Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-0230_Other_2.21.2022_12.43.25_PM_2692998
F DA/K/N ■ Standard Features • Compatible with Daikin One+ smart thermostat and other Daikin communicating equipment • Heavy-duty stainless -steel tubular heat exchanger • Stainless -steel secondary heat exchanger • Two -stage gas valve provides quiet, economical heating • Durable Silicon Nitride igniter • Quiet two -speed induced draft blower • Self -diagnostic control board with constant memory fault code history output to a dual 7-segment display • Color -coded low -voltage terminals with provi- sions for electronic air cleaner and humidifier • Efficient and quiet variable -speed airflow system gently ramps up or down according to heating or cooling demand • Multiple continuous fan speed options offer quiet air circulation • Auto -Comfort and enhanced dehumidification modes available • Can no longer be installed in California's South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019 • AHRI Certified; ETL Listed DM96VC TWO -STAGE, VARIABLE -SPEED COMMUNICATING ECM GAS FURNACE UP TO 9696 AFUE HEATING INPUT• 40,000-120,000 BTU/H ■ Contents Nomenclature ......................................... 2 Accessories ............................................. 2 Product Specifications ............................ 3 Dimensions ............................................. 4 Airflow Specifications ............................. 5 Wiring Diagram.......................................9 ■ Cabinet Features • Designed for multi -position installation: DM96VC: Upflow, horizontal left or right • Certified for direct vent (2-pipe) or non -direct vent (1-pipe) • Easy -to -install top venting with optional side venting • Convenient left or right connection for gas and electrical service • Cabinet air leakage (QLeak) <_ 2% • Heavy -gauge steel cabinet with durable finish • Fully insulated heat exchanger and blower section • Airtight solid bottom or side return with easy -cut tabs for effortless removal in bottom air -inlet applications ETA Us r' rr Intertek ® `- .k �MSOg� I Ill �E�Y.'TIF`ED "Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), the 12-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DM96VC www.daikincomfort.com 12/21 Supersedes 10/19 NOMENCLATURE D M 96 V C 060 3 B N A A BRAND D - DAIKIN CONFIGURATION M - UPFLOW/HORIZONTAL C - DOWNFLOW/HORIZONTAL AFUE 80-80%AFUE 92-92% AFUE 96-96AFUE 97-97%AFUE GAS VALVE M - MODULATING V - TWO -STAG E H - CONVERTIBLE TWO -STAGE S - SINGLE STAGE MOTOR C - VARIABLE SPEED ECM / COMMUNICATING E - MULTI -SPEED ECM S - MULTI SPEED PSC MBTU/H 040 - 40,000 BTU/H 100 - 100,000 BTU/H 060 - 60,000 BTU/H 120 - 120,000 BTU/H 080 - 80,000 BTU/H ACCESSORIES 3,4 5 6 7, 8, 9 10 11 12 13 F F F I � I MINOR REVISION A -INITIAL RELEASE B - 1ST REVISION MAJOR REVISION A -INITIAL RELEASE B - 1ST REVISION NOx N - Low NOx (40NG/J) CABINET WIDTH B - 17%z" C-21" D-24W' Maximum CFM 2 - 800 CFM 3-1200CFM 4-1600CFM 5 - 2000 