APPROVED BLD PLN RESUB 1-Architectural_Planw cn �_ w HUTMACHER DECK SHEET INDEX S1O0 SHEET INDEX &GENERAL STRUCTURAL NOTES S1O1 GENERAL STRUCTURAL NOTES S2O0 PLANS &DETAILS S3O0 DETAILS STRUCTURAL NOTES GENERAL REQUIREMENTS BUILDING CODE &REFERENCE STANDARDS: THE "INTERNATIONAL BUILDING CODE" (IBC), 2018 EDITION, AS ADOPTED AND MODIFIED BY THE CITY OF EDMUNDS, GOVERNS THE DESIGN AND CONSTRUCTION OF THIS PROJECT. REFERENCE TO A SPECIFIC SECTION IN THE CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE MATERIALS REFERENCE STANDARDS NOTED BELOW. THE LATEST EDITION OF THE MATERIALS REFERENCE STANDARDS SHALL BE USED. SCOPE OF STRUCTURAL WORK: STRUCTURAL DESIGN OF REPLACEMENT DECK. DEFINITIONS: THE FOLLOWING DEFINITIONS APPLY TO THESE GENERAL NOTES: • "STRUCTURAL ENGINEER OF RECORD" (EOR) -THE STRUCTURAL ENGINEER WHO IS LEGALLY RESPONSIBLE FOR STAMPING &SIGNING THE STRUCTURAL DOCUMENTS FOR THE PROJECT. THE FOR IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM. • "SPECIALTY STRUCTURAL ENGINEER" (SSE) - A LICENSED PROFESSIONAL ENGINEER, NOT THE EOR, WHO PERFORMS SPECIALTY STRUCTURAL ENGINEERING SERVICES NECESSARY TO COMPLETE THE STRUCTURE, WHO HAS EXPERIENCE AND TRAINING IN THE SPECIFIC SPECIALTY. THE GENERAL CONTRACTOR, SUBCONTRACTOR, OR SUPPLIER WHO IS RESPONSIBLE FOR THE DESIGN, FABRICATION AND INSTALLATION OF SPECIALTY -ENGINEERED ELEMENTS SHALL RETAIN THE SSE. SUBMITTALS SHALL BE STAMPED AND SIGNED BY THE SSE. DOCUMENTS STAMPED AND SIGNED BY THE SSE SHALL BE COMPLETED BY OR UNDER THE DIRECT SUPERVISION OF THE SSE WITH A PE OR SE LICENSE ISSUED BY THE STATE OF WASHINGTON. • "DEFERRED SUBMITTALS -DEFERRED SUBMITTAL IS ENGINEERING WORK TO BE DESIGNED -BY -OTHERS OR BIDDER -DESIGNED. NOTE PRIORITIES: NOTES ON THE INDIVIDUAL DRAWINGS SHALL GOVERN OVER THESE GENERAL NOTES. SPECIFICATIONS: REFER TO THESE NOTES, STRUCTURAL DRAWINGS, AND ARCHITECTURAL DRAWINGS WHICH SERVE AS SPECIFICATIONS FOR THIS PROJECT. STRUCTURAL DETAILS: THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THE PROJECT AND ARE NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. STRUCTURAL RESPONSIBILITIES: THE FOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE PRIMARY STRUCTURE IN ITS COMPLETED STATE. CONTRACTOR RESPONSIBILITIES: THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND WSHA. THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE TEMPORARY SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE IS COMPLETED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. THE CONTRACTOR SHALL SUBMIT PLANS SHOWING THE LOCATION, WEIGHT, SIZE AND ANCHORAGE OF ALL HANGERS SUPPORTING ALL MECHANICAL, ELECTRICAL, PLUMBING OR SPRINKLER LOADS IN EXCESS OF 50 POUNDS. ALL ROOF -MOUNTED EQUIPMENT SHALL BE INCLUDED ON THESE PLANS AND SHALL SHOW THE WEIGHTS, SIZES, MOUNTING/ATTACHMENT DETAILS, AND LOCATIONS. SUBMIT PLANS TO THE FOR FOR REVIEW PRIOR TO INSTALLATION. DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THESE GENERAL NOTES, THE CONTRACT DRAWINGS AND SPECIFICATIONS, AND/OR REFERENCE STANDARDS, THE FOR SHALL DETERMINE WHICH SHALL GOVERN. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE FOR BEFORE PROCEEDING WITH THE WORK. ACCORDINGLY, ANY CONFLICT IN OR BETWEEN THE CONTRACT DOCUMENTS SHALL NOT BE A BASIS FOR ADJUSTMENT IN THE CONTRACT PRICE. SITE VERIFICATION: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO FABRICATION AND/OR CONSTRUCTION. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE FOR BEFORE PROCEEDING WITH THE WORK. ALL UNDERGROUND UTILITIES SHALL BE DETERMINED BY THE CONTRACTOR PRIOR TO EXCAVATION OR DRILLING. ADJACENT UTILITIES: THE CONTRACTOR SHALL DETERMINE THE LOCATIONS OF ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO EXCAVATION. ANY UTILITY INFORMATION SHOWN ON THE DRAWINGS AND DETAILS IS APPROXIMATE AND NOT NECESSARILY COMPLETE. DESIGN CRITERIA CONSTRUCTION LOADS: LOADS ON THE STRUCTURE DURING CONSTRUCTION SHALL NOT EXCEED THE DESIGN LOADS OR THE CAPACITY OF THE PARTIALLY COMPLETED CONSTRUCTION. SNOW LOAD:THE ROOF SNOW LOAD IS DETERMINED BY USING CHAPTER 7 OF ASCE 7-16 IN ACCORDANCE WITH IBC SECTION 1608 AND WITH THE FOLLOWING FACTORS: MINIMUM ROOF DESIGN LOAD 25 PSF WITHOUT DRIFT GROUND SNOW LOAD, PG = 25 PSF IMPORTANCE FACTOR, IS = 1.0 FLAT ROOF SNOW LOAD, PF = 25 PSF THERMAL FACTOR, CT = 1.0 WIND DESIGN: WIND LOAD IS DETERMINED USING CHAPTER 28 OF ASCE 7-16 IN ACCORDANCE WITH IBC SECTION 1609 WITH THE FOLLOWING FACTORS: BASIC WIND SPEED (3-SECOND GUST) V = 97 MPH WIND IMPORTANCE FACTOR IW = 1.0 