APPROVED BLD PLN_BLD2020-1418+Architectural_Plan+12.30.2020_4.21.27_PM+1968478N �—
APPROVED BY PLANNING
C.i� t
��
Jan 26 2021
I
• Special:inspection is required for I
I Structural Epoxy •
I
I�����������������������������7
I Special inspection is required for welded
j structural elements. Fill out attached special j
• inspection form with'the name and contact '
j information of the WABO certified special j
inspector or welding shop that will be used on �
I this project.
■�����������������������������7
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
APPROVED BY
CITY OF EDMONDS
BUILDING DIVISION
Jan 20 2021
City
Of Edmonds
Building Department
Work
------------------------------
ADDIT109N/REMODEL
Address
224 SKYLINE DR
Owner
HERZIG
Approved Date
01 /20/2021
Building Official :�
w. � �iisuc
Permit Number � gLD2020-1418
RECEIVED
Dec 31 2020
CITY OF EDMONDS_.
DEVELOPMENT SERVICES
DEPARTMENT
�i
o
�W+
L.L
' N
O
�
�,
U
��
M
_..
Ll.l
N�
F-- W
� °'
��
o
Q
�N
� d„
U
W
�^W
1.1�
N V
��
�IU
��
Q cn
� -�
�a�-
,,
zz
W �
�3
E�
cry
W
I,1„l
o
0
T
U
C
N
c�
0
N
0
��o
..�
0
�'
o
w
0
Wo
�W
�
Q}
Y
N
N
Revisions
DOOR SCHEDULE
MARK
NOMINAL
SIZE
JAMB
STYLE
MATERIAL
HARDWARE
REMARKS
1
i 10-0 x 9-0
N/A
GARAGE
VERIFY W/
OWNERS
REMOTE &
KEYPAD
R DIU E ' T WI H "CAR IA "
FINISH. SEE SHT A3.1
2
10-0 x 9-0
_ _
-
10
25-0 x 8-0
N/A
MULTI SLIDE
ALUM CLAD
FIBERGLASS
KEYED
VIN' U 1- I KI'
POCKETING COMBO. SEE'PLANS & ELEVS
11
6-0 x 6-8
�,
SNDING
MATCH E
,,
12
2-4 x 6-8
4-9/16,
SWING
VERIFY W/
OWNERS
PRIVACY
13
2 2-0 x :6-$
„
DBL SWING
;DUMMY
14
` 3-0 x 6'-8
VVIF
SWING
"
PASSAGE
NOTES
1 CENTER ALL DOORS ON WALLS OR 6" FROM WALLS U.ON: ON PLANS (VERIFY'W/ OWNERS)
2 FULL LITE EXTERIOR .DOORS TO HAVE U = .28 OR .LESS
3 OPAQUE'EXTERiOR DOORS TO HAVE U = .20 OFF LESS
4 At_L U VALUES TO BE NFRC CERTIFIED
15 ALL GLAZING INDOORS AND SIDELITES ASSOGIA�"ED WITH DOORS TO BE SAFETY GLAZING
WINDOW SCHEDULE
u
MARK
NOMINAL�SIZE
STYLE.
MATERIAL
FACTOR
QUANT
REMARKS
.28 0R
A
4-0 x 5-0
FIXED
FIBERGLASS'
LESS
1
� B!
B
2-0 x 2-Ol _
CASEMENT
,�
,,
21
„
C
6-0 x 4-0
SLIDER
'�
��
1
,�
NaTEs:
_
1
SEE EXTERIOR'ELEVATIONS FOR OPERATION OF OPERABLE UNITS
2
U-VALUES TO BE NFRG CERTIFIED
3
PROVIDE: SAFETY GLAZING AT WINDOWS MARKEfl A AND AS REQ.
BY CODE
GENERAL NOTES
_t , .
1. PROVIDE SMOKE DETECTORS AT HALLWAY LEADING TO SLEEPING ROOMS
AND AS REQUIRED BY'CODE. SMOKE DETECTORS T B
O E HARD WIRED
AND INTERCONNE TE .SMOKED T
.; J
s
C D E ECTORS SHOWN ON PLANS AS.
' N a
2. PR VI
O DE ARB IDE D
C/ C ON MONOX ETECTORS WHERE SHOWN AS.
� �� h
s_ �
: ❑
.�t � � �-�
�_v r
,�x, �_ 3. VERIFY L A
OCATION AND U NTITY OF FIX
Q ED VERSUS OP -
e
ERABLE
WIN
DOWS
.. -'
WITH OWNER P RDERIN
RIOR T Ca G
,, O
h
/c
!o
v
c;
� � �
5
5
Q
1 4. PR `VI WH
O DE SAFETY GLAZING ERE MARK D
E AS AND
c AS RE U1 E
r� Q R D
�.w- �:
BY CODE.
� I
f � .
(, _
��-
`J .�- f' G
I
5.
"- ALL GLAZIN D
G IN D R N S DELIT
N � 00 SA ESA
f _ SSOCIATED WITH D ;
�" OORS TO BE
U� ; j�
SAFETY GLA IN
1-f) ' ��� 2 � � IT1 �
Z G
6. PROVIDE 50 CFM EXHAUST FAN AT HALF BATH 3.
EXHAUST FANS SHOWN ON PLAN AS
ENERGY NOTES
1. ENERGY CREDITS REQUIRED = 1.5 (ADDN BETWN 500 & 1500 SO FT.)
ENERGY CREDITS SELECTED:
' ia. EFFICIENT BUILDING ENVELOPE: Prescriptive compliance based on table
R402.1.1 with the following modifications: (0.5 CREDITS)
Vertical Fenestration U = 028, Floor R= 38 (Eor this project)
3a. HIGH .EFFICIENCY HVAC EQUIPMENT: Gas fired boiler with minimum AFUE of
-I- 92% located in garage below new addi#Ian. (1.O CREDITS)
2. NEW HEATED AREA TO BE ON A STAND ALONE, HYDRONICALLYNEATED
FLOOR SYSTEM.
VENTILATION NOTES
1. PROVIDE VENTILATION IN NEW ADDITION PER CODE, INTEGRATED WITH
THE EXISTING F:A.U., OR AS ASTAND-ALONE ATTIC VENTILATION
SYSTEM.
LIGHTING NOTES
1. A MINIMUM OF 75% OF PERMANENTLY INSTALLED LAMPS IN LIGHTING
FIXTURES SHALL BE HIGH EFFICIACY LAMPS.
DIMENSION NOTES
1. DIMENSIONS WITH +/-
ADJUST AS REQUIRED. NOTIFY OWNER AND ARCHITECT IF ANY
DIMENSION SHOWN AS +/- IS MORE THAN 2" DIFFERENT FROM NOTED.
2. DIMENSIONS WITH (E) =EXISTING DIMENSIONS TO'RENIAIN THE SAME.
GUARDRAIL NOTES
III 1. GUARDRAILS WHERE REQUIRED TO BE 36"HIGH `{MINIMUM) WITH LESS THAN'4" SPACING
BETWEEN INTERMEDIATE RAILS. MATCH (E) GUARDRA(LSTYLE.
