Loading...
APPROVED BLD Plans+7.21.2020_12.22.07_PMGENERAL NOTES (THE FOLLOWING APPLY UNLESS NOTED OTHERWISE ON THE PLANS) I IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BECOME FULLY AWARE OF ANY AND ALL CONDITIONS RELATED TO THE SITE AND EXISTING CONDITIONS THAT MAY EFFECT THE COST OR SCHEDULING OF CONSTRUCTION ACTIVITIES PR10R TO SUBMITTING BID. 2 ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE FOLLOWING APPLICABLE CODES USED IN THE DESIGN: 201 5 INTERNATIONAL RESIDENTIAL CODE 201 5 WASHINGTON STATE ENERGY CODE 201 2 SRC M 1507 WHOLE HOUSE VENTILATION SEATTLE STORMWATER, GRADING AND DRAINAGE CONTROL CODE. 3 CONTRACTOR: SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND 4 DO NOT SCALE DRAWINGS OR DETAILS - USE GIVEN DIMENSIONS. CHECK DETAILS FOR LOCATION OF ALL ITEMS NOT DIMENSIONED ON PLANS. DOOR AND CASED OPENINGS WITHOUT DIMENSIONS ARE TO BE SIX (6) INCHES FROM FACE OF ADJACENT WALL OR CENTERED BETWEEN WALLS UNLESS NOTED OTHERWISE. 5 INSTALL DUST BARRIERS AND OTHER PROTECTION AS REQUIRED TO PROTECT INSTALLED FINISHES AND FACILITIES. 6 PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE INSTALLATION OF THEIR WORK. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEERS) OR OTHER SUPPLEMENTARY DRAWINGS SHALL BE BROUGHT TO THE OWNERS ATTENTION IN WRJTING. 7 CONTRACTOR: SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 8 CONTRACTOR: SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. 9 DRAWINGS: INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. I O WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT/DESIGNER. I I ALL WOOD PLATES: IN DIRT=CT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE. PROVIDE 2 LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTR;=ATED LEDGERS, BLOCKING, ETC., AND CONCRETE OR MASONRY. 12 THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS. VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS NOTED AS EXPOSED CONSTRUCTION ON THE DRAWINGS. OFFSET STUDS WHERE REQUIR;=D, SO THAT FINISHED WALL SURFACE WILL BE FLUSH. 13 PRESSURE TREATED LUMBER: ALL FASTENERS AND CONNECTORS THAT ARE IN CONTACT WITH PRi=SSURE TRi=ATED LUMBER SHALL BE HOT DIPPED GALVANIZED WITH A MINIMUM COATING OF G90 (.90oz/sf) PER ASTM AI 23 AND/OR ASTM AI 53. 304 OR 316 14 STAINLESS STEEL MAY BE SUBSTITUTED IN LIEU OF GALVANIZED PRODUCTS. NO STAINLESS STEEL PRODUCTS SHALL COME IN CONTACT WITH GALVANIZED PRODUCTS. 15 CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 16 ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR EXPOSED WEATHER SHALL BE PRESSURE TR;=ATED WITH AN APPROVED PRESERVATIVE UNLESS DECAY RESISTANT HEARTWOOD OF CEDAR OR REDWOOD IS USED. FASTENERS FOR PRESSURE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL SILICON BRONZE OR COPPER. 17 PROVIDE GALVANIC INSULATION BETWEEN DISSIMILAR METALS. 18 STRUCTURAL ELECTRICAL, MECHANICAL AND ENERGY NOTES ARE LOCATED WITHIN THIS SET OF DRAWINGS. 19 THE CONTRACTOR IS TO VERJFY THE LOCATION OF ALL UTILITIES AND SERVICES TO THE SITE PRIOR TO BEGINNING ANY SITE IMPROVEMENTS. 20 NO MATERIALS FROM THE WORK ARE TO BE STOCK PILED ON THE PUBLIC RIGHT-OF-WAYS. ALL RUBBISH AND DEBRIS IS TO BE REMOVED FROM THE SITE. 2 I ADJACENT PROPERTIES, STREETS AND WALKS ARE TO BE PROJECTED FROM DAMAGE AT ALL TIMES. 22 CONSTRUCTION BARRICADES: PROVIDE CONSTRUCTION BARRICADE AS REQUIRED TO KEEP PUBLIC AND EMPLOYEES SAFE, FOLLOWING ALL APPLICABLE FEDERAL STATE AND CITY CODES AND REGULATIONS. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES DURING THE COURSE OF THE PROJECT. 23 APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, AGENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. SAID PLANS ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. 24 CONTRACT DOCUMENTS WHICH DESCRIBE EXISTING CONSTRUCTION HAVE BEEN BASED ON FIELD INSPECTION AND OWNER SUPPLIED DOCUMENTS, BUT NOT BASED ON EXTENSIVE FIELD MEASUREMENTS, OPENING OF CONCEALED CONDITIONS OR EXCAVATED OF BURIED ITEMS. EXISTING CONDITIONS DO NOT ACCURATELY FOLLOW THE ORIGINAL CONSTRUCTION DRAWINGS. THESE DRAWINGS ARE INTENDED AS A GUIDE TO THE CONTRACTOR WHO SHALL VERIFY DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH WORK. 25 CONTRACTOR TO MAINTAIN IN FORCE AT ALL TIMES, INSURANCE AS REQUIRED BY ARTICLE II OF THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201 . CERTIFICATES EVIDENCING SAID INSURANCE SHALL BE PROVIDED TO THE OWNER, PRIOR TO COMMENCEMENT OF ANY WORK. 26 THE CONTRACTOR ANDJOR THE SUBCONTRACTORS SHALL APPLY FOR, OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND FEES EXCEPT FOR THE BUILDING PERMIT. 27 PLAN DIMENSIONS ARE TO FACE OF EXTERIOR STUD; INTERIOR WALLS ARE DIMENSIONED TO THE FACE OF INTERIOR STUD UNLESS NOTED OTHERWISE CONTRACTOR IS TO REFER TO STRUCTURAL PLANS FOR FRAMING DIMENSIONS AND WILL ACCOUNT FOR THE REQUIRED CLEARANCES � TOLERANCES. 28 VERIFY LOCATION OF ALL EXISTING UTILITIES. CAP, MARK #PROTECT AS NECESSARY TO COMPLY WITH THE WORK. 29 ALL ANGLES ARE 90 OR 45 DEGRi=ES OR MATCH EXISTING, UNLESS OTHERWISE NOTED. 30 REPETITIVE FEATUR;=S MAY BE DRAWN OR NOTED ONLY ONCE, BUT SHALL BE PROVIDED AS IF DRAWN IN FULL. 3 I PLACE ALL MECHANICAL OR ELECTRICAL WALL AND ROOF PENETRATIONS AT LOCATIONS AS INDICATED ON DRAWINGS. Ri=VIEW WITH ARCHITECT ALL LOCATIONS PRIOR TO INSTALLATION. 32 ALL FLASHING AND SHEET METAL SHALL COMPLY WITH S.M.A.C.N.A. STANDARDS AND ALL APPLICABLE CCDES. 33 REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL NOTES AND SYMBOLS. LAY OUT FRAMING TO ACCEPT ALL LIGHT FIXTURES, GRILLS AND DUCTS. PROVIDE FURRING AS REQUIRED TO CONCEAL MECHANICAL AND ELECTRICAL WORK IN FINISHED AREAS. CONSULT ARCHITECT BEFORE COVERING ALL MECHANICAL AND ELECTRICAL WORK. 34 CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND ENGINEER FOR APPROVAL PRIOR TO FABRJCATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 35 REFERENCING OF GENERAL AND KEY NOTES IS FOR CONTRACTOR CONVENIENCE ONLY AND DOES NOT LIMIT OR RESTRICT THEIR APPLICATION. 36 COORDINATION: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS. 37 THESE NOTES ARE IN ABBREVIATE FORM. THE INTENT IS TO FURTHER DEFINE THOSE AREAS OF WORK NO CLEARLY DELINEATED ON THE DRAWINGS. THE QUALITY OF WORKMANSHIP THROUGHOUT SHALL BE FIRST CLASS AND ALL MATERIALS SHALL MEET OR EXCEED THE NORMAL INDUSTRY STANDARDS APPLICABLE IN EACH CASE. 38 BUILDING ENCLOSUR;=: RCW 64.55.010 -THE BUILDING ENCLOSURE INCLUDES, BUT IS NOT LIMITED TO, PORTIONS OF ROOFS, WALLS, BALCONY SUPPORT COLUMNS, DECKS, WINDOWS, DOORS, VENTS, AND OTHER PENETRATIONSTHROUGH EXTERIOR WALLS WHICH WATERPROOF, WEATHERPROOF, OR OTHERWISE PROTECT THE BUILDING OR ITS COMPONENTS FROM WATER OR MOISTURE INTRUSION. 39 ALL SIDING METHODS MUST HAVE A WEATHER RESISTIVE BARRIER THAT MEETS THE REQUIR;=MENTS OF 201 5 IRC R703.2. GENERAL WEATHER PROTECTION FOR THE ENTIRE PROJECT MUST MEET THE REQUIRi=MENTS OF IRC 201 5 R903. 40 ALL CEILING HEIGHTS MUST MEET THE REQUIREMENTS OF 201 5 IRC R305. I PER 401 .4 (SITE -SPECIFIC GEOTECHNICAL REPORTS SHALL GOVERN) 2 EXCAVATION CUTS ARE TO BE NO STEEPER THAN I : I , HORIZONTAL TO VERTICAL. [H I :V I ] U.N.O. ADDITION MIN. I' HORIZONTAL DISTANCE FOR WORKING CLEARANCE. 3 3. FILL TO BE FREE OF DEBRIS, ORGANIC CONTAMINANTS AND ROCK FRAGMENTS LARGER THAN 6 INCHES. USE FREE -DRAINING SAND OR SAND AND GRAVEL CONDITIONED TO APPROPRIATE MOISTURE CONTENT FOR ADEQUATE COMPACTION. FILL SHALL CONTAIN NO MORE THAN 5% FINES RELATIVE TO THE FRACTION PASSING THE 3/4" SIEVE. FOR HOUSE, SLAB OR PAVEMENT AREAS, COMPACTION OF FILL TO BE AT LEAST 95% OF THE MAXIMUM DRY DENSITY (MDD) PER ASTM D-1557 TESTING PROCEDURES. UTILITY TRENCH BACKFILL IN SETTLEMENT -SENSITIVE AREAS TO BE COMPACTED AT LEAST 90% OF THE MDD, EXCEPT FORTHETOP 2 FEET WHICH SHOULD BE COMPACTED TO 95% OF THE MDD. 4 4. STRUCTURAL FILL TO BE PLACED IN LOOSE LAYERS OF NOT MORE THAN 8" LAYERS FOR HEAVY EQUIPMENT, OR 4" FOR LIGHTWEIGHT COMPACTION EQUIPMENT. FILL SHOULD BE CONDITIONED TO THE PROPER MOISTURE CONTENT FOR COMPACTION. COMPACT EACH LIFT BEFORE PLACING SUBSEQUENT LAYERS 5 5. FOR FOOTINGS SUPPORTED ON STRUCTURAL FILL, THE 7.ONE OF STRUCTURAL FILL SHOULD F�(TEND LATERALLY OUT FROM THE LOOTING EDGES A DISTANCE AT LEAST EQUAL TO THE THICKNESS OF THE STRUCTURAL FILL. STRUCTURAL FILL PLACED BENEATH FOOTING SHOULD BE COMPACTED TO AT LEAST 95% OF THE MDD IN ACCORDANCE WITH ASTM D-I 557. 6 6. ALL EXTERIOR AND INTERIOR FOOTINGS TO BE AT LEAST 18" AND 12" RESPECTIVELY BELOW THE LOWEST FINISHED ADJACENT GRADE. 7 7. CRAWL SPACE PER R408. I CONSTRUCTION, PROJECTIONS, OPENINGS AND PENETRATIONS OF EXTERIOR WALLS OF DWELLINGS AND ACCES50RY BUILDINGS SHALL COMPLY WITH TABLE 302. I (I ); OR DWELLINGS EQUIPPED THROUGHOUT WITH AND AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION P2904 SHALL COMPLY WITH TABLE 3022(2) EXTERIOR WALL ELEMENT MINIMUM FIRE -RESISTANCE RATING MINIMUM FIRE SEPARATION DISTANCE WALLS FIRE -RESISTANCE RATED I HRTESTED IN ACOORDANCE WITH ASTM E 119 OR UL 263 WITH EXPOSURE FROM BOTH SIDES < 5 FT NOT FIRE- RESISTANCE RATED 0 HOURS S 5 FT NOT ALLOWED N/A < 2 FT PROJECTIONS FIRE -RESISTANCE RATED I HOUR ON THE UNDERSIDE <_ 2 FT TO <5 FT NOT FIRE- 0 HOURS <_ 5 FT RESISTANCE RATED NOT ALLOWED N/A < 3 FT OPENINGS IN WALLS 25% MAXIMUM OF WALL AREA 0 HOURS 3 FT UNLIMITED 0 HOURS 5 FT COMPLY WITH SECTION R302.4 < 3 FT PENETRATIONS ALL NON REQUIRED 3 FT R302.5 OPENING PROTECTION I OPENINGS AND PENETRATIONS THROUGH THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE IN ACCORDANCE WITH SECTIONS R302.5. I THROUGH R302.5.3. 2 OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN I 3/8 INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 13/ 8 INCHES (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. 3 DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4 PENETRATIONS THROUGH THE SEPARATION REQUIRED IN SECTION R302.6 SHALL BE PROTECTED AS REQUIRED BY SECTION R302. I i ,ITEM 4. R302. I I SOLID FIREBLOCKING IN COMBUSTIBLE CONSTRUCTION, SOLID FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. SOLID FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: I IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: 2 VERTICALLY AT THE CEILING AND FLOOR LEVELS. 3 HORIZONTALLY AT INTERVALS NOT EXCEEDING I 0 FEET (3048 MM). 4 AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 5 IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.7. 6 AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM E 136 REQUIREMENTS. 7 FOR THE SOLID FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION RI 003. 19. 8 SOLID FIREBLOCKING OF CORNICES OF ATWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING UNIT SEPARATION R302 . � DWELLING /GARAGE FIRE SEPARATION I THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302.6. OPENINGS IN GARAGE WALLS SHALL COMPLY WITH SECTION R302.5. THIS PROVISION DOES NOT APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL. SEPARATION a. FROM THE RESIDENCE AND ATTIC b. FROM ALL HABITABLE ROOMS ABOVE THE GARAGE c. STRUCTURE{S) SUPPORTING FLOOR/CEILING ASSEMBLIES USED FOR SEPARATION REQUIRED BY THIS SECTION d. GARAGES LOCATED LESS THAN 3 FEET FROM A DWELLING UNIT ON THE SAME LOT. MATERIAL A. NOT LESS THAN !