FIR2022-0013_Fire_Sprinkler_Equipment_Specification_Sheets_2.8.2022_9.41.22_PM_2670039
Patty's Egg Nest T.I. 21940 Hwy 99, Suite B Edmonds WA 98026 FIRE SPRINKLER PRODUCT SUBMITTAL DATA Emerald Fire 11021 Cramer Road NW Gig Harbor, WA 98329 Phone: 253-857-2056 — Fax: 253-857-2312 Patty's Egg Nest T.I. 21940 Hwy 99, Suite B Edmonds WA 98026 FIRE SPRINKLER PRODUCT SUBMITTAL DATA 1. Viking VK302 QR'/2" 155* K=5.6 Chrome Recessed Pendent Sprinkler 2. Victaulic Vic -Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 3. Wheatland Pipe Company Schedule 40 Black Pipe (I") 4. Anvil International Black Cast Iron Threaded Fittings (1") 5. Sammy Screws Wood Sidewinders Model SWG 20 Page 1 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking MicrofaW Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and tem- perature ratings to meet design requirements. The special Polyesterand Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV M. FM Approved: Class Series 2000 vds VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 LPC6. LPCB Approved: Certificate 096e/06 WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov C E CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-SO021 China Approval: Approved according to China GB standard Q MED Certified: Standard EN 12259-1, EC -certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric—) Glass -bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) `Wl_us Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). Approvals ONLY is 5 psi (0.35 bar). The minimum operating pressure for LPCB and CE Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring -Exposed For ENT Coated Sprinklers: Belleville Spring -Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Phrome = F, W _ - , Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 1155 °F (68 °C) = B, 1175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Form No. F_033314 19.11.14 Rev 19.3 Replaces Form No. F_033314 Rev 19.2 (Revised China Approval; removed 19780) Page 2 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B. B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast° Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. x Wrench Flat Protective Sprinkler Cap 21475 • Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 19.11.14 Rev 19.3 Page 3 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion -Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 19.11.14 Rev 19.3 Page 4 of 6 ® MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) Temperature KEY The Viking Microfase Quick Response Finish Pendent Sprinkler VK302 A1XFEscutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Thread Size Nominal Overall Listings and Approvals' Part SIN Sprinkler K-Factor Length (Refer also to Design Criteria.) StyleNPT Number BSP U.S. metricz Inches mm cULus' VdS LPCB C E 7 e China Approval 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y D1 213549 VK302 Pendent 15 mm 5.6 80.6 2-1/4 58 1 D3 D3 NOTICEOffice) 06662E VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1X, B1Y Al A1X, B1Y D1X, C1Y7 D1 Approved Te gs es ApprM., Approved Escutcheons A- 135 °F (57 °C), 55 °F (68 °C) 175 °F 1 - Brass,hite X - Standard surface -mounted escutcheon or the (79 °C), 200 °F (93 °C) Polyester,,yes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F ter5,6 Y - Standard surface -mounted escutcheon or recessed with the Viking Micromatic® (79 °C), and 200 °F (93 °C) 2 - ENT' Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 °F (68 °C), 175 °F (79 °C), and 3 - Chrome Z - Standard surface -mounted escutcheon 200 °F (93 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion -resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC -certificate of constancy of performance 0832-CPR-S0021. s MED Certified, Standard EN 12259-1, EC-0832-MED-1003. s Approved according to China GB Standard. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Reguirements: The Viking Microfast° Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.11.14 Rev 19.3 Page 5 of 6 ® MICROFAST° QUICK 4 I KjRESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast° Quick Response Finish Pendent Sprinkler VK302 AlX4- Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metricz Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 213541 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 C3 NOTICE.. Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A- 135 OF (57 °C), 155 OF (68 -C), 175 OF (79 -C), 200 OF Approved Finishes X - Standard surface -mounted escutcheon or the (93 °C), 286 OF (141 -C) OF -C), OF °C), OF °C), 1 -Brass, Chrome, White Polyester", Viking Micromati&Model E-1 Recessed Escutcheon B - 135 (57 155 (68 175 (79 and and Black Polyester' Y - Standard surface -mounted escutcheon or recessed 200 OF (93 -C) OF -C), OF -C), OF -C), 2 - ENT5 with the Viking Micromati& Model E-1 or E-2 C - 155 (68 175 (79 200 (93 286 3 - Chrome Recessed Escutcheon OF (141 -C) Z - Standard surface -mounted escutcheon D - 155 OF (68 -C), 175 OF (79 -C), 200 OF (93 -C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. z Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. 5 Approved according to China GB Standard. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non -storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.11.14 Rev 19.3 Page 6 of 6 ® MICROFAST° QUICK RESPONSE PENDENT N4 I Ki SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum " 2-1/2" (64 mm) maximum (15 mm) NPT` � _ c • kh kid T 2-1/4" 1-3/4" (57 mm)) (45 mm) _, Installed with a standard 1/8" surface -mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon 2-1/8" 2-1/8" y� (54 mm) (54 mm) 1-1 /8" IT 1-3/4" (29 mm) 2"" t (45 mm) Min. (51 mm) Max. Max. Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread -on Recessed Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1 /8" (29 mm) Min. Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.11.14 Rev 19.3 Replaces Form No. F_033314 Rev 19.2 (Revised China Approval; removed 19780) Victaulic° Vic-FlexTm Sprinkler Fittings Series AH2 Braided Flexible Hose FIexTM 1.0 PRODUCT DESCRIPTION ✓ctaulic° 10.85 Available Sizes by Component • Series AH2 Braided Hose: 31, 36, 48, 60, 72"/790, 914, 1220, 1525, 1830mm. Note: length includes adapter nipple and 5.75/140mm straight reducer. • Sprinkler Reducers: 1/2" and 3/4/15 and 20 mm sprinkler connections and 5.75/140 mm, 97230 mm, 137330 mm straight lengths and short, long 900 elbows. Note: The short 90' elbow is typically used with concealed sprinklers while the long 90' elbow is typically used in the installation of recessed pendent sprinklers. • Adapter Nipples: 1725 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. 3/4Y20 mm NPT or BSPT available for VdS. 11/a"/ 32mm BSPT available for LPCB. • Brackets: • Style AB1 for suspended and hard -lid ceilings, allows installation before most ceiling tiles in place �• Style A132 for suspended and hard -lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style A133 for surface mount applications, wood, metal and block walls • Style AB4 for hard -lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style A137 for suspended and hard -lid ceilings • Style A137 Adjustable for suspended and hard -lid ceilings • Style A138 for hard -lid ceilings with CD 60/27 profile metal studs (regionally available) • Style A139 for hard -lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong® TechZoneTM ceilings Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Submitted By Date virtai dir_rnm Spec Section Paragraph Approved Date 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. 1 detaul- victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) Connections • To adapter nipple (inlet) via 1'725.4 mm NPT or BSPT male thread OR • To adapter nipple (inlet) via 3/4720 mm BSPT male thread(VdS only) • To sprinkler head (outlet) via 1h" or 3/4715 mm or 20 mm Minimum Bend Radius • 77178 mm (FM Approval) • 2751 mm (cULus Listed) • 3776.