GUARDRAIL ELEMENTS AND'SUPPORTING CONNECTIONS TO BE INSTALLED TO RESIST A
Izuu rvulvu vt�ivtaN i nH � tU LVAU Ai'PLIEU: AT THE TOP OF THE GUARD.
INFILL COMPONENTS TO BE DESIGNED TO'RESIST A 50 POUND LOADiAPPLIED OUER'A
L12" X 12" AREA.
NEW WALL AREAS SHOWN ARE THE
MINIMUM AMOUNT REQUtRED.
WALLS SHOWN AS>EXISTING TO
.REMAIN MAY :NEED. TO BE REMOVED;
DURING DEMOLITION. VERIFY"1'N F11~LD.
VERIFY PRIOR TO DEMOLITION IF
ANY ITEMS NOTED. FOR REMOVAL
ARE TO BE REUSED: IN THE PROJECT ''
RECEIVED
Dec 31 2020
-. � CITYAF EDMONDS .
DEVELOPMENT SERVICES
DEPARTMENT
W
o
N
O
Q T
U �
�M
W���
-�
�.-
_�
Q
�N
��
UW
W
�, �
N U
,�Q
U�
U
��
Q �
��
zz
W J
o�
��
-�
_ �
W
W
0
T
U
N
c�
0
N
O
O
�� o■
N��
0
���
W
0�
W o
C� W
J
Q�
Y
N
N
Revisions
�� - I
` Dfl NflT SCALE DIMENSIONS FROM
-, DRAWINGS. WRITTEN INFORMATION
SUPERCEDES GRAPHIC INFO. RECEIVE
` � Dec 31 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
p
m�i
Y� iG��-- -off- r��N
� �N �
�v��-o.�� i� ,��i GH c��
�fl�� ,,�,° s�o���—o M�r� c�
i
3��1, 3�
�� ���
RECEIVED
Dec 31 `2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
��
W
o
N
O
�
�'
I�'R
�.�
�
w_
o
�N .:
'a d'
U W
W
�
N U
Q
V
J V
��
�C_cn
_0
��
�
Z �
_�
� `�
��
W_ �
o
��
�
W
LU
o
0
T
U
C
N
N
c�
N
O
c�
o_
_—
�-
0
oc
W
a�
W
o
W
_o
Y
d�
N
N
�,
_�
_ _ _.
� c� �
:
~
t
,. _ _ _
_
a
�"
Date_
2� p�G z,� za
Revisions:
RECEIVED
Dec 31 2020
i
�s'
_ _ _ _ _
_ ,..... ... CITYOF EDMONOS. .._....
DEVELOPMENT SERVICES
�°`
DEPARTMENT
STRUCTURAL NOTES
O G
(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS)
CODE
ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,
SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. SPECIFICATIONS AND STANDARDS
WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION.
DESIGN LOADS
DEAD LOADS:
ROOF 15 PSF
FLOOR 15 PSF
DECK 18 PSF
LIVE LOADS:
ROOF (SNOW LOAD) 25 PSF
RESIDENTIAL 40 PSF
DECK 60 PSF
(LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10).
EARTHQUAKE LOADS:
EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-10 SECTION 12.8.
SITE CLASS (ASSUMED)
D
SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS)
1.273
ONE SECOND SPECTRAL RESPONSE ACCEL (SI)
0.498
SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS)
0.849
ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI)
0.400
RISK CATEGORY
II
SEISMIC IMPORTANCE FACTOR (IF)
1.0
SEISMIC DESIGN CATEGORY
D
BASIC SEISMIC FORCE -RESISTING -SYSTEM
WOOD SHEAR WALLS
RESPONSE MODIFICATION FACTOR, (R)
6.5
REDUNDANCY FACTOR (p)
1.0
SEISMIC RESPONSE COEFFICIENT (CS)
0.131
W =TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-10 SECTION 12.7.2.
BASE SHEAR (V), V = CSW = RD I W
WIND LOADS:
BASIC WIND SPEED (3 SECOND GUST) 110 MPH
EXPOSURE B
KZT 1.0
SEE PLANS FOR ADDITIONAL DESIGN LOADS.
STATEMENT OF SPECIAL INSPECTIONS
SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A
WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF
WORK IN ACCORDANCE WITH CHAPTER 1704.4 OF THE IBC.
STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED.
FREQUENCY AND DISTRIBUTION OF P.EPORTS -INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY
SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS
SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL.
SPECIAL INSPECTION
OPERATION
CONT
PERIODIC
REMARKS
SOILS
FOUNDATION BEARING CAPACITY VERIFICATION
X
CONCRETE
ADHESIVE ANCHORS
X
IF REO'D
NOTE:
ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL
INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE
ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL
RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF THE DESIGN TEAM.
FOUNDATIONS: SPREAD FOOTINGS
SOILS REPORT: REPORT NOT AVAILABLE AT TIME OF DESIGN
ALLOWABLE SOIL PRESSURE: 2000 PSF (ASSUMED; TO BE FIELD VERIFIED DURING CONSTRUCTION)
FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND
AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS
REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE
CONDITIONS AND MUST THEREFORE BE ESTABLISHED BYTHE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW
COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE.
IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR
MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE
THAN 10% FINES (PASSING THE #200 SIEVE).
FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE
THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM
TEST METHOD D1557-00.
BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE
DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER
ARCHITECTURAL SPECIFICATIONS.
EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BYTHE OWNER.
IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL
ENGINEER FOR POSSIBLE FOUNDATION REDESIGN.
CONCRETE
ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF
ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS
(ACI 301).
ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS
PER CUBIC FOOT.
CONCRETE STRENGTHS AT 28 DAYS (f'c) AND MIX CRITERIA SHALL BE AS FOLLOWS:
MAXIMUM
MIN CEMENT
TYPE OF CONSTRUCTION
f'c*
WATER/CEMENT
CONTENT PER CUBIC
MAXIMUM
SHRINKAGE STRAIN
RATIO
YARD
FOOTINGS
3000 PSI
0.55
5 1/2 SACK
N/A
THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS
SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING
ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE
AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND
SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318.
ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BEAIR-ENTRAINED IN ACCORDANCE
WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1.
*PROVIDE f'c SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH
REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED.
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy
= 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED
SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL
PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE
SUBMITTED.
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP
WELDED WIRE FABRIC 12" AT SIDES AND ENDS.
REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP-66 AND ACI
318R, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS
SHALL BE PER SCHEDULE.
MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO
APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING
EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN
HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL
ENGINEER. REFER TO CHAPTER 7 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS.
MINIMUM LAPS AND EMBEDMENT
UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED
BELOW:
f'c = 3000 PSI
DEVELOPMENT LENGTH
LAP SPLICE
BAR
TENSION
COMPRESSION
TENSION
COMPRESSION
SIZE
TOP BARS
gARS
ALL BARS
TOP BARS
gARS
ALL BARS
#3
22
17
9
28
22
12
#4
29
22
11
37
29
15
#5
36
28
14
47
36
19
#6
43
33
17
56
43
23
#7
63
48
20
81
63
27
#8
72
55
22
93
72
30
NOTE:
1. ALL LENGTHS ARE IN INCHES.
2. ALL LAP SPLICES ARE CLASS B.
3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF
CONCRETE IS CAST IN THE MEMBER BELOW THE BAR.
