Loading...
ENG2021-0507 ROW PERMITOF WAY EUC PERMIT PERMITNUMBER, City of Edmonds AveRIGHT 980 1 1 1 www.cityofedmonds.gov Description: PUD REPLACE PRIMARY UG IN EXISTING CONDUIT ISSUED: 12/30/2021 Address: 8909 238TH ST SW EDMONDS WA 98026-8984 EXPIRES: 06/28/2022 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00463300600300 NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER EDMONDS CREST LLC 4205 NE 169TH CRT, LAKE FOREST PARK WA 98155 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $0.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW ENGINEERING DIVISION ���,.. ,�� • ,.. "DTED RELEASED BY �% �,�/v 2/30/2021 DATE Printed: Thursday, December 30, 20214:31:43 PM 1 of 2 -KRWOF WAY EUC PERMIT PERMIT NUMBER City of • • • Ave•:• • 1 1 1 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROL Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. • INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START X-2 ENGINEERING FINAL" Printed: Thursday, December 30, 2021 4:31:43 PM 2 of 2 ENG2021-0507 PUD WO #100015367-60 j of EpM04O� RIGHT OF WAY CONSTRUCTION RECEIVED PERMIT APPLICATION DEC 06 2021 Complete and submit this Application in accordance with the Submittal CITY OF EDMONDS Requirements outlined in Right -Of -Way permit Handout E6.,I. DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. SECTION A General• Project Name Replace bad order primary cable at Edmonds Crest apartments Site Address or if no site address use Property Address at NW corner of project area: 8909 238th St SW, Edmonds 98026 Associated Permits: BLD n/a PLN n/a ENG n/a • • • applicable) Name of Company Snohomish County PUD Franchise Ordinance No: n/a Point of Contact Richard Dumo Title Engineer Address 1802 75th St. SW, MS02 City Everett State WA Zip 98206 Phone 425-783-5110 Email rsdumo@snopud.com Contractor and Authorized Agent of Owner Name of Company same as above (see note below) Contractor Contacts During Construction Primary Name same as above Agent Name Title Title Mobile Address Email City State Zip Secondary Name Phone Title Email Mobile City of Edmonds Business License No: Email State License No: 313-005-741 IN Contractor verifies it is currently bonded] Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o.o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? cm Other, please specify: PUD Utility work ❑ Utility Franchise Work associated with development (check one of the above boxes as well ❑ Traffic Control Only (no associated development) ❑ Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Scope: Replace bad order primary cable in conduit at Edmonds Crest apartments. Crews will setup on the side of 238th St SW while the other half of the crew will setup and feed new cable in the private parking area. There is no sidewalk but flaggers will be on hand to assist any pedestrians Please include any minor ground restoration if needed and minor vegetation trimming work for permit use. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF n/a Alley 72 hours + LF x LF SF 8 hours Parking 72 hours + LF x LF SF n/a SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable ® power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes X No 2. 