Loading...
BLD2022-0143_Manufacturer_Specifications_and_Installation_Instructions_2.3.2022_2.08.44_PM_2660144AIR CONDITIONERS LE---7 NNOX RES/DENT/AL PROD UC T SPEC/FICA TONS T � A I LENNOX , o —Now MODEL NUMBER IDENTIFICATION 13ACXN MERIT° Series R-410A - 60 Hz Bulletin No. 210831 June 2020 Supersedes May 2010 MERIT° SERIES SEER up to 15.50 1.5to5Tons Cooling Capacity - 17,500 to 59,000 Btuh 13 AC X N 024 - 230 - 17 ------------- , Nominal SEER - Minor Revision Number Unit Type ------------- ; toltage AC =Air Conditioner30=208/230V 1 phase 60hz Refrigerant X = R-410A ' •------- Regional Standards---------- N = North Region Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons FEATURES HIGHLIGHTS 1. Condenser Fan 2. Copper Tube/Enhanced Fin Coil 3. Scroll Compressor 4. Heavy Gauge Steel Cabinet 5. Refrigerant Line Access CONTENTS Approvals And Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . 3 Contents...........................................................2 Controls - Order Separately . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Dimensions - Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Features...........................................................3 Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installation Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Model Number Identification................................................1 Optional Accessories - Order Separately . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 SoundData.........................................................9 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 TXV/Orifice Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 2 APPROVALS AND WARRANTY APPROVALS • AHRI Standard 210/240 certified • AHRI Certified system match -ups and expanded ratings, visit www.LennoxPros.com • Sound rated to AHRI Standard 270-2008 test conditions • Tested in the Lennox Research Laboratory environmental test room • Rated according to U.S. Department of Energy (DOE) test procedures • Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area. • Unit and components ETL, NEC and CEC bonded for grounding to meet safety standards for servicing • ETL certified (U.S. and Canada) • ISO 9001 Registered Manufacturing Quality System WARRANTY • Compressor: • Limited five years in residential installations • Limited five years in non-residential installations • All other covered components: • Limited fve years in residential installations • Limited one year in non-residential installations NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. FEATURES APPLICATIONS • 1.5 through 5 tons • Single phase power supply • Sound levels as low as 76 dBA • Vertical air discharge • Applicable to indoor air handlers or gas furnaces with indoor add -on coils © Copper Tube/Enhanced Fin Coil • Lennox designed and fabricated coil • Ripple -edged aluminum fins • Copper tube construction • Lanced fins for maximum fin surface exposure • Fin collars grip tubing for maximum contact area • Flared shoulder tubing connections • Shipped completely factory assembled, piped and wired • Silver soldering construction NOTE - Installer must set outdoor unit, connect refrigerant • Coil is factory tested under high pressure lines and make electrical connections to complete • Steel louvered panels provide complete coil protection job. • Panels can be completely removed for servicing REFRIGERATION SYSTEM R-410A Refrigerant • Non -chlorine, ozone friendly • Unit is factory pre -charged NOTE - Total system refrigerant charge is dependant on outdoor unit size, indoor unit size and refrigerant line length. NOTE - Refer to the unit -mounted charging sticker to determine correct amount of charge required. 