CONCRETE GENERAL NOTES
VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE
NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A
HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS.
PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER
TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP.
ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO
POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED
BEYOND JOINT.
SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF
OPENINGS IN CONCRETE WALLS, FLOORS AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND
OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH
CORNER. EXTEND BARS 2'-0" BEYOND EDGE OF OPENING. IF 2'-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE
AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS.
BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR
APPROVED BYTHE STRUCTURAL ENGINEER.
SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND
OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS
NOTED.
LUMBER
ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA
GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS:
SIZE CLASSIFICATION
SPECIES
GRADE
Fb (PSI)
Fc (PSI)
SLEEPERS
DOUG-FIR
STUD
700
-
LIGHT FRAMING (STUDS)
HEM -FIR
STUD
675
800
2x JOISTS AND PLANKS
HEM -FIR
#2
850
-
PLATES AND BLOCKING
HEM -FIR
#2
850
-
6x AND LARGER BEAMS AND
STRINGERS
DOUG-FIR
#2
875
-
4x AND SMALLER BEAMS AND
STRINGERS
HEM -FIR
#2
850
-
ALL POSTS AND TIMBERS
DOUG-FIR
#1
1200
1000
REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS.
UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN
CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY
VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1.
NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD
ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BYTHE NATIONAL DESIGN STANDARDS (NDS) FOR
WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING
SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL
MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES:
NAIL
SHANK �
MIN LENGTH
8d COMMON
0.131f�
2 1/2" SHANK
10d COMMON
0.148Q1
3" SHANK
12d COMMON
0.1480
3 1/4" SHANK
16d COMMON
0.1620
3 1/2" SHANK
10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING
MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148"� x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED
WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS
ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION.
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS
OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE
SHANK AND THREADED PORTIONS PER NDS 11.1.3.
CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG
TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED
BYTHE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS,
SCREWS, OR BOLTS IN EACH MEMBER.
INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE
(MINIMUM) AS MEMBERS CONNECTED.
RATED SHEATHING
RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE
IN CONFORMANCE WITH IBC STANDARD 2303.1.4.
TIMBERSTRAND, MICROLLAM, AND PARALLAM MEMBERS
FABRICATED IN CONFORMANCE WITH THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORT
NO. ESR-1387 OR CCMC REPORT NO. 12627-R, 08675-R, AND 11161-R. EACH MEMBER SHALL BE IDENTIFIED BY A
STAMP INDICATING THE PRODUCT TYPE AND GRADE, ICC-ES OR CCMC REPORT NUMBER, MANUFACTURER'S NAME,
PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. FABRICATOR SHALL BE CERTIFIED. MEMBERS
SHALL MEET THE FOLLOWING MINIMUM STANDARDS:
SIZE CLASSIFICATION
SPECIES
GRADE
Fb (PSI)
Fv (PSI
Fc (PSI)
BEAMS &POSTS (d < 9 1/2")
LSL
1.3E
1,700
425
1,835
RIMS &BEAMS (d >_ 9 1/2")
LSL
1.55E
2,325
310
-
BEAMS &POSTS
LVL
2.0E
2,600
285
2,510
POSTS (d < 9 1/2")
PSL
1.8E
2,400
190
2,500
BEAMS (d >_ 9 1/2")
PSL
2.0E
2,900
290
-
TIMBERSTRAND, MICROLLAM, AND UNTREATED PARALLAM MEMBERS ARE INTENDED FOR DRY -USE APPLICATIONS.
UNLESS NOTED OTHERWISE, ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER
MANUFACTURES RECOMMENDATIONS.
GLUE -LAMINATED TIMBER
GLUE -LAMINATED TIMBER SHALL BE DOUGLAS FIR, FABRICATED IN CONFORMANCE WITH ANSI/AITC STANDARD
A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARI<AND SHALL BE ACCOMPANIED
BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE
FOLLOWING MINIMUM STANDARDS:
SPAN
COMBINATION
Fb
SIMPLE SPAN BEAMS
24F-V4
2400 PSI
CANTILEVER OR MULTI -SPAN BEAMS
24F-V8
2400 PSI
TYPICAL FRAMING NOTES
1. BEARING WALL FRAMING
2x STUDS @ 16" OC FOR ALL SHEAR AND/OR BEARING WALLS UNO.
REFER TO FRAMING PLAN NOTES FOR TYPICAL DOOR &WINDOW HEADERS NOT CALLED OUT ON THE PLANS.
HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD UNO.
COLUMNS BELOW FLUSH MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT
CALLED OUT OTHERWISE SHALL BE TWO STUDS.
WALL PLATES BEARING ON CONCRETE SHALL BE PRESSURE -TREATED. FOR ALL EXTERIOR AND INTERIOR WALLS,
BOLT PLATES OR SILLS TO CONCRETE STEM WALLS OR THICKENED SLAB FOOTINGS WITH 5/8 INCH DIAMETER
ANCHOR BOLTS WITH 7 INCH MINIMUM EMBEDMENT. PLACE AT 5'-0" OC MAXIMUM FOR SHEAR WALLS, AND AT
6'-0" OC FOR BEARING WALLS AND OTHER PARTITIONS. USE MINIMUM OF TWO ANCHOR BOLTS PER SILL AND
PLACE ONE WITHIN 12 INCHES OF END OF PLATES, TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. REFER TO
SHEAR WALL SCHEDULE. AT ALL SILL PLATE ANCHOR BOLTS, CONTRACTOR SHALL INSTALL 1/4" x 3" x 3" FLAT PLATE
WASHERS. INTERIOR NON-STRUCTURAL WALLS MAY BE ANCHORED TO CONCRETE SLAB -ON -GRADE WITH 1/4" x 3"
POWDER ACTUATED FASTENERS WITH 3/4" WASHERS AT 16" OC AND WITHIN 6" OF END OF PLATES.
(cam:ZiI�l�e\►1�l��iI�li�:Jle1► 11►[e]
PROVIDE 1 1/2" FULL DEPTH BLOCKING FOR JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8'-0" OC MAXIMUM
UNO. INTERMEDIATE 8'-0" OC BLOCKING NOT REQ'D IF GWB CEILING IS INSTALLED DIRECTLY TO UNDERSIDE OF
FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN.
PROVIDE TRUSS BLOCKING PANELS FOR ROOF TRUSSES AT SUPPORTS AND SHEAR WALLS, AND WHERE INDICATED
ON PLANS AND DETAILS.
ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE
PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING
FRAMING WITH 8d NAILS AT 6" OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS.
THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH
FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE.
5. ALLOWABLE STUD AND PLATE PENETRATIONS
CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN
EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING
PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN
NONBEARING PARTITIONS OR IF STUD IS DOUBLED. MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE.
6. GYPSUM WALLBOARD NAILING
ALL GYPSUM WALLBOARD SHALL BE NAILED TO ALL STUDS AND TOP AND BOTTOM PLATES WITH 6d COOLER NAILS
OR NO. 13 GAUGE x 1 5/8" @ 7" OC (5d COOLER NAILS FOR 1/2 INCH GYPSUM SHEATHING). TYPICAL UNLESS NOTED
OTHERWISE. INSTALLATION OF GWB SHALL BE SUCH THAT JOINTS ARE STAGGERED ON EACH SIDE OF A SINGLE
WALL.
