PROJECT INFORMATION
SITE ADDRESS: 9649 FIRDALE AVE., EDMONDS, WA 98020
PARCEL NUMBER: 00449900000100
LEGAL DESCRIPTION: Section 36 Township 27 Range 03 Quarter SE - FORSHEES FIRDALE
VILLAGE BLK 000 D-00 - COMB FOR TAX PURP ONLY - LOT 1 PLUS PTN VAC
CUL-DE-SAC TGW LOTS 2-3 PLUS ADJ PTN VAC CUL-DE-SAC LESS PTN
WHNFORSHEE FIRDALE VILLAGE 5 ALSO LESS TH PTN LOT 3DAF - BEG AT
Approved
by Fire
NECDR OF THN8/20FSW1/4SE1/4THS 1*42 NTN89WALGELN OF 4.06FT WI/4
SE1/4 510FT TH N88*26 50W 75FT TPBTH CONT N88*26 50W 104.06FT
THS72*21 54E 108.30FT TH N01*33 10E 30FT TPB TGW LOT 4 PLUS ADJ PTN
VAC CUL-DE-SAC LESS PTN WHIN FORSHEE FIRDALE VILLAGE 5 TGW LOT 5
09/21 /2021 AFM
/--/F�tterer
PLUS PTN VAC CUL-DE-SAC & LESS PTN PROP PLAT FORSHEES
FIRDALEVILLAGE NO 5 TGW LOT 12 TGW LOT 13 & NWLY 8FT LOT 14 TGW
SELY 52FT LOT 14
APPLICANT:
QUAN NGUYEN
TAO MOVEMENT (HOLISTIC HEALTH CENTER)
CODE/ZONING INFORMATION
S -.-SW I NW-205TH ST.
NOTE:
THIS SITE PLAN IS PREAPARED WITHOUT THE BENEFIT OF A SURVEY. INFORMATION WAS COLLECTED FROM LAND OWNER, SNOHOMISH COUNTY GIS, AERIAL PHOTOGRAPH AND SITE OBSERVATIONS.
IT IS NOT INTENDED FOR ANY CONSTRUCTION RELATED DOCUMENTATION BUT RATHER AS A REPSRESENTATION OF WHAT IS PRESENT ON SITE.
GOVERNING BUILDING CODE:
2018 INTERNATIONAL BUILDING CODE & APPENDIX E
2018 INTERNATIONAL EXISTING BUILDING CODE
LOT AREA:
3.12 ACRES (ENTIRE SITE)
ZONING:
FVMU (FIRDALE VILLAGE MIXED USE)
PERMIT APPLYING FOR:
CHANGE OF USE FOR UNIT 9649 FROM RETAIL (M))(MATTRESS
STORE) TO BUSINESS PROFESSIONAL SERVICE (B) (HOLISTIC
HEALTH CENTER)
TYPE OF CONSTRUCTION:
VB
OCCUPANY FOR BUILDING:
RETAIL/ COMMERCIAL (B/ M)
SPACE (9649) IS NON-SPRINKLERED
BUT DOES HAVE A FIRE ALARM SYSTEM
TOTAL SQUARE FOOTAGE OF SPACE 9649: 1,133 SQ. FT.
NUMBER OF EMPLOYES:
2
OCCUPANT LOAD :
SEE FLOOR PLAN
BRIEF DESCRIPTION OF BUSINESS:
PROVIDE PERSONAL TRAINING TO CLIENTS TO HELP THEM
ACHIEVE THIER OWN PERSONAL HEALTH, FITNESS, WEIGHT
LOSS AND LIFESTYLE GOALS.
THIS PROJECT UTILIZED PRESCRIPTIVE COMPLIANE METHOD (CHAPTER 5) OF IEBC.
ENGINEERING DIVISION
APPROVED AS NOTED
yf �9/21/2021
ALL INTERIOR WORK. NO
NEW IMPERVIOUS AREA.
APPROVED
PLANS MUST BE
ON JOB SITE
APPROVED BY PLANNING
Sep 13 2021
City Of Edmonds
Building Department
----------- ----------------
Work CHANGE OF USE
------------------
-----------------------------------
Address; 9617 FIRDALE AVE #9469
----------------------------------------
-----------------------------------------
Owner : TAO MOVEMENT
-------------------------------
Approved Date; 09/17/2021
Building Official: Eri-& Co**,r
'-----------------------------------
BLD2021-1163
Permit Number:
CONSTRUCTION TYPE VB
OCCUPANCY GROUP B
OCCUPANT LOAD 8
RECEIVED
Aug 30 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SURFACE
MOUNTED
FLUROESCENT
FIXTURES (TYP.)
SURFACE
MOUNTED
TEXTURED
CEILING PANELS
(TYP.)
SURFACE
MOUNTED HVAC
DUCT (TYP.)
FIRE ALARM
(TYP.)
REFLECTIVE CEILING PLAN
SCALE: 1/8" = V-0"
MECHANICAL WATER
EQUIPMENT HEATER/
COMM EQUIP.
1 I L
BATHROOM
I I
MECH. CORRIDOR L-- 4
OFFICE
I I
I
LC J-i
Lj
♦
♦
♦ �1Cll
♦
♦
EXERCISE AREA
♦
♦
♦
I
I
FLOOR PLAN
SCALE: 1/8" = 1'-0"
SURFACE MOUNTED
ELECTRICAL PANEL
Entry door and
components to
comply with
IBC1010.1.9.3.
