APPROVED BLD BLD2021-1583+Plumbing_Plan+11.21.2021_12.01.31_PM+2531702PLUMBING GENERAL ABBREVIATION
ABBV
FULL NAME
ABBV
FULL NAME
ABBV
FULL NAME
AAV
AIR ADMITTANCE VALVE
DN
DOWN
NTS
NOT TO SCALE
ABV
ABOVE
DS
DOWNSPOUT
OFD
OVER FLOW DRAIN
AFF
ABOVE FINISHED FLOOR
DWG
DRAWING
POC
POINT OF CONNECTION
AP
ACCESS PANEL
E
EXISTING
PRV
PRESSURE REDUCING VALVE
BEL
BELOW
ELEV
ELEVATION
PVC
POLYVINYL CHLORIDE
BFP
BACKFLOW PREVENTER
ET
EXPANSION TANK
RD
ROOF DRAIN
BOP
BOTTOM OF PIPE
EWH
ELECTRIC WATER HEATER
RPBA
REDUCED PRESSURE BACKFLOW ASSY
BV
BALL VALVE
F
FIRE
TOG
TOP OF GRATE
BWV
BACK WATER VALVE
FCO
FLOOR CLEAN OUT
UG
UNDER GROUND
CB
CATCH BASIN
FD
FLOOR DRAIN
LINO
UNLESS NOTED OTHERWISE
CFF
CAP FOR FUTURE
FU
FIXTURE UNIT
VTR
VENT THRU ROOF
CI
CAST IRON
GI
GREASE INTERCEPTOR
W/
WITH
CL
CENTER LINE
GPM
GALLONS PER MINUTE
WCO
WALL CLEAN OUT
CO
CLEAN OUT
GWH
GAS WATER HEATER
WH
WALL HYDRANT
CPVC
CPVC MATERIAL
HB
HOSE BIBB
WHA
WATER HAMMER ARRESTOR
DCBP
DOUBLE CHECK BACKFLOW PREVENTER
HP
HIGH PRESSURE
WM
WATER METER
DCVA
DOUBLE CHECK VALVE ASSEMBLY
IE
INVERT ELEVATION
YH
YARD HYDRANT
DEMO
DEMOLISH
MH
MANHOLE
DFU
DRAINAGE FIXTURE UNIT
NIC
NOT IN CONTRACT
DESCRIPTION
BALANCING VALVE
GATE VALVE
GLOBE VALVE
BALL VALVE - FULL PORTED
SILENT CHECK VALVE
REDUCED PRESS. BACKFLOW PREVENTER
BACKFLOW PREVENTER
UNION
STRAINER
PRESSURE RELIEF VALVE
PRESSURE REDUCING VALVE
PRESSURE / TEMPERATURE PORT
PRESSURE GAUGE
SOLENOID VALVE
PIPE - HEAT TRACE
HOSE BIB
SUB -METER WATER FLOW
WATER HAMMER ARRESTOR
FLEX PIPE
VENT THROUGH ROOF
FLOOR CLEANOUT
WALL CLEANOUT
FLOOR DRAINS
FLOOR SINKS
ROOF, OVERFLOW, AND COMBINATION DRAINS
PLUMBING SYMBOL LEGEND
ABBV
SYMBOL
DESCRIPTION
BALV
GAS COCK
GV
VERTICAL EXPANSION TANK
GLV
T
TEMPERATURE GAUGE
BV
Q
THERMOMETER
CV
D°4,
BALL VALVE W/ 3/4" HOSE ADAPTOR
RPBP
p
CONCENTRIC REDUCER
BFP
TWO-WAY CONTROL VAVLE
UNION
THREE-WAY CONTROL VALVE
STRN
POINT OF CONNECTION
PTV
PIPE BREAK - PIG TAIL
PRV
6• CHWS
PIPE - SIZE & ABBREVIATION
P/T
6" CHW
PIPE - SIZE & ABBREVIATION WITH INSULATION
PG
®
PUMP CIRCULATION
SV
ROOF DRAIN (RISER)
HB
MTR
WHA
VTR
V� OVER -FLOW DRAIN (RISER)
FrN 60' OFFSET FOR SUDS
'ITTATT
FLTR-1
WC-1
1/2% SLOPE
1%SLOPE
2%SLOPE
�
EXPANSION THERMAL
DOMESTIC PEX MANIFOLD
PLUMBING TRAP
PLUMBING FIXTURE N.I.C. TAG
PLUMBING FIXTURE TAG
PLUMBING EQUIPMENT TAG
1/16" PER FOOT PIPE SLOPE
1/8" PER FOOT PIPE SLOPE
1/4" PER FOOT PIPE SLOPE (TYP. UNO)
ABBV
GC
VET
TG
THERM
BV W/ HA
CR
2WAY
3WAY
P.O.C.