RISK -CATEGORY = II EXPOSURE CATEGORY = B GCPI = tO.18 Kzt=1.0 SEISMIC DESIGN: EARTHQUAKE DESIGN IS DETERMINED USING CHAPTER 12 ASCE 7-16 IN ACCORDANCE WITH IBC CHAPTER 16 WITH THE FOLLOWING FACTORS: IMPORTANCE FACTOR IE = 1.0 RISK CATEGORY= II SS = 1.277 G SDS = 1.022 G S 1 = 0.448 G S D 1 = 0.448 G SITE CLASS = D SEISMIC DESIGN CATEGORY = D WOOD STRUCTURE (SUPER -STRUCTURE • BASIC SEISMIC FORCE RESISTING SYSTEM: A-15 (BEARING WALL SYSTEMS) LIGHT -FRAMED WALLS WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE • ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE, PER ASCE 7-16, SECTION 12.8 • R = 6.5 • CS=0.14 • CD=4 DESIGN BASE SHEAR: DESIGN BASE SHEAR SEISMIC GOVERNED N/S V = 19.1 K. DEFLECTIONS: FLOOR TOTAL LOAD DEFLECTION LIMIT: L/36O FLOOR LIVE LOAD DEFLECTION LIMIT: L/48O ROOF TOTAL LOAD DEFLECTION LIMIT: L/24O ROOF LIVE LOAD DEFLECTION LIMIT: L/36O LIVE LOADS: ROOF (LIVE) 20 PSF ROOF (SNOW) 25 PSF RESIDENTIAL FLOOR 40 PSF DECK 1.5X OCCUPANCY SERVED ALTERNATES: PRODUCT OR MANUFACTURER COMPONENTS SPECIFIED IN THESE DRAWINGS ARE USED AS THE BASIS OF DESIGN FOR THIS PROJECT. ALTERNATES FOR SPECIFIED ITEMS MAY BE SUBMITTED TO THE FOR FOR REVIEW. HOWEVER, CONTRACTOR SHALL SUBMIT A CURRENT ICC-ESR/IAPMO-ER REPORT IDENTIFYING THAT AN ALTERNATIVE COMPONENT HAS THE SAME OR GREATER LOAD CAPACITY THAN THE SPECIFIED ITEM. SHOP DRAWING REVIEW: REVIEW BY THE ARCHITECT/EOR IS FOR GENERAL COMPLIANCE WITH THE DESIGN CONCEPT AND THE CONTRACT DOCUMENTS. DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE EOR, AND THEREFORE, MUST BE VERIFIED BY THE GENERAL CONTRACTOR. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM COMPLIANCE WITH THE PROJECT PLANS AND SPECIFICATIONS, NOR DEPARTURES THEREFROM. THE CONTRACTOR REMAINS RESPONSIBLE FOR DETAILS AND ACCURACY; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY; AND FOR PERFORMING WORK IN A SECURE MANNER. WHEN SHOP DRAWINGS (COMPONENT DESIGN DRAWINGS) DIFFER FROM OR ADD TO THE REQUIREMENTS OF THE STRUCTURAL DRAWINGS THEY SHALL BE DESIGNED AND STAMPED BY THE RESPONSIBLE SSE. ALLOW ONE WEEK FOR FOR REVIEW TIME. DEFERRED SUBMITTALS: PER IBC SECTION 107.3.4.1, DRAWINGS, CALCULATIONS, AND PRODUCT DATA FOR THE DESIGN AND FABRICATION OF ITEMS THAT ARE DESIGNED -BY -OTHERS SHALL BEAR THE SEAL AND SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER (SSE) WHO IS RESPONSIBLE FOR THE DESIGN AND SHALL BE SUBMITTED TO THE ARCHITECT/EOR AND THE BUILDING DEPARTMENT FOR REVIEW PRIOR TO FABRICATION. ALLOW ONE WEEK FOR FOR REVIEW TIME. THE SSE SHALL SUBMIT STAMPED AND SIGNED CALCULATIONS AND SHOP DRAWINGS TO THE FOR FOR REVIEW. REVIEW OF THE SSE'S SHOP DRAWINGS IS FOR GENERAL COMPLIANCE WITH DESIGN CRITERIA AND COMPATIBILITY WITH THE DESIGN OF THE PRIMARY STRUCTURE AND DOES NOT RELIEVE THE SSE OF RESPONSIBILITY FOR THAT DESIGN. ALL NECESSARY BRACING, TIES, ANCHORAGE, AND PROPRIETARY PRODUCTS SHALL BE FURNISHED AND INSTALLED PER MANUFACTURER'S INSTRUCTIONS OR THE SSE'S DESIGN DRAWINGS AND CALCULATIONS. SUBMITTED DRAWINGS SHALL INDICATE ALL REACTION FORCES IMPARTED TO THE PRIMARY STRUCTURE. THE DESIGN OF THE CONNECTION TO THE PRIMARY STRUCTURE IS THE RESPONSIBILITY OF THE SUPPLIER AND SSE. SUBMITTED CALCULATIONS ARE FOR CURSORY REVIEW ONLY AND WILL GENERALLY NOT BE RETURNED. STRUCTURAL MEMBERS WITHOUT ADDITIONAL BRACING OF THOSE MEMBERS TO ELIMINATE TORSIONAL FORCES. TORSIONAL BRACING SHALL BE DESIGNED BY THE NONSTRUCTURAL COMPONENT DESIGNER AND APPROVED BY THE EOR. ANCHORAGE TO THE PRIMARY STRUCTURE IS PER THE BIDDER -DESIGN CONTRACTOR OR SUPPLIER. TESTS &INSPECTIONS INSPECTIONS: ALL CONSTRUCTION IS SUBJECT TO INSPECTION BY THE BUILDING OFFICIAL IN ACCORDANCE WITH IBC SEC 110. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED INSPECTIONS WITH THE BUILDING OFFICIAL. SUBMIT COPIES OF ALL INSPECTION REPORTS TO THE ARCHITECT/EOR FOR REVIEW. THE BUILDING OFFICIAL MAY ACCEPT INSPECTION OF AND REPORTS BY APPROVED INSPECTION AGENCIES IN LIEU OF BUILDING OFFICIAL'S INSPECTIONS. THE CONTRACTOR SHALL OBTAIN APPROVAL OF BUILDING OFFICIAL TO USE THE THIRD -PARTY INSPECTION AGENCY AND CONTRACTOR SHALL ALERT THE ARCHITECT/EOR AS SUCH. SPECIAL INSPECTIONS: IN ADDITION TO THE INSPECTIONS REQUIRED BY IBC SEC 110, A SPECIAL INSPECTOR SHALL BE HIRED BY THE OWNER AS AN INDEPENDENT THIRD -PARTY INSPECTOR TO PERFORM THE SPECIAL INSPECTIONS PER IBC CH. 17. SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN APPROVED TESTING AGENCY AS OUTLINED IN THE SPECIAL INSPECTION SCHEDULE, THE CONTRACT DOCUMENTS, AND/OR THE PROJECT SPECIFICATION. SPECIAL INSPECTIONS SHALL MEET THE REQUIREMENTS OUTLINES IN THE SPECIFIC MATERIALS SECTIONS OF IBC SEC 1705. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE INSPECTIONS, AS REQUIRED PER THE CITY/BUILDING OFFICIAL. SPECIAL INSPECTIONS SHALL BE PERFORMED AS INDICATED IN THE STRUCTURAL INSPECTION SCHEDULE AS REQUIRED PER THE CITY/BUILDING OFFICIAL. SOILS AND FOUNDATIONS REFERENCE STANDARDS: CONFORM TO IBC CHAPTER 18 "SOILS AND FOUNDATIONS." GEOTECHNICAL INSPECTION: SITE SOIL CONDITIONS, FILL PLACEMENT, AND LOAD -BEARING REQUIREMENTS SHALL BE AS REQUIRED BY SECTION 1705.E AND TABLE 1705.E AND/OR AS REQUIRED IN THE GEOTECHNICAL REPORT. DESIGN SOIL VALUES: ALLOWABLE SOIL BEARING PRESSURE EXISTING FOUNDATIONS 1500 PSF DL + LL 2000 PSF DL + LL +SEISMIC/WIND SLABS -ON -GRADE &FOUNDATIONS: ALL SLABS -ON -GRADE AND FOUNDATIONS SHALL BEAR ON STRUCTURAL COMPACTED FILL OR COMPETENT NATIVE SOIL PER THE GEOTECHNICAL REPORT OR AS NOTED IN THESE DOCUMENTS. EXTERIOR PERIMETER FOOTINGS SHALL BEAR NOT LESS THAN 18 INCHES BELOW FINISH GRADE, OR AS REQUIRED BY THE GEOTECHNICAL ENGINEER AND THE BUILDING OFFICIAL. INTERIOR FOOTINGS SHALL BEAR NOT LESS THAN 12 INCHES BELOW FINISH FLOOR. FOUNDATION STEM WALLS: UNLESS OTHERWISE NOTED ON THE DRAWINGS, THE MAXIMUM UNBALANCED SOIL CONDITION FOR ALL FOUNDATION STEM WALLS (DIFFERENCE IN ELEVATION BETWEEN INTERIOR AND EXTERIOR SOIL GRADES) SHALL BE 2'-6". MAINTAIN A MINIMUM 8" SEPARATION BETWEEN FINISH GRADE AND UNTREATED WOOD FRAMING. BACKFILLING: BACKFILL BEHIND RETAINING AND FOUNDATION WALLS SHALL BE OF FREE -DRAINING MATERIAL PLACED IN MAXIMUM LOOSE LIFTS OF 12" OR AS DIRECTED BY THE GEOTECHNICAL REPORT. BACKFILL BEHIND WALLS SHALL NOT BE PLACED BEFORE THE WALL IS PROPERLY SUPPORTED BY THE FLOOR SLAB OR TEMPORARY BRACING. BACKFILL SHALL BE COMPACTED USING HAND -OPERATED EQUIPMENT ONLY. THE CONTRACTOR SHALL REFRAIN FROM OPERATING HEAVY EQUIPMENT BEHIND RETAINING AND FOUNDATION WALLS WITHIN A DISTANCE EQUAL TO OR GREATER THAN THE HEIGHT OF THE WALL, UNLESS OTHERWISE APPROVED BY THE EOR. ALL TOPSOIL ORGANICS AND LOOSE SURFACE SOIL SHALL BE REMOVED FROM BENEATH FILL SUPPORTING CONCRETE SLAB OR PAVING. CAST -IN -PLACE CONCRETE REFERENCE STANDARDS: CONFORMS TO THE LATEST EDITIONS OF THE FOLLOWING: (1) ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY". (2) IBC CHAPTER 19. FIELD REFERENCE: THE CONTRACTOR SHALL KEEP A COPY OF ACI FIELD REFERENCE MANUAL, SP-15, "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301) WITH SELECTED ACI AND ASTM REFERENCES." CONCRETE MIXTURES: CONFORM TO ACI 318 CHAPTER 19 "CONCRETE: DESIGN AND DURABILITY REQUIREMENTS." MATERIALS: CONFORM TO ACI 318 CHAPTERS 19 & 20. SUBMITTALS: PROVIDE ALL SUBMITTALS REQUIRED BY ACI 301 SEC 4.1.2. SUBMIT MIX DESIGNS FOR EACH MIX IN THE TABLE BELOW. TABLE OF MIX DESIGN REQUIREMENTS MEMBER STRENGTH TEST AGE MAXIMUM EXPOSURE MAX MINIMUM TYPE/LOCATION (PSI) (DAYS) AGGREGATE CLASSIFICATION W/C RATIO AIR CONTENT FDN -RESIDENTIAL FTG 3500 28 1 " F1, CO 0.45 (0.55 MAX) 4.5% MIX DESIGN NOTES: (1) W/C RATIO: WATER-CEMENTITIOUS MATERIAL RATIOS SHALL BE BASED ON THE TOTAL WEIGHT OF CEMENTITIOUS MATERIALS. RATIOS NOT SHOWN IN THE TABLE ABOVE ARE CONTROLLED BY STRENGTH REQUIREMENTS. (2) CEMENTITIOUS CONTENT: a. THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL CONFORM TO ACI 301 SEC 4.2.2 9B. MAXIMUM AMOUNT OF FLY ASH SHALL BE 20% OF TOTAL CEMENTITIOUS CONTENT UNLESS REVIEWED AND APPROVED OTHERWISE BY EOR. b. FOR CONCRETE USED IN ELEVATED FLOORS, PORTLAND CEMENT CONTENT SHALL CONFORM TO ACI 301 SEC 4.2.2.1. ACCEPTANCE OF LOWER CEMENT CONTENT IS CONTINGENT ON PROVIDING SUPPORTING DATA TO THE FOR FOR REVIEW AND ACCEPTANCE. (1) AIR CONTENT: CONFORM TO ACI 301 SEC 4.2.2.4. HORIZONTAL EXTERIOR SURFACES IN CONTACT WITH THE SOIL REQUIRE ENTRAINED AIR. USE EXPOSURE CATEGORY F0, S0, W0, AND CO UNLESS NOTED OTHERWISE. TOLERANCE IS +/- 1.5%. AIR CONTENT SHALL BE MEASURED AT POINT OF PLACEMENT. (2) EXPOSURE CLASSIFICATION: THE MIX DESIGN PROVIDED SHALL MEET THE REQUIREMENTS OF ACI 318 CHAPTER 19, BASED ON THE EXPOSURE CLASSIFICATION INDICATED IN THE TABLE ABOVE. (3) SLUMP: UNLESS OTHERWISE SPECIFIED OR PERMITTED, CONCRETE SHALL HAVE AT THE POINT OF DELIVERY, A SLUMP OF 4" +/- 1". FOR ADDITIONAL CRITERIA, REFERENCE ACI 301 SEC 4.2.2.2. (4) NON -CHLORIDE ACCELERATOR: NON -CHLORIDE ACCELERATING ADMIXTURE MAY BE USED IN CONCRETE SLABS PLACED AT AMBIENT TEMPERATURES BELOW 50F AT THE CONTRACTOR'S OPTION. FORMWORK: CONFORM TO ACI 