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (1/2715mm reducer) K5.6/8,1 (S.I.), (3/4720mm reducer) K14.0/20,2 (S.I.) • cULus (1/2715mm reducer) K8.0/11,5 (S.I.), (3/4720mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2715mm reducer) K5.6/8,1 (S.I.), (3/4720mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS F c( eo- UdS LPCB 3.0 SPECIFICATIONS — MATERIAL Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2 or 3/4"): Carbon Steel, Zinc -Plated Brackets: Carbon Steel, Zinc -Plated 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 2 ✓ctaul,c� victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose 5 1 6 y7 3 4 A r< B Hose Length Dimensions Hose Length inches mm A inches mm B inches mm 31/790 25.25/641 31/790 36/915 31.25/794 36/915 48/1220 42.25/1073 48/1220 60/1525 54.25/13,78 72/1830 66.25/1683 60/1525 72/1830 Standard Reducer 5.757140 mm straight reducer Optional Reducers 9.0Y229 mm straight reducer 13.07330 mm straight reducer 2.6T7 66.5 m m 4.837 122.7 mm Short 90' elbow reducer 2.627 66.5 mm 6.5P7 166.9 mm Long 90° elbow reducer Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid 7 Collar/Weld Fitting 8 Sleeve NOTE • The Short 90' elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 3 ✓Ctsuliid victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB1 • Suspended Ceilings • Hard -Lid Ceilings (FM Only) Item Description 1 24"/610 mm or 48'71220 mm Square Bar* 2 Patented Center Bracket 3 End Bracket 'Both sizes FM/VdS/LPCB approved, cULus listed Style AB2 • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 24'7610 mm or 48'71220 mm Square Bar* 2 Patent -Pending adjustable Center bracket 3 End Bracket `Both sizes FM/VdS/LPCB approved, cULus listed Style AB3 • Surface Mount Applications • FM Approved 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 4 ✓Ctsuliid victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 • Hard -Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1220 mm Square Bar* 2 Patent -Pending adjustable Center bracket 3 End Bracket for Hat Furring Channel `Both sizes FM/VdS approved, cULus listed Style AB7 • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 24"/610 mm or 48"/1220 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket 'Both sizes FM/VdS approved. Style A137 Adjustable • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) *Both sizes FM/VdS approved. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctsuliid victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB8 • Hard -Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar* 2 Patent -pending adjustable center bracket 3 *Both sizes FMNdS "Both sizes FM/VdS approved. Style AB9 • Hard -Lid ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1220 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket for Hat Furring Channel "Both sizes FM/VdS approved. Style AB10 • Suspended ceilings • Armstrong® TechZoneTM Item Description 1 6"/152 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket 'FM/VdS approved, cULus listed. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 6 ✓Ctsuliid virtaidir rnm 4.4 DIMENSIONS CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB1 Bracket Suspended Ceiling Grid with Recessed Sprinkler \ R See ch rt See Chart '✓ Bracket a—rnbly e ABl 2°/d"/50 mm 4.4'/ max. hole 113 mm 2751 mm min. hole tc 4mmTypical ceiling grid shed g face 247510 mm 0r 4871219 mm on Center V2707 3/4'719mm Max. Recess Hose Clearance Chart Dimension inches inches inches inches inches inches mm mm mm mm mm mm R Minimum 2 3 4 5 6 7 Bend Radius 50 80 100 125 EL50 175 A Min. 10.75 11.75 12.75 13.75 14.75 15.75 273 298.5 324 349 375 400 Suspended Ceiling Grid with Recessed Sprinkler with 90' Elbow (Long) f V2707 3/4719mm Max. Recess Hose Clearance Chart