RD
OD
60° OFST
EXP
MFLD
TRAP
PLUMBING SYSTEM LEGEND I=
a
LINE TYPE
FULL NAME
ABBR
LINE TYPE
FULL NAME
ABBR
DOMESTIC WATER
— — —
DOMESTIC COLD WATER
DCW
GD
GARAGE DRAIN
GD
— PDCW —
DOMESTIC COLD WATER - HIGH PRESS
DCW-HP
GD
GARAGE DRAIN (UNDERGROUND)
GD
— DFw —
DOMESTIC FILTERED WATER
DFW
GW
GREASE WASTE
GW
- -
DOMESTIC HOT WATER
DHW
— — GwuG —
—
GREASE WASTE (UNDERGROUND)
GW
— — — NPTW — —
DOMESTIC HOT WATER 140
DHW 140
iW
INDIRECT WASTE
IW
— — NPCw — —
DOMESTIC HOT WATER 160
DHW 160
— PSS —
—
PUMPED SANITARY SEWER
PSS
— — DHW — —
DOMESTIC HOT WATER - HIGH PRESSURE
HW-HP
PW
PUMPED WASTE
PW
— — — — — — — — — — — —
— DOMESTIC HOT WATER CIRC
DHWC —
— — — — — — — — — — — —
— —
VENT
V
— — — — — NPTWC — — — —
— DOMESTIC HOT WATER CIRC 140
DHWC 140
WASTE
W
— — — — — SPC — — — —
— DOMESTIC HOT WATER CIRC 160
DHWC 160
— SS —
SANITARY SEWER
SS
— — — — — DHWC — — — —
— DOMESTIC HOT WATER CIRC - HIGH PRESS
DHWC-HP
ow-
— — DTW — —
DOMESTIC TEMPERED WATER
DTW
— — FTDR —
—
FOOTING DRAIN
FTDR
— — — — — DTWC — — — —
— DOMESTIC TEMPERED WATER CIRC
DTWC
ORL
OVERFLOW RAIN LEADER
ORL
MEDICAL & LAB GASSES
RL
RAIN LEADER
RL
AR
ARGON
AR
PSD
PUMPED STORM DRAIN
PSD
CO2
CARBON DIOXIDE
CO2
—
— — SD — —
—
STORM DRAIN
SD
HE
HELIUM
HE
/A
INSTRUMENT AIR
IA
IA -IN
INSTRUMENT AIR INTAKE
IA -IN
LA
LAB AIR
LA
MA
MEDICAL AIR
MA
MVAC
MEDICAL VACUUM
MVAC
MVAC-E
MEDICAL VACUUM EXHAUST
MVAC-E
N2
NITROGEN
N2
N20
NITROUS OXIDE
N20
02
OXYGEN
02
VW
VACUUM
VAC
WAGD
WASTE ANESTHETIC GAS DISPOSAL
WAGD
WAGD-E
WASTE ANESTHETIC GAS DISPOSAL EXH
WAGD-E
MEDICAL EQUIPMENT SCHEDULE
NO. EQUIPMENT DESCRIPTION
0-1 OXYGEN WALL OUTLET - CHEMETRON - PATTONS MEDICAL 01 SERIES 01-CHWAL-OXY-N, SAFETY KEYED OUTLET FOR CHEMETRON TYPE CONNECTION, US COLOR CODED FOR OXYGEN, 1/21, OD
(QTY 2) CONNECTION CLEANED FOR OXYGEN SERVICE, W/ CYCOLOY TYPE FACE PLATE SEPARATE FROM THE PRIMARY VALVE WITH GAS CHECK. (VERIFY CONNECTION TYPE BEFORE ORDERING.)
N-1 N20 WALL OUTLET - CHEMETRON - PATTONS MEDICAL 01 SERIES 01-CHWAL-N20-N, SAFETY KEYED OUTLET FOR CHEMETRON TYPE CONNECTION, US COLOR CODED FOR NITROUS OXIDE, 1/2" OD
(QTY 1) CONNECTION CLEANED FOR OXYGEN SERVICE, W/ CYCOLOY TYPE FACE PLATE SEPARATE FROM THE PRIMARY VALVE WITH GAS CHECK. (VERIFY CONNECTION TYPE BEFORE ORDERING.)
