APPROVED BLD BLD2021-0769+Plumbing_Plan+6.7.2021_6.10.14_AM+2234343GENERAL NOTES
1. REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE WORK
COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL, CIVIL, ELECTRICAL,
LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC
MANUFACTURER'S DIMENSIONS (VERIFY).
2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR
ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC. OF MECHANICAL
EQUIPMENT, UNLESS OTHERWISE INDICATED.
3. CODES: COMPLETE INSTALLATION OF THE PLUMBING SYSTEM SHALL BE
PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY, PLUMBING, FIRE,
AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL
AHJ.
4. PLUMBING CONTRACTOR SHALL LOCATE AND COORDINATE EXACT
LOCATION OF ALL PLUMBING EQUIPMENT WITHIN THE STRUCTURE.
5. ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL
ACCESS DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF
CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE
FIRE RATED. VERIFY ACCESS DOOR LOCATIONS WITH GENERAL
CONTRACTOR PRIOR TO BIDDING.
6. EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED PIPING IN
FINISHED ROOMS.
7. PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING
PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK
PENETRATIONS.
8. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY
PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS
CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL
WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES
FOR SERVICE AND MAINTENANCE.
COORDINATION REQUIREMENTS
1. PLUMBING FIXTURES & EQUIPMENT: COORDINATE EXACT LOCATION OF
ALL PLUMBING FIXTURES & EQUIPMENT WITH ARCHITECTURAL AND
OTHER TRADES DOCUMENTS.
2. PIPING: COORDINATE EXACT LOCATION OF ALL STRUCTURAL FRAMING &
FOOTINGS AND FINALIZE THE EXACT ROUTING OF ALL PIPES WITH
STRUCTURAL ENGINEER AT THE SITE PRIOR TO AND DURING THE
CONSTRUCTION. COORDINATE UNDER GRADE PIPING & FOUNDATION
DRAINAGE PIPING WITH CIVIL ENGINEER.
3. ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS, IGNITION
DEVICES, DRIVES, ETC. SHALL BE ADJUSTED AND BALANCED TO
OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE
AND ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL.
4. APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE
APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL
HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY,
POLLUTION, ENVIRONMENTAL, SEISMIC, APPLICABLE CODES AND
REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH
MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED
TO MEET THE BID DOCUMENTS.
5. PRIOR TO PIPING INSTALLATION: PLUMBING CONTRACTOR TO
COORDINATE PIPING LAYOUT WITH ALL OTHER TRADES.
6. ACCESS: COORDINATE ALL ACCESS LOCATIONS WITH GENERAL
CONTRACTOR AND ARCHITECT TO ENSURE ALL REQUIRED ACCESS
HATCHES, ACCESS PANELS & ACCESS COVERS ARE PROVIDED.
7. ANY DISCREPANCIES SHOULD BE REPORTED TO THE ARCHITECT
IMMEDIATELY.
SYMBOLS
GENERAL
ARCHITECTURAL BACKGROUND
(THIN LINE)
NEW PIPING (HEAVY LINE)
EXISTING PIPING (THIN LINE)
EXISTING WORK TO BE REMOVED
MATCHLINE OR PROPERTY LINE
CONNECTION TO EXISTING
SECTION IDENTIFICATION
INDICATES DIRECTION OF CUTTING
PLANE
LETTER INDICATES SECTION
A (NO. INDICATES DETAIL)
P-3 P-3 SHEET NUMBER WHERE SECTION IS
DRAWN
SHEET NUMBER WHERE SECTION IS
TAKEN
DETAIL IDENTIFICATION
# DETAIL NUMBER
DRAWING/SHEET NUMBER
EQUIPMENT
TYPICAL EQUIPMENT DESIGNATION
HWCP-1
MN
W
WASTE BELOW GRADE
W
WASTE ABOVE GRADE
PW
PUMPED WASTE
IW
INDIRECT WASTE
SS
SANITARY SEWER BELOW GRADE
SS
SANITARY SEWER ABOVE GRADE
PSS
PUMPED SANITARY SEWER
V
VENT
SD
STORM DRAIN
OD
OVERFLOW STORM DRAIN
PSD
PUMPED STORM DRAIN
CD
CONDENSATE DRAIN
PCD
PUMPED CONDENSATE DRAIN
-
COLD WATER (CW)
- -
HOT WATER (HW), POTABLE, 120`F
- - 140
HOT WATER, POTABLE,
TEMPERATURE OTHER THAN 120°F
- - -
HOT WATER CIRCULATING (HWC),
POTABLE, 120°F
— - - - 140
HOT WATER CIRCULATING, POTABLE,
TEMPERATURE OTHER THAN 120°F
FOF
FUEL OIL FILL
FOS
FUEL OIL SUPPLY
FOR
FUEL OIL RETURN
— — FOV —
FUEL OIL VENT
RV
RELIEF VENT
G
LOW PRESSURE NATURAL GAS
MPG
MEDIUM PRESSURE NATURAL GAS
IRR
IRRIGATION (NON POTABLE)
F
FIRE MAIN
PIPE SYMBOLS
Mi,
TOP PIPE CONNECTION
BOTTOM PIPE CONNECTION
Y
PIPE TURNING UP
D
PIPE TURNING DOWN/DROP
PIPE CAP
PIPE PLUG
UNION
FLANGE
WYE STRAINER
WYE STRAINER WITH CAPPED HOSE
END BLOWDOWN VALVE
ABBREVIATIONS
ABV
ABOVE
FLR
AD
AREA DRAIN
FPM
BALL VALVE
AFF
ABOVE FINISHED FLOOR
FPS
AHJ
AUTHORITY HAVING JURISDICTION
FS
BFF
BELOW FINISHED FLOOR
FT
BALL VALVE
BFP
BACKFLOW PREVENTER
FU
BOH
BACK OF HOUSE
G
GLOBE VALVE
BP
BOOSTER PUMP
GAL
BT
BATHTUB
GD
CHECK VALVE
BTUH