/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE B. NOT LESS THAN 5i8-INCH TYPE X GYPSUM BOARD OR EQUIVALENT C. NOT LESS THAN I/2-INCH GYPSUM BOARD OR EQUIVALENT D. NOT LESS THAN I/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE INTERIOR SIDE OF EXTERIOR WALLS THAT ARE WITHIN THIS AREA R302.7 UNDER -STAIR PROTECTION I ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER -STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH I/2-INCH (I 2.7 MM) GYPSUM BOARD. U.N.O R303 LI Gt1T, VENTI LATI ON � t1 EATI NG ALL HABITABLE ROOMS SHALL HAVE AN AGGREGATE GLAZING AREA OF NOT LESS THAN 8 PERCENT OF THE FLOOR AREA OF SUCH ROOMS. NATURAL VENTILATION SHALL BE THROUGH WINDOWS, DOORS, LOUVERS OR OTHER APPROVED OPENINGS TO THE OUTDOOR AIR. SUCH OPENINGS SHALL BE PROVIDED WITH READY ACCESS OR SHALL OTHERWISE BE READILY CONTROLLABLE BY THE BUILDING OCCUPANTS. THE MINIMUM OPEN -ABLE AREA TO THE OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR AREA BEING VENTILATED. EXCEPTIONS: a. THE GLA7_ED AREAS NEED NOT BE OPENABLE WHERE THE OPENING IS NOT REQUIRED BY SECTION R310 AND AN APPROVED MECHANICAL VENTILATION SYSTEM CAPABLE OF PRODUCING 0.35 AIR CHANGE PER HOUR IN THE ROOM IS INSTALLED OR A WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM IS INSTALLED CAPABLE OF SUPPLYING OUTDOOR VENTILATION AIR OF 15 CUBIC FEET PER MINUTE (CFM) (78 US) PER OCCUPANT COMPUTED ON THE BASIS OF TWO OCCUPANTS FOR THE FIRST BEDROOM AND ONE OCCUPANT FOR EACH ADDITIONAL BEDROOM. b. THE GLAZED AREAS NEED NOT BE INSTALLED IN ROOMS WHERE EXCEPTION I ABOVE IS SATISFIED AND ARTIFICIAL LIGHT IS PROVIDED CAPABLE OF PRODUCING AN AVERAGE ILLUMINATION OF G FOOTCANDLES (65 LUX) OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES (762 MM) ABOVE THE FLOOR LEVEL. c. USE OF SUNROOM ADDITIONS AND PATIO COVERS, AS DEFINED IN SECTION R202, SHALL BE PERMITTED FOR NATURAL VENTILATION IF IN EXCESS OF 40 PERCENT OF THE EXTERIOR SUNROOM WALLS ARE OPEN, OR ARE ENCLOSED ONLY BY INSECT SCREENING. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LESS THAN 3 SQUARE FEET (0.3 M2), ONE-HALF OF WHICH MUST BE OPEN -ABLE. EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CUBIC FEET PER MINUTE (24 L/S) FOR INTERMITTENT VENTILATION OR 20 CUBIC FEET PER MINUTE (10 L/S) FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. ALL INTERIOR AND EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH A MEANS TO ILLUMINATE THE STAIRS, INCLUDING THE LANDINGS AND TREADS. INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH LANDING OF THE STAIRWAY. REQUIRED GLAZED OPENINGS SHALL OPEN DIRECTLY ONTO A STREET OR PUBLIC ALLEY, OR A YARD OR COURT LOCATED ON THE SAME LOT AS THE BUILDING. EXCEPTIONS: a. REQUIRED GLAZED OPENINGS MAY FACE INTO A ROOFED PORCH WHERE THE PORCH ABUTS A STREET, YARD OR COURT AND THE LONGER SIDE OF THE PORCH IS AT LEAST 65 PERCENT UNOBSTRUCTED AND THE CEILING HEIGHT IS NOT LESS THAN 7 FEET (21 34 MM). b. EAVE PROJECTIONS SHALL NOT BE CONSIDERED AS OBSTRUCTING THE CLEAR OPEN SPACE OF A YARD OR COURT. c. REQUIRED GLAZED OPENINGS MAY FACE INTO THE AREA UNDER A DECK, BALCONY, BAY OR FLOOR d. CANTILEVER PROVIDED A CLEAR VERTICAL SPACE AT LEAST 36 INCHES (914 MM) IN HEIGHT IS PROVIDED. WHEN THE WINTER DESIGN TEMPERATURE IN TABLE R301.2(I) IS BELOW 60°F (16°C), EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE CF 68°F (20°C) AT A POINT 3 FEET (914 MM) ABOVE THE FLOOR AND 2 FEET (610 MM) FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN TEMPERATURE. THE INSTALLATION OF ONE OR MORE PORTABLE SPACE HEATERS SHALL NOT BE USED TO ACHIEVE COMPLIANCE WITH THIS SECTION. COMMON ROOM: 1 20 SF; COOKING +LIVING OR LIVING +SLEEPING: 150 SF KITCHENS ARE EXEMPT FROM MINIMUM AREA AND DIMENSIONS. SRC DEFINITION OF HABITABLE SPACE: • A SPACE IN A BUILDING FOR LIVING, SLEEPING, EATING OR COOKING. BATHROOMS, TOILET ROOMS, CLOSETS, HALLS, STORAGE OR UTILITY SPACES AND SIMILAR AREAS ARE NOT CONSIDERED HABITABLE SPACES. R305 CEILING N EIGt1T I HABITABLE SPACES/ROOMS, HALLWAYS, CORRIDORS, BATHROOM, TOILET ROOMS, LAUNDRY ROOMS AND BASEMENTS SHALL HAVE A CEILING HEIGHT NOT LESS THAN 7 FEET MEASURED FROM FINISH FLOOR TO FINISH CEILING. BEAMS AT LEAST 4 FEET ON CENTER CAN PROJECT INTO SPACE 6 INCHES. 2 SLOPED CEILINGS: NOT MORE THAN 50% OF THE REQUIRED FLOOR AREA OF A ROOM/SPACE IS PERMITTED TO HAVE A SLOPED CEILING LESS THAN 7 FEET OR A PORTION LESS THAN 5 FEET, (I.E. MINIMUM REQUIRED BEDROOM IS 70 SF PER R304.3, SO AT LEAST 35 SF OF A BEDROOM NEEDS TO HAVE CEILING HEIGHTS OVER 7 FEET AND THE OTHER 35 SF OVER 5 FEET. 3 GARAGE REQUIREMENTS PER R309 4 ATTIC ACCESS PER R807 5 WEATHER PROTECTION PER R703 � R903 R307 TOILET, BATt1 � St10WER SPACES I R307. I SPACE REQUIRED. FIXTURES SHALL BE SPACED IN ACCORDANCE WITH FIGURE R307. I ,AND IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION P2705. I . 2 BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET (i 829 MM) ABOVE THE FLOOR. R308 DOORS � WI N DOWS I DOORS AS SELECTED BY OWNER, BUT MUST MEET CODE, EGRESS, HARDWARE, REQUIREMENTS AS PER BELOW: 2 SEE FLOOR PLANS FOR SIZES. RATING AND REQUIRED U-VALUES SHALL BE PER PLAN AND AS SET FORTH ON THIS SHEET. SEE SCHEDULES ATTACHED OR IN DRAWINGS. ALL EXTERIOR DOORS: WINDOWS AND SKYLIGHTS SHALL BE NFRC CERTIFIED AND SHALL MEET SEC SECTION R402.4.3. 3 ALL DWELLING UNITS SHALL HAVE DEAD -BOLTS THAT HAVE THUMB -TURN TO THE INSIDE. 4 ELECTRIC GARAGE DOOR TO BE INSTALLED BY COMPANY FAMILIAR WITH SAFETY REQUIREMENTS. 5 ALL DOORS WITH REQUIRED FIRE RATING SHALL COMPLY WITH PROVISIONS IN THIS SECTION, AND SHALL BE SELF CLOSING AND LATCHING WITH NO HOLD -OPENS. FIRE DOORS AND DAMPERS SHALL HAVE AN APPROVED LABEL OR LISTING MARK, IDENTIFYING THE FIRE -PROTECTION RATING PERMANENTLY AFFIXED AT THE FACTORY PER IBC/SBC 71 5.3.3 ALL TREATED DOORS TO HAVE 3 HINGES PER LEAF. WHEN SPRING HINGES ARE USED FOR SELF -CLOSING REQUIREMENTS, NOT LESS THAN HALF OF THE HINGES ARE TO BE SPRING HINGES. 6 ALL GLAZING WITHIN 24" OF A DOOR, OR WITHIN 18" FROM A FLOOR SURFACE TO BE TEMPERED, INCLUDING ANY GLASS SHOWER OR TUB DOORS. ADDITIONALLY, GLAZING WITHIN 5 FEET OF THE BOTTOM OR TOP OF STAIRWAYS WHERE THE SILL IS LESS THAN 60" AFF SHALL BE SAFETY GLAZED. IRC R308.3 � 308.4 SPECIFIES OTHER HAZARDOUS LOCATIONS ALSO REQUIRING SAFETY GLAZING. 7 EGRESS WINDOWS FROM SLEEPING ROOMS AND BASEMENTS WITH HABITABLE SPACE W/O SLEEPING ROOM TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SF, MINIMUM OF 24" CLEAR HEIGHT, 20" MINIMUM CLEAR WIDTH, WITH MAXIMUM SILL HEIGHT OF 44" ABOVE FINISHED FLOOR PER IRC R310. 8 SKYLIGHTS PER R308.6 9 ALL DOORS CENTERED IN OPENINGS OR HALLWAYS OR WITH MINIMUM 4" RETURNS, UNLESS NOTED OTHERWISE. R3 I O. I EMERGENCY ESCAPE � RESCUE I BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES (I 118 MM) ABOVE THE FLOOR. WHERE A DOOR OPENING HAVING A THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES AS AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEAD ENCLOSURE SHALL COMPLY WITH SECTION R310.3. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. a.EXCEPTION: BASEMENTS USED ONLY TO HOUSE MECHANICAL EQUIPMENT AND NOT EXCEEDING TOTAL FLOOR AREA OF 200 SQUARE FEET (18.58 M2). 2 ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET {0.530 M 2). a. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M2). 3 THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES (6 I O MM). 4 THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES (508 MM). 5 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. I THE MINIMUM HORIZONTAL AREA OF THE WINDOW WELL SHALL BE 9 SQUARE FEET {0.9 M2), WITH A MINIMUM HORIZONTAL PROJECTION AND WIDTH OF 36 INCHES (914 MM). THE AREA OF THE WINDOW WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE FULLY OPENED. a. EXCEPTION: THE LADDER OR STEPS REQUIRED BY SECTION R310.2. I SHALL BE PERMITTED TO ENCROACH A MAXIMUM OF 6 INCHES (1 52 MM) INTO THE REQUIRED DIMENSIONS OF THE WINDOW WELL. 2 WINDOW WELLS WITH A VERTICAL DEPTH GREATER THAN 44 INCHES (I 118 MM) SHALL BE EQUIPPED WITH A PERMANENTLY AFFIXED LADDER OR STEPS USABLE WITH THE WINDOW IN THE FULLY OPEN POSITION. LADDERS OR STEPS REQUIRED BY THIS SECTION SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS R31 I .7 AND R31 I .8. LADDERS OR RUNGS SHALL HAVE AN INSIDE WIDTH OF AT LEAST 12 INCHES (305 MM), SHALL PROJECT AT LEAST 3 INCHES {76 MM) FROM THE WALL AND SHALL BE SPACED NOT MORE THAN 18 INCHES (457 MM) ON CENTER VERTICALLY FOR THE FULL HEIGHT OF THE WINDOW WELL. I ALL DWELLINGS SHALL BE PROVIDED WITH A MEANS OF EGRESS AS PROVIDED IN THIS SECTION. THE MEANS OF EGRESS SHALL PROVIDE A CONTINUOUS AND UNOBSTRUCTED PATH OF VERTICAL AND HORIZONTAL EGRESS TRAVEL FROM ALL PORTIONS OF THE DWELLING TO THE EXTERIOR OF THE DWELLING AT THE REQUIRED EGRESS DOOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. 2 AT LEAST ONE EGRESS DOOR SHALL BE PROVIDED FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE SIDE -HINGED, AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 INCHES (813 MM) WHEN MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES (I .57 RAD). THE MINIMUM CLEAR HEIGHT OF THE DOOR OPENING SHALL NOT BE LESS THAN 78 INCHES (I 981 MM) IN HEIGHT MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM DIMENSIONS. EGRESS DOORS SHALL BE READILY OPERABLE FROM INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 3 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36 INCHES {914 MM) MEASURED IN THE DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCEED I/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT). a. EXCEPTION: EXTERIOR BALCONIES LESS THAN 60 SQUARE FEET (5.6 M2) AND ONLY ACCESSIBLE FROM A DOOR ARE PERMITTED TO HAVE A LANDING LESS THAN 36 INCHES (91 4 MM) MEASURED IN THE DIRECTION OF TRAVEL. 4 LANDINGS OR FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN I I/2 INCHES (38 MM) LOWER THAN THE TOP OF THE THRESHOLD. a. EXCEPTION: THE EXTERIOR LANDING OR FLOOR SHALL NOT BE MORE THAN 7 3/4 INCHES { 196 MM) BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. 5 THE MINIMUM WIDTH OF A HALLWAY SHALL BE NOT LESS THAN 3 FEET (914 MM). R3 I I .7 STAIRWAYS I STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES (914 MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5 INCHES (I 14 MM) ON EITHER SIDE OF THE STAIRWAY AND THE MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL NOT BE LESS THAN 31 I/2 INCHES (787 MM) WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698 MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. a. EXCEPTION: THE WIDTH OF SPIRAL STAIRWAYS SHALL BE IN ACCORDANCE WITH SECTION R31 I .7.9. I . 2 THE MINIMUM HEADROOM IN ALL PARTS OF THE STAIRWAY SHALL NOT BE LESS THAN 6 FEET 8 INCHES (2032 MM) MEASURED VERTICALLY FROM THE SLOPED LINE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF THE LANDING OR PLATFORM ON THAT PORTION OF THE STAIRWAY. a. EXCEPTION: WHERE THE NOSINGS OF TREADS AT THE SIDE OF A FLIGHT EXTEND UNDER THE EDGE OF A FLOOR OPENING THROUGH WHICH THE STAIR PASSES, THE FLOOR OPENING SHALL BE ALLOWED TO PROJECT HORIZONTALLY INTO THE REQUIRED HEADROOM A MAXIMUM OF 4 3/4 INCHES (I 21 MM). 3 THE WALKLINE ACROSS WINDER TREADS SHALL BE CONCENTRIC TO THE CURVED DIRECTION OF TRAVEL THROUGH THE TURN AND LOCATED 12 INCHES (305 MM) FROM THE SIDE WHERE THE WINDERS ARE NARROWER. THE 12-INCH (305 MM) DIMENSION SHALL BE MEASURED FROM THE WIDEST POINT OF THE CLEAR STAIR WIDTH AT THE WALKING SURFACE OF THE WINDER. IF WINDERS ARE ADJACENT WITHIN THE FLIGHT, THE POINT OF THE WIDEST CLEAR STAIR WIDTH OF THE ADJACENT WINDERS SHALL BE USED. 4 STAIR TREADS AND RISERS SHALL MEET THE REQUIREMENTS OF THIS SECTION. FOR THE PURPOSES OF THIS SECTION ALL DIMENSIONS AND DIMENSIONED SURFACES SHALL BE EXCLUSIVE OF CARPETS, RUGS OR RUNNERS. 5 THE MAXIMUM RISER HEIGHT SHALL BE 7 3/4 INCHES (196 MM). THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). 6 THE MINIMUM TREAD DEPTH SHALL BE 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). CONSISTENTLY SHAPED WINDERS AT THE WALKLINE SHALL BE ALLOWED WITHIN THE SAME FLIGHT OF STAIRS AS RECTANGULAR TREADS AND DO NOT HAVE TO BE WITHIN 3/8 INCH (9.5 MM) OF THE RECTANGULAR TREAD DEPTH. WINDER TREADS SHALL HAVE A MINIMUM TREAD DEPTH OF 10 INCHES (254 MM) MEASURED BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AT THE INTERSECTIONS WITH THE WALKLINE. WINDER TREADS SHALL HAVE A MINIMUM TREAD DEPTH OF 6 INCHES (I 52MM) AT ANY POINT WITHIN THE CLEAR WIDTH OF THE STAIR. WITHIN ANY FLIGHT OF STAIRS, THE LARGEST WINDER TREAD DEPTH AT THE WALKLINE SHALL NOT EXCEED THE SMALLEST WINDER TREAD BY MORE THAN 3/8 INCH (9.5 MM). 