Loading...
Correction Response - Greer Solarium - BLD2020-0015 - Cycle 2lN(thwest Permit Inc.,-,.. w w w. n w p e r m I t. c o m February 241h, 2020 City of Edmonds Subiect — Correction Response — Cycle 1 Project # BLD2020-0015 Corrections & Responses Attn: Kevin Bloomfield 1. Additions to an existing building or portion thereof shall conform to the provisions of the 2015 WSEC as those provision relate to new construction without reauirine the unaltered portion of the existing building or building system to comply with this code. The sunroom is being indirectly heated by the rest of the home. Alterations under 500 square feet reauire a .5 enerev credit. Enerev credits can be found in Table 406.2 in the 2015 WSEC. Once you have selected the option being used document this on the plans. Include all the information into table R402.1.1 and include this with the plans. a. Please see updated plan set to include a new sheet A0.1 to contain the selected credit option and prescriptive table R402.1.1 with updated values. Page A4 2. The archwav between the two rooms has created two point loads. Please Show location of thickened areas in the existing foundation. a. Please see updated sheet A4 to reflect the location of the thickened foundation areas per detail 19 on sheet D7 Please contact me if you have any questions or concerns. Sincerely, Northwest Permit Inc. William Millhollin — Vice President & Commercial Account Manager William@nwpermit.com / Cell # 206-601-7043