ENG2021-0373 ROW PERMIT ODOR SCRUBBER FOR WWTPOF WAY PERMIT
PERMIT NUMBER
City of Edmonds
AveRIGHT
9801 1 C
www.cityofedmonds.gov
Description: ROW IMPROVEMENTS ASSOCIATED W/ ENG2021-0228 (ODOR SCRUBBER)
ISSUED: 12/17/2021
Address: 600 3RD AVE S EDMONDS WA 98020
EXPIRES: 06/17/2022
Permit Type: RIGHT OF WAY Permit Subtype: CITY Parcel Number: 27032600101300
NAME TYPE NAME ADDRESS PHONE
APPLICANT MICHAEL DERRICK, CITY OF 200 2ND AVE S, EDMONDS WA 98020 (425)218-1155
EDMONDS
CONTRACTOR GENERAL MECHANICAL, INC. 2316 S. STATE ST, TACOMA WA 98405-2813 (253)606-5983
OWNER EDMONDS CITY OF 250 5TH AVENUE N, EDMONDS WA 98020
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00
ENGINEERING INSPECTION FEE $110.00 $110.00
RIGHT OF WAY STANDARD PERMIT FEE $330.00 $330.00
•
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
77 INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments
or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of
granting this permit.
THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW
ENGINEERING DIVISION
APPROVED AS NOTED
RELEASED BY %T,rta�re �12/17/2021 DATE
Printed: Friday, December 17, 2021 10:33:27 AM 1 of 2
KIRRMF WAY PERMIT
PERMIT NUMBER
City of • • •
•:• •ENG2021-0373
www.cityofedmonds.gov• •
CONDITIONS
CONDITION TYPE
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
ESC REQ
Maintain erosion and sedimentation control per City and SWMMW standard requirements.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
Sound/Noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on
SOUND OR NOISE
weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites/activities must comply with the noise limits
of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
TRAFFIC CONTROL
Traffic Control per approved plan and MUTCD. All Flaggers shall be certified.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE
DATE
RESULT
COMPLETE
A-1 TESC AND MOBILIZE
X-2 ENGINEERING FINAL"
E-7 TRAFFIC CTRL
Printed: Friday, December 17, 2021 10:33:27 AM 2 of 2
pF ED,tlo
INC. 13ao
SECTION A
ENG2021-0373
RESUB
RIGHT OF WAY CONSTRUCTION
PERMIT APPLICATION DEC 08 2021
Complete and submit this Application in accordance with the Submittal CITY OF EDMONDS
Requirements outlined in Right -of -Way permit Handout E63. DEVELOPMENT
SERVICES DEPARTMENT
If any field is not applicable to your project, Write "N/A" instead of leaving blank.
All fields required. Incomplete Applications will be denied.
General •
Project Name C,;Ay C Q Fe)'O")s ciy-x pq►-iC 0doy Ce'tf" (
Site Address or if no site address use Property Address at NW corner of project area: Z md A Ve— S
Associated Permits: BLD PLN ENG
Owner and Entity Holding
Name of Company c i o-
Franchise
O -Q
(if applicable) Z
F'1J .."O'c3 s Franchise Ordinance No:
Point of Contact,A1«h
r,v--.c-k
Title
P1-0J)-4#nwt
i ti;
►-4 fO t'
Address
B D -4heA
Ave.
5 .
City
State
zip q96 z o
Phone
412 S—(9 Irr
Email
A
ee rr' G 1<
CJ rM O 4�
V
Contractor and Authorized Agent of Owner (see note below)
Name of Company C r-Q i c at I Z iCG ,
Contractor Contacts During Construction
Primary Name k__ S
Agent Name
; ego"J
Title " Le Nero 19 e Y
Title me.,- .+
Mobile - 6o6-
Address Z-3((� S 3<p� Sf
Email (?G rtj i �lB m tp�t4
City r C
State w
Zip Q S
Secondary Name
Phone _ 6 - g 17'
Title
Email rn i0 n 4 0 '•4(0'ee_40t"c 4 i. COWL
Mobile
City of Edmonds Bu iness License N : -2S Q'.r QQ 7
`T
Email
State License No: E /A 'k � 1, F
XContractor verifies it is currently bonded
Contractor verifies it currently has general liability insurance
ivvl n: rc_,uu us.ou.uzu requires rnar me nppttcanon oe signed oy a licensed ana bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial o ity project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
❑ Utility Franchise Work associated with development (check one of the above boxes as well)
❑ Traffic Control Only (no associated development)
❑ Utility Franchise Work (no associated development)
City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021
! k
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
CX LF
x
LV LF
1144 SF
/U
Alley2 hours +
LF
x
/Y LF
1414 SF
Parking 72 hours +
&- LF
x
/Y/4 LF
IV4 SF
1,4
SECTION B - If you are not a utility company performing work in the City ROW, skip to SEC77ON