EXISTING BUILDING
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING
DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE
REDESIGN.
CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS
PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH.
GENERAL
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND
MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT BEFORE PROCEEDING.
CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION
OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL
PERMANENT SUPPORT AND STIFFENING ARE INSTALLED.
CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL
ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS
ONLY WILL NOT SATISFY THIS REQUIREMENT.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT
SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL
ENGINEER.
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
12/ 30/ 2T0
J
Q
F-
H
Z
O m
� �
0_ N
� ~
C)
(n �
w w
� a
O
W �
Q O
� �
N
r-I
DESIGN: CGP
DRAWN: ATD
CHECK: JGG
JOB NO: 20412.10
DATE: 1 2/30/2020
Z
�_
�_
0
a
O
N
W
�
Z
�
�
W
�
Q
W
N
Z
W
J
a
N
�
�
�
(Y
Z
N
�
�
�
�
W
N
0
2
N
W
SHEET:
S1.1
N
�..1..�
O
Z
w
a
Z
J
RECEIVED
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PLAN NOTES
FOUNDATION PLAN NOTES:
1. REFER TO SHEET S3.1 FOR FOUNDATION DETAILS.
2. PLACE ALL REINFORCEMENT PER THE PLAN. REFER TO SHEET 51.1 FOR ADDITIONAL CONCRETE DETAILING
REQUIREMENTS.
3. REFER TO UPPER FLOOR LEVEL FRAMING PLAN AND SHEAR WALL SCHEDULE FOR LOCATION OF SHEAR WALL
ANCHOR BOLTS. ANCHORAGE ATNON-SHEAR WALLS SHALL BE PER STRUCTURAL NOTES.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, WALL LOCATIONS, AND CONCRETE ROUGH OPENINGS WITH
ARCHITECTURAL DRAWINGS AND NOTIFY ALL PARTIES OF ANY DISCREPANCIES.
5. CONTRACTOR SHALL PROVIDE FOOTING SUBSTRATE PREPARATION.
TYPICAL FLOOR FRAMING PLAN NOTES:
1. FLOOR SHEATHING SHALL BE 3/4" PI 48/24 WITH 10c� COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM
BOUNDARIES, PANEL EDGES AND SHEAR WALLS AND 10" OC AT INTERMEDIATE FRAMING. FOR SHEATHING
LAYOUT AND NAILING REFER TO DETAIL 2/S4.1
2. COLUMNS AND BEARING WALLS SHOWN ON PLANS SHALL BE CONTINUED DOWN TO THE FOUNDATION
UNLESS CARRIED BY A BEAM BELOW.
3. ALL DIAPHRAGMS UNBLOCKED UNO.
4. REFER TO SHEET S4.1 FOR TYPICAL FLOOR FRAMING DETAILS.
5. CONTRACTOR SHALL HAVE THE OPTION TO DRILL A 1 1/2"� HOLE CENTERED IN THE DEPTH AND AT THE THIRD
POINT OF THE SPAN FOR ALL WOOD FLUSH BEAMS SHOWN ON THE PLAN.
6. WALLS SHOWN ON THE FRAMING PLANS ARE WALLS BELOW THE FRAMING LEVELS INDICATED. HOEDOWNS
SHALL BE PLACED AT THE BASE OF THE WALLS SHOWN.
7. TYPICAL HEADERS AT BEARING LOCATION SHALL BE 4x8 HF#2 UNO SUPPORTED BY A MINIMUM OF (1) CRIPPLE
STUD AND (1) FULL HEIGHT STUD.
8. COLUMNS NOT OTHERWISE SHOWN OR CALLED OUT ON PLAN SHALL BE (2) 2x STUDS.
9. UNLESS NOTED OTHERWISE ALL STUDS SHALL BE HF STUD GRADE AND SPACED AT 16" OC.
10. UNLESS NOTED OTHERWISE, ALL BEAM -TO -BEAM CONNECTIONS SHALL BE SIMPSON HU SERIES FACE MOUNT
HANGERS W/ MAX NAILING.
TYPICAL ROOF FRAMING PLAN NOTES:
1. WALLS SHOWN ON ROOF FRAMING PLAN ARE WALLS BELOW ROOF FRAMING.
2. BEAMS SHOWN ON ROOF FRAMING PLAN SHALL BE ABOVE DOUBLE TOP PLATE UNLESS USED AS A DOOR OR
WINDOW HEADER. TRUSS MFR SHALL DESIGN TRUSSES TO ACCOMMODATE BEAMS ABOVE DOUBLE TOP PLATE.
3. ROOF SHEATHING SHALL BE 7/16" PI 40/20 WITH 8d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM
BOUNDARIES, PANEL EDGES, SHEAR WALLS, COLLECTOR TRUSSES, AND BLOCKING OR TRUSS BLOCKING PANELS
INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC. REFER TO
DETAIL 2/S4.1 FOR SHEATHING LAYOUT AND NAILING.
4. UNLESS NOTED OTHERWISE, HEADERS AT ALL EXTERIOR WALLS SHALL BE 4x8 HF#2 WHERE MAXIMUM
SPAN = 6'-0".
5. UNLESS NOTED OTHERWISE, DOOR HEADERS AT INTERIOR BEARING WALLS SHALL BE 4x8 HF#2 WHERE
MAXIMUM SPAN = 4'-6", AND 6x8 HF#2 WHERE MAXIMUM SPAN = 5'-0".
6. STUD WALL FRAMING SHALL BE 2x HF STUDS @ 16" OC FOR ALL STUD WALLS SHOWN ON THE PLAN.
7. REFER TO SHEET 55.1 FOR TYPICAL ROOF FRAMING DETAILS.
8. REFER TO DETAIL 8/54.1 FOR CONSTRUCTION OF MULTIPLE STUD COLUMNS.
9. REFER TO THE STRUCTURAL NOTES SHEET FOR COLUMNS SUPPORTING TYPICAL BEARING WALL HEADER
BEAMS.
10. ALL DIAPHRAGMS UNBLOCKED UNO.
11. COLUMNS AND BEARING WALLS SHOWN ON PLAN SHALL BE CONTINUED DOWN TO THE FOUNDATION UNLESS
CARRIED BY A BEAM BELOW.
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
12/ 30/ 2T0
J
Q
F-
Z
O m
� �
�_ N
� ~
C)
(n �
w w
� a
O
W �
Q O
� �
N
r-I
DESIGN: CGP
DRAWN: ATD
CHECK: JGG
JOB NO: 20412.10
DATE: 1 2/30/2020
w
U
W
0
W
`fir,
w
2
e
z
J
Y
(n
N
N
SHEET:
�•
N
Q w
0
(� Z
0
Z Z
O Q
�
Q �
w
a
W �
J
S1.2
RECEIVED
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
}
- � .. ..
E. ..
9
.._ �.
_ _
HO.DOWN SCHEDULE
HO.DOWN SCHEDULE
MARK
TYPE
MIN CHORD SIZE
STUD NAILS OR BOLTS.
