APPROVED BLD PLN RESUB1 BLD2021-0274+PLANS+5.7.2021_9.19.06_AM+218452716706 74th Pl W Edmonds Residence
APPROVED BY PLANNING
May 25 2021
Special Inspection reports required
for this project to consist of:
1) Soils
2) Installation of Helical piles and
brackets
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
5201123-1XR
City Of Edmonds
Building Department
Work FOUNDATION STABILIZATION
----------------------------------------------------
Address 16706 74TH PL W
Owner AMEN
Approved Date 5/20/2021
------------------------------
-----------------------------
Building Official ; � w• � v�a�c
Permit Number
Ri n�m�_n��a
PROJECT INFORMATION
CLIENT
AMEN TIMOTHY & MACLACHLAN STEPHANIE A
16706 74TH PL W
EDMONDS, WA 98026
PROJECT ADDRESS
16706 74TH PL W
EDMONDS, WA 98026
STRUCTURAL ENGINEER
L120 ENGINEERING &DESIGN
13150 91ST PL NE
KIRKLAND, WA 98034-5901
PHONE: (425) 636-3313
CONTACT: MANS THURFJELL, PE
CODES
ENGINEERED PER:
2018 (IRC) INTERNATIONAL RESIDENTAL CODE
2018 (IBC) INTERNATIONAL BUILDING CODE
SHEET INDEX
COVER SHEET....S-0
STRUCTURAL GENERAL NOTES....S-1
SITE &FOUNDATION PLAN....S-2
FOUNDATION DETAILS....SD-1.1
RESUB
May 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
• f R ■ • • #
i + � . T � �j��4 •
4 �t+�i�� ���
■ G. � A
■ •
� � � �
� � �. r
* ♦ �f�..i i�}� �. �C� * 4
r • � r � * s
W
� �
z o
W �
_ � c�
,R z
I— �
w
Zwz
z �
O O z
w
J
�.
REVISIONS
0 DESCRIPTION DATE BY
PROJECT NAME
16706 74TH PL W
EDMONDS, WA
98026
PR���., I NUMBER
S201123-1XR
DRAWN � � - ZT
CHECKED BY M RT
SHEET DATE 5/6/2021
S(;�
z
O
o
DC
�
(n
�
W
V
>
w
�
O
w
U
w
GENERAL STRUCTURAL NOTES
DESIGN CRITERIA
CODE: 2018 SRC/SBC &AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY.
ROOF........................................25 PSF SNOW (GROUND)
FLOORS
RESIDENTIAL .....................40 PSF
BALCONY/DECK................60 PSF
GENERAL CONDITIONS
1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL
ENGINEER OF ANY DISCREPANCIES HE MAY FIND BEFORE PROCEEDING WITH THE WORK.
2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE
STARTING WORK. THE ARCHITECT/ENGINEER SHALL IMMEDIATELY BE NOTIFIED IN WRITING OF ANY
DISCREPANCIES.
3. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL
BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE
PROCEEDING WITH ANY WORK SO INVOLVED.
4. IN CASE OF CONFLICT, NOTES AND DETAILS OF THESE STRUCTURAL DRAWINGS SHALL TAKE
PRECEDENCE OVER THE "GENERAL NOTES" AND/OR "STANDARD DETAILS".
5. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE
SAME AS FOR SIMILAR WORK.
6. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE
DRAWINGS.
7. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY
CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE
DISTRESS TO THE STRUCTURE.
8. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE
FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE
ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION.
9. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION OF THE
INTERNATIONAL BUILDING CODE, AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER
ANY PORTION OF THE WORK.
10. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.
WHERE THE NOTES, DRAWINGS, AND/OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT
SHALL APPLY.
11. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES
OR THE STRUCTURAL DRAWINGS.
12. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION.
13. DISCREPANCIES FOUND BETWEEN STRUCTURAL DRAWINGS AND OTHER DOCUMENTS ARE TO BE NOTED
IN WRITING TO THE ENGINEER PRIOR TO CONSTRUCTION.
14. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS
GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE
"INTERNATIONAL BUILDING CODE" (IBC), AND STANDARDS REFERENCED THEREIN.