1. The work in the right of way is on or for the following type of facilities::
❑ telecommunications ❑ cable "ower n gas
❑ water jR-sewer ❑ storm
Details of Work to.Yes
I. Does the utility owner have existing overhead infrastructure in the area of work?
No
2. Will any equipment be added underground or above ground e.. pedestals, vaults etc.)?
If yes, describe:
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility stem?
k
Does the work involve proposed additions to an aboveground utility stem? If es:
Are the additions for the purpose of serving new commercial development?
Are the additions for the purpose of serving a single-family residential subdivision?
�c
Details
of Work. be Completed
,
6.
Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
y
If yes, answer the following questions related to project area, i.e. the actual area in which the
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
How many are existing? How many are to be added?'
-
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
6b.
IDoes your project involve poles? If yes:
How many poles are existing in the project area?
AU11
-:i_' ,
What is the height of the existing poles?
am
How many poles are to be removed?
W1
Are additional Doles to be laced?
WM
How many? I I What is the hei t of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
�(
How many? What is the height of the poles after?
low
Describe the modification rebuild:
R
sT`T
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE:
APPLICANT PRINTED NAME:
APPLICANT TITLE:
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
TRAFFIC
MANAGEMENT
I N C O R P O R A T E D
RACEWAY UTILITIES
GENERAL NOTES -TRAFFIC CONTROL
It is the responsibility of the contractor performing work to install and maintain the traffic control devices as shown herein, as well as any such additional
traffic control devices as may be required to ensure the safe movement of vehicular and pedestrian traffic through or around the closure area and provide
maximum protection and safety to workers.
All traffic control devices shall be kept in their proper position at all times and shall be repaired, replaced, or cleaned as necessary to preserve their
appearance, continuity and capability.
All traffic control devices shall conform to the latest accepted edition of the Manual on Uniform Traffic Control Devices ( M.U.T.C.D.).
Any revisions to these drawings shall be approved in writing by the Engineer of Record and the Agency having jurisdiction.
The Agency Traffic Engineering Division reserves the right to observe the traffic control operations and to make any necessary changes. Any directed
changes shall supersede these plans and shall be implemented at the sole expense of the contractor.
Contractor shall provide flagmen as necessary to give adequate warning to traffic or to the public of any dangerous conditions to be encountered.
Contractor shall remove temporary traffic delineation, signage, and other devices when no longer required, and shall restore areas to original conditions.
Contractor shall cover existing signs where they conflict with construction detours and signing.
All open excavation or construction work shall be a minimum of 5' from any operating traffic lanes.
Contractor shall post uneven pavement signs, and ramp vertical pavement offset of 1 inch or more with asphalt for smooth transition.
The contractor shall provide for access to all adjacent properties during work hours. Construction operations shall be conducted in such a manner as to
cause as little inconvenience as possible to abutting property owners/operators.
All signs shall be reflectorized and standard size.
The contractor shall provide for safe pedestrian access at all times.
SIGN SPACING = X (1)
MINIMUM LANE CLOSURE TAPER LENGTH = L (FEET)
LANE POSTED SPEED LIMIT (MPH)
WIDTH
(feet) 25 30 35 40 45 50 55 60 65 70
10 105 150 205 270 450 500 550 - - -
11 115 165 225 295 495 550 605 660 -
12 125 180 245 320 540 600 660 720 780 840
LEGEND
® - WORK AREA
FLAGGER
FLASHING ARROW 51GN (FA5)
P.o UNIFORMED POLICE OFFICER
d EXI5TING 51ON
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED
(MPH)
25
30
35
40
45
50
55
60
65L733O
LENGTH
(feet)
155
200
250
305
360
425
495
570
645
TANSPORTABLE ATTENUATOR ROLL
AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
HOST VEHICLE WEIGHT
9,900 TO 22,000 lbs.
> 22,000 lbs.