301 SEC 2 "FORMWORK AND FORM ACCESSORIES." REMOVAL OF FORMS SHALL CONFORM TO SEC 2.3.2 EXCEPT STRENGTH INDICATED IN SEC 2.3.2.5 SHALL BE 0.75 F'C. MEASURING, MIXING, AND DELIVERY: CONFORM TO ACI 301 SEC 4.3. HANDLING, PLACING, CONSTRUCTING, AND CURING: CONFORM TO ACI 301 SEC 5. EMBEDDED ITEMS: POSITION AND SECURE IN PLACE EXPANSION JOINT MATERIAL, ANCHORS AND OTHER STRUCTURAL AND NON-STRUCTURAL EMBEDDED ITEMS BEFORE PLACING CONCRETE. CONTRACTOR SHALL REFER TO MECHANICAL, ELECTRICAL, PLUMBING, AND ARCHITECTURAL DRAWINGS AND COORDINATE ALL OTHER EMBEDDED ITEMS. GROUTED REBAR AND ANCHOR BOLTS: FOLLOW MANUFACTURER'S WRITTEN INSTRUCTIONS: DRILL HOLES IN EXISTING CONCRETE TO DEPTH NOTED ON PLANS OR TO DEPTH AS NECESSARY TO DEVELOP THE STRENGTH OF THE REBAR LISTED IN THE MANUFACTURER'S ICC-ESR/IAPMO-ER REPORT. DRILL THE HOLE DIAMETER PER MANUFACTURER'S INSTRUCTIONS. ROUGHEN SIDES OF HOLES BY PERCUSSIVE DRILLING METHODS. HOLES SHALL BE BRUSHED AND BLOWN FREE OF DEBRIS AND SURFACE RESIDUE BEFORE GROUTING OPERATION. SPECIAL INSPECTION IS REQUIRED. CONCRETE REINFORCEMENT REFERENCE STANDARDS: CONFORM T0: (1) ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE."SEC 3" REINFORCEMENT, AND REINFORCEMENT SUPPORTS." (2) IBC CHAPTER 19, CONCRETE. (3) ACI 318 AND ACI 318R. (4) ACI SP-66 "ACI DETAILING MANUAL" INCLUDING ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT." (5) CRSI MSP-2 "MANUAL OF STANDARD PRACTICE." (6) ANSI/AWS D1.4 "STRUCTURAL WELDING CODE -REINFORCING STEEL." SUBMITTALS: CONFORM TO ACI 301 SEC 3.1.1 "SUBMITTALS, DATA, AND DRAWINGS." SUBMIT PLACING DRAWINGS SHOWING FABRICATION DIMENSIONS AND LOCATIONS FOR PLACEMENT OF REINFORCEMENT AND REINFORCEMENT SUPPORTS. MATERIALS: REINFORCING BARS ASTM A615, GRADE 60, DEFORMED BARS. BAR SUPPORTS CRSI MSP-2, CHAPTER 3 "BAR SUPPORTS." TIE WIRE 16.5 GAGE OR HEAVIER, BLACK ANNEALED. FABRICATION: CONFORM TO ACI 301, SEC 3.2.2 "FABRICATION," AND ACI SP-66 "ACI DETAILING MANUAL." WELDING: BARS SHALL NOT BE WELDED UNLESS AUTHORIZED. WHEN AUTHORIZED, CONFORM TO ACI 301, SEC 3.2.2.2. "WELDING" AND PROVIDE ASTM A706, GRADE 60 REINFORCEMENT. PLACING: CONFORM TO ACI 301, SEC 3.3.2 "PLACEMENT." PLACING TOLERANCES SHALL CONFORM TO SEC 3.3.2.1 "TOLERANCES." CONCRETE COVER: CONFORM TO THE FOLLOWING COVER REQUIREMENTS FROM ACI 301, TABLE 3.3.2.3. CONCRETE CAST AGAINST EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER (#5 &SMALLER) 1-1/2" CONCRETE EXPOSED TO EARTH OR WEATHER (#6 &LARGER) 2" BARS IN SLABS AND WALLS 3/4" SPLICES &DEVELOPMENT LENGTH: CONFORM TO ACI 301, SEC 3.3.2.7. REFER TO "LAP SPLICE &DEVELOPMENT SCHEDULE" ON PLANS FOR TYPICAL SPLICES. THE SPLICES AND DEVELOPMENT LENGTHS INDICATED ON INDIVIDUAL SHEETS CONTROL OVER THE SCHEDULE. USE CLASS B SPLICES UNLESS OTHERWISE NOTED. MECHANICAL CONNECTIONS MAY BE USED WHEN APPROVED BY THE EOR. REINFORCING BAR CHART BAR SIZE TOP BARS OTHER BARS DEVELOPMENT LENGTH, Ld #4 33" 25" 19" #5 41 " 31 " 24" #6 48" 37" 29" #7 70" 54" 41" #8 80" 62" 47" #9 90" 70" 53" #10 100" 78" 59>, #11 110" 85" 65" SCHEDULE NOTES: 1. ALL LENGTHS ARE IN INCHES AND FOR f'c= 4,000 PSI. 2. "TOP BARS" ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12" OF CONC IS CAST IN THE MEMBER BELOW THE BAR. 3. FOR f'c = 5,000 PSI USE 90% OF LENGTH. 4. FOR f'c = 3,000 PSI USE 115% OF LENGTH. FIELD BENDING: CONFORM TO ACI 301 SEC 3.3.2.8. "FIELD BENDING OR STRAIGHTENING." BAR SIZES #3 THROUGH �5 MAY BE FIELD BENT COLD THE FIRST TIME. OTHER BARS REQUIRE PREHEATING. DO NOT TWIST BARS. STRUCTURAL STEEL DESIGN STANDARDS: STRUCTURAL STEEL FOR THIS PROJECT IS DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE AISC STEEL CONSTRUCTION MANUAL. REFERENCE STANDARDS: CONFORM T0: (1) AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS &BRIDGES." (2) RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A49O BOLTS." (3) AWS D1.1 "STRUCTURAL WELDING CODE -STEEL." (4) AWS D1.3 `STRUCTURAL WELDING CODE -SHEET STEEL." (5) AWS D1.8 `STRUCTURAL WELDING CODE -SEISMIC SUPPLEMENT." (6) AISC 341 "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS." (7) ASCE 3 "STANDARD FOR THE STRUCTURAL DESIGN OF COMPOSITE SLABS." MATERIALS: ANCHOR BOLTS &BOLTS IN WOOD ASTM A307 NUTS ASTM A563 OR ASTM A194, GRADE 2H WASHERS (FLAT OR BEVELED) ASTM F436 ANCHOR RODS (HOOKED, HEADED, THREADED/NUTTED)ASTM F1554, GRADE 36 [WELDABLE] THREADED RODS ASTM A36, FY = 36 KSI WELDING ELECTRODES E70XX, 70 KSI, LOW HYDROGEN, TYPICAL CONCRETE SCREWS SIMPSON TITEN HD WOOD FRAMING REFERENCE STANDARDS: CONFORM T0: (1) IBC CHAPTER 23 "WOOD." (2) NDS AND NDS SUPPLEMENT - "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION." (3) ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL -PLATE -CONNECTED WOOD TRUSS CONSTRUCTION." (4) BCSI 2013 `BUILDING COMPONENT SAFETY INFORMATION." IDENTIFICATION: ALL SAWN LUMBER AND PRE -MANUFACTURED WOOD PRODUCTS SHALL BE IDENTIFIED BY THE GRADE MARK OR A CERTIFICATE OF INSPECTION ISSUED BY THE CERTIFYING AGENCY. MATERIALS: SAWN LUMBER: CONFORM TO GRADING RULES OF WWPA, WCLIB, OR NLGA. FINGER JOINTED STUDS ACCEPTABLE AT INTERIOR NON-STRUCTURAL WALLS ONLY. MEMBER USE SIZE SPECIES GRADE STUDS &PLATES 2X4,3X4,2X6,3X6 HF N0. 