APPROVED BLD-BLD2021-0108+Structural_Analysis_or_Calculations+1.27.2021_8.36.52_AM+2012384RECEIVED Jan 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0108 Project Name Project Number: 21-003 9701 226th PI. SW Edmonds, WA 98021 Structural Calculations REVIEWED BY CITY OF EDMONDS € BUILDING DEPARTMENT Calculations................................................S1 — S13 �p'u SA� WASy��9 46136 �v �SSIONAS 1 /25/21 Reviewed by: Nabil Kausal-Hayes, PE 206-601-9728 www.nkhengineering.com Prepared By: Allen Rishel, EIT January 25th, 2021 NKH Background PROJECT: Kossian Remodel DESIGNER: NKH &AKR DATE: January 25th, 2021 JOB #: 21-003 PROJECT SUMMARY & DESIGN CRITERIA Project Summary: This is a bearing wall removal on a single story, wood framed house for Julianne Kossian in Edmonds, WA. The structure consists of wood roof/ceiling & floor joists bearing on wood framed walls, posts, & beams. The house is supported by existing concrete stem walls & shallow spread footings. This project is designed in accordance with the 2015 International Building Code along with the codes listed below and corresponding state & city/county amendments. Notes: All input variables are highlighted in yellow, resources bolded, and links to resources bolded and underlined. Areas highlighted in blue are code/design checks and green - unity checks. Resources: -American Wood Council (AWC). (2015). "National Design Specifications for Wood Construction (NDS)." -American Wood Council (AWC). (2015). "Special Design Provisions for Wind and Seismic (SDWS)." -American Concrete Institute (ACI). (2014). 'Building Code Requirements for Structural Concrete (ACI 318-14)." -American Institute of Steel Construction (AISC). (2011). "Steel Construction Manual." 14th Ed. -American Society of Civil Engineers (ASCE). (2010). "Minimum Design Loads for Buildings and Other Structures." -StateofWashngton (2015)."International Building Code (IBC)." -Applied Technology Council (ATC). (2018). "Hazards by Location" https:Hhazards.atcouncil.org Material Properties Soil: -Soil Bearing Pressure (min per IBC1806.2) -Frost Depth -Active & Passive Soil Pressure Concrete: -Compressive Strength -Density, Normal Weight -Density, Light Weight -Reinforcing Steel, ASTM A615 Steel: - Modulus of Elasticity -Anchor Rods/Bolts, ASTM A307 Shear & Tension Yield Strength Wood: -Solid Sawn Joists, Beams, Headers, & Studs -Glulam Beams pbrg:= 1500psf FD:= 18in qa:= 35•pcf qp:= 250•pcf fc:= 2500psi -yconc 150pcf -yconc LW 115pcf fyr:= 60ksi Ec:= 29000ksi Fnv:= 24ksi Fnt:= 45ksi DF-L #1 6x & Larger, DF-L#2 All Other (UNO) 24F-V4 (Simple Span), 24F-V8 (Cont/Cantilever) 01_Summary Design Criteria.xmcd S1 Gravity Loadin v Roof Dead Load Roofing R : = 1.5• psf Insulation I:= 2.0•psf Ceiling C := 2• psf Sheathing t:= 0.5in SH:= t 1.0.4-psf = 1.6-psf (.125in) Structural Members S := 2.5- psf Lights L:= I-psf Mechanical M:= 1.5•psf Misc. MISC := 2.9• psf DLrf:= R+ I+ C + SH+ S + L + M + MISC Floor Dead Load Flooring F : = 1.5- psf Insulation I:= 2.0•psf Ceiling C := 0- psf Sheathing t:= 0.75in SH:= l t I.0.4•psf = 2.4•psf (.125in) Structural Members S := 3.4- psf Lights L:= I-psf Mechanical M:= 1.5-psf Misc. MISC := 3.2• psf DLflr:= R+ I+ C + SH+ S+ L+ M + MISC Wall Dead Loads Exterior Wood pext w:= 1Opsf Interior Wood pint := 9psf Live Loads Roof LLrf:= 20.psf Floor Live Load LLflr:= 40psf Deflection Criteria L Arf TL:= Arf LL:= L L L Af1r TL:= Af1r_LL:= 240 360 360 480 DLrf = 15•psf DL flr = 15• psf Roof Snow Load DLpv:= Opsf SL:= 25psf 01_Summary Design Criteria.xmcd S2 a" O R T CM MEMBER REPORT PASSED Roof, New Flush Beam 1 piece(s) 5 1/2" x 15" 24F-V4 DF Glulam Overall Length: __ 1 1 22 L 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 5730 @ 4" 19663 (5.50") Passed (29%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 4876 @ 1' 8 1/2" 16761 Passed (29%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 30945 @ 11' 5 1/2" 45799 Passed (68%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.594 @ 11' 5 1/2" 0.742 Passed (L/449) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.990 @ 11' 5 1/2" 1 1.112 1 Passed (L/270) 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 0.97 that was calculated using length L = 22' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports IV Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Column - DF 5.50" 5.50" 1.60" 2292 2750 3438 8480 Blocking 2 - Column - DF 5.50" 5.50" 1.60" 2292 2750 3438 8480 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 22' 11" o/c Bottom Edge (Lu) 22' 11" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 22' 11" N/A 20.0 1 - Uniform (PSF) 0 to 22' 11" (Top) 12' 15.0 20.0 25.0 Default Load System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : Aso Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Allen Rishel NKH Engineering (206) 641-1733 allen@nkhengineering.com 1/26/2021 6:00:19 AM UTC ForteWEB 0. 1, Engine: V8.1.5.1, Data: V80.11.0 Weyerhaeuser File Name: 20-003 Kossian Bearing-.0UPall Paget/2 CCQ/ECCQ Column Caps ?G This product is preferable to similar connectors because of (a) easier installation, (b) higher loads, (c) lower installed ;> cost, or a combination of these features. Q M Column caps provide a strong connection for column -beam U combinations. This design uses Strong -Drive® SIDS Heavy -Duty Connector screws to provide faster installation and provides a N greater net section area of the column compared to bolts. The SIDS a) screws provide for a lower profile compared to standard through bolts. m Material: CCQ3, ECCQ3, CCQ4, CCQ4.62, ECCQ4, ECCQ4.62, CCQ6, ECCQ6 — 7 gauge; all others — 3 gauge Finish: Simpson Strong Tie gray paint; available in HDG and stainless steel; CCOQ and ECCOQ — no coating Installation: • Install 1/4" x 21/2" Strong -Drive SIDS Heavy -Duty Connector screws, which are provided with the column cap. (Lag screws will not achieve the same load.) Install stainless -steel Strong -Drive screws with stainless -steel connectors. • CCOQ and ECCOQ column caps only (no straps) may be ordered for field -welding to pipe or other columns. Dimensions are same as CCQ and ECCQ. Weld by Designer. • For rough -cut lumber sizes, provide dimensions. An optional W2 dimension may be specified with any column size given. (Note that the W2 dimension on straps rotated 90° is limited by the W1 dimension.) Options: • For end conditions, specify ECCQ. • Straps may be rotated 90° where W1 2! W2 and for CCQ5-6. • Other custom column caps are available. Contact Simpson Strong -Tie. Codes: See p.12 for Code Reference Key Chart Inverted CCQ44SDS2.5 Post -to -Beam Installation i ECCQ46SDS2.5 6CCOQ4-SDS2.5 (no coating) Typical CCQ46SDS2.5 Installation StrongTie C�CCQ46SDS2.5 Optional CCQ with Straps Rotated 90° rni,. ® ® o mi, Weld by Designer CCOQ Installation on Steel Column 88 S4 CCQ/ECCQ Column Caps (cont.) These products are available with additional corrosion For stainless -steel protection. For more information, see p.15. ® fasteners, see p. 21. Model No. Beam Width (in) Dimensions (in.) No. of/4" x 21/2" SIDS Screws Allowable Loads (DF/SP) Code Ref. W1 W2 L H CCQ ECCQ Beam Post Uplift Down Uplift Down CCQ ECCQ CCQ ECCQ (160) (100) (160) (100) CC03-4SDS2.5 3% 31/4 3% 11 81/2 7 16 14 14 5,370 16,980 3,465 6,125 CC03-6SDS2.5 31/3 31/4 51/2 11 81/2 7 16 14 14 5,370 21,485 3,465 10,740 CC044SDS2.5 31/2 3% 3% 11 81/2 7 16 14 14 5,370 19,020 3,785 7,655 CC046SDS2.5 31/2 3% 51/2 11 81/2 7 16 14 14 6,785 24,065 3,785 12,030 CC048SDS2.5 31/2 3% 71/2 11 81/2 7 16 14 14 6,785 24,065 3,785 16,405 CC04.62-3.62SDS 41/2 4% 3% 11 81/2 7 16 14 14 5,370 23,390 3,785 9,845 CC04.62-4.62SDS 41/2 4% 4% 11 81/2 7 16 14 14 5,370 30,070 3,785 12,655 CC04.62-5.50SDS 41/2 4% 51/2 11 81/2 7 16 14 14 6,785 30,940 3,785 15,470 CC05-4SDS2.5 5% 51/4 3% 11 81/2 7 16 14 14 5,370 26,635 4,040 11,210 CC05-6SDS2.5 5% 51/4 51/2 11 81/2 7 16 14 14 6,785 28,190 5,355 17,615 CC05-8SDS2.5 5% 51/4 71/2 11 81/2 7 16 14 14 6,785 35,235 5,355 24,025 CCQ64SDS2.5 51/4, 