CFM Daikin One+ Daikin Communicating Thermostat 0403BN V 0 V 0803BN V 0 V 1005CN V 1005DN V L1205D] V 72950 Concentric Vent Kit (2") V V V V V V — 72951 Concentric Vent Kit (3") V V V V V V V RF000142 Drain Kit Horizontal Left Vertical Flue V V V V V V V EFR02 External Filter Rack with 16"x25" Permanent Filter V V V V 0170K00000S Flush Mount Vent Kit - 3" or 2" V V V V V V V 0170K00001S Flush Mount Vent Kit - 2" V V V V V V — AFE18-60A Fossil Fuel (Dual Fuel) Kit V V V V V V V HASFK High -Altitude Natural Gas Kit HASFK-1 HASFK-1 HASFK-1 HASFK-2 HASFK-3 TBD HASFK-2 HASFK High -Altitude LP Gas Kit HASFK-1 HASFK-1 HASFK-1 HASFK-2 HASFK-2 TBD HASFK-2 0270F05404 Horizontal Drain Tubing Kit V V V V V V V LPLP03 Low LP Gas Pressure Switch V V V V V V V LPM-08 LP Conversion Kits V V V V V V V NOTES V Indicates available for this model z Indicates 9,001' to 11,000' altitude Indicates 7,001'to 9,000' altitude 3 Indicates 7,001'to 11,000' altitude • All installations above 7,000' require a pressure switch change. • For installation in Canada, gas furnaces are certified only to 4,500'. 2 www.daikincomfort.com SS-DM96VC PRODUCT SPECIFICATIONS HEATING DATA High Fire Input' 40,000 60,000 80,000 80,000 100,000 100,000 120,000 High Fire Output' 38,400 57,600 76,800 76,800 96,000 96,000 115,200 Low -Fire Steady -State Input' 28,000 42,000 56,000 56,000 70,000 70,000 84,000 Low -Fire Steady -State Output' 26,880 40,320 53,760 53,760 67,200 67,200 80,640 AFUE2 96 96 96 96 96 96 96 Temperature Rise Range (°F) 20- 50 35- 65 35- 65 25- 55 35- 65 30- 60 35- 65 Vent Diameter 2"- 3" 2"- 3" 2"- 3" 2"- 3" 2"- 3" 2"- 3" 2"- 3" NO. OF BURNERS 2 3 4 4 5 5 6 CIRCULATOR BLOWER Available AC @ 0.5" ESP 1.5- 3 1.5- 3 1.5- 3 1.5- 4 2-5 2-5 2-5 Size (D x W) 10" x 8" 11" x 8" 11" x 8" 11" x 10" 11" x 10" 11" x 11" 11" x 11" Horsepower @ 1075 RPM %2 1 %2 % 1 1 1 Speed VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM ELECTRICAL DATA Min. Circuit Ampacity° 7.8 7.8 7.8 10.6 14.4 14.4 14.4 Max. Overcurrent Device (amps)' 15 15 15 15 20 20 20 SHIPPING WEIGHT (LBS) 114 117 120 141 143 153 156 Natural Gas BTU/h DOE AFUE based upon Isolated Combustion System (ICS) Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/ code requirements and must be 2" or 3" diameter PVC. " Minimum Circuit Ampacity= (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. s Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection %" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. • For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS-DM96VC www.daikincomfort.com I�Ir�Iy�L�� ►ice Air Air Discharge Discharge 28% 6% A Air Intake Y. 2" Pipe 2% C 1'/e Z 19'/z 2 Center Dimple Left -Side For Alternate Vent/ Flue Pipe Alternate Drain Trap Air Intake Pipe 2" PVC Vent/ Flue Exterior Holes 3 . OD Hole Location High -Voltage Right -Side Electrical Outlet Drain Trap Exterior Holes Standard O High -Voltage Gas Supply Electrical Outlet Location Alternate Gas Supply 34% 31% A, 26% % 23 2423 