BRITISH THERMAL UNIT PER
GM
HOUR
GPG
BALANCING OR PLUG VALVE
BV
BALANCING VALVE
GPM
C
COMMON
GV
BUTTERFLY VALVE
CAP
CAPACITY
GWB
CB
CATCH BASIN
GWH
CD
CONDENSATE DRAIN
HB
FLEXIBLE CONNECTION IN PIPING
CFF
CAPPED FOR FUTURE
HD
CFM
CUBIC FEET PER MINUTE
HDR
CI
CAST IRON
HEDV
aa
PRESSURE REDUCING VALVE (PRV)
CLG
CLW
CEILING, COOLING
CLOTHES WASHER
HORIZ
HP
PRV
CO
CLEANOUTS
HPCW
Q
COMB
COMBUSTION
HW
AUTOMATIC CONTROL VALVE, 2-WAY
CONT
CONTINUE, CONTROL
HWC
CONTR
CONTRACTOR
HWCP
AUTOMATIC CONTROL VALVE, 3-WAY
COTG
CLEANOUTS TO GRADE
HWR
CP
CIRCULATING PUMP
HWST
CV
CHECK VALVE
HX
ID
RELIEF VALVE
CW
COLD WATER
ICW
D
DIAMETER
ID
DB
DRY BULB, DECIBEL
IE
BALANCING/METERING VALVE
DF
DRINKING FOUNTAIN
IHW
DFU
DRAIN FIXTURE UNITS
IN
BV
DI
DUCTILE IRON
KS
REDUCER
DIM
DIMENSION
KW
DN
DOWN
L
DIRECTION OF FLOW
DS
DOWN SPOUT
LAV
DWG
DRAWING
LB
A
PIPE ANCHOR
(E)
EXISTING
M
EFF
EFFICIENCY
MBH
PIPE ALIGNMENT GUIDE
ELEC
ELECTRIC
MECH
EQUIV
EQUIVALENT
MCA
PIPE SUPPORT
EWC
ELECTRIC WATER COOLER
MOCP
i PS
EWH
ELECTRIC WATER HEATER
MPG
-D0c
VALVE STATION OR ASSEMBLY
EXT
EXTERIOR, EXTERNAL
MTD
F
FAHRENHEIT
(N)
FCO
FLOOR CLEANOUTS
NC
INDIRECT DRAIN, PIPE TO DRAIN
FD
FLOOR DRAIN
NO
ID
FDC
FIRE DEPARTMENT CONNECTION
OD
POINT OF CONNECTION
FF
FINISHED FLOOR
O
RD OD
ROOF DRAIN, OVERFLOW DRAIN
FLOOR
OPD
FEET PER MINUTE
OPNG
FEET PER SECOND
P
FLOOR SINK
PD
FEET
POC
FIXTURE UNITS
PRV
GAS (LOW PRESSURE)
GALLONS
PS
GARAGE DRAIN
PSIG
GAS METER
GRAINS PER GALLON
PSD
GALLONS PER MINUTE
PSS
GATE VALVE
PSW
GYPSUM WALLBOARD
PW
GAS WATER HEATER
RD
HOSE BIBB
REF
HEAD
RPBP
HUB DRAIN
HOSE END DRAIN VALVE
RPM
HORIZONTAL
S
HORSEPOWER
SCH
HIGH PRESSURE COLD WATER
SCW
HOT WATER
SD
HOT WATER RE -CIRCULATION
SEP
HOT WATER CIRCULATION PUMP
SF
HOT WATER RETURN
SGSV
HOT WATER STORAGE TANK
SH
HEAT EXCHANGER
SO
INDUSTRIAL COLD WATER
SIP
INDIRECT DRAIN, INSIDE DIAMETER
SR
INVERT ELEVATION
SS
INDUSTRIAL HOT WATER
INCH
SSS
KITCHEN SINK
STD
KILOWATT
SQ
LONG, LENGTH
TD
LAVATORY
TMV
POUND
TIP
WATER METER
TYP
THOUSAND BTU PER HOUR
UH
MECHANICAL
UON
MIN. CIRCUIT AMPACITY
UR
MAX. OVER CURRENT PROTECTION
V
MEDIUM PRESSURE GAS
VTR
MOUNTED
W
NEW
WC
NORMALLY CLOSED
WCO
NORMALLY OPEN
WHD
OUTSIDE DIMENSION/DIAMETER WM
OVERFLOW DRAIN/DECK DRAIN WSFU
OVER PRESSURE DEVICE
OPENING
PUMP
PRESSURE DROP, PLANTER DRAIN
POINT OF CONNECTION
PRESSURE REDUCING VALVE
PRESSURE RELIEF VALVE
PUMPED STORM DRAINAGE
POUNDS PER SQUARE INCH
GAUGE
PUMPED STORM DRAINAGE
PUMPED SANITARY SEWER
PUMPED SANITARY WASTE
PUMPED WASTE
ROOF DRAIN
REFERENCE
REDUCED PRESSURE BACKFLOW
PREVENTER
REVOLUTIONS PER MINUTE
SINK
SCHEDULE
SOFTENED COLD WATER
STORM DRAIN
SEWAGE EJECTOR PUMP
SQUARE FOOT
SEISMIC GAS SHUT-OFF VALVE
SHOWER
STORM OVERFLOW
STATIC PRESSURE/SUMP PUMP
SUDS RELIEF
STAINLESS STEEL/SANITARY
SEWER
SIDE SANITARY SEWER
STANDARD
SQUARE
TRENCH DRAIN
THERMOSTATIC MIXING VALVE
TRAP PRIMER
TYPICAL
UNIT HEATER
UNLESS OTHERWISE NOTED
URINAL
VENT
VENT THRU ROOF
WASTE, WATT, WIDE
WATER CLOSET
WALL CLEANOUTS
WALL HYDRANT
WASHING MACHINE
WATER SUPPLY FIXTURE UNITS
® ❑o
FLOOR DRAIN
DRAWING INDEX
�
HOSE BIBB
DWG
DESCRIPTION
INCLUDED IN S E T
BREAK IN PIPING OR DUCTWORK
M
GAS METER
� N
U) N
M
INLINE WATER METER
LJ
g �
> Ln
p� Ln
PUMP
wi o
o
LdLd
T
PRESSURE GAUGE
P-0.0
LEGEND, GENERAL
NOTES, AND DRAWING INDEX
x
P-0.1
PLUMBING NOTES,
TABLES, AND CODES
x
THERMOMETER
P/T
t
PRESSURE/TEMPERATURE
P-1.0
FLOOR PLANS - FIRST & SECOND FLOOR
x
TEST PORT
P-1.1
FLOOR PLAN - THIRD FLOOR
x
�4�I,,-,D*—
REDUCED PRESSURE BACKFLOW
P-2.0
ENLARGED PLAN -
FIRST FLOOR
x
RPBP
PREVENTER
P-2.1
ENLARGED PLAN -
SECOND FLOOR
x
P-2.2
ENLARGED PLAN -
THIRD FLOOR
x
DOUBLE CHECK VALVE ASSEMBLY
DCVA
CATCH BASIN - SAND/OIL INTERCEPTOR
TRENCH DRAIN
I I I I I I I I I III III III I I
i
EMERGENCY GAS SHUT-OFF VALVE
ITS— SEISMIC GAS SHUT-OFF VALVE
F-1 WASHER BOX
--a-GREASE INTERCEPTOR
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
r-----------------------------------------------------------
Fire Rated Penetrations shall be
maintained
-----------------------------------------------------------
City Of Edmonds
Building Department
Work PLUMBING
Address 750 EDMONDS WAY
Owner SUNRISE SENIOR LIVING
Approved Date 6-16-2021
Building Official Erica Cu-r(-er
Permit Number BLD2021-0769
RECEIVED
Jun 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
z
0
0
w
U)
w
0
LLw
0
0
z
❑❑❑p0'0
00 ROeO000
❑
a
0�0 �FGISTERF'.-• �000
O
oO000 /ONAL
05
nOBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
206-364-3343 TEL
CONTACT: JON ROBISON
J
J
Of
W
Ld
(n
c�
c�
a_
a_
LLJ
LLJ
z
z
0
¢
w
cc
LLJ
=
0
0
¢
9
(I
Q
CO
o
Z Z
O o
L �
�ZW
W W >:
LLj�
00OD
WIZ
cA_o
crzo
ZQW
00Hp-.