ANCHOR BOLT. +
CAPACITY (LB}
1
F1AD4.15i
� (2) 2x
(14) SDS 1/4;" x 2 -1/2" SCREWS
S/8" DIA
4,340
2
HbU8
4X QF#2 :
(20) SDS 1/4" x2 -k/�" SCR
°/8" DIA
6,970
;,_. ,
NOTES: ... _ ,
1. REFEtt.l'Q THE LATEST SIMPSON STRONG -TIE CATALOG FOR �DI'F10NAL INSTALLATION REQUIREMENTS.
3; 116fi5TAtCL HD HOLOCR#Ifl�[S AT FOUNDATION WALLS PER DETAN. i/53:1.
4 A1'ALL HOEDOWN CHORDS, PROVIDE PANEL EDGE NAILING PER SHEAR WALL SCHEDULE.
F
. s
. ;.
.. , , r .,.. _.. �„r.., _,.��.. _
��
,..
PAD
SCHEDULE
', q %�itl�
SIZE
REINFORCING
qi
2' - 0" SQ X 10" DEEP. ..
? (3} #4 Afi BOTTgMI EA WAY UNDER jE) FOOTING
g
3' - 0" SQ X 10" DEEP
(4) #4 AT BOTTOM EA WAY UNDER (E) FOOTING ,
C ..
3' - 6" SQ X 10" DEEP
(4} #4 AT BOTTOM EA WAY UND€R (E} FbC�TING
L't
4' - 0" SQ X 10" DEEP
(5) #4 AT BOTTOM EA WAY UNDER �E) FhSSOTtNG
Ndiffi
1.(:iFFSETPADS TO THE INTERIOR OF THE GARPtCiE AS SHOWN TO MINIMIZE DEMOLITION OF EkISTMG DRIVEWAY
�. PADS"MAY BE 1�OURED AT THE SAME LEVEC'AS THE EXISTING FOOTINGS PROVIDED THATTHE REQUIRED REINF
IS DRILLED THRU THE FOOTINGS AND EPDXIED INTO PLACE WITH SIMPSON SET XP EPDXY. (TYPICAL)
% I I
DC�` � �J
VERIFY EXISTING GARAGESTEIVIWALLSWEREP(3lfREDINTEGRALLYWITHEXISTING
���� BASEMENT WALLS AND TWERE I� HORIZONTAL R�BAR TYING TH EM TOGETHER. �
%�;�{,?(J'�- FGARAGEWAI�ISAREIVOTTIEDTOBASEMEN�'WALLSTHENDRILLAI�DEPDXY. _ ._
��
�� ��� {3) 3/4" DIAX 24" THREADED RODS THRU EXISTING BASEMENT.WALLS AND ' i�
INTO GARAGE FOOTING AND STEM WALLS WITH (2.) BARS INTO EACH FC►OTING AN �../. � .
(1) BAR INTO EACH STEM WALL. SECURE BASEMENT -WALL WITH 1/4" X 4" X 4" m■rri�:
�i
PLATE WASHER AND NUT. (TYPICAL AT(2) LOCATIONS).
"� � ..
—� W
��°
C C 2S0 4TH AVE S. STE 200
EDMONDS, WA 98020
ENGINEERING 425.778.8500
STRUCTURAL REVIEW
THIS DRAWING HAS BEEN REVIEWED
FOR CONFORMANCE WITH
STRUCTURAL REQUIREMENTS .
INDICATED IN THE ATTACHED LETTER
AND/OR CALCULATIONS.
BY..Joe Galusha, PE, SE,
JOB #: 20412.10 DATE: �zisoizozo
SHEAR WALL SCHEDULE
'
Af>A-RATED
MIN FRAMING AT
SHEAR WALL NAILING AT PANEL
RIM JOIST OR
SILL PLATE NAILING
SILL PLATE ANCHOR �
FOUNDATION
SHEAR
MARK
ADJOINING PANEL
BLOCK CONN TO
TO RIM/BLKG ;
: Bc>LTTO-SLAB OR
CAPACITY
SHEATHING
EDGES {SEE NOTE 5)
EDGES
TOP PLATE
BELOW
1NDATION
SILL PLATE SIZE
PLF
15/32"
3x STUD AND 2x
LTP4 OR A35 @
0.131" DIAx 3 @
2
0.131"DIAx 2 1/2" @ 2"�
"��$" DIA AB @ 2'-Gs" ice`
2x
595
ONE E
FLAT BLKG
12' OC
2.5
15/32"
(2) 2x STUD
LTP4 OR A35 {1
0.131" DIA x �'" �
3 :.
0.131' DIAx 2 1/2" @ 3"OC
5�$" DIAAf3 @ 3'-0" OC
2x
455
ONE SIDE
AND 2x FLAT BLKG
15" OC
3' OC
15/32"
2x STUD
LTP4 OR A35 �
0.131 DIAx 3" @
'4"
4
0.131"DIAx 2 1/2" @ 4"OC
�/8" DIA AB @ 4'+fl" OC
�x
350
ONE SIDE
AND BLKG
20" OC
OG .
_-.
15%32"
2x STUD
LTP4 OR A35 @
0.131" DIAx 3" @
6
0.131°'DIAx 2 1/2" @ 6"OC
5%8" DIA AB @ 5'-0'° OC
2x
242
NOTES:
1, REFER TO THE TYPICAL SHEAR WALL DETAILS FOR MORE INFORMATION.
2, THE VALUES IN THIS TABLE ARE APPROPRIATE FOR Hf GRADE STUDS AND HF GRADE PLATES &RIM/BLOCKING.
3. NAILS AT ADJOINING PANEL EDGES SHALL BE STAGGERED EACH SIDE OF THE COMMON JOINT.
4. WHERE PANELS ARE APPLIED ON BOTH FACES OF A WALL, PANEL JOINTS SHALL BE OFFSETTO FALL ON DIFFERENT FRAMING MEMBERS, ORFRAMq�iG SWAiL
BE3x ATAD101NING PANEL EDGES AND NAILS SHALL BE STAGGERED.
S. WHERET�LE SPECIFIES (2) 2x FRAMING, CONNECT (2) 2x STUDS AND BLOCKING AS FOLLOWS: SW3 = (2j 0.131 DIA @3.5" O.C.
6. NOTE THAT3x FRAMING MAY BE USED IN LIEU OF (2) 2x FRAMING SPECIFIED IN TABLE
7. INTE1tMEDIATE FRAMING TO BE WITH 2x MINIMUM MEMBERS. FIELD NAILING 12" O.C. MAXIMUM
8. AT ALL 5/8" DIA SILL PLATE ANCHOR BOLTS, INSTALL 1/4" x 3" x 3" PLATE WASHERS. EDGE OF PLATE W1�HIS SHl�tt t31` WITHIN 1/2" OF SHEATHIt> EDGE.
9. PROVIDEA-MiNIMUM OF 7" EMBEDMENT FOR AB INTO FOUNDATION OR STEM WALL.:
10.7/lb" tSHEATHiNG MAY Bf JD �I 1�LACE OF 15/32" SkIEATHING PROVIDED ALL STIJEDS ARE SPACED 16" EL.�.-AR RANELS ARE 11PPLtED {!WITH LONG
DIMENSION CROSS STUDS. $
11. IN LIEU OF EMBEDDED ANCHOR BOLTS, CONTRACTOR MAY PROVIDE SIMPSON TITEN HD SCREW ANCHORS @ fiHE SAME SPACING WJ �" EM$EDfiIIENT,
OR 5/8" ®IA THREADED RODS @THE SAME SPACING W/ SIMPSON SET-XP EPDXY W/ 7" EMBEDMENT.
