REVIEWED BLD2021-0271+Structural_Analysis_or_Calculations+5.24.2021_5.59.34_PM+22143736ENERAL 57RZ7JRAL N07E5 1. CRITERIA: ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC). 2. DESIGN LOADING CRITERIA: ROOF SNOW LOAD EXHAUST FAN MAKE UP AIR UNIT 11' TYPE I KITCHEN HOOD 6' TYPE I KITCHEN HOOD WIND ANALYSIS PROCEDURE: RISK CATEGORY II BASIC WIND SPEED 97MPH WIND EXPOSURE "B" TOPOGRAPHIC FACTOR Kzt = 25 PSF 93 LBS 668 LBS 419 LBS 279 LBS ASCE7-16 CHAPTER 29 "OTHER STRUCTURES" no EARTHQUAKE ANALYSIS PROCEDURE: ASCE7-16 " NONSTRUCTURAL COMPONENTS" SEISMIC DESIGN CATEGORY (SDC) = D RISK CATEGORY = II SEISMIC SITE CLASS = D IMPORTANCE FACTOR le = 1.0 MAPPED MCE Ss = 1.29; S1 = 0.45 DESIGN ACCELERATION Sds = 1.03; Sd1 = 0.56 COMPONENT AMPLIFICATION FACTOR ap = 2.5 COMPONENT RESPONSE MODIFICATION FACTOR rp = 6.0 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THEIR WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. WHERE INFORMATION ON THE DRAWINGS IS IN CONFLICT WITH THE SPECIFICATIONS, THE MORE STRINGENT SHALL APPLY, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. DO NOT SCALE THE DRAWINGS. 9. TIMBER: (N) 2-2xl2 w/ .,,. . -. - PLAN NOTES: REPRESENTS EXHAUST FAN PER MECHANICAL DRAWINGS. MAX. WEIGHT=93#, TYPICAL (2) LOCATIONS. FINAL PLACEMENT PER MECHANICAL (10' MIN. TO ANY AIR INTAKE AND PROPERTY LINE IN ANY DIRECTION; 10' MIN. FROM SAME OR ADJACENT BUILDING). REFERENCE DETAILS 5/S-2 & 9/S-2 FOR CONNECTION. 2. HD- REPRESENTS HOOD PER MECHANICAL DRAWINGS. MAX. WEIGHT=419#, TYPICAL (2) LOCATIONS. FINAL PLACEMENT PER MECHANICAL. REFERENCE DETAIL 10/S-2 & 14/S-2 FOR HOOD SUPPORT CONNECTION. 3. MAU- REPRESENTS MAKE-UP AIR UNIT PER MECHANICAL DRAWINGS. MAX. WEIGHT=668#, TYPICAL (1) LOCATION. FINAL PLACEMENT PER MECHANICAL (10' MIN. FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE). REFERENCE DETAIL 13/S-2 FOR CONNECTION. 4. HANG KITCHEN HOODS WITH Y" O ALL -THREAD ROD, VERIFY LOCATIONS WITH MECHANICAL DRAWINGS. 5. ROOF FLASHING DESIGN BY OTHERS. CONTACT ORIGINAL ROOFING CONTRACTOR FOR ROOFING WARRANTY. 6. RECTANGULAR AND SQUARE DUCTS WITH 6 S.F. AREA AND LARGER REQUIRE BRACING. EXCEPT WHEN DUCT IS LESS THAN 12" FROM SUPPORT STRUCTURE. BRACING SHALL BE AT 40'-0" TRANSVERSE (MAX.) AND 80'-0" LONGITUDINAL (MAX.) 7. ROUND DUCTS 28" DIA. AND LARGER REQUIRE BRACING. EXCEPT WHEN DUCT IS LESS THAN 12" FROM SUPPORT STRUCTURE. BRACING SHALL BE AT 40'-0" TRANS. (MAX.) AND 80'-0" LONGITUDINAL (MAX.) OOP SRAM` NIS PLAN/ ROOF TOP UNIT PLAN BEAMS (4x -AND GREATER) DF-L #2 OR BETTER POSTS DF-L #2 OR BETTER SCALE: 1 /4" = 1'-0" STUDS HF-L #2 ALL OTHER LUMBER DF #2 OR BETTER ALL 2X -__ TIMBER KILN DRIED. ALL GRADES SHALL CONFORM TO A WWPA GRADING RULES FOR WESTERN LUMBER, LATEST EDITION. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. MISCELLANEOUS HANGERS TO BE AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY, INC. OR APPROVED EQUAL. ALL HANGERS TO BE FASTENED TO WOOD WITH PROPER NAILS. ALL HOLES SHALL BE NAILED. MACHINE BOLTS TO BE A-307. ANCHOR BOLTS INTO CONCRETE SHALL BE 5/8" DIAMETER @ 48" O.C. (UNLESS NOTED OTHERWISE) WITH MIN. EMBEDMENT PER I.B.C. CODE. ALL NAILS SHALL BE COMMON WIRE NAILS. SPIKE ALL LAMINATED MEMBERS TOGETHER WITH 10d NAILS @ 12" O.C. STAGGERED. SPLICE LAMINATIONS AT SUPPORTS ONLY. 10. WOOD SHEATHING SHALL BE APA RATED, EXTERIOR GLUE; EXPOSURE 1, IN CONFORMANCE WITH THE REQUIREMENTS FOR THEIR TYPE IN DOC PS-1 OR PS-2. SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION INDEX AND NAILING REQUIREMENTS. 11. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C-C-2019. EQUIVALENT DEVICES BY OTHER MANUFACTURES MAY BE SUBSTITUTED, PROVIDE THEY HAVE I.C.0 OR IAPMO UES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. CONNECTORS SHALL BE SIZED TO MATCH THE SIZE OF THE FRAMING MEMBERS BEING CONNECTED. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURES. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. ALL BOLTS TIGHTENED TO SNUG TIGHT. MISCELLANEOUS: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT JOBSITE INCLUDING BUILDING AND SITE CONDITIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL ALLOWANCE WILL BE MADE IN THE CONTRACTOR AND/OR MANUFACTURER'S FAVOR BY VIRTUE OR ERRORS. AMBIGUITIES AND/OR OMISSIONS WHICH SHOULD HAVE BEEN DISCOVERED DURING THE PREPARATION OF BID ESTIMATE AND DIRECTED TO THE ATTENTION OF THE ARCHITECT IN A TIMELY MANNER. ANY ERRORS, AMBIGUITIES AND/OR OMISSIONS IN THE DRAWINGS OR SPECIFICATIONS SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY IN WRITING. NO WORK IS TO BE STARTED BEFORE CORRECTION IS MADE. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACINGS AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENINGS HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON THESE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND CAN BE REPRODUCED ONLY WITH THE PERMISSION OF THE ARCHITECT, IN WHICH CASE THE REPRODUCTION MUST BEAR THEIR NAMES AS ARCHITECT. PRE -FABRICATED ITEMS TO BE HANDLED AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ----------------------------------------------------------- I I I I Ir------------------------------------------------------� I I I (E) FURRING I I I I WALL I I I I I I I I I I I I I I I I I I I I (E) WALL I I I I I I I I I I I I I I I I I (E) CMU WALL (E) POST NP. EXTERIOR 15 15 I I I I s-2 s-2 I I I 1 I 1 I „1 I I �_—� — 30"� � _ 30� I I I I ` �ro I I��(E) FTG. I I eP�J evzv I I I I I I I I I I I I I I (E) SLAB —ON —GRADE I I I I TO REMAIN I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I --------------J I I I L------------------------------------------------------------J I a op-im 'I �VA wn � � �l FOOTING SCHEDULE: QING HUA HUANG ,!�inghuahng @yahoo.com (20G) 37 1 -2770 MUA 76 7 IsR� TONAL 0 N 0 00 Q cf 0 z 0 o w w Ow r� ~ V cf) z_ Q O � Ln a DATE: 5/22/2021 SHEET TITLE: ROOF FRAMING PLAN FOUNDATION PLAN AND NOTES ............................................... REVIEWED BY CITY OF EDMONDS .'.1.1.'