15. STRUCTURAL STABILITY OF ALL NEW AND EXISTING STRUCTURES DURING CONSTRUCTION SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR. THIS INCLUDES EXCAVATIONS, COLUMNS, EQUIPMENT
LOADS, MATERIAL LOADS, AND OTHERS. OBSERVATIONS BY THE ENGINEER -OF -RECORD DO NOT
INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING CONSTRUCTION.
16. MINIMUM ASSUMED SOIL BEARING CAPACITY ............... 3,000 PSF
CONCRETE ANCHORS
1. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG TIE, HILTI, OR EQUIVALENT. SPECIAL
INSPECTIONS REQUIRED.
STRUCTURAL AND MISC. STEEL
1. REFERENCE STANDARDS: DESIGN, FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE WITH THE
LATEST EDITION OF THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES".
2. MATERIALS:
BOLTS -ASTM A307, UNLESS OTHERWISE NOTED
WF BEAMS -ASTM A572-50 (Fy = 50,000 PSI)
HSS ROUND COLUMNS -ASTM A500 Gr. B (Fy = 42,000 PSI)
HSS RECTANGULAR COLUMNS -ASTM A500 Gr. B (Fy = 46,000 PSI)
ALL OTHER STEEL -ASTM A36 (Fy = 36,000 PSI)
STRUCTURAL STEEL WELDING
1. CONFORM TO THE AWS CODES D1.1 AND D1.3., AND USE ONLY CERTIFIED WELDERS. WELDS NOT
SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY E70 ELECTRODES.
DI TFR�I�TFC�
1. ALTERNATE ASSEMBLIES AND MATERIALS WILL BE CONSIDERED FOR REVIEW. ENGINEER MAY REQUEST
PAYMENT FOR REVIEW; CONTRACTOR WILL BEAR BURDEN FOR ADDITIONAL PAYMENT AT NO ADDITIONAL
COST TO OWNER.
JOBSITE SAFETY:
1. THE ENGINEER AND/OR ARCHITECT HAVE NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN
AND/OR CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR
TO MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES FOR THE CONTRACTOR TO PERFORM
HIS WORK. THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER AND/OR ARCHITECT SHALL
NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR
PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF WORK BY THE CONTRACTOR, SUBCONTRACTORS,
SUPPLIERS OR THEIR EMPLOYEES, OR FOR ACCESS, VISITS, USE, WORK, TRAVEL, OR OCCUPANCY BY ANY
PERSON.
HELICAL PILES
1. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2018 INTERNATIONAL
BUILDING CODE (IBC).
2. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY IDEAL MANUFACTURING, INC., AND SHALL BE
IN ACCORDANCE WITH ESR-3750.
3. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH ESR-3750.
4. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE
CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA)
COATINGS (AC228).
5. ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE
REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER
AC358 SECTION 3.9.
6. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS.
7. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED.
8. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF
INCLINATION OF +/- 1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-3750.
9. MONITOR AND RECORD DEPTH OF PILE PENETRATION. PROVIDE TORQUE MONITORING DEVICE AS PART OF
THE INSTALLING UNIT. MONITOR AND RECORD TORQUE APPLIED DURING THE INSTALLATION OF EACH PILE
AT SPECIFIC DEPTHS.
10. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE
MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS
THAN TWO (2). THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL
CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY.
11. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE
THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2).
12. REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE FULLY
ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION.
13. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE TORQUE
REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES.
14. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT
WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION.
15. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2O18 AND 2012 IBC SECTION 1705.9 MUST BE
PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION BRACKETS. ITEMS TO BE
RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST INCLUDE THE FOLLOWING:
A. PRODUCT MANUFACTURER
B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS
C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS, EXTENSIONS,
BRACKETS, BOLTS, THREADED RODS, NUTS, WASHERS, AND TORQUES AS SPECIFIED IN THIS
REPORT AND THE CONSTRUCTION DOCUMENTS
D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT, INSTALLATION EQUIPMENT USED, AND
THE IDEAL FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS
E. ANTICIPATED AND ACTUAL PILING DEPTH
F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION
G. INCLINATION AND POSITION OF PILES, TOP OF PILE EXTENSION IN FULL CONTACT WITH BRACKET,
TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS ARE INSTALLED
BY AN APPROVED IDEAL FOUNDATION SYSTEMS INSTALLER.
16. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER
SPECIFIED DESIGNIINSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND
INSTALL ADDITIONAL PILES AS REQUIRED.
HELICAL PILE PROOF TESTING
THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3)
PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE
OUTLINED IN ASTM D1143 ANDIOR THE 2018 SEATTLE BUILDING CODE (SBC). THE MAXIMUM TEST LOAD SHALL BE
TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD.
ABBREVIATIONS
AB
ANCHOR BOLT
FTG
FOOTING
ABV
ABOVE
GA
GAUGE
AFF
ABOVE FINISH FLOOR
GALV
GALVANIZED
ALT
ALTERNATE
GLB
GLULAM BEAM
ALUM
ALUMINUM
GR
GRADE
APPROX
APPROXIMATE
GYP
GYPSUM WALL BOARD
AYC
ALASKAN YELLOW CEDAR
HDG
HOT -DIPPED GALVANIZED
BB
BOX BEAM
HDR
HEADER
BF
BOTTOM FLUSH
HF
HEM FIR
BLDG
BUILDING
HGT
HEIGHT
BLKG
BLOCKING
HT
HEIGHT
BM
BEAM
IN
INCH
BOT
BOTTOM
JT
JOINT
BP
BOTTOM PLATE
MAX
MAXIMUM
BRG
BEARING
MIN
MINIMUM
BTWN
BETWEEN
MISC
MISCELLANEOUS
BSMT
BASEMENT
NB
NON -BEARING
B/W
BOTTOM OF WALL
NO
NUMBER
CANT
CANTILEVER
OC
ON CENTER
CJ
CONTROL JOINT
PSF
POUNDS PER SQUARE FOOT
CLG.
CEILING
PSI
POUNDS PER SQUARE INCH
CU
CEILING JOIST
PT
PRESSURE TREATED
CLR
CLEAR
CMU
CONCRETE MASONRY UNIT
RAF
RAFTER
COL
COLUMN
REF
REFERENCE
CONC
CONCRETE
REINF
REINFORCEMENT
CONN
CONNECTION
REQD
REQUIRED
CONST
CONSTRUCTION
SF
SQUARE FOOT
CONT
CONTINUOUS
SIM
SIMILAR
CTR
CENTER
SPF
SPRUCE PINE FIR
DET
DETAIL
STD
STANDARD
DF
DOUGLAS FIR (SOUTH)
SYP
SOUTHERN YELLOW PINE
DFL
DOUGLAS FIR LARCH
T/
TOP OF
DIM
DIMENSION
T/C
TOP OF CONCRETE
DJ
DOUBLE JOIST
T/P
TOP OF PLATE
DIA
DIAMETER
T/S
TOP OF STEEL
DN
DOWN
T/W
TOP OF WALL
DS
DOWN SPOUT
TF
TOP FLUSH
EA
EACH
TJ
TRIPLE JOIST
EF
EACH FACE
T/BM
TOP OF BEAM
E]
EXPANSION JOINT
ELEV
ELEVATION
T/SLAB TOP
OF SLAB
EN
EDGE NAILING (PANEL)
TP
TOP PLATE
EQ
EQUAL
TYP
TYPICAL
ES
EACH SIDE
UNO
UNLESS NOTED OTHERWISE
EW
EACH WAY
UPA
UNDER POST ABOVE
FB
FLUSH BEAM
UWA
UNDER WALL ABOVE
FIN
FINISH
VERT
VERTICAL
FL
FLOOR
VIF
VERIFY IN FIELD
FLSHG
FLASHING
W/
WITH
FND
FOUNDATION
WC
WESTERN CEDAR
FP
FIREPLACE
Wp
WATERPROOF
FT
FOOT
WWF
WELDED WIRE FABRIC
SPECIAL INSPECTIONS SCHEDULE
SPECIAL INSPECTIONS TABLES PER THE 2018 IBC. ALL ITEMS NON -APPLICABLE ITEMS HAVE BEEN
MARKED WITH A "-". ITEMS REQUIRING SPECIAL INSPECTION HAVE BEEN MARKED WITH AN "X".
