APPROVED BLD BLD2021-0344+Architectural_Plan+3.8.2021_6.04.34_AM+2079922GENERAL NOTES GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE AND LOCAL AMENDMENTS. AND ANY APPLICABLE LAND USE CODE. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. SITE WORK 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND WATERPROOFING. 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER APPLICABLE CODE. MECHANICAL AREA CALCULATIONS HEATED AREAS 2ND FLOOR - EXISTING MAIN FLOOR - EXISTING MAIN FLOOR - NEW SQUARE FOOTAGE 768 1248 323 TOTAL 2339 DRAWING INDEX 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL SHEET NO. DESCRIPTION CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2018 IRC, AND LOCAL CODES. PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE Al COVER SHEET, INDEX, GENERAL NOTES WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH A2 ELEVATIONS THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE GARAGE FLOOR. A3 1 ST FLOOR PLAN A4 BUILDING SECTIONS AND MISC. DETAILS THERMAL AND MOISTURE A5 ENERGY CODE INFO S1 STRUCTURAL NOTES/SCHEDULES 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE S2 FOUNDATION PLAN, MAIN FLOOR FRAMING PLAN OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. S3 2ND FLOOR FRAMING PLAN, ROOF PLAN 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION S4 STRUCTURAL DETAILS WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES AND OVER FOOTINGS. FINISHES GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/81, TYPE "X" GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/81' GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. FIRESTOPPING FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL CAVITIES IN LINE WITH STRINGERS. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH NON-COMBUSTABLE MATERIALS. MISCELLANEOUS 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE BEDROOMS. (R315) 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). SYMBOL LEGEND OO CARBON MONOXIDE DETECTOR INTERCONNECTED 110v w/ BATTERY BACKUP C.O. CAN BE COMBINED w/ S.D. O SMOKE DETECTOR INTERCONNECTED 110v w/ BATTERY BACKUP S.D. O EXHAUST FAN (VENT TO OUTSIDE) OKEYNOTE 101 DOOR SCHEDULE SYMBOL 1i WINDOW SCHEDULE SYMBOL Al REVISION- SEE DESCRIPTION IN TITLE BLOCK SIM DETAIL SYMBOL l SIMILAR DETAIL 101 DETAIL NO. SHEET NO. 1 SIM "it BUILDING CROSS SECTION Al DETAIL NO. SHEET NO. Room name — ROOM NAME Know what's b@IOW. Call before you dig. STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO LOCATE ALL UNDERGROUND UTILITIES. FIORE KITCHEN & ENTRY ADDITION & REMODEL 9401 215TH STREET S.W., EDMONDS., WA 98020 APPROVED BY CITY OF EDMONDS BUILDING DIVISION Mar 30 2021 OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES City Of Edmonds Building Department Work ------------------------------------------------------- REMODEL/ADDITION •------------------------------------------------------------------- Address ---------------------------------------------------------------------- 9401 215TH ST SW --------------------------------------------------------------. Owner -- FIORE ----------------------------------------------------- Approved Date , ----------------------------------------------------------- 3/30/2021 Building Official r W. W ofAXLIL --------------------------------------------------- - ------------------------------------ Permit Number: BLD2021-0344 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE V Z N 00 O 00 Z a Q � o IL Y 2 way w O U �c� M CO 'O Z co CD C W E ix 0 W m 0 W a 2 E O V � C + N A N 0 p_ O. O F O 6 U E N Nam .U- L S y O O IJi -mo m o N 2 t.S�Ein O W U o o 3 n y m 0.. g V o m UJ JF N O noU d0:= mO w Omani nao'ia Enm �s o F Zno(n m oF-E@a� W 0 O ix 06 z O I� 0 ULI Q O O N O I� La L z W W J W Z 06 0 z U LU W U N W aw H Q W = z ixW U O LL, 04 w w w � _ z O LL o ¢ a a� iu 0 c 0 .