51/2 51/2 35/3 11 81/2 7 16 14 14 5,370 28,585 3,785 12,030 CC066SDS2.5 51/4, 51/2 51/2 51/2 11 81/2 7 16 14 14 6,785 33,275 3,785 18,905 CC068SDS2.5 51/4, 51/2 51/2 71/2 11 81/2 7 16 14 14 6,785 37,815 3,785 25,780 CC06-7.13SDS2.5 51/4, 51/2 51/2 71/3 11 81/2 7 16 14 14 6,785 37,815 3,785 24,490 CCQ74SDS2.5 63/4 67/3 3% 11 81/2 7 16 14 14 5,370 33,490 4,040 15,355 IBC, FL, LA CC076SDS2.5 63/4 67/3 51/2 11 81/2 7 16 14 14 6,785 37,125 5,355 24,130 CC077SDS2.5 63/4 67/3 67/3 11 81/2 7 16 14 14 6,785 48,265 5,355 29,615 CC078SDS2.5 63/4 67/3 71/2 11 81/2 7 16 14 14 6,785 48,265 5,355 32,905 CC07.1-4SDS2.5 7 71/3 3% 11 81/2 7 16 14 14 5,370 34,730 4,040 18,375 CC07.1-6SDS2.5 7 71/3 51/2 11 81/2 7 16 14 14 6,785 38,500 5,355 28,875 CC07.1-7.1SDS2.5 7 71/3 71/3 11 81/2 7 16 14 14 6,785 57,750 5,355 36,750 CC07.1-8SDS2.5 7 71/3 71/2 11 81/2 7 16 14 14 6,785 52,500 5,355 39,375 CCQ84SDS2.5 71/2 71/2 3% 11 81/2 7 16 14 14 6,785 37,210 5,355 16,405 CC086SDS2.5 71/2 71/2 51/2 11 81/2 7 16 14 14 6,785 41,250 5,355 25,780 CCQ88SDS2.5 71/2 71/2 71/2 11 81/2 7 16 14 14 6,785 51,565 5,355 35,155 CCQ94SDS2.5 83/4 87/3 3% 11 81/2 7 16 14 14 6,785 47,545 5,355 19,905 CCQ96SDS2.5 83/4 87/3 51/2 11 81/2 7 16 14 14 6,785 48,125 5,355 31,280 CCQ98SDS2.5 83/4 87/3 71/2 11 81/2 7 16 14 14 6,785 62,565 5,355 42,655 CCQ106SDS2.5 91/4 91/2 51/2 11 81/2 7 16 14 14 6,785 52,250 5,355 32,655 Strong -Tie N CCOQ/ECCOQ CL Model No. (No Legs) U C cC CC003-SDS2.5 N ECC003-SDS2.5 N R m CCOQ4-SDS2.5 ECC004-SDS2.5 CC004.62-SDS2.5 CCOQ5-SDS2.5 ECC005-SDS2.5 CCOQ6-SDS2.5 ECCO06-SDS2.5 CC007-SDS2.5 ECCOQ7-SDS2.5 CCOQ7.12-SDS2.5 ECC007.12-SDS2.5 CCO08-SDS2.5 ECC008-SDS2.5 CCOQ9-SDS2.5 ECCO09-SDS2.5 CCO010-SDS2.5 ECC0010-SDS2.5 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern. 2. Downloads shall be reduced where limited by capacity of the post. 3. Uplift loads do not apply to spliced conditions. Spliced conditions must be detailed by the Designer to transfer tension loads between spliced members by means other than the post cap. 4. Spliced conditions must be detailed by the Designer to transfer tension loads between spliced members by means other than the column cap. 5. Column sides are assumed to be aligned in the same vertical plane as the beam sides. CCQ4.62 models assume a minimum 31/2"-wide post. 6. Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers known as the narrow face. Values in the tables reflect installation into the wide face. See technical bulletin T-C-SCLCLM at strongtie.com for load reductions resulting from narrow -face installations. 7. Beam depth must be a minimum of 7". 8. For 51/4" engineered lumber, use 51/2" models. 9. CCOQ and ECCOQ welded to a steel column will achieve maximum load listed as CCQ and ECCQ. The steel column width shall match the beam width. Weld by Designer. S5 89 NKH Engineering nkhengineering.com Project Title: Kossian Remodel Engineer: NKH Project ID: 21-003 Project Descr: Printed: 25 JAN 2021, 10:03PM Wood Column File: Posts & Footings.ec6 ` Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.1 i KW-06012717 DESCRIPTION: New Post Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Analysis Method : Allowable Stress Design End Fixities Top & Bottom Pinned Overall Column Height 8 ft ( Used for non -slender calculations ) Wood Species Douglas Fir - Larch Wood Grade No.2 Fb + 900 psi Fv 180 psi Fb - 900 psi Ft 575 psi Fc - Prll 1350 psi Density 31.21 pcf Fc - Perp 625 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1600 1600 Minimum 580 580 Wood Section Name 4x6 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 3.50 in Allow Stress Modification Factors Exact Depth 5.250 in Cf or Cv for Bending 1.0 Area 19.25 inA2 Cf or Cv for Compression 1.0 Ix 266.93 inA4 Cf or Cv for Tension 1.0 ly 68.78 inA4 Cm : Wet Use Factor 1.0 Ct : Temperature Factor 1.0 Cfu : Flat Use Factor 1.0 Axial Kf : Built-up columns 1.0 NDS 15.3.2 1600 ksi Use Cr : Repetitive ? No Brace condition for deflection (buckling) along columns : X-X (width) axis: Fully braced against buckling ABOUT Y-Y Axis Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 8 ft, K =1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 33.377 Ibs * Dead Load Factor AXIAL LOADS ... New Beam: Axial Load at 8.0 ft, D = 2.30, Lr = 2.750, S = 3.440 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.3062 : 1 Maximum SERVICE Lateral Load Reactions. . Load Combination +D+S Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along XA 0.0 k Bottom along XA 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections.. . At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 5.773 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along XA 0.0 in at 0.0 ft above base Fc: Allowable 1,025.99 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio = Load Combination Location of max.above base Applied Design Shear Allowable Shear Load Combination Results 0.0:1 Bending Compression +0.60D 8.0 ft 0.0 psi 288.0 psi Load Combination C D C P Maximum Axial + Bending Stress Ratio Status Stress Ratios Location D Only 0.900 0.743 0.1406 PASS 0.0 ft +D+Lr 1.250 0.630 0.2601 PASS 0.0 ft +D+S 1.150 0.661 0.3062 PASS 0.0 ft +D+0.750Lr 1.250 0.630 0.2250 PASS 0.0 ft +D+0.750S 1.150 0.661 0.2606 PASS 0.0 ft +0.60D 1.600 0.536 0.06579 PASS 0.0 ft Maximum Reactions Tension Maximum Shear Ratios Stress Ratio Status Location 0.0 PASS 8.0 ft 0.0 PASS 8.0 ft 0.0 PASS 8.0 ft 0.0 PASS 8.0 ft 0.0 PASS 8.0 ft 0.0 PASS 8.0 ft Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top D Only 2.333 S6 NKH Engineering nkhengineering.com Project Title: Kossian Remodel Engineer: NKH Project ID: 21-003 Project Descr: Printed: 25 JAN 2021, 10:03F Wood Column File: Posts & Footings.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.1 i DESCRIPTION: New Post Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top +D+Lr 5.083 +D+S 5.773 +D+0.750Lr 4.396 +D+0.750S 4.913 +0.60D 1.400 Lr Only 2.750 S Only 3.440 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance D Only 0.0000 in 0.000 ft +D+Lr 0.0000 in 0.000 ft +D+S 0.0000 in 0.000 ft +D+0.750Lr 0.0000 in 0.000 ft +D+0.750S 0.0000 in 0.000 ft +0.60D 0.0000 in 0.000 ft Lr Only 0.0000 in 0.000 ft S Only 0.0000 in 0.000 ft Sketches c 0 LO N LO 3.50 in Load 1 0.0000 in 0.000 ft 0.0000 in 0.000 ft 0.0000 in 0.000 ft 0.0000 in 0.000 ft 0.0000 in 0.000 ft 0.0000 in 0.000 ft 0.0000 in 0.000 ft 0.0000 in 0.000 ft 8490k 8A98k 11 y TX Lt 1 �J+Jl _J S7 PCZ/EPCZ Post Caps PCZ/EPCZ post caps are designed with their post and beam flanges in -line so that one PCZ/EPCZ model can accommodate several post sizes. The PCZ/EPCZ uses 0.148" x 3" nails. An alternate choice of fastener is the #9 x 11/2" Strong -Drive® SD Connector screw. ZMAX® finish is standard to meet exposure conditions in many environments. See additional corrosion information at strongtie.com/info. Material: 16 gauge Finish: ZMAX coating Installation: • Use all specified fasteners; see General Notes • Do not install bolts into pilot holes Options: • For end conditions, specify EPCZ post caps • For heavy-duty applications, see CCQ and CC Series • For retrofit applications, see AC and LCE Series Codes: See p.12 for Code Reference Key Chart �V ® ON ® 3" U elm ® ®m Pilot holes for g 1sj8' w ® manufacturing ° 25/$ purposes (Do not install 25i8° Post flange bolts) (typ.) PCZ - These products are available with additional corrosion protection. For more information, see p.15. ®Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Typical PCZ Post Cap Installation Model No. W (in.) Fasteners (in.) Post Size Allowable Loads (DF/SP) Code Ref. PCZ EPCZ Beam Post Uplift (160) Lateral (160) Uplift (160) Lateral (160) PC4Z 39/e (10) 0.148 x 3 (8) 0.148 x 3 (2) 2x4 1,480 1,120 1,130 895 44 1,480 1,260 1,130 1,075 46 1,480 1,260 1,130 1,230 48 1,480 1,380 1,130 1,230 PC6Z 51/2 (10) 0.148 x 3 (8) 0.148 x 3 46 1,480 1,260 1,435 1,075 113C, FL, LA 6x6 1,480 1,295 1,435 1,230 6x8 1,480 1,380 1,435 1,230 PC8Z 71/2 (10) 0.148 x 3 (8) 0.148 x 3 48 1,480 1,260 1,435 1,075 6x8 1,480 1,295 1,435 1,230 8x8 1,480 1,380 1,435 1,230 1. Allowable loads have been increased for wind or earthquake loading with no further increase allowed. Reduce where other loads govern. 