TABLE 170�.3
REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
CONTINUOUS
PERIODIC SPECIAL
REFERENCED
IgC
TYPE
SPECIAL
IN5PECT10N
INSPECTION
�
STANDARD
REFERENCE
1 _Inspect reinforcement. including prestressing
ACI 31 S Ch. 2D. 25.2.
tendons. and verify placement.
25.3, 26.5.1-2G_5.3
1905 4
2_ Reinforcing bar �n�elding:
a_ Verify weldability of reinforcing bars
_
other than ASTM A �06:
_
AWS D1.4
b. Inspect single -pass filet welds. maximum
ACI 31 S: 28.5.4
�r ��: and
-
�a
c. Ins ect all other welds_
3. Ins ect anchors cast in concrete_
-
-
ACI 31 S: 17_S_2
-
4.Inspect anchors past -installed in hardened
concrete members_
a. Adhesive anchors installed in hari�ontally
ar up},xrardly inclined orientations to resist
-
-
ACI 31 S: 17_S_2.4
-
sustainedtension loads.
b. Ivlechanical anchors and adhesive anchors
not defined in 4.a
5. Verify use of required design mix.
-
-
ACI 318: Ch_ 19_
1904.1. 1904.2.
2G_4.3. 2G.4.4
19D8.2. 1905.3
6_ Prl4r to Can Crete placement_ fabricate Specimens
ASTM C 1 �2
far strength tests, pertorm slump and air
-
-
ASTM C 31
1905.1 D
can#ent tests. and determine the temperature of
ACI 31 S: 26�_4.5, 28.12
the concrete_
7. Inspect cancre#e and sha#cre#e placement for
-
-
ACI 31 S: 26.4.5
190S.G. 1905..7.
ra era licatian techni ues.
190S.S
S.Verify maintenance of specifed curing
-
-
ACI 318: 28.4.�-26.4.9
1905.9
tem erature and techni ues_
9. Inspect prestressed concrete far:
a. Application of prestressing farces: and
-
-
ACI 31 S: 26.9.2.1
-
b. Groutin of banded restressin tendons.
-
-
ACI 31 S: 2G.9.2.3
10. Ins ect erection of recast concrete members.
-
-
ACI 318: Ch. 2G.S
-
11. Verify in -situ concrete strength. prior to stressing
of tendons in past -tensioned concrete and
-
-
ACI 31 S: 26.10.2
-
priar to removal of shares and farms from
beams and structural slabs.
12 Inspect formwork far shape. location and
dimensions of the concrete member being
-
-
ACI 31 S: 26.10.1 fib}
-
formed.
TABLE 'I 10�.7
REQUIRED SPECIAL INSPECTIONS AND TESTS CF DRIVEN DEEP FOUNDATION ELEMENTS
TYPE
CONTINUOUS SPECIAL INSPECTION
PERIODIC SPECIAL INSPECTION
1. Verify element materials. sires and lengths comply with
�
-
the re uirements_
2. ❑etermine capacities of test elements and conduct
�
-
additional load tests_ as re aired.
3. Inspect driving operations and maintain complete and
�
-
accurate records for each element.
4. Verify placement locations and plumbness. confirm
type and Size of hammer, record number of blows per
faa# of penetration. determine required penetrations to
K
-
achieve design capacity, record tip and butt elevations
and document an lama a to foundation element.
5_ Far steel elemen#s, perform additional special
ins ections in accordance wi#h Section 1 �0� 2.
_
_
G_ For concrete elements and concrete -filed elements,
perform tests and additional special insp�ectians in
-
-
accardancewith Section "01 �s.
7_ For specialty elements. pertorm additional inspections
as determined by the registered design professional in
-
-
res ansible char e_
RESUB
May 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
+ { ■ ■ • t #
i • � . 1• .H �J��4 •
* � Lam. � Q '.
■ A
*� � .
ti � �� �, •
# # `��O��IA �-
# + r ■ � + •
W
(3
(n
Zo
W °�
_ > c�
Z_
W
zWz
Z�
O O Z
W
J
�' .