19% 21% � 19% 14 9% 5 gy Ti 1% LEFT SIDE VIEW 1'/e FRONTVIEW Y. 1/ RIGHT SIDE VIEW Low -voltage 2'/e Low -Voltage 2% Electrical Outlet 2% D Electrical Outlet Unfolded Flanges 2% 1 % Condensate Drain 22 23 Trap Exterior E Unfolded Flanges Connection Folded Flanges (Right or Left Side) 23Y. % PVC Folded Flanges AIR DISCHARGE 16" 13%8" 12Ys" 13%" •o DM96VC0403BNA 17%" DM96VC0603BNA 17%2" 16" 13%8" 12Ys" 13%" DM96VC0803BNA 17%:" 16" 13%8" 12Ys" 13%" DM96VC0804CNA 21" 19%" 17%" 16" 17%" DM96VC1005CNA 21" 19%" 17%" 16" 17%" DM96VC1005DNA 24%" 23" 203/s" 19%" 20%8" DM96VC1205DNA 24%" 23" 203/s" 19%" 20%8" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS C = If placed on combustible floor, the floor MUST be wood ONLY. 4 www.daikincomfort.com SS-DM96VC I#]JV�I.1T#rA h7 .7►►lie e DM96VC0403BNA COOLING SPEED (@ X' -.8" w.c. ESP) TAP ADJUST Minus 10% HIGH -STAGE 536 Low -STAGE STAG E 363 Minus 5% 566 383 A Normal 596 403 Plus 5% 626 423 Plus 10% 656 443 Minus 10% 716 474 Minus 5% 756 501 B Normal 796 527 Plus 5% 836 553 Plus 10% 876 580 Minus 10% 877 608 Minus 5% 925 641 C Normal 974 675 Plus 5% 1,023 709 Plus 10% 1,071 743 Minus 10% 1,073 723 Minus 5% 1,132 763 D Normal 1,192 803 Plus 5% 1,252 843 Plus 10% 1 1,311 1 883 DM96VC0603BNA COOLING SPEED (@ .1" - .8" w.c. ESP) TAP ADJUST HIGH -STAGE Low -STAGE Minus 10% 539 358 Minus 5% 569 378 A Normal 599 398 Plus 5% 629 418 Plus 10% 659 438 Minus 10% 735 501 Minus 5% 776 529 B Normal 817 557 Plus 5% 858 585 Plus 10% 899 613 Minus 10% 906 626 Minus 5% 957 661 C Normal 1,007 696 Plus 5% 1,057 731 Plus 10% 1,108 766 Minus 10% 1,091 729 Minus 5% 1,151 770 D Normal 1,212 810 Plus 5% 1,273 851 Plus 10% 1,333 891 DM96VC0403BNA HEATING SPEED (@ .1" -.5" w.c. ESP; RISE RANGE: 20 - 507) TAP ADJUST Minus 10% HIGH -STAGE 891 LoW-STAGE 658 RISE 40 Minus 5% 941 694 38 A Normal 990 731 36 Plus 5% 1040 768 34 Plus 10% 1089 804 33 Minus 10% 977 720 36 Minus 5% 1031 760 34 B Normal 1085 800 33 Plus 5% 1139 840 31 Plus 10% 1194 880 30 Minus 10% 1067 765 33 Minus 5% 1126 808 32 C Normal 1185 850 30 Plus 5% 1244 893 29 Plus 10% 1304 935 27 Minus 10% 1151 820 31 Minus 5% 1215 865 29 D Normal 1279 911 28 Plus 5% 1343 957 26 Plus 10% 1 1407 1002 1 25 DM96VC0603BNA HEATING SPEED @ X' - .5" w.c. ESP; RISE RANGE: 35 - 65°F) TAP ADJUST Minus 10% HIGH -STAGE Low -STAGE 526 722 RISE 68 Minus 5% 550 751 65 A Normal 574 779 62 Plus 5% 606 810 61 Plus 10% 637 840 59 Minus 10% 669 881 58 Minus 5% 696 928 56 B Normal 723 975 53 Plus 5% 749 1019 52 Plus 10% 775 1062 50 Minus 10% 749 986 54 Minus 5% 774 1048 52 C Normal 799 1109 50 Plus 5% 836 1154 48 Plus 10% 872 1199 45 Minus 10% 900 1262 44 Minus 5% 945 1346 42 D Normal 989 1429 39 Plus 5% 1038 1423 39 Plus 10% 1087 1416 38 NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. MINIMUM FILTER SIZES Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. SS-DM96VC www.daikincomfort.com DM96VC AIRFLOW DATA (CONT.) DM96VC0803BNA COOLING SPEED (@ .1" - .8" w.c. ESP) TAP ADJUST