Loading...
FIR2021-0149+Fire_Sprinkler_Equipment_Specification_Sheets+12.20.2021_11.29.53_AM+2582623Availability: Americas Bulletin 213 May 2021 ReliablE � Product Description RASCOFLEX° Sprinkler Connections are intended to connect a branch line to a sprinkler using a flexible stainless steel hose assembly. RASCOFLEXO Sprinkler Connections are suitable for use in suspended and hard ceiling applications such as T-Bar ceiling grids, wood, metal stud, or hat furring channel hard lid ceilings. Every package contains one (1) fully assembled stainless steel flexible sprinkler system complete with hose, branch line connection, and sprinkler connection, as well as the pre - assembled bracket assembly to attach to the ceiling. RASCOFLEXO Sprinkler Connections are designed for use in hydraulically calculated wet, preaction, or dry sprinkler systems per NFPA 13, 13R, 13D, and FM Global Loss Prevention Data Sheets. Technical Data Maximum Working Pressure FM: 200 psi (13.8 bar) UL: 175 psi (12.1 bar) Maximum Working Temperature 300°F (149°C) Connections Inlet/Branch Line 1" NPT Outlet/Reducer 1/2" or 3/4" NPT Minimum Allowable Bending Radius UL: 3" (76 mm) FM: 7" (178 mm) Maximum Number of Bends See Friction Loss Chart Maximum K-Factor 1/2" Outlet 5.6 (80 metric) 3/4" Outlet 14.0 (200 metric) Maintenance RASCOFLEV Sprinkler Connections should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Patents RASCOFLEV Sprinkler Connections may be covered by one or more of the following US Patent Nos. 10,173,088 and 10,328,296. Listings and Approvals FM Approved Class No. 1637 (FM) UL Listed and UL Certified for Canada to ANSI/UL 2443 (cULus) RASCOFLEXO Sprinkler Connections RECEIVED Dec 20 2021 cULus Listed, FM Approved CITY OF EDMONDS DEVELOPMENT SERVICES F I R2021-0149 DEPARTMENT RASCOFLEXO Sprinkler Connections Ordering Information Specify: Model Name • Model RFB Nominal Hose Length • 24" (610 mm) • 31" (790 mm) • 40" (1015 mm) • 48" (1220 mm) • 60" 1525 mm) • 72" (1830 mm) Reducer Outlet: 1/2" NPT or 3/4" NPT Reducer Type Standard: • 6-1/8" (155 mm) straight Optional: • 4-5/16" (110 mm) straight • 5-5/16" (135 mm) straight • 11-3/4" (300 mm) straight • 5-5/8" (143 mm) elbow • 7-3/8" (187 mm) elbow Bracket Assembly Length • 24" (610 mm) standard • 48" (1220 mm) optional Accessories • See Table F www.reliablesprinkler.com Bracket Dimensions 28" [711 ] for 24" bracket or 52" [1320] for 48" bracket IF IF N N � O T =o r 0 'Co LO Nominal 1-11/16" (43mm) ceiling grid shown for reference only. Verify actual ceiling grid dimensions and ceiling tile reveal prior to ordering. 4� v� v Reducer Dimensions 0 -ro v CO 4-5/16" (110 mm) Straight m0 =o LO v m 5-5/16" (135 mm) Straight LO O CO CO77 6-1/8" (155 mm) Straight Standard 0 0 0 co � - N _ p u =co O co 11-13/16" (300 mm) Straight r `c =� m 5-5/8" (143 mm) Elbow Lo � r r` co 7-3/8" (187 mm) Elbow Bulletin 213 May 2021 Page 2 of 8 www.reliablesprinkler.com Installation Dimensions Nominal 1-11/16" (43mm) ceiling grid shown for reference only. Verify actual ceiling grid dimensions and ceiling tile reveal prior to ordering. Minimum and Maximum Face of Fitting to Bottom of Ceiling Grid for Each Reducer 6-1/8" (155mm) 4-5/16" 5-5/16" 11-13/16" 5-5/8" 7-3/8" Fitting Distance Straight (110mm) (135mm) (300mm) (143mm) (187mm) Standard Straight Straight Straight Elbow Elbow Max. Face of Fitting 3" (7mm) Distance Above 3" (77mm) 3" (7mm) 3" (7mm) 3" (7mm) 3" (7mm) Bottom of Ceiling Grid Max. Face of Fitting Distance from Bottom 1/8" (3mm) 1-5/8" (42mm) 11/16" (17mm) 