REVISIONS
DESCRIPTION
DATE
BY
PROJECT NAME
16706 74TH PL W
EDMONDS, WA
98026
PR�,��CT NUMBER
S201123-1XR
DRAWN � � - ZT
CHECKED BY M RT
SHEET DATE 5/6/2021
5C�
W
z
J
Q
oC
U
ILL
o Q
�
I
oC
U)
V W
�, z
w Lu
��
w
w
�
BLD2021-0274
SITE NOTES
1. VERIFY ALL DIMENSIONS ON SITE.
2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL
PER R&R LEVEL SURVEY.
3. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED MAY 6TH,
2021, FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND REQUIREMENTS.
4. LEVEL SURVEY PER R&R REPAIR PLAN DATED NOVEMBER 19TH, 2020. REFER
TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND
ADDITIONAL REQUIREMENTS FOR REPAIR PLAN.
5. PARCEL DIMENSIONS PROVIDED BY SNOHOMISH COUNTY. NOT TO SCALE.
PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS (WITH ASTERISK, *)
APPROXIMATED PER SNOHOMISH COUNTY GIS MAPPING TOOLS. NOT TO BE
USED FOR LEGAL PURPOSES.
6. SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT
SHOWN FOR CLARITY.
■ � . � ■ PROPERTY LINE
■ ■�',�■�■�■� NOTES:
185'.0
PILE SPACING $c LOAD REQUIREMENTS TABLE
MAX ❑.C. SPACING, ft
MIN VERTICAL CAPACITY, kips
PROOF TESTING LOAD, kips
PILE #
PILE TYPE
BTWN PILES
END OFFSET
ALLOWABLE LOADING
zoa�° MIN VERTICAL CAPACITY
MIN ULTIMATE CAPACITY]
LOCATION
1-6
HELICAL
N�A
NfA
9.0 kfPILE
18.0 k�PILE
POSTS
7-12
HELICAL
6'-0"
PER PLAN
13.0 kfPILE
25.0 k�PILE
TYP EXTERIOR
TIEBACKS SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE MINIMUM REQUIRED LOAD NOTES:
CAPACITIES INDICATED ON PLAN WITH AN ADDITIONAL FACTOR OF SAFETY OF 2. THE MAXIMUM INSTALLATION TORQUE
SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE TIEBACK ASSEMBLY. a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE
� MANUFACTURER. THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING
j CAPACITY LOADING, INCLUDING A SAFETY FACTOR NO LESS THAN 2. THE MAXIMUM INSTALLATION TORQUE SHALL NOT
EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY. MAXIMUM
■ INSTALLATION TORQUE RATING OF 8,300FT*LBS FORA 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL
' THICKNESS PER ESR-3750.
' b. FOR HELICAL PILES, PER IDEAL GROUP DWG NO.: 278TFG, THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8"
TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS.
c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING, INC., IN ACCORDANCE WITH ESR-3750.
' d. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART
OF THE ASSEMBLY.
I ' e. MAXIMUM ON -CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN.
■
I �
w. P�
JI� o'vEw
� ' c PRESS
a'�
oIN j
ai AREA OF WORK -�
I i ' � 9�_6�� 25�_0�� �, -v
I (E) 2ND FLOOR I r
_� ' �
. I � -
I I-
to I '
• I ' '
I I� I .
I � ' '
• I
I I
I '
I -v
I I ' O
� � o'
I I b' �
! I -<
I �■r
I —
RESIDENCE i i � PRIMARY '
I 16706 74TH PL W '- � AccEss ■
' EDMONDS, WA 98026 �
■ (E) DECK �
j oR�vESSY
I �
PCGE
I 25�_0�� �
I
I
I
I
I
I
I
I
I
I
■
TIEBACK SPACING & LC}AD REQUIREMENTS TABLE
MAX O.C. SPACING, ft
MIN VERTICAL CAPACITY, kips
PRCIOF TESTING LOAD, kips
TIEBACK
TIEBACI{ #
2aa°�° MIN VERTICAL CAPACITY
LOCATION
TYPE
BT1NN PILES
END OFFSET
ALLOWABLE LOADING
MIN ULTIMATE CAPACITY
TYP
HELICAL
5'-0"
PER PLAN
11.0 k�PILE
22.0 k�PILE
TYP E7CTERIQR
I I
' �
AREA OF WORK I I '
' � �
I I
I �,
I �.