�2 0 W L PROJECT NO. 200903 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. Al RECEIVED Mar 08 2021 mulmulmuo PRIMAT, E�J ��2 '021 5:06:15 PM RTM ELEVATION NOTES Top of Ridge 121' - 6" PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36" WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1) Step 1: Prepare the WRB at the rough opening: install a small section of house wrap below the sill (referred to as an "apron"); alternatively, install self-adhesive pan flashing with split backing (where the release paper backing can be removed incre- mentally) to seal to the house wrap later. Step 2: Install pan flashing: cover the rough sill and extend onto the face of the wall/ WRB. Step 3: Install the window: according to manufacturer instructions. Step 4: Install the jamb flashing: over window flange and pan flashing and extend above the head flange. Step 5: Install the head flashing: over and beyond the jamb flashing (and over the win- dow drip cap if installed). Step 6: Integrate the WRB: Install house wrap shingle -fashion, integrated with the apron, and seal house wrap at jambs and head using sealant (beneath the house wrap) or construction tape. 0 -- COMPOSITION ROOFING AND GUTTERS TO MATCH EXISTING HOUSE. — 2ND FLOOR � 108'-7" 1 1 ST FLOOR PLATE AL c� u z o� X w i C \ SIDING AND TRIMS TO MATCH EXISTING HOUSE. 1 a AveraeGrade 96' - 6" RIGHT SIDE ELEVATION 5 1/4! HEAD FLASHING NOTE: SEE NOTE BELOW DRAWING FOR INSTALLATION `�O5 OF METAL HEAD FLASHING @ THIS AREA L * WEATHER RESISTIVE BARRIER L HYDROGAP DRAINABLE HOUSEWRAP (BENJAMIN OBDYKE) W/ BENJAMIN OBDYKE HYDROFLASHO GP SILL / PENETRATION FLASHING AND BENJAMIN OBDYKE HYDROCORNER SILL FLASHING (APPROVED SUBSTITUTIONS OKAY) IN'- NOTE: 1) INSTALL BENJAMIN OBDYKE HYDROCORNER SILL FLASHING OR EQUIV. @ ALL WINDOW SILL CORNERS 2) INSTALL BENJAMIN OBDYKE HYDROFLASH® GP SILL / PENETRATION FLASHING OR EQUIV. OVER CORNER SHIELD, AS EXTRA PREVENTION FOR LEAKS @ SILL CORNERS FRONT ELEVATION 1/4" = 1'-0" O AREA OF NEW ADDITION I I I I I I I I I I - I I N I I r I I � I I I I - I I I I I I Top of Ridge 121' - 6" 1 ST FLOOR 100, - 0" PLATE 2ND FLOOR PLAT 16'-3" — — — — — — — 116'-3° � =LOOR t 08'-7" 1 — PLATE 07'-9" •O' Housewrap, Rigid cap flashing Flashing tape over head trim 10* to 1 S, C slope AREA OF NEW ADDITION 1 rk Average Grad l REAR E LEVATION HEAD FLASHING NOTE: Flashing AT WINDOW HEAD METAL DRIP tape FLASHING: INSTALL METAL HEAD overtop wind FLASHING @ WINDOWS & EXTERIOR flangew ' DOORS PER THE DETAIL BELOW. " 1/44n. gap beneath siding Head trim Flashing tape over side window flange WINDOW FLASHING 1/4" = 1'-0" d�,AERIAL VIEW 1/4" = 1'-0" 2ND FLOOR � 108'-7" V 1 ST FLOOR PLATE n 107'-9" 1 ST FLOOR 100'-0" V z 00 00 00 0) z E >a Q > y Y = rn CIS w o .N w C O J U �LO rn� z ooN` W im 0 W m J O LUa 2 V + 'gin 4) "a c Jeff ,,, A-lt Z Ned„ C L�� LC GC O z_paCEO Om Q "OE OU Qm 'a 0Nd UO '0-U `2mLOyU NCJ CNm Oa WE EL O.2O Ov°8.0o02 UmUNO W m U E N N L O C d E m � Z O. 2 y` m N d EO ~ LU 0 O LU ix 06 z O H Q � O o N La L z LU LU J LU 06 = z z z U LU W U N W W LU N Q Q LU = Z LU L0 DC u O LL, 04 LU LUw Z � O � LL O ¢ a cu 0 0 .N m O z PROJECT NO. 200903 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A2 RECEIVED Mar 08 2021 mulmulmuo PRIi� 5AT,NTTME}�.'EWW"021 5:09:41 PM R KEYNOTE SCHELDULE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW SYM. N0, FWIDTH HEIGHT AREA WINDOW SCHEDULE WINDOW TYPE U-VALUE COMMENTS 1 ST FLOOR 1 2'- 0" 3' - 0" 6 SF SINGLE HUNG 0.28 2 6'- 0" 5' - 0" 30 SF SLIDER 0.28 3 2'- 6" 3' - 6" 9 SF SINGLE HUNG 0.28 4 2'- 6" 3' - 6" 9 SF SINGLE HUNG 0.28 Grand total 54 SF DOOR SCHEDULE SYM. NO. WIDTH HEIGHT DOOR TYPE COMMENTS 1 ST FLOOR D1 2' - 8" 6'- 8" SINGLE PANEL