w
0
DATE:
05/21 /2021
N
0
m
w
C9 m
C��
o m
� cm
0 o
O
O O cv
LJ
ozz
rn —1 0--
z
O
C&
(j) z
Mw
W
0z
0
z
SHEET TITLE:
LEGEND, GENERAL
NOTES, AND
DRAWING INDEX
SHEET NO.
POOO
PLUMBING TABLES
PIPE INSULATION SCHEDULE
OPTION 1
OPTION 2
SERVICE
VAPOR RETARDER
NOTES
REQUIRED
MATERIAL
THICKNESS
MATERIAL
THICKNESS
DOMESTIC COLD WATER, IRRIGATION WATER, CONDENSATE
MINERAL -FIBER WITH JACKET
ALL SIZES: Y2"
PVC/NBR
ALL SIZES: 3/g"
YES
12,13
DRAINS, STORM DRAIN (IN CONDITIONED SPACE)
(PIPE)
(
DOMESTIC COLD WATER, IRRIGATION WATER, CONDENSATE
MINERAL -FIBER WITH JACKET
Y2" Y2"
PVC/NBR
)
Y2" PIPEY2"
YES
7,8,10
DRAINS, WASTE (OUTSIDE THE CONDITIONED SPACE)
ALL OTHER SIZES: 1"
ALL OTHER SIZES: 3/4"
DOMESTIC HOT WATER AND RECIRCULATED HOT WATER
MINERAL -FIBER WITH JACKET
%2"-1%4" PIPE: 1"
PVC/NBR
%2"-1%4" PIPE: 1"
NO
3,9
(NONRESIDENTIAL)
1Y2"-4" PIPE:1.5"
1Y2"-4" PIPE:1.5"
EXPOSED SANITARY DRAINS AND DOMESTIC WATER SUPPLIES
TRUEBRO LAV-GUARD
N/A
N/A
N/A
NO
11
AND STOPS FOR ADA FIXTURES.
NOTES:
1. PIPING INSULATION EXPOSED TO THE WEATHER SHALL BE PROTECTED FROM DAMAGE. CONTRACTOR SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. ADHESIVE
TAPE SHALL NOT BE PERMITTED.
2. PER 2018 WSEC SECTION R403.5.3 (RESIDENTIAL) INSULATION FOR HOT WATER PIPE SHALL HAVE A MINIMUM R-VALUE OF R-3.
3. PIPING FROM WATER HEATER TO THE TERMINATION OF HEATED WATER SUPPLY PIPE SHALL BE INSULATED IN ACCORDANCE WITH TABLE C403.2.9.
4. ON BOTH THE INLET AND OUTLET PIPING OF A STORAGE HOT WATER HEATER, THE FIRST 8 FEET OF PIPING OR PIPING FROM WATER HEATER TO HEAT TRAP SHALL BE INSULATED.
5. HEAT TRACED PIPING SHALL BE INSULATED IN THE SAME MANNER AS NON HEAT TRACED PIPING OR PER THE HEAT TRACE MANUFACTURER'S INSTRUCTIONS.
6. TUBULAR PIPING INSULATION SHALL NOT BE REQUIRED FOR THE FOLLOWING:
6.1. THE TUBING FROM THE CONNECTION AT THE TERMINATION OF THE FIXTURE SUPPLY PIPING TO A PLUMBING FIXTURE OR PLUMBING APPLIANCE.
6.2. VALVES, PUMPS, STRAINERS, AND THREADED UNIONS IN PIPING THAT IS 1 INCH OR LESS IN NOMINAL DIAMETER.
6.3. PIPING FROM USER -CONTROLLED SHOWER AND BATH MIXING VALVES TO THE WATER OUTLETS.
6.4. COLD WATER PIPING OF A DEMAND RECIRCULATION WATER SYSTEM.
6.5. TUBING FROM A HOT DRINKING -WATER HEATING UNIT TO THE WATER OUTLET.
6.6. PIPING AT LOCATIONS WHERE A VERTICAL SUPPORT OF THE PIPING IS INSTALLED.
6.7. PIPING SURROUNDED BY BUILDING INSULATION WITH A THERMAL RESISTANCE (R-VALUE) OF NOT LESS THAN R-3.
6.8. HOT WATER PIPING THAT IS PART OF THE FINAL PIPE RUN TO THE PLUMBING FIXTURE AND IS NOT PART OF THE HEATED -WATER CIRCULATION SYSTEM CIRCULATION PATH IS NOT REQUIRED TO MEET THE
MINIMUM INSULATION REQUIREMENTS OF C404.6.
7. PER 2018 UPC SECTION 312.6 NO WATER, SOIL, OR WASTE PIPE SHALL BE INSTALLED OR PERMITTED OUTSIDE OF A BUILDING, IN ATTICS OR CRAWL SPACES, OR IN AN EXTERIOR WALL UNLESS, WHERE NECESSARY,
ADEQUATE PROVISION IS MADE TO PROTECT SUCH PIPE FROM FREEZING. ALL HOT AND COLD WATER PIPES OUTSIDE THE CONDITIONED SPACE SHALL BE PROVIDED WITH INSULATION WITH A MINIMUM R-VALUE OF
R-3.
8. HEAT TRACING SHALL BE PROVIDED FOR COLD WATER AND IRRIGATION WATER IN UNCONDITIONED SPACES. CONTACT ENGINEERING IF NECESSARY. PER 2018 WSEC SECTION C403.12.3 FREEZE PROTECTION SYSTEMS,
SUCH AS HEAT TRACING OF OUTDOOR PIPING, SHALL INCLUDE AUTOMATIC CONTROLS CONFIGURED TO SHUT OFF THE SYSTEMS WHEN OUTDOOR AIR TEMPERATURES ARE ABOVE 407.