2 POSTS 4X4, 4X6, 4X8 HF N0. 2 JOISTS 2X6 -- 2X12 HF N0. 2 BEAMS 4X8 -- 4X12 HF N0. 2 BEAMS 6X8 -- 6X12 HF N0. 2 POSTS 6X6, 8X8 HF N0. 2 P.T. FRAMING HF N0. 2 GLUED LAMINATED TIMBER: CONFORM TO AITC 117 "STANDARD SPECIFICATIONS FOR STRUCTURAL GLUED LAMINATED TIMBER OF SOFTWOOD SPECIES, MANUFACTURING AND DESIGN" AND ANSI/AITC A19O.1 "STRUCTURAL GLUED LAMINATED TIMBER." GLUED LAMINATED MEMBER BEAMS SHALL NOT BE CAMBERED, UNLESS SHOWN OTHERWISE ON THE PLANS OR SPECIFICATIONS. MEMBER USE SIZES SPECIES STRESS CLASS USES BEAMS ALL DF/DF 24F-V4 ALL SPANS WOOD STRUCTURAL SHEATHING (PLYWOOD: WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES: ALL VENEER PLYWOOD, ORIENTED STRAND BOARD, WAFERBOARD, PARTICLEBOARD, T1-11 SIDING, AND COMPOSITES OF VENEER AND WOOD BASED MATERIAL. CONFORM TO PRODUCT STANDARDS PS-1-95 AND PS-2-92 OF THE U.S. DEPT. OF COMMERCE AND THE AMERICAN PLYWOOD ASSOCIATION (APA) MINIMUM APA RATING LOCATION THICKNESS SPAN RATING PLYWOOD GRADE EXPOSURE WALLS 15/32" 32/16 C-D 1 JOIST HANGERS AND CONNECTORS: SIMPSON STRONG -TIE COMPANY INC. AS SPECIFIED IN THEIR LATEST CATALOGS WAS USED AS THE BASIS OF DESIGN FOR THIS PROJECT. ALTERNATE CONNECTORS BY OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC-ESR/IAPMO-ER APPROVAL FOR EQUIVALENT OR GREATER LOAD CAPACITIES AND ARE REVIEWED AND APPROVED BY THE FOR PRIOR TO ORDERING. CONNECTORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE 1/2 OF THE NAILS OR BOLTS IN EACH MEMBER. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE FULL LENGTH COMMON. NAIL STRAPS TO WOOD FRAMING AS LATE AS POSSIBLE IN THE FRAMING PROCESS TO ALLOW THE WOOD TO SHRINK AND THE BUILDING TO SETTLE. NAILS AND STAPLES: CONFORM TO IBC SEC 2303.E "NAILS AND STAPLES." UNLESS NOTED ON PLANS, NAIL PER IBC TABLE 2304.10.1. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE COMMON. NAIL SIZES SPECIFIED ON THE DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: COMMON NAILS z O w w a 0 LLJ W _z z LLJ � U I� z Q o z � � z � °' = Q ��� a � z � Q w J z z z � � o w � � � � O N O � � � W � O � � U 0 Q W � � DO Lx� � � � 0 Z U W W � _ � _ � � Q W � W � Q � � _ W = � � � W o� � 0 N SIZE LENGTH DIAMETER 8D 2-1/2" 0.131" 1OD 3" 0.148" 16D 3-1 /2" 0.162" C H K BY: D RW BY: 16D SINKER 3-1/4' 0.148` L2E L2E LAG BOLTS/BOLTS: CONFORM TO ASTM A3O7. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. WOOD HOEDOWNS: HOEDOWNS SPECIFIED ARE AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY INC. ADDITIONAL FRAMING MEMBERS SHALL BE PROVIDED PER THE MANUFACTURER'S REQUIREMENTS. ACCEPTABLE EQUIVALENT PRODUCT SUBSTITUTIONS ARE AVAILABLE FROM OTHER MANUFACTURERS WITH FOR APPROVAL. DO NOT COUNTERSINK HOEDOWN BOLTS. SCALE: AS SHOWN BAR = 1" FULL SIZE DATE: 2021.07.02 NAILING REQUIREMENTS: PROVIDE MINIMUM NAILING IN ACCORDANCE WITH IBC TABLE 2304.10.1 "FASTENING SCHEDULE" EXCEPT AS NOTED ON THE DRAWINGS. NAILING FOR ROOF/FLOOR DIAPHRAGMS/SHEAR WALLS SHALL BE PER DRAWINGS. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE OF JOB N0: 20-060 SHEATHING. SHEET: 1 OF 4 NON-STRUCTURAL COMPONENTS: DESIGN, DETAILING AND ANCHORAGE OF ALL NONSTRUCTURAL COMPONENTS SHALL BE IN ACCORDANCE WITH ASCE 7-16, CHAPTER 13 AND THE PROJECT SPECIFICATIONS. NONSTRUCTURAL COMPONENTS DESIGNED BY OTHERS SHALL NOT INDUCE TORSIONAL LOADING INTO SUPPORTING STEEL STANDARD LIGHT -FRAME CONSTRUCTION: UNLESS NOTED ON THE DRAWINGS, CONSTRUCTION SHALL CONFORM TO IBC SEC 2308 "CONVENTIONAL LIGHT -FRAME CONSTRUCTION" AND IBC SEC 2304 "GENERAL CONSTRUCTION REQUIREMENTS." DWG N0: 5100 (1) WALL FRAMING (UNLESS NOTED OTHERWISE ON PLANS AND DETAILS) ALL INTERIOR WALLS SHALL BE 2X4 � 16"OC AND ALL EXTERIOR WALLS SHALL BE 2X6 � 16"OC. PROVIDE (2) BUNDLED STUDS MIN AT WALL ENDS AND EACH SIDE OF ALL OPENINGS. ALL SOLID SAWN LUMBER BEAMS AND HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (2) TRIM AND (1) KING STUD