W-1 WAGD WALL OUTLET - CHEMETRON - PATTONS MEDICAL 01 SERIES 01-CHWAL-WAG-N, SAFETY KEYED OUTLET FOR CHEMETRON TYPE CONNECTION, US COLOR CODED FOR WAGD, 112" OD
(QTY 1) CONNECTION CLEANED FOR OXYGEN SERVICE, W/ CYCOLOY TYPE FACE PLATE SEPARATE FROM THE PRIMARY VALVE WITH GAS CHECK. (VERIFY CONNECTION TYPE BEFORE ORDERING.)
V-1 VACUUM WALL OUTLET - CHEMETRON - PATTONS MEDICAL 01 SERIES 01-CHWAL-VAC-N, SAFETY KEYED OUTLET FOR CHEMETRON TYPE CONNECTION, US COLOR CODED FOR VACUUM, 1/2" OD
(QTY 5) CONNECTION, W/ CYCOLOY TYPE FACE PLATE SEPARATE FROM THE PRIMARY VALVE WITH GAS CHECK. (VERIFY CONNECTION TYPE BEFORE ORDERING.)
VS-1 VACUUM WALL SLIDE - CHEMETRON - PATTONS MEDICAL 01 SERIES 01-WALSLIDE-N, SLIDE BRACKET FOR CHEMETRON VACUUM OUTLET, W/ ALUMINUM SLIDE, AND CYCOLOY COVER PLATE.
(QTY 5)
MED GAS PIPING MATERIAL SCHEDULE
PIPING MATERIAL SCHEDULE:
LOCATION PIPING SIZE MATERIAL (FOOTNOTE) JOINT
MEDICAL OXYGEN GAS, CARBON DIOXIDE GAS, ALL ASTM B 819 COPPER TYPE L FOOTNOTE (a)
NITROUS OXIDE GAS
ABOVE GROUND MEDICAL VACUUM ALL ASTM B 819 COPPER TYPE L FOOTNOTE (a)
WASTE ANESTHETIC GAS DISPOSAL (WAGD) ALL ASTM B 819 COPPER TYPE L FOOTNOTE (a)
FOOTNOTES:
(a) MEDICAL GAS PIPING, FITTINGS, AND VALVES SHALL BE CLEANED, PROTECTED AND LISTED FOR OXYGEN SERVICE. ALL JOINTS SHALL BE BRAZED USING ANSI/AWS A5.8
COPPER -PHOSPHORUS OR COPPER -PHOSPHORUS -SILVER BRAZING FILLER METAL WITHOUT FLUX. JOINTS SHALL BE PURGED WITH OIL -FREE DRY NITROGEN NF DURING
BRAZING AND TESTING IN ACCORDANCE WITH NFPA 99.
MED GAS PIPING GENERAL NOTES
1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. COORDINATE WITH OTHER TRADES AND CONFIRM ALL CLEARANCES BEFORE
COMMENCING WORK.
2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITION OF NFPA 99 HEALTH CARE FACILITIES CODE AND 2018 EDITION OF THE UNIFORM PLUMBING CODE AS
AMENDED BY THE STATE OF WASHINGTON.
3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS.
4. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2012 EDITION OF THE NFPA 99, 5.1.10.11.4 & TABLE 5.1.10.11.4.5
5. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL.
6. PROVIDE EARTHQUAKE RESTRAINT FOR PLUMBING PIPING AND EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2018 IBC AND ASCE 7.
MED GAS SCOPE OF WORK
DEMO CEILING MOUNTED 02 (2), VAC (1) AND N20 (1) OUTLETS AND ASSOCIATED PIPING.
INSTALL NEW WALL MOUNTED 02 (2), VAC (5), N20 (1) AND WAGD (1) OUTLETS AND ASSOCIATED PIPING
PROVIDE MEDICAL GAS/VACUUM SYSTEM TESTING & CERTIFICATION IN ACCORDANCE WITH NFPA 99.