Dimension inches mm A Suspended Ceiling Grid with Concealed Sprinkler V3802 1/2'Y12.7mm Max. Recess Hose Clearance Chart Dimension inches inches inches inches inches inches mm mm mm mm mm mm R Minimum 2 9F 3 4 5 6 7 Bend Radius 50 80 100 125 150 175 A Min. 10.1 11.1 12.1 13.1 14.1 15.1 269 281 307 333 358 383 Suspended Ceiling Grid with Concealed Sprinkler with 90' Elbow (Short) V3802 V2712.7mm Max. Recess Hose Clearance Chart Dimension inches mm A 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 7 ✓Ctsuliid victaulic.com 4.4 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB2 Bracket Hard -lid Ceiling with Concealed Sprinkler Hard -lid Ceiling with Recessed Sprinkler G�=1 W 1'ni V3802 ih°/12.7mm Max. Recess Hose Clearance Chart Dimension inches inches inches inches inches inches mm mm mm mm mm mm R Minimum 2 3 4 5 6 7 Bend Radius 50 80 100 125 150 175 A Min. 7.63 8.63 9.63 10.63 11.63 12.63 193 218 244 269 295 320 See chart V2707 3/4719mm Max. Recess Hose Clearance Chart Dimension inches inches inches inches inches inches mm mm mm mm mm mm R Minimum 2 3 4 5 6 7 Bend Radius 50 80 100 125 150 175 A Min. 6.13 7.13 8.13 9.13 10.13 11.13 155 180 206 231 256 282 NOTE ° Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. Hard -lid Ceiling Grid with Concealed Sprinkler with 90° Elbow (Short) V3802'h"/12.7mm Max. Recess Hard -lid Ceiling with Recessed Sprinkler with 90° Elbow (Long) Stm V2707 3/4°/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches mm mm A Min. 127 A Min. 3.6391 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 8 ✓Ctsuliid victaulic.com 4.5 DIMENSIONS CLEARANCES WITHIN SIDEWALL Series AH2 Braided Hose and Style AB2 Bracket Horizontal Sidewall Sprinkler V2707 3/4"/19mm Max. Recess Hose Clearance Chart Dimension inches inches inches inches inches inches mm mm mm mm mm mm R Minimum 2 3 6 7 Bend Radius 50 80 +139.13 150 175 A Min. 6.13 7.13 10.13 11.13 256 282 Horizontal Sidewall Sprinkler with 90' Elbow (Long) V2707 3/4"/19mm Max. Recess Hose Clearance Chart Dimension inches mm A 3.63 91 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 9 ✓Ctsuliid victaulic.com 4.6 DIMENSIONS CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB4 Bracket Hat Furring Channel Grid with Recessed Sprinkler V2707 3/4"/19mm Max. Recess Hose Clearance Chart Dimension inches inches inches inches inches inches mm mm mm mm mm mm R Minimum 2 3 4 5 6 7 Bend Radius 50 80 100 125 150 175 A Min. 10.3 11.3 12.3 13.3 14.3 15.3 262 287 313 338 363.5 389 Hat Furring Channel Grid with Recessed Sprinkler with Hat Furring Channel Grid with Concealed Sprinkler with 90' Elbow (Long) 90' Elbow (Short) Chart 2'/.a/60 mm m .hole 2"/51 mm i i i i in. Mole yplcal ceiling the i n�,ned See note) celFn9 Typical 16/406 mm Typical ceiling grid . 1610 mm on Center V2707 3/4719mm Max. Recess Hose Clearance Chart Dimension inches mm 8 200 ♦111�,111 ,I<♦Ir ' ,Il♦I, V2707 3/4719mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 5.9 149 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 10 ✓ctsuliic' victaulic.com 4.6 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB3 Bracket Surface Mount Application with Recessed Sprinkler 2751 mm min. hole Hose Clearances Wall Thickness W. 2 4 6 8 10 2 4 6 8 10 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 5.75 9 13 5.75 9 13 9 13 13 13 „B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 Hose 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 Clearance "C" 294 376 478 1 243 325 427 1 275 376 1 325 1 275 1 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 "R" 175 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. • See installation instructions for mounting screw type and size. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 11 ✓ctsuliic' victaulic.com 5.0 PERFORMANCE — FRICTION LOSS DATA c&US Series AH2 Braided Hose with Straight 5.75" Reducers LISTED Style AB1, AB2, AB4, and AB10 Brackets Series AH2 Hose Maximum Length of Equivalent Length Number of Stainless Steel of 1733.7 mm 90' Bends at 2751 mm Flexible Hose Outlet Size Sch. 40 Pipe (C=120) Bend Radius inches/mm inches/mm/type feet/meters 31/775 '/2'715/Straight 16/4.9 4 3/4"/20/Strai ht 17/5.2 4 >36/900 '/2'715/Straight 21/6.4 5 3/4"/20/Strai ht 23/7.0 5 -�48/1200 '/2'715/Straight 32/9.8 8 3/4"/20/Strai ht 37/11.3 8 60/1500 '/2'715/Straight 3/4"/20/Strai ht 46/14.0 10 46/14.0 10 55/16.8 12 72/1800 '/z"/15/Straight 3/4"/20/Straight 53/16.2 12 Series AH2 Braided Hose Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2751 mm center line bend radius Length of Stainless Steel Flexible Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Hose Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches/ inches/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ mm mm meters meters meters meters meters meters meters meters meters meters meters meters 1/2 715 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 N.A N.A N.A N.A N.A N.A N.A N.A 31 /775 3/4720 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2 N.A N.A N. N.A N.A N.A N.A N.A 1/2 715 13.5/4.1 16.0/4.9 18.0/5.5 19.0/5.8 21.0/6.4 N.A N. N.A N.A N.A N.A N.A 36/900 3/4" /20 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A 1/2 /15 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A 418/1200 3/4720 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 30.0/9.1 37.0/11.3 N.A N.A N.A N.A 1/2 /15 21.5/6.6 24.0/7.3 27.0/8.2 28.5/8.7 30.0/9.1 31.0/9.4 37.0/11.3 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 60/1500 3/4720 23.0/7.0 24.0/7.3 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 1/2 /15 30.0/9.1 32.0/9.8 36.5/11.1 37.5/11.4 40.5/12.5 41.0/12.8 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/16.8 72/1800 3/4720 32.0/9.8 32.5/9.9 35.0/10.7 35.5/10.8 40.0/12.3 40.5/12.3 41.0/12.5 46.0/14.0 50.0/15.2 51.0/15.5 52.0/15.8 53.0/16.2 NOTES: • Values for use with 5.75" straight reducers. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 12 ✓ctsuliic' victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA Series AH2 Braided Hose FM Style AB1, ® AB3, AB4, AB7, AB7 Adj., AB8, AB9 and AB10 VicFlex Brackets Length of Stainless Steel Flexible Hose inches/mm K-Factor Imperial/S.I. Outlet Size inches/mm/type Series AH2 Hose Maximum Number of 90' Bends at 7/178mm Bend Radius Equivalent Length of 1"/33.7mm Sch. 40 Pipe feet/meters 31/775 5.6/8.1 '/2"/15/Straight 23.5/7.1 2 2 '/2715/90' Elbow 23/7.0 36/900 5.6/8.1 '/2"/15/Straight 27.8/8.5 '/2'715/90' Elbow 27.7/8.4 48/1200 5.6/8.110E— /2 '"/15/Straight 38.2/11.6 3 '/2'715/90' Elbow 37.4/11.4 60/1500 5.6/8.1 '/2"/15/Straight 42.4/12.9 4 1/2'715/90' Elbow 43/13.1 72/1800 5.6/8.1 '/2"/15/Straight 46.6/14.2 4 '/2715/90' Elbow 48.5/14.7 31/775 8.0/11.5 3/4"/20/Strai ht 20.7/6.3 2 3/4"/20/90° Elbow 20.5/6.2 36/900 8.0/11.5 3/4"/20/Strai ht 25.0/7.6 2 3/4"/20/90" Elbow 24.6/7.5 �48/1200 8.0/11.5 3/4"/20/Strai ht 35.5/10.8 3 3/4"/20/90° Elbow 34.7/10.6 60/1500 8.0/11.5 3/4"/20/Strai ht 39.6/12.1 4 3/4"/20/90° Elbow 40.1/12.2 72/1800 8.0/11.5 3/4"/20/Strai ht 43.5/13.2 4 3/4"/20/90° Elbow 45.2/13.7 31/775 11.2/16.1 3/4"/20/Strai ht 17.8/5.4 2 3/4"/20/90" Elbow 18/5.5 36/900 11.2/16.1 3/4"/20/Strai ht 22.2/6.7 2 3/4"/20/90° Elbow 22.1/6.7 48/1200 11.2/16.1 3/4"/20/Strai ht 32.9/10.0 3 3/4"/20/90° Elbow 32.1/9.8 60/1500 11.2/16.1 3/4"/20/Strai ht 36.8/11.2 4 3/4"/20/90" Elbow 37.1/11.3 72/1800 11.2/16.1 3/4"/20/Strai ht 40.5/12.3 4 3/4"/20/90° Elbow 41.9/12.7 31/775 14.0/20.2 3/4"/20/Strai ht 14.9/4.5 2 3/4"/20/90" Elbow 15.5/4.72 36/900 14.0/20.2 3/4"/20/Strai ht 19.4/5.9 2 3/4"/20/90° Elbow 19.6/5.9 48/1200 14.0/20.2 14.0/20.2 3/4"/20/Strai ht 30.3/9.2 3 3/4"/20/90" Elbow 29.5/8.9 60/1500 3/4"/20/Strai ht 33.9/10.3 4 3/4"/20/90° Elbow 34.1/10.4 72/1800 14.0/20.2 3/4"/20/Strai ht 37.5/11.4 4 3/4"/20/90" Elbow 38.6/11.7 FM NOTES: • Series AH2 has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods, per FM 1637 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE: A 48-inch hose installed with two 30' bends and two 90' bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 13 ✓ctsuliid victaulic.com 5.2 PERFORMANCE — FRICTION LOSS DATA vds Series AH2 Braided Hose Style AB1, ® AB4, AB7, AB7 Adj., AB8, AB9, and AB1O Brackets Series AH2 Hose Equivalent Length of Maximum Number Length of steel pipe according to of 90' Bends at Stainless Steel Outlet EN 10255 ON 25 3"/76.2mm Bend Flexible Hose Size (33,7 x 3,25) Radius mm/inches mm/inches type meters/feet meters/feet 15mm/'/2"/Strai ht 20 mm/3/4"/Strai ht 5.5/18.0 900/36 15mm/'/2"/Strai ht 6.4/21.0 3 20 mm/3/4"/Strai ht —> 1200/48 15mm/'/2"/ Straight 8 5/27 9 20 mm/3/4"/Strai ht 15mm/'/2"/Strai ht 1500/60 10.7/35.1 4 20 mm/3/4"/Straight 15mm/'/2"/Strai ht 1800/72 12.8/42.0 4 20 mm/3/4"/Strai ht VDS CEILING MANUFACTURERS LIST AB1,FA—B-21 A137, AB10 A134/9 AB8 1. AMF No specific approval 1. Hilti 2. Armstrong 2. Knauf 3. Chicago Metallic 3. Lafarge 4. Dipling 4. Lindner 5. Durlum 5. Rigips 6. Geipel 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn LPCB Series AH2 Braided Hose Style AB1 Bracket Series AH2 Hose Length of Equivalent Length Maximum Stainless of steel pipe Number of Steel according to 90' Bends at Flexible Outlet EN 10255 ON 25 3'776.2mm Hose Size (33,7 x 3,25) Bend Radius mm/inches I mm/inches/type meters/feet 15mm/l/2"/Strai ht 775/31 1.8/6.0 2 20 mm/3/4"/Strai ht 15mm/l/2"/Strai ht 900/36 3.6/11.9 3 20 mm/3/4"/Straight 15mm/l/2"/Strai ht 1200/48 4.3/14.0 3 20 mm/3/4"/Strai ht 15mm/l/2"/Straight 1500/60 4. it 13.6 3 20 mm/3/4"/Straight 15mm/l/2"/Strai ht 1800/72 5.5/18.1 3 20 mm/3/4"/Strai ht Series AH2 Hose Length of Equivalent Length Maximum Stainless of steel pipe Number of Steel according to 90' Bends at Flexible Outlet EN 10255 ON 25 3'776.2mm Hose Size (33,7 x 3,25) Bend Radius mm/inches mm/inches/type meters/feet 15mm/l/2"/90° Elbow 775/31 1.3/4.3 2 20 mm/3/4"/90° Elbow 15mm/1/2790° Elbow 900/36 2.8/9.1 3 20 mm/3/4"/90° Elbow 15mm/l/2"/90°Elbow 1200/48 4.1/13.4 3 20 mm/3/4790° Elbow 15mm/l/2"/90° Elbow 1500/60 4.6/15.2 3 20 mm/3/4"/90° Elbow 15mm/l/2790° Elbow 1800/72 5.3/17.4 20 mm/3/4"/90° Elbow 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 14 ✓ctsulic" victaulic.com 6.0 NOTIFICATIONS A WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 7.0 REFERENCE MATERIALS — CHARACTERISTICS Flexible Hose In -Plane Bend Characteristics One Bend I - \ I I \ I I Minimum I I bend radius I < 90° I I --L— Two Bends Three Bends ff 2X ZX Minimum Minimum Minimum bend radius ( bend radius bend radius OR OR Minimum bend radius Minimum Minimum I ( bend radius bend radius I Minimum be radius ,�, - Minimum I bend radius NOTE • For out -of -plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to -VICFLEX-AB1-AB2-AB10, -VICFLEX-AB4-AB9, I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.85 5839 Rev X Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 15 ✓ctauliic° Wheatland's Schedule 40 Sprinkler Pipe Wheatland's Schedule 40 Sprinkler Pipe is a high quality sprinkler pipe offering you the full range of assurances you require. Schedule 40 Sprinkler Pipe has passed some of the toughest lab tests ever created for sprinkler pipe. Made in the U.S.A. by Wheatland Tube Company means made to the highest standards for consistant quality. Wheatland's schedule 40 Sprinkler Pipe is made from the highest quality steel in one of the nation's most modern and most complete pipe manufacturing plants. Our proprietary mill coating offers you a clean, corrosion and heat resistant surface that outlasts and outperforms standard lacquer coatings. Plus, this coating can be quickly and easily painted without special preparation. Or it may be hot -dipped galvanized to meet FM requirements for dry systems in accordance