1 Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existingunderground common utilitysystem? X 5. Does the work involve proposed additions to an aboveground utility system? If es: X Are the additions for the purpose of serving new commercial development? n/a Are the additions for the purpose of serving a single-family residential subdivision? n/a Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the X project is proposed: 6a. Does your project involve wires/cables/lines? If yes: Primary and Secondary underground cables. X How many are existing? 1 1 1 How many are to be added? I none City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: (Existing take off pole to remain) X How many poles are existing in the project area? 1 What is the height of the existing poles? 45' How many poles are to be removed? 0 Are additional poles to be laced? no How many? I n/a I What is the height of the additionalpoles? n/a 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? 10 1 What is the height of the poles after? n/a Describe the modification rebuild: Old conduit riser will be replaced with new together with primary cable. SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: IeUa4,960 APPLICANT PRINTED NAME: Richard Dumo APPLICANT TITLE: Engineer NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE DATE: 12/6/2021 City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 LAYOUT LEGEND: SNOMOMISM COUWTv pEOo V] PAD MOUNTED TRANSFORMER ® SUBMERSIBLE TRANSFORMER �J ABOVE GROUND J-BOX �J SUBMERSIBLE J-BOX �S SECONDARY VAULT ❑ PULLING VAULT O PAD MOUNTED SWITCH CABINET O SUBMERSIBLE SWITCH CABINET © SMALL SECONDARY PEDESTAL © LARGE SECONDARY PEDESTAL SL STREET LIGHT PEDESTAL PRIMARY UNDERGROUND CABLE —•—•—•-----#350 SECONDARY UNDERGROUND CABLE — — — — — — — — 4/0 SECONDARY UNDERGROUND CABLE 1/0 SECONDARY UNDERGROUND CABLE --—-—STREET LIGHT CABLE SERVICE CONDUIT POLE AND OVERHEAD LINE PROPERTY LINE —RIGHT-OF-WAY LINE U EXISTING UNDERGROUND CABLE EXISTING DUCT — — — — FUTURE DUCT ------- S------ SANITARY SEWER/MANHOLE ------- D------ STORM DRAIN/CATCH BASIN - ------."J-----b WATER MAIN/METER r FIRE HYDRANT $c STREET LIGHT * UNDERGROUND LOCATOR MARKER SCHEMATIC: REFER TO SHEET S1 CONSTRUCTION NOTES: AT PLI 15276 REMOVE EXISTING 1/0 TERMINATION & RELATED MATERIALS, INSTALL NEW 1/0 UG TERMINATION ASSY (12ULD. INSTALL CABLE TAG PER SCHEMATIC. AT VAULT A-5763 EXISTING TREE, TREE STUMP & ROOTS AROUND VAULT WILL BE REMOVED PRIOR TO ELECTRICAL WORK. REMOVE EXISTING 75 KVA 240/120V SUBM XFMR. DIST S- -X SER MAKE INSTALL NEW 50 KVA 240/120V PADMOUNT XFMR (BC12R). UTC SER MAKE INSTALL (2) NEW LOADBREAK ELBOWS (T1105). RECONNECT PRI & SEC CONNECTIONS. INSTALL CABLE TAGS PER SCHEMATIC. NOTE PULL IN EXTRA 20 FEET OF CABLE SLACK INTO VAULT FOR FUTURE POLE REPLACEMENT. AT VAULT A-5764 REMOVE EXISTING 100 KVA 240/120V SUBM XFMR. DIST T- -X SER MAKE INSTALL NEW 37.5 KVA 240/120V PADMOUNT XFMR (BC12P). UTC SER MAKE