7 THE RADIUS OF CURVATURE AT THE NOSING SHALL BE NO GREATER THAN 9/16 INCH (14 MM). A NOSING NOT LESS THAN 3/4 INCH (19 MM) BUT NOT MORE THAN I I/4 INCHES (32 MM) SHALL BE PROVIDED ON STAIRWAYS WITH SOLID RISERS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST NOSING PROJECTION BY MORE THAN 3/8 INCH (9.5 MM) BETWEEN TWO STORIES, INCLUDING THE NOSING AT THE LEVEL OF FLOORS AND LANDINGS. BEVELING OF NOSINGS SHALL NOT EXCEED I/2 INCH (I 2.7 MM). RISERS SHALL BE VERTICAL OR SLOPED UNDER THE TREAD ABOVE FROM THE UNDERSIDE OF THE NOSING ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAD) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED, PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT PERMIT THE PASSAGE OF A 4-INCH DIAMETER (102 MM) SPHERE. EXCEPTIONS: a. A NOSING IS NOT REQUIRED WHERE THE TREAD DEPTH IS A MINIMUM OF I I INCHES (279 MM). b. THE OPENING BETWEEN ADJACENT TREADS IS NOT LIMITED ON STAIRS WITH A TOTAL RISE OF 30 INCHES (762MM) OR LESS. 8 EXTERIOR WOOD/PLASTIC COMPOSITE STAIR TREADS. WOOD/PLASTIC COMPOSITE STAIR TREADS SHALL COMPLY WITH THE PROVISIONS OF SECTION R3 17.4. I THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. A FLIGHT OF STAIRS SHALL NOT HAVE A VERTICAL RISE LARGER THAN 12 FEET (3658 MM) BETWEEN FLOOR LEVELS OR LANDINGS. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE WIDTH OF THE STAIRWAY SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36 INCHES (91 4 MM) MEASURED IN THE DIRECTION OF TRAVEL. a. EXCEPTION: A FLOOR OR LANDING IS NOT REQUIRED AT THE TOP OF AN INTERIOR FLIGHT OF STAIRS, INCLUDING STAIRS IN AN ENCLOSED GARAGE, PROVIDED A DOOR DOES NOT SWING OVER THE STAIRS. 2 THE WALKING SURFACE OF TREADS AND LANDINGS OF STAIRWAYS SHALL BE SLOPED NO STEEPER THAN ONE UNIT VERTICAL IN 48 INCHES HORIZONTAL (2-PERCENT SLOPE). I HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT W/ FOUR OR MORE RISERS. 2 HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF RAMP SLOPE, SHALL BE NOT LESS THAN 34 IN. (864 MM) � NOT MORE THAN 38 IN. (965 MM). EXCEPTIONS: a. THE USE OF A VOLUTE, TURNOUT OR STARTING EASING SHALL BE ALLOWED OVER THE LOWEST TREAD. b. WHEN HANDRAIL FITTINGS OR BEN DINGS ARE USED TO PROVIDE CONTINUOUS TRANSITION BETWEEN FLIGHTS, THE TRANSITION FROM HANDRAIL TO GUARDRAIL, OR USED AT THE START OF A FLIGHT, THE HANDRAIL HEIGHT AT THE FITTINGS OR BENDINGS SHALL BE PERMITTED TO EXCEED THE MAXIMUM HEIGHT. 3 CONTINUITY. HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN I I/2 INCH (38 MM) BETWEEN THE WALL AND THE HANDRAILS. EXCEPTIONS: a. HANDRAILS SHALL BE PERMITTED TO BE INTERRUPTED BY A NEWEL POST AT THE TURN. b. THE USE OF A VOLUTE, TURNOUT, STARTING EASING OR STARTING NEWEL SHALL BE ALLOWED OVER THE LOWEST TREAD. 4 GRIP-S17_F. ALL REQUIRED HANDRAILS SHALL BE OF ONE OF THE FOLLOWING TYPES OR PROVIDE EQUIVALENT GRASPABILITY. a. TYPE I. HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST I -I/2 INCHES (32 MM) AND NOT GREATER THAN 2 INCHES (5 I MM). IF THE HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4 INCHES (102 MM) AND NOT GREATER THAN 6 I/4 INCHES (160 MM) WITH A MAXIMUM CROSS SECTION OF DIMENSION OF 2 I/4 INCHES (57 MM). EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01 INCH (0.25 MM). b. TYPE II. HANDRAILS WITH A PERIMETER GREATER THAN 6 I/4 INCHES (I 60 MM) SHALL HAVE A GRASPABLE FINGER RECESS AREA ON BOTH SIDES OF THE PROFILE. THE FINGER RECESS SHALL BEGIN WITHIN A DISTANCE OF 3/4 INCH (I 9 MM) MEASURED VERTICALLY FROM THE TALLEST PORTION OF THE PROFILE AND ACHIEVE A DEPTH OF AT LEAST 5/I 6 INCH (8 MM) WITHIN 7/8 INCH (22 MM) BELOW THE WIDEST PORTION OF THE PROFILE. THIS REQUIRED DEPTH SHALL CONTINUE FOR AT LEAST 3/8 INCH (10 MM) TO A LEVEL THAT IS NOT LESS THAN I 3/4 INCHES (45 MM) BELOW THE TALLEST PORTION OF THE PROFILE. THE MINIMUM WIDTH OF THE HANDRAIL ABOVE THE RECESS SHALL BE I I /4 INCHES (32 MM) TO A MAXIMUM OF 2 3/4 INCHES (70 MM). EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01 INCH (0.25 MM). R31 2.2. I WINDOW SILLS. IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WINDOW OPENING IS LOCATED LESS THAN 24 INCHES (610 MM) ABOVE THE FINISHED FLOOR AND GREATER THAN 72 INCHES (I 829 MM) ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE WINDOW SHALL COMPLY WITH ONE OF THE FOLLOWING: I OPERABLE WINDOWS WITH OPENINGS THAT WILL NOT ALLOW A 4-INCH-DIAMETER (102 MM) SPHERE TO PASS THROUGH THE OPENING WHERE THE OPENING IS IN ITS LARGEST OPENED POSITION. 2 OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT COMPLY WITH ASTM F 2090 3 OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH SECTION 831 2.2.2. R31 2.2.2 WINDOW OPENING CONTROL DEVICES. WINDOW OPENING CONTROL DEVICES SHALL COMPLY WITH ASTM F 2090. THE WINDOW OPENING CONTROL DEVICE, AFTER OPERATION TO RELEASE THE CONTROL DEVICE ALLOWING THE R31 2.2.2 WINDOW OPENING CONTROL DEVICES. WINDOW OPENING CONTROL DEVICES SHALL COMPLY WITH ASTM F 2090. THE WINDOW OPENING CONTROL DEVICE, AFTER OPERATION TO RELEASE THE CONTROL DEVICE ALLOWING THE WINDOW TO FULLY OPEN, SHALL NOT REDUCE THE NET CLEAR OPENING AREA OF THE WIN-DOW UNIT TO LESS THAN THE AREA REQUIRED BY SECTION R310.2.1. I GUARDS SHALL BE LOCATED ALONG OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 MM) HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD. 2 REQUIRED GUARDS AT OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 42 INCHES (914 MM) HIGH MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE, ADJACENT FIXED SEATING OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS. EXCEPTIONS: a. GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT NOT LESS THAN 34 INCHES (8G4 MM) MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. b. WHERE THE TOP OF THE GUARD ALSO SERVES AS A HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL NOT BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM) MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. U.N.O /� ATELI E R PROJECT JONATHAN CASTILLO ADDRESS 7216 SOUNDVIEW DR EDMONDS, WA 98026 DATE 20-07-20 KA-N-01 3 REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES (I 02 MM) IN DIAMETER. EXCEPTIONS: a. THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF A STAIR, FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES (I 53 MM) IN DIAMETER. b. GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENINGS WHICH ALLOW PASSAGE OF A SPHERE 4 3/8 INCHES (III MM) IN DIAMETER. 4 GUA D ILS AND HAND ILS TO WITHSTAND A 200 LB F CONCRNT TED LOAD APPLIED IN ANY DI ECTION AT ANY POINT R RA RA /S RA R ALONG THE TOP. GUARDRAIL IN -FILL COMPONENTS (ALL THOSE EXCEPT THE HANDRAIL), BALUSTERS AND PANEL FILLERS SHALL BE DESIGNED TO WITHSTAND A HORIZONTALLY APPLIES NORMAL LOAD OF 50 LBS ON AN AREA EQUAL TO I SQUARE FOOT. THIS LOAD NEED NOT BE ASSUMED TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD REQUIREMENT. HANDRAILS TO BE BETWEEN I - I /2" DI A. AND 2" DIA. WITH CLEARANCE OF I - I /2" BETWEEN RAIL AND WALL SURFACE. MOUNT BETWEEN 34" AN D 38" OFF STAIR NOSING. r � . � � r I ALL SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 21 7 AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. 2 HOUSEHOLD FIRE ALARM SYSTEMS INSTALLED IN ACCORDANCE WITH NFPA 72 THAT INCLUDE SMOKE ALARMS, OR A COMBINATION OF SMOKE DETECTOR AND AUDIBLE NOTIFICATION DEVICE INSTALLED AS REQUIRED BY THIS SECTION FOR SMOKE ALARMS, SHALL BE PERMITTED. THE HOUSEHOLD FIRE ALARM SYSTEM SHALL PROVIDE THE SAME LEVEL OF SMOKE DETECTION AND ALARM AS REQUIRED BY THIS SECTION FOR SMOKE ALARMS. WHERE A HOUSEHOLD FIRE WARNING SYSTEM IS INSTALLED USING A COMBINATION OF SMOKE DETECTOR AND AUDIBLE NOTIFICATION DEVICE(S), IT SHALL BECOME A PERMANENT FIXTURE OF THE OCCUPANCY AND OWNED BY THE HOMEOWNER. THE SYSTEM SHALL BE MONITORED BY AN APPROVED SUPERVISING STATION AND BE MAINTAINED IN ACCORDANCE WITH NFPA 72. • EXCEPTION: WHERE SMOKE ALARMS ARE PROVIDED MEETING THE REQUIREMENTS OF SECTION R31 4.4. 3 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: • IN EACH SLEEPING ROOM. • OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. • ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. • WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. 4 WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. EXCEPTIONS: a. WORK INVOLVING THE EXTERIOR SURFACES OF DWELLINGS, SUCH AS THE REPLACEMENT OF ROOFING OR SIDING, OR THE ADDITION OR REPLACEMENT OF WINDOWS OR DOORS, OR THE ADDITION OF A PORCH OR DECK> ARE EXEMPT FROM THE REQUIREMENTS OF THIS SECTION. b. INSTALLATION, ALTERATION OR REPAIRS OF PLUMBING OR MECHANICAL SYSTEMS ARE EXEMPT FROM THE REQUIREMENTS OF THIS SECTION. 5 POWER SOURCE. SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FRCM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE, AND WHEN PRIMARY POWER IS INTERRUPTED, SHALL RECEIVE POWER FROM A BATTERY. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE INTERCONNECTED. EXCEPTIONS: 6 SMOKE ALARMS SHALL BE PERMITTED TO BE BATTERY OPERATED WHEN INSTALLED IN BUILDINGS WITHOUT COMMERCIAL POWER. 7 INTERCONNECTION AND HARD -WIRING OF SMOKE ALARMS IN EXISTING AREAS SHALL NOT BE REQUIRED WHERE THE ALTERATIONS OR REPAIRS DO NOT RESULT IN THE REMOVAL OF INTERIOR WALL OR CEILING FINISHES EXPOSING THE STRUCTURE., UNLESS THERE IS AN ATTIC., CRAWL SPACE OR BASEMENT AVAILABLE WHICH COULD PROVIDE ACCESS FOR HARD WIRING AND INTERCONNECTION WITHOUT THE REMOVAL OF INTERIOR FINISHES. I FOR NEW CONSTRUCTION, AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS IN DWELLING UNITS WITHIN WHICH FUEL -FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. 2 WHERE WORK REQUIRING A PERMIT OCCURS IN EXISTING DWELLINGS THAT HAVE ATTACHED GARAGES OR IN EXISTING DWELLINGS WITHIN WHICH FUEL -FIRED APPLIANCES EXIST, CARBON MONOXIDE ALARMS SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R31 5. I . 3 SINGLE STATION CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WITH UL 2034 AND SHALL BE INSTALLED IN ACCORDANCE WITH THIS CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. I PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE -TREATED IN ACCORDANCE WITH AWPA U I FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U I . A. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION. B. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES (203 MM) FROM THE EXPOSED GROUND. C. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER. D. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN I/2 INCH (I 2.7 MM) ON TOPS, SIDES AND ENDS. E. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO SLABS, AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER. F. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE -PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE WEATHER, SUCH AS CONCRETE OR MASONRY SLABS. UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE BARRIER. G. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL AND THE FURRING STRIPS OR FRAMING MEMBERS. 2 FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. 3 ALL WOOD IN CONTACT WITH THE GROUND, EMBEDDED IN CONCRETE IN DIRECT CONTACT WITH THE GROUND OR EMBEDDED IN CONCRETE EXPOSED TO THE WEATHER THAT SUPPORTS PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL BE APPROVED PRESSURE -PRESERVATIVE -TREATED WOOD SUITABLE FOR GROUND CONTACT USE, EXCEPT UNTREATED WOOD MAY BE USED WHERE ENTIRELY BELOW GROUNDWATER LEVEL OR CONTINUOUSLY SUBMERGED IN FRESH WATER. R329 SECURITY PROVIDE BUILDING ENTRANCE LOCKS AND OBSERVATION PORTS AT APPROX. 