with the zinc coating specification of ASTM A795. Schedule 40 is also available as ASTM A 53 Type F, Grade A in NPS 1 - 6 and is UL Listed and FM Approved. Specifications and Approvals Wheatland's Schedule 40 Standard Wall Sprinkler Pipe meets or exceeds the following: • UL Listed • FM Approved • ASTM A795, Type E, Grade A Please refer to appropriate documentation for up-to-date listing and approval information. Specifications and descriptions are accurate as known at time of publication and are subject to change without notice. Specifications NPS Nominal O.D Nominal I.D Nominal Wall Nominal Weight UL CRR Pieces Lift in. mm in. mm in. mm lbs./ft. kg/m 1 " 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1 1 /4" 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1 1 /2" 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2" 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Schedule 40 steel pipe is used as the benchmark (value of 1.0). l Wheatland Tube Company Council Avenue, P.O. Box 608 Wheatland, PA 16161-0608 Ph 800.257.8182 Fax 724.346.7260 www.wheatiand.com 0207 1.Wrev01 Anvil standard and extra heavy cast iron threaded fittings are manufactured in accordance with ASME-B16.4 (except plugs and bushings, ASME B16.14). Dimensions also conform to Federal Specifications, WW-P-501 (except plugs and bushings WW-P-471). C U` us FM APPROVED For Listings/Approval Details and Limitations, visit our website Q www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative Cast Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 125 Class 250 (°F) (10 psi bar psi bar -200 to 1500 -28.9 to 65.6 175 12.1 400 27.6 2000 93.3 165 11.4 370 25.5 2500 121.1 150 10.3 340 23.4 3000 148.9 140 9.7 310 21.4 3500 176.7 125 8.6 300 20.7 4000 204.4 — — 250 17.2 Z ANVIL PF-9.09 iIII CAST IRON IIIIII Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 351 90° Elbow Size A B Unit Weight Black -- BA .a �-B �A->I - ----------r------ '- - 'Lj NIPS DN in mm in mm Ibs k 1/4 8 1/2 13 13/16 22 0.16 0.07 3/8 10 '/16 14 15/16 24 0.25 0.11 1/2 15 11/16 17 11/8 29 0.40 0.18 3/4 20 1a/16 22 11'/16 33 0.60 0.27 1 25 15/16 24 11/2 38 0.92 0.42 11/4 32 11/8 29 1'A 44 1.44 0.65 11/2 40 15/16 33 115/16 49 1.95 0.88 2 50 19/16 40 21/4 57 3.13 1.42 21/2 65 113/16 47 211/16 68 4.94 2.24 3 80 23/16 56 31/8 79 7.21 3.27 31/2 90 27/16 62 37/16 87 9.67 4.39 4 100 211/16 68 313/16 98 12.17 5.52 5 125 35/16 84 41 /2 114 21.46 9.73 6 150 31/8 98 51/8 130 31.33 14.21 8 200 53/16 132 69h 6 167 64.56 29.28 FIGURE 371 90' Elbow, Flange & Screw Size A B Unit Black NIPS DN in mm in mm Ibs k -------- B -- -r------ '- - 21/2 65 113/16 211/6 68 10.22 4.63 23/e 56 31/3 79 13.25 6.01 4 100 211/,s 68 313/s 98 21.56 9.78 6 150 37/s 98 51/s 130 40.50 18.37 Mominal Pipe Sizes of 4'r100 DN) and larger have two holes tapped for stud or tap bolts. Note: See page 37 for pressure -temperature ratings. PF-9.09 Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 358 Tee Size A B Unit Weight Black -B-�I�-B-� A-fA -- - ---+----- - -- _ A l - -- ----' - NPS DN in mm in mm Ibs k 1/4 8 1/2 13 13/16 22 0.22 0.10 3/6 10 5/6 16 1 25 0.35 0.16 1/2 15 "/16 17 11/6 29 0.56 0.25 3/4 20 13/16 22 15/16 33 0.84 0.38 1 25 15/16 24 11/2 38 1.25 0.57 11/4 32 11/8 29 13/4 44 2.03 0.92 11/2 40 15/16 33 115/16 49 2.70 1.22 2 50 19/16 40 21/4 57 4.23 1.92 21/2 65 113/16 47 211h6 68 6.67 3.02 3 80 23/16 56 31/6 79 10.00 4.54 31/2 90 27/16 62 37/16 87 13.29 6.03 4 100 211/16 68 33/4 95 16.33 7.41 5 125 3'/16 84 41 /2 114 27.33 12.39 1 6 150 37/6 98 51/6 130 40.85 18.53 8 200 53/16 132 6'/16 167 79.00 35.83 FIGURE 359 Tee Reducing q1 -D. E I }-j-----T- f C1 1 F Size A B C D E F Unit Weight Black NPS DN NPS DN NPS DN in mm in mm in mm in mm in mm in mm Ibs k '/2 15 1/2 15 1/4 3/8 3/4 1 8 10 20 25 11/16 11/16 13/16 1 17 17 22 25 11/16 11/16 "/16 1 17 17 22 25 13/16 3/4 "/16 13/16 22 19 17 22 11/8 11/8 11/4 17/16 29 