I
A
(E) RETAINING WALL � (E) COVERED PATIO �;o,O�
�---' sr �'�'�
■ PROPERTY LINE
SITE PLAN LEGEND
EXISTING RESIDENCE STRUCTURE
r--�
EXISTING ADJACENT STRUCTURE
r - - �
AREA OF PROPOSED WORK
PROPERTY LINE
- - - - APPROXIMATE DIMENSION
�o, � y���
.� � �
.`
NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN REsu6
May 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
+ f R ■ • t #
i + � . T � �j��4 •
■ G. � A
w� � .
� �.� �, •
*. �'far���. �*.
r � � r � * s
W
� �
z o
W �
_ � c�
,R z
��
w
Z W z
z �
O O z
w
J
�.
REVISIONS
0 DESCRIPTION DATE BY
PROJECT NAME
16706 74TH PL W
EDMONDS, WA
98026
PR���CT NUMBER
S201123-1XR
DRAWN � � - ZT
CHECKED BY M RT
SHEET DATE 5/6/2021
S(;�
z
z Q
o J
N
�
�
�
� W
V
p (f)
w
w
BLD2021-0274
�� � �� ��
T/STEM WALL
(E) WOOD FRAMED
�-� c� w
V
FLOOR SYSTEM, I
�, � �
(E) RETAINING WALL
FIELD VERIFY
� o '�'
�
d T/FIN GRADE
----------------------- -------- �
i
LL
I�
°
����IIII����IIII=I
I
WOOD POST PER PLAN
`� IIII =IIII =IIII TIE -BACK
I
E CONC STEM WALL
()
[NOTE 4]
_ _'_
� � �� -
�'
a = I� I =IIII = ANCHOR DETAIL
II II � I I _ � PER SSK-02
(4) #4 VERTS, SIMPSON CB66
�. TIE -BACK - - — - - — - — - — - — -�— � �
= I I =IIII
T/STEM WALL =
(1) @ EA CORNER POST BASE [NOTE 2]
� ;;�
��
`" IIII =IIII =IIII
-118"MIN THICKNESS,
��
8 MIN THICKNESS,
FIELD VERIFY
o
1-6 SQ x 1-2 DP
T � -
� �,
- I - I=�I�TRACTOR TO VERIFY
�
CONTRACTOR TO VERIFY��- � �•��
` 'III
T/FIN GRADE _�
VARIES
(E) CONC � o
� CONC PILE CAP [NOTE 1]
SLAB -ON -GRADE �
=IIII = _ =III'
d =IIII =IIII
IIII =IIII =IIII
=
_
_ _ _ _ _ _ _ N T/GONG SOG _
x
�
-
� � TIE -BACK
IIII=IIII=IIII
� � - - I I I =IIII =III
_ �
c�o� a 'IIII=IIII_1111=
LL, � �
E FTG TO BE CUT FLUSH
O
- WITH FACE OF STEM WALL
- w FIELD VERIFY
- -_ - -_ - - - ' - -� �
:IIII=IIII- I- l - II_lll—llll�lll
i =IIII =� I�� � - I I = �1'=
o L -
� o � ��—�
r�; -;'
� � ;;� �
— --IIII =IIII = ANCHOR DETAIL
IIII�IIII— PERSSK-02
= I ICI I - I = �
_ _ _
� -
�.TiE-BACK _ _ _ _ _ _�
d
=Q� _IIII_IIII_IIII_
,.,_,
z � -IIII=IIII=IIII
- ~ > .. ° -IIII=IIII-IIII=
II WITH A 12" MAX WIDTH FOR
INSTALLATION POCKET
_
�` IIII_l�1'= �o� II=��1 =IIII-
�;
� =IIII_=II—�PI I =
�
� °
IIII III=IIII=
� LOCATE PILE TO
=IIII=IIII=11,
ENSURE BYPASS
�, o � " � a� 'IIII=IIII= II-1
� = - _ �=�I�I=� IIII
`~' ''I
.