LEGAL DESCRIPTION
PARCEL NUMBER: 00580700002500
LEGAL DESCRIPTION: SOLNERS 5 ACRE TRACTS BLK 000 D-00 - N 1/2 OF TRS 27 & 28 & S 1/2 OF TRS 25 & 26 TGW TH PTN OF VAC 10TH ST SE (FORMERLY 216TH ST SW ADJ THRTO) & TGW TH PTN OF TR 29 SD
PLAT LY WILY OF FDL - COM AT NWCOR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESC TH SLY TAP 35.44FT FIR SW CR OF SD TR 29 AS MEAS ALG S BDY SD TR & TERM OF LN HEREIN DESC (PER
CITY EDM BLA REC AF NO 199909155005)
CONTACT LIST
TITLE
NAME
COMPANY
PHONE NUMBER
EMAIL
PROJECT ENGINEER
KIM LARSEN
MACDONALD MILLER
206-768-4116
KIM.LARSEN@MACMILLER.COM
PROJECT ENGINEER
JORDAN CROWE
MACDONALD MILLER
206-768-3836
JORDAN.CROWE@MACMILLER.COM
PROJECT MANAGER
JAKE BURSTEIN
MACDONALD MILLER
206-255-6723
JAKE.BURSTEIN@MACMILLER.COM I
PLUMBING FOREMAN
FRANK TINNIN
MACDONALD MILLER
206-571-9813
FRANK.TINNIN@MACMILLER.COM
APPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
Approved by Fire
11/30/2021 AFM /CFtttere►-
I— - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - —
Provide Med Gas testing reports to the
I
City Inspector at the time of inspection.
------------------------------------------------------------
I
i
I
i
City Of Edmonds
Building Department
Work PLUMBING- MED GAS
Address 21601 76TH AVE W
Owner SWEDISH HOSP- SURGICL CENTER
-------------------------------
Approved Date ; 12/07/2021
Building Official Eri,& Cv fe r
Permit Number BLD2021-1583
215th St SW
SITE
<
o=
216th St SW
216th St SW
218th S
SW
a
Iv
r
r-
220th St SW
o(y)
�
U)
�,
z
a�
�
�
_
O
MM
W
6 04
E U)
o LL
co
U^) _
L
0J
O
C)
0
U)
U)0Q o
E�
0
>
U
'
°o
U_
J
Q
� N
j
LI
� o
11 /19/2021
z
O
U)
W
I"
RECEIVED
Nov 21 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
U)
(Q
V
0
U-1
G
U)
Oz
cf)
U)O
0
2
z
0
C)
Ow
N
w
2i�
J
C)
0
>Q
Q =
L1J
w
U
I-_
r_z
=
>
U
�r�
V!
_�
vJ CV LULU
vJ
0000
ENGINEER:
LAST REVISED:
K LARSEN
11-19-21
CHECKED
BY:
DATE PLOTTED:
D JACQUES
11-19-21
CAD:
ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212273-00
SHEET NUMBER:
TPO.01
z
O
U
U)
z
O
U
Of
O
LL
0
LU
7)
W
C)
O
z
a
E
a�
0
z
T
LL
VICINITY MAP
N NO SCALE
7 8
\ 2" C.W %" HW.
2" W UP H.W.C. 4" DN
2" V. UP
2"WUP
�v
GAS TRACK
(2) 02 & VAC
(1) N20
1%" W. OF
1%" V. UP
14
2" V
L
2"W4"H&
CW UP
CLG. OUTLETS
(2) 02 & VAC (1) N20
CLG. OUTLETS
(2) 02 & VAC (1) N20
ME
VAC
1%" V. DN
')2"VUP
VAC
O
O
VAC
" W QPF—
%4" HW. & 1" C.W.
08
2" V
WASHER
O
0 STERILIZER
O %" CW 2" FUN
O DR & 4" STM
__V
0
s4"H&CW
1%" FFD ROUGH
IN & CONN.
SONIC
CLEANER
rl
- r —
I
—STERILIZER- PROVIDE —
1%" FUN. DR%" CW
%4' STM SUPPLY &
RET.
I(E) 1 1/4"MVAC
Y4" H & C.W. & lY2" W.
2" V. DN
IN
/EY R
AFT
�/2" V DN
F-2
//—STERILI;
PROVIDI
DRAIN, i
I
I
I
I
I
I
I
I
I
I
9 10
3" FLUSHING
F L R, DR,
SEE NOTE 1.
FLUSH VALVE
SEE NOTE 2.