2. Uplift loads do not apply to spliced conditions. Spliced conditions must be detailed by the Designer to transfer tension loads between spliced members by means other than the post cap. 3. Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers known as the narrow face. Values in the tables reflect installation into the wide face. See technical bulletin T-C-SCLCLM at strongtie.com for load reductions resulting from narrow -face installations. 4. Post and beam may consist of multiple members provided they are connected independently of the post cap fasteners. 5. 0.148" x 21/2" nails may be used with no load reduction for uplift and 0.85 of the table loads for lateral. 6. #9 x 11/2" Strong -Drive® SD Connector screws may be substituted for table fasteners with no load reduction. 7. To order models available for rough size lumber, specify RZ suffix - e.g., PC4RZ. 8. Fasteners: Nail dimensions in the table are diameter by length. See pp. 21-22 for fastener information StrongTie o ° � U o y ° Pilot holes for d Post flan g a manufacturing purposes M - W (Do not install Cal bolts) (typ.) EPCZ ____T a Typical EPCZ End Post Cap Installation Shim by Desigi EPCZ Post Cap Installed on Double 2x Members Shim by PCZ Post Cap Installed on Double 2x Members S8 87 ABA/ABU/ABW Adjustable and Standoff Post Bases Additional standoff bases are on p. 321. The AB series of retrofit adjustable post bases provide a 1 " standoff for W the post, are slotted for adjustability and can be installed with nails, CStrong -Drive® SD Connector screws or bolts (ABU). Depending on the V application needs, these adjustable standoff post bases are designed for versatility, cost-effectiveness and maximum uplift performance. = Features: W • The slot in the base enables flexible positioning around the anchor bolt, U) making precise post placement easier m • The 1 " standoff helps prevent rot at the end of the post and meets code requirements for structural posts installed in basements or exposed to weather or water splash Material: Varies (see table) Finish: ZMAX® and some in stainless steel; see Corrosion Information, pp. 13-15 Installation: • Use all specified fasteners; see General Notes. • See our Anchoring and Fastening Systems for Concrete and Masonry catalog, or visit strongtie.com for retrofit anchor options. • Post bases do not provide adequate resistance to prevent members from rotating about the base and therefore are not recommended for non -top -supported installations (such as fences or unbraced carports). • Place the base, cut washer(s) or load transfer plate(s) and nut(s) on the anchor bolt(s). Make any necessary adjustments to post placement and tighten the nut securely on the anchor bolt. • See strongtie.com for information on hollow column installation. ABW Place the standoff base and then the post in the ABW and fasten on three vertical sides, using nails or Strong -Drive SD Connector screws — Bend up the fourth side of the ABW and fasten using the correct fasteners 68 ABU Place the standoff base and then the post in the ABU — Fasten using nails or Strong -Drive SD Connector screws or bolts (ABU88Z, ABU1010Z, ABU1212Z — SIDS optional) ABA Place the post in the ABA — Fasten using nails or Strong -Drive SD Connector screws Codes: See p.12 for Code Reference Key Chart Allowable Loads — Beam Installation r— W" 2 load transfer - plates supplied Typical ABWZ Installation Model Nominal Material (ga.) Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads No. Beam Size Base Strap W L H Anchor Nails (160) (100) (160) (100) ABU46Z Double 2x 12 12 39/a 5 7 % (12) 0.162 x 31/2 2,030 8,475 1,820 6,075 ABU46Z 4x 12 12 38/e 5 7 % (12) 0.162 x 3Y2 2,155 9,890 1,850 7,090 ABU46RZ Rough 4x 12 12 4 6 63/4 % (12) 0.162 x 31/2 2,155 9,890 1,850 7,090 ABU66Z Triple 2x 12 10 51/2 5 61/a % (12) 0.162 x 31/2 1,405 12,715 1,165 9,115 ABU66Z 6x 12 10 51/2 5 61/e % (12) 0.162 x 31/2 1,905 12,920 1,640 11,110 ABU66RZ Rough 6x 12 10 6 6 51-e % (12) 0.162 x 31/2 1,905 12,920 1,640 11,110 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern. 2. Downloads may not be increased for short-term loading. 