REVISION 1 APPROVED BLD-BLD2021-0262+Architectural_Plan+9.3.2021_3.50.39_PM+23932734'-
N7Cn' _ I " n
o
Ln Ln
-1 C REGIVER'S
00
00 BEDROOM
NET = 7 6 SF
_\0
O
c0
O
OFFICE —
LOSID
co 6®
9 , 9/2,. F-- 7
IVAI
I
-- I EXIST. HDR.
BEDROOM VvN� I I TO REMAIN
NS- I NE _±I 15 SF 90 ❑■ 38"
12 HR . TIMH2
II
CV
0
'3 -
_ 5 ,.
HALLWAY
o
CV
NOTE:
CV
FINSH CEILING HT:
±8' FROM FINSH
FLOOR (TYP )
TO MATCH EXIST.
FE <
4 3"
BEDROOM
D2
NS-I N_T=±107 SF
0
Z
A
10' 6/2,.
18'
EF oU
BEDROOM - D 8 BEDROOM - B
BATH
ROOM
0
BEDROOM - C
NOTE:
THERE IS AN EXISTING
V44OLE-NOT ISE FAN
INSTALLED. VERIFY LOCATION
21'- IA"
ELECTRIC HEAT PIJvP
SEISMIC STRAP TO WALL
DRAIN PAN, CCNDB\1SATE OD
___)DRAIN and PRESSURE
W RELIEF VALVE PIPING TO
TERMINATE OUTDOORS
HALLWAY
S�
O WASI-8R E DRYER
TO BE REMOVED
CAPPED ALL PLLWBING
DRAIN E WATER PIPES Sp
I
o`
O (� BEDROOM -A
m
COVERED DECK
p FIRE-EXTINGUISHER
2 -A: 10-BC
TOP OF EXTINGUIISHE 2 = MAX . 5' HIGH
BOT . OF EXTINGUISHER= MIN . 4' FR . THE FLR .
LOCATION: HALLWAY, MUST BE SECURED TO
THE WALL OR INSIDE RECESSED WALL.
* ALL NEW WINDOWS SHALL BE NFRC CERTIFIED
DOORS AND WINDOWS SCHEDULE
MARK
SIZE
TYPE
HARDWARE
REMARKS
D - I
(1) 6068
EXT PIOR DOOR
METAL or FIBERGLASS
LEVER TYPE, INTERCONNECT
DEVICE DOOR HANDLE.
EGRESS
D- 2
(3) 3068
INTERIOR DOOR
NCN-LOCKING LEVER TYPE
6 PANEL
D-3
=2868
INTERIOR DOOR
NON -LOCKING LEVER TYPE
6 PANEL
D-4
(2) 2668
INTERIOR DOOR
DYED DOOR KNOB
6 PANEL
D - 5
(1) 2068
INTERIOR DOOR
DYED DOOR KNOB
6 PANEL
=-6
(2) 4068
INTERIOR BI -FOLD DOOR
PULL KNOB
6 PANEL
W- 1
(2) 5040
VINYL U= . 30
HORIZONTAL SLIDER
w/ "TRICKLE VENT'
EGRESS
W- 2
(I) 4040
VINYL U= . 30
HORIZONTAL SLIDER
w/ "TRICKLE VENT
EGRESS
W - 3
(1) 1840
VINYL U = . 30
SINGLE - H.J\1G
-**INTERCOMECT DEVICE = AN INTERNAL NECHANISM THAT DEACTIVATES TI--E
DEADBOLT LOCK WI -EN THE LEVER IS TURNED TO OPEN THE DOOR. " LEVER DOOR
HANDLE AND DEADBOLT WI -EN IN LOCKED POSITION WILL OPEN SIMULTANEOUSLY
ALLOWING PEOPLE TO EXIT AND RE - ENTER WITHOUT THE USE OF ANY KEY,
TOOL AND OR SPECIAL KNOWLEDGE . "
--------------
DW
KITCI-B\A
DO MIN. 100
CFM VTO
e
DINING
O
PWDR .
ROOM /
MIN. 10
CFM V
0
KITCHEN
0
°❑
0
LIVING ROOM
DINING
❖
PP20POSED SOWER FLOOI� PLAN
EXISTING LIVING SPACE= ±2937 SF SCALE: 1/4"- 1 ' - O"
NEW LIVING SPACE = ±7 20 SF
TO WALKWAY
LEGEND:
0
EXISTING WALL
NEW 2x4 HF=2 INT . WALL
NEW 2x6 HF# 2 EXT . WALL
S.D. ®
SMOKE DETECTOR WIRED
w/ BACK-UP BATTERY
S.D.C.O.
®
SMOKE DETECTOR V'\ARED
w/ CARBCN MONOXIDE and
w/ BACK-UP BATTERY
E,F
EXHAUST FAN (V.T.0.)
W.H.E.F.
}
WHCLE HOUSE EXHAUST FAN
(V.T.0.)
9
WINDOW rnd DOOR SG-EDU_E
a
220v ELECTRIC WALL HEATER
E.W.H.
FAN FORCED w/ HEAT GUARD
E SEPARATE THERMOSTAT
TO DRIVEWAY
£ PARKING
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
REVISED PLAN APPROVED
CITY ODMON�ILDI G ISION
Q(P/ 00
A
BUILDING DFFI JAL
Sep 22 2021 APPROVED DATE
SMALL DWELLING UNIT: 3.0 CREDITS
DWELLING UNITS LESS THAN 1500 SF IN CONDITIONED FLOOR AREA
WITH LESS THAN 300 SF OF FENESTRATION AREA. ADDITIONS TO
EXISTING BUILDING THAT ARE GREATER THAN 500 SF OF HEATED
FLOOR AREA BUT LESS THAN 1500 SF.