N �-
C � 250 4TH AVE S. STE 200
E4MOND5, WA 98020
ENGINEERING 4as.��a.8soo
STRUCTURAL REVIEW
THIS DRAWING HAS BEEN REVIEWED
FOR CONfORMANCE WITH
STRUCTURAL RECZUIREMENTS
INDfCATED IN THE ATTACHED LETTER
AND/OR CALCULATIONS.
BY: Joe Galusha, PE, SE, `
JOB #: 20412.10 DATE �zisoi2o2o
SYMBOLS
SCHEDULE �.
FOOTING C3A'PA
STEM, BEARING
OR SHEAR WALE
�
POST BELOW . ' ;
0
P'OST� ABOVE
pO�T� ABOVE �
B"FLOW '
has: o''r 1-JOIST
FRAMING
P�E`M'A N U F
-` —`—
TRUSSES
H EA-R _.WALL
CALL�UT
LLJ: ;
o
_.
CV
� .'
.:..
y
�:�::'M
�
�.�
�
C
� -
O
;�
�� :;. .
�: �
W`�
:..� .
�
'� V
�
N
}i
�, � .
'a
��. �
!�
', N
�.
L�J',� .
C
o
rr� �
Jtt:
W
iVtt
k�.�l'-
�
'0
T
�.
�;
C33
��.
�
Z
W
��
�..
W
J
_.....
�
Y
d^
CV .
N
1�4.DDOVVIV
G/4LL�UT
RECEIVED
� � I�A�cR
DPc 31 2020
Sl`RJ®tP
` - � � �
- CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPhRTMENT
O GI
THREADED ROD AS REQ'D
PER PLAN. INSTALL
W/ SIMPSON SET-XP
EPDXY
EXIST CONC
STEM WALL
TOP OF FTG
HOEDOWN
PER PLAN
AND
SCHED
SHEAR WALL PER
PLAN AND SCHED
HOEDOWN DETAIL (EXIST FOOTING
SCALE: 1" = 1'-0"
STUD WALL PER
FRAMING PLAN NOTES
SHEATHING AND NAILING
PER PLAN AND SHEAR
WALL SCHEDULE
PAVING OR
FINISHED GRADE �
NEW OR EXIST STUD
WALL PER PLAN
SIMPSON TITEN HD
ANCHOR BOLTS, SIZE
AND SPACING PER
SHEAR WALL SCHED
X X
�� °O
0 0 °op �Oo
O Op° oO Dooms
EXIST STEM
OO OO O p WALL PER PLAN
0
O o °� o p0
O ° '���
00 00 � O
OOoO� �O
EXIST FTG
PER PLAN
EXISTING STEM WALL SECTION
SCALE: 1" = 1'-0"
(4) #4 HOOKED
m DOWELS
6" nl
��
= a
J
d d
W
� d
M U
SIZE AND REINF
PER PLAN
COL PER PLAN
SIMPSON ABU
POST BASE
8" x 8" CONCRETE
PLINTH W/ #3
TIES @ 3" OC
FINISHED GRADE
OR CONCRETE
SLAB PER PLAN
ISOLATED POST FOOTING
SCALE: 1" = 1'-0"
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
12/ 30/ 2020
J
Q
z
O
m
�
N
�
~
U
(�
�
LLJ
W
�
d
W
\
O
Q
�
�
N
r-I
Y
Q
DESIGN: CGP
DRAWN: ATD
CHECK: JGG
JOB NO: 20412.10
DATE: 1 2/30/2020
Z
�_
I--
0
�
a
O
N
w
o
z�
�
w
�
p
Q
w
�
N
z
W
J
a
N
�
�
�
(Y
Z
N
�
�
�
�
W
N
0
2
N
W
SHEET:
■
REC IVED
nP� . � �n�n
Q
w
0
Z
O
Q
0
Z
O W
a
J
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
STAGGER NAILS ON EA SIDE
OF PANEL JOINT AS REQUIRED
PER SHEAR WALL SCHED
I•I
II
II
I•I
II
II
HEADER PER PLAN
II
II
� I I
II
II
I I
I•I
I•I
• I
I I I
I I
I
I
I I I
II
I I
II
I
I
I
CRIPPLE STUDS PER
I
.II
I I
I I j
I I
I
I
I
PLAN; DO NOT CUT
IIII
I•I
I•I
I
I•
AWAY MATERIAL FROM
I
I•
I I
I I
I•
I I
CRIPPLE STUDS
j
II.11
I
II
I I
11
II
I I
II
II
I •I
I�
I
I
I
I I
IIII
III
11
I•I
II
I.I
I•I
I
II
I I.I
FULL -HEIGHT
I
I•I
I I I
I I
I•
I I I
HOEDOWN CHORD
IIII
IIII
II.11
I I
11
II
I I
II
I •I
I
I I
I II
I II
Ili
I I
11
I•I
II
II
I•I
I�
I'i
I,
i.
I
I I
I I I
I I
I
I I I
IIII
IIII
II.11
II
11
II
II
II
II
I•I
I,
11
I II
I II
I l
I I
i I I
I•I
I I
I•I
I
I•
I,
I I• I
I
I I
I I I
I I
I
� �
II
11
II
I I
I•I
I.
II
AB W/ SIMPSON BP
I
I
I I
I
•I
I 11
I I I
PL WASHER, TYP
I•I
II
I
I•I
I II
II
I I
I�
I•I
I
11
I I I
PT SILL PL PER SHEAR
I I
I�
I I I
WALL SCHED
•I
A I I
I•I
I
I
I
I.I
II
II
1------1
I�
-- —
J1
II _ z
II
II
II � �
I I
II
II
-1 I
CONCRETE FOOTING
I III-
AB SIZE AND SPACING
A ' I-1
OR P/T SLAB
PER PLAN AND SHEAR
WALL SCHEDULE, TYP
NOTES:
1. REFER TO STRUCTURAL NOTES FOR
ADDITIONAL INFORMATION.
2. FOR SHEAR WALLS WHERE NO HOEDOWNS
ARE SPECIFIED THE FIRST AB SHALL BE
LOCATED NOT MORE THAN 1'-0" AND NOT
LESS THAN (7) BOLT DIAMETERS FROM END
OF WALL.
TYPICAL SHEAR WALL DETAIL
SCALE: 3/4" = 1'-0"
------rl-------n-------rl-------rl-----rl�
I'I I'I I'I I•I I I•I
II II II II III
II II II II III
I I I I I I I I I
II II II II III
II II II II III
I'I I'I I'I I•I I I.