0 Outdoor Coil Fan • Direct drive fan • Vertical air discharge • Louvered steel top fan guard • Totally enclosed fan motor • Ball bearings • Inherently protected High Capacity Liquid Line Drier • Furnished with unit for field installation • Drier traps moisture or dirt • 100% molecular -sieve, bead type, bi-flow drier High Pressure Switch • Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting • Automatic reset 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 3 FEATURES REFRIGERATION SYSTEM (continued) Refrigerant Flow Control • Units applicable to expansion valve systems or RFC systems when matched with specific indoor coils RFCIV: • Accurately meters refrigerant in system • Refrigerant control is accomplished by exact sizing of refrigerant metering orifice • The principle involves matching indoor coil with proper bore size of orifice in metering device RFCIV METERING SYSTEM ORIFICE BODY RFCIV (On Coil) "BULLET" ORIFICE O-RING o/ LIQUID � LINE LIQUID LINE SCREEN SEAL NUT SWEAT CONNECTION • Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls Optional Accessories Expansion Valve Kits • Field installed on certain indoor units • See TXV Usage Table • Chatleff-style fittings Freezestat • Senses suction line temperature • Cycles compressor off when suction line temperature falls below it's setpoint • Opens at 297 and closes at 58°F • Installs on or near the discharge line of the evaporator or on the suction line Loss of Charge Switch Kit • Protects the compressor from damage due low refrigerant charge conditions • SPST, normally -closed switch • Automatic reset switch • Mounted on liquid line Refrigerant Line Kits • Refrigerant lines are shipped refrigeration clean • Lines are cleaned, dried, pressurized and sealed at factory • Suction line fully insulated • Lines are stubbed at both ends COMPRESSOR 0 Scroll Compressor • High efficiency with uniform suction flow • Constant discharge flow, high volumetric efficiency and quiet operation • Low gas pulses during compression reduces operational sound levels • Compressor motor is internally protected from excessive current and temperature • Muffler in discharge line reduces operating sound levels • Compressor is installed in the unit on resilient rubber mounts for vibration free operation Scroll Compressor Operation • Two involute spiral scrolls matched together generate a series of crescent -shaped gas pockets between them • During compression, one scroll remains stationary while the other scroll orbits around it • Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates • As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced • When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls • During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle • Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency • Compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged Optional Accessories Compressor Crankcase Heater • Protects against refrigerant migration that can occur during low ambient operation Compressor Sound Cover • Reinforced vinyl compressor cover • 1-1/2 inch thick batt fiberglass insulation • All open edges are sealed with a one -inch wide hook and loop fastening tape 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 4 FEATURES CONTROLS Optional Accessories iComfort® M30 Smart Wi-Fi Thermostat • Wi-Fi-enabled, electronic 7-day, universal, multi -stage, programmable, touchscreen thermostat • 4 Heat/2 Cool • Auto -changeover • Dual -fuel control with optional outdoor sensor • Controls dehumidification during cooling mode and humidification during heating mode • Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol° control, and equipment maintenance reminders • Easy to read 4.3 in. color touchscreen (measured diagonally) • LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required) • Smooth Setback Recovery starts system early to achieve setpoint at start of program period • Compressor short -cycle protection (5 minutes) • Up to four separate schedules are available plus Schedule IQTM • One -Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away • Smart Away"" - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving • Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets • Smart home automation compatible with Amazon Alexa°, Google Assistant and IFTTT NOTE - See the iComfort° M30 Smart Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor • Used with the iComfort° M30 Smart Thermostat • Allows thermostat to display outdoor temperature NOTE - Sensor is required for the Enhanced Dehumidification Accessory (EDA). Thermostat • Thermostat is not furnished with unit • See Lennox Price Book for selection Compressor Hard Start Kit • Single-phase units are equipped with a PSC compressor motor • This type of motor normally doesn't need a potential relay and