INSTALL (1) NEW LOADBREAK ELBOW (T1105). INSTALL NEW DUST CAP (T1701). RECONNECT PRI & SEC CONNECTIONS. INSTALL CABLE TAG PER SCHEMATIC. CABLE ALL FOOTAGES APPROXIMATE FROM PLI 15276 TO A-5763 270' OF (1) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN EXISTING 2" PVC MAKE PO REEL FT MARK TO FROM A-5763 TO A-5764 105' OF (1) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN EXISTING 2" PVC MAKE PO REEL FT MARK TO TOTAL FOOTAGE OF 1/0 CABLE INSTALLED: 375' CABLE NOTES: FROM PLI 15276 TO A-5763, REMOVE PRIMARY UGND CABLE# 9585. FROM A-5763 TO A-5764, REMOVE PRIMARY UGND CABLE# 9586. TOTAL FOOTAGE: 370' BLDG B r- 23 BLDG A LAYOUT Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. OWNER/CONTRACTOR IS RESPONSIBLE FOR \ EROSION CONTROL AND DRAINAGE �11 oti os �9 N i- \ NORTH \III \\\ I \ I23710 I �I ENGINEERING DIVISION NOTED /vG__v _12/29/2021 LOCATION 8909 238TH STREET SW EDMONDS 98026 AREA LYNNWOOD POLE NO PLI 15276 SWI/4S 31 T 27 R 4 DATE 11/24/21 ORDER 100015367 REASON FOR WORK REPLACE BO CABLE FOR ENGINEER DUMO OPERATION 0060 EDMONDS CREST DRAFTER McPHERSON UGND No 3243-2 APPROVED SCALE NOTED & DATE DATE WORK COMPLETED FOREMAN SUBSTATION WESTGATE INSPECTOR CIRCUIT NO 12-407 PHASE 3 DATE FEES REO'D ❑YES ■NO ROAD CROSSINGS ONLY PRIMARY OVERHEAD APPV DATE DESCRIPTION ❑ RESIDENTIAL ❑ COMMERCIAL LEO- REVISIONS @$ =$ APPV NO. DATE DESCRIPTION PRIMARY UNDERGROUND ❑ RESIDENTIAL ❑ COMMERCIAL BASIC FEE % LEU- SECONDARY UNDERGROUND BASIC FEES @ $�'= S WORK IN RIGHT OF WAY AS -BUILT ❑ PRIMARY ❑ SECONDARY APPV NO I DATE DESCRIPTION FT @ S = $ MISCELLANEOUS FEES VAULT $ PERMIT $ $ TOTAL DUE$ RECSIR ENGINEER RICHARD DUMO CUSTOMER PHONE (425) 783-5110 PHONE DISTRICT PROJECT LEADER: PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ■ EDMONDS EASEMENTS ❑ REQUIRED E# ■ NOT REQUIRED REQUEST NO. DATE APPROVED FOREIGN CONTACTS ❑ JPN+ ❑ JOINT TRENCH ZIPLY & CATV ❑ JOINT BORE ZIPLY & CATV POLE STENCILING FROM TO TAKE OFF POLE PRE-CONSTR REQUIREMENTS ■ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ■ ONE CALL DATE STREET LIGHTING ❑ YES ■ NO UILT H74, RMIAPPAGE CIS USE H2 rc ED ONDS J IL zzoTW ST sw 3 e° �o 101 zsm sT SW f ��g s -WORK - SITE r.. WOODWAY ST STw S J J KING 21- sT sw COUNTY RECEIVED VICINITY MAP DEC 06 2021 TAGS Z a o� VAULT: EXISTING CITY OF EDMONDS CP4 ^" DEVELOPMENT CABLE: 111889 & 111890 tV SERVICES DEPARTMENT _ U41 3n 1 LLo SIGN SPACING = X FREEWAYS & EXPRESSWAYS 55/70 MPH 1500'± RURAL HIGHWAYS 60 /65 MPH 800'± RURAL ROADS 45 / 55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35 /40 MPH 350'± RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTAL & BUSINESS DISTRICTS 200'± (2) URBAN STREETS 25 MPH OR LESS 100'± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. ONE LANE, TWO—WAY TRAFFIC TAPER SPECS TAPER TYPE LENGTH (feet) # OF DEVICES UPSTREAM TAPER 50' TO 100' 6 DEVICE MIN. DOWNSTREAM TAPER 50' TO 100' 6 DEVICE MIN. TABLE (1) CHANNELIZATION DEVICE SPACING (FEET) MPH TAPER TANGENT 50/65 10 TO 20 80 35/45 10 TO 20 60 25/30 10 TO 20 40 MANDATORY Typical One.Lane, Two.Way Operation TRAFFIC