9. PER 2018 WSEC TABLE C403.2.9 INSULATION FOR HOT WATER AND HOT WATER RECIRCULATION SHALL HAVE A THERMAL CONDUCTIVITY OF 0.21-0.28 (BTU.IN/H.FT2.°F) AT OPERATING TEMPERATURE.
10. INSULATION R-VALUE SHALL MEET THE MINIMUM REQUIREMENT. THICKNESS IS BASED ON GRAINGER SAMPLE DATA FOR K-FLEX(PVC/NBR) AND OWENS CORNING(FIBER GLASS).
11. ALL ADA P-TRAPS, HOT WATER SUPPLY TUBING, AND SHUT-OFF COCKS SHALL BE PROTECTED WITH APPROVED COVERS TO PREVENT SCALDING.
12. REQUIRED BY ENGINEERING BASED ON BEST PRACTICE.
13. INSULATION IS NOT REQUIRED ON PLASTIC COLD WATER PIPING.
PIPING SUPPORTS (SUPPLY)
IALL SUSPENDED WATER SUPPLY PIPE SHALL BE I
SUPPORTED AS FOLLOWS PER 2018 UPC TABLE 313.3:
MAX. HORIZONTAL
SPACING
MAX. VERTICAL
SPACING
COPPER PIPE <1Y2"
6 FT.
10 FT.
COPPER PIPE >2"
10 FT.
10 FT.
COPPER TUBING <1Y2"
6 FT.
10 FT.
COPPER TUBING >2"
10 FT.
10 FT.
CPVC < 1 "
3 FT.
10 FT.
CPVC > 1Y4"
4 FT.
10 FT.
HANGER SPACING FOR WASTE AND VENT PIPING
IALL SUSPENDED SANITARY AND VENT PIPE SHALL BE I
SUPPORTED AS FOLLOWS PER 2018 UPC TABLE 313.3:
MAX. HORIZ.
SPACING
MAX. VERT.
SPACING
ABS
4 FT.
10 FT.
PVC (TYPE DWV)
4 FT.
10 FT.
CAST-IRON HUBLESS*
EVERY
OTHER JOINT
15 FT.
*CAST-IRON OVER 4' SHALL BE SUPPORTED AT EVERY JOINT
PLUMBING FIXTURE FLOW RATES PER 2018 UPC CH. 4
FIXTURE TYPE
FLOW RATE
MAXIMUM FLOW RATE AT ?
20 PERCENT REDUCTION
NOTES
SHOWERHEADS
2.5 GPM @ 80 PSI
2 GPM @ 80 PSI
LAVATORY FAUCETS, RESIDENTIAL
2.2 GPM @ 60 PSI
1.5 GPM ® 60 PSI
1
LAVATORY FAUCETS, NON-RESIDENTIAL
0.5 GPM @ 60 PSI
0.4 GPM ® 60 PSI
2
KITCHEN FAUCETS
2.2 GPM @ 60 PSI
1.8 GPM ® 60 PSI
3
GRAVITY TANK -TYPE WATER CLOSETS
1.6 GALLONS/FLUSH
1.28 GALLONS/FLUSH
4
FLUSHOMETER TANK WATER CLOSETS
1.6 GALLONS/FLUSH
1.28 GALLONS/FLUSH
4
FLUSHOMETER VALVE WATER CLOSETS
1.6 GALLONS/FLUSH
1.28 GALLONS/FLUSH
4
ELECTROMECHANICAL HYDRAULIC WATER CLOSETS
1.6 GALLONS/FLUSH
1.28 GALLONS/FLUSH
4
URINALS
1.0 GALLONS/FLUSH
0.5 GALLONS/ FLUSH
NOTES:
1 • LAVATORY FAUCETS SHALL NOT HAVE A FLOW RATE LESS THAN 0.8 GPM AT 20 PSI.
2• WHERE COMPLYING FAUCETS ARE UNAVAILABLE, AERATORS RATED AT 0.35 GPM OR OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION.
3. KITCHEN FAUCETS MAY TEMPORARILY INCREASE FLOW ABOVE THE MAXIMUM RATE, BUT NOT ABOVE 2.2 GPM @ 60 PSI AND MUST DEFAULT
TO A MAXIMUM FLOW RATE OF 1.8 GPM @ 60 PSI.
4. INCLUDES SINGLE AND DUAL FLUSH WATER CLOSETS WITH AN EFFECTIVE FLUSH OF 1.6 GALLONS OR LESS. SINGLE FLUSH TOILETS - THE
EFFECTIVE FLUSH VOLUME SHALL NOT EXCEED 1.6 GALLONS. THE EFFECTIVE FLUSH VOLUME IS THE AVERAGE FLUSH VOLUME WHEN TESTED
IN ACCORDANCE WITH ASME A112.19.2 DUAL FLUSH TOILETS - THE EFFECTIVE FLUSH VOLUME SHALL NOT EXCEED 1.6 GALLONS. THE
EFFECTIVE FLUSH VOLUME IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH.
FLUSH VOLUMES WILL BE TESTED IN ACCORDANCE WITH ASME A112.19.2 AND ASME A112.19.14.
NOTE TO CONTRACTOR
DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE,
LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED
FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR
DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS
FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE
DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS
NECESSARY FOR A COMPLETE SYSTEM.
CONTRACTOR SUBSTITUTIONS
8 REVISIONS
PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS FOR REVIEW AND APPROVAL
PRIOR TO ORDERING MATERIAL OR DOING WORK. FOR EQUIPMENT THAT IS SCHEDULED BY
MANUFACTURER'S NAME AND CATALOG DESIGNATIONS, THE MANUFACTURER'S PUBLISHED DATA
AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION.
ENGINEERING COSTS FOR REVISING MEP PLANS SHALL BE ADDRESSED IN THE COST ANALYSIS
OF THE SUBSTITUTION PROPOSAL. CONTRACTOR TO COORDINATE WITH ENGINEER AND
DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS. CONTRACTOR SHALL BE RESPONSIBLE
FOR OTHER COSTS ASSOCIATED WITH UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS
OR REVISIONS.
PIPE MATERIALS
APPROVED PLUMBING MATERIAL:
ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING
AGENCY.