start capacitor • For conditions such as low voltage kit may be required to increase the compressor starting torque Compressor Low Ambient Cut -Off Switch • Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F Compressor Time -Off Control • Kit prevents compressor short -cycling and allows time for suction and discharge pressure to equalize • Permits compressor start-up in an unloaded condition • Automatic reset with 5 minute delay between compressor shut-off and start-up Indoor Blower Off Delay Relay • Delays the indoor blower -off time during the cooling cycle Low Ambient Kit • Air conditioners can operate down to 45°F outdoor air temperature without additional controls • Allows unit to operate properly down to 30°F NOTE - Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit. NOTE - A compressor lock -out thermostat should be added to terminate compressor operation below recommended operation conditions. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 5 FEATURES CABINET ®• Heavy -gauge steel construction • Five station metal wash process • Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil • Powder paint finish provides superior rust and corrosion protection • Control box is conveniently located with all controls factory wired • Corner patch plate allows access to compressor components • Drainage holes are provided in base section for moisture removal PermaGuardW Unit Base • Durable zinc -coated base section resists rust and corrosion © Refrigerant Line Connections, Electrical Inlets, Service Valves • Sweat connection suction and liquid lines • Located on corner of unit cabinet • Fully serviceable brass service valves • Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system • Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access • See dimension drawing Optional Accessories Unit Stand -Off Kit • Black high density polyethylene feet • Raises unit off mounting surface • Four feet furnished per order number 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 6 SPECIFICATIONS General Model No. Northern Region Data Nominal Tonnage 13ACXN018 1.5 13ACXN02413ACXN030 2 2.5 13ACXN036 3 13ACXN042 3.5 13ACXN048 4 13ACXN060 5 Connections Liquid line o.d. - in. (sweat) Suction line o.d. - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 5/8 5/8 3/4 3/4 3/4 7/8 7/8 Refrigerant (R-410A) furnished 4 lbs. 1 oz. 3 lbs. 14 oz. 5 lbs. 2 oz. 5 lbs. 4 oz. 6 lbs. 8 oz. 7 lbs. 12 oz. 9 lbs. 0 oz. RFCIV Metering Orifice Size Furnished 0.051 0.057 0.065 0.072 0.076 0.082 0.090 Outdoor Net face area Outer coil Coil sq.ft. Inner coil 11.33 11.33 13.22 13.22 16.33 18.67 16.33 --- --- --- --- --- --- 15.71 Tube diameter - in. Number of rows Fins per inch 5/16 5/16 5/16 5/16 5/16 5/16 5/16 1 1 1 1 1 1 2 26 26 26 26 26 26 22 Outdoor Diameter - in. Fan Number of blades Motor hp Cfm Rpm Watts 18 18 18 18 22 22 22 3 3 4 4 4 4 4 1/10 1/10 1/5 1/5 1/4 1/4 1/4 2350 2350 2400 2400 3500 3670 3600 1010 1010 1090 1090 825 835 830 165 165 185 185 300 295 285 Shipping Data - lbs. 1 package 138 138 144 151 188 195 218 ELECTRICAL DATA Line voltage data - 60 hz - 1 ph 2 Maximum overcurrent protection (amps) s Minimum circuit ampacity 208/230V 208/230V 208/230V 208/230V 208/230V I 208/230V 208/230V 20 25 25 35 45 50 60 12.4 14.7 17.1 22.0 28.1 31.9 34.6 Compressor Rated load amps Locked rotor amps Power factor 9.4 11.2 12.8 16.7 21.2 24.2 26.3 56.6 60.8 64 70 90 100 125 0.98 0.98 0.98 0.99 0.99 0.99 0.99 Condenser Full load amps Fan Motor Locked rotor amps 0.7 0.7 1.1 1.1 1.7 1.7 1.7 1.3 1.3 2.0 2.0 3.2 3.2 3.2 CONTROLS - ORDER SEPARATELY iComfort® M30 Smart Wi-Fi 15Z69 Thermostat Remote Outdoor Temperature X2658 Sensor OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 93M05 Compressor Copeland 1OJ42 Hard Start Kit LG 88M91 Compressor Low Ambient 45F08 Cut -Off Switch Compressor Sound Cover 18J42 Compressor Time -Off Control 47J27 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 ° Low Ambient Kit (Fan Cycling) 34M72 Refrigerant L15-26-20, L15-26-25, Line Sets L15-26-35, L15-26-50 L15-41-20, L15-41-30, L15-41-40, L15-41-50 L15-65-30, L15-65-40, L 15-65-50 Unit Stand -Off Kit 94J45 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. HACR type circuit breaker or fuse. s Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 