6-3/8" (148mm) 1-7/16" (36mm) 5/16" (60mm) of Ceiling Grid below above above below above below Note: Based on 1-11/16" (43mm) tall ceiling grid. Fig. 3 Dimension C - Clearance Above Ceiling Required at Max. Sprinkler Recess Recessed Escutcheon or Concealed/Flush Sprinkler Reducer 5-5/8" (143mm) Elbow 7-3/8" (187mm) Elbow F1 recessed escutcheon NC 5-5/8" (144mm) F2 or FV recessed escutcheon NC 5-3/8" (138mm) FP recessed escutcheon NC 6-1/4" (160mm) CCP conical concealed cover plate NC 6-1/4" (160mm) G4 series concealed sprinklers 5-5/8" (144mm) 7-3/8" (188mm) G5 series concealed sprinklers 5-1/4" (134mm) 7" (179mm) RFC series concealed sprinklers 5-1/4" (134mm) 7" (179mm) XL commercial flush sprinkler with flat escutcheon 4-7/8" (125mm) 6-5/8" (169mm) XL commercial flush sprinkler with conical escutcheon 4-3/8" (112mm) 6-1/8" (157mm) Note: NC - Reducer not compatible with sprinkler adjustment range. Based on 1-11/16" (43mm) tall ceiling grid and flush ceiling tile. Bulletin 213 Reliable Page 3 of 8 May 2021 www.reliablesprinkler.com Materials Figure 4 Number Item Description Material 1 Flexible Hose/Bellow AISI Type 304 Stainless Steel 2 Isolation Ring Nylon 66 3 Gasket EPDM 4 Nut Zinc Plated Carbon Steel 5 Branch Line Nipple (1 ") Zinc Plated Carbon Steel 6 Reducer Zinc Plated Carbon Steel 7 Braid AISI Type 304 Stainless Steel 8 Welded Collar Fitting AISI Type 304 Stainless Steel I - Bar Stock Zinc Plated SGCC Steel - Brackets: Center and Side Zinc Plated SPCC Steel Flexible Hose Number of Bends One Bend Two Bends Figure 5 Three Bends Minimum bend radius 2x 2x Min 1 Min - - \ bend bend radius radius I OR OR Minimum bend radius imum9 radiusL— — — — — —MinimumMinimum bend radius Nradius bbend radius bend radius Do NOT install the RASCOFLEXTM straight. Some flexibility in the form of an allowable bend (or bends) must be provided. Bulletin 213 Reliable Page 4 of 8 May 2021 www.reliablesprinkler.com cLILus Friction Loss Data Nominal Length of Flexible Hose in (mm) Reducer Maximum Sprinkler K-Factor gpm/psi112 (Ipm/bar112) Maximum Number of 90' Bends at 3" (76mm) Bend Radius Equivalent Length of 1" (33.7mm) Sch. 40 Pipe (C=120), ft (m) NPT Threads Type 24 1/2 Straight 5.6(80) 2 10 (3) (610) 3/4 Straight 14.0 (200) 2 13 (4) 31 1/2 Straight 5.6 (80) 3 14(4.3) (790) 3/4 Straight 14.0 (200) 3 16(4.9) 40 1/2 Straight 5.6 (80) 4 21 (6.4) (1015) 3/4 Straight 14.0 (200) 4 23 (7) 48 112 Straight 5.6(80) 4 24(7.3) (1220) 3/4 Straight 14.0 (200) 4 26(7.9) 60 1/2 Straight 5.6(80) 4 25(7.6) (1525) 3/4 Straight 14.0 (200) 4 30(9.1) 72 1/2 Straight 5.6 (80) 5 36 (11) (1830) 3/4 Straight 14.0 (200) 5 33 (10.1) UL Notes: 1. Available data for use with 6.1 " straight reducers. 2. Sprinkler K-Factor: 5.6 (80 metric) for 1/2-inch reducer and 14.0 (200 metric) for 3/4-inch reducer. 3. RASCOFLEX° Sprinkler Connections have been tested and approved by Underwriter's Laboratories, Inc. for use in wet, preaction, and dry sprinkler systems per NFPA 13, 13D, 13R and UL2443. Bulletin 213 Reliable Page 5 of 8 May 2021 www.reliablesprinkler.com FM APPROVED FM Friction Loss Data Nominal Length of Flexible Hose in mm ( ) Reducer Maximum Sprinkler K-Factor 112 (IIpm/bar'12) Maximum Number of 90' Bends at 7" Bend Radius Equivalent Length of 1" (33.7mm) Sch. 40 Pipe p (C=120), ft (m) NPT Threads Type Yp 1/2 Straight 5.6(80) 1 9.7 (2.9) 1/2 90' Elbow 5.6(80) 0 11.5 (3.5) 24 (610) 3/4 Straight 8.0(115) 1 9.9(3) 11.2 (160) 1 9.8 (2.9) 14.0 (200) 1 9.6 (2.9) 3/4 90' Elbow 8.0(115) 0 10.2 (3.1) 11.2 (160) 0 10 (3) 14.0 (200) 0 9.8 (2.9) 