Loading...
REVIEWED BLD BLD2021-0723+Manufacturer_Specifications_and_Installation_Instructions+5.26.2021_11.38.14_AM+2217972REVIEWED BY CITY OF EDMONDS F911�Ti7fiF1 Single Stage Non -condensing FiredGas Furnace 100,000 BTU H S01 C100M5PSAA Note: Models may have a "T" in the 12th digit designating they meet California less than 40 ng/J (NOx) emissions requirements. RECEIVED May 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES/ DEPARTMENT Note: Graphics in this document are for representation only. Actual model may differ in appearance. TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. February 2019 1 100 5- -1 - ��IngersollRand m W _n O O Cal C W D m om xa-vu- 3-11/1{ S/a 1-S/a 24-I/A 5-3I4 AS TO OUR 9916 PLANS BENT Ur 19-11/1a 21.1116 nAecos a1TB OUTLET Boer up AIR FLUB OUTLET ' 1.1/5 pa T-31IS 20•i/6 3-❑/1{ 9 Ln t-1/2 -3/n -u na ILDT NONE IEEgNUIZ 1112pttAL RIBETI 05 c NET Q 1-vn OOiIBt GAS SUPPLY p p Ia0R120Rtl1 lOfil IALTSRYTBI ® ® 0i/n GAS �SU9ILT a ,M•Un6 ® ® BLDCIVICOL ® ® RIRBt ��1/n em m fAITBOGTDI IItXTR1Ul ® m VERB, ® asva eSUITSTAT O1/n ® ® 20•I /2 919BS TNBRNOSTAT ® IALTURATD1 VERBS qi RIS L-II16 - NOT USED ® tSIDS� 20-1I4 SIDE 1.7 ® ® I uaRETURN RETURN uaI° u•sra • ' /a ' - -6 IFI$AIR . 1 [ - - - a ® ® un6 I ruA In-sn{ --------- 1.13116 1 21-3115 nve un{ 1� wu IF WL 1.15n9 Ia-)II6 1•114 DOOR DOWN IUIT TAR {�---zaau xA, •a/• ® 3•I111{ 3.0119 INLET FLUB RNOCROUT 19-1/. AIR DWYrLON BELT TIa TTIa 20 as m N CD Q. e4 S n a rt �i< : G .; r MODEL S8BIC100M5PSAA TYPE Upflow / Horizontal / Downflow RATINGS (a) Input BTUH 100,000 Capacity BTUH (ICS) (b) (c) 80,000 Temp. Rise (Min. -Max.) 30 - 60 AFUE(%) 80 BLOWER DRIVE DIRECT Diameter— Width (In.) 11 X 11 No. Used 1 Speeds (No.) 9 CFM vs. in. w.g. See Fan Performance Table Motor HP 1 RPM 1075 Volts/Ph/Hz 120 / 1 / 60 FLA 10.9 COMBUSTION FAN — Type Centrifugal Drive — No. Speeds Direct- 1 Motor HP — RPM 3300 Volts/Ph/Hz 120 / 1 / 60 FLA 0.30 FILTER— Furnished? No Type recommended High Velocity High Vel. (No: Size-Thk.) 1— 20x25 — 1 in. VENT PIPE DIAMETER— Min (in.) (d) 4 Round MODEL S8B1C100M5PSAA HEATEXCHANGER Type Aluminized Steel Gauge (Fired) 20 ORIFICES — Main Nat. Gas Qty. — Drill Size 5 - 45 GAS VALVE Redundant- Single Stage PILOT SAFETY DEVICE Type 120 V SIM Igniter BURNERS — QTY 5 POWER CONN. — V/Ph/Hz (e) 120 / 1 / 60 Ampacity (Amps) 14.1 Max. Overcurrent Protection (Amps) 15 PIPE CONN, SIZE (in.) 1/2 DIMENSIONS Uncrated (In.) 34 x 21 x 28.75 Crated (In.) 35.5 x 23 x 30.87 WEIGHT Shipping (Lbs.) / Net (Lbs.) 144 / 136 (a) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. (b) Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 — latest edition. (c) Based on U.S. government standard tests. (d) Refer to the Installer's Guide. (e) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. S8B1 C100M5-SUB-1 A -EN Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 918 438 — — — 2 1183 950 716 483 249 3 1709 1546 1383 1220 1057 4 1771 1676 1581 1486 1391 S8B1C100M5PSAA 5 1931 1793 1656 1518 1380 6 2028 1898 1768 1638 1508 7 2177 2057 1938 1818 1699 8 2351 2246 2141 2036 1931 9 2609 2522 2434 2347 2260 S8B1 C100M 5-SUB-1 A -EN NATURAL GAS MODELS Central Heating furnace designs are certified by Intertek for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge tubular aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a discharge of gas fumes to the outside. BURNERS Multiport, Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. ENERGY EFFICIENT OPERATION Air-TiteT61 cabinet design is certified to <1% air leakage per ASHRAE 193 "Method of Test for Determining the Airtightness of HVAC Equipment." AIR DELIVERY The 9 speed constant torque blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. STYLING Heavy gauge steel and "wrap -around" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S8B1C100M5-SUB-1A-EN 5 80% AFUE on S8131 FURNACE MODELS Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter, easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high -efficiency coils No knockouts 4—WAY MULTI -POISE 9 SKU's — Upflow/ Downflow / Horizontal Left / Horizontal Right Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H2O external static pressure REGULATORY All models are airtight; 1% or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34" high open vestibule for ease of installation and service DIMENSIONS Widths are industry standard: 14.5", 17.5", 21 ", and 24.5" Depth remains approximately 28" Cabinet is compatible with industry standard coils, as well as, other accessories INTEGRATED FURNACE CONTROL Setup / Status / Diagnostics / Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR ALUMINIZED STEEL HEAT EXCHANGER VORTICA II BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable, easy to clean, housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise FOUR—WAY MULTI -POISE (UPFLOW, DOWNFLOW, HORIZONTAL LEFT AND RIGHT) Easier to specify Shipped ready to install (no conversion kits required) Every model has at least two venting options 6 SM C100M5-SUB-1 A -EN • ', 9 8, Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands —including Club Car), Ingersoll Rand), Thermo King® and Trane)—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. Ingersoll Rand. NO. THERMO KIN rJMME' ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S8B1C100M5-SUB-1A-EN 15Feb2019 Supersedes (New) ©2019 Ingersoll Rand