1. ABOVEGROUND WATER DISTRIBUTION PIPING: COPPER, TYPE L OR PEX.
2. UNDERGROUND WASTE & VENT PIPING: NO HUB CAST IRON, ABS SCHEDULE 40
NOTE 1: EXTERIOR INSTALLATIONS OF ABS AND PVC PIPING FOR CONDENSATE
DRAINAGE AND ABOVE GROUND VENTING SHALL BE PROTECTED FROM DIRECT
EXPOSURE TO SUNLIGHT PER 2016 CPC 312.13 AND 312.14
3. ABOVE GROUND WASTE & VENT PIPING: NO HUB CAST IRON, ABS SCHEDULE 40.
4. CONDENSATE DRAIN PIPING: CPVC OR COPPER TYPE M.
5. TEMPERATURE AND/OR PRESSURE RELIEF VALVE DISCHARGE PIPING: COPPER
TYPE M
6. GAS PIPING: STEEL PIPE, ASTM A 53; TYPE E OR S; GRADE B; SCHEDULE 40.
PLUMBING NOTES
CONNECTIONS: PROVIDE PLUMBING FIXTURE CONNECTIONS TO BUILDING 27. INSULATION MATERIAL SHALL MEET CITY OF KIRKLAND QUALITY
WASTE, VENT, COLD WATER, AND HOT WATER SYSTEM IN ACCORDANCE STANDARDS.
WITH DRAWINGS, MANUFACTURER'S RECOMMENDATIONS, AND LOCAL
CODES. CONNECT TO EACH FIXTURE, EQUIPMENT, ETC. WITH ALL 28. ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH
ACCESSORIES, VALVES, VACUUM BREAKERS, REGULATORS, UNIONS, THE 2018 WASHINGTON STATE ENERGY CODE.
ETC. AS REQUIRED AND AS RECOMMENDED BY THE MANUFACTURERS.
REFER TO PLUMBING FIXTURE CONNECTION SCHEDULE ON PLANS. 29. BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH
2018 UPC 701.0 AND 903.0.
2.
HOT AND COLD: WATER PIPING CONNECTION TO EACH FIXTURE SHALL
BE COLD WATER ON THE RIGHT HAND SIDE AND HOT WATER ON THE
30.
ALL SANITARY SYSTEM MATERIAL SHALL BE LISTED BY AN APPROVED
LEFT HAND SIDE.
LISTING AGENCY.
3.
HOT WATER: NON -CIRCULATING HOT WATER PIPE SHALL NOT EXCEED
31.
ALL STORAGE WATER HEATING EQUIPMENT SHALL BE PROVIDED WITH
10' UNLESS OTHERWISE SHOWN ON DRAWINGS.
AN APPROVED, LISTED EXPANSION TANK OR OTHER DEVICE DESIGNED
FOR INTERMITTENT OPERATION FOR THERMAL EXPANSION CONTROL PER
4.
VENT STACKS: COORDINATE VENT STACK WITH HVAC EQUIPMENT TO
2018 UPC 608.3.
MAINTAIN MINIMUM 10' CLEARANCE FROM OUTSIDE AIR INTAKES.
32.
WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST
5.
CLEANOUTS: PROVIDE CLEANOUTS PER CURRENT UPC AND AS
HORIZONTAL DISPLACEMENTS DUE TO SEISMIC MOTION PER 2018 UPC
REQUIRED BY LOCAL JURISDICTIONS. CLEANOUTS SHALL BE LOCATED
507.2.
IN WALLS/FLOORS WHERE THEY ARE NOT HIGHLY VISIBLE. FLOOR
CLEANOUTS IN CARPETED AREAS TO BE FITTED WITH CARPET INSERTS.
33.
MATERIAL EXPOSED WITHIN A DUCT OR PLENUM SHALL COMPLY WITH
LOCATIONS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL.
2018 IMC 602.2.1.
NOTE: NOT ALL CLEANOUTS ARE SHOWN ON THE PLUMBING DRAWINGS.
34.
CONTRACTOR SHALL PROVIDE FIRESTOPPING AT PENETRATIONS AS
6.
SHUT -OFFS: PROVIDE 1 /4 TURN BALL VALVE ANGLE STOP SHUT-OFF
NECESSARY TO RETAIN THE FIRE RATING OF ALL ASSEMBLIES. ALL
WORK SHALL BE IN COMPLIANCE WITH CODE REQUIREMENTS FOR THE
VALVES AND BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT
BUILDING CONSTRUCTION TYPE.
AND COLD WATER SUPPLY TO EACH FIXTURE. EXCEPTION: PROVIDE
SCREWDRIVER STOPS AT BATH/SHOWERS.
35.
PLUMBING CONTRACTOR SHALL PROVIDE REDUCED PRESSURE
BACKFLOW PREVENTERS OR OTHER APPROVED BACKFLOW PREVENTION
7.
TRAP ARMS: PROVIDE TRAP ARMS SUCH THAT THE MAXIMUM LENGTH
DEVICE WHERE REQUIRED BY HEALTH AUTHORITIES, FOOD SERVICE
WILL NOT EXCEED CODE REQUIREMENTS.
DRAWINGS, APPLIANCE MANUFACTURER INSTRUCTIONS AND BY CODE.
8. ADA INSULATION: AT PLUMBING PIPING EXPOSED UNDER LAVATORIES,
INSULATE THE EXPOSED PIPING AND TRAPS WITH PRODUCT
SPECIFICALLY DESIGNED FOR THIS APPLICATION MEETING ADA
REQUIREMENTS. PROVIDE HANDI-LAV GUARD OR EQUIVALENT. OFFSET
P-TRAPS TO CLEAR WHEELCHAIR ACCESS.
9. GAS EQUIPMENT: GAS EQUIPMENT SHALL BE INSTALLED PER
EQUIPMENT LISTINGS, APPLICABLE IFGC, UPC, LOCAL CODES & NFPA
STANDARDS.
10. GAS CONNECTIONS: INSTALL FLEXIBLE QUICK DISCONNECT ASSEMBLIES
FOR ALL GAS FIRED KITCHEN EQUIPMENT PER APPLICABLE IFGC, UPC,
LOCAL CODES & NFPA STANDARDS. PROVIDE LOCKABLE GAS
SHUT-OFF VALVES FOR FIREPLACES & BBQS IN UNATTENDED PUBLIC
LOCATIONS IN THE BUILDING.
11. GAS PIPING INSTALLATION: STEEL OR MALLEABLE IRON FUEL LINES 2"
OR SMALLER SHALL BE ASSEMBLED USING THREAD SEALANT SUITABLE
FOR NATURAL GAS. GAS PIPING LARGER THAN 2" SHALL HAVE
WELDED FITTINGS.