20 18 WSEC OiDtion I. 2, 5. 1 E 5. 4
EFFICIENT BUILDING ENVELOPE 1. 21 (1. 0 pts . >
PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE
P402 . 1 . 1 w/ THE FOLLOWING MODIFICATIONS.
VERTICAL FENESTRATION U= . 20
EFFICIENT WATER HEATING OPTIONS 5. 1 , (0. 5 pts . )
A DRAIN WATER HEAT RECOVERY UNIT (S) SHALL
BE INSTALLED, WHICH CAPTURES WASTE WATER
HEAT FROM ALL AND ONLY THE SHOWERS, AND
HAS A MINIMUM EFFICIENCY OF 40% IF INSTALLED
FOR EQUAL FLOW OR A MINIMUM EFFICIENCY OF
54% IF INSTALLED FOP UNEQUAL FLOW . SUCH UNITS
SHALL BE RATED IN ACCORDANCE WITH CSA B55. 1
OR IAMPMO IGC 346 - 2017 AND BE SO LABELED.
EFFICIENT WATER HEATING OPTIONS 5. 4- ( 1. 5 pts . )
WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE
FOLLOWING:
ELECTRIC HEAT PUMP WATER HEATER MEETING THE
STANDARDS FOR TIER I OF NEEA' S ADVANCED
WATER HEATING SPECIFICATION
TABLE R402. 1.1
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT*
CLIMATE ZONE 5 AND MARINE 4
Fenestration U - Factor b
0.30
Skylightb U - Factor
0.50
Ceiling R -Value*
4
Wood Frame Wall g , h R - Value
2 1 int
Floor R - Value
30
Below - Gradec , h Wall R - value
10/ 15/ 2 1 int + 5TB
Slab d , f R - Value E Depth
10, 2 ft
APPROVED
PLANS MUST BE
ON JOB SITE
City of Edmonds
Building Department
APPROVED Plans
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
TABLE M 1507. 3. 3 (1 )
Continuous Whole -House Mechanical Ventilation System Airflow Rate Requirements
NUMBER OF BEDROOMS
Dwelling Unit
Floor Area ( square feet)
0-1
1 2-3
4-5
6-7
7
Airflow in CFM
< 1,500
30 45 60
75
90
1,501 - 3,000
45 60 75
90
105
3,001 - 4,500
60 75 90
105
120
4,501 - 6,000
75 90 105
120
135
6 , 001 - 7 , 500
90 105 120
135
150
7,501
1 105 1 120 1135
1 150
165
For Sh I square foot 0.0929 m2 , I cubic foot per minute 0. 00047 19 m3/S
Table M 1507 . 3 . 3 (2 )
Intermittent Whole -House Mechanical Ventilation Rate Factors a, b
Run - Time Percent ge
in Each 4-Hour Segment
251
33% 50% 66%
75%
100%
Factor - a
4
3 2 1.5
1.3
1.0
NEW ADDITION TOTAL HEATED FLOOR AREA- 720 SO. FT . BEDROO WS, 3-
V%4CLE HOUSE VB�MLAT ICN FAN SIZE - 45 CFM x 2 (50% PB2 4-14OUR) - 90 CFM V . T . O .
1:3��y�iy�iQiy�:3►a
REVISION
Sep 03 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Ei
0LU
zCn
LO LO
W � LO
D0OOWz
U�
wQ
mOoLL
W
.
�W\ CO�wA00
> H CO d'
I- Q
co
OOz7zz(f)a
F-� O Z
QOzz=
w
O "
III w
Q W W LL
�j
W Z
Z Q LL
00 z
W
w
��, � E--;
WOO
0W ~off
CO
z�x0�
a
3WQo
.
LO
��>
0-) LL
ILL>U
w�
owz
a-W�Zzc�yw
O QLO=
Q
CL,zo�
om,C
W�WUO
p-I ��
LJ
0Czcn
I-11
n o CD
<
LU <
` a
<<F--
Q LL
■■■
�zaLULU
z�z m�
■■■
00o0
Q
0 J J Cy Q
OQwFy
W 0LU
�Qz� z
CV
00
ON
(n
0
J
J
O
N
Cn
LU
Cy
W
W
O
11
L�
I
C)
O
O
�
Lo
O\
�
co
>
ICI
U
Z
Q
`0
O
O
Q
=
O
Q
Q
.o
J
�
w
O
O
Z
W
C)
Q
0
J
W
LL
Q
LC)
W
~
W
co
Oco
W
Z_
Q
co
0
~
co
ir—\10
O
X
W
I_W
W
N
C
Ia
00
M
zQ
W
(9
U)
N
LU
W
�
Q
cLU W
p
z
c0
Z
O
co
o..
co
q
o
W
W
CO
W
LU
Z
O
a
0
O
2
Q
REVISIONS,
ADDED NEW WALK - IN
SHOWER ON THE
PROPOSED PWDR . RM .
RELOCATE PROPOSED
STACKABLE WASHER E
DRYER TO NEW
PROPOSED ADDITION
EXISTING BATHROOM
TO BE MODIFIED PER
PROPOSED PLAN SEAL
REMAIN AS IS.
SHEET TITLE,
PROPOSED FLR . PLAN
SCHEDULE OF DOORS
E WINDOWS PER PLAN
WSEC ENERGY CALCS .
TABLE M1507.(3).(3)
DESIGN BY: CNL
DRAWN BY: CNL
CHECKED BY: LYDIA
PROJECT NO,
SCALE -.AS NOTED
SHEET
- 2
DATE,
8-30-2021