NOTE: DOORS AND HARDWARE TO MATCH EXISTING D2 3' - 0" 6' - 8" SINGLE POCKET D3 2'- 8" 6' - 8" SINGLE PANEL D4 2'- 10" 6' - 8" SINGLE STORE DOOR (TEMP.) TEMP. GLASS (U=0.28) D5 3' - 0" 6' - 8" ENTRY DOOR w/ SIDELITES (TEMP.) TEMP. GLASS (U=0.28) D6 2' - 4" 6'-8" SINGLE PANEL Draiplft strip � Weathe€Seal trowel -applied membrane 7, Step flashing taped and sealed Kick -out flashing Kick -out and fascia taped and sealed Shingles Wallsheathin"I �ISTjF LOOR 1/4" = 1'-0" KICKOUT FLASHING DETAIL 1/4" = 1'-0" NEW STEP AND LANDING TO GRADE AS SITE DICTATES. V z 00 0 O W z E >a Q > 8 IL =aIT wY w y a '" "�� O J LO U � 0) M(O,O z 00N` W im o W m J O W a 2 H E O V C W � �16 c Z O }t. N O. N C Z5 Z U m O a p J O COL . N Qa m C w := O L~ O O T O r U d C 0 = O J a y' 3 C p O C N N 0 L N U U' U UU«N V `lU0 Ca Nd N EU Oa GC1 CN L UtC6 UNN dWE O O (q O Q O UW O�UT U J U0(mO J H w OZ O N E O H N J W ID O W ix 06 z O LU Q O O N O La L z LU W J W 06 = z z z U LU W U N W W Qw H Q W = Z W L0 04 (U O LU N w w LU � w Z 2 � O � L` O ¢ a cv C O .N N 0 z PROJECT NO. 200903 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A3 RECEIVED Mar 08 2021 mulmulmuo PRIWUT,'TTE.'M 9021 5:1 1:44 PM R 2ND FLOOR PLATE — 2ND FLOOR — 1ST FLOOR PLATE CUT & HANGER PER SCHEDULE/ 1ST FLOOR CRAWLSPAdE EXISTING i i i ATTIC EXISTING FLOOR FRAMING CONTRACTOR TO FIELD VERIFY JOIST DIRECTION PRIOR TO CONSTRUCTION AND NOTIFY DESIGN IF DIFFERENT THAN DRAWN. HANGER PER SCHEDULE ATTACH EXISTING RIM JOIST TO NEW GIRDER TRUSS PER PLAN EXISTING OVER HANG EXISTING ROOF FRAMING EXISTING INSULATION EXISTING INSULATION EXISTING EXTERIOR WALL FLASHING - ATTIC- HANGERPER SCHEDULE 10'-0" 12 14 CRAWLSPACE 6 MIL BLACK V.B. 1 BUILDING SECTION qq SCALE: ,,z,,.o ROOFING PER ELEVATIONS o/ 30# FELT OVER �/16"APA RATED 24/16 SHEATHING ON MANUF. TRUSSES PER PLAN %" GYPSUM CEILING BOARD R-49 BATT OR BLOWN INSUL. 1" AIR SPACE w/ STYRENE INSUL. BAFFLE. EXTEND 24" ABOVE INSULATION VENT BLOCKS w/ (3) 2" dia. WIRE SCREENED VENTHOLES @ EA. BLOCK SOFFIT PER ELEVATIONS CONT. ALUM. GUTTER ON FASCIA BOARD PER ELEVATIONS (2) 2x6 TOP PLATES STAGGER JOINT MIN 48"0 C FRAMING MEMBER ATTACHED TO ,,TOP PLATES PER STRUCTURAL R-21 BATT INSULATION (HEATED AREAS ONLY) 2x6 STUDS @16" O.C. (U.N.O. IN STRUCTURAL) Z" GYPSUM WALL BOARD w/APPROVED P.V.A. VAPOR RETARDER EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER STRUCTURAL PLANS. 3/4" T&G PLY OR EQUIV. SUB -FLOOR GLUED & NAILED TO FLOOR JOISTS PER STRUCTURAL. R-38 BATT INSULATION CAULKING/ SEALANT BEAD AT FLOOR PERIMETER 2x6 BASE PLATE RIM JOIST PER STRUCTURAL P.T. 2x6 BASE PLATE w/ ANCHOR BOLTS PER SHEAR WALL SCHEDULE. 4" TIGHTLINE DRAIN WHERE REQ'D FOUNDATION WALL SIZE AND REINFORCING PER STRUCTURAL PLANS FOOTING SIZE AND REINFORCING PER STRUCTURAL PLANS. 4" PERF. FT'G DRAIN.WRAP IN FILTER FABRIC w/ GRAVEL OVER. 0 EXISTING 2ND FLOOR WALL EXISTING ROOF FRAMING EXISTING FLOOR FRAMING 2ND FLOOR 1ST FLOOR PLATE BEAM PER STRUCTURAL PLANS HANGER PER STRUCTURAL PLANS (2) 2x4 TOP PLATES STAGGER JOINT MIN. 48"O.C. HEADER PER STRUCTURAL PLANS NEW ENTRY DOOR REMOVE EXISTING ENTRY WALL P.T. 2x6 BASE PLATE w/ ANCHOR BOLTS PER SHEAR WALL SCHEDULE. NEW FOUNDATION PER STRUCTURAL PLANS 3/4" T&G PLY OR EQUIV. SUB -FLOOR GLUED & NAILED TO FLOOR JOISTS PER STRUCTURAL. R-38 BATT INSULATION NEW FLOOR FRAMING PER STRUCTURALPLANS 1ST FLOOR R-49 BATT OR BLOWN INSUL. NOTE: WALL NOT SHOWN AT CRC SECTION BUT SHALL BE 2x4 WITH 3.5" CLOSED CELL INSULATION (R °a a �_J I a� a 2 BUILDING SECTION. A4/) SCALE: 1 /2" = 1'-0" Lu _ w Lu 0 0 0 LL. Lu W Lu z V Lu V o ~ z Q w Q LL Lu o u 0 � z L O LuLuw Q C 0 Z C ALL o� aW 0 �L 0 0 z PROJECT NO. 209003 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: RECEIVED Mar 08 2021 PRI� "'TN,ENrl�L021 5:14 PM GENERAL NOTES All design and construction shall conform to the requirements of the International Building Code 2018 Edition. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for all the following: Structural steel, steel canopies, glued -laminated members and pre -manufactured wood members. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. DESIGN LOADS LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 7 L = 40 PSF (Residential) SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Factors: Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7-10 Ch. 28 (Envelope Procedure) with the following factors: Exposure Category = B Iw = 1.0 Velocity (3 sec) =110 mph (ult) Kzt = 1.0 Design wind pressured for determining forces on components and cladding are determined in accordance with ASCE 7-10 Chapter 30. SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section 12.8 with the following factors: Risk Category = II Ss = 1.27 Site Class = D S1 = 0.496 Design Category = D SIDS = 0.845 R = 6.5 (wood shear wall) SD1 = 0.497 Ie = 1.0 Cs = 0.130 (ult.) FOUNDATIONS Concrete foundations shall bear on stiff, competent, undisturbed native soil. Prior to construction, the contractor shall obtain confirmation from the Building Official, or a Washington State licensed Geotechnical Engineer, that the native soil at this project is adequate to support the following bearing pressure: Allowable bearing pressure used for structural design = 2000 psf (assumed) Where footings must bear on structural fill due to inadequate soil conditions, the fill shall be mixed and compacted in accordance with specifications provided by a Geotechnical Engineer licensed in the State of Washington. Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the Building Official prior to excavation. CONCRETE Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete for Buildings." CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs but shall conform to ASTM C 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water-soluable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. WOOD SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb(psi) Wall Studs Hem Fir Stud 675 Plates & Planks Hem Fir #2 850 Joists & Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood exposed to weather or water or in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FN intersections Truss to top plate 3" x 0.131" 4 TN *EN = end nail, FN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg 7/16" 32/16 C-D INT APA with Exterior Glue (CDX) Roof Shtg 15/32" 32/16 C-D INT APA with Exterior Glue (CDX) Sub Floor Shtg 3/4" 48/24 T&G C-D INT APA with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Symbol Species Fb E GLIB24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLIB24F-V8 DF/DF 2400/2400 psi 1,800,000 psi ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12" member depth): Symbol Fb E PSL 2900 psi 2,000,000 psi LVL 2600 psi 2,000,000 psi LSL 1700 psi 1,300,000 psi Versa -Lam (1%4-2%") 2800 psi 2,000,000 psi VersalLam (31/2" & wider) 3100 psi 2,000,000 psi PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer licensed in the State of Washington, who is regularly engaged in the design of plate -connected wood trusses. Truss design shall be accordance with IBC Section 2303.4. Trusses shall be design for the following superimposed dead loads: top chord bottom chord total roof trusses 10 psf 5 psf 15 psf In addition to dead loads, the design shall include the live, wind, snow loads as identified in the "Design Loads" section of these drawings, and the snow drift, sliding and unbalanced loads per ASCE7 Chapter 7. The truss design shall include concentrated and axial loads shown on framing plans and hanger schedules in these drawings. Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings. Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall be supplied with tapered hardwood shimming so that every chord bears on the full width of every support, without notching the truss members. The truss manufacturer is responsible for ensuring the bearing seat does not exceed the sill plate capacity of the supporting element. RECOMMENDED INSPECTIONS The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: -Footings bear on competent native soil per the "Foundations" section above -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule -Shear wall hold-downs TYPICAL DETAILS In addition to the details and schedules on the framing plans, those noted as "Typical" shall be Ised throughout the structure as applicable. STRUCTURAL NOTES ""'7D FRAMING PER PLAN VARIES. !0/S2 FOR CONNECTIONS AND RING NOT SHOWN ILL PLATE w/ ANCHOR BOLTS ) WASHERS PER SHEAR WALL EDULE. MINIMUM ANCHOR T EMBEDMENT = 7". DRIZ. AT 18" o.c. AND (2) AT OF WALL ERT. DOWELS AT 24" o.c. RNATE HOOK AT BASE FING PER PLAN TYPICAL CONCRETE FOUNDATION 1 EMBED ALL NEW STEM WALL AND FOOTING REBAR INTO EXISTING FOUNDATION. DRILL AND EPDXY 4" MIN. EXISTING STEM WALL Z EXISTING FOOTING / NEW STEM WALL EMBED ALL NEW STEM WALL � \ AND FOOTING REBAR INTO EXISTING FOUNDATION. DRILL NEW AND EPDXY 4" MIN. FOOTING NEW FOUNDATION TO EXISTING 1 4 SHEAR WALL PER PLAN EDGE NAILING #4 AT 24" o.c. ALTERNATE z DIRECTION W #4 CONT. TOP AND BOTTOM AND 18" o.c. EACH FACE 00 m N CRIPPLE STUDS AT 16" O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUD(S) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN 10d AT 6" o.c. 2x PT SILL PLATE w/ BOLTS PER SHEAR WALL SCHEDULE 2x4 FLAT BLOCKING AT 48" o.c. -EXISTING RIM JOIST 10d AT 6" o.c. 2x10 CONT. WITH 16d AT 6" o.c. 1' 0" EXISTING FOUNDATION SECTION 1 7 SOLID BLKG MATCH WIDTH OF BEAM/GIRDER TYPICAL HEADER DETAIL I 10 VERIFY EXISTING 2x RIM JOIST EXISTING FLOOR FRAMI� EXISTING FOUNDATIC POST BETWEEN JOISTS OOR BOUNDARY AILING DNT. 2x BLOCKING (ITH 16d AT 6" o.c. W FLOOR JOISTS AND ANGERS PER PLAN SINGLE REINFORCING NOTES: 1. VERTICAL REINFORCING NOT SHOWN FOR CLARITY 2. SEE STRUCTURAL NOTES FOR CLEAR COVER 24" #4 x 24" MATCH HORIZ REINF. 24" 44 x 24" MATCH HORIZ 1EINF. #4 x 24" MATCH HORIZ REINF. DOUBLE REINFORCING SECTION I Z I TYPICAL CONCRETE WALL AND FOOTING CORNER I $ JF 'LP 5d 5d )R. PE CONNECTION )LAN FING PER PLAN POST AT JOISTS DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES NO 10d 6" OC 12" OC 6" OC SUB-FLR NO 10d & GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED PANELJOINT TF it �l: I 17 11 11 i I; IJ [I IJ I: n BOUNDARY :1 11 n 11 1I IJ 11 Id ;f NAILING 11 11 t li 11 TOP PLATE Ij I: Ij l 1J IJ BLOCKED CONTINUOUS :I dl: n 11 IJ IJ Ij 1114 "OTHER" PANEL PANEL101NT 11 11 EDGE NAILING fl ]I. H �I IJ IJ INTERMEDIATE JOIST/TRUSS NAILING , DIAPHRAGM DETAIL TYPICAL DIAPHRAGM NAILING 1 $ II II I I ROOF TRUSSES/ I I RAFTERS BELOW I L I I 2x6 BLOCK BETWEEN ROOF TRUSSES BELOW W/ I I (2) 16d EA END I I I I � I I I I i 2x6 PLATE W/ (2) 16d I I INTO EA ROOF TRUSS I I i BELOW I�I� I I I I I I 2x4 RAFTERS @ 24"o.c. POST DOWN TO ROOF i I I TRUSS BELOW AT 24" o.c. I I I I I I I I I I I I i I I TYPICAL ROOF OVERFRAMING I 1 1 VG TOP Pl. PC POST J FLOOR POST )LAN 5d FING FLOOR BEAM )R 6x6 DF#2 POST FCH BEAM WIDTH) :2) SIDES WITH 2RETE NAILS FING PER PLAN POST AT BEAM SECTION 1 6 10% 1n111 Kroll c rnru cmr NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE 1 9 12 Ross Engineering Design Inc ryan.ross@rossengineer.com 2.18.2021 ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W _ 11w W o 0 O UJ W W z U Z U o H Z Q w Z W W o N Z he v O w O w w 0 3:C) 0 CL LL O Q w m R 0 c 0 g �L N m 0 C Z FILE/ NO. 21002 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: ;i ECEI