Loading...
APPROVED BLD RESUB1 BLD2021-0955+Architectural_Plan+9.8.2021_1.32.33_PM+2397719210TH ST SW - 212TH ST SW SITE PLAN i I I I 7315 212TH ST SW EDMONDS, WA 98026 I �NJ 1/16" = 1'-0" GRAPHICS 4 WALL TYPE NORTH ARROW CASEWORK ELEVATIONS N NUMBER IDENTIFICATION NUMBER IDENTIFICATION DATUM OR BENCH MARK RELITE TYPE ID/A4. 1 1 SHEET NUMBER (A4.1 #) FLOOR ELEVATION NUMBER IDENTIFICATION COLUMN GRID SYMBOLS KEY NOTE SEE LIST OF NOTES ABBREVIATIONS INTERIOR ELEVATIONS NUMBER IDENTIFICATION /AM SHEET NUMBER (A4.#) 1 CLOUD AREA OF REVISION REVISION INDICATOR DETAILS j NUMBER IDENTIFICATION A5.1 SHEET NUMBER (A5.##) r ----�1 l 1 - - - DETAIL PLAN 2 NUMBER IDENTIFICATION A2 0 SHEET NUMBER ACT ACOUSTICAL CEILING TILE FAB FABRICATE LAB LABORATORY ACOUST ACOUSTICAL FAW FLUID APPLIED WATERPROOFING LAM LAMINATE AFF ABOVE FINISHED FLOOR FCIO FURN BY CONTRACTOR, INSTALLED BY OWNER LAV LAVATORY ADJ ADJACENT FD FLOOR DRAIN LB POUND ALUM ALUMINUM FDN FOUNDATION LN LINEAR APROX APPROXMIATE FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR MATL MATERIAL BLDG BUILDING FG FIBERGLASS MAX MAXIMUM BM BEAM FIG FIGURE MECH MECHANICAL FIN FINISHED) MDF MEDIUM DENSITY FIBERBOARD CAB CABINET FIX FIXTURE MEMB MEMBRANE CL CENTER LINE FL FLOOR MFR MANUFACTURER CLO CLOSET FLG FLOORING MIN MINIMUM CLR CLEAR FLS FLASHING MIR MIRROR CO CLEAN OUT FLUOR FLUORESCENT MISC MISCELLANEOUS COL COLUMN FOIC FURN BY OWNER, INSTALLED BY CONTRACTOR MIX MIXTURE CONC CONCRETE FOIO FURN BY OWNER, INSTALLED BY OWNER MTL METAL CONT CONTINUOUS FPRF FIREPROOFING CONTR CONTRACTOR ' OR FT FEET N NORTH CG CORNER GUARD F.T. FIRE TREATED NIC NOT IN CONTRACT CORR CORRUGATED FTG FOOTING NO NUMBER CPT CARPET NOM NOMINAL CU FT CUBIC FEET GA GAGE, GAUGE NTS NOT TO SCALE GB GRAB BAR DEG DEGREE G.C. GENERAL CONTRACTOR OA OVER ALL DET DETAIL GWB GYPSUM WALL BOARD OC ON CENTER DIA DIAMETER OD OUTSIDE DIAMETER DIM DIMENSION HGT HEIGHT OH OPPOSITE HAND DS DOWNSPOUT HM HOLLOW METAL OPNG OPENING DWG DRAWINGS) HOR HORIZONTAL OPP OPPOSITE HR HOUR E EAST HW HOT WATER LB POUND EJ EXPANSION JOINT PART PARTITION EL ELEVATION ID INSIDE DIAMETER PERF PERFORATED ELEC ELECTRIC IN INCH PERM PERMANENT ENM ENAMEL INFO INFORMATION P LAM PLASTIC LAMINATE EQ EQUAL INSUL INSULATION PL PLATE, PROPERTY LINE EQUIP EQUIPMENT INT INTERIOR PNT PAINTED EST ESTIMATE POS POSITIVE EXH EXHAUST JT JOINT PR PAIR XIST EXISTING PREFAB PREFABRICATED EXT EXTERIOR PTD PAPER TOWEL DISPENSER QUAL QUALITY RAID RADIATOR RB RESILIENT BASE RD ROUND RECP RECEPTACLE REQD REQUIRED REV REVISED RCP REFLECTED CEILING PLAN RM ROOM SD SOAP DISPENSER SIM SIMILAR SPEC SPECIFICATION SQ SQUARE SS STAINLESS STEEL STG STORAGE STL STEEL SUB SUBSTITUTE SV SHEET VINYL SW SWITCH TEL TELEPHONE TP TOILET PAPER TYP TYPICAL UL UNDERWRITERS' LABORATORY INC UNO UNLESS OTHERWISE NOTED VCT VINYL COMPOSITION TILE VERT VERTICAL VOL VOLUME VP VENT PIPE W/0 WITHOUT WC WATER CLOSET WD WOOD WP WEATHER PROOF WS WEATHER STRIPPING GENERAL NOTES GENERAL 1. ALL WORK TO BE PROVIDED BY CONTRACTOR UNLESS IT IS SPECIFICALLY NOTED TO BE DONE BY OTHERS. 