Clark-EnergyTable R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. h Reserved. 'The second R-value applies when more than half the insulation is on the interior of the mass wall. Reserved. k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. ResidenceClark _- MMEME _- MMEME _ EI©EMO M■ M■ M■ M■ ME M■ ME M■ M■ M■ M■ ME M■ bimme Heatina bmem bite: wasnlnaton State Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Clark Residence Heating System Type: O All Other Systems Q Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) I tlmands AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 4,043 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.8 39,419 Glazina and Doors U-Factor X Area = UA Instructions u-o.zs . 0.280 737 206.36 Skylights U-Factor X Area = UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructions R-49 V 0.026 2,590 67.34 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project. V--- Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21 Intermediate � 0.056 2,500 140.00 Floors U-Factor X Area UA Instructions 0.025 954 23.85 R-38 V Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions 0.042 500 21.00 R-21 InteYlor V Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions No Slah 6elaw Grade in this project. 0.303 --- Slab on Grade (see Figure v F-Factor X Length UA Instructions rl— 0.360 170 61.20� 70 Fully Insulated � Location of Ducts Instructions Duct Leakage Coefficient ` Unconditioned Space T 1.10 Sum of UA 519.75 Figure 1. Above Grade 46 Envelope Heat Load 23,909 Btu / Hour Sum of UA X AT Air Leakage Heat Load 19,583 Btu / Hour VolumeX 0.6XATX.018 Building Design Heat Load 43,492 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 47,841 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 66,978 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113)