CONTROL PLAN �, EDMONDS, WA CLOSURE AFFECTS RESIDENT ROAD o E/B 238'ch Sc SW closed between Edmonds Way & 9fh PI W. DRIVEWAY. AHEAD \ \ '••.. O FLAGGERS shall alternate' traffic, as needed. N wzo.; \ O¢ O Sidewalk on the south side of 238fh St SW closed within PROPERTY OWNER PERMISSION REQUIRED TO BLOCK DRIVEWAY. \ \ . s fy \ O the work area. Due to limited crosswalk access, a Pedestrian Escort will W E \ 10, `••..s safely escort pedestrians through the work area. NOTIFK AFFECTED RESIDENT OF \ \ O Parking Lane closed within the work area. S WORK TIMES/DATES. Applicant shall repair/replace all provem to utilities or \ improvements in City right-of-way \ O (see TCP for locations) Bike Lane not present. NOT TO SCALE per city standards that is caused or \ \ O Transit Route not present. occurs during the permitted project. BE \ PREPARED STo" w3 4 \ \ o REASON: To replace BO cable for Edmonds Crest Apt. Bldg. OWNER/CONTRACTOR IS RESPONSIBLE FOR from eKisting Pole # PLI 1152176. EROSION CONTROL AND DRAINAGE \ \ DURING HOURS OF DARKNESS, FLAGGER STATIONS SHALL BE ILLUMINATED WITHOUT CAUSING GLARE TO THE TRAVELING PUBLIC USING PORTABLE LIGHT TOWER OR APPROVED ALTERNATIVE. WAC 296,155,305 SECTION 9(C) 281� REFL. CONE MAINTAIN 11' MIN. TRAVEL LANE WIDTH 238t'h St SW ROAD ONE LANE WORK ROAD ■ � AHEAD AHEAD W2.0.1 W20.4 W20.I/ IL W3-4 Q ROAD WORK AHEAD t W204 MANDATORY DURING NONWORKING HOURS, TRAFFIC CONTROL SHALL BE REMOVED AND ROW SHALL BE OPENED TO ITPS FULL WIDTH ADDL. NOTES: GENERAL NOTES: 1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD SPECS. 2. NOTIFY LOCAL EMERGENCY SERVICES OF CLOSURE TIMES AND DATES (OPTIONAL). 3. SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROAD CONDITIONS. 4. PROTECTIVE VEHICLE RECOMMENDED.MAY BE A WORK TRUCK. 5. ALL SIGNS MIN. 48'° 1i UNLESS OTHERWISE SPECIFIED. 6. CHANNELIZATION DEVICES ARE 28'/' REFL. CONES (see TABLE (1) for spacing distances). 7. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT.GRADE INTERSECTIONS AND/OR DRIVEWAYS. W 3.4 W20.Pa ........................ *W20.Pa IL BE � PREPARED Q TO sTOP W3.4 ROaD WORK AHEAD W2o.; \ \ SPEED ADVANCE WARNING SIGNS \ \ 4LIM0 SPACED @ (K) OR AS PER \ \ SITE CONDITIONS. REFER TO SIGN SPACING CHART. W20.Pa Edmonds Crest Apts: \ \ 8833 238fh St SW \ \ Edmonds, WA 98026 \ \ ■�' ONELANE W20.Pa AHEAD W20.4 too< \ \................................................................ �I ono 0 0 0 .... r.................................................................... PLI 15276 \ \ ENGINEERING DIVISION NOTED D FROM 0 \ 1 O'� \ RESIDENCE: —12/29/2021 1 \� TOW AWAYAREA •.• 8826 238'th St SW F� \ Edmonds, WA 98026 DISPL/YED IP2 HRS IN �Q% \ DV/ NCE OF CLOSURES LEGEND �y RECEIVED DEC 06 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ❑ LJ J L C WORK AREA 28" REFL. CONE iiiiiiiiiiii own SIGN LOCATION 90MARD PROTECTIVE/WORK VEHICLE FLAGGING STATION NO PARK BARRICADE POLE LOCATION (PLI 15276) 14"ASh'12, GTOA S: A E TRAFFIC C04?ROL SUPERVISOR ROAD WORK &'AVE: Greg Siler AHEAD TCS CARD # 012604 EXP. DATE 1013112024 Greg suer ROAD WORK AHEAD w2o.;