o '�� � _—"
-IIII=IIII=
III=11�1=�. OF FTG
�
=IIII I =IIII IIII=IIII IIII-11�'
� �
=11
N � =IIII-11 =IIII=
� • - I I I 11=
I I T/GONG FTG =
—
—III IIII= � 1=IIII-1 II=''�
(2) #4 HORZ - II=III =IIII- IDEAL HELICAL PILE &NEW
`" x ° -
Q
d IIII=IIII=-`IIII_��,
=IIII=IIII= —II
'III=IIII=IIII=IIII=IIII-11 :- :- III=IIII=1
� �
-i��I=III
FIELD VERIFY
TOP&BOTTOM -IIII=1 1= ' CONSTRUCTION BRACKET PER
� �
T/FIN GRADE ,,,, �,�, ,_I�.
" IIII=IIII=11 I=III _�
= _
I_IIII_IIII d d IIII_IIII:
`� I I =IIII = I I III =IIII
=
= I
EA WAY 1,_6„ R&R FOUNDATION SPECIALIST
_
- T - �
IIII-IIII�IIII-11 a '=
- --�-- _
-
= d � -� T/GONG FTG
� �
IIII_IIII - d IIII=IIII
TO CONFORM TO ESR-3750
.�=
(IIII= I=IIII= - ° -
IIII-11
° - �,_ I-f-I, FIELD VERIFY
IIII=
=1 �_° _� _III=IIII=
�''
NOTES:
=IIII �-
IIII-1 II=IIII= ' " � a�
�- �-
" � a� " � a� I=IIII.
=11 =IIII=IIII=III IIII=IIII='
III-1�li
1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF f'c = 2,500PS1.
-IIII IIII-11 � �
_ d
� � � IIII-1
d d
-IIII=IIII=IIII=1
(E) CONTINUOUS '� ��
IDEAL HELICAL PILE &REPAIR
2. COLUMN FASTENER QUANTITY AND SIZE PER SIMPSON STRONG -TIE.
_ = 11- _ _
=IIII=IIII III=IIII=IIII=IIII=IIII=IIII=IIII=IIII=
_ _ _ _ I=IIII
CONC FOOTING
BRACKET ASSEMBLY PER
3. MINIMUM COLUMN BASE EMBEDMENT DEPTH PER ESR-3050.
�I'i- III=IIII=IIII=IIII=IIII=Ili'-
""-'�
NOTES:
R&R FOUNDATION SPECIALIST
4. WOOD MEMBERS MUST BE EITHER SAWN OR ENGINEERED LUMBER RECOGNIZED
E CONTINUOUS
() -I„i= ,�I�-�•••-����-•�
1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION
TO CONFORM TO ESR-3750
IN AN ICC-ES EVALUATION REPORT.
CONC FOOTING
DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE
NOTIFIED PRIOR To INSTALLATION IF MINIMUMs NOT MET.
It should be noted that detail size specified here is smaller than that called for in ESR-3750. This ESR report
NOTES:
2. ALL AssEMBLY coMPONENTs sHALL BE FULLY SEALED BY A ____=
is created for an application which is utilizing 100% of the helical pile and concrete footing abutment capacity.
1. CONTRACTOR TO VERIFY NOTED MIN &MAX EXISTING FOUNDATION DIMENSIONS PRIOR TO
CORROSION RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT `------- _=====-
Our application, as seen in the structural package, illustrates a condition with an isolated post -load and
INSTALLATION. ENGINEER -OF -RECORD TO BE NOTIFIED PRIOR TO INSTALLATION IF REQUIREMENTS
ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING
post -base connection to an isolated pile supported concrete footing (GIP) where a vertical demand anticipated
NOT MET.
SYSTEM BY OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION
PER ASTM 153/A123.
to be no more than 50% of the helical Ile ca acit er ESR re ort Additional) in our a Ilcation it is
p p y �p p )' y� pp
2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION RESISTANT SYSTEM. THIS
3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL
assumed that no rotational moment at the base of each column is resisted by the pile, footing, nor by the
INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING SYSTEM BY
REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT
column base, hence the footing size utilized in this "lighter" application may be reduced to the size depicted in
OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123.
coRRosloN.
the structural detail.