60" AFF IN ACCORDANCE WITH THIS SECTION. SOUND TRANSMISSION CONTROL PER SEATTLE RESIDENTIAL CODE SECTION R330. SECURITY FROM CRIMINAL ACTIVITY: DEAD BOLT (MIN. I/2" THROW) AND VIEWPOINT REQUIRED @EXTERIOR DOORS. WINDOWS AND SLIDING DOORS WITHIN I O' OF GRADE SHALL BE PROVIDED WITH LATCHING DEVICES, ALL LOCKS SHALL BF OPEN ABLE WITHOUT SPECIAL KNOWLEDGE OR EFFORT. A. ASSEMBLIES SEPARATING DWELLING UNITS SHALL PROVIDE: • AT WALLS: AIRBORNE SOUND INSULATION AT STC 45 (OR MORE) PER, ASTM E 90. • AT FLOOR -CEILING AIRBORNE AND IMPACT SOUND INSULATION AT AN "IMPACT INSULATION CLASS" (IIC) OR MIN. 50 PER ASTM E 492 R33 I SOUND TRANSMISSION CONTROL I ASSEMBLIES SEPARATING DWELLING UNITS SHALL PROVIDE: • AT WALLS: AIRBORNE SOUND INSULATION AT STC 50 (OR MORE) PER, ASTM E 90. • AT FLOOR -CEILING: AIRBORNE AND IMPACT SOUND INSULATION AT AN "IMPACT INSULATION CLASS" (IIC) OR MIN. 50 PER ASTM E 492 I AIR -BORNE SOUND: WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED). PENETRATIONS OR OPENINGS IN CONSTRUCTION ASSEMBLIES FOR PIPING, ELECTRICAL DEVICES, RECESSED CABINETS, BATHTUBS, SOFFITS, OR HEATING, VENTILATING OR EXHAUST DUCTS SHALL BE SEALED. LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THE REQUIRED STC. UNIT ENTRY DOORS SHALL BE TIGHT FITTING TO THE FRAME AND SILL. UNIT ENTRY DOOR ASSEMBLIES SHALL HAVE A STC OF NOT LESS THAN 28. SBC 1207.2. 2 STRUCTURE -BORNE SOUND: FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE AN IMPACT INSULATION CLASS (IOC) RATING OF NOT LESS THAN 50 (45 IF FIELD TESTED) PER 3 JOINTS IN THE PERIMETER OF WALLS OR FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL BE ACOUSTICALLY SEALED WITH A PERMANENT RESILIENT MATERIAL APPROVED FOR SUCH PURPOSE. CONDUITS, DUCTS, PIPES AND VENTS WITHIN SUCH WALL OR FLOOWCEILIN6 ASSEMBLIES CAUSING VIBRATION SHALL BE REASONABLY ISOLATED FROM THE BUILDING CONSTRUCTION AT POINTS OF SUPPORT. ALL OPENINGS THROUGH WHICH SUCH ITEMS PASS SHALL HAVE THE EXCESS OPENING FULLY SEALED. SBC 1207.3. 4 ELECTRICAL OUTLET BOXES SHALL NOT BE PLACED BACK-TO-BACK AND SHALL BE OFFSET BY NOT LESS THAN 12 INCHES FROM �� OUTLETS IN THE OPPOSITE WALL SURFACE. THE BAC AND SIDES OF BOXES SHALL BE SEALED WITH 18 RESILIENT SEALANT K AND BACKED BY AT LEAST 2" THICK MATERIAL FIBER INSULATION. SBC 1207.3. 5 SPACES OR SHAFTS CONTAINING AIR CONDITIONING, REFRIGERATION OR VENTILATING EQUIPMENT, ELEVATOR MACHINERY, OR OTHER MECHANICAL EQUIPMENT SHALL BE SEPARATED BOTH VERTICALLY AND HORI7_ONTALLY FROM ADJOINING DWELLING UNITS BY CONSTRUCTION DESIGNED TO PROVIDE A MINIMUM STC RATING OF 50. SBC 1207.6. 6 DESIGN AND MATERIALS FOR SOUND TRANSMISSION CONTROL SHALL NOT IMPAIR THE FIR;= -RESISTANT INTEGRITY OF SEPARATING WALLS OR FLOOR/CEILING ASSEMBLIES. a. ASSEMBLIES SEPARATING DWELLING UNITS SHALL PROVIDE: b. AT WALLS: AIRBORNE SOUND INSULATION AT STC 45 (OR MORE) PER, ASTM E 90. c. AT FLOOR -CEILING AIRBORNE AND IMPACT SOUND INSULATION AT AN "IMPACT INSULATION CLASS" (IIC) OR MIN. 50 PER ASTM E 492 r � •���1� -������� A PERMANENT CERTIFICATE SHALL BE COMPLETED AND POSTED ON OR WITHIN THREE FEET OF THE ELECTRICAL DISTRIBUTION PANEL BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL. THE CERTIFICATE SHALL BE COMPLETED BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL AND SHALL NOT COVER OR OBSTRUCT THE VISIBILITY OF THE CIRCUIT DIRECTORY LABEL, SERVICE DISCONNECT LABEL OR OTHER REQUIRED LABELS. THE CERTIFICATE SHALL LIST THE PREDOMINANT RVALUES OF INSULATION INSTALLED IN OR ON CEILING/ROOF, WALLS, FOUNDATION (SLAB, BELOW -GRADE WALL, AND/OR FLOOR) AND DUCTS OUTSIDE CONDITIONED SPACES; U-FACTORS FOR FENESTRATION AND THE RESULTS FROM ANY REQUIRED DUCT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TESTING DONE ON THE BUILDING. WHERE THERE IS MORE THAN ONE VALUE FOR EACH COMPONENT, THE CERTIFICATE SHALL LIST THE VALUE COVERING THE LARGEST AREA. THE CERTIFICATE SHALL LIST THE TYPES AND EFFICIENCIES OF HEATING, COOLING AND SERVICE WATER HEATING EQUIPMENT. I R402.4.3 AIR LEAKAGE OF FENESTRATION. WINDOWS, SKYLIGHTS AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FOOT (I .5 L/S/M2), AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FOOT (2.G US/M2), WHEN TESTED ACCORDING TO NFRC 400 OR AAMAMlDMA/CSA I01/I.S.2/A440 BY AN ACCREDITED, INDEPENDENT LABORATORY AND LISTED AND LABELED BY THE MANUFACTURER. 2 R402.4.4 RECESSED LIGHTING. RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE TYPE IC - RATED AND CERTIFIED UNDER ASTM E283 AS HAVING AN AIR LEAKAGE RATE NOT MORE THAN 2.0 CFM (0.944 L/S) WHEN TESTED AT A I .57 PSF (75 PA) PRESSURE DIFFERENTIAL AND SHALL HAVE A LABEL ATTACHED SHOWING COMPLIANCE WITH THIS TEST METHOD. ALL RECESSED LUMINAIRES SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING � THE INTERIOR WALL OR CEILING COVERING. 3 502.4.5 BUILDING AIR LEAKAGE TESTING: BUILDING ENVELOPE AIR LEAKAGE CONTROL SHALL BE CONSIDERED ACCEPTABLE WHEN TESTED TO HAVE AN AIR LEAKAGE TO NOT EXCEED 5 AIR CHANGES /HOUR WHEN TESTED WITH A BLOWER DOOR AT A PRESS OF 50 PASCALS (0.2 INCH W.G.). TESTING SHALL OCCUR AT ANY TIME AFTER ROUGH IN � AFTER INSTALLATION OF PENETRATIONS OF THE BUILDING ENVELOPE, INCLUDING PENETRATIONS FOR UTILITIES, PLUMBING, ELECTRICAL, VENTILATION � COMBUSTION APPLIANCES � SEALING THEREOF. WHEN REQUIRED BY THE BUILDING OFFICIAL, THE TEST SHALL BE CONDUCTED IN THE PRESENCE OF DEPARTMENT STAFF. THE BLOWER DOOR TEST RESULTS SHALL BE RECORDED ON THE CERTIFICATE REQUIRED IN SECT. 105.4. EXCEPTIONS: I .ADDITIONS LESS THAN 500 SQUARE FEET. 2. ONCE VISUAL INSPECTION HAS CONFIRMED THE PRESENCE OF A GASKET (SEE SECTION 502.4}, OPERABLE WINDOWS AND DOORS MANUFACTURi=D BY SMALL BUSINESS SHALL BE PERMITTED TO BE SEALED OFF AT THE FRAME PRIOR TO THE TEST. 3. SPECIFIC LEAKAGE AREA (SLA) SHALL BE CALCULATED AS FOLLOWS: SLA = (CFM50 X 0.055}!(CFAX 144). WHERE: 4. CFM50 =BLOWER DOOR FAN FLOW AT 50 PASCAL PRESSURE DIFFERENCE 5. CFA =CONDITIONED FLOOR AREA OF THE HOUSING UNIT DURING TESTING: I .EXTERIOR WINDOWS AND DOORS, FIREPLACE AND STOVE DOORS SHALL BE CLOSED, BUT NOT SEALED. 2. DAMPERS SHALL BE CLOSED, BUT NOT SEALED; INCLUDING EXHAUST, INTAKE, MAKEUP AIR, BACK DRAFT; AND FLUE DAMPERS; 3. INTERIOR DOORS CONNECTING CONDITIONED SPACES SHALL BE OPEN; ACCESS HATCHES TO CONDITIONED CRAWL SPACES AND CONDITIONED ATTICS SHALL BE OPEN; DOORS CONNECTING TO UNCONDITIONED SPACES SHALL BE CLOSED BUT NOT SEALED; 4. EXTERIOR OPENINGS FOR CONTINUOUS OPERATION VENTILATION SYSTEMS AND HEAT RECOVERY VENTILATORS SHALL BE CLOSED AND SEALED; 5. HEATING AND COOLING SYSTEMS) SHALL BE TURNED OFF; G. I-IVAC DUCTS SUPPLY AND RETURN REGISTERS SHALL NOT BE SEALED. A WRITTEN REPORT OF THE TEST RESULTS SHALL BE SIGNED BY THE TESTING PARTY AND PROVIDED TO THE BUILDING INSPECTOR PRIOR TO CALL FOR FINAL INSPECTION. R403 DUCTS � PIPING • DUCTS AND AIR HANDLERS SHALL BE IN ACCORDANCE WITH SECTIONS R403.2. I THROUGH R403.2.3. • R403.2. I INSULATION (PRESCRIPTIVE). DUCTS SHALL BE INSULATED TO A MINIMUM OF R-8. EXCEPTION: DUCTS OR PORTIONS THEREOF LOCATED COMPLETELY INSIDE THE BUILDING THERMAL ENVELOPE. DUCTS LOCATED IN CRAWL SPACES DO NOT QUALIFY FOR THIS EXCEPTION. • R403.2.2 SEALING (MANDATORY). DUCTS., AIR HANDLERS, AND FILTER BOXES SHALL BE SEALED. JOINTS AND SEAMS SHALL COMPLY WITH EITHER THE INTERNATIONAL MECHANICAL CODE OR INTERNATIONAL RESIDENTIAL CODE, AS APPLICABLE. • EXCEPTIONS: I AIR -IMPERMEABLE SPRAY FOAM PRODUCTS SHALL BE PERMITTED TO BE APPLIED WITHOUT ADDITIONAL JOINT SEALS. 2 WHERE A DUCT CONNECTION IS MADE THAT IS PARTIALLY INACCESSIBLE, THREE SCREWS OR RIVETS SHALL BE EQUALLY SPACED ON THE EXPOSED PORTION OF THE JOINT SO AS TO PREVENT A HINGE EFFECT. 3 CONTINUOUSLY WELDED AND LOCKING -TYPE LONGITUDINAL JOINTS AND SEAMS IN DUCTS OPERATING AT STATIC PRESSURES LESS THAN 2 INCHES OF WATER COLUMN (500 PA) PRESSURE CLASSIFICATION SHALL NOT REQUIRE ADDITIONAL CLOSURE SYSTEMS. • DUCTS SHALL BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33. USING THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED. DUCT TIGHTNESS SHALL BE VERIFIED BY EITHER OF THE FOLLOWING: I POSTCONSTRUCTION TEST: TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 4 CFM PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA WHEN TESTED AT A PRESSURE DIFFERENTIAL OF 0.1 INCHES W.G. (25 PA} ACROSS THE ENTIRE SYSTEM, INCLUDING THE MANUFACTURER'S AIR HANDLER ENCLOSURE. ALL REGISTER BOOTS SHALL BE TAPED OR OTHERWISE SEALED DURING THE TEST. LEAKAGE TO OUTDOORS SHALL BE LESS THAN OR EQUAL TO 4 CFM PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA. 2 ROUGH -IN TEST: TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 4 CFM PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA WHEN TESTED AT A PRESSURE DIFFERENTIAL OF 0.1 INCHES W.G. (25 PA) ACROSS THE SYSTEM, INCLUDING THE MANUFACTURER'S AIR HANDLER ENCLOSURE. ALL REGISTERS SHALL BE TAPED OR OTHERWISE SEALED DURING THE TEST. IF THE AIR HANDLER IS NOT INSTALLED AT THE TIME OF THE TEST, TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 3 CFM (85 L/MIN) PER 100 SQUARE FEET (9.29 M2) OF CONDITIONED FLOOR AREA. 3 EXCEPTION: THE TOTAL LEAKAGE TEST IS NOT REQUIRED FOR DUCTS AND AIR HANDLERS LOCATED ENTIRELY WETHIN THE BUILDING THERMAL ENVELOPE. DUCTS LOCATED IN CRAWL SPACES DO NOT QUALIFY FOR THIS EXCEPTION. • R403.2.2. I SEALED AIR HANDLER. AIR HANDLERS SHALL HAVE A MANUFACTURER'S DESIGNATION FOR AN AIR LEAKAGE OF NO MORE THAN 2 PERCENT OF THE DESIGN AIR FLOW RATE WHEN TESTED IN ACCORDANCE WITH ASHRAE 193. • R403.2.3 BUILDING CAVITIES (MAN DATORY).BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS. INSTALLATION OF DUCTS IN EXTERIOR WALLS, FLOORS ORCEILINGS SHALL NOT DISPLACE REQUIRED ENVELOPE INSULATION. • R403.3 MECHANICAL SYSTEM PIPING INSULATION (MANDATORY). MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE 105°F OR BELOW 55°F SHALL BE INSULATED TO A MINIMUM OF R-C. • R403.3.1 PROTECTION OF PIPING INSULATION. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT CAUSED BY SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE, AND WIND, AND SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. ADHESIVE TAPE SHALL NOT BE PERMITTED. • R403.4 SERVICE HOT WATER SYSTEMS. ENERGY CONSERVATION MEASURES FOR SERVICE HOT WATER SYSTEMS SHALL BE IN ACCORDANCE WITH SECTIONS R403.4.1 THROUGH R403.4.3. • R403.4. I CIRCULATING HOT WATER SYSTEMS (MANDATORY). CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED WITH AN AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT WATER CIRCULATING PUMP WHEN THE SYSTEM IS NOT IN USE. • R403.4.2 HOT WATER PIPE INSULATION (PRESCRIPTIVE). INSULATION FOR HOT WATER PIPE SHALL HAVE A MINIMUM THERMAL RESISTANCE (R-VALUE) OF R-4. R403. I TEMPERATURE CONTROL I R403.1 CONTROLS (MANDATORY). AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND COOLING SYSTEM. a. R403. I . I PROGRAMMABLE THERMOSTAT. WHERE THE PRIMARY HEATING SYSTEM IS A FORCED -AIR FURNACE, AT LEAST ONE THERMOSTAT PER DWELLING UNIT SHALL BE CAPABLE OF CONTROLLING THE HEATING AND COOLING SYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT DIFFERENT TIMES OF THE DAY. THE THERMOSTAT SHALL ALLOW FOR, AT A MINIMUM, A 5-2 PROGRAMMABLE SCHEDULE (WEEKDAYS/WEEKENDS) AND BE CAPABLE OF PROVIDING AT LEAST TWO PROGRAMMABLE SETBACK PERIODS PER DAY. THIS THERMOSTAT SHALL INCLUDE THE CAPABILITY TO SET BACK OR TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55°F (13°C) OR UP TO 85°F (29°C). THE THERMOSTAT SHALL INITIALLY BE PROGRAMMED WITH A HEATING TEMPERATURE SET POINT NO HIGHER THAN 70°F(21 °C) AND A COOLING TEMPERATURE SET POINT NO LOWER THAN 78°F (26°C). THE THERMOSTAT AN D/OR CONTROL SYSTEM SHALL HAVE AN ADJUSTABLE DEADBAND OF NOT LESS THAN I 0°F. b. R403. I .2 HEAT PUMP SUPPLEMENTARY HEAT (MANDATORY). UNITARY AIR COOLED HEAT PUMPS SHALL INCLUDE CONTRCLS THAT MINIMIZE SUPPLEMENTAL HEAT USAGE DURING START-UP, SET-UP, AND DEFROST CONDITIONS. THESE CONTROLS SHALL ANTICIPATE NEED FOR HEAT AND USE COMPRESSION HEATING AS THE FIRST STAGE OF HEAT. CONTROLS SHALL INDICATE WHEN SUPPLEMENTAL HEATING IS BEING USED THROUGH VISUAL MEANS (E.G., LED INDICATORS). HEAT PUMPS EQUIPPED WITH SUPPLEMENTARY HEATERS SHALL BE INSTALLED WITH CONTROLS THAT PREVENT SUPPLEMENTAL HEATER OPERATION ABOVE 40°F. AT FINAL INSPECTION THE AUXILIARY HEAT LOCK OUT CONTROL SHALL BE SET TO 35°F OR LESS. R404 LIGHTING � ELECTRICAL R404.1 LIGHTING EQUIPMENT (MANDATCRY) -SEC 606 AND SEC 505. I • INTERIOR LIGHTING: MIN. 75%OF LIGHTING FIXTURES TO BE HIGH EFFICACY (PIN -BASED) • EXTERIOR LIGHTING :ALL LIGHTING FIXTURES TO BE HIGH EFFICACY (PIN BASED) I ELECTRICAL WORK SHALL BE PERFORMED IN A "BIDDER -DESIGN" MANNER. THE CONTRACTOR SHALL SUBMIT SUCH SYSTEMS SEPARATELY FOR PERMIT. 2 IT IS THE CONTRACTOR'S RESPONSIBILITY TO DESIGN SYSTEMS THAT MEET ALL REQUIREMENTS AND CODES. CONTRACTOR SHALL SUBMIT DRAWINGS, PAY FOR, AND OBTAIN PERMIT AND PERFORM WORK IN A MANNERTHAT MEETS OR EXCEEDS THE RECOGNIZED WORKMANSHIP STANDARDS FOR THE INDUSTRY. 3 ALL DRAWINGS ARE TO BE SUBMITTED FOR REVIEW AND APPROVAL TO THE OWNER BEFORE PERFORMING WORK. SPECIFIC ATTENTION IS TO BE PAID REGARDING OWNER -REQUESTED LOCATIONS OF ELECTRICAL, PHONE AND COMPUTER CABLING PORT LOCATIONS. 4 PROPER PROTECTION SHALL BE PROVIDED AROUND RECESSED LIGHT FIXTURES PER MANUFACTURER'S RECOMMENDATIONS SO THAT OVERHEATING WILL NOT OCCUR. RECESSED LIGHT FIXTURES TO BE IC RATED. I CLASS 1 OR II VAPOR RETARDERS ARE REQUIRED FOR INTERIORSIDE OF FRAME WALLS FOR7.ONE 4. EXCEPTIONS: a. BASEMENT WALLS b. BELOW GRADE PORTION OF ANY EXTERIOR WALL. c. CONSTRUCTION WHERE MOISTURE OR FREE7_ING WILL NOT DAMAGE THE MATERIALS. 2 CLASS III VAPOR RETARDERS SHALL BE PERMITTED WHERE ANY ONE OF THE CONDITIONS IN TABLE R601 .3. I IS MET. 3 MATERIAL VAPOR RETARDER CLASS SHALL BE BASE ON THE MANUFACTURER'S CERTIFIED TESTING ORTESTIN6 ASSEMBLY. • THE FOLLOWING SHALL BE DEEMED TO MEET THE CLASS SPECIFIED: • CLASS I :SHEET POLYPROPYLENE, UNPERFORATED ALUMINUM FOIL. • CLASS II: KRAFT-FACED FIBERGLASS BATTS. • CLASS III: LATEX OR ENAMEL PAINT. 4 VENTED CLADDING SHALL INCLUDE THE FOLLOWING MINIMUM CLEAR AIR SPACES. OTHER OPENINGS WITH THE EQUIVALENT VENT AREA SHALL BE PERMITTED. a. VINYL LAP OR HORIZONTAL ALUMINUM SIDING APPLIED OVER A WEATHER RESISTIVE BARRIER AS SPECIFIED IN TABLE R703.4. b. BRICK VENEER WITH A CLEAR AIRSPACE AS SPECIFIED IN SECTION R703.7.4.2. c. OTHER APPROVED VENTED CLADDINGS. I PROVIDEI/2" GYPSUM WALL BOARD FOR NON -RATED ASSEMBLIES AND 5/8" TYPE "X" GYPSUM WALL BOARD FOR I -HOUR RATED ASSEMBLIES WITH ALL EXPOSED JOINTS AND FASTENER HEADS SMOOTH AND FLUSH WITH SURFACE OF BOARD. JOINTS TAPED AND PREPARED FOR APPLICATION OF FINISH. USE WATER-RESISTANT BOARD AT ALL WET AREAS TO 4'-0" AFF. 2 "RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD," LATEST EDITION, AS PUBLISHED BY THE GYPSUM ASSOCIATION (ALSO PUBLISHED AS ANSI 97. I AND "USING GYPSUM BOARD AND CEILING," LATEST EDITION). 3 WHEN GYPSUM BOARD IS USED AS A BASE FOR TILE OR WALL PANELS FOR TUB, SHOWER OR WATER CLOSET COMPARTMENT WALLS, WATER RESISTANT GYPSUM BACKING BOARD SHALL BE USED PER SRC SECTION R702.4.2. . : � APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN SUCH A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 771 . THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: I EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. 2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS 3 UNDERAND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5 WHERE EXTERIOR PORCHES, DECK OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. 6 AT WALL AND ROOF INTERSECTIONS. 7 AT BUILT-IN GUTTERS. GENERAL FLASHING NOTES I ALL FLASHING SYSTEMS SHALL CONFORM WITH APPLICABLE CODES AND S.M.A.C.N.A. STANDARDS. ALL MATERIALS USED SHALL BE APPROVED FOR SUCH USE. ALL METALS USED SHALL BE OF APPROPRIATE COMPOSITION AND THICKNESS. ALL FLASHING FABRICATION SHALL BE PREFORMED BY A SMACNA APPROVED PROFESSIONAL CONTRACTOR / FABRICATOR. ALL FLASHINGS SHALL BE REVIEW AND APPROVED BY THE PROJECT ARCHITECT PRIOR TO FABRICATION. ALL SOLDERED JOINTS SHALL BE PRETESTED PRIOR TO FLASHING INSTALLATION. 2 DOOR AND WINDOW HEAD FLASHING: FLASHING EXTENDS UP THE WALL A MINIMUM OF 4 INCHES AND BEYOND THE OPENING A MINIMUM OF 4 INCHES EACH SIDE. FLASHING SHALL EXTEND OUT OVER FRAME OF WINDOW OR DOOR TRIM WITH A SLOPED SECTION HAVING END DAMS AND CONTINUE DOWN THE FACE OF FRAME ORTRIM A MINIMUM OF I/2 INCH. FLASHING SHALL TERMINATE WITH A CLEAT OR HEMMED DRIP EDGE. ALL FLASHING SHALL BE BENT OR SOLDERED AT ALL INTERSECTIONS. 3 ONE LAYER OF SELF ADHERING FLASHING SHALL PRECEDE THE INSTALLATION OF METAL FLASHING -LAPPING WINDOW FLANGE OR DOOR FRAME AND EXTEND ABOVE THE TOP OF METAL FLASHING I INCH AND BEYOND THE SIDES OF THE METAL FLASHING BY ONE INCH. 4 ONCE METAL FLASHING HA5 BEEN INSTALLED A SECOND LAY OF SELF ADHERING FLASHING SHALL BE APPLIED. THIS FLASHING SHALL LAP METAL FLASHING A MINIMUM OF 3 INCHES AND LAP UP WALL 3 INCHES AND 3 INCHES BEYOND EACH SIDE. 5 TWO LAYERS OF BUILDING PAPER OR APPROVED HOUSE WRAP SHALL THEN BE APPLIED TO EXTERIOR. 6 DOOR AND WINDOW JAMB FLASHING: JAMB FLASHING SHALL BE MADE UP OF SELF ADHERING FLEXIBLE FLASHING. THIS FLEXIBLE FLASHING SHALL TUCK UNDER HEAD FLASHING ABOVE AND OVER SILL FLASHING BELOW. JAMB FLASHING WILL LAP OVER EXTERIOR FACE OF WALL A MINIMUM OF 2 INCHES (OVER THE TWO LAYERS OF BUILDING PAPER AND ONE LAYER OF UN - ADHESIVE FLEXIBLE FLASHING HAVING A MINIMUM WIDTH OF 9 INCHES.) AT WINDOWS A SECOND LAYER OF SELF ADHERING FLEXIBLE FLASHING SHALL BE APPLIED OVER WINDOW FLANGE -LAPPING FLANGE FULLY AND EXTENDING BEYOND FIRST LAYER OF FLASHING BY TWO INCHES HORIZONTALLY. 7 BLOCKING USE AT DOOR OR WINDOW JAMBS SHALL BE FULL DEPTH OF THE FRAME AND SLOPE TO THE EXTERIOR. B DOOR AND WINDOW SILL FLASHING: FLASHING SILL SHALL BE SLOPED I/8 INCH PER INCH OF DEPTH TOWARD EXTERIOR. DEPTH OF FLASHING SHALL BE INTERIOR OF WINDOW FRAME I/4 INCH TO ALLOW FOR SEALANT AT THIS LOCATION. DEPTH OF FLASHING SHALL BE DETERMINED BY THE DEPTH OF THE DOOR THRESHOLD -WITH THE SILL FLASHING TERMINATING UNDER THE THRESHOLD. SILL FLASHING SHALL HAVE A MINIMUM OF 5/8 INCH UP TURN DAM AT THE INTERIOR EDGE. SILL FLASHING SHALL LAP UPSIDES OF OPENING A MINIMUM OF 2 INCHES AND OVER THE EXTERIOR FACE OF OPENING 2 INCHES -SIDES AND BOTTOM. I T I F T T TW YE F I I P P Y F U - 9 IT S RECOMMENDED HAT THIS S LL LASHING BE INS ALLED OVER HE O LA RS O BU LD NG A ER. ONE LA ER O N ADHESIVE FLEXIBLE FLASHING WITH A MINIMUM HEIGHT OF 9 INCHES TO BE APPLIED TO WALL BELOW FLASHING. ONE LAYER OF SELF ADHESIVE SHALL BE APPLIED TO WINDOW OPENING AND LAP DOWN WALL OVER FIRST LAYER OF FLEXIBLE FLASHING A MINIMUM OF 2 INCHES. I 0 ROOF TO WALL FLASHING: THE FLASHING MUST EXTEND UP THE WALL AND ONTO THE ROOF A MINIMUM OF 4 INCHES. NAIL THE FLASHING PIECES TO THE ROOF SHEATHING ABOVE THE TOP OF EACH SHINGLE COURSE. I I FLASHINGS ARE GENERALLY FORMED IN 10 FOOT SECTIONS. SECTIONS SHOULD BE LAPPED 8 INCHES MINIMUM IN THE DIRECTION OF FLOW. THE TOP OF EACH SECTION SHOULD BE FASTENED WITH NAILS OF MATERIAL COMPATIBLE WITH THE FLASHING. 12 ROOF VALLEY FLASHING: THE VALLEY FLASHING SHOWN ON DRAWINGS IS OF AN OPEN TYPE, WHERE SOME OF THE FLASHING 15 EXP05ED TO VIEW. THE OPEN PORTION OF THE VALLEY SHOULD BE A MINIMUM OF 5 INCHES AND THE SHINGLES SHOULD LAP THE FLASHING A MINIMUM OF 5 INCHES (fHE FLASHING SHOULD LAP EACH SECTION OF ROOF A MINIMUM OF I O INCHES). THE EDGES OF THE VALLEY FLASHING SHOULD BE FORMED WITH A HOOK EDGE AND CLEATED ON 24 INCH CENTERS. 13 ON ROOF PITCHES OVER 6: 12 AND ON DISSIMILAR PITCHES, INCREASE THE INVERTED VEE (`V" CRIMP) IN THE VALLEY TO 2 INCH HEIGHT. 14 FLASHINGS ARE GENERALLY FORMED IN 10 FOOT SECTIONS. SECTIONS SHOULD BE LAPPED 8 INCHES MINIMUM IN THE DIRECTION OF FLOW. THE TOP OF EACH SECTION SHOULD BE FASTENED WITH NAILS OF MATERIAL COMPATIBLE WITH THE FLASHING. A 30 INCH WIDE FELT IS PLACED IN THE VALLEY. 15 THE FELT IN THE VALLEY SHOULD LAP G INCHES OVER THE UPPER END OF THE VALLEY FLASHING PIECES. THE ROOFING FELT SHOULD LAP OVER THE CLEATED EDGES OF THE FLASHING. 16 COPPER (MINIMUM 160Z.), OR STAINLESS STEEL (MINIMUM OF O.OI 8 INCHES) IS RECOMMENDED FOR VALLEY FLASHINGS. WHERE THE EXPECTED LIFE OF THE ROOF IS LESS THAN 15 YEARS, PRE -FINISHED OR GALVANIZED STEEL (MINIMUM 24 GAGE MAY BE USED -GALVANIZED FLASHING MUST BE PRE -PAINTED.) 17 ROOF EDGE FLASHING: THE METHOD FOR GABLE AND RAKE END FLASHING FOR A SHINGLE ROOF IS AS FOLLOWS. FLASHING IS FORMED IN SECTIONS AND IS LAPPED IN THE DIRECTION OF FLOW. FLASHING EXTENDING 4 INCHES ON THE ROOF IS NAILED TO THE SHEATHING 18 INCHES ON CENTER. A HEM IN THE ROOF FLANGE IS RECOMMENDED FOR SHAKE AND TILE ROOFING. FLASHING EXTENDING A MINIMUM OF I-I/2 INCHES DOWN THE FACE OF FASCIA ENDING WITH A CONTINUOUS CLEATED OR HEMMED DRIP EDGE. FELT IS LAPPED OVER THE FLASHINGS IN THIS APPLICATION. 18 ROOF PENETRATION FLASHING: MANY APPROVED PRE -MANUFACTURED ROOF PENETRATION FLASHINGS ARE READILY AVAILABLE FOR A VARIETY OF ROOF PENETRATIONS. THESE SHALL BE USE FOR APPROVED LOCATIONS INTENDED BY THE MANUFACTURER AND INSTALLED PER SPECIFICATIONS PROVIDED BY THE MANUFACTURE. IF HOWEVERA CUSTOM FLASHING IS REQUIRED FORA ROOF PENETRATION THE FOLLOW SHALL APPLY. ASUITABLE /COMPATIBLE METAL SHALL BE USED. THE BASE FLANGE OF THE FLASHING SHALL EXTEND ONTO THE ROOF A MINIMUM OF 4 INCHES. ALL SEAMS AND JOINTS SHALL BE FULLY SOLDERED. THE FLASHING SHALL FORM A SHAPE THAT PREVENTS WATER INTRUSION -REFER TO S.M.A.C.N.A. STANDARDS. . " ► ■ �� ►� ■ _1�IL�7��� M 1501 . I OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS IN ACCORDANCE WITH SECTION M 1506.3. AiR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. EXCEPTION: WHOLE -HOUSE VENTILATION -TYPE ATTIC FANS THAT DISCHARGE INTO THE ATTIC SPACE OF DWELLING UNITS HAVING PRIVATE ATTICS SHALL BE PERMITTED. M 1506.3 EXHAUST OPENINGS. AIR EXHAUST OPENINGS SHALL TERMINATE NOT LESS THAN 3 FEET (914 MM) FROM PROPERTY LINES; 3 FEET (914 MM) FROM OPERABLE � NON -OPERABLE [MECHANICAL] OPENINGS INTO THE BUILDING � I O FEET (3048 MM) FROM MECHANICAL AIR INTAKES EXCEPT WHERE THE OPENING IS LOCATED 3 FEET (914 MM) ABOVE THE AIR INTAKE. [MECHANICAL] OPENINGS SHALL COMPLY WITH SECTIONS R303.5.2 AND R303.G M 1507. I GENERAL. LOCAL EXHAUST AND WHOLE HOUSE VENTILATION SYSTEMS AND EQUIPMENT SHALL BE DESIGNED IN ACCORDANCE WITH THIS SECTION M 1507.2 RECIRCULATION OF AIR. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT DISCHARGE INTO THE ATTIC, CRAWL SPACE AND OTHER AREAS INSIDE THE BUILDING. M 1507.3 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM. WHOLE -HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE DESIGNED INACCORDANCE WITH SECTIONS M 1507.3. I THROUGH M 1507.3.7.3 M 1507.3. 1 SYSTEM DESIGNS. EACH DWELLING UNIT OR GUEST ROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M 1507.3.4, M 1507.3.5, M 1507.3.G, M 1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M 1507.3.2 CONTROL AND OPERATION. I LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2 INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE 5Y5TEM. 3 LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, HUMIDISTAT, TIMERS, OR OTHER APPROVED MEANS 4 CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEM. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEM SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON� A5 OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEMS WITHOUT ENERGIZING OTHER ENERGY CONSUMING DEVICES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION(SEE OPERATING INSTRUCTIONS)." 5 INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: • 5. 1 . THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. • 5.2. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED AIR SYSTEM FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY- CONSUMING APPLIANCES. • 5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION M 1507.3.3 • 5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IC CAN OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. • 5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. • 5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. • 5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING • 5.8. A LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS). " • M 1507.3.2. I OPERATING INSTRUCTIONS. INSTALLERS SHALL PROVIDE THE MANUFACTURERS INSTALLATION, OPERATION INSTRUCTIONS, AND AWHOLE- HOUSE VENTILATION SYSTEM OPERATION DESCRIPTION M 1507.3.3 MECHANICAL VENTILATION RATE. THE WHOLE -HOUSE VENTILATION SYSTEM SHALL PROVIDE OUTDOOR AIR TO EACH HABITABLE SPACE AT A CONTINUOUS RATE AT A CONTINUOUS RATE OF NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH TABLE M 1507.3.3(I ). EXCEPTION: THE WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM IS PERMITTED TO OPERATE INTERMITTENTLY WHERE THE SYSTEM HAS CONTROLS THAT ENABLE OPERATION FOR NOT LESS THAN 25-PERCENT OF EACH 4-HOUR SEGMENT AND THE VENTILATION RATE PRESCRIBED IN TABLE M 1507.3.3(I) IS MULTIPLIED BY THE FACTOR DETERMINED IN ACCORDANCE WITH TABLE M ! 507.3.3(2). M 1507.3.4 WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTIONS SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR AWHOLE- HOUSE VENTILATION SYSTEM. M ! 507.3.4. 1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCH WATER GAUGE AS SPECIFIED IN TABLE M 1507.3.3(I ). MANUFACTURER'S FANS FAN FLOW RATINGS SHALL BE DETERMINED IN ACCORDANCE ACCORDING TO HVI 916 HOME VENTILATION INSTITUTE AIRFLOW TEST PROCEDURE OR AMCA 2 ! 0, LABORATORY METHODS OF TESTING FANS FOR CERTIFIED AERODYNAMIC PERFORMANCE RATING. M 1507.3.4.2 FAN NOISE. WHOLE -FANS LOCATED 4 FEET (I 219.2 MM) OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONS RATING OF I.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 HOME VENTILATION INSTITUTE LOUDNESS TESTING AND RATING PROCEDURE. REMOTELY - MOUNTED FANS SHALL BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM ATTACHED DUCTWORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M 1507.3.4.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENT SECTIONS M 1507.3.2 AND M 1 507.3.2. I M 1507.3.4.4 OUTDOOR AIR INLETS. OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOORAIRINLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF �/z INCH (91 2.7 MM) ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: I HAVE CONTROLLABLE AND SECURE OPENINGS; 2 BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3 PROVIDE NOT LESS THAN 4 SQUARE INCHES (2581 MM2) OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT I O PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES (258 ! MM2) OF NET FREE AREA. 4 INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OROTHER MATERIAL. 5 OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: /� ATELI E R PROJECT JONATHAN CASTILLO ADDRESS 7216 SOUNDVIEW DR EDMONDS, WA 98026 DATE 20-07-20 KA-N-02 G 3. I . CLOSER THAN 10 FEET (3048 MM) FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET (914.4 MM) ABOVE THE OUTDOOR AIR INLET. 7 3.2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 8 3.3. A HA7_ARDOUS OR UNSANITARY LOCATION 9 3.4. A ROOM OR SPACE HAVING ANY FUEL BURNING APPLIANCES THEREIN. I O 3.5. CLOSER THAN 10 FEET (3048 MM) FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET (91 4.4 MM) ABOVE THE AIR INLET. I I 3.G. ATTIC, CRAWL SPACES, OR GARAGES. 'i•� ' • I SECTION R806 SRC -ENCLOSED ATTICS AND RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF THE ROOF RAFTERS SHALL HAVE CROSS VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE CF RAIN OR SNOW. VENTILATING OPENINGS SHALL BE PROVIDED WITH CORROSION RESISTANT WIRE MESH, WITH I/8" (3.2MM) TO I/4" (6.4MM) OPENINGS. 2 THE TOTAL NET FREE VENTILATION AREA SHALL BE NOT LESS THAN I/I 50 OF THE AREA OF EACH SPACE TO BE VENTILATED, EXCEPT THAT THE AREA MAY BE I)300 PROVIDED THAT 50 TO 80 PERCENT OF THE REQUIRED VENTILATION AREA IS LOCATED IN THE UPPER PORTION AND AT LEAST 3 FEET ABOVE SAVE OR COMIC VENTS WITH THE BALANCE BEING PROVIDED SAVE OR CORNICE VENTS, OR IF A VAPOR RETARDER NOT EXCEEDING A I PERM RATING IS INSTALLED ON THE WARM SIDE OF THE INSULATION. SEE CALCULATIONS IN THE DRAWINGS. 3 AT LEAST 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. 4 UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY SAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. 5 EAVE BAFFLES: FOR AIR PERMEABLE INSULATIONS IN VENTED ATTICS, A BAFFLE SHALL BE INSTALLED ADJACENT TO SOFFIT AND EAVE VENTS. BAFFLES SHALL MAINTAIN AN OPENING EQUAL OR GREATER THAN THE SI7_E OF THE VENT. THE BAFFLE SHALL EXTEND OVER THE TOP OF THE ATTIC INSULATION. THE BAFFLE SHALL BE PERMITTED TO BE ANY SOLID MATERIAL. WSEC.R402.2.3 C WHERE VENTS OCCUR, BAFFLING OF THE VENT OPENING SHALL BE PROVIDED SO AS TO DEFLECT THE INCOMING AIR ABOVE THE SURFACE INSULATION. INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A ONE INCH (25.4) SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AT THE LOCATION OF THE VENT. ■ �11� � THERMAL INSULATION: (PRESCRIPTIVE OPTION III OF THE WSEC) WALLS (BELOW -GRADE, EXTERIOR): WALLS (BELOW -GRADE, INTERIOR): WALL (ABOVE -GRADE): HEADERS: CEILINGS (ADVANCED FRAMING): CEILINGS (STANDARD FRAMING): CEILINGS (VAULTED): FLOORS SLAB: SOLID DOORS: WINDOWS � DOORS W/GLAZING: OVERHEAD GLAZING: R-10 RIGID INSULATION R-2 I BATT OR RIGID INSULATION R-2 I GATT OR RIGID INSULATION R-10 RIGID INSULATION R-38 GATT R-49 GATT ICYNENE WITH R VALUE OF 3.6 PER INCH R-30 GATT OR RIGID INSULATION R-10 RIGID INSULATION 24" chi PERIMETER U-VALUE OF .20 OR BETTER U-VALUE OF .28 OR BETTER U-VALUE OF .50 OR BETTER I R-VALUES ARE MINIMUMS. U-FACTORS AND SHGC ARE MAXIMUMS. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE AI OI .4 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE. 2 THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS. THE SHGC COLUMN APPLIES TO ALL GLAZED FENESTRATION. EXCEPTION: SKYLIGHTS MAY BE EXCLUDED FROM GLAZED FENESTRATION SHGC REQUIREMENTS IN CLIMATE ZONES I THROUGH 3 WHERE THE SHGC FOR SUCH SKYLIGHTS DOES NOT EXCEED 0.30. 3 "10/15/21 .+TB" MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR OF THE WALL. OR R-15 ON THE CONTINUOUS INSULATION ON THE INTERIOR OF THE WALL, OR R-21 CAVITY INSULATION PLUS A THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL. 10/I 5/21 .+TB SHALL BE PERMITTED TO BE MET WITH R-I 3 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL. "10/13" MEANS R-10 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE HOME OR R-I 3 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL. "TB" MEANS THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT WALL. 4 R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON GRADE FLOORS. SEE R402.2.9. I . 5 THERE ARE NO SHGC REQUIREMENTS IN THE MARINE ZONE. 6 BASEMENT WALL INSULATION IS NOT REQUIRED IN WARM -HUMID LOCATIONS AS DEFINED BY FIGURE R301 .I AND TABLE R301.1. 7 RESERVED. 8 FIRST VALUE IS CAVITY INSULATION, SECOND IS CONTINUOUS INSULATION OR INSULATED SIDING, SO "I 3.+5" MEANS R-I 3 CAVITY INSULATION PLUS R-5 CONTINUOUS INSULATION OR INSULATED SIDING. IF STRUCTURAL SHEATHING COVERS 40 PERCENT OR LESS OF THE EXTERIOR, CONTINUOUS INSULATION R-VALUE SHALL BE PERMITTED TO BE REDUCED BY NO MORE THAN R-3 IN THE LOCATIONS WHERE STRUCTURAL SHEATHING IS USED TO MAINTAIN A CONSISTENT TOTAL SHEATHING THICKNESS. 9 THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIOR OF THE MASS WALL. I 0 FOR SINGLE RAFTER- ORJOIST-VAULTED CEILINGS. THE INSULATION MAY BE REDUCED TO R-38. I I INT. (INTERMEDIATE FRAMING) DENOTES STANDARD FRAMING 16 INCHES ON CENTER WITH HEADERS INSULATED WITH A MINIMUM CF R-10 INSULATION. 12 LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE THICKNESS OF 3.5 INCHES ARE EXEMPT FROM THIS INSULATION REQU I REM ENT. TABLE R402.4. I . I AIR BARRIER AND INSULATION •INSTALLATION COMPONENT CRITERIA (A) AIR BARRIER AND THERMAL BARRIER A •AIR BARRIER AND THERMAL BARRIER A CONTINUOUS AIR BARRIER SHALL BE INSTALLED IN THE BUILDING ENVELOPE. EXTERIOR THERM AL ENVELOPE CONTAINS A CONTINUOUS AIR BARRIER. BREAKS OR JOINTS IN THE AIR BARRIER SHALL BE SEALED. AIR PERMEABLE INSULATION SHALL NOT BE USED AS A SEALING MATERIAL. CAVITY INSULATION •CAVITY INSULATION INSTALLATION ALL CAVITIES IN THE THERMAL ENVELOPE SHALL BE FILLED WITH INSULATION. THE DENSITY OF THE INSULATION SHALL BE AT THE MANUFACTURERS' PRODUCT RECOMMENDATION AND SAID DENSITY SHALL BE MAINTAINED FOR ALL VOLUME OF EACH CAVITY. BATT TYPE INSULATION WILL SHOW NO VOIDS OR GAPS AND MAINTAIN AN EVEN DENSITY FOR THE ENTIRE CAVITY. BATT INSULATION SHALL BE INSTALLED IN THE RECOMMENDED CAVITY DEi�H. WHERE AN OBSTRUCTION IN THE CAVITY DUE TO SERVICES, BLOCKING, BRACING OR OTHER OBSTRUCTION EXISTS; THE BATT PRODUCT WILL BE CUT TO FIT THE REMAINING DEPTH OF THE CAVITY. WHERE THE BATT IS CUT AROUND OBSTRUCTIONS, LOOSE FILL INSULATION SHALL BE PLACED TO FILL ANY SURFACE OR CONCEALED VOIDS, AND AT THE MANUFACTURERS' SPECIFIED DENSITY. WHERE FACED BATT IS USED, THE INSTALLATION TABS MUST BE STAPLED TO THE FACE OF THE STUD. THERE SHALL BE NO COMPRESSION TO THE BATT AT THE EDGES OF THE CAVITY DUE TO INSET STAPLING INSTALLATION TABS.INSULATION THAT UPON INSTALLATION READILY CONFORMS TO AVAILABLE SPACE SHALL BE INSTALLED FILLING THE ENTIRE CAVITY AND WITHIN THE MANUFACTURERS' DENSITY RECOMMENDATION. CEILING/ATTIC •CEILING/ATTIC THE AIR BARRIER IN ANY DROPPED CEILING/SOFFIT SHALL BE ALIGNED WITH THE INSULATION AND ANY GAPS IN THE AIR BARRIER SEALED. ACCESS OPENINGS, DROP DOWN STAIR OR KNEE WALL DOORS TO UNCONDITIONED ATTIC SPACES SHALL BE SEALED. BATT INSULATION INSTALLED IN ATTIC ROOF ASSEMBLIES MAY BE COMPRESSED AT EXTERIOR WALL LINES TO ALLOW FOR REQUIRED ATTIC VENTILATION. WALLS •WALLS CORNERS AND HEADERS SHALL BE INSULATED AND THE JUNCTION OF THE FOUNDATION AND SILL PLATE SHALL BE SEALED. THE JUNCTION OF THE TOP PLATE AND TOP OF EXTERIOR WALLS SHALL BE SEALED. EXTERIOR THERMAL ENVELOPE INSULATION FOR FRAMED WALLS SHALL BE INSTALLED IN SUBSTANTIAL CONTACT AND CONTINUOUS ALIGNMENT WITH THE AIR BARRIER. KNEE WALLS SHALL BE SEALED. WINDOWS, SKYLIGHTS AND DOORS WINDOWS, SKYLIGHTS AND DOORS THE SPACE BETWEEN WINDOW/DOOR JAMBS AND FRAMING AND SKYLIGHTS AND FRAMING SHALL BE SEALED. RIM JOISTS I •RIM JOISTS RIM JOISTS SHALL BE INSULATED AND INCLUDE THE AIR BARRIER. FLOORS (INCLUDING ABOVE -GARAGE AND INSULATION SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT WITH CANTILEVERED FLOORS) UNDERSIDE OF SUBFLOOR DECKING. THE AIR BARRIER SHALL BE INSTALLED AT ANY EXPOSED EDGE OF INSULATION. CRAWL SPACE WALLS CRAWL SPACE WALLS WHERE PROVIDED IN LIEU OF FLOOR INSULATION, INSULATION SHALL BE PERMANENTLY ATTACHED TO THE CRAWLSPACE WALLS. EXPOSED EARTH IN UN VENTED CRAWL SPACES SHALL BE COVERED WITH A CLASS I VAPOR RETARDER WITH OVERLAPPING JOINTS TAPED. SHAFTS, PENETRATIONS SHAFTS, PENETRATIONS DUCT SHAFTS, UTILITY PENETRATIONS, AND FLUE SHAFTS OPENING TO EXTERIOR OR UNCONDITIONED SPACE SHALL BE SEALED. NARROW CAVITIES NARROW CAVITIES BATTS IN NARROW CAVITIES SHALL BE CUT TO FIT AND INSTALLED TO THE CORRECT DENSITY WITHOUT ANY VOIDS OR GAPS OR COMPRESSION. NARROW CAVITIES SHALL BE FILLED BY INSULATION THAT ON INSTALLATION READILY CONFORMS TO THE AVAILABLE CAVITY SPACE GARAGE SEPARATION •GARAGE SEPARATION AIR SEALING SHALL BE PROVIDED BETWEEN THE GARAGE AND CONDITIONED SPACES. RECESSED LIGHTING RECESSED LIGHTING RECESSED LIGHT FIXTURES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE AIR TIGHT, IC RATED, AND SEALED TO THE DRYWALL. PLUMBING AND WIRING PLUMBING AND WIRING BATT INSULATION SHALL BE CUT NEATLY TO FIT AROUND WIRING AND PLUMBING IN EXTERIOR WALLS. THERE SHALL BE NO VOIDS OR GAPS OR COMPRESSION WHERE CUT TO FIT. INSULATION THAT ON INSTALLATION READILY CONFORMS TO AVAILABLE SPACE SHALL