AND ALL GLULAM OR ENGINEERED WOOD BEAMS AND HEADERS BY (2) TRIM AND (2) KING STUDS. PROVIDE MINIMUM (2) 2X8 HEADERS AT ALL INTERIOR AND EXTERIOR WALL OPENINGS. STITCH -NAIL BUNDLED STUDS WITH (2) 10D � 12"OC. PROVIDE SOLID BLOCKING THRU FLOORS TO SUPPORTS BELOW FOR BEARING WALLS AND POSTS. ATTACH BOTTOM PLATES OF STUD WALLS TO WOOD FRAMING BELOW WITH 16D ®12"OC OR TO CONCRETE WITH 5/8"-DIA. ANCHOR BOLTS X 7" EMBEDMENT AT 48"OC. REFER TO SHEAR WALL SCHEDULE FOR SPECIFIC SHEATHING, STUD, AND NAILING REQUIREMENTS AT SHEAR WALLS. PROVIDE GYPSUM SHEATHING ON INTERIOR SURFACES AND PLYWOOD SHEATHING ON EXTERIOR SURFACES. (2) ROOF/FLOOR FRAMING: (UNLESS NOTED OTHERWISE ON PLANS AND DETAILS) PROVIDE DOUBLE JOISTS/RAFTERS UNDER ALL PARALLEL BEARING PARTITIONS AND SOLID BLOCKING AT ALL BEARING POINTS. PROVIDE DOUBLE JOISTS AROUND ALL ROOF/FLOOR OPENINGS. MULTI-JOISTS/RAFTERS SHALL BE STITCH -NAILED TOGETHER WITH (2)10D � 12"OC. PROVIDE ROOF SHEATHING EDGE CLIPS CENTERED BETWEEN FRAMING AT UNBLOCKED PLYWOOD EDGES. ALL FLOOR SHEATHING SHALL HAVE TONGUE AND GROOVE JOINTS OR BE SUPPORTED BY SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ROOF/FLOOR SHEATHING. ROOF/FLOOR SHEATHING SHALL BE LAID FACE GRAIN PERPENDICULAR TO FRAMING MEMBERS. MOISTURE CONTENT: WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF 19� EXCEPT FOR THE PRESSURE -TREATED WOOD SILL PLATE. REFER TO TESTING &INSPECTIONS FOR THE VERIFICATION OF THESE LIMITS. THE MAXIMUM MOISTURE CONTENT REQUIRED MAY BE LESS THAN 19� WHEN BASED ON A PARTICULAR CLADDING/INSULATION SYSTEM. REFER TO THE ARCHITECT'S DRAWINGS, AND PROJECT SPECIFICATIONS, OR WITH CLADDING INSTALLER FOR MAXIMUM RECOMMENDED MOISTURE CONTENT. CLADDING COMPATIBILITY: THE ARCHITECT/OWNER SHALL REVIEW THE CLADDING AND INSULATION SYSTEMS PROPOSED FOR THE PROJECT WITH RESPECT TO THEIR PERFORMANCE OVER WOOD STUDS WITH MOISTURE CONTENTS GREATER THAN 19�. EIFS SYSTEMS SHOULD BE AVOIDED ON WOOD -FRAMED PROJECTS DUE TO PROBLEMS WITH MOISTURE -PROOFING. PRESERVATIVE TREATMENT: WOOD MATERIALS ARE REQUIRED TO BE "TREATED WOOD" UNDER CERTAIN CONDITIONS IN ACCORDANCE WITH IBC SEC 2304.12 "PROTECTION AGAINST DECAY AND TERMITES." CONFORM TO THE APPROPRIATE STANDARDS OF THE AMERICAN WOOD -PRESERVERS ASSOCIATION (AWPA) FOR SAWN LUMBER, GLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES, AND MARINE PILES. FOLLOW AMERICAN LUMBER STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE MARK. METAL CONNECTORS/PT WOOD: ALL METAL HARDWARE AND FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE STAINLESS STEEL TYPE 316L. AT THE OWNER'S RISK AND DISCRETION, HOT -DIPPED GALVANIZED METAL HARDWARE AND FASTENERS MAY BE INVESTIGATED FOR USE IN LIEU OF STAINLESS STEEL PROVIDED THAT THE FINISH HAS A MINIMUM ZINC CONTENT OF AT LEAST 1.85 OZ./SF AND ITS USE IS COORDINATED BY THE CONTRACTOR AND WOOD SUPPLIER FOR THE EXPECTED ENVIRONMENT AND MOISTURE EXPOSURE FOR APPROPRIATE USE BASED ON THE METHOD OF PRESERVATIVE TREATMENT OF THE WOOD. STRUCTURAL INSPECTION SCHEDULE ITEM CI PI REFERENCE STANDARD REFERENCE REMARKS CONCRETE 1. INSPECT REINFORCEMENT AND VERIFY PLACEMENT. X ACI 318 CH 20, 25.2, 25.3, 1908.4 26.6.1-26.6.3 2. INSPECT ANCHORS CAST IN CONCRETE. X ACI 318: 17.8.2 1904.1, 3. VERIFY USE OF REQUIRED DESIGN MIX. X ACI 318: CH 19, 26.4.3, 26.4.4 1904.2, 1908.2, 1908.3 4. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR ASTM C172, ASTM C31, ACI 318: STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND X 26.4, 26.12 1908.10 DETERMINE THE TEMPERATURE OF THE CONCRETE. 5. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER 1908.6, APPLICATION TECHNIQUES. X ACI 318: 26.5 1908.7, 1908.8 SOILS 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO X ACHIEVE THE DESIGN BEARING CAPACITY. AS REQUIRED BY THE BUILDING OFFICIAL AND/OR GEOTECHNICAL REPORT 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. X SCHEDULE NOTES: 1. ITEMS MARKED WITH AN 'X' REQUIRE INSPECTION BY A SPECIAL INSPECTOR AS REQUIRED AND APPROVED BY THE BUILDING OFFICIAL. 2. CI: CONTINUOUS INSPECTION DURING PROGRESS OF WORK BY SPECIAL INSPECTOR. 3. PI: PERIODIC INSPECTION BY SPECIAL INSPECTOR AS REQUIRED FOR CONFORMANCE OF WORK. 4. TESTING AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE OWNER, BUILDING OFFICIAL, AND CONTRACTOR. See Top Vlew below for corresponding numbered steps. 10. On the front of rim, measure I -3/4" from the top and bottom and Install two 5" LedgerLOK screws through the rim board and Into ends of the two foists nearest to post location. (predrill using a 5/32" drill bit) 20 Place the post Into position and temporarily affix with a few screws or Halls. 