Mar 08 2021 CITY OF EDMONDS PFN�E 2 / 16 / 2021 POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x_ STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (3) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (4) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 6x6 DF#2 (4) 16d NAIL (2) A34 P-06 P-07 NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE A B C i GARAGIE SLAB ° EXISTING MAIN FLOOR FRAMING. BEAM SCHEDULE SYM. BEAM BM-01 4x8 DF#2 OR BETTER BM-02 3.5"x9" GLULAM BM-03 5.25"x9.25" PSL BM-04 3.5"x9.25" PSL BM-05 FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE %2' dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A 3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL & HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16"x24". (R408.4) • PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS. (R406.3.2) • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. FOUNDATION VENT CALCS. (R408.1) PROVIDE 1 SQ. FT. OF VENTILATION FOR EVERY 300 SQ. FT. OF CRAWLSPACE. FOUNDATION VENTS SHALL BE EXTRUDED, LOAD BEARING 16"x8" VENTS. PROVIDE A MINIMUM OF (1) FOUNDATION VENT WITHIN T-0", BUT NOT WITHIN THE FIRST V-0" OF EACH CORNER OF CRAWLSPACE. ASSUMED VENTS ARE MIN. 15.5"x6" AND HAVE A NET FREE VENTILATION AREi OF .48 SQ. FT. NEW FOUNDATION VENT CALCULATIONS CRAWLSPACE AREA 297 SQ FT NET VENTILATION AREA/ 300 SQ FT 0.99 NET AREA NUMBER OF VENTS REQ'D NETAREA/ 0.48 3 OPTIONAL POWER VENT CRAWLSPACE HEIGHT 3 59.4 CFM HANGER SCHEDULE SYM. HANGER H-01 LU210 / LUC210 H-02 HU410 MAX NAILS H-03 HUCQ610-SDS NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER FOUNDATION PLAN. SCALE: 1 /4" = V-0" A B i EPDXY DOWEL ALL SHORT WAY FOOTING BARS INTO EXISTING 10'-0" 04 tAWLSPACE 6 MIL. BLACK V.B. I] — C J -O LEGEND STEM WALL FOOTING EXISTING STEM WALL EXISTING FOOTING CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F-01 "16'W" CON'T. (2) #4 CON'T. F-02 24"x24"x8" (2) #4 EA. WAY F-03 *36"x30"x8" (4) #4 EA. WAY F-04 "42"x%'W" (2) #4 LONG WAY (4) #4 SHORT WAY F-05 "12" WIDE THICKENED EDGE SEE 7/S1 F-06 '24"x24"x8" (2) #4 EA. WAY NOTE: "EXTERIOR FOOTINGS SHALL BE MIN. 18" BELOW GRADE AND REST ON BEARING SOIL. Ross Engineering Design Inc ryan.ross@rossengineer.com 2.18.2021 ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W _ w W 0 0 0 LL. Lu W Lu z U Lu U 0 z Q w QLu W o Zoe Lu 0 LU w_ N Z `L O w Ow z oZ. � LL o Q w c 0 a �L v 0 z PROJECT NO. 200903 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S2 RECEIVED Mar 08 2021 L;PR� V"'TMENl9�2021 8:39 AM EXTERIOR WALLS NOT MARKED SHALL BE sW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET S4 FOR SHEAR WALL SCHEDULE AND TYPICAL SECTIONS MAIN FLOOR SHEARWALLS SCALE: 1/8" = 1'-0" >M U) I I _'_====�v_____________________ i 51 POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P—Ol (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x_ STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (3) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (4) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 6x6 DF#2 (4) 16d NAIL (2) A34 P-06 P-07 NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE II II ROOF PLAN NOTES II I I II I I __T_______T_�i li • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. -- — -- --- -- -- I II II II II II II II II II II I II II I II II II II II II II I II II II II II I II II I II II LF---------------- I L L___ _ u III � EXISTING TRU SES II I @24"O.C. II II II II II II II II II II II II II � II I I GE- I II I II II II II � II I I II II II I II l I I II II II II Ii �I II II I I I II II II I II I II II II II LJ l I II I I l u LJ II I II I I I I I� lI J rl n Qw I C --------------- 'II------------ 2 NOTE ! NO CHANGES MADE TO UPPER ROOF ---------------------- 1 UPPER FLOOR ROOF PLAN SCALE: 