X FREEWAYS & EXPRESSWAYS 55-70 MPH 1500'+ RURAL HIGHWAYS 60-65 MPH 800'+ RURAL ROADS 45-55 MPH 500'+ RURAL ROADS & URBAN ARTERIALS 35-40 MPH 350'+ RURAL ROADS & URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25-30 MPH 200'+ (2) URBAN STREETS 25 MPH OR LESS 100'+ (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT —GRADE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. zx w 00 Ln0 7 x ❑v s W20-7A x ONE LANE s ROAD W20-4 AHEAD x ROAD i WORK W20-1 AHEAD SPEED LIMIT ON 88TH AVE W IS 25 MPH ENGINEERING DIVISION APPROVED AS NOTED lll/ AQ.x 12/13/2021 vv W20-7B BE PREPARED TO STOP OPTIONAL IF 40 MPH OR LESS RESUB DEC 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT THIS PLAN MAY BE MIRRORED FOR OPPOSITE SIDE OF ROADWAY USING SAME SIGNS AND SPACING. YES ❑ NO ❑ INITIAL GENERAL NOTES: 1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD. 2. NOTIFY LOCAL EMERGENCY SERVICES OF CLOSURE TIMES AND DATES (OPTIONAL). 3. SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROAD CONDITIONS. 4. PROTECTIVE VEHICLE RECOMMENDED —MAY BE A WORK TRUCK. 5. ALL SIGNS MINIMUM 48'' X 48'',UNLESS OTHERWISE SPECIFIED. 6. CHANNELIZATION DEVICES ARE 28'' REFLECTIVE CONES. SEE TABLE 1 FOR SPACING DISTANCES. 7. ALL SPACING MAY BE ADJUSTED TO ACCOMODATE AT —GRADE INTERSECTIONS AND/OR DRIVEWAYS. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (FEET) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 LBS. HOST VEHICLE WEIGHT > 22,000 LBS. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 1 150' v_vnm CHANNELIZATION DEVICE SPACING (FEET) MPH TAPER TANGENT 50-65 10 TO 20 80 35-45 10 TO 20 60 25-30 10 TO 20 40 • CHANNELIZING DEVICE r FLAGGING STATION PORTABLE SIGN AND SUPPORT �® WORK VEHICLE WITH FLASHING LIGHT WORK AREA RESUB Date: 12/1/21 DEC 01 2021 Project: 19726 881h Ave W, Edmonds, WA 98026 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. The plans have been updated to reflect the correct location of the aerial drop. 2. The existing service has a wire (#2 AAC TPX) that cannot handle the increase of load for the new electrical service at 19726 88th Ave W. It must be removed and replaced with a larger wire (1/0 AWG AAC) that can handle the new load. 3. The transformer has been added to the drawing (It is represented with a Triangle A) on pole (B). 4. A traffic control plan has been added showing the one lane closure with two flaggers. The walkway is to remain open as instructed. Please reach out immediately to me if there are any further questions. Garrett Wang Assistant Designer - Lynnwood Office (425) 670-3205 Office (425) 231-0984 Cell giwang@snopud.com PU "