29 32 37 11/8 29 11/8 29 11/4 32 17/16 37 11/8 11/8 ' 3/16 13/8 29 29 22 35 0.57 0.26 0.57 0.26 0.68 0.31 1.00 0.45 1/4 8 3A 20 13/16 22 15/16 24 13/16 22 16/16 24 11/4 32 16/16 24 0.79 0.36 1/2 15 1/2 3/4 15 20 11/16 13/16 17 22 11/16 13/16 17 22 13/16 13/16 22 22 13/16 15/16 22 24 11/8 29 11/4 32 11/4 15/16 32 24 0.64 0.29 0.75 0.34 '/4 20 3/a 20 1/4 3/8 1/2 1 8 10 15 25 9/16 11/16 11/16 15/16 14 17 17 24 '/16 11/16 11/16 16/16 14 17 17 24 7/8 "/16 13/16 13/16 22 24 22 22 "/16 13/16 13/16 17/16 17 22 22 37 "/16 17 13/16 22 13/16 22 17/16 37 13/16 11/4 11/4 13/8 22 32 32 35 0.62 0.28 0.75 0.34 0.76 0.34 0.99 0.45 1/4 8 1 25 15/16 24 15/16 24 16/16 24 11/2 38 11/4 32 11/2 38 1.08 0.49 1/2 15 1/2 3A 1 15 20 25 11/16 13/16 15/16 17 22 24 3/4 ' 3/16 16/16 19 22 24 'S/16 "/16 15/16 24 24 24 11/4 13/8 11/2 32 35 38 13/16 22 11/4 32 13/6 35 13/8 17/16 11/2 35 37 38 0.90 0.41 0.91 0.41 1.08 0.49 1 25 3/4 20 1/2 3/4 1 15 20 25 11/16 13/16 15/16 17 22 24 11/16 13/16 'S/16 17 22 24 15/16 15/16 '5/16 24 24 24 11/4 13/8 11/2 32 35 38 13/16 22 15/16 24 17/16 37 13/8 17/16 1 11/2 35 37 38 0.89 0.40 1.00 0.45 1.13 0.51 1 25 1/4 1/2 3/4 11/4 1'/2 2 8 15 20 32 40 50 11/16 11/16 13/16 11/8 11/4 1'/16 17 17 22 29 32 37 11/16 11/16 13/16 11/8 1'/4 1'/16 17 17 22 29 32 37 11/8 15/16 15/16 16/16 1 1 29 24 24 24 25 25 11/8 11/4 13/8 111/16 113/16 2 29 32 35 43 47 50 11/4 32 11/4 32 13/8 35 111/16 43 11'/16 47 2 50 13/8 13/8 17/16 19/16 15/8 13A 35 35 37 40 41 44 1.01 0.46 1.01 0.46 1.11 0.50 1.49 0.68 1.84 0.83 2.70 1.22 Note: See page 37 for pressure -temperature ratings. Continued on next page. Z ANVIL PF-9.09 Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 367 Concentric Reducer EBA -- _ -- Size A B Unit Weight Black NIPS DN NPS DN in mm in mm Ibs k 3/4 20 V2 15 5/8 16 1Vhe 40 0.40 0.18 1 25 1/2 (Hex) 3/4 (Hex) 15 20 11/15 '/16 17 11 111/15 1 V2 43 38 0.54 0.24 0.63 0.29 11/4 32 1/2 3/4 1 15 20 25 s/15 1 15/15 14 25 24 15/8 21/8 21/8 41 54 54 0.84 0.38 0.90 0.41 1.07 0.49 1'/2 40 1/2 3/4 1 1'/4 15 20 25 32 1/2 1/2 1/2 1 13 13 13 25 15/8 15/8 13/4 21/4 41 41 44 57 1.00 0.45 1.20 0.54 1.50 0.68 1.45 0.66 2 50 1/2 3/4 1 11/4 1V2 15 20 25 32 40 5/8 3/4 3/4 13/15 7/8 16 19 19 22 22 2 2 2 21/8 2V16 51 51 51 54 56 2.00 0.91 1.90 0.86 1.83 0.83 1.78 0.81 1.98 0.90 2'/2 65 11/2 2 40 50 3/4 1 19 25 2 2'/15 51 65 3.10 1.41 2.98 1.35 3 80 3A 2 21/2 20 50 65 15/16 11/1e 15/16 24 27 24 21/2 23/4 213/1e 64 70 73 4.31 1.95 3.96 1.80 4.40 2.00 4 100 2 21/2 3 50 65 80 13/16 1V16 11/16 30 30 27 21'/1e 31/8 31/8 75 79 79 6.50 2.95 7.78 3.53 7.01 3.18 5 125 4 100 11/16 27 35/16 84 10.48 4.75 6 150 4 5 100 125 11/e 11/8 29 29 3'/16 39/16 87 90 13.83 6.27 15.53 7.04 8 200 6 150 11 /4 32 37/8 98 29.10 13.20 Note: See page 37 for pressure -temperature ratings. PF-9.09 Not less than 2" nominal width (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4" 8 5" pipe Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bottom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of / steel beams. I� 'A Floor Joist Product Features • No pre -drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Rod Size Part Number Model Screw DescriptionsApprovals 2imate UL Test Box Casi 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 JI)t, 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 #14 SW Red = 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Nut Driver 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Part # 8114910 1. Insert the appropriate nut driver into a 318" or 1/2"portable drill 2. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 114", 318", 112" or metric all thread rod, bolt stock. (The 112" requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. E ff- A]m 0 El 1. Insert the appropriate nut driver into a 318" or 112" portable drill 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 114" 318" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.