1/4" = 1'-0" FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. • FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. • SHADED AREAS INDICATE OVER -FRAMING. • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVER ALL SUPPORTS. • PROVIDE MIN. 22"x30" ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. • 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. • ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING ROOMS. ATTIC VENTILATION CALCULATIOl' ATTIC VENTILATION (R806.1 & 806.2) PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 150 SQ. FT. ATTIC AREA. EXCEPTION: PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. I ATTIC SPACE WHEN NOT LESS THAN 40% AND NOT MORE THA OF THE REQUIRED VENTILATION AREA IS PROVIDED BY VENTILATORS LOCATED WITHIN THE UPPER PORTION OF THE OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF SPACED MEASURED VERTICALLY WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VEN WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBER; CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS. INSTALLATION OF MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. NEW ROOF VENT CALCULATIONS ROOF AREA 297 SQ FT REQUIRED ROOF VENTILATION AREA/ 300 0.99 SQ FT 40-50% IN UPPER & LOWER ROOF ROOF VENT AREA / 2 0.50 SQ FT VENT BLOCKS IN EAVES BLOCKS = AREA/ 0.074 7 ROOF VENTS IN UPPER 40-50 % OPTION 1: AF50 ROOF JACK = AREA/ 0.333 2 OPTION 2: (ridge vent) CORAVENT V300 = AREA/ 0.094 5.3 FEET BEAM SCHEDULE SYM. BEAM BM-01 48 DF#2 OR BETTER BM-02 3.5"x9" GLULAM BM-03 5.25"x9.25" PSL BM-04 3.5"x9.25" PSL BM-05 Q Q Q 2ND FLOOR FRAMING SCALE: 1/4" = 1'-0" HANGER SCHEDULE SYM. HANGER H-01 LU210 / LUC210 H-02 HU410 MAX NAILS H-03 HUCQ610-SDS NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER ER NOTE ! 3 NOT CALLED LAN SHALL BE: O� BM-01 Q� GEND SSES SSES (TOP CHORD) R FRAMING LS UNDER LS/ FIXTURES OVER DERS & BEAMS DR PERIMETER 'ER ROOF LINES ,TING ,TING WALLS UNDER ,TING HEADERS & BEAMS OVAL Ross Engineering Design Inc ryan.ross@rossengineer.com 2.18.2021 yPNN.RoS � pF WASy�N S �i Z J B# 21 02 46411 �FGISTER�� sS,ONALt ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W _ w W 0 0 0 LL. W W �j z U Lu U 0 ~ z a w QLu W o ZoeN Louw Lu 0 Z w `L O Ow Z. z E 0 in � L` Q Lu w 0 a rn d 6 z PROJECT NO. 200903 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S3 RECEIVED Mar 08 2021 PRILulvlulN � "'"EN7NT2021 8:40 AM 1 EXISTING STUD WALL. SHEATHING TO REMAIN FULL HEIGHT. HANGERS PER PLAN VERIFY EXISTING 2x10 FLOOR JOISTS PERPENDICULAR TO GIRDER TRUSS ATTACH EXISTING LEDGER TO GIRDER TRUSS WITH SDW22438 TOP AND BOTTOM AT 9" ox. EXISTING STUD WALL. SHEATHING TO REMAIN FULL HEIGHT. LU210 HANGER EACH BLOCK 2x10 BLOCKING AT 16" ox. EXISTING 2x10 FLOOR JOISTS ATTACH EXISTING LEDGER TO GIRDER TRUSS WITH SDW22438 TOP AND BOTTOM AT 9" ox. 11 TYPICAL SHEAR WALL SCHEDULE NUMBER OF SHEAR WALL STUD/BLKG. SILL PLATE / SOLE PLATE FRAMING ANCHOR TO NAIL/SCREW SHEATHED EDGE AT ADJOINING 67 SYMBOL SHEATHING SIDES 1 NAILING PANEL EDGES s SIZE CONCRETE s TO RIM JOIST SHEAR CLIPS SWl 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 3"x.131" NAIL 3"x.131" TOENAIL @ 48" OC @ 6" OC @ 6" OC $ SW2 5/8" DIA. AB 161BOX NAIL LTP4 @ 24" OC SEE SW3 STRUCT 1 8d @ 4" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 18" OC NOTES @ 32" OC @ 4' OC SW4 1 8d @ 3" OC z 3x OR DBL. 2x4 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 14" OC @ 24" OC @ 3' OC FSW57 1 8d @ 2" OC2 3x OR DBL. 2x4F2X 5/8" DIA. AB 16d BOX NAIL LTP4 @ 10" OC @ 18" OC @ 2.5" OC SHEAR WALL SCHEDULE NOTES 1. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE. 2. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS %". 3. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL HORIZONTAL ADJOINING PANEL EDGES. 4. 