30 Install full height 2x blocking behind the post and secure using four 5" LedgerLOKs -two screws through foists Into end of blocking, I - I /2" from top and bottom. @ From the front of the rim, Install two 8" ThruLOKs through the front rim Into the post and blocking. Stay 2- I /4" from top and bottome. 50 Add 12" piece of full height blocking on Inner faces of both foists to reinforce blocking behlnd post. Nall each using 12- I Od Halls evenly spaced. Top Vlew NOTE: FOR COMPLETE DESIGN VALUES AND ENGINEERING DATA, AVAILABLE THROUGH TECFINICAL BULLETIN "DECK RAIL POST TO RIM BOARD", AND ESR# 1078, AVAILABLE @ WWW. FASTENMASTER.COM nterlor Post - front I�Im At or Between JolStS front Vlew Side Vlew ThruLOK -Deck Rail Post Connection -Detail No. 1 6z v z O O � �^ O 3 N � � .. � ce N.. rn � O � rn ro O —� � 0 0 o a��'��t I�Wa��'�G'® �astenMaster �raming Details PRO Driven Rev. No Revision Descnption Date 0 first Release XX/XX/2020 STRUCTURAL ABBREVIATIONS & AND IF INSIDE FACE � AT IN INCH # NUMBER INT INTERIOR AB ANCHOR BOLT INV INVERT ABV ABOVE KIP, K 1,000 POUNDS ADD'L ADDITIONAL KSI KIPS PER SQUARE INCH ADJ ADJACENT LB POUND ALT ALTERNATE Ld DEVELOPMENT LENGTH APPROX APPROXIMATELY) LL LIVE LOAD ARCH ARCHITECTURAL) LLH LONG LEG HORIZONTAL ATR ALL -THREADED ROD LLV LONG LEG VERTICAL B/ BOTTOM OF LONGIT LONGITUDINAL BN BOUNDARY NAILING Ls LAP SPLICE LENGTH BLDG BUILDING LSL LAMINATED STRAND LUMBER BLKG BLOCKING LVL LAMINATED VENEER LUMBER BM BEAM MAX MAXIMUM BOTT BOTTOM OF MECH MECHANICAL BR BRACE MFR MANUFACTURER BRG BEARING MIN MINIMUM BTWN BETWEEN MISC MISCELLANEOUS C STANDARD CHANNEL MTL METAL CC CENTER TO CENTER (N) NEW CDF CONTROLLED DENSITY FILL NIC NOT IN CONTRACT CIP CAST IN PLACE NOM NOMINAL CJ CONSTRUCTION OR CONTROL JOINT NTE NOT TO EXCEED CJP COMPLETE JOINT PENETRATION NTS NOT TO SCALE CL CENTERLINE OC ON CENTER CLR CLEARANCE) OD OUTSIDE DIAMETER CMU CONCRETE MASONRY UNIT OPNG OPENING COL COLUMN OPP OPPOSITE CONC CONCRETE OSB ORIENTED STRAND BOARD CONN CONNECTION OWSJ OPEN WEB STEEL JOIST CONST CONSTRUCTION OWWJ OPEN WEB WOOD JOIST CONT CONTINUOUS PC PRECAST CTRD CENTERED PCF POUNDS PER CUBIC FOOT CTSK COUNTERSINK PL PLATE d PENNY (NAILS) PERP PERPENDICULAR DBL DOUBLE PLY PLYWOOD DEMO DEMOLITION PRE-MFR PRE -MANUFACTURED DET DETAIL PS PRESTRESSED DF DOUGLAS FIR PSI POUNDS PER SQUARE INCH DIA DIAMETER PSL PARALLEL STRANDED LUMBER DIAG DIAGONAL PT PRESSURE TREATED DL DEAD LOAD R RADIUS DN DOWN REF REFERENCE DP DEPTH REINF REINFORCING DWG(S) DRAWINGS) REQ'D REQUIRED DWL(S) DOWELS) RET RETAINING EA EACH RJ ROOF JOIST EF EACH FACE RT ROOF TRUSS EN EDGE NAILING REV REVISION EL ELEVATION SCHED SCHEDULE EMBED EMBEDMENT SECT SECTION ENGR ENGINEER SHTG SHEATHING EQ EQUAL(LY) SIM SIMILAR EW EACH WAY SOG SLAB ON GRADE EXIST, (E) EXISTING SPEC SPECIFICATION EXP EXPANSION SQ SQUARE EXT EXTERIOR SS STAINLESS STEEL FB FLAT BAR STD STANDARD FD FLOOR DRAIN STIFF STIFFENER FIN FINISH STL STEEL FJ FLOOR JOIST STRUCT STRUCTURAL FLR FLOOR SW SHEAR WALL FDN FOUNDATION SYM SYMMETRICAL FT FOOT, FEET T/ TOP OF FTG FOOTING T&B TOP AND BOTTOM GA GAUGE T&G TONGUE AND GROOVE GALV GALVANIZED THK THICK GB GRADE BEAM THRU THROUGH GEN GENERAL TJI TRUSS JOIST GEOTECH GEOTECHNICAL TOW TOP OF WALL GLB GLUE LAMINATED BEAM TRANSV TRANSVERSE GRTG GRATING TYP TYPICAL GT GIRDER TRUSS UNO UNLESS NOTED OTHERWISE HD HOEDOWN VERT VERTICAL HDR HEADER W WIDE FLANGE, WIDE HF HEM FIR W/ WITH HORIZ HORIZONTAL W/0 WITHOUT HSS HOLLOW STRUCTURAL SECTION WWF WELDED WIRE FABRIC HT HEIGHT X-STR EXTRA STRONG ID INSIDE DIAMETER XX-STR DOUBLE EXTRA STRONG z W Q N o LLJ LLI z z � � z = Q o z � � z � w J z LiJ z z � � o N w � � � '� � z O w w a 0 N Q W � � U 0 � W � Q � � � W w C� U � � Q � W � � Q � _ � � W � � I� W C�1 CHK BY: DRW BY: L2E L2E SCALE: AS SHOWN BAR = 1" FULL SIZE DATE: 2021.07.02 JOB N0: 20-060 w w SHEET: 2 OF 4 DWG N0: � � 0 � ��' I I �� , \� � � / PT 6X6 W/ BC6 CAP F1 F1 F1 F1 � & ABA66Z BASE, TYP FOUNDATION PLAN SCALE: 1 /4"=1 '-0" w cn w EXISTING RESIDENCE PREFAB SPIRAL STAIRCASE NIC EXIST Gf 0❑ 10'-5" 10'-43�„ DT D(1CT DCCJ DI AN _ 27'-0" LEGEND CONC SPREAD FTG CIP CONCRETE STEM WALL WALL SW# ADD/VERIFY SHEAR WALL INDICATOR (REF SHEAR WALL SCHED) HOEDOWN MARK (REF HOLD DOWN SCHED) /// ® POST �_y POST BELOW C HANGER PLAN NOTES 1. REFERENCE S100 SERIES FOR STRUCTURAL GENERAL NOTES, DRAWING LIST, ABBREVIATIONS, SPECIAL INSPECTION TABLES, ETC. 2. CONTRACTOR TO COORDINATE HOT TUB ELECTRICAL AND MECHANICAL DECK OPENINGS AND PENETRATIONS. 