�
HELICAL PILE INSTALLATION DETAIL
2
PILE CAP AT POST
3
RETAINING WALL -PILE INSTALLATION DETAIL
(E) FOUNDATION WALL, �
8" MIN THICKNESS, I =IIII =IIII =IIII
FI ELD VERI FY � � 'IIII =IIII =IIII =IIII
: FILL CUTOUT WITH
- I =IIII =IIII =IIII
=' STRUCTURAL GROUT
PL1/2" x 6" x [a + 1 "] . -a �, I I I I I I I I I I I I I I I I I I I I11 �
I I I� POST -INSTALLATION
BEARING PLATE, � .
' ' IIII=IIII-11
_III
CTRD AT CUTOUT ; ' - I =IIII =III
=, TIE -BACK ANCHOR
-IIII
' ° IIII =III -IIII =III
= ADAPTER AND
''`� ��� � a� IIII -IIII-11
'III
_I' WASHERS PER R&R
\o��, � _IIII=_=III
�' � ' ' -IIII = =IIII
� � =
= HELICAL TIE -BACK
��'�j - IIII I =IIII =IIII
ANCHOR PER R&R
o J�� ., I III_IIII_IIII
c, IIII=IIII=IIII=
I,
1-
' - I =IIII =IIII = I I
1"O (MIN) THRD ROD `�� .,� _@_
= HORIZONTAL PLANE
_�
W/ STD NUT I=IIII IIII-
I I = I I
=INCLINATION ANGLE,
I�Y�5°
_ =
' - I-IIII= III_IIII=,,.
MIN, 30° MAX
PL TO CHANNEL ;
EA END OF PL 1�4 �- ° IIII=IIII=
-IIII=IIII=
a 1=IIII=IIII=III
' ' IIII=IIII=IIII=IIII
i i
_ 1=IIII=IIII=IIII=III=1
' ° IIII=IIII=IIII=IIII=_
— III=III,
_ 11=IIII=IIII=
IIII=III
IIII=IIII IIII=
..
' 1=IIII=IIII- '�
VERT C10x15.3 CHANNEL
'IIII=IIII=
" IIII=IIII= IIII
�111=IIII=IIII
CTRD AT TI E-BACK � � • - I =IIII = I I
' " " "
RUNNING FULL HEIGHT OF WALL � � � - IIII =IIII
1=IIII-11�
� � d _
. ' ' IIII=IIII—'
' _ =IIII—III
NOTES:
1. C10x15.3 CHANNEL TO RUN VERTICALLY FULL HEIGHT OF WALL
AT PILE LOCATIONS.
CROSS-SECTION SHOWN HORIZONTAL HERE ONLY FOR DETAILING
PURPOSES.
2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION RESISTANT SYSTEM. THIS
INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING SYSTEM BY
OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123.
3. SUPPLEMENTAL STEEL TO BE ANCHORED TO CONCRETE WITH 5/8" DIAM SIMPSON TITEN HD SCREW
ANCHORS @ 12"OC WITH A 4"MINIMUM EMBEDMENT.
4
TIEBACK INSTALLATION DETAIL
5
NOT USED
6
NOT USED
RESUB
May 07 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
,,.�.�.
t �ryF 'i�r1.'y '� •
■ U. � z �
■ r
s '� � •
a � q.� r
•
� �. IhhLI:k ' { �+ r
�# ���iVri L- � 4f
.+,.,,.
W
� �
� �
Zo
W °�
_ � �
z
� �
w
Z W z
Z z
O � W
REVISIONS
Q DESCRIPTION DATE BY
PROJECT NAME
16706 74TH PL W
EDMONDS, WA
98026
PROJECT NUMBER
S201123-1 XR
DRAWN D T - ZT
CHECKED BY - M RT
SHEET DATE 5/6/2021
SC.
J
a
0
z
O
-
o Q
�
0
�
z
U
w p
�
w
LL
w
=
BLD2021-0274