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 16d NAILS MATCHING EDGE NAIL SPACING. STAGGER PER NOTE #2 5. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"0"x.223" STEEL PLATE WASHERS. LOCATE EDGE OF WASHER WITHIN %2" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE DIAGONALLY SLOTTED 1.75" MAX. 6. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING. 7. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS. 8. SEE DETAIL (TOP FAR RIGHT) FOR TYPICAL TOENAIL ROOF BOUNDARY NAILING (2) 16d TO EACH STUD GIRDER TRUSS PER PLAN VERIFY EXISTING 2x10 LEDGER SECTION 1 7 ROOF BOUNDARY NAILING (2) 16d TO EACH STUD 2x4 BLOCKING AT 48" o.c. EXISTING ROOF TRUSSES ROOF SHEATHING PER STRUCTURAL NOTES ROOF BOUNDARY NAILING 2x BLOCKING PANELS PROVIDED BY TRUSS MANUFACTURER SHEAR WALL SHEAR CLIPS EDGE NAILING SHEAR WALL PER PLAN ROOF TRUSSES PER PLAN H1 CLIP EACH TRUSS SHEAR WALL AT RAISED TRUSS HEEL 1 $ SOLE PLATE NAIL/ EDGE EXTEND SHEAR WALL SHE, CONT. OVER RIM JOIST. I BREAK AT SOLE SHEAR WALL EDGE NAIL RIM JOIST AND SIL FLOOR BOUNDARY NAILING PER DIAPHRAGM SCHED 2x SILL PLATE FLOOR JOIST 'E: SIMILAR SECTION PER i4 FOR INFORMATION SHOWN GIRDER TRUSS PER PLAN VERIFY EXISTING 2x10 LEDGER SECTION 12 ALTERNATE SHEAR FLOW AT LOWER FLOOR 13 171 118 SOX SHEAR CLIPS PER SHEAR WALL SCHEDULE WHERE APPLICABLE TYP. SQUASH BLOCKS IN RIM JOISTS AT ALL POSTS AND HOLD-DOWNS, ALL LEVELS. SEE TYPICAL POST BLKG. DETAIL TYP. ANCHOR TYPE HOLD-DOWN W/ ANCHOR ROD PER HOLD-DOWN SCHEDULE TYP. 8d AT 12" ox. NAILING AT ALL INTERMEDIATE SUPPORTS PANEL EDGE NAILING TYP. SILL/SOLE PLATE W/ ANCHORS PER SCHED. TYP. ANCHOR TYPE HOLD-DOWN PER PLAN WHERE APPLICABLE. SEE SCHEDULE FOR ANCHOR ROD TYP. ROOF BOUNDARY NAILING CONT. 2x BLKG WITH VENTING PER ARCHITECTURAL. SEE 8/S4 FOR ALTERNATE AT RAISED TRUSS HEELS. EDGE NAILING SHEAR WALL PER PLAN TYP SOLE PLATE NA EDG FLOOR BOUNDAR 2x I SHEAR WALL SHI OR ALTERNATE HEAR WALL ID Op� N SW HOLD-DOWN ID SHEAR WALL KEY 0° I J III III III 11 III III III I: LL - - -I r - - - - - 17 - -.Fr - - I'I I I I I I I I•I I: BLKG PER SCHED AT HORIZ. TYPICAL TOENAIL I I_ a I _ I I _ _II _ PANEL JOINTS w/ EDGE _ _ NAILING BOTH SIDES OF I I I I I'I II II II II I I j l I II II• JOINT TYP. I I I I I LOCATE VERTICAL PANEL I I I I I I JOINT ON STUD w/ EDGE NAILING BOTH SIDES OF JOINT MIN (2) STUDS AT EACH HOLD-DOWN UNLESS NOTED OTHERWISE PER PLAN OR POST SCHEDULE TYP. STRAP TYPE HOLD-DOWN SEGMENTAL SHEAR WALL PER PLAN TYP. ROOF SHEATHING PER STRUCTURAL NOTES ROOF TRUSSES PER PLAN H1 CLIP EACH TRUSS 2x6 STUDS AT 16" ox. TYP PRESSURE TREATED SILL PLATE PER SHEARWALL SCHEDULE. BOLT EMBED = 7" MIN. FLOOR JOISTS PER PLAN FOUNDATION PER PLAN FRAMING PERPENDICULAR TO WALL ROOF BOUNDARY NAILING SHEAR WALL SCHEDULE AND NAILING DETAIL 1 5 ROOFBOI'"'^""" SF c SHI SOLE PLATE NAIL/SCREW EDGE NAILING FLOOR BOUNDARY NAILING 2x RIM JOIST SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 13/S4 FRAMING PARALLEL TO WALL (4) 10d TO BLKG PRESSURE TREATED SILL PLATE PER SHEARWALL SCHEDULE. BOLT EMBED = 7" MIN. FLOOR JOISTS PER PLAN 2x BLKG AT 48"oc FOUNDATION PER PLAN WALL SS TYPICAL STRUCTURAL WOOD WALL/SHEAR WALL ASSEMBLIES 115 DRAG TRUSS PER PLAN ALIGNED OVER SHEAR WALL SHEAR WALL SHEAR CLIPS 2x BLOCKING AT 48"o.c. EDGE NAILING 2x4 OR 2x6 STUDS AS INDICATED PER PLAN AT SHEAR WALL PER PLAN TYP 16" ox. SECTION 119 20 Ross Engineering Design Inc ryan.ross@rossengineer.com 2.18.2021 ► N. P 21 02 46411 �FGISTVE SS�ON AL ECG ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN W _ lC W 0 0 0 U. ui W W W z V ui V o z Q w z W W o N Z w w "0 Or w0 o o 0 � LL O Q Lu m 0 �L N d 0 Z 61111111111111 FILE/ NO. 21002 DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: ;i ECEI Mar 08 2021 CITY OF EDMONDS PFffif8'A FE 2 / 16 / 2021