ACCESS PANEL
2" V. UP
I
I
1' C.W. &1" R.W. UP
I
I
I
2 1
I
I
I
I
AREA OF WORK
I
I
I
I
I
I
J
rVl/7
�
O Il-
OD EoD
7
Q I� C:)
O
O00L
TT
VJ
+� C'4 E U)
D
cp N O O
U) LL
J
N Q
c
O
i .gC)
U) o cu
E�
' o
Q��Z
Q
'
U
O O U
N J
Q
LL
�o
11 /19/2021
I I I I I I I I
LLI
a
0
0
z
O
Lu
I I I I I I I I w
a
0
z
O
Ln
Lu
RECEIVED
Nov 21 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
Cn J
Z
Q 0- O
CD O
M 75 U
W W D
0
C� J z
Q O
O z I— C/) U
U)O 0
02 Q� O
z0 D r LL
Ow N o
y 00cy) Z w
O�;Q W�
�. LJ c�
U ti Z (n 2 Q� O
C� U) N_lulJ m dg:t— Z
ENGINEER: LAST REVISED:
K LARSEN 11-19-21
CHECKED BY: DATE PLOTTED:
D JACQUES 11-19-21
CAD: ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212273-00
SHEET NUMBER:
DP1 .01
z
1 /4" = 1'-0"
m
3
a
0
a
N
N
r
n
W
0
0
w
U
U)
a
E
a
w
U
y
c+�
n
N
D1
N
n
n
7 8 9
2" W UP � H.W.C. 4" DN
2" V. UP
2"WUP
�v
GAS TRACK
(2) 02 & VAC
(1) N20
12" W. OF
12" V. UP
14
2" V
L
2"W4"H&
CW UP
CLG. OUTLETS
(2) 02 & VAC (1) N20
CLG. OUTLETS
(2) 02 & VAC (1) N20
ME
VAC
12" V. DN
)2"VUP
VAC
O
O
VAC
" W QPF—
%a" HW. & 1" C.W.
13
08
2" V
O WASHER
OSTERILIZER
O 2" CW 2" FUN
O DR & 4" STM
�EK
s4"H&CW
12" FFD ROUGH
IN & CONN.
SONIC
CLEANER
- r r -
I
-STERILIZER- PROVIDE —
12" FUN. DR2" CW
%4' STM SUPPLY &
RET.
I(E) 1 1/4"MVAC
s4"H&C.W.&lY2"W
2" V. DN
IN
/EY R
AFT
�/2" V DN
F-2
�STERILI;
PROVIDI
DRAIN, i
I
I
I
I
I
I
I
I
I
I
U
>
VAC
2" V DN.
4" H& CW DN.
10
U z VV ur I
07 2 DN. t
2" V UP I
I I
REFER TO ARCHITECTURAL
ELEVATIONS FORE ACT FIRE HOSE I
VAC PLACEMENT OF MEDICAL
CAB' 2 V
GAS WALL INLETS/OUTLETS
I I
N 1 I 1/2"N20 DROP 1" H & CW DN I
VS 1 V 1 3/4"VAC 12" V. DN I
2 V. DN 1 1 /2"DROP02 4" H& CW
0 VAC I I
_ DROP 12" V. DN� -
D VAC
U
>
MVAC WALL
OUTLET
VAC
LO POC TO (E) (E) 1 1/4"MVAC z I I
1 1 /4"MVAC I
O I
z .,
I I
I I
(E) 1 1/4"MVAC I
(E) MVAC
I
ZVB I I
02 & N20 C I
ZVB C P-15
12" V. DN. I I
I
1" H&CW DN. + 12" I
r-14 I
I � I
I O I I
. I I
HORIZ. VENT &
WATER IN WALL
I i I
I
I I I
I
I i I
I I
/E
I j
I � I
I � I
I I I
I I
02 4
I
I I
I � I
I 4„
� I
O.R.
I
I i I
I � I
V. DN. 2" V. DN. P-14
I
X---------------------- -- — + 2Y I
2 I
P-14 I
-,T 14"�
3" FLUSHING
F L R, DR,
SEE NOTE 1.
FLUSH VALVE
SEE NOTE 2.
ACCESS PANEL
2" V. UP
I
I
1' C.W. &1" R.W. UP
I
I
I
2 1
I
I
I
I
AREA OF WORK
I
__Lm
I
I
I
I
I
L_J
rVl/7
�
O I�
-
7
L
Q I� C:)
O
O
00
� (fl VJ
TT
+� C'4 E U)
D
N O O
N
(�
O
i
� o cu
E�
' o
Q'01z
'
U
O O U
N J
Q
o
LL
c:
�c
11 /19/2021
I I I I I I I I
LLI
Q
0
z
O
L
>
Lu
I I I I I I I I w
I —
a
0
z
O
T
>
Lu
RECEIVED
Nov 21 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v J z
rQ O
V
M z U
W Q
� J
O
Oz �� U
U)0
C) Q � O
zo D r U-
Ow co o
G =ern z w
Q;Q W C)
W �_� U)
co ui
U�.. J co �
tiz V
_�� QRZ O
C� U)N� m Z
ENGINEER: LAST REVISED:
K LARSEN 11-19-21
CHECKED BY: DATE PLOTTED:
D JACQUES 11-19-21
CAD: ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212273-00
SHEET NUMBER:
TP1.01
z
1 /4" = V-0"