HIGH -STAGE LoW-STAGE Minus 10% 566 363 Minus 5% 598 383 A Normal 629 403 Plus 5% 660 423 Plus 10% 692 443 Minus 10% 725 486 Minus 5% 766 513 B Normal 806 540 Plus 5% 846 567 Plus 10% 887 594 Minus 10% 921 635 Minus 5% 972 670 C Normal 1,023 705 Plus 5% 1,074 740 Plus 10% 1,125 776 Minus 10% 1,107 737 Minus 5% 1,169 778 D Normal 1,230 819 Plus 5% 1,292 860 Plus 10% 1,353 901 DM96VC0804CNA COOLING SPEED (@X' -.8" w.c. ESP) TAP ADJUST HIGH -STAGE CIF LoW-STAGE CIFM Minus 10% 710 462 Minus 5% 750 487 A Normal 789 513 Plus 5% 828 539 Plus 10% 868 564 Minus 10% 870 594 Minus 5% 919 627 B Normal 967 660 Plus 5% 1,015 693 Plus 10% 1,064 726 Minus 10% 1,064 712 Minus 5% 1,123 751 C Normal 1,182 791 Plus 5% 1,241 831 Plus 10% 1,300 870 Minus 10% 1,238 822 Minus 5% 1,306 867 D Normal 1,375 913 Plus 5% 1,444 959 Plus 10% 1,513 1,004 DM96VC0803BNA HEATING SPEED (@ X' - .5" w.c. ESP; RISE RANGE: 35 - 65°F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 1,082 770 n/a Minus 5% 1,142 812 62 A Normal 1,202 855 59 Plus 5% 1,262 898 56 Plus 10% 1,322 941 54 Minus 10% 1,184 831 60 Minus 5% 1,250 877 57 B Normal 1,316 923 54 Plus 5% 1,382 969 51 Plus 10% 1,448 1,015 49 Minus 10% 1,250 930 57 Minus 5% 1,320 981 54 C Normal 1,389 1,033 51 Plus 5% 1,458 1,085 49 Plus 10% 1,528 1,136 47 Minus 10% 1,256 957 57 Minus 5% 1,326 1,010 54 D Normal 1,396 1,063 51 Plus 5% 1,466 1,116 49 Plus 10% 1,536 1,169 46 DM96VC0804CNA HEATING SPEED (@ X' - .5" w.c. ESP; RISE RANGE: 25 - 55°F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 1,082 780 na/ Minus 5% 1,142 824 n/a A Normal 1,202 867 n/a Plus 5% 1,262 910 n/a Plus 10% 1,322 954 54 Minus 10% 1,184 845 n/a Minus 5% 1,250 892 n/a B Normal 1,316 939 54 Plus 5% 1,382 986 51 Plus 10% 1,448 1,033 49 Minus 10% 1,250 914 n/a Minus 5% 1,320 965 54 C Normal 1,389 1,016 51 Plus 5% 1,458 1,067 49 Plus 10% 1,528 1,118 47 Minus 10% 1,256 969 n/a Minus 5% 1,326 1,023 54 D Normal 1,396 1,077 51 Plus 5% 1,466 1,131 49 Plus 10% 1,536 1,185 46 NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. www.daikincomfort.com SS-DM96VC DM96VC AIRFLOW DATA (CONT.) DM96VC1005CNA COOLING SPEED (@ .1" - .8" w.c. ESP) TAP ADJUST HIGH -STAGE CIF LoW-STAG E CFM Minus 10% 738 508 Minus 5% 779 536 A Normal 820 564 Plus 5% 861 592 Plus 10% 902 620 Minus 10% 1,020 706 Minus 5% 1,076 745 B Normal 1,133 784 Plus 5% 1,190 823 Plus 10% 1,246 862 Minus 10% 1,318 884 Minus 5% 1,391 933 C Normal 1,464 982 Plus 5% 1,537 1,031 Plus 10% 1,610 1,080 Minus 10% 1,562 1,133 Minus 5% 1,649 1,196 D Normal 1,736 1,259 Plus 5% 1,823 1,322 Plus 10% 1,910 1,385 DM96VC1005DNA COOLING SPEED (@ X' - .8" w.c. ESP) TAP ADJUST HIGH -STAGE LoW-STAGE Minus 10% 806 537 Minus 5% 850 567 A Normal 895 597 Plus 5% 940 627 Plus 10% 985 657 Minus 10% 1,040 767 Minus 5% 1,098 809 B Normal 1,156 852 Plus 5% 1,214 895 Plus 10% 1,272 937 Minus 10% 1,313 928 Minus 5% 1,386 979 C Normal 1,459 1031 Plus 5% 1,532 1083 Plus 10% 1,605 1134 Minus 10% 1,678 1,154 Minus 5% 1,771 1,218 D Normal 1,864 1282 Plus 5% 1,957 1346 Plus 10% 2,050 1410 DM96VC1005CNA HEATING SPEED (@ X' - .5" w.c. ESP; RISE RANGE: 35 - 65°F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 1,636 1,130 54 Minus 5% 1,727 1,193 51 A Normal 1,818 1,256 49 Plus 5% 1,909 1,319 47 Plus 10% 2,000 1,382 44 Minus 10% 1,683 1,163 53 Minus 5% 1,777 1,227 50 B Normal 1,870 1,292 48 Plus 5% 1,964 1,357 45 Plus 10% 2,057 1,421 43 Minus 10% 1,719 1,184 52 Minus 5% 1,815 1,250 49 C Normal 1,910 1,316 47 Plus 5% 2,006 1,382 44 Plus 10% 2,101 1,448 42 Minus 10% 1,761 1,222 50 Minus 5% 1,859 1,290 48 D Normal 1,957 1,358 45 Plus 5% 2,055 1,426 43 Plus 10% 2,153 1,494 41 DM96VC1005DNA HEATING SPEED - .5" w.c. ESP; RISE RANGE: 35 - 65°F) TAP ADJUST HIGH -STAGE LoW-STAGE RISE Minus 10% 1,515 1,085 59 Minus 5% 1,599 1,145 56 A Normal 1683 1205 53 Plus 5% 1,767 1,265 50 Plus 10% 1,851 1,326 48 Minus 10% 1,554 1,107 57 Minus 5% 1,641 1,169 54 B Normal 1727 1230 51 Plus 5% 1,813 1,292 49 Plus 10% 1,900 1,353 47 Minus 10% 1,587 1,130 56 Minus 5% 1,675 1,193 53 C Normal 1763 1256 50 Plus 5% 1,851 1,319 48 Plus 10% 1,939 1,382 46 Minus 10% 1,616 1,153 55 Minus 5% 1,706 1,217 52 D Normal 1796 1281 49 Plus 5% 1,886 1,345 47 Plus 10% 1,976 1,409 45 NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-DM96VC www.daikincomfort.com DM96VC AIRFLOW DATA (CONT.) DM96VC1205DNA COOLING SPEED (@ X' - .8" W.C. ESP) TAP ADJUST Minus 10% HIGH -STAGE 780 LoW-STAG E 492 Minus 5% 824 520 A Normal 867 547 Plus 5% 910 574 Plus 10% 954 602 Minus 10% 1,044 748 Minus 5% 1,102 789 B Normal 1,160 831 Plus 5% 1,218 873 Plus 10% 1,276 914 Minus 10% 1,320 918 Minus 5% 1,394 969 C Normal 1,467 1,020 Plus 5% 1,540 1,071 Plus 10% 1,614 1,122 Minus 10% 1,719 1,150 Minus 5% 1,815 1,214 D Normal 1,910 1,278 Plus 5% 2,006 1,342 Plus 10% 2,101 1,406 DM96VC1205DNA HEATING SPEED w.c. ESP; RISE RANGE: 3S - 6S`F) TAP ADJUST Minus 10% HIGH -STAGE 1,702 LoW-STAGE 1,196 RISE 63 Minus 5% 1,796 1,263 59 A Normal 1,891 1,329 56 Plus 5% 1,986 1,395 54 Plus 10% 2,080 1,462 51 Minus 10% 1,746 1,226 61 Minus 5% 1,843 1,294 58 B Normal 1,940 1,362 55 Plus 5% 2,037 1,430 52 Plus 10% 2,134 1,498 50 Minus 10% 1,771 1,251 60 Minus 5% 1,870 1,321 57 C Normal 1,968 1,390 54 Plus 5% 2,066 1,460 52 Plus 10% 2,165 1,529 49 Minus 10% 1,825 1,296 58 Minus 5% 1,927 1,368 55 D Normal 2,028 1,440 53 Plus 5% 2,129 1,512 50 Plus 10% 2,231 1,584 48 NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. www.daikincomfort.com SS-DM96VC o_a GND r TO115 VAC/ 1 0 /60 HZ C �r POWER SUPPLY W ITH ID BLOWER TWO PRESSURE PROTECTION DEVICE OVERCURRENT Jy SW ITCH ASSEMBLY O I L WARNIm BK POWER BEFORDISCE HIGH FIRE * POWER BEFORE HOT OR PRESSUREJ 1 � � �N SERVICING. WIRING LOW FIRE 'ED SURFACE PRESSUR SWITCH p WH TO UNIT MUST BE IGNITER E SWITCH DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED. c CONNECTOR OR TO 115VAC/ 10 /60 HZ POWER SUPPLY WITH 9 HI a PU OVERCURRENT PROTECTION DEVICE TWO STAGE L GND I i GAS VALVE C z BR