Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD BLD2021-1458+PLANS _10.22.2021_11.11.57_AM+2478170
PERMITTING & DEVELOPMENT BUILDING DIVISION 121 5th Avenue N P: 425.771.0220 www.edmondswa.gov APPROVED BY PLANNING 111a"- /V,�- Oct 26 2021 APPROVAL STAMP PAGE PLEASE KEEP WITH THE PLANS City Of Edmonds Building Department Work (1) SIGN Address 22618 HWY 99 #113 -------------------------------------------- Owner STATE FARM -------------------------- ______________________________________ Approved Date: 10/27/2021 r Building Official L7 W. M pfka-&L Permit Number BLD2021-1458 No commercial sign shall be illuminated after 11:00 RECEIVED p.m. unless the commercial enterprise is open for OBTAIN ELECTRICAL business and then may remain on only as long as PERMIT FROM Oct 25 2021 STATE LABOR & CITY OF EDMONDS the enterprise is open INDUSTRIES DEVELOPMENT SERVICES DEPARTMENT APPROVED ALL WORK SUBJECT PLANS MUST BE TO FIELD ON JOB SITE INSPECTION FOR CODE COMPLIANCE NOTE: This Stamp page must remain with the city approved plans at all times. Failure to have this Stamp page with the City approved plans could result in delay of the inspections including the FINAL inspection. If lost please contact the city as soon as possible to find a solution. Thank You. o qleMap 22618 Hwy 99 AM 9 C OW..- BLD2021-1458 I SIGN LOCATION a Y+, RECEIVED Oct 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT r- b 1, a 3. VIM :STATE FARM MARK CHOI { - 22618 HWY 99 SUITE 113 W JEDMONDS WA 98026 x, ZONE: CG PARCEL# 27043000404800 Imagery ©2021 Google, Imagery ©2021 Maxar Technologies, U.S. Geological Survey, Map data ©2021 50 ft itpteF-arq? 18" High Letters / 3-Oval Symbol is 19.4" High x 29.4"Wide; (11'2.6" Overall Length) CL18 Red. (18.75 sq. ft.) LED Illuminated; Raceway Mounted; Raceway Color Match SW6072 Versatile Gray NOTE: Install does not include facade repair (patch/paint of existing wall). NOTE: Sign does not ship with a photo cell or timer. Agent is responsible to have a timer installed at the breaker by a local licensed electrician if needed. NOTE: Agent is responsible to have a dedicated, adequate run to sign location by a local licensed electrician (120V, 20 amp). Installers to perform final connect within 5'of sign only. Such wiring must have the approval of the National Board of Fire Underwriters or the municipal department having jurisdiction. Customer: STATE FARM Description: 18" Letterset Project No: 458344 A I Scale: Date: 10/12/2021 Drawn By: TAJ Location & Site No: 22618 Highway 99, Suite 113 Revised: Edmonds, WA 98026 SF97836 Revised: SW 7005 (or match) Customer Approval: Graphics and colors on file will be used unless otherwise specified by customer. Please review drawing carefully. By signing below, you agree to graphics as shown above, and to location of sign as shown. Please return signed copy back to Everbrite. CUSTOMER SIGNATURE DATE LANDLORD SIGNATURE DATE 11'-2 1/2" 2'-5 3/8" RED LED MODULE 4'-10" RACEWAY FRONT VIEW SCALE 1:16 6IN 7/16" DIA. MOUNT HOLE RACEWAY FLANGE 0 0 RACEWAY FRONT