1/2 Straight 5.6 (80) 2 12.4 (3.8) 1/2 90' Elbow 5.6(80) 2 15.8 (4.8) 31 (790) 3/4 Straight 8.0(115) 2 13.7(4.1) 11.2 (160) 2 12.9 (3.9) 14.0 (200) 2 12.2 (3.7) 3/4 90' Elbow 8.0(115) 2 14.5 (4.4) 11.2 (160) 2 13.7 (4.1) 14.0 (200) 2 13(3.9) 1/2 Straight 5.6 (80) 2 15.9 (4.8) 1/2 90' Elbow 5.6(80) 2 21.6 (6.6) 40 (1015) 3/4 Straight 8.0(115) 2 18.5 (5.6) 11.2 (160) 2 17.4 (5.3) 14.0 (200) 2 16.3 (4.9) 3/4 90' Elbow 8.0(115) 2 20 (6) 11.2 (160) 2 18.9 (5.7) 14.0 (200) 2 20 (6) 1/2 Straight 5.6(80) 3 19.0 (5.8) 1/2 90' Elbow 5.6(80) 3 25.9 (7.9) 48 (1220) 3/4 Straight 8.0(115) 3 22.7 (6.9) 11.2 (160) 3 21.5 (6.5) 14.0 (200) 3 20.5 (6.2) 3/4 90' Elbow 8.0(115) 3 24.8 (7.5) 11.2 (160) 3 23.6 (7.2) 14.0 (200) 3 22.6 (6.8) Bulletin 213 Reliable Page 6 of 8 May 2021 www.reliablesprinkler.com FM Friction Loss Data (cont.) Nominal Length of Flexible Hose in mm ( ) Reducer Maximum Sprinkler K-Factor 112 (Ipm/bar"2) Maximum Number of 90' Bends at 7" Bend Radius Equivalent Length of 1" (33.7mm) Sch. 40 Pipe p (C=120), ft (m) NPT Threads Type Yp 1/2 Straight 5.6(80) 4 23.7 (7.2) 1/2 90' Elbow 5.6(80) 4 33.1 (10) 60 (1525) 3/4 Straight 8.0(115) 4 29.1 (8.8) 11.2 (160) 4 28(8.5) 14.0 (200) 4 27(8.2) 3/4 90' Elbow 8.0(115) 4 32.2 (9.8) 11.2 (160) 4 31.1 (9.5) 14.0 (200) 4 30(9.1) 112 Straight 5.6(80) 4 28.4 (8.6) 1/2 90' Elbow 5.6(80) 4 40.4 (12.3) 72 (1830) 3/4 Straight 8.0(115) 4 35.5 (10.8) 11.2 (160) 4 34.3 (10.4) 14.0 (200) 4 33.2 (10.1) 3/4 90' Elbow 8.0(115) 4 39.5 (12) 11.2 (160) 4 38.3 (11.6) 14.0 (200) 4 37.2 (11.3) FM Notes: 1. RASCOFLEX° Sprinkler Connections have been tested and approved by FM Approvals for use in wet, preaction, and dry sprinkler systems per FM data sheets 2-0, 2-5, and 2-8 per FM1637. 2. Maximum sprinkler K-Factor: 5.6 (80 metric) for 1/2-inch reducer and 14.0 (200 metric) for 3/4-inch reducer. 3. Differences in equivalent lengths are due to varying test methods, per FM 1637 standards. 4. Above data of friction loss for use with 6.1 " straight reducers. Bulletin 213 Reliable Page 7 of 8 May 2021 www.reliablesprinkler.com Accessories List 5-5/8" (143mm) 7-3/8" (187mm) 4traigh ( Elbow Reducer- Elbow Reducer- Reducer Straight Reducer Short Long 1 /2": 7 M 99003306 1 /2": 7M99003303 1 /2": 7M99003302 3/4": 7M99003325 3/4": 7M99003305 3/4": 7M99003304 Replacement 5-5/16" (135mm) _ 6-1/8" (155mm) 11-13/16" (300mm) Straight Reducer = Standard Straight Straight Reducer 4 Reducer 1 /2": 7M99003307 1 /2": 7M99003309 3/4":7M99003326 1/2":7M99003308 3/4":7M99003328 3/4": 7M99003327 Hat Channel End Hat Channel End Metal Stud End Bracket- Short Bracket- Long Bracket -Short 1-1/2" 3" (76mm) 3-3/4" (95mm) (38mm) 7M99003310 7M99003311 7M99003312 Metal Stud End Bracket- Long Long Long fl T-Bar End Bracket- Short 2-5/8" (68mm) T-Bar End Bracket- Long 4-1/8" (105mm) {4 -! 7M99003314 71V99003316 7M99003313 Wood Beam Stud End Bracket 7M99003317 + Replacement Center Bracket 3" (76 mm) Bend Radius Indicator 7M99003321 if 7M99004179 1" Replacement NPT Inlet Adapter #2 Square Drive Bit 7M99004539 Replacement Gasket 7M99004319 7M99003322 48" (1220mm) Bracket Assembly 7M99003301 Bulletin 213 Reliably Page 8 of 8 May 2021 www.reliablesprinkler.com Bulletin 014 August 2021 limablLs Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Con- tent Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FIR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprinkler. 