PROJECT INFORMATION
SITE ADDRESS:
9649 FIRDALE AVE., EDMONDS, WA 98020
PARCEL NUMBER:
00449900000100
LEGAL DESCRIPTION:
Section 36 Township 27 Range 03 Quarter SE - FORSHEES FIRDALE
VILLAGE BLK 000 D-00 - COMB FOR TAX PURP ONLY - LOT 1 PLUS PTN VAC
CUL-DE-SAC TGW LOTS 2-3 PLUS ADJ PTN VAC CUL-DE-SAC LESS PTN
WHNFORSHEE FIRDALE VILLAGE 5 ALSO LESS TH PTN LOT 3DAF - BEG AT
NE COR OF S1/2 N1/2 OF SW1/4 SE1/4 TH S01*42 29W ALG E LN OF SD SW1/4
SE1A 51OFT TH N88*26 50W 75FT TPBTH CONT N88*26 50W 104.06FT
THS72*21 54E 108.30FT TH N01*33 10E 30FT TPB TGW LOT 4 PLUS ADJ PTN
VAC CUL-DE-SAC LESS PTN WHN FORSHEE FIRDALE VILLAGE 5 TGW LOT 5
PLUS PTN VAC CUL-DE-SAC & LESS PTN PROP PLAT FORSHEES
FIRDALEVILLAGE NO 5 TGW LOT 12 TGW LOT 13 & NWLY 8FT LOT 14 TGW
SELY 52FT LOT 14
APPLICANT:
QUAN NGUYEN
TAO MOVEMENT (HOLISTIC HEALTH CENTER)
FIRE
EXTINGUISHER
OCCUPANCY LOAD CALCULATIONS (Der table 1004.5
EXERCISE AREA: 826.5/50
= 5
OFFICE: 187/150
= 2
MECH./RESTROOM/ CORRIDOR: 119.6/300
= 1
TOTAL OCCUPANT LOAD:
= 8 <50, 1 EXIT IS SUFFICIENT
- EXIT TRAVEL DISTANCE PER TABLE 1016.1
= 53'-4" <200'
RECEIVED
Aug 30 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
2015 Washinaton State Enerav Code Compliance Forms for Commercial Buildinas includina R2. R3. R4 over 3 stories and all R1 Revised Nov 2017
Project Info
Project Title: Tao Movement change of use permit
Date 3/22/2021
Compliance
Applicant Information. Provide contact information for individual who can
For Building Department Use
forms do not
respond to inquiries about compliance form information provided.
require a
password to
Company Name: Tao Movement
Company Address: 9649 Firdale Ave., Edmonds, WA 98020
use.
Instructional and
Applicant Name: Quan Nguyen
calculating cells
are write -
protected.
Applicant Phone: 206-734-0525
Applicant Email: taomovement@outlook.com
Project Description
❑ New Building ❑ Addition El Alteration 0 No Lighting Scope
Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms.
Interior Lighting System
Existing mix of incandescent and fluorescent fixtures
Description
0 Interior Lighting Plans Included
Interior Lighting Power
❑ Building Area Method 0 Space -by -space Method
Allowance Method
Select method used in project.
Interior Lighting Controls
❑ All C405.2.1 - C405.2.8 Lighting Controls ❑ C405.2 Exception 5 Luminaire Level
Lighting Controls (LLLC)
❑ Additional Efficiency Package Option
C406.4 Enhanced Digital Lighting Controls
To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the
required controls per C406.4.
Dwelling Unit Interior
Permanently installed interior lighting fixtures in dwelling units comply with: No Dwelling
Lighting
O C405.2 thru C405.5 Commercial Lighting Controls and LPA Units
0 C406.3 High Efficacy Lighting
R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential
provisions in lieu of WSEC Commercial provisions.
Exterior Lighting System
unknown
Description
0 Exterior Lighting Plans Included
Building Additions
Compliance Method
Interior lighting
Exterior lighting
Lighting systems in addition area comply with all applicable
❑
❑
provisions as a stand alone new construction project
Refer to Section C502.2.6 for additional
requirements.
Lighting systems in addition are combined with existing
❑
❑
building lighting systems to demonstrate compliance
Addition is combined with existing:
For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in
Proposed Lighting Wattage table in LTG-INT-BLD or L TG-INT-SPA CE form.
For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in
Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form.
2015 Washington State Energy Code Compliance Forms for Commercial Buildings includinq R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title: Tao Movement change of use permit Date 3/22/2021
Change of Space Use
❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to
comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2).
Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in
LTG-INT-BLD or L TG-INT-SPA CE form.
Interior and Exterior
Lighting Power
Interior lighting
Parking garage
Exterior lighting
50% or more of existing are replaced
❑
❑
❑
Lighting Alterations
Select all Lighting Power and Lighting
Control elements that apply to the scope
Less than 50% of existing are replaced
❑
❑
❑
of the retrofit project. If project includes a
combination of spaces where less than
50% of the existing fixtures are replaced
Lamp and/or ballast replacement only —
existing total wattage not increased
❑
❑
❑
in some spaces, and 50% or more of the
fixtures are replaced in others, then
provide separate lighting power
compliance forms for the two retrofit
conditions. Spaces undergoing the same
type of retrofit may be combined into one
lighting power compliance form.
50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total
LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed
Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the
total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting
Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
50% threshold applies to number of luminaires for interior spaces and parking garages, and total
Refer to Section C503.6 for additional
installed wattage for exterior luminaires.
requirements.
Lighting Controls
Interior lighting
Parking garage
Exterior lighting
All alteration lighting controls shall be
commissioned per C408.3.
New wiring installed to serve added
fixtures and/or fixtures relocated to new
circuit(s)
New or moved lighting panel
❑
❑
❑
Interior space is reconfigured -
❑
luminaires unchanged or relocated only
New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy
❑� No changes are being made to
the interior or exterior lighting
systems and existing space
sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting
controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7.
New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic
time switch controls per C405.2.2.
uses and configuration are not
Reconfigured interior space - Provide all required lighting controls that apply to a new interior space.
changed.
Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces.