FIR2020-0073+Fire_Sprinkler_Equipment_Specification_Sheets+8.4.2020_1.24.17_PMBulletin 006 May 2019 Reliable Features cULus Listed as Residential Sprinklers Push -On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 1650F (74°C) temperature rated fusible -link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 1650F (74°C) or 212OF (100°C) temperature rated fusible -link oper- ating element. Sprinklers with a 1650F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 1350F (57°C) temperature rated cover plate. Sprinklers with a 212OF (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 1650F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei- ther pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjust- ment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. Model RFC Series Residential Sprinklers Flat Concealed Pendent Model RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC76 cULus Listed Model RFC43 & RFC43LL Model RFC58 )M Model RFC Cover Plate Sprinkler Model Nominal K-Factor gpm/psi (1/min/bary/Z ) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20 (6.1 x 6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions Threads — Body Cup —� Tower Fusible Link — Deflector (retracted) Pin (extended) - Deflector (extended) 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling Bottom View 2-5/16" (58 mm) Dia. 3/16"(5mm' Model RFC Cover Plate i 3-5/16" (84 mm) Dia. —►{ N Ceiling Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 7 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 2 of 8 May 2019 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Model RFC43 & RFC43LL Sprinkler Components and Dimensions Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) - 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling Model RFC Cover Plate Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria 6 Bottom View , 2-5/16" (58 mm) Dia. - a-1 3-5/16" (84 mm) Dia. 3/16" (5 mm' Ceiling Minimum Flow and Residual Pressure Max. Coverage Area (2) Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (1/min) (bar) (1/min) (bar) 15 x 15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16 x 16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 3 of 8 May 2019 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Cover Plate Finishes Listings and Approvals cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL onlv) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Threads Body — Cup Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling Bottom View 2-5/16" (58 mm) Dia. Model RFC Cover Plate 3-5/16" (84 mm) Dia. �-- Ceiling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual PressureM Max. Coverage Area (Z) Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (1/min) (bar) (1/min) (bar) 16 x 16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18 x 18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20 x 20 20 16.7 21 18.4 (6.1 x6.1) (75.7) (1.15) (79.5) (1.27) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 4 of 8 May 2019 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Bottom View 2-5/16" (58 mm) y Dia. Threads _ Body _ Cup =_ Tower Fusible Link 1-7/8" (48 mm) +/- 3/8" (9 mm) Deflector (retracted) Nominal face of fitting to ceiling � Pin (extended) 7", 3/16"(5mm, """` Deflector (extended) Model RFC Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure') Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 5 of 8 May 2019 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed Model RFC76 Sprinkler Components and Dimensions Three Body Cup Towei Fusible Li Deflector (retra Pin (extern Deflector (extend 1-7/8" (48 mm) +/- 3/8" (9 mm) Nominal face of fitting to ceiling Model RFC Cover Plate Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria /o Bottom View ti 2-5/16" (58 mm) Dia. 3-5/16" (84 mm) Dia. 3/16" (5 mm) Ceiling Minimum Flow and Residual PressureN Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18 x 18 24 9.9 (5,5 x 5.5) (90.8) (0.68) 20 x 20 34 20 (6,1 x 6.1) (128.7) (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 6 of 8 May 2019 www.reliablesprinkler.com Cover Plate Finishes(') Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad (3) Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi -gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceilings') Ceiling Rating inch (mm) inch (mm) RFC30, RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 1350F RFC30LL (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 1350F(2) RFC43LL, RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, (84) (67) (13) (38 to 51) (13 to 25) or 1650F 3 RFC49LL (74°C) 1350F(2) RFC58, RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench -able protec- tive cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench -able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed us- ing the Model FC wrench by temporarily removing the protec- tive cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permit- ted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engag- es the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-Ibs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-Ibs (19 to 27 N-m) for 3/4" thread sprinklers. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprin- klers are available in either ordinary or intermediate tempera- ture classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (38°C) or 150OF (660C), respectively. Bulletin 006 May 2019 Page 7 of 8 www.reliablesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench -able cap installed Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire -protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Model W3 For use with Model RFC Series sprinklers with wrench -able cap installed Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC • Model W3 v co co co co 0 N Bulletin 006 Reliable Page 8 of 8 May 2019 www.reliablesprinkler.com Bulletin 033 February 2019 Rellablia Model 171 RES LL Residential Sprinklers Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. Types: 1. F1 Res 30 LL Pendent 2, F1 Res 30 LL Recessed Pendent/F2 3, F1 Res 30 LL Recessed Pendent/FP 4. F1 Res 49 LL Pendent 5. F1 Res 49 LL Recessed Pendent/F1 6. F1 Res 49 LL Recessed Pendent/FP 7. F1 Res 58 LL Pendent 8. F1 Res 58 LL Recessed Pendent/F1 9. F1 Res 58 LL Recessed Pendent/FP 10. F1 Res 30 LL CCP Pendent 11. F1 Res 49 LL CCP Pendent 12. F1 Res 58 LL CCP Pendent 13. F1 Res 44 LL HSW 14. F1 Res 44 LL Recessed HSW/F2 15. F1 Res 58 LL HSW 16. F1 Res 58 LL HSW Recessed HSW/F2 17. F1 Res 44 LL SWC Pendent/F1, F1 Res 30 LL Recessed Pendent/F2 Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) for Safety to ANSI/ U L 1626. 2. Certified by Underwriters Laboratories, Inc. and Under- writers Laboratories of Canada for Health Effects to NSF/ ANSI Standard 61 Annex G (Less than 0.25% Lead Con- tent,) 3, WaterMark certified. WaterMark Certificate Number 23347 Additional Bulletins applicable to all F1 RES LL Sprinklers • Wall Wetting - Bulletin 007 • Design and Installation - Bulletin 140 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 LL & 58 LL Pendent Sprinklers Other patents pending. LL Recessed Pendent/FP 11 Pendent 11 CCP Pendent HSW Recessed HSW/F2 SWC Product Description Model F1 Res LL Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass -bulb and low profile decorative design. The F1 Res LL Horizontal Sidewall sprinklers (Figs. 5, & 6) are equally attractive when above ceiling piping cannot be used. The 3mm glass -bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in resi- dential fire protection design. The low flow F1 Res LL sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat -sensitive glass -bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass -bulb • Sprinkler Frame : Brass • Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: 1/2" NPT (R1/2) • K-Factor: 3.0 (Actual) - F1 Res 30 LL Pendent Sprinkler 4.9 (Actual) - F1 Res 49 LL Pendent Sprinkler 5.8 (Actual) - F1 Res 58 LL Pendent & HSW Sprinkler 4.4 (Actual) - F1 Res 44 LL HSW Sprinkler Cj m 0 W co CD 71 0 z. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res LL sprinklers are cULus Listed in accor- dance with UL 1626 for installation in accordance with NFPA 13, NFPA 13R, and NFPA 13D. Sprinkler systems using Model F1 Res LL sprinklers must be hydraulically designed to provide at least the flow identified in the Tech- nical Data tables in this bulletin. For NFPA 13 installations, the flow per sprinkler must be the greater of: (1) the flow listed in the applicable Technical Data table and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For cover- age area dimensions less than those listed in the Technical Data tables, use the minimum required flow for the next larger max. coverage area listed. • Model F1 Res 30 LL, 49 LL & 58 LL Pendent 135FG03 Fig. 1 Installation Models F1 Res LL sprinklers are to be installed as shown, Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res LL sprinklers, Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res LL Pendent sprinklers use only the Model W2 sprin- kler Wrench; for installing Models F1 Res LL Recessed • Model F1 Res 30 LL Recessed Pendent / F2 • Model F1 Res 49 LL & 58 LL Recessed Pendent / F1 2 1/4" HDLE DIA. [51.2mm] 1 IS/I6" DIA. [49.2mm] f/ - 1"X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. I I FACE OF FITTING TO CEILING DIMENSION: TJT�/ 3/I6-15/16 (F1 ESCUTCHEON) 3/16-11/16 (F2 ESCUTCHEON) ADIUSTMENT ®��� I [3�2mmJ A" 135FGO2A 2 27/32" Du. [7z2mm] Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 LL Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 LL with a ceiling to de- flector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. Fig. 2 Escutcheon*, F1 or F2, Data: Adjustment „A„ Face of fitting Type Inch (mm) Inch (mm) to ceiling Inch (mm) F1 3/4 (19.0) Min.=3/4" (19.1) 3/16 - 15/16 Max. =11/2" (38.1) (4.7 - 24.0) F2 1/2 (12.7) Min.=15/16" (23.8) 3/16 - 11/16 Max. =11/2" (38.1) (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 LL & 58 LL Recessed Pendent Sprinkler 2. Technical Data: F1 Res 30 LL Pendent and Recessed Pendent (SIN RA3311) Thread Size Nominal Orifice Inch mmpsi(bar) Max. Pressure Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch mm OF °C OF °C 1/2" NPT 21/64" (8.2) 175 (12) 155 68 100 38 3.0 (43.2) 2.25 (57) R1/z 175 79 Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing 155°F/68°C 175°F/79°C Top of Deflector to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Inch (mm) Ft (m) GPM (L/min) PSI(bar) GPM (L/min) PSI(bar) Ft (m) 12 x 12 (3.6 x 3.6) 12(3.6) 8(30.3) 7.0 (0.48) 8(30.3) 7.0 (0.48) Smooth Ceilings 1" to 4" (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 10 (37.8) 11 (0.76) 10 (37.8) 11 (0.76) 16 x 16 (4.9 x 4.9) 16(4.9) 13 (49) 18.8 (1.3) 13 (49) 18.8 (1.3) Technical Data: F1 Res 49 LL Pendent and Recessed Pendent (SIN RA3316) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Tem . Ratin °F °C Ambient Temp. K Length OF °C psi bar 155 68 Factor Inch mm 1/2" NPT 7/16" (11) 175 (12) 100 38 4.9 (70.6) 2.25 (57) RYz 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155°F/680C 175°F/790C to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) (mm) Ft (m) GPM min PSI a GPM min PSI(bar)Inch Smooth Ceilings 1" to 4" (25mm to 100mm) 8(2.4) 12 x 12 (3.6 x 3.6) 12(3.6) 13 (49) 7.0 (0.48) 13 (49) 7.0 (0.48) 14 x 14 (4.3 x 4.3) 14(4.3) 13 (49) 7.0 (0.48) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 16(4.9) 13 (49) 7.0 (0.48) 13 (49) 7.0 (0.48) Beamed Ceilings per NFPA 13, 13D, or 13R 18 x 18 (5.5 x 5.5) 18(5.5) 17 (64.3) 12 (0.83) 17 (64.3) 12 (0.83) 20 x 20 (6.1 x 6.1) 20(6.1) 20 (75.7) 16.7 (1.14) 20 (75.7) 16.7 (114) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 155°F/68°C(175'F/79'C) Intermediate Temp. Rating Top of Deflector to In Ceiling (mm) Minimum Spacing Ft (m) Flow GPM min Pressure PSI Flow GPM min Pressure PSI(badInch 12 x 12 (3.6 x 3.6) 12(3.6) 15 (57) 9.4 (0.65) 15 (57) 9.4 (0.65) Smooth Ceilings 4" to 8" (100mm to 200mm) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 16 (60.5) 10.6 (0.73) 16 (60,5) 10.6 (0.73) 16 x 16 (4.9 x 4.9) 16(4.9) 17 (64.3) 12.0 (0.83) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72) 15.0 (1.0) 19 (72) 15.0 (1.0) 20 x 20 (6.1 x 6.1) 20(6.1) 22 (83.2) 20.2 (1.4) 22 (83.2) 20.2 (1.4) 3. Technical Data: F1 Res 58 LL Pendent and Recessed Pendent (SIN RA3313) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Temp. Ratin Ambient Temp. K Factor Length OF °C °F °C psi (bar) Inch (mm) 1/2" NPT 1/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.25 (57) (R1/2) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155°F/680C 1750F/790C to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) In (mm) Ft (m) GPM min PSI a GPM Umin PSI(bar)Inch 12 x 12 (3.6 x 3.6) 12(3.6) 16 (61) 7.6 (0.53) 16 (61) 7.6 (0.53) Smooth Ceilings 1" to 4" (25mm to 100mm) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 16 (61) 7.6 (0.53) 16 (61) 7.6 (0.53) 16 x 16 (4.9 x 4.9) 16(4.9) 16 (61) 7.6 (0.53) 16 (61) 7.6 (0.53) Beamed Ceilings per NFPA 13, 13D, or 13R 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72) 10.8 (0.75) 19 (72) 10.8 (0,75) 20 x 20 (6.1 x 6.1) 20(6.1) 22 (83,3) 14.4 (1.0) 22 (83.3) 14.4 (1.0) • Model F1 Res 30 LL, 49 LL & 58 1 1 f! D 0--A-n+ 2 518" [66.7mml DIA. 2 5116" DIA. HOLE IN CEILING [58.7mm] CUP V 1 "x1/2" REDUCER CUP / CEILING 1 114» [31.5mm] WStltl MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION A» B' COVER ADJUSTMENT HEIGHT 3 5116» DIA. 135FG04D [84.1 mm] Fig. 3 • Model F1 Res 30 LL, 49 LL & 58 LL RP_CP_CCPrI PPnr1pnt / FP rr pusn-on/tnreaa-OTT escutcneon 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP / I � 1" X 1/2" REDUCER I 1 I I L J CEILING ®.iPV01 dd�� MM 99 1 1/2" [38.1mm] MAX. FACE OF flTTING -- - TO FACE OF CEILING �� DIMENSION J_ 1/2" [13mm] MAX \ FP ADJUSTMENT A IJ5FG01A Fig. 4 4 Technical Data: F1 Res 30 LL CCP Pendent and Recessed Pendent/FP (SIN RA3311) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Tem . atin Ambient Temp. Factor Length °C OF oC Inch mm psi (bar)OF Inch mm 1/2" NPT (RI/2) "/64" (8.2) 175 (12) 135 57 100 38 3.0 (43.2) 2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating 155°F/68°C Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Vmin) Pressure PSI bar 12 x 12 (3.6 x 3.6) 12(3.6) 8(30.3) 7.0 (0.48) Smooth Ceilings 1/2" to 1" (13mm to 25mm) using CCP or FP escutcheon 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 11 (37.8) 13.4 (0.92) Beamed Ceilings per NFPA 13, 13D, or 13R Technical Data: F1 Res 49 LL CCP Pendent and Recessed Pendent/FP (SIN RA3316) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. RatingAmbient Temp. Factor Length OF °C OF oC Inch (mm) psi (bar) Inch (mm) 1/2" NPT (R'/2 ) 7/16" (11) 175 (12) 135 57 100 38 4.9 (70.6) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum ea Max. Spacing (155°F/68°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ftr(m x m) Ft (m) Inch (mm) (m)g 12(3.6) GPM (Vmin) PSI (bar) Smooth Ceilings 1/2" to 1" (13mm to 25mm) using CCP or FP 8(2.4) 12 x 12 (3.6 x 3.6) 13 (49) 7.0 (0.48) 14 x 14 (4.3 x 4.3) 14(4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 16(4.9) 14 (53) 8.2 (0.56) escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 18 x 18 (5.5 x 5.5) 18(5.5) 18 (68.1) 13.5 (0.93) 20x20(6.1 x6.1) 20(6.1) 20(75.7) 16.7(1.14) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 LL CCP Pendent and Recessed Pendent/FP (SIN RA3313) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. Ratin Ambient Temp. Factor Length OF °C OF OC Inch (mm) psi (bar) Inch (mm) 1/2" NPT (R'/2 ) 1/2" (13) 175 (12) 135 57 100 38 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155°F/68°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) (m) GPM (Vmin PSI(bar)Ft 12 x 12 (3.6 x 3.6) 12(3.6) 16 (61) 7.6 (0.53) 14 x 14 (4.3 x 4.3) 14(4.3) 16(61) 7.6(0.53) Smooth Ceilings 1/2" to 1" 16 x 16 (4.9 x 4.9) 16(4.9) 16 (61) 7.6 (0.53) (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8(2.4) 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 20(6.1) 22 (83.3) 14.4 (1.0) 5. rll�"� 1 FACE OF FITTING TO WALL DIMENSION 1 1/4 ` MIN. [31.8mm] 2 1/4" HOLE DIA. 1/8 'q" [57.2mm] CEILING TO [3.2mm] DEFLECTOR 1" X 1/2- REDUCER DIMENSION ro� Illi lip I �--r1 �� IIIIIIII 1 15/16" DIA. [49.2mm] hill IIIII 2 27/32" DIA. IIIII [72.2mm] _IlIV V TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. l� `\ 1/2- [13mm] IJ5FG06-D ADJUSTMENT • Model F1 Res 44 LL & 58 LL HSW (r _ � .' �. ice► Rom, � •�,, 1 • Model F1 Res 44 LL & 58 LL Recessed HSW/F2 escutcheon, 1 2" (13mm) adjustment Technical Data: F1 Res 44 LL HSW & HSW/F2 (SIN RA3331) Nominal Max. Sprinkler Max. Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Size Inch (mm) psi (bar) Temp. Factor Inch (mm) of °C 1/2" NPT 3/8" (10) 175 (12) 155 68 100 38 4.4(63) 2.45 (62) (R/2) 175 79 150 66 Escutcheon. F2. Data: Face of T Type Adjustment to wetting ll Inch (mm) Inch (mm) F2 1/2 (1 3) 3/16 - 11/16 (4.7 - 17.4) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate (175°F/79°C) Temp. Rating Top of Deflector to Ceiling Inch (mm) 4 to 6 (100 to 152) Minimum Spacing Ft (m) 8(2.4) Flow Pressure GPM (L/min) PSI (bar) Flow GPM (Umin) Pressure PSI (bar) 12 x 12 (3.6 x 3.6) 12(3.6) 12 (45.4) 7.5 (0.52) 12 (45.4) 7.5 (0.52) 14 x 14 (4.3 x 4.3) 14(4.3) 14 (53.0) 10.2 (0.71) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9 x 4,9) 16(4.9) 16 (60.6) 13.3 (0.92) 16 (60.6) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 16(4.9) 18 (68.1) 16.8 (0.53) 18 (68.1) 16.8 (0.53) 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72.0) 18.7 (1.29) 19 (72.0) 18.7 (1.29) 16 x 20 (4.9 x 6.1) 16(4.9) 23 (87.1) 27.4 (1.89) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6 x 3.6) 12(3.6) 14 (53.0) 10.2 (0.71) 14 (53.0) 10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3) 14(4.3) 16 (60.6) 13.3 (0.92) 16 (60.6) 13.3 (0.92) 16 x 16 (4.9 x 4.9) 16(4.9) 17 (64.4) 15.0 (1.04) 17 (64.4) 15.0 (1.04) 16 x 18 (4.9 x 5.5) 16(4.9) 20 (75.7) 20.7 (1.43) 20 (75.7) 20.7 (1.43) 16 x 20 (4.9 x 6.1) 16(4.9) 23 (87.1) 27.4 (1.89) 23 (87.1) 27.4 (1.89) on Technical Data: F1 Res 58 LL HSW & HSW/F2 (SIN RA3333) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Inch (mm) psi (bar) Inch (mm) OF °C °F °C 1/2" NPT 1/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.45 (62) (R1/2) 175 79 150 66 Max. Coverage area Ft x Ft (m x m) 12 x 12 (3.6 x 3.6) Max. Spacing Ft (m) Ordinary Temp. 155°F/68°C Rating Intermediate 1750F/79°C Temp. Rating Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM min)VPSI(bar)--GPM Pressure Flow Vmin Pressure PSI ar 12(3.6) 16 (60.6) 7.6 (0.53) 16 (60.6) 7.6 (0.53) 4 to 6 (100 to 152) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 18 (68.2) 9.7 (0.69) 18 (68.2) 9.7 (0.69) 16 x 16 (4.9 x 4.9) 16(4.9) 21 (79.5) 13.2 (0.91) 21 (79.5) 13.2 (0.91) 16 x 18 (4.9 x 5.5) 16(4.9) 25 (94.7) 18.6 (1.28) 25 (94.7) 18.6 (1.28) 16 x 20 (4.9 x 6.1) 16(4.9) 29 (109.8) 25.0 (1.73) 29 (109.8) 25.0 (1.73) 12 x 12 (3.6 x 3.6) 12(3.6) 22 (83.3) 14.4 (1.0) 22 (83.3) 14.4 (1.0) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3) 14(4.3) 22 (83.3) 14.4 (1.0) 22 (83.3) 14.4 (1.0) 16 x 16 (4.9 x 4.9) 16(4.9) 26 (98.4) 20.1 (1.39) 26 (98.4) 20.1 (1.39) 16 x 18 (4.9 x 5.5) 16(4.9) 31 (117.4) 28.6 (1.97) 31 (117.4) 28.6 (1.97) • Model F1 Res 44 LL SWC Technical Data: F1 Res 44 LL SWC SIN RA3331 4" to 12" [101.60mm To 304.80mm] 1 1/4" [31.75mm] Maximum Face Of Fitting To Wall Dimension PUSH ON COVER, THEN TURN TO ADJUST UNTIL TIGHT AGAINST WALL. I" X 1/2" Reducer id Recommended Well Hole 2 5/8" 2 5/16" [58.74mm]�-tiii - - - - -- [66.68mm] Dig. 3 5/16" Dig. L ignL-r- , [84.14mm] _ / Dio. -- TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER 1 21/32 WRENCH BOSS. [42. 07mm] IJ5FG07 1/2" [12.70mm] Adjustment Fig. 6 Nominal Max. Cover Max. Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size inch (mm) psi (bar) Rating Temp. Factor Inch (mm) OF °C OF °C 1/2" NPT (R1/2) a „ /s (10) 175 (12) 135 57 100 38 4.4(63) 2.45 (62) 7. Technical Data: F1 Res 44 LL SWC (SIN RA3331) continued Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 155°F/68°C Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Vmin) Pressure PSI bar 12 x 12 (3.6 x 3.6) 12(3.6) 13 (49.2) 8.7 (0.60) 4 to 6 (100 to 152) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9 x 4.9) 16(4.9) 17(64.3) 15.0(1.1) 16 x 18 (4.9 x 5.5) 16(4.9) 19 (71.8) 18.7 (1.13) 16 x 20 (4.9 x 6.1) 16(4.9) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6 x 3.6) 12(3.6) 14 (52.9) 10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3) 14(4.3) 15 (56.7) 11.7 (0.81) 16 x 16 (4.9 x 4.9) 16(4.9) 18(68.1) 16.8(1.16) 16 x 18 (4.9 x 5.5) 16(4.9) 20 (75.6) 20.7 (1.43) Maintenance Model F1 Res 30 LL, 49 LL, F1 Res 58 LL and F1 Res 44 LL Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Model F1 Res 30 LL, 49 LL & 58 LL Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Resi- dential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Deflector -to -ceiling distance listing shall be 1" to 4" maximum, unless specifically listed other- wise. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a PTFE-coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard fin- ish; [Bronze] [Chrome -plated] [White Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 49 LL & 58 LL Recessed Pendent/F1 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer's installation guidelines and the applicable installation standard. Deflector -to -ceil- ing distance listing shall be 1" to 4" maximum, unless spe- cifically listed otherwise. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a PTFE-coated Bel- leville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)], Sprinklers shall have a nominal K-factor of 3.0, 4.9 & 5.8. Standard finish; [Bronze] [Chrome -plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with'/2" adjustment (Model F2)] [with 3/4" adjustment (Model F1)] [of push -on and thread off design with'/2" adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F1 ] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP] SIN RA3311, RA3316 & RA3313 (Bulletin 033), A., Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent (Concealed) Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential concealed sprinklers engi- neered to provide a minimum design density of 0.05 gpm/ ft2 over the listed coverage area. Listed flows as speci- fied by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of 1550F (680C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a 1/2" cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C), A plastic protective cap shall be provided and factory in- stalled inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed, Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL CCP, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 44 LL Horizontal Sidewall Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of [ 1550F (680C)] [175°F (790C)], Sprinklers shall have a nominal K-factor of 4.4 (62,8). Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Special finish— specify]. Residential hori- zontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL, SIN RA3331 (Bulletin 033). Model F1 Res 44 LL Recessed Horizontal Sidewall Sprinkler Specifications Use description for the Model F1 Res 44 horizontal side - wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with 1/2" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL/F2, SIN RA3331 (Bulletin 033). Standard Finishes F1, F2, FP Sprinkler Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black Polyester White Painted Coated Special Application Finishes F1, F2, Sprinkler Cover Plates Escutcheons Bright Brass Bright Brass Bright Brass Black Plated Black Plated Black Plated Black Paint Black Paint Black Paint Off White Off White Off White Satin Chrome Satin Chrome Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. J011111 Recycled ® (800) 431-1588 Sales Offices Paper Relle labi (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 02/19 P/N 9999970411 Bulletin 157 September 2019 Features 1. Available in the following configurations: • Pendent with standard escutcheon • Pendent with Model HB extended escutcheon • Pendent with Model FP recessed escutcheon • Pendent with Model F1 recessed escutcheon • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon • Horizontal Sidewall with Model HB extended es- cutcheon • Horizontal Sidewall with Model FP recessed es- cutcheon (FM Standard Response) • Horizontal Sidewall with Model F1 recessed es- cutcheon (FM Standard Response) • Upright 2. Available with 1" NPT, ISO7-1R1, 3/4" NPT, or IS07- 1 R3/4 inlet fitting. 3. 3/4" NPT inlet fittings permit replacement of older 3/4" inlet dry sprinklers without changing to a larger sprin- kler fitting. 4. Sprinklers, escutcheons, and cover plates are avail- able in a wide variety of standard and special appli- cation finishes. 5. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corrosion Resistant. 6. Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- rations. FM Approved for 175 psi (12 bar). Product Description Model F3QR56 Dry sprinklers are quick -response, stan- dard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent, Dry Horizontal Sidewall, and Dry Upright configurations, Model F3QR56 Dry sprin- klers all use a 3 mm glass bulb operating element. See the Temperature Ratings table in this Bulletin for available tem- perature ratings. Model F3QR56 Dry sprinklers are intended for installation on wet -pipe, dry -pipe, or preaction sprinkler systems in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F3QR56 Dry Pendent and Sidewall sprinklers are available with a variety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F3QR56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Available sprinkler, escutcheon, and cover plate fin- ishes are identified in the Finishes table in this Bulletin. The Model F1 escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F3QR56 Dry sprinklers; the use of any other recessed escutcheon or cover plate Model F3QR56 Dry K5.6 (80 metric) Quick -Response, Standard Spray Sprinklers (See Fig. 1) (See Fig. 3) Recessed F1 Pendent (See Fig. 5) Horizontal Sidewall / HB (See Fig. 7) Recessed F1 Horizontal Sidewall (See Fig. 9) r� r ^ Pendent / HB (See Fig. 2) REPO Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) t Recessed FP Horizontal Sidewall (See Fig. 8) Upright (See Fig. 10) z. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 with Model F3QR56 Dry sprinklers will void all guarantees, warranties, listings and approvals. Inlet fittings are available with 1" NPT, ISO 7-1 R1, 3/4" NPT, or IS07-1 R3/4 threads. Sprinklers with 3/4" NPT and IS07- 1 R3/4 inlet fittings are intended primarily for replacement of existing 3/4" or IS07-1 R3/4 inlet dry sprinklers, but may also be used in new installations. See the Available Configurations, Listings, and Approvals table in this Bulletin for further information on Model F3QR56 Dry sprinklers. Available Configurations, Listings, and Approvals Available Sprinkler Sprinkler Escutcheon or Listings and Inlet Identification Model Cover Plate Length Approvals(') Threads Number (See Figs. 1-9) (SIN) Standard 2" to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon cULus, NYC 3/4" NPT or F1 Recessed Escutcheon 3-1/2" to 36" IS07-1 R3/4 (90 to 900 mm) FP Recessed Escutcheon CCP Cover Plate F3QR56 Dry Pendent Standard 2" to 48" R5714 Escutcheon (50 to 1200 mm) HB Extended Escutcheon 1" NPT F1 Recessed cULus, FM, NYC or Escutcheon Escutcheon 3-1/2" to 48" R1 (90 to 1200 mm) FP Recessed Escutcheon CCP Cover Plate Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus(2), NYC(2) 3/4" NPT 3-1/2" to 48" or IS07-1 R3/4 F1 Recessed Escutcheon (90 to 1200 mm) FP Recessed F F3QR56 Dry Escutcheon Horizontal Sidewall Standard 2" to 48" cULus (2� R5734 Escutcheon (50 to 1200 mm) , FM(3), NYC(2) HB Extended 3-1/2" to 48" Escutcheon (90 to 1200 mm)or 1" NPT 7-1 R1 IS07- F1 Recessed Escutcheon 3-1/2" to 48" cULus(2), FP Recessed (90 to 1200 mm) FM(3)(4), NYC(2) Escutcheon F3QR56 Dry N/A 5" to 48" cULus(2) 1" NPT or R5724 Upright (127 to 1200 mm) IS07-1 R1 (') For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. (2) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (3) FM Approved for Light Hazard only. (4) Model F3QR56 Dry Horizontal Sidewall with Model F1 or Model FP recessed escutcheon are FM Approved as Standard Response. 2. Patents Model F3QR56 Dry series sprinklers may be covered by one or more of the following patents; US Patent No. 5,775,431 US Patent No. 5,967,240 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2, Certified by FM Approvals (FM) 3, Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor; 5.6 gpm/psi"2 (80 L/min/bar'12) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry Pendent cULus, NYC See note below 250 psi (17.2 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Horizontal Sidewall cULus, NYC 4" to 6 " 250 psi (17.2 bar) 4" to 12" 175 psi (12 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Upright cULus See note below 175 psi (12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification necessary. Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceil- ing Temperature Listings and Approvals(') Ordinary Orange 135°F(57°C) 135°F (57°C) 100°F (38°C) cULus, FM, NYC Red 155 ° F ( 68 °C) Intermediate Yellow 175°F (79°C) 165°F (74°C) 150°F (66°C) cULus, NYC Intermediate I Green 200°F (93°C) 165°F (74°C) 150°F (66°C) cULus, FM, NYC High Blue 286°F (141°C) None 225°F (107°C) cULus, FMM, NYC 165°F (74°C) 150°F (66°C) cULus, NYC (') For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. (2) High temperature classification is FM Approved with Standard and Model HB escutcheons only. FinisheS4 Component Sprinkler Escutcheon') Cover Plate Bronze Brass(') White Paint White Polyester (2) White Polyester Standard Finishes Chrome Chrome Chrome Electroless Nickel PTFE(2) Electroless Nickel PTFE Satin Chrome Black Polyester (2) Special Application Finishes Black Polyester Black Paint Custom Color Paint Custom Color Polyester Customer Color Polyester Black Plating (') Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model F1 escutcheons are supplied with both the collar and escutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized steel with no further finish. (2) cULus Listed as a Corrosion Resistant Sprinkler. (3) Brass finish available for standard, Model F1, and Model FP escutcheons only. (4) Dry upright sprinkler available in standard bronze only. 3. Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) Dim. 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 2" to 36" (51mm to 914mm) in 1/4" (6mm) increments for 3/4" connections "A" Dimension [5z Hole 11 /4" [32 mm] Escutcheon Adjustment Nominal Escutcheon Position 1/4" [6 mm] Escutcheon Adjustment 1/4" [6 mr Nominal PI atrUS1-1 1 Fig. 1 3" [76 mm] DIA. m Fitting -itting :r Can ion 15/32" [12mm] 8" m] COMDRYDET1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C2 9 Model F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections i "A" Dimension 2-1/2" [64 mm] Dia. Hole in Ceiling i 1/2" [13mm] Escutcheon Adjustment T 1-1/4" [32mm] Norlinal Position of Escutcheon 1/2" [13mm] Escutcheon Adjustment COMDRYDET2 Fig. 2 3-1 /2" [89 mm] Escutcheon Dia. System tee Inlet fitting Ceiling Escutcheon Sprinkler Can Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Sprinkler Guard: Model C2 5. Model F3QR56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections "A" Dimension rz----- - --I--A� r System Tee Hole in Ceiling 1/4" [6 mm] Escutcheon Adjustment 1 Ceiling i Inlet Fitting Sprinkler Cup Escutcheon f3/4" [19 mm] Nom. Nominal Escutcheon Position 3-7/32" 1/4" [6 mm] Escutcheon Adjustment [82 mm] Dia. COMDRYDET3 Fig. 3 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. 91 Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/z" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections ----�-- I--------r--��11----f i 4__� _►- System Tee _ .,_ -._. "A" Dimension Hole in Ceiling 3/16" [5 mm] Cover Plate Adjustment 1 Ceiling I Nominal Cover Plate Position 3/16" [5 mm] Cover Plate Adjustment Fig. 4 i 3-5/16" [84 mm] Dia. Inlet Fitting Sprinkler Cup Model CCP 1/2 Cover Plate Assembly 7/8" 4���r[22 mm] COMDRYDET4 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. 7. Model F3QR56 Dry Pendent Sprinkler with Model F1 Recessed Escutcheon (SIN R5714) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections. 2-1/4" [57 mm] Dia. Hole in Ceiling "A" Dimension F z L_ ---I�r�-- -7` I PIII i iiil I - System Tee Inlet Fitting Collar 1/4" [6 mm] Escutcheon Adjustment 1 /8 Ceiling ,�[3 mm] Nominal Escutcheon Position Escutcheon 1/4" [6 mm] Escutcheon Adjustment 2-27/32" _ [72 mm] Dia. COMDRYDET5 Fig. 5 91 Model F30R56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) "A" Dim. 2 to 48" (51mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 2" to 36" (51mm to 914mm) in 1/4" (6mm) increments for 3/4" connections System Fitting COMDRYDET6 Sprinkler Can Inlet Fitting 2-1/8" [54 mm] Dia. Hole in Wall 1-1/4" [32 mm] Escutcheon Adjustment "A" Dimension Tor Ceiling 4 [102 mm] Min. 12" [305 mm] Max. 15/32" [12mm] 2-3/32" [53 mm] i 5/8" [16 mm] -- --- [76 mm] Fig. 6 1/4" [6mm] Nominal Protrusion 1/4" [6 mm] Escutcheon Adjustment Nominal Escutcheon Position Note: The sprinkler can protrudes 1/a" when escutcheon is in nominal position. Escutcheon adjustment provides '/a" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. 91 Model F301356 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) "A" Dim. 3'/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 3/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections System Tee Inlet Fitting Ceiling � I 4" [102mm] Min. Escutcheon Sprinkler Can 2 3/32" [53mm] 12" [305mm] Max. 1 5/8" [16mm] Escutcheon eonDia. T 1 2 1/2" Dia. t Hole in Wall 1-1/4" 1-1/4" [32mm] Nominal Protrusion [32mm] 1/2" [13mm] Escutcheon Adjustment COMDRYDET7 1/2" [13mm] Nominal Position Escutcheon of Escutcheon Adjustment "A" Dimension — Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. 10. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2' to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections Ceiling Nom. 1-1/4" Escutcheon [32 mm] 4" [102 mm] Min. Sprinkler Cup cULus, NYC: 6" [152 mm] Max, System Tee FM: 12" [305 mm] Max. Inlet Fitting 5/8" [16 mm] 3-7/32" [82 mm] Dia. 2-1/2" [64 mm] Dia. Hole in Wall COMDRYDET8 1/4" [6 mm] Escutcheon Adjustment "A" Dimension • 1/4" [6 mm] Escutcheon Adjustment Nominal Escutcheon Position Note: Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. 11. Model F301356 Dry Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon (SIN R5734) 3'/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections System Tee _sue COMDRYDET9 Escutcheon Collar /— Inlet Fitting 2-1/4" [57 mm] Dia. Hole in Wall 1/4" [6 mm] Escutcheon Adjustment "A" Dimension Fig. 9 Nom. 1-3/4" 1/8" [44 mm] [3 mm] 4" [102 mm] Min. cULus, NYC: 6" [152 mm] Max. FM: 12" [305 mm] Max. 5/8" [16 mm] 2-27/32" [72 mm] Dia. 1/4" [6 mm] Escutcheon Adjustment Nominal Position of Escutcheon 12. Model F3QR56 Dry Upright (SIN 5724) Order Dimensions 5" to 48" (127 mm to 1219 mm) Note: Customer is responsible for determining correct deflector distance below structure above. Order Dimension Inlet Fitting System Tee - - COMDRYDET10 J J— _, j7�1 I �i�i�il I I i�i�i II II I \� Fig. 10 13. MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED TO A WET PIPE SYSTEM. WET PIPE AMBIENT TEMPERATURE EXPOSED TO DISCHARGE END OF SPRINKLER#(F EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50F/10'C 60'F/16'C EXPOSED MINIMUM BARREL LENGTH" CE OF FITTING TO TOP OF CEILING)= IN. (MM) IN. (MM) IN. (MM) 40-F (4'C) 0 0 0 30-F (-I Q) 0 0 0 20-F (-7°C) 4 (100) 0 0 107 (-12'C) 8 (200) 1 (25) 0 07 (-18'C) 12 (300) 3 (75) 0 -107 (-23'C) 14 (350) 4 (100) 1 (25) -207 (-29'C) 14 (350) 6 (150) 3 (75) -307 (-34'C) 16 (400) 8 (200) 4 (100) -40'F (-40'C) 18 (450) 8 (200) 4 (0) F 20 (500) 10 (250) 6 (150)10 -607 (-51'C) 20 (500) 10 (250) 6 (150) . FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. " THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. * THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED LENGTH AREA AND CONSEQUENT FORMATION OF A CONDENSATE AROUND THE FRAME, WHICH DIMENSION CLEARANCE COULD INHIBIT OPERATION OR CAUSE HOLE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. ______ ZEEINSIDE SURFACE OF INSULATION, WALL, OR CEILING THERMAL ESCUTCHEON BARRIER DISCHARGE END OF SPRINKLER PROTECTED (NON -CONDITIONED) AREA) RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) WET PIPE rt----------�� _ rt--- ---1�--� - -�IIII11IIII- 4- I I�1I1�- � 1�1�1Tt___�I (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH (SEE ABOVE) DECKFLASHING RASCO #4003910 INSIDE FACE LENGTH (SEE ABOVE) (RECOMMENDED) [SEAL CLEARANCE HOLE INSULATED FREEZER, ....... OR COOLER STRUCTURE OR EXTERIOR FRAMING (PROTECTED AREA) DISCHARGE END OF `__'=tr (PROTECTED AREA) OF DISCHARGE END DRY SPRINKLER DRY SPRINKLER IN COLD AREA IN COLD AREA COMDRYDETI *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet -pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal Obstruction Obstruction I I Female Female Pipe Pipe Thread f I Thread CPVC Fitting with Internal Obstruction CPVC Fitting - No Internal Obstruction 1 Shorter Longer Inlet Inlet Male Male Pipe Pipe Thread Thread I177 Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDE2 Fig. 12 15. ON Fig. 13 - Model F3R Wrench Fig. 14 - Model XL02 Wrench 16. MATERIAL SPECIFICATIONS ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TU BE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS 038000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL (NOT USED ON ALL MODELS) (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) COMDRYDET13 ,PPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL Fig. 15 17. Installation Instructions Model F3QR56 Dry sprinklers must only be installed in the following fittings: 1. The side outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee 2. The run outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee, with the side outlet plugged (wet -pipe systems only) 3. Spears Manufacturing Company Brass Thread In- sert Style or Special Reinforced Plastic Thread Style Listed adapter or tee (wet -pipe systems only) (gasket sealed outlets shall not be used) 4. Any Listed CPVC sprinkler adapter or tee only in ac- cordance with Fig. 12 and upon verification that the CPVC adapter or tee does not interfere with the sprin- kler's inlet (wet -pipe systems only) (gasket sealed outlets shall not be used) Model F3QR56 dry sprinklers must not be installed into el- bows, welded outlets, gasket sealed outlets, or couplings. Installation of the Model F3QR56 Dry sprinkler is not recom- mend in copper pipe systems, as this may reduce the life expectancy of the sprinkler. In all dry -pipe system installations, the Model F3QR56 Dry sprinkler must be installed with protrusion into the fitting in accordance with Fig. 1 through Fig. 10 in this Bulletin. Do not install Model F3QR56 Dry sprinklers with the standard (long) inlet fitting into CPVC fittings that have an internal obstruction (see Fig. 12); this will damage the sprinkler, the fitting, or both. Model F3QR56 Dry sprinklers are available with a short "PL" inlet fitting for installation on CPVC fittings of wet -pipe sprinkler systems only. Model F3QR56 Dry sprinklers connected to wet -pipe sys- tems must be installed with the Exposed Minimum Barrel Length required by Fig. 11 located in a Heated Area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4" NPT and ISO7-1 R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: 1. Cut a hole in the wall or ceiling directly in -line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3R wrench is designed to be inserted into the groves in the sprinkler's wrench boss as shown in Fig. 13. The Model XLO2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 14. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or remov- ing the wrench from the sprinkler, care should be tak- en to prevent damage to the sprinkler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to max- imum installation torque is 22 - 30 lb-ft (30 — 40 N-m) for 1" NPT and IS07-1R1 sprinklers, and 14 - 20 lb-ft (19 — 27 N-m) for 3/4" NPT and ISO7-1 R3/4 sprinklers. 3a.Alternatively, where access to the outer tube of the sprinkler is available, the Model F30R56 Dry sprinkler may be installed using a pipe wrench. The pipe wrench shall only be permitted to inter- face with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 15). Do NOT wrench any other portion of the sprinkler assembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprin- kler because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 — 40 N-m) for 1" NPT and ISO7-1 R1 sprinklers, and 14 - 20 lb-ft (19 — 27 N-m) for 3/4" NPT and ISO7-1 R3/4 sprinklers. 4. Standard and Model HB escutcheons can be in- stalled by slipping the escutcheon over the can until the escutcheon is seated against the ceiling or wall. Model F1 escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP es- cutcheon is installed by pressing or threading the es- cutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter -clockwise direc- tion. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cover plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter -clockwise direction. 5. Remove the orange protective clip when placing the sprinkler system in service. 18. Installation Data Sprinkler Suggested Hole Diameter Required Centerline of Sprinkler Installation Model Escutcheon or Cover Plate in Wall or Ceiling Tube/Inlet to Finished Ceiling Wrench Vertical Dimension* Standard Escutcheon 2-1/8"(54 mm) F3R HB Extended Escutcheon 2-1/2" (64 mm) F3QR56 Dry Not F1 Recessed Escutcheon 2-1/4" (57 mm) Pendent Applicable FP Recessed Escutcheon XL02 2-1/2" (64 mm) CCP Cover Plate Standard Escutcheon 2-1/8" (54 mm) 4-5/8" to 12-5/8" (118 mm to 321 mm) F3R HB Extended Escutcheon 2-1/2" (64 mm) F3QR56 Dry F1 Recessed Escutcheon 2-1/4" (57 mm) cULus, NYC Horizontal Sidewall 4-5/8" to 6-5/8" 118 mm to 168 mm ( ) FP Recessed Escutcheon 2 1/2" (64 mm) F1 Recessed Escutcheon 2-1/4" (57 mm) FM XL02 4-5/8" to 12-5/8" FP Recessed Escutcheon 2-1/2" (64 mm) (118 mm to 321 mm) F301356 Dry N/A 1-1/2" (38mm) Not Applicable F3R Upright *Note: Based on 5/8" (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3QR56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sen- sitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by us- ing a soft brush or gently vacuuming. Replace any sprin- kler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or op- erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Ordering Information Specify: 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] [Model F3QR56 Dry Horizontal Sidewall SIN R5734] [Model F2QR Dry Upright SIN R5724] 2. Escutcheon/Cover Plate: [None][Standard escutch- eon][Model HB extended escutcheon][Model F1 re- cessed escutcheon][Model FP recessed escutcheon] [Model CCP cover plate — pendent only] 3. Inlet Threads: [1" NPT][ISO7-1R1][3/4" NPT][IS07- 1 R3/4] 4. Inlet Fitting: [Long — Standard Inlet Fitting][Short "PL" — Wet Pipe Systems only] 5. Sprinkler Temperature Rating: See Temperature Rat- ings table 6. Sprinkler Finish: See Finishes Table 7. Escutcheon/Cover Plate Finish: See Finishes Table 8. Length: *For dry pendents and dry sidewalls: "A" Dimen- sion is from face of tee to face of finished ceiling or wall in 1/4" (6mm) increments. See Fig. 1 through Fig. 9. *For dry uprights: Order dimension is from face of tee to top of deflector in 1/4" (6mm) increments. See Fig. 10. Notes: 1. For Dry Upright, customer is responsible for determining the correct deflector distance from structure above. 2. Length is based on normally gauged pipe thread "make- up" of .600" (15mm) per ANSI B2.1 (approximately 7-1/2 threads). The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ®Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 09/19 P/N 9999970175 UponorAquaPEX®White, coils Submittal information Revision M: Sept. 18, 2018 Project information Job name: Location: Part no. ordered: Uponof Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Crosslinked polyethylene PEX-a Engel Method; PEX 5106 Standard grade hydrostatic ratings (PPI): 200°F (93°C) at 80 psi (551 kPa) 180°F (82°C) at 100 psi (689 kPa) 73.4°F (23°C) at 160 psi (1,103 kPa) '/2", %", 1", 1'/4", 1'/2" and 2" UponorAquaPEX® White only: --- 120°F (49°C) at 130 psi (896 kPa) Linear expansion rate: 1.1'/10°F/100' (27.94mm/5.56°C/30.48m) Product information and application use Uponor AquaPEX White is used for hot and cold domestic potable water distribution and residential fire safety as well _ as radiant heating/cooling and hydronic piping systems containing no ferrous corrodible components or where ferrous components are isolated from the piping. ✓ Description Part number I.D. O.D. Weight '/4' Uponor AquaPEX White, 100-ft. coil F1040250 0.241" 0.375" 4.0 lbs. Uponor AquaPEX White, 400-ft. coil F1090375 0.350" 0.500" 20.0 lbs. Uponor AquaPEX White, 1,000-ft. coil F1120375 0.350" 0.500" 44.0 lbs. ''/2" Uponor AquaPEX White, 100-ft. coil F1040500 0.475" 0.625" 6.0 lbs. %" Uponor AquaPEX White, 300-ft. coil F1060500 0.475" 0.625" 18.0 lbs. ''/z" Uponor AquaPEX White, 500-ft. coil F1100500 0.475" 0.625" 27.6 lbs. ''/z" Uponor AquaPEX White, 1,000-ft. coil F1120500 0.475" 0.625" 54.0 lbs. Uponor AquaPEX White, 300-ft. coil F1060625 0.574" 0.750" 28.0 lbs. Uponor AquaPEX White, 1000-ft. coil F1120625 0.574" 0.750" 86.0 lbs. Uponor AquaPEX White, 100-ft. coil F1040750 0.671" 0.875" 10.0 lbs. Y44" Uponor AquaPEX White, 300-ft. coil F1060750 0.671" 0.875" 34.0 lbs. %" Uponor AquaPEX White, 500-ft. coil F1100750 0.671" 0.875" 54.0 lbs. 1" Uponor AquaPEX White, 100-ft. coil F1041000 0.862" 1.125" 20.0 lbs. 1" Uponor AquaPEX White, 300-ft. coil F1061000 0.862" 1.125" 56.0 lbs. 1" Uponor AquaPEX White, 500-ft. coil F1101000 0.862" 1.125" 93.0 lbs. 1'/4' Uponor AquaPEX White, 100-ft. coil F1061250 1.054" 1.375" 34.0 lbs. 1'/4" Uponor AquaPEX White, 300-ft. coil F1021250 1.054" 1.375" 106.0 lbs. 1'/z" Uponor AquaPEX White, 100-ft. coil F1061500 1.244" 1.625" 44.0 lbs. 1'/z" Uponor AquaPEX White, 300-ft. coil F1021500 1.244" 1.625" 133.0 lbs. 2" Uponor AquaPEX White, 100-ft. coil F1062000 1.629" 2.125" 68.2 lbs. 2" Uponor AquaPEX White, 200-ft. coil F1052000 1.629" 2.125" 136.4 lbs. 2" Uponor AquaPEX White, 300-fit. coil F1022000 1.629" 2.125" 204.6 lbs. 2'/i' Uponor AquaPEX White, 100-ft. coil F1062500 2.011" 2.625" 88.0 lbs. 2'/i' Uponor AquaPEX White, 300-ft. coil F1022500 2.011" 2.625" 264.0 lbs. 3" Uponor AquaPEX White, 100-ft. coil F1063000 2.400" 3.125" 128.0 lbs. 3" Uponor AquaPEX White, 300-ft. coil F1023000 2.400" 3.125" 384.0 lbs. Installation Use ProPEX® fittings for %" through 3" pipe.' Refer to the ProPEX Connections Instructional Guide, Uponor Piping Pocket Guide, Plumbing Design Assistance Manual (PDAM), Complete Design Assistance Manual (CDAM), Hydronic Piping Design Assistance Manual (HPDAM) or AquaSAFET1A Residential Fire Sprinkler Installation Guide for more information. Listings2 Codes Standards cNSFus-fs3; cNSFus-pw; cQAlus P321; UL; IAPMO; ICC; IPC; IMC; IRC; ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM CSA; PPI TR-4; ICC-ES; BMEC; CCMC UPC; UMC; NSPC; HUD; F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; UFGS; NPC of Canada; ASTM E814/ULC S115; CSA B137.5; CSA B214; NBC of Canada UL 18213; ULC/ORD-C199P3; AWWA C9044 Related applications Contact information PEX-a plumbing systems Uponor, Inc. Uponor Ltd. AquaSAFETM fire safety systems 5925 148"' Street West 6510 Kennedy Road Radiant heating and cooling systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Hydronic piping systems Phone: 800.321.4739 Phone: 888.994.7726 Fax: 952.891.2008 Fax: 800.638.9517 uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEX- is a trademark of Uponor Ltd. 2Visit listing agency's website for complete information. 3For 3/4", 1" and 1'W pipe only. 4For %" to 3" pipe. ProPEX° Ring Submittal information Revision I: Nov. 1, 2018 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Engel -method crosslinked polyethylene (PEX-a) Density: 926 to 940 kg/m3 Degree of crosslinking: 70% to 89% Product information and application use Uponor ProPEX® rings are required to make a proper ProPEX connection.' The ProPEX ring with stop includes a leading edge chamfer and stop edge. ✓ Description Part number ProPEX Ring, %" ProPEX Ring with Stop, '/2" ProPEX Ring with Stop, %" ProPEX Ring with Stop, 3/4" ProPEX Ring with Stop, 1" ProPEX Ring with Stop, 1'/4" ProPEX Ring with Stop, 1'/2" ProPEX Ring with Stop, 2" ProPEX Ring with Stop, 2'/2" ProPEX Ring with Stop, 3" Installation Q4690302 Q4690512 Q4690625 Q4690756 Q4691000 Q4691250 Q4691500 Q4692000 Q4692500 Q4693000 uponof Length I.D. O.D. Weight 0.54" 0.49" 0.74" 0.005lbs. 0.63" 0.63" 0.87" 0.006lbs. 0.79" 0.75" 1.00" 0.008lbs. 0.87" 0.88" 1.13" 0.012lbs. 1.10" 1.13" 1.42" 0.020lbs. 1.35" 1.38" 1.66" 0.030lbs. 1.61" 1.63" 1.91" 0.040 lbs. 1.97" 2.14" 2.61" 0.133lbs. 2.61" 2.66" 3.25" 0.230lbs. 3.12" 3.16" 3.87" 0.400lbs. Square cut the Uponor PEX tubing. Remove excess material. Slide the ProPEX ring over the end of the tubing (maximum 'lid' over -hang for rings without stop). When using the ProPEX ring with stop, slide the ring on the tubing with the chamfered edge first until the end of the tubing contacts the stop edge. Expand the tubing and ring. If using the ProPEX Manual Expander Tool, rotate the tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. Make ProPEX connections at temperatures above 5°F/-15°C. For more information, refer to the Uponor ProPEX Connections Instructional Guide. Listings' cNSFus-fs3; cNSFus-pw; cNSFus-rfh; cQAlus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC; cQAlus P321 Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; CSA 13137.5; CSA B214; UL 18213; ULC/ORD-C199P3 Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. AquaSAFE fire safety systems 5925 148"' Street West 6510 Kennedy Road Hydronic radiant heating and cooling systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Snow melting systems Phone: 800.321.4739 Phone: 888.994.7726 Turf conditioning systems Fax: 952.891.2008 Fax: 800.638.9517 Permafrost prevention systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEXT" is a trademark of Uponor Ltd. 2Visit listing agency's website for complete information; 3For '/2",'/", 1", 11/", 1'/2" and 2" tubing only ProPEXO Engineered Submittal information Revision H: May 23, 2019 Project information Job name: Polymer (EP) Tee Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved bv: Technical data Material: Engineered polymer (EP) Maximum temperature (no pressure): 320°F (160°C) Maximum working temperature/pressure: 210*F (99*C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) tees make diverting connections for Uponor crosslinked polyethylene (PEX-a)tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTM tubing.' Note: Branch size is listed last in the part descriptions. Uponof Part ✓ Equivalent Equivalent cv cv Description number A B Weight length (ft.) length (ft.) through branch through branch ProPEX EP Tee, ''M." PEX x'/z' PEX x'/" PEX Q4755060 2.50" 1.53" 0.02 lbs. 1.0 6.3 7.7 3.4 ProPEX EP Tee, %" PEX x'/:' PEX x'/:' PEX* Q4757575 3.30" 1.94" 0.05 lbs. 1.5 15.6 15.7 5.4 ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX* Q4751010 4.10" 2.47" 0.07 lbs. 1.3 12.7 30.5 11.3 ProPEX EP Tee, 1'/4" PEX x 1'/4" PEX x 1'/4" PEX* Q4751313 4.80" 3.22" 0.15 lbs. 3.8 8.6 34.0 23.9 ProPEX EP Tee, 1 Yz' PEX x 1'/." PEX x 1'M." PEX Q4751515 5.80" 3.82" 0.25 lbs. 1.8 10.6 63.7 31.0 ProPEX EP Tee, 2" PEX x 2" PEX x 2" PEX Q4752000 7.45" 4.79" 0.38 lbs. 0.8 15.5 150.7 52.5 ProPEX EP Tee, 21/' PEX x 21/z' PEX x 21/z' PEX Q4752500 10.56" 5.45" 1.14 lbs. 2.7 22.3 197.2 81.5 ProPEX EP Tee, 3" PEX x 3" PEX x 3" PEX Q4753000 12.26" 6.37" 1.86 lbs. 2.8 23.9 286.6 122.8 Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor Professional Plumbing Installation Guide, AquaSAFET"^ Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information PEX-a plumbing systems Uponor, Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 148t' Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFETm fire safety systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEXT" is a trademark of Uponor Ltd. ProPEX° Engineered Polymer (EP) Reducing Tee (up to 11/2") uponof Submittal information Revision I: Sept. 16, 2019 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Engineered polymer (EP) n� Maximum temperature (no pressure): 320°F (160°C) Max. working temperature/pressure: 210°F (99°C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) reducing tees make diverting connections for Uponor PEX-a pipe for use in hot and cold B domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX11 or Wirsbo hePEXTM pipe.' Note: Branch size is listed last in the part descriptions. ✓ Description Part A B Weight Equiv, length (ft.) Equiv. length Cv Cv number through (ft.) branch through branch ProPEX EP Reducing Tee,''/2" PEX x'/i' PEX x %" PEX Q4755575 2.86" 1.76" 0.03 lbs. 1.0 15.6 7.7 5.4 ProPEX EP Reducing Tee, '/<" PEX x'/i' PEX x'/i' PEX Q4757555 3.10" 1.70" 0.04 lbs. 3.5 6.4 4.6 3.4 ProPEX EP Reducing Tee, '/<" PEX x'/z' PEX x'/;' PEX* Q4757557 3.10" 1.94" 0.04 lbs. 2.3 16.1 5.4 5.4 ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x PEX Q4757563 3.30" 1.85" 0.05 lbs. N/A N/A N/A N/A ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x'/z' PEX* Q4757550 3.30" 1.70" 0.04 lbs. 2.0 7.6 14.2 3.1 ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x 1" PEX* Q4757710 3.64" 2.32" 0.08 lbs. 1.5 5.7 15.7 8.7 ProPEX EP Reducing Tee, 1" PEX x'/i' PEX x 1" PEX Q4751501 3.71" 2.43" 0.09 lbs. 1.98 9.7 12.3 5.7 ProPEX EP Reducing Tee, 1" PEX x'/d' PEX x'/ PEX Q4751750 3.65" 1.96" 0.07 lbs. 2.27 6.69 3.1 13.2 ProPEX EP Reducing Tee, 1" PEX x'/<" PEX x'/4" PEX* Q4751775 3.90" 2.24" 0.08 lbs. 2.4 16.7 12.8 5.3 ProPEX EP Reducing Tee, 1" PEX x'/<" PEX x 1" PEX* Q4751751 3.90" 2.47" 0.08 lbs. 2.4 15.1 12.9 10.5 ProPEX EP Reducing Tee, 1" PEX x'/;' PEX x 1%" PEX Q4751753 4.15" 2.95" 0.12 lbs. 2.74 19.48 14.7 12.0 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x'/;' PEX* Q4751150 4.10" 2.00" 0.08 lbs. 1.2 6.5 32.2 3.4 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x %" PEX* Q4751175 4.10" 2.24" 0.09 lbs. 1.7 6.4 27.8 8.2 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1 '/;' PEX* Q4751113 4.38" 2.95" 0.13 lbs. 6.52 5.37 15.0 28.0 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x'/<" PEX* Q4751377 4.11" 2.38" 0.09 lbs. 2.74 7.41 7.3 12.0 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x 1" PEX* Q4751371 4.37" 2.62" 0.11 lbs. 2.70 7.59 13.9 12.1 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x 1Y<" PEX* Q4751373 4.61" 2.88" 0.13 lbs. 2.74 11.91 18.8 12.0 ProPEX EP Reducing Tee, 1'/<" PEX x 1" PEX x %" PEX* Q4751317 4.50" 2.73" 0.11 lbs. 3.4 5.2 21.0 9.3 ProPEX EP Reducing Tee, 11/;' PEX x 1" PEX x 1" PEX* Q4751311 4.70" 2.97" 0.12 lbs. 11.0 23.0 11.7 8.4 ProPEX EP Reducing Tee, 11/;' PEX x 11/4" PEX x'/;' PEX* Q4751350 4.40" 2.15" 0.10 lbs. 1.9 3.9 45.2 4.1 ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x %" PEX* Q4751337 4.70" 2.73" 0.13 lbs. 2.3 5.7 43.4 8.9 ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x 1" PEX* Q4751331 5.00" 2.97" 0.14 lbs. 4.2 6.3 33.0 15.8 ProPEX EP Reducing Tee, 1'/z" PEX x'/<" PEX x %" PEX Q4751577 4.37" 2.64" 0.13 lbs. 2.88 7.41 7.3 11.7 ProPEX EP Reducing Tee, 1'/z" PEX x'/<" PEX x 1'/z" PEX Q4751575 4.97" 3.39" 0.19 lbs. 2.74 19.10 22.9 12.0 ProPEX EP Reducing Tee, 1'/z" PEX x 1" PEX x %" PEX Q4751517 5.25" 3.06" 0.17 lbs. 4.0 5.1 19.5 9.3 ProPEX EP Reducing Tee, 1'/z" PEX x 1" PEX x 1" PEX Q4751511 5.25" 3.30" 0.18 lbs. 4.3 6.5 18.9 15.6 ProPEX EP Reducing Tee, 11/2" PEX x 1" PEX x 11/2" PEX Q4751505 5.40" 3.45" 0.20 lbs. 4.2 14.9 19.0 26.5 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x %" PEX Q4751537 5.50" 2.65" 0.18 lbs. 4.2 11.3 33.1 6.3 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 1" PEX Q4751531 5.50" 2.85" 0.19 lbs. 3.1 13.1 36.4 11.2 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 11/4" PEX Q4751533 5.50" 3.15" 0.21 lbs. 2.0 17.7 45.4 17.0 ProPEX EP Reducing Tee, 1'/z" PEX x 1'/2" PEX x'/i' PEX Q4751550 4.95" 2.30" 0.14 lbs. 2.4 6.3 60.5 3.4 ProPEX EP Reducing Tee, 1'/z" PEX x 1'/2" PEX x %" PEX Q4751557 5.30" 3.06" 0.20 lbs. 2.9 5.4 56.0 9.0 ProPEX EP Reducing Tee, 1'/2" PEX x 1'/2" PEX x 1" PEX Q4751551 5.75" 3.30" 0.21 lbs. 3.1 6.9 53.8 15.3 ProPEX EP Reducing Tee, 1'/2" PEX x 1'/2" PEX x 11/4" PEX Q4751553 5.80" 3.56" 0.22 lbs. 3.2 4.1 54.3 33.7 Installation Use the appropriate ProPEX ring for PEX-a pipe. Refer to the Uponor Piping Systems Installation Guide, the AquaSAFETm Residential Fire Sprinkler Installation Guide or the Uponor Radiant Installation Handbook for additional information. Standards Codes Listings ASTM E84; ASTM E119; ASTM E814; IBC; IMC; IPC; IRC; NPC of Canada; cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ASTM F877; ASTM F1960; NSPC; UMC; UPC ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code CAN/CSA B137.5; NSF 14; NSF 61 Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 1481h Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFETM fire safety systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor Inc. ProPEX" is a trademark of Uponor Ltd. ProPEX® Engineered Polymer (EP) Elbow Submittal information Revision J: June 21, 2019 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: ADDroved bv: Technical data Material: Engineered polymer (EP) Maximum temperature (no pressure): 320°F (160°C) Maximum working temperature/pressure: 210°F (99°C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) elbows make 90-degree connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire safety and hydronic radiant heating and cooling systems. Each end of the elbow is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTm tubing.' Uponof ✓ Description Part number A B Weight Equivalent Cv length (ft.) ProPEX EP Elbow, '/z" PEX x'/z" PEX Q4760500 1.30" 1.30" 0.02 lbs. 10.4 2.6 ProPEX EP Elbow, 3/4° PEX x 3/4" PEX* Q4760750 1.60" 1.60" 0.03 lbs. 10.8 6.7 ProPEX EP Elbow, 1" PEX x 1" PEX* Q4761000 2.10" 2.10" 0.07 lbs. 11.5 11.9 ProPEX EP Elbow, 1'/4" PEX x 1'/4" PEX* Q4761250 2.45" 2.45" 0.11 lbs. 10.0 22.2 ProPEX EP Elbow, 1'/z" PEX x 1'/z" PEX Q4761500 2.77" 2.77" 0.18 lbs. 11.5 29.7 ProPEX EP Elbow, 2" PEX x 2" PEX Q4762000 3.76" 3.76" 0.30 lbs. 17.1 50.2 ProPEX EP Elbow, 2'/z" PEX x 2'/z" PEX Q4762500 4.93" 4.93" 0.85 lbs. 20.0 86.0 ProPEX EP Elbow, 3" PEX x 3" PEX Q4763000 5.88" 5.88" 1.44 lbs. 23.2 125.0 ProPEX EP 45 Elbow, 1'/2' PEX x 1'/2" PEX Q4761515 2.32" 2.32" 0.13 lbs. 9.3 33.1 ProPEX EP 45 Elbow, 2" PEX x 2" PEX Q4762020 2.91" 2.91" 0.32 lbs. 8.8 68.9 ProPEX EP 45 Elbow, 2'/2' PEX x 2'/2" PEX Q4762525 3.83" 3.83" 0.65 lbs. 7.0 136.8 ProPEX EP 45 Elbow, 3" PEX x 3" PEX Q4763030 4.48" 4.48" 1.07 lbs. 8.3 195.5 Installation Use the appropriate ProPEX ring for PEX-a tubing. Refer to the Uponor Piping Pocket Guide, AquaSAFETm Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 148t' Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFE fire safety systems uponorpro.com uponorpro.com 1 ProPEX® is a registered trademark of Uponor, Inc. ProPEX- is a trademark of Uponor Ltd. ProPEX° Fire Sprinkler Adapter Submittal Information Revision B: March 17, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: 300 Series Stainless Steel Product Information and Application Use Use the ProPEX° Fire Sprinkler Adapter in conjunction with the appropriate sprinkler to provide a multi -purpose residential fire sprinkler system'. For residential applications, the system is installed with the cold -potable portion of the Uponor plumbing system. Make connections with Uponor ProPEX fittings. These fittings are designed for use only with 3/4" or 1" AquaPEX° White tubing in the Uponor AQUASAFE° Looped System. uponof ✓ Description Part A B C D E Weight Number ProPEX Fire Sprinkler Adapter, 3/4" PEX x 1/2" FNPT Q7517550 0.75" 1.88" 2.50" 1.82" 1.41" 0.268 lbs. ProPEX Fire Sprinkler Adapter, 1" PEX x 1/2" FNPT Q7511050 0.75" 1.88" 2.50" 2.06" 1.54" 0.408 lbs. Installation Use appropriate ProPEX Ring for connecting the tubing. Refer to the AquaPEX Installation Handbook or the Uponor AQUASAFE° Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F 1960 Codes IPC; UPC; NSPC; IRC; IMC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; U.P. Code; ICC ESR 1099; HUD MR 1269; UL 1821; ULC/ORD - C 199 P Related Applications PEX-a Plumbing Systems AQUASAFE Fire Safety Systems Contact Information Uponor, Inc. 5925 1481h Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 'ProPEX° is a registered trademark of Uponor, Inc. ProPEXTM is a trademark of Uponor Ltd.