1. Underwriters Laboratories Inc. and Certified for Cana- da (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS SchadenverhOtung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Lab- oratories of Canada Certified for Health Effects to NSF/ ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) 7. WaterMark certified. Certificate Number 23347. (WM) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Model F1 FR Series Quick Response Glass Bulb Sprinklers Upright Pendent Conventional W J Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1 FIR series sprinklers are quick -response automatic sprinklers with a glass bulb thermal element. Model F1 FIR series sprinklers are Standard Spray sprinklers, with the exception of the Model F1 FR56 Conventional sprinkler which is XLH Recessed an Old-style/Conventional sprinkler. Pendent FP The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FIR Series sprinklers to apply water to a fire faster than standard -response sprinklers of the same tem- perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. c D 0 D cQ U) N) 0 N2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. Model F1 FIR Series sprinklers provide a wide range of options where quick -response, glass bulb sprinklers are used: • Pendent, recessed pendent, upright, horizontal side - wall, and vertical sidewall deflectors • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) • Flush, recessed, and concealed installations See the Design and Installation Information table in this Bul- letin for information on the approvals and availability of specific Model F1 FIR series sprinkler configurations. Model F1 FIR Recessed Pendent and Recessed Horizontal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Recessed Es- cutcheon Data table in this Bulletin for listing and approval infor- mation with each specific Model F1 FIR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cover plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.Omm) of cover plate adjustment. See the Design and Installation Infor- mation and Listed and Approved Temperature Ratings tables in this Bulletin for further information on approved cover plate options. Application Model F1 FIR Series sprinklers are intended for use in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Having Juris- diction. Care must be exercised that the k-factor, tempera- ture rating, deflector style, and sprinkler type are in accor- dance with the requirements of the applicable design and installation standards. In addition, Model F1 FIR Series sprin- klers must be used in accordance with their listings and ap- provals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or protec- tive caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Re- move the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protec- tor before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1 FIR Series sprinklers must be installed with the Reli- able sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1 FIR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the specific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1 FIR Series Recessed sprinkler. The use of any other recessed escutcheon will void all approvals and negate all warranties. Concealed Sprinklers Model F1 FIR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers have a facto- ry -installed Model CCP cup. A protective cap is installed at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread- off cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1 FIR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1 FIR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model W4 wrench is used to engage the sprinkler