3. ALL WOOD IN CONTACT WITH WEATHER, EXPOSED CONCRETE, OR WITHIN 6" OF FINISHED GRADE SHALL BE PRESSURE -TREATED 4. USE HOT DIPPED GALVANIZED FASTENERS AND ZMAX HARDWARE AT CONNECTIONS TO PRESSURE TREATED LUMBER. 5. AT ALL BEARING AND SHEAR WALLS, REFERENCE STUD GRADE, SIZES AND SPACING PER PLANS AND GENERAL NOTES. 6. ALL METAL HARDWARE FOR EXTERIOR USE SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL. FOOTING SCHEDULE TYPE SIZE REINFORCING F1 2'-0"X2'-0"X1'-0" TH (4) �4 EW, BOTT 10'-4�" DECK &RAIL BEYOND, PICKETS NOT SHOWN FOR CLARITY +i °O � POSTS PER DETAIL 9/S300 COMPOSITE TIMBERTECH � RAIL W/ CAP — — I I p — � S I I I I I I I I I I I I I I +� o o PT POST PER PLAN RIM JOIST/FASCIA BEAM PER PLAN -III—III � � - �' III —III— � _III —III � �� -� � � III �= ELEVATION A -A SCALE: 1 /4"=1'-0" EXIST RESIDENCE ITS PER DETAIL �300 �EFAB SPIRAL -AIRCASE NIC EXIST GRADE z o W W z z Q � � z Q = Q o z � � z Q W z LLJ z � � z o N w � oho '� � � cn z 0 cn w z z o o �n � z � w w � � o 0 � cV Q O � N ��NN LOS �� of wasH� �&o `SF' �'C G v w `'PIh cll� '� '� '0� �, 48833 � �� �.� �'�ISTEae �w �SSIONAL E�Gl • �� Q � � C/� U 0 � W Z Q D O � � W �o 0 w w U � Q (./� � L�J Z �Q � _ � CHK BY: DRW BY: L2E L2E SCALE: AS SHOWN BAR = 1" FULL SIZE DATE: 2021.07.02 JOB N0: 20-060 SHEET: 3 OF 4 DWG NO:S 2 O O PLINTH AS REQ'D FOOTING PER PLAN (E) BOTTOM PLATE (E) WALL (E) FLOOR SHEATHING (E) FLOOR JOIST T ZT 1�Z 1Z (E) RIM BOARD (E) DOUBLE TOP PL JOIST H w cn w (E) WALL DETAIL 1 SCALE: 1 "=1'-0" POST FTG (E) HOUSE � (N) DECK 5 D ETAI L SCALE: 1 1 /2"=1 '-0" DECK JOIST PERP W/ (E) WALL POST PER PLAN POST BASE PER PLAN (E) TIES (E) HOUSE I (N) DECK '�W (2) z 1. 1'-6"X1'-6"X8" FOOTING MIN. � 2. 12"X10" MIN PLINTH DIMENSIONS, DEPTH AS REQ'D 11 N � � Jl (4) # 4 HOOKED DWL #4 u DRILI TG GROUT COMPACTED SUBGRADE DRILL & EP 4" MIN INTO ".,��, , �, DECKING PER ARCH DECK JOIST PER PLAN DTT1 Z TENSION TIES, INSTALL IN PAIRS PER PLAN, ELSE FASTEN TO NARROW FACE OF TOP PLATE W/ $"� LAG BOLT W/ 3"EMBED JOIST HANGER PER PLAN LEDGER PER PLAN NOTE: FLASHING PER CONTRACTOR NOTE: FASTENMASTER THRULOK CONTRACTOf DTT2Z. INSTALL PER MANUFACTURER'`. THRULOK DECK RAIL POST CONNECTI S1O1. RAILING /PICKET ASSEMBLY PER ARCH P.T. 4"X4" STANCHION, HF N0. 1 &BTR, @ 48" O.C. MAX, EXTEND THROUGH DECK SURFACE, SNUG AGAINST JOIST. WATERPROOFING PER ARCH DECKING FASCIA BOARD PER ARCH DTT2Z W/ �"� BOLT &WASHERS �"� BOLT &WASHERS RIM JOIST BEAM PER PLAN DETAIL g SCALE: 1 "=1'-0" RAILING W/ JOIST PERP TO BEAM (E) BOTTOM PLATE (E) WALL (E) FLOOR SHEATHING (E) FLOOR JOIST (E) RIM BOARD (E) DOUBLE TOP PL (E) WALL D ETAI L 2 SCALE: 1 "=1'-0" FTG @ (E) FDN (E) HOUSE � (N) DECK B/ FTG �) #4 T&I B, EA WAY �) #4 L DECKING PER ARCH DECK JOIST PER PLAN JOIST HANGER PER PLAN LEDGER PER PLAN NOTE: FLASHING PER CONTRACTOR 6 D ETAI L SCALE: 1 1 /2"=1 '-0" DECK JOIST PARALLEL W/ (E) WALL RAILING /PICKET ASSEMBLY PER ARCH P.T. 4"X4" STANCHION, HF N0. 1 &BTR, @ 48" O.C. MAX, EXTEND THROUGH DECK SURFACE, SNUG AGAINST JOIST. WATERPROOFING PER ARCH NOTCH DECKING AROUND POST FASCIA BOARD PER ARCH DTT2Z W/ �"� BOLT &WASHERS �"� BOLT &WASHERS BEAM WHERE OCCURS PER PLAN (2) BLOCKING, FASTEN BLOCKING TOGETHER W/ (12) 1Od X 3" JOIST PER PLAN (2) BLOCKING, FASTEN BLOCKING TOGETHER W/ (12) 1Od X 3" D ETAI L 1 0 SCALE: 1 "=1'-0" RAILING W/ JOIST PARALLEL TO BEAM CRIPPLE STUD B/ PLATE P.T. JOIST PER PLAN H 1 EA JOIST BEAM PER PLAN POST CAP PER PLAN POST PER PLAN D ETAI L 7 SCALE: 1 "=1 '-0" JOIST PERP TO BM (�l pnn� cu�nTurnir_ I LI\ JII\VVIVI\I"1L IVVILJ D ETAI L 1 1 SCALE: 1 "=1 '-0" TYP HEADER CONT FULL DEPTH BLOCKING @ MIDSPAN DECKING PER CONTRACTOR CONT FULL DEPTH BLOCKING E TOP PLATE PER GENERAL TURAL NOTES RAILING /PICKET ASSEMBLY PER CONTRACTOR, REFER 1/S3O1 FOR ADD'L CALLOUTS DECKING PER CONTRACTOR (2) 2X BLKG RIM JOIST �J FASCIA PER CONTRACTOR �,� III � � II II XI �� INI � III � � II II � � POST PER PLAN D ETA L 4 SCALE: 1 "=1'-0" DECK POST nrnvinln nrn nnnlTnnnTnn I VJI Vlll I LI\ I L.r\IV D ETAI L 8 SCALE: 1 "=1'-0" JOIST PERP TO OUTBOARD BM JOIST PER PLAN -BEAM PER PLAN -POST CAP PER PLAN FASCIA PER CONTRACTOR ;2) 2X BLKG RIM JOIST POST PER PLAN z W Q N o LLJ LEI z z � � z = Q o z � � z � w J z LLJ z z � � o N w � � � '� � z 0 w w a 0 N Q U 0 W � 00 (� � 0 � W W Q _ � U � W Q 0 W � Q C�1 CHK BY: DRW BY: L2E L2E SCALE: AS SHOWN BAR = 1" FULL SIZE DATE: 2021.07.02 JOB N0: 20-060 SHEET: 4 OF 4 DWG N0: ��oo