3. Specifier is to design concrete and anchorage for uplift capacity. 4. Beam depth must be a minimum of 71/4". 5. Shims are required for double 2x (1 shim) and triple 2x (2 shims) installations as shown in the Anchorage by Designer illustration. Additional fastening of shim to beam is not required. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. StrongTie Typical ABA44Z Installation Beam must extend W, x 7' x 10" wood past base center structural panel by 6' min. shim each side of j� beam I I (footnote 5) 00 o0 Triple W beam (min.) (footnote 4) ABU66Z Beam Installation S9 UPDATED 06/01/19 ABA/ABU/ABw Adjustable and Standoff Post Bases (cont.) These products are available with For stainless- Many of these products are approved for installation additional corrosion protection. ® steel fasteners, ®I with Strong -Drive® SD Connector screws. For more information, see p.15. see p. 21. See pp. 335-337 for more information. Allowable Loads - Post Installation Strong -Tie Material (ga.) Dimensions (in.) Fasteners Allowable Loads (DF/SP) Model No. Nominal Post Size Base Strap W L H HB Anchor Dia. (in.) Nails (1°') Bolts Uplift Down (100) Code Ref. QtY. (in) Nails Bolts ABA44Z 44 16 16 39/16 3s/a 31ti6 — 1/2 (6) 0.148 x 3 — — 690 — 5,925 ABW44Z 44 16 16 39/s 39/s 21/4 — 1/2 (8) 0.148 x 3 — — 1,005 — 7,180 ABU44Z 44 16 12 39/16 3 51/2 11/4 % (12) 0.162 x 31/2 2 1/2 1,900 2,300 7,570 ABU44RZ Rough 44 16 12 411A6 3 51/4 11/2 % (12) 0.162 x 31/2 2 1/2 1,900 2,300 7,570 ABA44RZ Rough 44 16 16 41ti6 31/a 21�Yi6 — 1/2 (6) 0.148 x 3 — — 655 — 7,215 ABW44RZ Rough 44 16 16 4 41ti6 11�Yi6 — 1/2 (8) 0.148 x 3 — — 835 — 7,180 ABW46Z 46 12 16 39/16 59/16 3 — 1/2 (10) 0.148 x 3 — — 845 — 4,590 ABA46Z 46 14 14 39/s 5-6 31/a — % (8) 0.162 x 31/2 — — 870 — 10,500 ABU46Z 46 12 12 39/16 5 7 2% % (12) 0.162 x 31/2 2 1/2 2,405 2,265 12,520 ABU46RZ Rough 46 12 12 41Ar 5 6s/4 2% % (12) 0.162 x 31/2 2 1/2 2,405 2,265 12,520 ABW46RZ Rough 46 12 16 4 6 21�Yi6 — 1/2 (10) 0.148 x 3 — — 780 — 4,590 IBC, FL, LA ABA46RZ Rough 46 14 14 41Ar 5-6 27/a — % (8) 0.162 x 31/2 — 870 0,695 ABU5-5Z 51/a x 51/s 12 10 51/4 5 61A6 11/4 % (12) 0.162 x 31/2 2 1/2 2,235 2,235 10,570 ABU5-6Z 51/a x 6 12 10 61/a 5 61Ar 11/4 % (12) 0.162 x 31/2 2 1/2 2,235 2,235 10,570 ABA66Z 6x6 14 14 51/2 5% 31/a — % (8) 0.162 x 31/2 — — 850 — 10,245 ABW66Z 6x6 12 14 51/2 59/16 3 — 1/2 (12) 0.148 x 3 — — 1,190 — 12,935 ABU66Z 6x6 12 10 51/2 5 61ti6 11/4 % (12) 0.162 x 31/2 2 1/2 2,475 2,190 18,205 ABU66RZ Rough 6x6 12 10 611A6 5 51�Y16 11/2 5/a (12) 0.162 x 31/2 2 1/2 2,475 2,190 18,205 ABA66RZ Rough 6x6 14 14 6 5-6 27/a — % (8) 0.162 x 31/2 — — 850 — 11,500 ABW66RZ Rough 6x6 12 14 6 6 21�Yi6 — 1/2 (12) 0.148 x 3 — — 1,190 — 12,935 ABW7-7Z 71/a x 71/s 12 14 75/16 7'A6 3 — 1/2 (12) 0.148 x 3 — 840 14,530 ABU88Z 8x8 14 12 71/2 7 7 — (2) % (18) 0.162 x 31/2 — — 2,570 — 22,405 IBC, FL ABU88RZ Rough 8x8 14 12 8 7 7 — (2) % (18) 0.162 x 31/2 — — 2,450 — 19,870 ABU101 OZ 10x10 14 14 91/2 9 71/4 — (2) % (22) 0.162 x 31/2 — — 2,270 — 32,020 ABU101 ORZ Rough 10x10 14 14 10 9 7 — (2) % (22) 0.162 x 31/2 — — 1,830 — 31,650 IBC, FL, LA ABU1212Z 12x12 12 12 111/2 11 71/4 — (2) % (22) 0.162 x 31/2 — — 3,000 — 34,745 ABU1212RZ Rough 12x12 12 12 12 11 7 — (2) % (22) 0.162 x 31/2 — — 3,000 — 34,745 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern. 2. Downloads may not be increased for short-term loading. 3. Specifier is to design concrete and anchorage for uplift loads. 