2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION ABOUT THE PROJECT. SAFETY 1. CODES: CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES IN FORCE AT THE TIME OF CONSTRUCTION. 2. HAZARDOUS MATERIALS: CONTRACTOR TO NOTIFY OWNER AND ARCHITECT IF ANY HAZARDOUS MATERIALS SUCH AS ASBESTOS, LEAD PAINT, PCBs ETC. ARE DISCOVERED DURING DEMOLITION OR CONSTRUCTION. COMPLY WITH ALL APPLICABLE REGULATIONS, LAWS, AND ORDINANCES CONCERNING REMOVAL, HANDLING AND PROTECTION AGAINST EXPOSURE OR ENVIRONMENTAL POLLUTION. 3. SEISMIC BRACING: THE ATTACHMENT OF EQUIPMENT WHICH WEIGHS OVER 400 POUNDS SHALL BE DESIGNED PER SBC SECTION 1621. WORK PRACTICES 1. MATERIALS: ALL MATERIALS ARE ASSUMED TO BE NEW (U.O.N.). 2. SUBCONTRACTOR COORDINATION: CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THEIR SUBCONTRACTORS AND FOR THE SCHEDULING AND COORDINATION OF WORK INDICATED ON THE DRAWINGS TO BE DONE BY OTHERS. 3. LAYOUT: CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO STARTING WORK. NOTIFY ARCHITECT OF ANY DISCREPANCIES DISCOVERED. 4. SERVICE SHUTDOWNS: CONTRACTOR TO NOTIFY THE OWNER (48) HOURS IN ADVANCE OF SERVICE SHUTDOWNS. CONTRACTOR TO OBTAIN THE OWNER AND LANDLORD'S PERMISSION TO SHUTDOWN ANY BUILDING SERVICE. 5. SITE CLEANING: CONTRACTOR TO CLEAN PREMISES AND REMOVE DEBRIS ON A REGULAR BASIS. 6. UNEXPECTED CONDITIONS: CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONDITIONS WHICH ARE UNCOVERED WHICH DIFFER FROM WHAT IS SHOWN ON THESE DRAWINGS. DRAWING SPECIFICITY 1. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY NAIL, SCREW, BOLT AND CONNECTION ETC. REQUIRED TO INSTALL A GIVEN ITEM. THE CONTRACTOR IS TO MAKE REASONABLE ASSUMPTIONS AS TO MISCELLANEOUS ITEMS WHICH ARE REQUIRED TO INSTALL ITEMS NOTED ON THESE DRAWINGS. 2. CONTRACTOR TO PROVIDE NECESSARY BACKING , BLOCKING AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES AND OTHER ITEMS REQUIRING SAME. 3. DIMENSIONS: HORIZONTAL DIMENSIONS ARE FROM FINISHED SURFACE TO FINISHED SURFACE U.O.N. VERTICAL DIMENSIONS ARE FROM TOP OF SLAB U.O.N. DRAWINGS ARE NOT TO BE SCALED. 4. NOT ALL SYMBOLS SHOWN ARE USED. OWNER'S WORK RULES 1. ALL WORK TO COMPLY WITH VMMC'S WORK RULES, REGULATIONS AND REQUIREMENTS. 2. CONTRACTOR TO COMPLY WITH THE REQUIREMENTS OF VIRGINIA MASON'S INFECTION CONTROL RISK ASSESSMENT (ICRA) PLAN. PROJECT TEAM OWNER/OCCUPANT VIRGINIA MASON MEDICAL CENTER 1100 NINTH AVENUE SEATTLE, WA 98101 ATTN: SCOTT TANG EMAIL: SCOTT.TANG@VIRGINIAMASON.ORG PHONE: (206) 341-1650 ARCHITECT SABARCHITECTS 2 NICKERSON STREET, SUITE 200 SEATTLE, WA 98109 PHONE: 206-957-6400 EXT 204 ATTN: HERBERT BAKER E-MAIL: HERBERTB@SABARCH.COM CONTRACTOR MY -WAY CONSTRUCTION - L.L.C. 6855 176TH AVE NE, SUITE B265 REDMOND, WA 98052 PHONE: 206-579-8750 ATTN: MIKE MYERS E-MAIL: MIKEM@MY-WAYCONSTRUCTION.COM PROJECT DATA PROJECT ADDRESS 7315 212TH ST SW SUITE 101/207 EDMONDS, WA 98026 ASSESSORS PARCEL NUMBER: 00566900500600 LEGAL DESCRIPTION: Section 20 Township 27 Range 04 Quarter SW