wrenching sur- faces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent dam- age to the sprinkler. Do not wrench any other part of the sprinkler/ cup assembly. Installation is completed by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/ cup assembly other than the Reliable Model CCP with Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not spe- cifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick -response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1 FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 W4 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1 FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 W4 RA1410 cULus, ULH F1 FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 (F1 FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 cULus, FM, Pendent 2.25 57 W2 RA1414 LPCB, VdS, EC, 1,2,3,4 WM cULus, FM, Recessed Pendent 2.25 57 W4 RA1414 LPCB, VdS, EC, 1,2,3,4 WM F1 FR56 5.6 80 112 15 Concealed Pendent 2.25 57 W4 RA1414 cULus VdS,EC, WM 5,6 cULus, FM, Upright 2.25 57 W2 RA1425 LPCB, VdS, EC, 1,2,3,4 WM "Conventional (Pendent or Upright)" 2.25 57 W2 RA1475 LPCB, VdS, EC, WM 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 1 57 W4 RA14151 cULus, ULH F1 FR56LL 5.6 80 112 15 Concealed Pendent 2.25 1 57 W4 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 F1 FR56 5.6 80 112 15 Recessed Horizontal Sidewall 2.63 67 W4 RA1435 cULus, FM 8 F1 FR56 5.6 80 1/2 15 Vertical Sidewall (Pen- dent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 (') cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (1) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (1) VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 1550F (68°C) temperature rated sprinklers only. VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (1) Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (') cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (1) cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (1) The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100T (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150T (65°C) Max. Ambient Temp. High Temp. Classification 225T (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Ratin 175°F (79°C) Temp. Rating 200oF (93-C) Temp. Rating 286T (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1 FR28 Recessed Pendent cULus Upright cULus Pendent VdS F1 FR40 Recessed Pendent VdS Pendent cULus F1 FR42 Recessed Pendent cULus Upright cULus FlFR42LL Pendent Recessed Pendent I cULus, ULH I cULus, ULH Pendent cULus F1 FRXLH Recessed Pendent cULus Upright cULus Pendent cULus, FM, LPCB, VdS, EC, WM Recessed Pendent cULus, FM, LPCB, VdS, EC, WM F1 FR56 Concealed Pendent cULus, WM cULus VdS,EC, WM cULus, WM Upright cULus, FM, LPCB, VdS, EC, WM "Conventional Pendent or Upright)" LPCB, VdS, EC, WM Pendent cULus, ULH F1FR56LL Recessed Pendent cULus, ULH Concealed Pendent EJL���cULus, ULH Horizontal Sidewall cULus, FM F1 FR56 Recessed Horizontal Sidewall cULus, FM rF1 FR56 Vertical Sidewall (Pen- dent or Upri ht cULus, FM, LPCB * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- termediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model F1 Model F2 Model FP Model Deflector/ (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1 FR28 Recessed Pendent cULus cULus cULus RA1411 F1 FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 FlFR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 FlFR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC, WM RA1414 EC, WM VdS, EC, WM FlFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 