Loading...
BLD2021-1704_Manufacturer_Specifications_and_Installation_Instructions_12.15.2021_6.25.20_PM_2575974R innai. ■ FLEXIBLE VENTING OPTIONS • Concentric or Schedule 40 PVC/CPVC • Direct Vent (Concentric and Twin Pipe) • Non -Direct Vent (Room Air) • Common Vent (Direct Vent and Room Air) Vent lengths up to 150 ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths: Twin Pipe Vent Sizes 2 in. (51 mm) 3 in. (76 mm) Vent Lengths 65 ft (20 m) 150 ft (46 m) Concentric Vent Sizes 2 in. X 4 in. 3 in. X 5 in. Vent Lengths 65 ft (20 m) 150 ft (46 m) ■ EASE OF INSTALLATION AND SERVICEABILITY • Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Sliding Mounting Bracket for Easy Installation • Simple Gas Conversion ■ OPTIONAL ACCESSORIES Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Recirculation Pump, DPS/MIS Switch, EZConnectT" Cables, Cascade Cables, control•rT" Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories. COMMERCIAL SUPER -HIGH -EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type Internal (Indoor) Commercial Applications Model Numbers CU199i (REU-N3237FFC-US) CU160i(REU-N2530FFC-US) Approved Gas Types Natural and Propane UEF up to 0.93 Thermal Efficiency: Up Efficiency Ratings not certified to 97% by AHRI EF: 0.96 (CU199i) 0.95 (CU160i) High Altitude Approved Up to 10,200 ft (3,109 m) Water Flow Control Water Flow Sensor, Electronic Water Control and Bypass Control Controller Standard: Integrated Controller Optional: MC-91-2US Certifications AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR® Warranty • Heat Exchanger: 8 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2), and Self -Tapping Screws (x2) Additional Features • Complies with South • Ultra Low NOx Coast Air Quality e Tankless Rack System— Compatible Management District • 1 2 in. 13 mm Gas Line Compatible 14 ng/J or 20 ppm / ( ) p NOx Emission Levels COMMERCIAL APPLICATIONS Commercial Tankless Rack Systems Demand Duolm Commercial Hybrid System CIPSA°CUS IRRIMM MT., LOW Eno SANITATION " CONTENT CERTIFIED TO ANSI Z21.10.3 - CSA 4.3 RINNALUS . 1-800-621-9419 ITm TECHNICAL SPECIFICATIONSSENSE SPECIFICATION CU199i CU160i Dimensions - w, h, d 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) Minimum Gas 15,000 Consumption Btu/h Maximum Gas Consumption Btu/h 199,000 160,000 Flow Rate' 0.26 - 9.8 GPM 0.26 - 8.0 GPM (Min - Max) (1.0- 37 L/min) (1.0- 30 L/min) Max Flow Rate with 11 GPM 9 GPM Parameter Adjustment (42 L/min) (34 L/min) Weight 64 Ib (29 kg) 62 lb (28 kg) Sound Level 49 dB 48 dB Normal 84 W 52 W Standby 1.3 W Freeze Protection 148 W ai �u Max Current 4 Amps Fuse 10 Amps • Minimum: 98' F (37' C) Default Temperature • Maximum: 140° F (60` C) Default 185' F (85' C) With Parameter Adjustment By -Pass Flow Control Electronic Gas Supply Pressure • Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c. Ignition System Direct Electronic Ignition Electronic Connections • Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital) Water Supply Pressure • Minimum: 50 PSI (Recommended 60-80 PSI for max performance) • Maximum: 150 PSI Controller Cable Non -Polarized Two Core Cable (Minimum 22 AWG) • Gas Supply: 3/4 in. (19 mm) NPT Service Connections • Cold Water Inlet: 3/4 in. (19 mm) NPT • Hot Water Outlet: 3/4 in. (19 mm) NPT • Condensate Drain: 1/2 in. (13 mm) NPT • Top: 2 in. (51 mm)* • Back: 0 in. Clearances • Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** • Front: 0 in.** • Vent: 0 in. * 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). Z The maximum gas supply pressure must not exceed the value specified by the manufacturer. Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21' C), please contact Rinnai. 12 Fl,..., 9 8 f 7 a S6 05 LL v4 3 3 2 1 0 in. (mm)I FRONT 5.90 (150) o� v �M co Co o 0, N r, M n 18.5 (47070) SIDE 6.08 (154)4 Vent Connection: 2 in. (51 mm) nominal PVC/ Polypropylene or 3 in./5 in. Concentric. 'oZZ, od N N �1 1.45 (290) 18.5 (47070) SIDE 6.08 (154)4 Vent Connection: 2 in. (51 mm) nominal PVC/ Polypropylene or 3 in./5 in. Concentric. 'oZZ, od N N �1 1.45 (290) A 7.60 193 0 25 50 75 100 125 150 Delta T - Temperature Rise (°F) I I