. BUILDING DEPARTMENT.... RESUB May 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISIONS: PERMIT SUBMITTAL BLD2021-0271 SHEET NUMBER: SCALE: 1 /4" = 1'-0" I 1 30" x 30" x 12" FOOTING w/ I 1 (4) #4 EACH WAY, BOTTOM L — 30"1 MAKE-UP AIR UNIT (668 lbs) SEE MECHANICAL DRAWINGS FOR FINAL LOCATION %4"x4%2"SDS SCREWS @ 12" 0. C., MIN. (4)-SCREW5 AT EACH SIDE OF CURB TO WOOD FRAMING BELOW (E)-DEC SECTION Rfl SECURE MAKE-UP AIR UNIT TO METAL CURB w/ SCREWS @ 12" 0. C., MIN. (5)-SCREW5 EA. SIDE - -11 FM + + + + U. Or#10 + + + + + 4-#10 S, SIDE FR BASE T( 16 GA. ) BY OTH, (E) WOOD LEDGER ADD (5)-16d NAILS TO STUD WHERE NEW BEAM OCCURS 10' MIN. TO ANY AIR INTAKE AND PROPERTY LINE IN ANY DIRECTION; 10' MIN. FROM SAME OR ADJACENT BUILDING EXHAUST FAN ROOF ATTACHMENT 10' MIN. FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE METAL CURB BY OTHERS WATERPROOFING BY OTHERS 'ILING JOIST tx12 BLOCKING -EN (E)-CEILING jun ► S WHERE METAL CURB OCCURS w/ (2)-A35 EA. END WATERPROOFING BY OTHERS (E)-BEAM MAKE -UP -AIR UNIT ROOF ATTACHMENT N. T. S. %4'k3%2" SIMPSON SCREWS AT EACH OF CURB TO MING BELOW TERPROOFI NG OTHERS DECKING � IN - (E)-BEAM (E)-CEILING JOIST N. T. S. SECTION NOTE: FOR HOOD CONNECTION SEE 10/S-2 %4'X4%2" SDS SCREWS @ 12" 0. C., MIN. (4)-SCREWS AT EACH SIDE OF CURB TO WOOD FRAMING BELOW (E)-DECKING T/ROOF (E)-ROOF BEAM (E) DECKING Et CEILING JOISTS NOT SHOWN FOR CLARITY (E) BEAM POST PER PLAN (E) BEAM TO (N) POST CONNECTION (E) CEILING JOISTS NOT SHOWN FOR CLARITY — DTT2Z w/ (8)-%4'k1 %2" SDS SCREWS, TYP. LOCATE DTT2Z AT THE UPPER HALF OF THE BEAM I %" UNI-STRUT (P1000) BETWEEN HOOD HANGING BRACKETS (2)-LOCATIONS N. T. S. NOTE: FOR INFORN SHOWN SEE (N) 4x 12 B PER PLAN (E)-DECKIP SHORE -UP CEILING JI FOR NEW I INSTALLAI EXHAUST FAN ROOF ATTACHMENT 1 %" UNI-STRUT (P1000) SECURE TO (E) CEILING JOISTS w/ %4 "x2" SDS SCREWS (E)-DECKING T/ROOF (E)-BEAM (E) WOOD LEDGER (E) 2x8 3/8 "0 A36 (Fy = 36 ksi) THREADED ROD w/ LOCK NUTS at TOP Ct BOTTOM HANGERMATE TYP. AT SUPPLY PLENUM EZG670 ANCHORS 1 %" UNI-STRUT (P1000) %2 "0 A36 (Fy = 36 ksi) BETWEEN HOOD THREADED ROD w/ LOCK HANGING BRACKETS NUTS at TOP Et BOTTOM TYP. AT KITCHEN HOOD HOOD HANGING BRACKET, TYP. (E) CMU WALL (E) WOOD FURRING WALL MINA N1.11fIr1pil SUPPLY PLENUM KITCHEN HOOD 6" LONG SCREWS TO EACH STUD INSULATION BY OTHERS KITCHEN HOOD ATTACHMENT (E)-DECKING T/ROOF (E)-CEILING JOIST (E)-BEAM %2 "0 GRADE 36 (Fy = 36 ksi) THREADED ROD w/ LOCK NUTS at TOP Et BOTTOM, TYP. HOOD HANGING BRACKET KITCHEN HOOD TO (E) BEAM CONNECTION N. T. S. — 5/8 "0 EXPANSION ANCHOR 5" MIN. EMBED -------- #4 DOWELS @ 18" 0. C. E. W., DRILL Et EPDXY (E) SLAB - ON -GRADE FOOTING TO BEAR DIRECTLY ON SUITABLE BEARING SOILS N. T. S. 0 0 1 '-0" MIN. LAP N WIDTH PER SCHEDULE (N) 4x12 BEAM PER PLAN (E)-DECKING (E) CEILING JOISTS w/ LUS28 HANGER TYP. -SHORE-UP (E) CEILING JOISTS FOR NEW BEAM INSTALLATION N. T. S. POST PER PLAN w/ ABU46Z POST BASE FOOTING REINFORCING PER SCHEDULE 4" TYP. N� Lu a SPREAD FOOTING AT (E) SLAB -ON -GRADE N. T. S. QING HUA HUANG ginghuahng@yahoo.com (20(S) 371 -2770 vW A 1 Fe 7 f �NAL O N O 00 O Q U) 0 z O 0 E4 W 44 ~ W OW z_ P O � LO to DATE: 5/22/2021 SHEET TITLE: -- DETAILS RESUB May 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISIONS: PERMIT REVISIONS BLD2021-0271 SHEET NUMBER: S�2