9 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS --�\\ F7 ESCUTCHEONr//1� 3/4'[19mm] e1 ADJUSTMENT F2 ESCUTCHEON 112'T 12.7mm] ADJUSTMENT 2 114" HOLE DIA. [57.2mmJ 1 15116" DIA [49.2mmJ l F S i i -1 II II L J� 2 27132" DIA. [72.2mmJ 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = i'[25.4mm] AT MINIMUM RECESS = 318'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'[19mm] AT MINIMUM RECESS = 318'T9.5mml F1 ESCUTCHEON AT MAXIMUM RECESS = 7/8'T22.2mm] [3.2mmJ AT MINIMUM RECESS = 1-5/8'[41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'[28.6mm] AT MINIMUM RECESS = 1-5/8'T41.3mm] Fig. 1 Model F1 FR56, F1 FR561-L, F1 FR42, F1 FR40, F1 FR421-L, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1 " X 1/2"' REDUCER -----I----- 2 5/8" DIA. [66.7mm] HOLE IN CEILING 1 I 2 5/16" DIA. [58.7mm] CUP L J CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION - AT MAXIMUM RECESS = 1-1/2"T38mm] AT MINIMUM RECESS = 1 'T25.4mm] AT MAXIMUM RECESS = 9/16'T14.3mm] %2'T 12.7mm] AT MINIMUM RECESS = 1 'T25.4mm] ADJUSTMENT 3 1/4" DIA. [82.6mm] Fig. 2 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = I 'T25.4mm] AT MINIMUM RECESS = 318'T9.5mm] E2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'T 19mm] AT MINIMUM RECESS = 3/8'T9.5mm] 2 114" HOLE DIA. [57.2mm] 1" X 112" REDUCER i i um I 1 15116" DIA. / uw [49.2mm] of um � um i TURN COLLAR UNTILu TIGHT AGAINST SPRINKLER WRENCH BOSS. 118" [3.2mm] F1 ESCUTCHEON AT MAXIMUM RE ESS 1 3 8" 34 9 C = - / [ . mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] 2 27/32" DIA. [72.2mm] F1 ESCUTCHEON 3/4'T 19mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T 12.7mm] ADJUSTMENT 1 (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR oiarcoM RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon I" x 112" REDUCING TEE OR ELBOW 2 5116" DIA — CUP CEILING 2 518 " DIA. HOLE IN CEILING 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION I 112 " MAX. COVER ADJUSTMENT j COVER PLATE / ASSEMBL Y 3 5116 " DIA SPRINKLER 15/16" CONCEALED. 1 /2" ADJUSTMENT 017FG01A Fig. 4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate Al I' x TEE 112" REDUCING OR ELBOW _ 2 5116" CEILING 5116 " MAX. --I COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER - 2 518" DIA. HOLE IN CEILING 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING """' DIMENSION CONCEALED, 5/16" ADJUSTMENT 017FG02A ncealea renaent sprinKler wltn low inch (8.Omm) adjustment - Model CCP cover plate Maintenance The Model F1 FIR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plateM Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated (4)(5)(6) White Painted Special Application Finishes S rinkler Escutcheon Cover plateM Electroless Nickel PTFE'> Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Paint(2)(6) Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (') Other finishes and colors are available on special order. Consult the fac- tory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. (') cULus listed Corrosion Resistant 514" Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT] [ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135'F (57°C)][155'F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.Omm) adjustment] 9. Cover plate Temperature Rating: [135'F (57'C) for use with Ordinary Temperature sprinklers][165°F (74'C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1 FIR Series Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper Reliabld (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 08/21 P/N 9999970300