4. ABU products may be installed with either bolts or nails (not both) to achieve table loads. ABU88Z, ABU88RZ, ABU1010Z, ABU1010RZ, and ABU1212Z/RZ may be installed with (8) 1/4" x 3" Strong -Drive® SIDS Heavy -Duty Connector screws (sold separately) for the same table load. 5. For higher downloads, pack grout solid under 1 " standoff plate before installation. Base download on column or concrete, according to the code. 6. HB dimension is the distance from the bottom of the post up to the first bolt hole. 7. Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers. For SCL columns, the fasteners for these products should always be installed in the wide face. 8. Downloads shall be reduced where limited by allowable loads of the post. 9. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. s i o 69 UPDATED 06/01/19 NKH Engineering Project Title: Kossian Remodel nkhengineering.com Engineer: NKH Project ID: 21-003 Project Descr: Printed: 25 JAN 2021, 10:04PM General Footin g File: Posts & Footings.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.1 i DESCRIPTION: New Footing Code References Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Material Properties Soil Design Values fc : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 1.50 ksf fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30 (p Values Flexure = 0.90 Shear = 0.750 Increases based on footing Depth Analysis Settings Footing base depth below soil surface = 0.830 ft Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft Min. Overturning Safety Factor = 1.0 : 1 Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension Add Ftg Wt for Soil Pressure Yes Allowable pressure increase per foot of depth Use ftg wt for stability, moments & shears Yes = ksf Add Pedestal Wt for Soil Pressure No when max. length or width is greater than - ft Use Pedestal wt for stability, mom & shear No Dimensions Width parallel to X-X Axis = 2.17 ft Length parallel to Z-Z Axis = 2.170 ft Footing Thickness = 10.0 in Pedestal dimensions... px : parallel to X-X Axis = in pz : parallel to Z-Z Axis = in Height - in Rebar Centerline to Edge of Concrete... at Bottom of footing = 3.0 in Reinforcing Bars parallel to X-X Axis Number of Bars - 3 Reinforcing Bar Size = # 4 Bars parallel to Z-Z Axis Number of Bars = 3.0 Reinforcing Bar Size = # 4 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads D 3 - # 4 Bars ,r X-X Section Looking to +Z Lr L S Z-Z Section Lookiig to+X W E H P : Column Load = 2.30 2.750 3.440 k OB : Overburden = ksf M-xx = k-ft M-zz = k-ft V-x = k V-z = k S11 NKH Engineering nkhengineering.com Project Title: Kossian Remodel Engineer: NKH Project ID: 21-003 Project Descr: Printed: 25 JAN 2021, 10:04PM General Footing File: Posts & Footings.ec6 g Software copyright ENERCALC, INC. 1983-2020, Build: 12.20.8.17 KW-06012717 DESCRIPTION: New Footing DESIGN SUMMARY 0- • • Min. Ratio Item Applied Capacity Governing Load Combination PASS 0.8933 Soil Bearing 1.340 ksf 1.50 ksf +D+S about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.1244 Z Flexure (+X) 1.033 k-ft/ft 8.305 k-ft/ft +1.20D+1.60S PASS 0.1244 Z Flexure (-X) 1.033 k-ft/ft 8.305 k-ft/ft +1.20D+1.60S PASS 0.1244 X Flexure (+Z) 1.033 k-ft/ft 8.305 k-ft/ft +1.20D+1.60S PASS 0.1244 X Flexure (-Z) 1.033 k-ft/ft 8.305 k-ft/ft +1.20D+1.60S PASS 0.1390 1-way Shear (+X) 10.427 psi 75.0 psi +1.20D+1.60S PASS 0.1390 1-way Shear (-X) 10.427 psi 75.0 psi +1.20D+1.60S PASS 0.1390 1-way Shear (+Z) 10.427 psi 75.0 psi +1.20D+1.60S PASS 0.1390 1-way Shear (-Z) 10.427 psi 75.0 psi +1.20D+1.60S PASS 0.2621 2-way Punching 39.313 psi 150.0 psi +1.20D+1.60S Detailed Results Soil Bearing Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual 1 Allow Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio X-X, D Only 1.50 n/a 0.0 0.6093 0.6093 n/a n/a 0.406 X-X, +D+Lr 1.50 n/a 0.0 1.193 1.193 n/a n/a 0.795 X-X, +D+S 1.50 n/a 0.0 1.340 1.340 n/a n/a 0.893 X-X, +D+0.750Lr 1.50 n/a 0.0 1.047 1.047 n/a n/a 0.698 X-X, +D+0.750S 1.50 n/a 0.0 1.157 1.157 n/a n/a 0,771 X-X, +0.60D 1.50 n/a 0.0 0.3656 0.3656 n/a n/a 0.244 Z-Z, D Only 1.50 0.0 n/a n/a n/a 0.6093 0.6093 0,406 Z-Z, +D+Lr 1.50 0.0 n/a n/a n/a 1.193 1.193 0.795 Z-Z, +D+S 1.50 