EXTEND BEHIND PIPING AND WIRING. SHOWER�I"UB SHOWER,(fUB ON EXTERIOR WALL EXTERIOR WALLS ADJACENT TO SHOWERS AND TUBS SHALL BE INSULATED AND THE AIR BARRIER INSTALLED SEPARATING THEM FROM THE SHOWERS AND TUBS. ELECTRICAUPHONE BOX ON EXTERIOR WALLS ELECTRICAUPHONE BOX ON EXTERIOR WALLS THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL OR COMMUNICATION BOXES OR AIR SEALED BOXES SHALL BE INSTALLED. HVAC REGISTER BOOTS •HVAC REGISTER BOOTS HVAC REGISTER BOOTS THAT PENETRATE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO THE SUBFLOOR OR DRYWALL. FIREPLACE FIREPLACE AN AIR BARRIER SHALL BE INSTALLED ON FIREPLACE WALLS. ....FIREPLACES SHALL HAVE GASKETED DOORS U.L. APPROVED APPLIANCES INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, UPC, � IMC. AUTO SHUTOFF SWITCH REQUIRED FOR GAS OR PROPANE. INSTALL WATER HEATER ON A GALVANIZED STEEL PAN WITH DRAIN PER UPC. SET ELECTRIC WATER HEATER ON R-10 INCOMPRESSIBLE INSULATED BASE IF INSTALLED IN AN UNHEATED AREA OR ON A CONCRETE SLAB. INSTALL SEISMIC STRAPS WITHIN TOP I /3 AND BOTTOM I/3 (4" MINIMUM ABOVE CONTROLS). PROVIDE PRESSURE RELIEF LINE TO EXTERIOR. FOR FUEL FIRED APPLIANCES, PROVIDE 2 SCREENED COMBUSTION INLETS, ONE WITHIN 12" OF CEILING � ONE WITHIN 12" OF FLOOR, WITH A MINIMUM NET FREE AREA OF I SQ. IN. PER 4,000 BTU/H OF TOTAL INPUT RATING OF ALL APPLIANCES IN THE ENCLOSURE. INSTALL FUEL -FIRED APPLIANCES IN SEALED ENCLOSURE WITH A WEATHERSTRIPPED SOLID SELF -CLOSING DOOR. ENCLOSURE NOT TO BE USED FOR OTHER PURPOSES. M 130�.2 I ANCHORAGE AND STRAPPING SHALL BE DESIGN TO RESIST A HORIZONTAL FORCE EQUAL TO ONE-THIRD OF THE OPERATING WEIGHT OF THE WATER HEARET STORAGE TANK, ACTING IN ANY HORIZONTAL DIRECTION. STRAPPING SHALL BE AT POINT WITHIN THE UPPER ONE-THIRD AND LOVER ONE-THIRD OF THE APPLIANCE'S VERTICAL DIMENSIONS. AT THE LOWER POINT, THE STRAPPING SHALL MAINTAIN A MINIMUM DISTANCE OF 4 INCHES (I 02MM) ABOVE THE CONTROLS. 2 THE ANCHORAGE STRAPPING SHALL BE IN ACCORDANCE WITH THE APPLIANCE MANUFACTURER'S RECOMMENDATIONS. ADU NOTES 20.21 .030 CRITERIA FOR ATTACt1ED ACCESSORY DWELLING UNITS. NUMBER OF UNITS. ASINGLE-FAMILY DWELLING MAY HAVE NO MORE THAN ONE ACCESSORY DWELLING UNIT PER LOT. I SIZE. IN NO CASE SHALL AN ACCESSORY DWELLING UNIT BE (I) LARGER THAN 40 PERCENT OF THE LIVABLE FLOOR AREA OF THE PRINCIPAL DWELLING, (2) NOR MORE THAN 800 SQUARE FEET, (3) NOR HAVE MORE THAN TWO BEDROOMS; PROVIDED, IF THE ACCESSORY DWELLING UNIT IS COMPLETELY LOCATED ON A SINGLE FLOOR, THE PLANNING MANAGER MAY ALLOW INCREASED S17_E UP TO 50 PERCENT OF THE FLOOR AREA OF THE PRINCIPAL DWELLING IN ORDER TO EFFICIENTLY USE ALL FLOOR AREA, SO LONG AS ALL OTHERSTANDARDS SET FORTH IN THIS CHAPTER ARE MET. 2 LOCATION AND APPEARANCE. THE SINGLE-FAMILY APPEARANCE AND CHARACTER OF THE RESIDENCE SHALL BE MAINTAINED WHEN VIEWED FROM THE SURROUNDING NEIGHBORHOOD. THE DESIGN OF THE ACCESSORY DWELLING UNIT SHALL BE INCORPORATED INTO THE DESIGN OF THE PRINCIPAL DWELLING UNIT AND SHALL BE DESIGNED TO MAINTAIN THE ARCHITECTURAL DESIGN, STYLE, APPEARANCE AND CHARACTER OF THE MAIN BUILDING AS ASINGLE-FAMILY RESIDENCE USING MATCHING MATERIALS, COLORS, WINDOW STYLE, AND ROOF DESIGN. THE PRIMARY ENTRANCE TO THE ACCESSORY DWELLING UNIT SHALL BE LOCATED IN SUCH A MANNER AS TO BE UNOBTRUSIVE WHEN VIEWED FROM THE STREET. WHENEVER POSSIBLE, NEW ENTRANCES SHOULD BE PLACED AT THE SIDE OR REAR OF THE BUILDING. ONLY ONE ELECTRIC AND ONE WATER METER SHALL BE ALLOWED FOR THE ENTIRE BUILDING, SERVING BOTH THE PRIMARY RESIDENCE AND THE ACCESSORY DWELLING UNIT. ACCESSORY DWELLING UNITS MUST BE LOCATED WITHIN OR ATTACHED TO SINGLE-FAMILY DWELLING UNITS. 3 PARKING. ONE OFF-STREET PARKING SPACE IN ADDITION TO THE PARKING SPACES NORMALLY REQUIRED FOR THE PRINCIPAL DWELLING SHALL BE REQUIRED TO BE PROVIDED FOR THE ACCESSORY DWELLING UNIT, BUT IN NO EVENT LESS THAN THREE SPACES PER LOT. 4 SAFETY, LIGHT, VENTILATION, FLOOR AREA AND SIMILAR FACTORS. ACCESSORY DWELLING UNITS SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF THE UNIFORM HOUSING CODE AND THE UNIFORM BUILDING CODE ADOPTED BY ECDC TITLE 19 AND SHALL COMPLY IN ALL RESPECTS WITH THE PROVISIONS OF THE EDMONDS COMMUNITY DEVELOPMENT CODE. NO PERMIT FOR AN ACCESSORY DWELLING UNIT SHALL BE ISSUED TO A NONCONFORMING STRUCTURE UNLESS THAT STRUCTURE IS BROUGHT INTO CONFORMANCE WITH THE THEN CURRENT PROVISIONS OF THIS CODE. 16.20.050 SITE DEVELOPMENT STANDARDS -ACCESSORY BUILDINGS. GARAGES OR OTHER ACCESSORY BUILDINGS ATTACHED BY A BREEZEWAY., HALLWAY, OR OTHER SIMILAR CONNECTION TO THE MAIN BUILDING WHICH RESULTS IN A SEPARATION EXCEEDING 10 FEET IN LENGTH MAY NOT EXCEED THE 15-FOOT HEIGHT LIMIT. THE SEPARATION SHALL BE DETERMINED BY THE MINIMUM DISTANCE BETWEEN THE OUTSIDE WALLS OF THE MAIN BUILDING AND ACCESSORY BUILDING, EXCLUSIVE OF THE CONNECTING STRUCTURE. /� ATELI E R PROJECT JONATHAN CASTILLO ADDRESS 7216 SOUNDVIEW DR EDMONDS, WA 98026 DATE 20-07-20 KA-N-03 N3 SH EARINALL SCHEDULE Notes apply as called out in table below. 1 Anchor bolts embedded at least 7", ar expansion anchors embedded at least 4". See detail SWB. 2 �MASAP can be installed instead of sill bolts with washers. When replacing'Iz"f� sill bolt use 7-10dx1'Ia" nails (minimum nailing} and when replacing s/a"0 sill bolts use 9-lddxi'/z" nails (maximum nailing}. 4 See detail SWR Letter designations a & b refer to specific conditions. For gable -end roof connections see detail SWF 5 See detail SWB SHEAR FLOW CaNNECTIaNS � SPACING S 5IL1.-TD _ FLOOR-TD- ROOF -TO - WALL BASE PLATE CALL FOUNDATION 1, Z SILL &WALL WALL 4 5 ❑UT 5/8"0 @ 60"ac ar �Hi @ 16d @ 10"oc A �12"0 60"oc 24"oc 4a 5/8"0 @ 60"ac ar _ �LS5fl @ 15d @ 6"4C �/2 "!� @ 40"ac 36"oc 4b HOEDOWN SCHEDULE WALL SHEATHING CALL OUT SHEATHING THICKNESS EDGE NAILS 5 7116" 8d @ 6"ac 1 Deepen the foundation as needed to provide the required holdown embedment into the foundation wall. See Detail MHE 2 Fasten to the end framing members of the shearwall, u.n.o. 3 FOUNDATION ANCHOR may be extended with threaded rod and coupler as required. 4 Provide the minimum embedment and edge distances specified by the manufacturer. 5 Attach to (2} 2x studs minimum (lamination connection same as WALL BASE PLATE; stagger nails], u.n.o. 6 See detail HDN for insta Ilation. HOEDOWN 1 STRAP FOUNDATION 1, 2, 4, 6 FASTENERS 5 ANCHOR 1, 3, 4, 6 COMMENTS *HTT5 26-10d s1a"O T.R. 8" min embed with SET epoxy in 6" min thick fdn wall CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or other codes required by the governing jurisdiction. BUILD�IG ENVELOPE Through maintenance and current best practices, provide a building envelope that will preserve the integrity of the structure throughout it's lifetime. Any reference to envelope related materials or methodology shall not be interpreted as a specification by this office. �T6PECTIONS Notify Building Department for inspections required by local jurisdiction. SOAS Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed level soil devoid of any organic material and below indicated frost line. COMPACTED FILL shall consist of predominately Well -Graded, granular soil, free of organic material and debris. Fill should be placed in maximum 8" loose lifts and compacted to a minimum of 95 percent of the maximum density at optimum moisture content determined by ASTM D-1557 test procedures. BACIQILL shall be free draining and without organic material and debris from one of the following soil classes SM-SC, SM, SP, SW, GC, GM, GP, and GW. FOUNDATIONS AND RETAINLNG WALLS Extend footings to undisturbed bearing soil. Do not backfill until all slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement. There shall be no machine compaction on the retaining side of the structure for a distance equivalent to 2/3rds the wall height. SAL PLATES Use pressure treated 2x plates u.n.o. Embed anchor bolts at least 7" (expansion anchors 4"). Use 3"x3"x0.229" washers. There shall be a minimum of two bolts per piece spaced not more than 6 feet apart, with one bolt located not more than 12" or less than 4" from each end of each piece. CONCRErE f c = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum of 6 gallons of water per 94 Ib sack of cement. Maximum slump is 4". Segregation of materials shall be prevented through proper handling and placement. REIf�fORC�VG STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices. CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o. See applicable detail(s): RI FOOT!!VG DRAINAGE Footing drainage per Building Code section 1805.4.2 &Residential Code section R405.1. WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated. Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations. COMECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate preservative treated wood in an interior, dry environment shall be permitted. SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to ��WWPA GRADING RULES FOR WESTERN LUMBER", latest edition: BEAMS, POSTS, RAFTERS, ]GIST 4X DF#2 2x 8 and smaller HF#2 WALL STUDS 2x HF#2 TRUSSES Manufactured trusses are a deferred submittal item designed per CODE section 2303.4 and shall be designed for all loads and load combinations per the CODE. All connections per manufacturer, u.n.o. If truss layout is changed by manufacturer, please notify this office. See applicable detail(s): GEB OVER -FRAMING Unless noted otherwise by truss manufacturer, overframe with 2x4 rafters @ 24" oc. Post down w/ 2x4 @ 48" oc, staggered. Brace posts over 6'-0" tall perpendicular to wide face. WALL FRAMAVG &BEARING Walls shall be 2x studs at 16"oc max with double 2x top plate, and 2x base plate (exterior walls shall be 2x6 u.n.o. &interior walls shall be 2x4 u.n.o.). Block all supports solid to the foundation. See applicable detail(s): BHS TPS BEAM PENETRATIONS Allowable beam penetrations shall be made in the middle third of the span and the middle third of the depth. Contact this office for any penetration outside the allowable area. See applicable detail(s): BP POF WOOD SHRINKAGE All plumbing including water, gas, waste, and roof drainage shall be installed with shrinkage is considered to be 3/8" to 1/2" per story. Joints are to be clearly shown on shop drawings and are to be submitted to the architect engineer for review prior to construction. GENERAL STRUCTURAL NOTES continued WOOD STRUCTtR2AL PANELS shall meet the performance standards of the "APA" DOC PS1 and PS2 for their intended application (group 5 species not allowed). SHEARWALL.S are indicated on the plans with a bold dashed line and labeled SW. The following letter designation refers to the Shearwall Schedule's SHEAR FLOW CONNECTIONS /SPACING table, and the number designation refers to the WALL SHEATHING table. Multiple combinations of letter and number designations may be present. Wall Line numbers, shown inside triangles, refer to corresponding engineering calculations. Attach rated sheathing (indicated below) to 2x min STUDS spaced no more than 16"oc, u.n.o. See Shearwall Schedule for minimum thickness and fasteners (thickness at point of fastened edges governs shear values). All panel edges shall be blocked. Nail intermediate supports @ 12"oc. Do not penetrate nails past flush. Install squash blocks under the ends of all shearwalls where the framing below does not provide full bearing. Construct cripple walls same as the shearwall above, and gable -ends same as the shearwall below. Rated sheathing: 7/16" OSB rated with a 24/16 span rating. 1/2" CD with a 32/16 span rating. See applicable detail(s): SWE ROOF DIAPHRAGM Install either OSB or CD sheathing: 7/16" OSB rated sheathing with a 24/16 span rating; panel clips required when spacing is greater than 20" oc. 1/2" CD rated sheathing with a 32/16 span rating. Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Nail all boundaries and supported edges with 8d @ 6"oc and interior supports with 8d @ 12"oc, blocking not required u.n.o. COMECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol,'��", indicates a hardware connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an equivilent or greater capacity selection. Install per the manufacturer instructions. Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification for Wood Construction (NOS) u.n.o. BOLTS All bolts and lag screws bearing in wood members shall conform to ASTM A307. Washers shall be installed under heads and nuts of all bolts or lag screws. HOEDOWNS See the HOEDOWN SCHEDULE. See applicable detail(s): HDN HOC RENDVATIONAND REMODEL Initial investigation limited to visual observations without desctructive removal of finishes. Consistant framing is assumed throughout the structure. Field verification is necessary during demolition. Contact this office should there be any variations from these assumptions. IXISTING CONDTIONS Structural members and assemblies shall be as specified on plans. Existing construction is adequate where it matches the material grades and specifications indicated. Where existing conditions or proposed construction differs either construct as shown on plans or contact this office to discuss options. DEMOLITION Limit construction loading and demolition debris on existing floor systems to not exceed existing capacity. As required, contractor shall provide temporary bracing until all permanent connections and stiffenings have been installed. DRY ROT Contactor shall check for and remove and repair any dry rotted member. Damaged members shall be repaired or replaced with alike -for -like substitution unless directed otherwise by this office. IOBSIfE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design and/or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their employees, or for access, visits, use work, travel, or occupancy by any person. OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound Structural Solutions Inc. MISCELLANEOUS Contractor shall verify all dimensions and existing site and building conditions prior to commencing any work. Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations. Basic Wind Speed (3 sec gust} mph 110 Surface Roughness B Wind Exposure Category B PLAN INSTRUCTIONS READ THIS FIRST These plans are organized so that more detailed or specific information is found in the same way by following the direction shown below: GENERAL STRUCTURAL NOTES SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more specific information. SCHEDULES DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more specific information. DETAILS PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for mare specific information. PLANS See the SYMBOL LEGEI� as well as AIBREVL4TTONS AND ACRONYMS far other additional information used on the PLANS. The term, TYPICAL (ar TYP}, used with a detail callout ar plan note, indicates that the information specified shall apply in all similar conditions. IF YnU HA IIE ANY QCIESTInNS DR CONCERNS CDNTA CT CIS IM1+9EDlA TEL Y.� VVe can be reached immediately by phone: [4Z5) 778-10�3 For less pressing questions, email us: inbox@ssseng.00m Please help us get tQ your plans by having this job number handy: s20�4D17 ABBREVIATIONS AND ACRONYMS ABV ABOVE E.S. EACH SIDE O.C. ON CENTER A.B. ANCHOR BOLT E.W. ERCH WAY P.T. PRESSURE TREATED BLW BELOW EA 1=ACH REINF REINFORCEMENT BL.K BLOCK E.N. EDGE NAILDVG READ REQUIRED BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE B.N. BOUNDARY NAILING IXLST IXLSTING 5iM SIMIt.AR BTM BOTTOM FDN FOUNDATION STD STANDiRRD BRG BEARING FLR FLOOR STRUCT STRUCTURAL BTWN BETWEEN FRMG FRAMING 5W SHEARWALL CLR CLEAR FTG FOOTING THRU THROUGH CLTR COt[J=CTOR G.T. GIRDER TRUSS TYP TYPICAL CONC CONCRETE GR GRADE U.N.O. UNLESS NOTED CONN CONNECTION FiORI1 I-iDRI�ONTAL # OTHERWISE CONT CONTINUOUS MAX MAXIMUM VERT VERTICAL CTR CENTER MFG MANUFACTURED w/ WITH DBE. DOUBLE MIN MINIMUM w/a WITHOUT DET DETAIL o/ OVER W.W.F. WELDED WIRE FABRIC E.E. EACH END oc ON CENTER DESIGN CRITERIA Governing Dade 15 IBC Risk Category II Wind Design Data Earthquake Design Data Grar►ity Load Data Raafs: loads are psf dead Live Snow Trusses (pitched} ■Pitches =_ 8:12 Top Chard 10 0 20 Bottom Chord 5 0 0 Sail Data Allowable Soil Bearin 2000 sf Seismic Importance Factor, Ie 1.00 Site Classification D Short Period Acceleration, SS 1.302 1-Second Acceleration S1 0.511 Seismic Design Category p Spectral Response Coefficient, Sps 0.868 Spectral Response Coefficient, 501 0.511 Internal Pressure Coefficient +J- 0.18 Topographic Factor, KZF 1.fJ0 Wind Importance Factor, I 1.D0 Seismic Farce Resisting System Table 12.2-i: A-i5 2010 Equiv. Lateral Force Procedure Response Modification Factor, R 6.5 5.5 Transverse Longitudinal Seismic Response Coefficient, CS 0.134 0.134 Transverse Longitudinal Seismic Base Shear, V 1643 Ibs 555 Number: 52Q�t� 1 Project Narne: 7215 5ound►►iew Dr Owner: ]vnathan Castillo Project Location: 7216 5aund►►iew Dr Edmvnds� WA 98�Z6 Design Professional: ICatelier This space reserved for governing jurisdiction stamps ORIGIN DATE: 6/3/2020 REVISED: ---- 0 0 0 N cn I c ca s� cl') (!) C/] I N LI"] O O N 555 Number: 4�6 �LS50 @SHEARWALLS 524fl4017 HTTS ROOF DIAPHRAGM PER STRUCT NOTES PER SCHED Z�„ ���1 Project Name: EDGE NAILS ��SS�O�� 7215 5ound►►iew Dr SOLID *H2,5A #H1 @ Clwner: SHEARWALLS #H2.5A @ALL BLKG MIN @ALL ROOF ]vnathan Castillo HTT5- A ROOF MEMBERS WALL MEMBERS U.N.O. @ HDN HOEDOWNS SHEARWALLS a b Project Location: SHEARWALL w/ TRUSS OR RAFTER BEARING 7216 5aund►►iew Dr N.T.s. HDNA — — Edmunds, WA 980Z6 BOUNDARY NAILS SHEATHING PER SWR SHEARWALL ROOF CONNECTIONS Design Professional: PER NOTES NOTES STUDS PER N.T.S. CWn A ICatelier HOEDOWN SCHED SW SHEATHING J R/1 30° MIN EDGE NAILING 2x FLAT BLK w/ 2x STUD DBL ROW OF DIAPHRAGM PER NAILS PER BOUNDARY NAILS STRUCT NOTES SW SCHED WALL BASE � PLATE CONN TRUSS FLR RIM/BLKG HOEDOWN (OR ROOF GABLE) SOLID BLKG OR 2x4 BRACE @ 48"oc w/ 2x STUD ANCHOR M COLLECTOR �/-� [V #A35 AT BTM Z � O EDGE NAILS � ' �A35 PER GEB GABLE -END TRUSS BRACE PROVIDE SW SCHED J � � N.T.s. GEBA HOC HOEDOWN AT CORNER w/ OIS --WALL DOUBLE -SIDED SHEARWALLS, a � "' PARALLEL � N.T.S. HOCA INTERIOR SHEARWALLS, & J `� ... EXTERIOR SHEARWALLS EXT SHEARWALLS @CANTILEVERS � z � ROOF DIAPHRAGM SWF SHEARWALL FLOOR CONNECTIONS `J N V � � BEAM & #CS16 � � � w/ (16)1od REQUIRED STUDS N.T.S. SWFA AS SHOWN BEAM 2x4 WALL 2x6 WALL � z � FOR PSL &ESL, HOLES MUST BE ROUND AND ARE LIMITED TO 2" DIA, UNLESS APPROVED BY THE ENGINEER 4x & 2-2x (SAWN) DO NOT MAKE PENETRATIONS OR NOTCHES EXISTING 3%x (GEB) (2) 2x4 (2) 2x6 O � MINIMUM SPACING ROOF TRUSS 3%x (MANE) WALL IN THE SHADED AREA OF THE BEAM WITHOUT SHALL BE 2x THE PENETRATIONS IN THIS AREA DO NOT WALL BASE 6x & 3-2x (SAWN) PLATE CONN PRIOR APPROVAL OF THE ENGINEER DIAMETER OF THE REQUIRE APPROVAL FROM THE ENGINEER WALL 5%x (GEB) (3) 2x4 (3) 2x6 PER SW SCHED DIAPHRAGM PER LARGER HOLE 5%x(MANF) ANCH PER STRUCT NOTES �V SW SCHED 8x (SAWN) RIM/BLKG ANCH PER � %DEPTH 6 4x (GEB) (4) 2x4 (4) 2x6 SW SCHED � REQD 7x (MANE) 2x SILL U,N.O, � STUDS PER SW SCHED EDGE NAILS 2x SILL U.N,O, � 1 GIRDER TRUSS (3) 2x4 (3) 2x6 PER SW SCHED DEPTH /DEPTH O FDN FDN X FIRE BLOCK AT 10-FT REQUIRED TRIMMERS � %DEPTH 2x4 LEDGER •— SEEARCHITECTURAL KING HEADER 2x4 WALL 2x6 WALL SHEARWALLS TO FOUNDATION SHEARWALLS TO FLOOR TO FOUNDATION DRAWING FOR ASSEMBLY STUD HEADER 4x & 2-2x (SAWN) BALLOON FRAMED 3%x(GLB) zx4 zx6 SWB SHEARWALL BASE PLATE &FOUNDATION CONNECTIONS %SPAN %SPAN %SPAN WALL 3%x (MANE) �t4 V I�, 6x & 3-2x (SAWN) N.T.S. SWBA �°�w °� � �� SPAN � � 5/x (GEB) ---- (2) 2x6 REQD TRIMMERS 5%x (MANE) � a BP BEAM PENETRATIONS TYPICAL DETAIL BFW BALLOON FRAMED WALL NOTE: BEAR BEAMS ON THE FULL WIDTH AND BREADTH OF THE MINIMUM EXTENT OF EXTENT OF � ti� � SUPPORTS PER TABLES ABOVE UNLESS NOTED OTHERWISE ON THE PLANS SHEARWALL SHEARWALL TPS SWF SWR a � ao�zi ��° ti N.T.S. BPAA N.T.S. CRIPPLE STUD DOUBLE TOP PLATE ���� ���x�L ����� BHS BEAM &HEADER SUPPORTS � � N.T.S. This space reserved for HEADER HEADER governing jurisdiction stamps *PSPN516 w/ SHEARWALL I BOTTOM PLATE 8-16d NAILS INTO � #PSPN516 w/ FLOOR SHEATHING TOP PLATE, E.S. #PSPN58 w i BOTTOM PLATE (8)16d EVENLY SPACED, WINDOW 16d @ 16" oc OPENING / FLOOR SHEATHING 8-16d NAILS INTO #pSPN58 w/ TYP U,N.O, TYP FACE NAILS BEAM 1-8d NAIL INTO � TOP PLATE, E.S. #PSPN58 PLUMBING BASE PLATE, E.S. 1-8d NAIL INTO DISCONTINUOUS �CS16 w/, #PSPN58 PLUMBING BASE PLATE, E.S. DBL TOP PLATE DOOR PLUMBING SHEARWALL SHEARWALL � (13) 8d NAILS EA END ENI PLUMBING FLOOR O #PSPN516 1 Z' MIN 1 Z' MIN �LOOR O O � POST � KING STUD NOTCH AS � #PSPN516 I MIN 2x REQUIRED NOTCH AS TRIMMER STUD I REQUIRED � DBL TOP PLATE WALL STUD, TYP WALL STUD, DBL TOP PLATE WALL STUD, TYP WALL STUD, ELEVATION VIEW TOP PLATE NOTCH BOTTOM PLATE NOTCHp TYP � 4sPLICEN � PLAN VIEW PLAN VIEW ELEVATION VIEW TOP PLATE NOTCH BOTTOM PLATE NOTCH PLAN VIEW PLAN VIEW TOP PLATE SPLICE DISCONTINUOUS DBL TOP PLATE SWB SWF 4" x 4" IS THE MAXIMUM PENETRATION CRIPPLE STUD BASE PLATE � ORIGIN DATE: 6/3/2020 SHEARWALL EXTERIOR WALL OR HOLE THAT CAN BE ADDED TO A SHEARWALL REVISED: ---- POE PENETRATION OF FRAMING TPS DOUBLE TOP PLATE SPLICE SWE SHEARWALL ELEVATION 0 0 N.T.S. N.T.S. TPSA N.T.S. DRDDD �� 0 0 N EXISTING FDN NEW FDN (2) #4x16" BARS 4" EPDXY EMBED � •. e� � a • . NEW FDN IS CUT AWAY HERETO HELP ILLUSTRATE THE CONN OF .• THE NEW REINF TO THE EXISTING FDN a. NEF NEW TO EXISTING FOUNDATION N.T.S. #4 CONT wlin TOP 12" � OF WALL MIN FINISH GR / //�� 18° �i '' MIN 3" CLR �- BRG CONC FTG SOIL AND REINF NEFB SLAB NOTE: DEEPEN FOUNDATION AS REQUIRED TO ACCOMODATE FOR HOEDOWN EMBEDMENTS TEF THICKEN EDGE FOOTING N.T.s. TEFA TEF � � i i NOTES; -HTTS holdown -(26) lOd nails-5/8"diameter threaded rod (A307) -8" embed into the concrete, u.n.o. -Simpson AT-XP epoxy -Follow the manufacturers'specificationsfnr installing the anchor and hardware httn,llwww.stronatie.comloroductslanchorsystemsladhesivesladhesive anchoring install.html# se � ds {min.{ an I4 cycles (�In' sec�nds (min.) aQ psl min. psl min. EPX EPDXY - HTTS RETROFIT N.T.s. EXPB 4 SLAB ON GRADE wl 6x6 W1.4 x W1,4 12 WIDTH, TEF W W F TYP FOUNDATION PLAN SYMBOL LEGEND SLEXP �HOLDOWN MODEL HOEDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are wall-to-wall or wall -to fdn u.n.o. Connections per the HOEDOWN SCHEDULE. 1/4" = 1'-O" DO NOT SCALE -VERIFY ALL DIMENSIONS WITH ARCHITECTURAL SHEETS PRIOR TO CONSTRUCTION 555 Number: s2aa40i7 Project Narrre: 7215 50und►►iew Dr Owner: ]vnathan Castillo Project Location: 7216 50und►►iew Dr Edmvnds� WA 98�Z6 Design Professional: ICatelier This space reserved for governing jurisdiction stamps ORIGIN DATE: 6/3/2020 REVISED: ---- 0 0 0 N cn I c ca s� cl') (!) C/] I N LI"] O O N ��N SYMBOL LEGEND SLEXP DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like. SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections per the SHEARWALL SCHEDULE. #HOEDOWN MODEL HOEDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are wall-to-wall or wall -to fdn u.n.o. Connections per the HOEDOWN SCHEDULE. BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 (or 4x6) U.N.O. on the plan. JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max spacing between members will be indicated in bold type with a symbol which is representative of the layout of the entire level. WALL WALL WALL LINE LINE LINE A B C 1st FLOOR SHEARWALLS &FRAMING ABOVE 555 Number: s2aa40i7 Project Narrre: 7215 50und►►iew Dr Owner: ]vnathan Castillo Project Location: 7216 50und►►iew Dr Edmvnds� WA 98�Z6 Design Professional: ICatelier This space reserved for governing jurisdiction stamps ORIGIN DATE: 6/3/2020 REVISED: ---- 0 0 0 N cn I c ca s� cl') (!) C/] I N LI"] O O N