Loading...
FINAL SI REPORT1 of 6 LONGITUDE ONE TWENTY" ENGINEERING & LIESIGN Pile Review for Structural Compliance Date: November 29"', 2021 Project Name: Foundation Stabilization/Lift — Edmonds Project Number: S201123-1XR Project Location: 16706 74th PI W, Edmonds, WA 98026 Client's Name: Andi Hohn, Project Coordinator — R&R Foundation Specialist, LLC I To Whom It May Concern: The purpose of this letter is to confirm pile installation and capacity compliance with the structural re- quirements specified in the L120 Structural Calculation Package and Structural Site Plan dated May 6th, 2021. On June 30'h, 2021, twelve (12) helical piles and eight (8) helical tiebacks were installed by R&R Foundation Specialists (R&R) to stabilize areas of the single-family residence located at 16706 74th PI W, Edmonds, WA 98026. To the knowledge of L120, these piles were installed by R.&R. certified installers in accordance with the cited structural package, ESR-3750. Please refer to the attached drive log and photographs provided by R&R_ Please note that the referenced Structural Calculation Package indicated thirteen (13) helical piles. Helical Pile #1 was removed with approval of L120 in order to prevent damage to the septic system. Please refer to the attached drive log and photographs provided by R&R. The helical piles were installed with maximum pile spacing of 6'-0" on -center, the typical minimum required vertical capacity as determined by L120 is shown in the table below. These demand requirements are as determined and specified in L120's structural calculation package cited above. PILE SPACING & LOAD REQUIREMENTS TABLE MAX O.C. SPACING, ft MIN VERTICAL CAPACITY, kips I PROOF TESTING LOAD, kips PILE # PILE TYPE 200% MIN VERTICAL CAPACITY LOCATION BTWN PILES END OFFSET ALLOWABLE LOADING (MIN.ULTIMATE CAPACITY) 1-6 HELICAL I N/A N/A 9.0 k/PILE 18.0 k/PILE POSTS 7.13 HELICAL I 6'-0" PER PLAN 13.0 k/PILE 26.0 k/PILE TYP EXTERIOR TIEBACK SPACING & LOAD REQUIREMENTS TABLE MAX O.C. SPACING, ft I MIN VERTICAL CAPACITY, kips PROOF TESTING LOAD, kips TIEBACK # TIEBACK 200% MIN VERTICAL CAPACITY LOCATION TYPE BTWN PILES END OFFSET ALLOWABLE LOADING (MIN ULTIMATE. CAPACITY) TYP HELICAL 6'-0" PER PLAN 11.0 k/PILE 22.0 k/PILE TYP EXTERIOR 2 of 6 Pile capacities for the helical piles have been calculated using a Digga MM-10K drive head with a torque correlation factor, Kt, of 9 as prescribed in ESR-3750. A chart showing the resulting capacities is attached to this letter. Per the attached document, an Ideal Foundation Systems 2-7/8" diameter helical pile installed to a minimum pressure of 1,000 psi results in a maximum allowable capacity of 15.7 kips including a safety factor of 2" The results are summarized below: Helical Piles #2-#6: Maximum Demand (allowable): 9.0 kips/pile Available Capacity (allowable): 16.4 kips/pile Helical Piles #7-#13: Maximum Demand (allowable): 13.0 kips/pile Available Capacity (allowable): 16.4 kips/pile Helical Tiebacks #1-#8: Maximum Demand (allowable): 11.0 kips/pile Available Capacity (allowable): 15.7 kips/pile By inspection, the pile capacities of the installed piles exceed the maximum loading demand as determined by L120's analysis. Therefore, the installed piles comply with the structural design/demand. Please contact us if you have any questions. Sincerely, ZT Yang, P.E. L120 Engineering & Design (L120) "-,:va"ii1. i:?`i Mans R. Thurfjell, P.E. L120 Engineering Design (L120) i,wih,,irf;lf i; il•'i f')iit'i:?31?;r. •,'t>i: .$,?'7� • vz� �m mbqq'wmm mmmmmm mmmmmm mmmmmm mmmmmm mmmmmm ,mom■ ■■gym NAMMIN _MMMMOMMMM i= - mmmmmmmmmm mmmmmmmmmm Iimmmmmmmmr lmmrmmmmmmm AIM M L401 125) 636 3313 OIMEngineering.com 1 of 6 Project Name: Foundation Stabilization/Lift — Edmonds Project Number: S201123-1XR Project Location: 16706 74t1i Pl W, Edmonds, W4 98026 Client's Name: Andi Holm, Project Coordinator — R&R Foundation Specialist, LLC (2) ROWS -OF PILES 6`-0" OC MAX W! VERT C10X15.3 LOWER PILES 2'-0" FROM TIGRADE UPPER PILES.6' 0" FROM'T/GRADE -->N Ilk CENTER PILES ON _ EXISTING POSTS R = Exisling Post it 1 ( 3" HQIiCal Pilo 3 518 -3 318. =Helical Tieback,� i � '(2) PILES 3141/4 -3/ _- 1 1 3/6 3t8 ILOI)ATE PILE WITHIN 1' .13 1 FROM WINDOW POSTS LOCATE PILE WITHIN V-0" 2 2 3 I 51 s .. 