0.0 n/a n/a n/a 1.340 1.340 0.893 Z-Z, +D+0.750Lr 1.50 0.0 n/a n/a n/a 1.047 1.047 0.698 Z-Z, +D+0.750S 1.50 0.0 n/a n/a n/a 1.157 1.157 0.771 Z-Z, +0.60D 1.50 0.0 n/a n/a n/a 0.3656 0.3656 0.244 Overturning Stability Rotation Axis & Load Combination... Overturning Moment Resisting Moment Stability Ratio Status Footing Has NO Overturning Sliding Stability All units k Force Application Axis Load Combination... Sliding Force Resisting Force Stability Ratio Status Footing Has NO Sliding Footing Flexure Flexure Axis &Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface in2 in2 in2 k-ft X-X, +1.40D 0.4025 +Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.40D 0.4025 -Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+0.50Lr 0.5169 +Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+0.50Lr 0.5169 -Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+0.50S 0.560 +Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+0.50S 0.560 -Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+1.60Lr 0.8950 +Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+1.60Lr 0.8950 -Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+1.60S 1.033 +Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+1.60S 1.033 -Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+0.20S 0.4310 +Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +1.20D+0.20S 0.4310 -Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK S12 NKH Engineering nkhengineering.com Project Title: Kossian Remodel Engineer: NKH Project ID: 21-003 Project Descr: Printed: 25 JAN 2021, 10:04PI General Footin File: Posts & Footings.ec6 g Software copyright ENERCALC, INC. 1983-2020, Build: 12.20.8.17 DESCRIPTION: New Footing Footing Flexure Flexure Axis &Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface in^2 in^2 in"2 k-ft X-X, +0.90D 0.2588 +Z Bottom 0.2160 Min Temp % 0.2765 8.305 OK X-X, +0.90D 0.2588 -Z Bottom 0,2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.40D 0.4025 -X Bottom 0.2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.40D 0.4025 +X Bottom 0,2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+0.50Lr 0.5169 -X Bottom 0.2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+0.50Lr 0.5169 +X Bottom 0,2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+0.50S 0.560 -X Bottom 0.2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+0.50S 0.560 +X Bottom 0,2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+1.60Lr 0.8950 -X Bottom 0.2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+1.60Lr 0.8950 +X Bottom 0,2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+1.60S 1.033 -X Bottom 0.2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+1.60S 1.033 +X Bottom 0,2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+0.20S 0.4310 -X Bottom 0.2160 Min Temp % 0.2765 8.305 OK Z-Z, +1.20D+0.20S 0.4310 +X Bottom 0,2160 Min Temp % 0.2765 8.305 OK Z-Z, +0.901) 0.2588 -X Bottom 0.2160 Min Temp % 0.2765 8.305 OK Z-Z, +0.90D 0.2588 +X Bottom 0,2160 Min Temp % 0.2765 8.305 OK One Way Shear Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu 1 Phi*Vn Status +1.401D 4.06 psi 4.06 psi 4.06 psi 4.06 psi 4.06 psi 75.00 psi 0.05 OK +1.20D+0.50Lr 5.22 psi 5.22 psi 5.22 psi 5.22 psi 5.22 psi 75.00 psi 0.07 OK +1.20D+0.50S 5.65 psi 5.65 psi 5.65 psi 5.65 psi 5.65 psi 75.00 psi 0.08 OK +1.20D+1.60Lr 9.03 psi 9.03 psi 9.03 psi 9.03 psi 9.03 psi 75.00 psi 0.12 OK +1.20D+1.60S 10.43 psi 10.43 psi 10.43 psi 10.43 psi 10.43 psi 75.00 psi 0.14 OK +1.20D+0.20S 4.35 psi 4.35 psi 4.35 psi 4.35 psi 4.35 psi 75.00 psi 0.06 OK +0.90D 2.61 psi 2.61 psi 2.61 psi 2.61 psi 2.61 psi 75.00 psi 0.03 OK Two -Way "Punching" Shear All units k Load Combination... Vu Phi*Vn Vu 1 Phi*Vn Status +1.40D 15.32 psi 150.00osi 0.1021 OK +1.20D+0.50Lr 19.67 psi 150.00PSi 0.1311 OK +1.20D+0.50S 21.31 psi 150.00osi 0.1421 OK +1.20D+1.60Lr 34.06 psi 150.00psi 0.2271 OK +1.20D+1.60S 39.31 psi 150.00osi 0.2621 OK +1.20D+0.20S 16.40 psi 150.00psi 0.1094 OK +0.90D 9.85 psi 150.000si 0.06565 OK S13