II II II II I I
I II II �I III
I FRAMING AT ADJOINING I•I
I I PANEL EDGES PER SHEAR j l I C I
I'I WALL SCHED •I
II 11 III
II II II II 11•I
II II II II III
II II II II
I'I I•I I•I I•
II II II
II II
_J L �-- ;--H•F— ;-- ;—H F•---•--
-� r------ i i------ i i-----
•i I•I I•I
II II II
II II II
II II II
II II II
II II II
I'I I•I I•I
II II II
II II II
II II II
II II II
II II II
I'I I•I I•I
II II II
II II II
II II II
II II II
II II II
I'I I•I I•I
II II II
__ II II
_1L------1L------1
------
II II I
II II II
II II II
II II II
1L_�_ � 1L� __� __1
- II II //
II II I(
� RIM BOARD � �\
\�
OR BLOCING /1
ii
PANEL EDGE NAILING
PER SHEAR WALL
SCHEDULE, TYP
PANEL EDGE NAILING INTO
HOEDOWN CHORDS, TYP
INTERMEDIATE
NAILING @ 12" OC
SHEATHING PER PLAN AND
SHEAR WALL SCHEDULE
HOEDOWN CHORD PER
SCHEDULE. REFER TO
TYPICAL BUILT-UP
COLUMN DETAIL
ADDITIONAL END STUD
IF REQUIRED TO
PROVIDE
COUNTERSINK FOR
HOEDOWN BOLTS
HOEDOWN ANCHORAGE
PER PLAN AND SCHEDULE
SIMPSON CNW COUPLER 1/2" TO
NUT W/ SIZE TO MATCH SHEATHED EDGE
HOEDOWN ANCHORAGE
PANEL EDGE
NAILING PER SHEAR
WALL SCHED
CONTINUE HOEDOWN CHORD
TO FOUNDATION
CONCRETE STEM WALL
CONCRETE FOOTING
STUD WALL PER
FRAMING PLAN NOTES
SILL PLATE NAILING
SHEATHING AND
PER PLAN AND SHEAR
NAILING PER PLAN AND
WALL SCHEDULE OR
SHEAR WALL SCHEDULE
STRUCTURAL NOTES
OR STRUCTURAL NOTES
SHEATHING AND
BREAI<SHEATHING
NAILING PER PLAN
AT PLATE UNO
1 1/2" TOPPING
�
SLAB W/ FIBER
1 1/2" LSL RIM
MESH ADDED TO
SILL PLATE NAILING PER
THE CONCRETE
SHEAR WALL SCHEDULE
MIX
BREAK SHEATHING
AT PLATE UNO _�
PANEL EDGE NAILING
PER PLAN AND SHEAR
WALL SCHEDULE OR
I -JOISTS PER PLAN
STRUCTURAL NOTES
AND SCHEDULE
2x4 BLOCKING AT
SHEAR WALLS
NOTE:
SAWCUT EXIST STUDS AND
NON -SHEAR WALL
,, PROVIDE NEW DOUBLE TOP PLATE
NAILING SHALL BE PER
�/�" EXIST STUD WALL
IBC TABLE 2304.9 A. TYPICAL
FRAMING
TYPICAL STU D
WALL FRAMING DETAI L
SCALE: 1" = 1'-0"
1 1/2" LSL RIM
JOIST
PLATE WASHER
PER SHEAR
WALL SCHED
SECTION A -A
SCALE: 1 1/2" = 1'-0"
NOTE:
STAGGER SHEATHING
AS SHOWN. (IBC TABLE
2306.3.1, CASE 1 OR 3)
INTERMEDIATE
FRAMING MEMBERS
SHEATHING
PANEL, TYP � � , ,
CONTINUOUS
PANEL EDGES
SUPPORTED
PANEL EDGES
2x OR 3x BLOCKING ONLY IF
n� �i-vrr� r�i n n� in n �n n it �nr ��r�rr�
`L DIAPHRAGM BOUNDARY
(SHEAR WALL, BEAM, OR DRAG STRUT)
TYPICAL FLOOR/ ROOF SHEATHING DETAIL
SCALE: NTS
SIMPSON A35 (ONLY
REQUIRED AT EXTERIOR
HEADERS GREATER
THAN 6' SPAN)
(6) 0.131"� x 3" NAILS
TYPICAL STUDS
NAILING PER TYP
BUILT-UP STUD
COLUMN DETAIL
AT HOEDOWNS: PROVIDE FULL HT
HOEDOWN CHORDS PER HD SCHED
OTHERWISE: (1) 2x FULL HT
TYPICAL HEADER DETAIL
SCALE: 1" = 1'-0"
NOTE:
FOR NOTES AND DETAILS
NOT CALLED OUT REFER
TO DETAIL 6.
(4) 10d NAILS
1 1/2" TOPPING SLAB
W/ FIBER MESH
ADDED TO THE
CONCRETE MIX
SAWCUT EXIST
STUDS AND
PROVIDE NEW (3) 0.131"� x 3"
DOUBLE TOP NAILS EACH END
PLATE
I -JOISTS PER PLAN
AND SCHEDULE
1 1/2" LSL BLOCKING
EXTERIOR WALL PARALLEL TO JOISTS @ 4'-0" OC MAX
TYPICAL STU D WALL FRAMING DETAI L
• l SCALE: 1" = 1'-0"
DECK
SURFACING
PER ARCH
RIPPED 2x SHEATHING AND
OVERFRAMING NAILING PER SHEAR
@ 16" OC � WALL SCHEDULE
2x LSL BLKG J
DECK FRAMING OPTION A
DECK OVERFRAMING SECTION
SCALE: 1" = 1'-0"
NOTE:
SUPPORTS AT SOLID
POSTS SIM
BEAM PER
AND SCHE
SIMPSON LTP4 C
A35 FRAMI�
ANCHOR EACH SII
OF BEA
ADJACENT NAILS IN A
ROW ARE TO BE
DRIVEN FROM
OPPOSITE SIDES, TYP
FOR 2x4 STUDS, PROVIDE SINGLE
ROW OF NAILS STAGGERED EA SIDE
WITH 1 1/2" EDGE DISTANCE. FOR
2x6 STUDS, PROVIDE (2) ROWS OF
NAILS SPACED AT 2 1/2" W/ 1 1/2"
EDGE DISTANCE
9" OC MAX SPACING BETWEEN
ADJACENT NAILS IN A ROW
0.131"� x 3" NAILS, TYP
(5) STUDS MAX TO
BE USED FOR
BUILT-UP COLUMNS
TYPICAL BUILT-UP STUD COLUMN DETAIL
v l SCALE: 1" = 1'-0"
TYP DOUBLE � EDGE NAILING PER PLAN
TOP PLATE AND SHEAR WALL
SCHEDULE OR EDGE NAILING PER PLAN
STRUCTURAL NOTES, TYP AND SHEAR WALL
0.131"S6 x 3" SCHEDULE OR
NAILS @ 9" OC STRUCTURAL NOTES, TYP
BEAM OR HEADER PER
PLAN AND NOTES
CRIPPLE STUDS PER PLAN
AND COLUMN SCHEDULE OR
STRUCTURAL NOTES
(2) ROWS OF 0.131"� x 3"
NAILS @ 9" OC
STUD WALL PER
FRAMING PLAN
NOTES, TYP
SHEATHING (OR GWB) AND
NAILING PER PLAN AND SHEAR
WALL SCHEDULE OR
STRUCTURAL NOTES, TYP
A. CORNER INTERSECTION
0.131"� x 3"
NAILS @ 9" OC
STUD WALL PER
FRAMING PLAN
NOTES, TYP
2x6 STUD @ 2x4 CROSS WALL
2x8 STUD @ 2x6 CROSS WALL
B. 'T' INTERSECTION
TYPICAL WALL INTERSECTION DETAIL
SCALE: 1" = 1'-0"
BEAM PER PLAN
AND SCHEDULE
JOIST DIRECTION
PER PLAN
STUD WALL
SOLID OR MULTIPLE � '� WIDTH, �
STUD COLUMN PER PLAN MIN UNO
PARALLEL TO STUD WALL
1 TYPICAL FLUSH BEAM SUPPORT DETAILS
v J SCALE: 1" = 1'-0"
� NOTE:
SILL PLATE NAILING FOR NOTES &DETAILS NOT
PER SHEARWALL SHEATHING SPECIFICALLY CALLED OUT
SCHEDULE AND NAILING REFER TO DETAIL 6.