12. GAS PIPING ABOVE GROUND: WHERE PASSING THROUGH AN OUTSIDE
WALL, GAS PIPING SHALL BE PROTECTED AGAINST CORROSION BY
COATING OR WRAPPING WITH AN INERT MATERIAL. WHERE PIPING IS
ENCASED IN A PROTECTIVE PIPE SLEEVE, THE ANNULAR SPACE
BETWEEN THE PIPING AND THE SLEEVE SHALL BE SEALED.
13. GAS PIPE SUPPORT: FUEL LINES SHALL BE SUPPORTED OR STRAPPED,
AND SHALL BE PLUMB AND SQUARE.
14. WATER HAMMER ARRESTORS: PROVIDE AT THE END OF HOT AND COLD
WATER LINES SERVING TWO OR MORE FIXTURES; SIZE IN ACCORDANCE
WITH PLUMBING AND DRAINAGE INSTITUTE (PDI) REQUIREMENTS. WATER
HAMMER ARRESTORS ARE REQUIRED FOR QUICK CLOSING VALVES,
SUCH AS LAUNDRY WASHERS, FLUSH VALVES (PUBLIC TOILETS), ETC.
15. TRAP PRIMERS AS SPECIFIED: PROVIDE TRAP PRIMERS AND PIPING
FOR FLOOR DRAINS, FLOOR SINKS, AREA DRAINS & HUB DRAINS.
ARRANGE PIPING TO ACHIEVE EQUAL FLOW TO EACH DRAIN AND
FLOOR SINK FOR TRAP PRIMERS SERVING MULTIPLE DRAINS AND
FLOOR SINKS. COORDINATE EXACT LOCATIONS WITH ARCHITECT &
ELECTRICAL ENGINEER.
16. P-TRAPS: ALL EXPOSED P-TRAPS SHALL BE CHROME -PLATED BRASS.
P-TRAPS SERVING HANDICAPPED COUNTER TOP LAVATORIES SHALL BE
INSULATED.
17. THROUGHOUT THE PROJECT PROVIDE BALL VALVES. GATE VALVES
SHALL NOT BE USED. NO EXCEPTIONS.
18. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING
CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND
OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE.
19. REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO
EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES.
20. OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT.
21. ALL TEMPERATURE MIXING VALVES SHALL COMPLY WITH ASSE-1070
SAFETY STANDARDS.
22. PROVIDE APPROVED PIPE HANGERS & PIPE SUPPORTS IN
ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND
2018 UPC TABLES 313.3 & 313.6. SUBMIT FOR APPROVAL.
23. DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE.
24. PIPING & EQUIPMENT SUPPORTS/HANGERS & SEISMIC RESTRAINTS TO
BE DESIGNED BY DESIGN BUILT CONTRACTOR.
25. IF NEEDED, PROVIDE VACUUM BREAKERS AT ALL HOSE BIBBS.
26. FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE
DRAINAGE AND SUBJECT TO INFREQUENT USE SHALL BE PROVIDED
WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR WATER
SEALS IN ACCORDANCE WITH 2O18 UPC 1007.0.
PROVIDE REQUIRED & PROPER BACK FLOW PREVENTERS AS
SPECIFIED FOR THE APPLIANCES INCLUDING, BUT NOT LIMITED TO THE
FOLLOWING:
a. ICE MACHINES AND ICE MAKERS
b. CARBONATED BEVERAGE DISPENSING SYSTEMS
C. COFFEE BREWERS
d. ESPRESSO MACHINES
e. WATER FILTERS
f. STEAM OR HOT WATER BOILERS
g. IRRIGATION SYSTEM
h. FIRE PROTECTION SYSTEM
I. CHEMICAL TREATMENT SYSTEM
j. SOAP/CHEMICAL DISPENSER SYSTEM
k. COMMERCIAL WASHER
APPLICABLE CODES
THE FOLLOWING PROJECT DESIGN IS BASED ON THE FOLLOWING CODES:
-2018 INTERNATIONAL BUILDING CODE (IBC) & WASHINGTON STATE AMENDMENTS
-2018 INTERNATIONAL MECHANICAL CODE (IMC) & WASHINGTON STATE AMENDMENTS
-2018 UNIFORM PLUMBING CODE (UPC) & WASHINGTON STATE AMENDMENTS
-2018 WASHINGTON STATE ENERGY CODE (WSEC)
-2018 INTERNATIONAL FUEL GAS CODE (IFGC) & WASHINGTON STATE AMENDMENTS
RECEIVED
Jun 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
z
0
0
F-
U)
w
U
�
w
0
LLw
Q
0
0
z
�AF(� �o00
05
nOBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
206-364-3343 TEL
CONTACT: JON ROBISON
J
J
w
Ld
cn
0
0
a
a_
�LJ
LLJ
>
z
z
0
Q
w
cc
LLJ
=
0
0
I U
Q
9
(I
A
Q
CO
o
Z Z
O o
G �
�ZW
WWI
LLj�
000D
Wa.Z
COD
cr
ZQW
�Hp-.
0
w
0
DATE:
05/21 /2021
0
m
w
C9 m
cf) cy)�
o m
cm
LLI
Q m
�z- 0 o
O
p O N
ULj
O
- -1 0-
z
O
0
Vl z
mw
w
0z
0
z
w
SHEET TITLE:
PLUMBING NOTES,
TABLES, AND CODES
SHEET NO.
Pool
❑ ❑ ❑
SEE P2.0 ENLARGED PLANS
SEE
P2.1 ENLARGED PLANS
0 HAIR
SALON I
I I
°
I 125 I
I -----
J
RECEIVED
PROPOSED PLAN
PROPOSED
PLAN
Jun 072021
FIRST FLOOR
SECOND
FLOOR
CITY OF MONDS
DEVELOPMENT SERVICES
DEPARTMENT
SCALE: 3 32" = 1'-0"
SCALE: 3 32" = 1'-0"
cn
Z
z
O
U
F-
U)
IZ
>
0,
w
U
Q-'
cn
w
0
w
Q
0
O
z
❑0OpOo
o° R0e0000
/S
13 �� o : ❑
❑ cn z
❑ ❑
4
0;0�O VFFcisrE�
oo°000N000005�`�1�`��
0
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD,WA98036
206-364-3343 TEL
CONTACT: JON ROBISON
LLI
LLI
(n
O
a
a_
LLJ
z
z
O
CD
U
cif
Q
�n
w
w
w
=
w
0
o
U
Q
Q
AI
Q
CD
09
Z
O Z
50
L 0
Z w
ww
00�
Wa.Z
Colo
Ftza
ZQw
coF-a
U
LLI
O
DATE:
05/21 /2021
N
O
co
LLI
I--
Cf? M Wit'
O (y)
Ld
Q
� c9
Iz— 0 O
p O N
W
O Z Z
J 0—
U
0
Vl j � C�
z
mw
w
0z
0
10 z
w
SHEET TITLE:
FLOOR PLANS -
FIRST & SECOND FLOOR
SHEET NO.
