Loading...
APPROVED PLN BLD RESUB1 BLD2021-0441 ARCHITECTUAL PLANSI Exi s.n"6 Nt AWO 4 RIFIR r,-IJE- V EflmoNDs, Wh 9B°7-6 00G, Q 10000 $505 APPROVED BY PLANNING May 12 2021 APPROVED BY CITY OF EDMONDS BUILDING DIVISION Apr 29 2021 City Of Edmonds Building Department Work DECK REPAIR & EXPANSION Address 7110 164TH ST SW Owner ENEV Approved Date 4/29/2021 Building Official V07LOWMUL W. W vgiiiz c Permit Number BLD2021-0441 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE RESUB Apr 22 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Alt I t-�—a �2 1 11ED�Ell rqr�,,� Sy�''-o lj5t ST?m IZ- rAlgo 4 AFl� �NIV 7)1c) 16LIT0StSO EDMWD �, Wh g80Z(a 005 11) 000 013E a 9 • S Paten N)ELKIP fi No kyetviw� -c"emcks RESUB Apr 22 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT k f-N IGUARDRAILS SHALL BE DESIGNED TO RESIST A • CONCENTRATED LOAD OF 200 POUNDS IN ANY DIRECTION AT I ■ THE TOP OF THE GUARDRAIL. INFILL COMPONENTS SHALL BE ■ I DESIGNED TO RESIST A HORIZONTAL LOAD OF 50 POUNDS I ■ OVER A ONE SQUARE FOOT AREA. (GUARDRAILS SHALL BE MIN. 36" IN HEIGHT WHERE THE ADJACENT SURFACE OR GRADE IS 30" OR MORE BELOW. ■ ' RAILINGS SHALL BE SPACED TO NOT ALLOW THE I ' PASSAGE OF A 4" SPHERE. ■■■■■■■■■■■■1 IHANDRAILS ARE REQUIRED AT STAIRS WITH FOUR OR MORE ' RISERS. ALL HANDRAILS TO BE LOCATED 34" TO 38" ABOVE TREAD I • NOSING. OPEN SIDES OF STAIRS MORE THEN 30" ABOVE ADJACENT ■ I FLOOR SHALL HAVE HANDRAILS & GUARDRAILS. THE HANDGRIP . PORTION SHALL HAVE A CROSS SECTIONAL DIMENSION OF 1 %" TO �,ry) ' (R.o FiA E- 4v �i�� IbNiH STSLj EJ7m avDs, wh '13oZ to cx�Si3l00co 8so9 RTAIR RICFRC CH I I RP: 7 3/." HAY TREAD DEPTH ■ TREAD DEPTH I OPEN RISERS L NOT ALLOW I iERE. 1 ■ ■ ■■■r (SDI I SAFETY GLASS REQUIRED IN ■ HAZARDOUS LOCATIONS RESUB Apr 22 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �D% 2". 0 mlGUARDRAILS SHALL BE MIN. 36" IN HEIGHT WHERE THE (ADJACENT SURFACE OR GRADE IS 30" OR MORE BELOW. ■ ■ RAILINGS SHALL BE SPACED TO NOT ALLOW THE PASSAGE OF A 4" SPHERE. SAFETY GLASS REQUIRED IN ■ HAZARDOUS LOCATIONS Soot i- s lioe- (GUARDRAILS SHALL BE DESIGNED TO RESIST A ■ CONCENTRATED LOAD OF 200 POUNDS IN ANY DIRECTION AT ■ THE TOP OF THE GUARDRAIL. INFILL COMPONENTS SHALL BE ■ I DESIGNED TO RESIST A HORIZONTAL LOAD OF 50 POUNDS ■ OVER A ONE SQUARE FOOT AREA. MF 9.0 r AF FA- �- � V 111c). 1� g ly sr.5�v �a t �F'Fls+y'��e.^�.���r•irno�a r. d++�•-n.• -yr .Yr...� • •- ...r' qx b Q PD I RESUB Apr222021 HANDRAILS ARE REQUIRED AT STAIRS WITH FOUR OR MORE CITY E DEVELOPMENT SERVICES SERVICES I RISERS. ALL HANDRAILS TO BE LOCATED 34" TO 38" ABOVE TREAD DEPARTMENT ■ NOSING. OPEN SIDES OF STAIRS MORE THEN 30" ABOVE ADJACENT ■ FLOOR SHALL HAVE HANDRAILS & GUARDRAILS. THE HANDGRIP . PORTION SHALL HAVE A CROSS SECTIONAL DIMENSION OF 1'/4" TO L2 . WA q�w STAIR RISERS SHALL BE 7 %" MAX. TREAD DEPTH ■ ■ SHALL BE 10" MIN. RISER HEIGHT AND TREAD DEPTH MUST NOT VARY BY MORE THAN 3/8". OPEN RISERS ■ MORE THAN 30" ABOVE GRADE SHALL NOT ALLOW ■ THE PASSAGE OF A 4" DIAMETER SPHERE. L. . . . . . . 0 0 1