< 45
45-55
> 55
< 45
45-55
> 55
MPH
MPH
MPH
MPH
MPH
MPH
100'
123'
172'
74'
100'
150'
I TYPE -III BARRICADE W/ 51GN
X TYPE -II BARRICADE W/ SIGN
]I ADA BARRICADE W/ SIGN
• CHANNEUZATION DEVICE
51GN
FREEWAYS & 55/70 MPH
1500' +/-
EXPRESSWAYS
RURAL HIGHWAYS 60/65 MPH
800' +/-
RURAL ROADS 45/55 MPH
500' +/-
RURAL ROADS & URBAN 35/40 MPH
350' +/-
ARTERIALS
RURAL ROADS & URBAN
ARTERIALS 25/30 MPH
200' +/- (2)
RESIDENTIAL &
BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS
100' +/- (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE
RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO
FIT ROADWAY
CONDITIONS.
ADDRESS
FINE ST & 2ND AVE 5
EDMONDS, WA
MINIMUM SHOULDER TAPER LENGTH =
L/3 (FEET)
SHOULDER
WIDTH
(feet)
POSTED SPEED LIMIT (MPH)
25
30
35
40
45
50
55
60
65
70
8
40
40
60
90
120
130
150
160
170
190
10
40
60
90
90
150
170
190
200
220
240
WORK AREA TRAFFIC CONTROL: PINE ST & 2ND AVE 5
CONTACT: LEVI VENN
CONTACT: 253 569-0917
JOB NUMBER: 515064 PLAN#: 66300
PERMIT NUMBER:
COVER SHEET SIZE: B 5CALE: N.T.5.
DATE: 9/3/2021 PREPARED BY: EL
RESUB
DEC 08 2021
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
TRAFFIC MANAGEMENT, INC.
California - Great Lakes - Pacific Northwest
800.763.3999
www.trafficmanagement.com TMIIN
Traffic Control Services - Sales & Rentals
Permits & Consulting - Engineering - Training
C31 # 785804
TMI CONTACT PERSON: Valeriy Kotyay
TIES CERT #: 008319
F-50' - 100'-1
rI
I-
� � M
L100,1100 111001i
NT5 NT5 NT5
W20-1 W20-7a
ROAD W20-4
WORK
AHEAD ONELANE
ROAD
AHEAD
LEGEND
®
WORK AREA
I
-TYPE-III BARRICADE W/ SIGN
r
FLAGGER
X
TYPE -II PARRICADE W/ SIGN
FLASHING ARROW SIGN (FA5)
]I
ADA BARRICADE W/ SIGN
�E>
UNIFORMED POLICE OFFICER
•
CHANNELIZATION DEVICE
d
EXISTING SIGN
I
SIGN
FLAGGER WITH
RADIO COMMUNICATION
FLAGGED TO A5515T
PEDE5TDIAN TRAFFIC ■
ADDRES5
FINE 5T & 2ND AVE 5
EDMONDS, WA
12'
W20-7a
(— f 0 0
100'
NT5
1� W3-4
100'
NT5 BE
PREPARED
TO STOP
100' W20-1
NT5
ROAD
WORK
AHEAD
0' 20' 40' 80'
SCALE: 1 " = 40'
W20-4
W20-7a
ONE LANE W20 1
ROAD
AHEAD ROAD
WORK
AHEAD
�— 50' - 100' 100' 100' 100'
�NT5—rNT5—r—NT5jr
FINE ST [ 25 MPH ]
ENGINEERING DIVISION
APPROVED AS NOTED
2/ 14/2021
FLAGGER WITH
RADIO COMMUNICATION
CHANNELIZATION
DEVICE SPACING (feet)
MPH
TAPER
TANGENT
50/65
10 to 20
80
35/45
10 to 20
60
25/30
10 to 20
40
WORK AREA TRAFFIC CONTROL: FINE 5T & 2ND AVE 5
CONTACT: LEVI VENN
CONTACT: 253 569-0917
JOP NUM1 EK: 315064 FLAN#: 66500
FEKMIT NUMPEK:
5HEET 1 OF 1 SIZE: P SCALE: 1''=40'
DATE: 9/3/2021 FREFAKED BY: EL
RESUB
DEC 08 2021
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
TRAFFIC MANAGEMENT, INC.
California • 6reat Lakes • Pacific Northwest
800.763.3999
www.trafficmanagement.com TMIIN
Traffic Control Services - Sales & Rentals
Permits & Consulting - Engineering - Training
C31 # 785804