7 DIMENSIONS - UNIT INLET AIR INLET AIR INLET 4 AIR TOP VIEW 4-3/8 4-3/8 4-3/8 (111) �Qr, ) / o \ J OPTIONAL UNIT �J / COM�� INLET STAND-OFF KIT (4) / (Field Installed) n PRESS(PR lug \ AIR COIL DRAIN OUTLETS/ (Around perimeter of base) / —SUCTION LINE (162) \ CONNECTION (162) o LIQUID LINE CONNECTION 6-3/8 4-3/8 (162) (111) TOP VIEW BASE SECTION I I I 2 (51) SIDE VIEW A OUTDOOR t DISCHARGE AIR COIL F COMPRESS SUCTION A LIQUID LI CONNECTI 0 .11 OPTIONAL UNIT SIDE VIEW STANDOFF KIT (4) (FIELD INSTALLED) Model A B C inches mm inches mm inches mm 13ACXN018 13ACXN024 13ACXN030 13ACXN036 13ACXN042 13ACXN048 13ACXN060 24-1/4 616 25-1/4 641 24-1/4 616 24-1/4 616 25-1/4 641 24-1/4 616 24-1/4 616 29-1/4 743 28-1/2 724 24-1/4 616 29-1/4 743 28-1/2 724 28-1/4 718 29-1/4 743 28-1/2 724 28-1/4 718 33-1/4 845 32-1/2 826 28-1/4 718 29-1/4 743 28-1/2 724 4-3/8 (111) 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 8 SOUND DATA 1 Unit Model Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - HZ 1 Sound Rating Number (dBA) 2 Estimated Sound Pressure Level at Distance From Unit (dBA at distance in ft.) 125 250 500 1000 2000 4000 8000 3 5 10 15 50 018 53 60 64.5 68.5 67 61.5 54.5 76 69 64 58 55 44 024 51.5 62 64.5 68.5 67 60.5 53.5 76 69 64 58 55 44 030 52.5 62 67.5 69 67 61.5 54.5 76 69 64 58 55 44 036 52.5 61 67 69 67 61.5 52.5 76 69 64 58 55 44 042 58 68 73.5 75.5 74 69.5 62.5 79 72 67 61 58 47 048 57.5 67 73 74.5 71 64 58.5 79 72 67 61 58 47 060 57 63 69.5 71.5 71 65.5 60.5 79 72 67 61 58 47 NOTE - the octave sound power data does not include tonal correction. Tested according to AHRI Standard 270-2008 test conditions. 2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. FIELD WIRING DISCONNECT t SWITCH —(By Others) LENNOX AIR CONDITIONER r r DI THERMOSTAT I SWITCH CT (Required) (By Others) t------� t------J LENNOX HEATING UNIT OR AIR HANDLER UNIT A - Two Wire Power B - Two Wire Power (See Electrical Data) C - Two Wire Low Voltage (18 ga. minimum) D - Four Wire Low Voltage (Electro-Mechanical) 18 ga. minimum. Five Wire Low Voltage (Electronic) 18 ga. minimum NOTE - Field Wiring Not Furnished All wiring must conform to NEC or CEC and local electrical codes. INSTALLATION CLEARANCE F See NOTE See NOTES *1 _ .JL v See NOTES BOX / NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 9 TXV/ORIFICE USAGE Use this table for C35, CH23, CH35 and CR33 Field Installed TXV/Orifice Match -Ups Outdoor Unit Refrigerant Metering Orifice (RFC) Thermal Expansion Valve (TXV) Order No. Orifice Size 018 1OW92 0.050 0.057 112.118 12J18 024 97M75 030 1OW99 0.065 112.118 036 1OW85 0.072 12J19 042 97M78 0.076 112.120 048 97M79 0.082 112.120 060 10M13 0.090 12J20 CX35 and CHX35 coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the 7XV SUBSTITUTIONS' table by size. The correct TXV must be ordered separately and Feld installed. C35 and CH35 coils - Use the RFC orifice shipped with the outdoor unit or replace the factory installed RFC orifice with the expansion valve listed. CR33 and CH23 coils - Use the RFC orifice shipped with the outdoor unit or use the expansion valve listed. TXV SUBSTITUTION A general guide for replacing the factory installed TXV if the indoor unit (coil/air handler) is larger than the outdoor unit. Outdoor Unit IIndoor Unit TXV Furnished TXV Replacement Size Tons Size Tons 024 2 38 3.5 12J19 12J18 024 2 42 3.5 12J20 12J18 024 2 48 4 12J20 12J18 024 2 49 4 12J20 12J18 030 2.5 38 3.5 12J19 12J18 030 2.5 42 3.5 12J20 12J18 030 2.5 43 3.5 12J20 12J18 030 2.5 44/48 4 12J20 12J18 030 2.5 48 4 12J20 12J18 030 2.5 50/60 4 12J20 12J18 TXV Ranges: 12.118 - 1.5 to 2.5 ton systems - Use on 2.5 ton and lower systems. 12J19 - 3 ton systems - Use down to 2 ton systems. 12.120 - 3.5 to 5 ton systems - Use down to 3 ton systems. AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air -circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. 13ACXN - 1.5 to 5 Ton Air Conditioner / Page 10 REVISIONS Sections Approvals and Warranty LE--7 NNOX Description of Change Corrected compressor warranty. 0 A ©40HMI ,/MEMBER COMPANY �M C us ntertek Visit us at www.lennox.com For the latest technical information, www.LennoxPros.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2020 Lennox Industries, Inc.