FIR2021-0153+Fire_Alarm_Plan+12.27.2021_11.44.18_AM+259246621 72%GTE AVE W SU TE F EDMONDS, WA 98026 FIRE ALARM DESIGN WIRE LEGEND SCL CIRCUIT: 2 CONDUCTOR 18 AWG A FPLP FIRE ALARM CALBLE B VISUAL NAC CIRCUIT: 2 CONDUCTOR 14 AWG FPLP FIRE ALARM CALBLE SEQUENCE OF OP ER AT ON OUTPUT SOUND ALL DEVICES DISPATCH "RE DEPARTMENT SOUND SIGNAL AT FACP CALL CENTRAL STATION AND PREMISE CALL SERNCE TECH RECALL ELEVATOR SOUND SUPERVISORY SIGNAL AT FACP WATER FLOW VALVE TAMPER SMOKE DETECTOR INPUT MANS PULL STATION HEAT DETECTOR GROUND FAULT GENERAL TROUBLE DUCT SMOKE DETECTOR EQUIPMENT LEGEND SYMBOL QTY PART # DESCRIPTION BACK BOX Ps EXISTING PSE-6 NAC PANEL INCLUDED 9 SWL CEILING STROBE 3 PC2WL CEILING HORN STROBE FIRE ALARM DESIGN NOTES: 1. SYSTEM DESIGN BASED ON INTERNATIONAL FIRE CODE 2018, NFPA 72 2018, NFPA 70 (NEC— 2020 AND/OR LOCAL AUTHORITY HAVING JURISDICTION CODES AND/OR ADDENDUM CRITERIA. 2. WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER. 3. PULL STATIONS TO BE MOUNTED: 3.1. 42" — 48" AFF 3.2. WITHIN 5' OF THE DOOR. 4. FIRE ALARM CONTROL PANEL TO BE ON UN—SWTCHED, DEDICATED 120VAC CIRCUIT WITH CIRCUIT BREAKER LOCK ON. 5. WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT UNLESS IN OCCUPANCY WHERE CONDUIT IS REQUIRED THROUGHOUT. SMOKE DETECTORS TO BE INSTALLED: 5.1. MORE THAN 36" FROM ANY HVAC DIFFUSER 5.2. NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTIN 5.3. AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 6. ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). SITE SPECIFIC FIRE ALARM NOTES: 1. JOB SITE SAFETY INSPECTION TO BE PERFORMED AT THE BEGINNING OF EACH PROJECT AND AT THE BEGINNING OF EACH WORK DAY IF MORE THAN TWO DAYS HAVE PASSED SINCE LAST DAY ON SITE. 2. FIRE ALARM CONTROL PANEL TO BE PUT IN TEST AT THE BEGINNING OF EACH WORK DAY, REGARDLESS OF SCOPE OF WORK FOR THAT DAY. 6'-0" FACP FIRE ALARM CONTROL PANEL TYPICAL MOUNTING HEIGHTS CO OR SMOKE DET J L THERMAL DETECTOR I � MIN. 6 TO CLG. CEILING HORN/STROBE) WALL HORN/STROBE 6'-0" PS NAC POWER SUPPLY FAA 4'-8" El 1 6'8" N 10'0" 4'0" FRONT ACCESS 4'6" SIDE ACCESS Approved by Fire 01/05/2022 AFM 1</-F�tterer —TTT7 T T TTTTTT 7 � � r � rTT� • • Y •' • SHEET INDEX SHEET NUMBER SHEET TITLE FA-1 .0 COVER PAGE FA-2.0 FIRST FLOOR FIRE ALARM PLAN FA-3.0 RISER AND DETAILS CODE ANALYSIS BUILDING OCCUPANCY NUMBER OF STORIES 1 SYSTEM TYPE CONVENTIONAL CODE EDITIONS IBC, IFC, IMC 2012 NFPA 72 2013 NFPA 70 NEC 2014 AUDIBLE/VISUAL NOTIFICATION TEMPORAL / PUBLIC MODE Kristopher Canner, SET Fire Alarm Systems Level IV #120491 exp.09/01/2022 CID 00 r-4_ F CID CO M 0� J Q � U O o UW a E .�..i U O X Q UU Q w a p� LJ L� LL Q CO 0 ^ I--1 1n o U W r� Q N O O � U J •P 0 �-1 3 Uz o Z o1-- o Ir L3 00 ro LLJ ���• -� •��• o o •��• a o W U • 0 0 • It�k IZ .... Q 3:: o cc 4- I I 0 N 0 N Lil �/ 41 w Cl- c� U N o Q rn Co Cn 1i Q z L'i Z CD Zo J Q N =o Q O CC C Z cry ^ O J Z O R) U w N LEI m Z ~ T Q m � w cry z W LJ C-0 Q en Z Z Q Z � W wCn N a Cn a RECEIVED Dec 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2021-0153 APPROVALS REQUIRED 1 1 REVI DATE I DESCRIPTION 1 PROJECT NUMBER 25ASO462 SHEET TITLE:COVER PAGE DESIGNER DATE FIRE & RM lKSaEM 12/02/2021 SHEET FA-1.0 15CD- SEATTLE SKIN & LASER FA PLAN N SCALE:1/8" = 1'-0� s• t x 15CD 30CD 15CD 15CD 15CL x 15CD 15CD 15CD 15CD 15CD 15CD 15CD B PS I NAC 1 - I �V-- I� /4- MA N SEATTLE SKIN & LASER RISER DIAGRAM N SCALE: NO SCALE 0 s• t 2- Kristopher Canner, SET Fire Alarm Systems Level IV #120491 exp.09/01/2022 O Lo M r Ln I pO I� 0 J Q OCV UW � fain x U0 O � Q U1 W O ^ 1 W W J UwQ 0 Z O r) r7 � I ro •.• • U W ���• ~O IX o •��• EL `" •��• W .... IX a_ W U a00 J � O r� Q 2 Q ZD J 0 Y 0 O ~ r7 00 O en ry O E O U 4J Of L. O U N O U 3 3 Z O L.� O U N O U Q o co co M I 0 0 C14 LLjry z z w Q z U cc) N o Q (7) Cn Cn W MeO Q N Q z Zo J cry =o �_ O Z ^ O J U Z K, C = LiJ r` o U O N W r` Cl- Z N Q m CD Z ~ T Of � Q m LLJ � �, Z 'i W en � C.� Q Z Z Q Z � W F— d Uf Cl- RECEIVED Dec 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT F I R2021-0153 APPROVALS REQUIRED 1 1 REVI DATE I DESCRIPTION 1 PROJECT NUMBER 25ASO462 SHEET FA PLAN & RISER DESIGNER DATE FIRE & RM DBGNER 12/02/2021 SHEET FA-2.0