PER NOTES
5 1/2" x 11 7/8" PSL
RIM BEAM 1 1/2" TOPPING
a SLAB W/ FIBER
- MESH ADDED
TO THE
2x BLKG W/ 10d @ CONCRETE MIX
6 OC NAILING
2x LSL BLKG �
JOISTS PER PLAN J
A35 CLIPS PER SHEAR
WALL SCHEDULE
SOLID
STUD COLU,.,,. , ". , ��,.
PERPENDICULAR TO STUD WALL
EDGE NAILING PER
PLAN AND SHEAR
WALL SCHEDULE
OR STRUCTURAL
NOTES, TYP
SHEATHING (OR
GWB) AND
NAILING PER PLAN
AND SHEAR WALL
SCHEDULE OR
STRUCTURAL
NOTES, TYP
SIMPSON A35 EACH
`SIDE OF BEAM
I
�n
=
O
�
a
�
J
w
DECK
"
SURFACING
SILL PLATE NAILING SHEATHING
PER ARCH
PER SHEARWALL AND NAILING
RIPPED 2x
SCHEDULE PER NOTES
SHEATHING AND
OVERFRAMING NAILING PER SHEAR
5 1/2" x 11 7/8" PSL
@ 16" OC � WALL SCHEDULE
RIM BEAM
a
2x OVERFRAMING
@ 16" OC
JOISTS PER PLAN J BEAM PER PLAN
2x LSL BLKG
A35 CLIPS PER SHEAR
DECK FRAMING OPTION B WALL SCHEDULE
STU D
WALL
1 1/2" TOPPING
SLAB W/ FIBER
MESH ADDED TO
THE CONCRETE
MIX
o �I
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
12/ 30/ 2020
J
Q
H
Z
O
m
�
�
D_
N
�
�
C�
�
(n
�
W
LLI
0
a
O
W
�
O
Q
�
�
N
Y
Q
DESIGN: CGP
DRAWN: ATD
CHECK: JGG
JOB NO: 20412.10
DATE: 1 2/30/2020
Z
�_
�_
0
�
Q
o
N
W
�
Z
�
�
�.IJ
Q
W
Z
W
J
a
(�
Z
N
0
�
�
�
W
N
0
2
N
W
SHEET:
S4.1
REC IVED
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
O C
2x6 CONTINUOUS
RIDGE BOARD, TYP
ROOF SHEATHING AND
DIAPHRAGM BOUNDARY NAILING PER ROOF
NAILING PER ROOF FRAMING PLAN NOTES
FRAMING PLAN NOTES �
FULL DEPTH BLKG RIPPED
TO MATCH SLOPE OF ROOF
r / � ROOF RAFTERS
Ir/ PER PLAN
PROVIDE BOUNDARY 2x4 BLKG W/SILL PL
NAILING AT TOP PLATE PER NAILING PER SHEAR
SHEAR WALL SCHEDULE WALL SCHED 2x NAILER W/ (2) 16d
@ EACH RAFTER
SIMPSON H2.5A TIE
SHEATHING AND NAILING
PER PLAN AND SHEAR STUD WALL FRAMING
WALL SCHEDULE PER PLAN NOTES
TYPICAL RAFTER SUPPORT DETAIL
SCALE: 1" = 1'-0"
SIMPSON A35
EACH RAFTER
16d @ 6" OC
2x6 RAFTERS
@ 24" OC
2x4 VERTICAL SUPPORT
MEMBERS SPACED @
2'-0" OC ALIGN W/ EA
RAFTER BELOW TYP , .
NOTE:
PROVIDE BLOCING @
ALL EDGES &SUPPORTS
STICK FRAMED OVERFRAMING DETAIL
SCALE: NTS
SHEATHING AND NAILING PER
ROOF FRAMING P' ""' "'^T�`
2x FLAT Ol
SILL PLATE f
PER SV�
SHEATHI�
NAILING PER PLP
SHEAR WALL
FULL HEIGHT
AT GAB
RAFTER GABLE END
SCALE: 1" = 1'-0"
SHEATHING AND NAILING PER
ROOF FRAMING PLAN NOTES
RAFTERS PER PLAN
SECTION
SCALE: 1" = 1'-0"
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
2x RIDGE BLOCKING ATTACH RAFTERS TO BEAM
W/ PANEL EDGE NAILING W/ 3/16" x 10" TIMBERLOI<TRUSS
ROOF RAFTERS SCREW COUNTERSUNK, 2" EMBED MIN
PER PLAN SIMPSON A35
EA SIDE ROOF SHEATHING
PER PLAN &NOTES
$� � G ' GAL
o� wash► ��
E`° � o,
�0 ��9L 3�15
BEAM PER PLAN S`SIONAL
12/ 30/ 2020
IUNG POST OR
COLUMN BEYOND
SECTION AT ROOF RIDGE BEAM
4 SCALE: 1" = 1'-0"
J
z
c�
G
O
m
�
�
�
N
CY
U
�
ROOF SHEATHING AND
�
w
�
w
DIAPHRAGM BOUNDARY NAILING PER ROOF
�
�
NAILING PER ROOF FRAMING PLAN NOTES
FRAMING PLAN NOTES
O
N
FULL DEPTH BLKG RIPPED
�
O
EXIST SHEATHING TO MATCH SLOPE OF ROOF
�
N
Y
Q'
ROOF RAFTERS
PER PLAN
Q
2x4 BLKG W/ 16d @ 6" OC
DESIGN: CGP
16d @ 6" OC
EXIST OVERHANG ATTACH RAFTER TO BEAM
DRAWN: ATD
OUTLOOI<ER W/ TIMBERLOCK 10" TRUSS
CHECK: JGG
SCREW AND 2" OF THREAD
2x10 HF#2 EMBEDMENT MIN
JOB NO: 20412.10
BEAM PER PLAN
DATE: 1 2/30/2020
TYPICAL RAFTER SUPPORT DETAIL
SCALE: 1" = 1'-0"
N
�
Z
O
Q
�'
p
W
p
0
Q
O
N
w
�
C�
Z
Z
�
�
W
p
�
�
W
�
Q
N
Z
�
�
(n
�
�
�
N0
Z
�
�
�
�
�
W
N
p
O
Q
=
N
W
�
�
SHEET:
S5.1
RECEIVED
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT