Energy CalculationsWindow, Skylight and Door Schedule Project Information Birkby Residence Addition Remodel 839 Cary Road Edmonds, WA 98020 Ref. U-factor Exempt Swinging Door (24 sq. ft. max.) Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component Description Ref. U-factor All Windows 0.30 Contact Information Daniel G. Weller, Inc. 1621 Central Avenue S, Suite A Kent, WA 98032 Width Height Qt. Feet inch Feet inch Width Height Qt. Feet Inch Feet Inch M®E®E --E-E --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ F-11 1S �L`1 11 111 11 111 Area UA 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Overhead Glazing (Skylights) Component Description Ref. U-factor Width Height Qt. Feet Inc" Feet Ire" Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 747.1 224.13 0.30 Area UA 11 111 11 111 11 111 11 111 11 111 11 111 11 111 1 11 747.1 224.13 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Birkby Residence Addition Remodel 339 Cary Road Edmonds, WA 98020 Heatinq System Type: ® All Other Systems Contact Information Daniel G. Weller, Inc. 1621 Central Avenue S, Suite A Kent, WA 98032 o Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Design Temperature Difference (AT) Edmonds1W AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazinq and Doors Instructions Skylights Instructions Insulation Attic Instructions �fR 49 Single Rafter or Joist Vaulted Ceilings Instructions R-38 Vented Above Grade Walls (see Figure 1) Instructions 1 6R-21 Intermediate Ji Floors It Instructions Ft 30 Below Grade Walls (see Figure 1) Instructions Select R-value Slab Below Grade (see Figure 1) Instructions JJ[S�el.,tnditioning � Slab on Grade (see Figure 1) Instructions 1 Select R-Value Ji Location of Ducts Instructions a Unconditioned Space J Figure 1. Above Grade Below Grade 4,841 Conditioned Volume 8.01 38,728 U-Factor X Area = UA 0.30 747 224.10 U-Factor X Area = UA 0.50 --- U-Factor X Area = UA 0.026 3,493 90.82 U-Factor X Area UA 0.027 186 5.02 U-Factor X Area UA 0.056 2,749 153.94 U-Factor X Area UA 0.029 3,679 106.69 U-Factor X Area No selection F-Factor X Length No selection F-Factor X Length No selection Sum of UA Duct Leakage Coefficient 1.10 Envelope Heat Load Sum of UA X AT Air Leakage Heat Load Volume X 0.6 X AT X .018 Building Design Heat Load Air Leakage + Envelope Heat Loss UA UA UA 26,706 Btu / Hour 19,240 Btu / Hour 45,947 Btu / Hour Building and Duct Heat Load 50,541 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 70,758 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information Birkby Residence Addition Remodel Daniel G Weller, Inc. 839 Cary Road 1621 Central Avenue S, Suite A Edmonds, WA 98020 Kent, WA 98032 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb,e n/a n/a Ceilingk 4Y 0.026 Wood Frame Wall,,m,n 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 301 0.029 Below Grade Wall" 10/15/21 int + TB 0.042 Slab R-Value & Depth 10, 2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Date Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. ❑ 2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑ 3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 1 b Efficient Building Envelope 1 b 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions 0.5 *1200 kwh 0.0 0.50 Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. " Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. Reserved. k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3.