Pi 00
F----------------------------------------
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
L—
PROPOSED PLAN
THIRD FLOOR
RECEIVED
Jun 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
z
O
U
F-
U)
�
w
U
w
w
0
ILL
0
O
z
FGIST�04�
l4k/oaoo0�o
05
nOBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
206-364-3343 TEL
CONTACT: JON ROBISON
J
J
W
W
(n
C�
C�
a_
0_
z
z
o
¢
w
w
cc
LLJ
=
w
0
o
U
¢
Q
(m
Q
0®
Q
c
o
Z Z
O o
G �
Z w
w w >:
o0OD
wa.Z
cA_o
crza
ZQw
CODF-a
U
w
0
DATE:
05/21 /2021
SHEET TITLE:
FLOOR PLAN -
THIRD FLOOR
cv
0
m
w
Qo
M m
� 0 �
m
� OC) m
Q � m
Iz- 0 O
O
O O cv
LJ
� Z Z
-1 00-
z
od
Vl z
mw
w
0z
0
z
w
SHEET NO.
Pi 0 1
SCALE: 3/32" = 1'-O"
FLAG NOTES
1. REMOVE AND REPLACE EXISTING SINK. FURNISH AND INSTALL NEW SINK, FAUCET,
POP UP DRAIN ASSEMBLY AND PLUMBING CONNECTIONS. CONNECT TO EXISTING
PLUMBING LINES.
2. REMOVE AND REPLACE EXISTING HAIR SHAMPOO STATION. CONNECT TO EXISTING
PLUMBING LINES
EXISTING ENLARGED DEMO PLAN
FIRST FLOOR — HAIR SALON
SCALE: 1/2" = 1'-0"
PLUMBING FIXTURE SCHEDULE
PLAN MARK
ROOM LOCATION
SERVICE SIZE — INCHES
FIXTURE TYPE
BASIS OF DESIGN MODEL
NOTES
CW
HW
W
V
S-1
HAIR SALON
1/2
1/2
2
1-1/2
SINGLE BOWL — UNDERMOUNT
JUST SINKS US-1114—A
HAIR SALON
FAUCET
CONTRACTOR TO VERIFY FAUCET MODEL WITH CLIENT.
S-2
HAIR SALON
1/2
1/2
2
1-1/2
PIVOTING BOWL
BELVEDERE 8600
CLO-01
AS REQUIRED
— — —
— — —
— — —
— — —
FLOOR CLEANOUT
JAY R. SMITH 4020
CLO-02
AS REQUIRED
— — —
— — —
— — —
— — —
WALL CLEANOUT
JAY R. SMITH 4402
NEW ENLARGED PROPOSED PLAN
FIRST FLOOR — HAIR SALON
SCALE: 1/2" = 1'-0"
RECEIVED
Jun 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
z
O
0
F-
U)
�
w
U�
w
0
W
0
O
z
AF(� �o00
O
STEIF
��ooaoo00o "1��1
05
nOBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
206-364-3343 TEL
CONTACT: JON ROBISON
J
J
w
w
(n
C�
C�
a_
0_
z
z
o
¢
w
w
cc
LLJ
=
w
0
0
I U
¢
O
(I
O
0®
Q
c
o
Z Z
O o
G �
Z w
ww>
00OD
wa.Z
cA_o
FtZo
Zaw
�Hpw.
I-
U
Iw
0
DATE:
05/21 /2021
0
m
w
�Mm
� 0 �
m
� OC) m
Q � m
Iz— 0 O
O
O O cv
LJ
� � Z
—1 00—
z
0 C&
(j) z
mw
w
0z
0
z
w
SHEET TITLE:
ENLARGED PLAN -
FIRST FLOOR
SHEET NO.
P2mO
FLAG NOTES
1. REMOVE EXISTING VANITY AND SINK. FURNISH AND INSTALL NEW SINK TO
INCLUDE: SINK, LEVER HANDLE FAUCET SET, POP UP DRAIN ASSEMBLY AND
PLUMBING CONNECTIONS. CONNECT TO EXISTING PLUMBING LINES.
EXISTING ENLARGED DEMO PLAN
SECOND FLOOR — NURSE ROOM
SCALE: 1/2" = 1'-0"
PLUMBING FIXTURE SCHEDULE
PLAN MARK
ROOM LOCATION
SERVICE SIZE — INCHES
FIXTURE TYPE
BASIS OF DESIGN MODEL
NOTES
CW
HW
W
V
S-3
NURSE ROOM
1/2
1/2
2
1-1/2
SINGLE BOWL — UNDERMOUNT
BLANCO 441026
NURSE ROOM
FAUCET
MOEN 7735 SRS
SIDE SPRAY NOT INSTALLED
CLO-01
AS REQUIRED
— — —
— — —
— — —
---
FLOOR CLEANOUT
JAY R. SMITH 4020
CLO-02
AS REQUIRED
— — —
— — —
— — —
---
WALL CLEANOUT
I JAY R. SMITH 4402
NEW ENLARGED PROPOSED PLAN
SECOND FLOOR — NURSE ROOM
SCALE: 1/2" = 1'-0"
RECEIVED
Jun 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
z
0
0
F-
U-)
w
V)
w
0
LLW
0
O
z
FGIST�04�
go
0�ooaoo��o "1��1
05
nOBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
206-364-3343 TEL
CONTACT: JON ROBISON
J
J
W
W
(n
C�
C�
a_
0_
z
z
0
¢
w
cc
LLJ
=
0
0
0
¢
O
(I
O
0®
Q
c
o
z Z
O o
G �
Z w
ww>
00OD
wa.Z
cA_o
crZo
Z¢w
�Hpw.
I-
0
w
0
DATE:
05/21 /2021
0
m
w
�Mm
� 0 �
m
� OC) m
Q � m
Iz— 0 O 0
O O cv
LJ
� � Z
-1 00-
z
od
(j) z
mw
w
0z
0
z
w
SHEET TITLE:
ENLARGED PLAN -
SECOND FLOOR
SHEET NO.