71 s o nlN FROM Cf)RNEFt: 1 12_ 4 N 8 02 i 0 , CENTER PILE ON WALL SEGMENT 0 0 1/4 0 -5/8 id8 fi3' 5 of 6 MAX Project Name: Foundation Stabilization/Lift - Edmonds Project Number: S201123-1XR Project Location: 16706 74tf' PI ZIT, Edmonds, WA 98026 Client's Name: Andi Holm, Project Coordinator - R&R Foundation Specialist, LLC Subject: 2 - 7/8" 0 Helical Pile - Compression Torque Chart - Digga AIA•1-10K - Ideal Foundation§ stemsb7/8"6 Hetic, i Pile 0.203-inchwalt thickness Soil Ca act >er ESR-3750 DIGGA IOK Drive Head �~Torque,T Torque Correlation Factor, K, Uftfmate Axial Compressfye Copocity,; Allowable Axial Cornpr essive Pressure (psi) (ft fibs) Compresslon (ftJ P. = K,"T (kips) i Copacity, P, =0.5"p" (kips) Soo 1,740 9 15.7 t 7.8 600 2,088 9 18.8 i 9.4 760 2,436 9 2L9 r 11.0 600 2,784 9 25.1 12.5 900 3,132 9 29.2 14.1 100D 3,480- 9 31.3 15.7 110D 3,823 9 120D 4,176� 9 37.6 18.8 130D 4,524 9 40.7 t 20.4 1400 4,872 9 43.8 21.9 15o0 5,220 9 47.0 23.5 1.600 5,568 9 5D.1 25.1 1700 5,916 9 53.2 j 26.6 180D 6,264 9 56.4 28.2 1900 6,612 9 59.5 29.8 2000 6,960 9 62.6 i 31.3 2100 7,308 9 65.8 32.9 2200 7,656 9 68.9 434.5 230D 8,000 9 72.0 36.0 i.) DIGGA 10K olive Head differential pressure display to torque output has been pt:lled from the attached conversion charts provided by 0166A. h.) Per Table 5A of ESR-3750, the maximum i installation torque rating of a 2-7/9 "0 helical pile (0.203-Inch wall thickness) is 8,306 ft'Ibs, Per Ideal Manufacturing, Inc., the maximum installation torque rating of a 2-7/8"0 helical pile {0.203-inch wall thickness) Is 8,000 ft'lbs. Final installation torque shall not exceed the lesser of these limiting values. W.) Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable toad demand as listed in the structural package, but shall not exceed the maximum allowable capacity for.any part of the pile assembly. iv.) Refer to ESR-3750and ideolMonufocturing, Inc. documents for additional information and requirements. v.) Dehnitions_per UR-3750: T = Final installation torque in ft"ibs; the la sttorque reading taken during pile installation, using, for example, the torque reading Instruments connected to the installation equipment. Kt Torque correlation factor per ESR-3750 Pv= Ultimate axial compressive capacity (In kips) of helical pile P. = Allowable axial compressive capacity (In kips) of helical pile vi.) For torque readings between those listed, use the fdlloWing equation to determine the allowable capacity: P. = (T'K,)/2 0.) 1 kip = 1,000 Ibs D_igga - Speed & Torque Chart Model Code: MM - 10K GF: 262 rpm vs Ipm 20 15 10 CD 0 0 20 40 60 80 Flow rate (Ipm) Max. Flow I m 70 Max. Soeed (rr)m)l 16 Output Torque Differential Pressure Display Nm Bar 2,360 34 2,632 41 3,303 48 3,775 55 4,247 62 4,71.9 69 5,191 76 5,663 83 6,135 90 6,607 7,079 97 103 7,651 110 8,023 117 8,495 124 8,967 131 9,438 138 9,910 145 10,382 152 10,854 159 T1,326 166 11,798 172 12,270 f79 12,742 186 13,214 193 13,686 200 44,158 20.7 rpm vs gpm _ ! E 15 i CL I ro 10 i ... t � } 3 °3 5 V) [ 0 I 0 5 10 15 20 Flow rate (gpm) ! i Max. Flow m 18 Max. Speed (rpm) 16 Differential Pressure Display Output Torque PSI ibf-ft 500 1,740 600 21088 700 2,437 800 2,785 900 3,133 1,000 3,481 1,100 3,829 1,200 4,477 1,300 4,525 1,400 4,873 5,221 1,500 1,600 5,569 1,700 5,917 1,800 6,265 1,900 6,613 2,000 6,961 2,100 7,310 2,200 7,658 2,300 8,006 2,400 8,354 2,500 8,702 2,600 9050 2,700 9,398 Z800 9,746 2,900 10,094 3,000 10,442 " IMPORTANT: This chart is based on theoretical values and is provided as a guide only. Digga accepts no responsibility complying with any installation requiring certain torques being reached. You will need to consult an engineer.