BLD2020-1418+Energy_Calculations+12.30.2020_4.34.21_PM+1968512BLD2020-1418 RECEIVED Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U- factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Herzig Addtion Phillip "Skip" DeHennis 224 Skyline Dr 10016 Edmonds Way#C229 Edmonds WA 98020 Edmonds, WA 98020 in Heating System Type: t♦ All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Instructions Design Temperature Difference (AT) Edmonds Wo A = Indoor (70 degrees) - Outdoor Design Temp Area of Buildina Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions Skylights Instructions Insulation Attic Instructions Select R-Value Ell Single Rafter or Joist Vaulted Ceilings Instructions R-38 Vented Ell Above Grade Walls (see Figurer) Instructions R-21 Intermediate Floors Instructions R-38 Below Grade Walls (see Figure 1) Instructions Select R-value Slab Below Grade (see Figurer) Instructions Select conditioning Slab on Grade (see Figurer) Instructions Select R-Value Location of Ducts Instructions No Ducts Fi ure 1. Above Grade 678 Conditioned Volume 9.0 6,102 U-Factor X Area = UA 0.30 293 87.90 U-Factor X Area = UA 0.50 --- U-Factor X Area = UA No selection 0 --- U-Factor X Area UA 0.027 678 18.31 U-Factor X Area UA 0.056 864 48.38 U-Factor X Area UA 0.025 678 16.95 U-Factor X Area UA No selection 0 --- F-Factor X Length UA No selection 0 F-Factor X Length UA No selection 0 --- Duct Leakage Coefficient 1.00 Sum of UA 171.54 Envelope Heat Load 7,891 Sum of UAX AT Air Leakage Heat Load 3,031 VolumeX 0.6XATX.018 Building Design Heat Load 10,922 Air Leakage + Envelope Heat Loss Building and Duct Heat Load 10,922 Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space., Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 15,291 Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump 46 Btu / Hour Btu / Hour Btu / Hour Btu / Hour Btu / Hour Dec 31 2020 CITY OF EDMONDS EVELOPMENT SERVICES DEPARTMENT (07101113)