P2ml
PLUMBING FIXTURE SCHEDULE
PLAN MARK
ROOM LOCATION
SERVICE SIZE - INCHES
FIXTURE TYPE
BASIS OF DESIGN MODEL
NOTES
CW
HW
W
V
S-4
ACTIVITY ROOM
1/2
1/2
2
1-1/2
SINGLE BOWL - UNDERMOUNT
BLANCO 441026
ACTIVITY ROOM
FAUCET
MOEN 7594EWSRS
S-5
RESIDENT LAUNDRY
1/2
1/2
2
1-1/2
SINGLE BOWL - UNDERMOUNT
BLANCO 441026
RESIDENT LAUNDRY
FAUCET
MOEN 7594EWSRS
S-6
SERVERY
1/2
1/2
2
1-1/2
DOUBLE BOWL - UNDERMOUNT
BLANCO 441020
SERVERY
FAUCET
MOEN 7594EWSRS
S-7
SERVERY
1/2
1/2
2
1-1/2
SINGLE BOWL - UNDERMOUNT
BLANCO 441026
SERVERY
FAUCET
MOEN 7594EWSRS
LAV-1
TOILET
1/2
1/2
2
1-1/2
LAVATORY
TOILET
FAUCET
BRADLEY CROP S53-3100
WC-1
TOILET
1/2
1/2
2
1-1/2
WATER CLOSET
PENGUIN 524
WB-1
LAUNDRY
1/2
1/2
2
1-1/2
WASHER BOX (WASHER)
GUY GRAY 82026
PROIVIDE ANTI -SIPHON DEVICES ON HOSE CONNECTIONS.
WB-2
LAUNDRY
1/2
1/2
- - -
- - -
WASHER BOX (DETERGENT)
GUY GRAY 82026
PROIVIDE ANTI -SIPHON DEVICES ON HOSE CONNECTIONS. CAP
UNUSED DRAIN CONNECTION ON WASHER BOX FOR DETERGENT
DISPENSERS
CLO-01
AS REQUIRED
- - -
- - -
- - -
- - -
FLOOR CLEANOUT
JAY R. SMITH 4020
CLO-02
AS REQUIRED
- - -
- - -
- - -
---
WALL CLEANOUT
JAY R. SMITH 4402
FS-01
PER PLANS
- - -
- - -
2
1-1/2
FLOOR SINK
JAY R. SMITH
FD-01
PER PLANS
---
---
NOTE 2
FLOOR DRAIN
JAY R. SMITH 2O05 SERIES
WITH ADJUSTABLE STRAINER HEADS
NOTES:
(1) PR❑VIDE RED/HOT AND BLUE/COLD WATER INDICAT❑RS TO ALL FIXTURES.
(2) SIZE PER PLANS
(3) FLUSH TRIGGER SHALL BE ON WIDE SIDE OF ROOM
(4) ALL SINKS AND LAVS TO BE PR❑VIDED WITH THERM❑STATIC MIXING VALVES
nnk I TI A I I I A TI nA I Tn C`rnnk Irl r)AIM nr %A/A C`I 1r-r) nnvrC"
_F "LAUNDRY
R HAMMER
(TYP. 4 PLCS.)
W.lkllm�
WASHER SUPPLY AND DRAIN
SCALE: NONE
OVIDE STANDOFF
UNTED TO WALL
' PIPE AIR GAP
NDIRECT DRAIN TO FLOOR SINK
SCALE: NONE
EXISTING ENLARGED DEMO PLAN
THIRD FLOOR
SCALE: 1 /8" = 1'-0"
FLAG NOTES
1. REMOVE AND REPLACE EXISTING SINK. FURNISH AND INSTALL NEW: SINK, FAUCET, POP UP DRAIN ASSEMBLY AND
PLUMBING CONNECTIONS. CONNECT TO EXISTING PLUMBING LINES.
2. REMOVE AND REPLACE EXISTING WATER CLOSET. PROVIDE NEW Y4 TURN STOPS AND SUPPLIES
3. REMOVE AND REPLACE EXISTING LAVATORY. PROVIDE NEW Y4 TURN STOPS AND SUPPLIES.
4. REMOVE EXISTING WASHER BOXES BEHIND WASHING MACHINE. PROVIDE NEW WASHER BOXES AS INDICATED ON
PLANS. PROVIDE SEPARATE BOXES TO SERVE WASHERS AND DETERGENT DISPENSERS. EXTEND AND CONNECT
EXISTING PLUMBING LINES TO NEW WASHER BOXES AS REQUIRED.
5. EXISTING PLUMBING FIXTURES IN SERVING/KITCHEN AREA TO BE DEMO'D AND REMOVED.
6. REMOVE EXISTING REFRIGERATOR AND EXTEND EXISTING PLUMBING CONNECTIONS TO NEW REFRIGERATOR ICE MAKER
CONNECTION. PROVIDE BACKFLOW PREVENTOR.
7. REMOVE EXISTING KITCHEN SINK AND EXTEND EXISTING PLUMBING CONNECTIONS TO NEW KITCHEN SINK. PROVIDE
AIR -GAP CONNECTION FOR DISHWASHER.
8. REMOVE EXISTING DISHWASHER AND EXTEND EXISTING PLUMBING CONNECTIONS TO DISHWASHER.
9. REMOVE EXISTING FOOD WELL. PROVIDE NEW FOOD WELL AT LOCATION SHOWN. PROVIDE NEW FLOOR SINK FOR FOOD
WELL DRAIN. EXTEND EXISTING HOT WATER CONNECTION TO NEW FOOD WELL.
10. PROVIDE NEW SINK AND CW/HW/W/V CONNECTIONS PER SCHEDULE AT LOCATION SHOWN. CONTRACTOR TO FIELD
VERIFY POINTS OF CONNECTION TO EXISTING PLUMBING.
11. EXISTING GAS FIREPLACE TO BE REPLACED WITH NEW. PROVIDE NEW GAS SHUTOFF VALVE AND PRESSURE
REGULATOR. CONNECT TO EXISTING GAS LINE.
PROPOSED ENLARGED PLAN
THIRD FLOOR
SCALE: 1 /8" = 1'-0"
RECEIVED
Jun 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
z
0
0
F-
U)
>
�w
U
w
0
ILL
0
0
z
�AFc��o00
O
,%0'� /O aoo00o "1��1
05
nOBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
206-364-3343 TEL
CONTACT: JON ROBISON
J
J
W
Ld
(n
C�
C�
a_
a_
LLJ
z
z
0
¢
w
cc
LLJ
=
0
o
U
¢
I-
U
w
0
DATE:
05/21 /2021
0
w
C9 m
� 0 Wit'
m
� � m
Q � m
Iz- 0 O 0
O O cv
LJ
� � Z
rn -1 0-
z
0 &
Vl z
mw
w
0z
0
z
w
SHEET TITLE:
ENLARGED PLAN -
THIRD FLOOR
SHEET NO.
P2m2