FLAME WARNING: SENSOR (GAS DISCONNECT POWER PM 1 GY GY BEFORE SERVICING. FRONT COVER WIRING TO UNIT PRESSURE SWITCH MUST BE PROPERLY POLARIZED AND DISCONNECT MANUAL RESET ROLLOUT LIMIT GROUNDED. CONTROLS (SINGLE CONTROL ON s 40 kBTN BL PKU) R N DOOR (/J SWITCH L J J L J JUNCTION BOX AUTO RESET PRIMARV 0 LIMIT CONTROL O PD C INDUCTOR COIL Z (ON SOME MODELS) O INDUCED GND INDOOR 3 WH DRAFT AIR 2 RD BLOWER Z CIRBCLWARTO BK IN GND BURNER COMPARTMENT GND LINE SEE NOTE 6 NEUTRAL BLOWER COMPARTMENT PU HUMIDIFIER = AUTO RESET LIMIT ONTROL HUM UM -OUT - m AUXILIARY YL -- NEUTRAL SUM IDIFIR . NEUTRAL JJ W C O o EAC ELECTRONIC , i AI`CLEAN�R I 0 p IND HI cL 0 BLWR O $c W 3 ' = 2 IND LO NEUTRAL ' DO HOG IGNITER FS 0 ]p0 VVH III$. FLAME SENSOR LINE W LBL LINE 115 VAC NEUTRAL Coo VA F m BL FUSE3A TH (4) TRANSFORMER TRIMAe� Oa GV 24 VAC AUTO RESET PRIMARY COOL PRFL �� - I wcoNROLS wuxwwaYUMIT LIMITCONTROL p m BK TO HLo 6 z HEAT AF RD s 9n940VA PL O TRANSFORMER m I1 IPS01T TRIM [n x YL GV O CONT PAN LE�v+ y 24 n W P51 2 SWITCHE PRESS. BR PK 1 I�I 0929 VAC O c —OR O HEAT OFF OLvI^I��II m 90 v j 115 (��1�,1 --, I NO T-SiAT� VAC II PS2 (12) NO z TO H/PU z 0 m Y MICRO HIGH FIRE C E O pI LENOSTIC py ^ II PRESS. SW CH MANUAL RESET R LOUT G LIMIT CONTROLS ROLLOUT W NOTE5 ® D'S O ]0 O HLI (1) 24 V Dom n = O v. .A j { MVL (13) FNO AO PM FUSE I IMvc(6) C PRESSUREswITCIT HI C IMVH(14) ECM MT I GND (5 ow5 HARNESS a ITR 11 VALVE WH BK WH BF( TO IGND (4) R s a BK . VD c (1) WH IRX(2) INDOOR Z 2 K,;" TOGND BLOWER MICRO ITX (3) AIR CULATOR COMPARTMENT DOOR SWITCH = e e (OPEN WHEN INTEGRATED CONTROL MODULE i CIRCULATOR BLOWER I INDUCTOR COIL DOOR OPEN) (ON SOME MODELS) NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF COLOR CODES: LOW VOLTAGE (24V) EQUIPMENT GND ri7 AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. PK PINK — — FIELD GND 1 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH BR BROWN LOW VOLTAGE FIELD FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) WH WHITE HI VOLTAGE (115V) FIELD SPLICE [] 6. HUMIDIFIER INSTALLATION OPTIONS: USE HUM TERMINAL TO RUN HUMIDIFIER DURING BL BLUE HEAT CALL (COMMUNICATING OR LEGACY MODES). USE HUM -IN AND HUM -OUT GY GRAY HI VOLTAGE FIELD SWITCH TEMP. o�a (TEMP.) TERMINALS TO RUN HUMIDIFIER DURING HEAT CALL ( COMMUNICATING MODE OR LEGACY MODE) OR INDEPENDENTLY FROM HEAT CALL (COMMUNICATING MODE ONLY- RD RED SETUP IS DONE WITHIN COMMUNICATING THERMOSTAT) YL YELLOW JUNCTION IGNITER 1J7J-Lr OR ORANGE TERMINAL PU PURPLE INTERNAL.) SWITCH (PRESS GN GREEN INTEGRATED CONTROL OVERCURRENT SK BLACK PLUG CONNECTION PROT. DEVICE IEEE] 0140F02006-E 3 0 3 01 E b00 R @ m O i a ' z O D, . SS-DM96VC www.daikincomfort.com 9 NOTES 10 www.daikincomfort.com SS-DM96VC NOTES SS-DM96VC www.daikincomfort.com 11 NOTES Our continuing commitment to quality products may mean a change in specifications without notice. ©2021 DA/K/NMANUFACTUR/NGCOMPANY, L.P. • Houston, Texas • Printed in the USA 12 www.daikincomfort.com SS-DM96VC