VIEW SCALE 1:16 FACES 8'-6 1 /4' SEAL ALL PENETRATIONS! CONTINUOUS BLOCKING (AS REQ'D) (10) 3/8" DIA. FASTENER/HARDWARE (TYPE & LENGTH T.B.D. BY INSTALLER ON SITE) SIGN FACE (10) PVC SLEEVE @ COMPRESSIBLE WALL FINISH (IF REQ'D) CONDUIT TO REMOTE POWER SOURCE (INSTALLER TO PROVIDE UL LISTED CONDUIT & FITTINGS, AND MOUNTING HARDWARE) (1) 7/8" DIA. ELECTRICAL ROUTE HOLE (1) POWER SUPPLY MOUNTED INSIDE RACEWAY ELECTRICAL SPECS. (1) LED 60W 12V POWER SUPPLY LED MODULE 0.7 AMPS EACH (INPUT) TOTAL 0.7 AMPS @ 120 V WEEP HOLE(S) *USE (1) 20 AMP CIRCUIT 7/8" DIA. ELECTRICAL INLET ON BACK OF RACEWAY WALL FINISH OVER SHEATHING (INSTALLER TO IDENTIFY TYPE & THICKNESS) ® WALL FRAMING (T.B.D. BY INSTALLER ON -SITE) NOTE: DETAIL SHOWN MAY NOT REFLECT 0ho o THE ACTUAL WALL CONSTRUCTION AS O ° a WALL TYPES VARY PER SITE. IT IS THE INSTALLER'S RESPONSIBILITY TO IDENTIFY THE ACTUAL CONSTRUCTION AND ADAPT o• THE INSTALLATION ACCORDINGLY. WEEPHOLES AT ALL LETTERS/LOGO 6'-4 1/2" RACEWAY 4" 5" WALL MOUNTING DETAIL SCALE 1:8 GENERAL NOTES INSTALLER TO PROVIDE COMPLETION PHOTOS OF MOUNTING/CONNECTION POINTS, WIRE ROUTING AND OVERALL ELEVATION. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRIC CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. INSTALLER TO BE SURE SIGN IS PROPERLY INSTALLED, CONNECTED AND GROUNDED. 1. OPEN PACKAGING CAREFULLY AND INSPECT FOR DAMAGE. IF DAMAGE IS FOUND, CLAIM MUST BE FILED WITHIN 15-DAYS WITH SHIPPING AGENT. 2. DETERMINE SIGN LOCATION AND TAPE UP THE PROVIDED TEMPLATE ON THE SURFACE TO WHICH IT WILL BE INSTALLED, RECEIVE CONFIRMATION FROM CLIENT OR CONTRACTOR. 3. LAYOUT AND PRE -DRILL ALL MOUNTING AND ELECTRICAL HOLES REQUIRED FOR MOUNTING THE RACEWAY TO THE WALL. 4. FILL ALL HOLES WITH SILICONE PRIOR TO MOUNTING THE SIGN. 5. ATTACH THE HORIZONTAL BLOCKING BEHIND WALL FRAMING SO ALL CONNECTION POINTS HAVE SUPPORT. 6. ALIGN RACEWAY TO MATCHING PRE -DRILLED HOLES WHILE INSERTING FASTENERS THROUGH RACEWAY, WALL AND BLOCKING. FASTEN WITH HARDWARE. USE PVC SLEEVES TO PROTECT BUILDING FINISH SYSTEM OVER SHEATHING. 7. MAKE FINAL ELECTRICAL HOOK UP TO PRIMARY WIRING OF POWER SUPPLIES THROUGH DRILLED ELECTRICAL HOLES. 8. TEST LIGHT FOR PROPER FUNCTION AND ILLUMINATION. 9. PERFORM TOUCH-UP AS REQUIRED 10. CLEAN INSTALLATION WORK SITE OF ALL EXCESS MATERIALS AND DEBRIS. DO NOT DISCARD ANY MATERIAL OR DEBRIS INTO ON SITE DUMPSTERS. ° ° ° ° ° E�rbrite ao 000O0� 000 O 0000 4949 SO. 110TH ST. .000 O000 P.O.BOX p0009000000'PROPERTY "° pOpOp °o GREENFIELD, WI 53220 ° ° @ 414-529-3500 INSTALLATION DRAWING DRAWN BY sA� STANDARD DRAWING TITLE STATE FARM 19 318" LED LOGO 118" LED CHANNEL LETTERS ON RACEWAY, INLINE, RED, STANDARD WALL DATE 3-6-15 THESE DRAWINGS ARE THE EXCLUSIVE OF EVERBRITE, LLC. USE H- OR DUPLICATION IN ANY MANNER WITH- OUT EXPRESS WRITTEN PERMISSION OF EVERBRITE, INC. IS PROHIBITED. CHECKED BY RHB PROJECT NO. ^/ /y�� 7 3 L 5 V / 4 DRAWING NO. I N 04 951 B REV A A 3-6-15 SAJ RHB RELEASED FOR INSTALLATION DATE 3-6-15 SCALE AS SHOWN REF E003768P REV DATE BY CHK DESCRIPTION