SEATTLE HEIGHTS DIV 4 BLK 005 D-00 - LOTS 6, 7, 8, 9, & 10 BLK 5 SD PLAT LESS E 60FT SD LOT 10 LESS W 60FT SD LOT 10 LESS THE E 60FT OF N1/2 SD LOT 9 &LESS W 120FT OF N1/2 LOT 9 PER PARCEL 1 CITY OF EDMONDS BLA LL-2006-145 AFN 200703055005 PROJECT DESCRIPTION TENANT IMPROVEMENT OF EXISTING OFFICES TO CREATE EXAM ROOMS. WORK INCLUDES DEMOLITION OF EXISTING INTERIOR PARTITIONS, INSTALLATION OF NEW WALLS, DOORS, AND FINISHES. INCLUDES NEW HVAC, PLUMBING AND ELECTRICAL WORK. PERMIT FOR FIRE SPRINKLERS, HVAC, PLUMBING, AND ELECTRICAL WORK WILL BE SUBMITTED SEPARATELY. AUTHORITY HAVING JURISDICTION CITY OF EDMONDS ZONING CG2 CONSTRUCTION TYPE II-B OCCUPANCY B FIRE -PROTECTION FULLY SPRINKLED TOTAL BUILDING AREA FLOOR 1 = 25,330 S.F. FLOOR 2 = 31,028 S.F. TOTAL = 56,358 S.F. TOTAL PROJECT AREA 1,315 SF PARKING THERE IS NO PROPOSED CHANGE TO PARKING. APPLICABLE CODES 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 WASHINGTON STATE ENERGY CODE 2018 INTERNAL FUEL GAS CODE 2018 ICC PERFORMANCE CODE OTHER PERMITS: DESIGN -BUILD CONTRACTORS WILL SUBMIT THE FOLLOWING WORK FOR PERMIT REVIEW. 1. FIRE SPRINKLER DRAWING INDEX ARCHITECTURAL AO.01 GENERAL INFORMATION A1.00 SITE PLAN A1.01 LIFE SAFETY PLAN A1.02 ENLARGED LIFE SAFETY PLAN A2.10 DEMOLITION PLAN A2.20 CONSTRUCTION PLAN -PHASE 1 A2.20 CONSTRUCTION PLAN -PHASE 2 A2.30 CEILING DEMOLITION PLAN -PHASE 1 A2.31 CEILING DEMOLITION PLAN -PHASE 2 A2.40 REFLECTED CEILING PLAN -PHASE 1 A2.41 REFLECTED CEILING PLAN -PHASE 2 A6.10 SCHEDULES A9.01 DETAILS MECHANICAL, ELECTRICAL, PLUMBING GENERAL G1.01 COVER SHEET, LOCATION PLANS AND NOTES GO.02 SYMBOLS AND ABBREVIATIONS GO.03 SPECIFICATIONS MECHANICAL AND ELECTRICAL MEP1.01 SCHEDULES AND DETAILS PHASE 1 MP1.10 SECOND FLOOR MECHANICAL AND PLUMBING PLANS - PHASE 1 E1.10 SECOND FLOOR ELECTRICAL PLANS - PHASE 1 VICINITY MAP NOT TO SCALE S A B Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 0 206 957 6400 206 957 6404 �6692 REGISTERED ARCHITFCT nvuLni �. \ILLI\VI\ STATE OF WASHINGTON PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 SPACE FOR OFFICAL CITY USE ONLY GENERAL INFORMATION SCALE: NOT TO SCALE DRAWN: SNV CHECKED: HHB PROJECT NO: 15015.49 A0001 S A B Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 T 206 957 6400 (�) 206 957 6404 � 6692 REGISTERED ARCHITECT Vi nvuui. r�urvn STATE OF WASHINGTON k 0 PERMIT RESPONSE 07 SEP 2021 ff; PERMIT SET 09 JULY 2021 1Y SITE PLAN NOTES I . INV JI I L VVUrC \. rLHIN rUM REFERENCE ONLY. SITE PLAN 1 NJ NOT TO SCALE VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 SPACE FOR OFFICAL CITY USE ONLY SITE PLAN SCALE: DRAWN: CHECKED: PROJECT NO: NOT TO SCALE SNV HHB 15015.49 Al 000 EDMONDS SCALE: N/A EXAM ROOMS - SECOND FLOOR - COORDINATION PLAN S A B Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 0 206 957 6400 206 957 6404 FIRE PROTECTION NOTES 1. SPRINKLER COVERAGE SHALL BE IN ACCORDANCE 6692 WITH NFPA 13. CHANGES OR MODIFICATIONS TO REGISTERED THE SYSTEM MAY REQUIRE PLANS TO BE ARNITFU SUBMITTED TO THE FIRE DEPARTMENT FOR REVIEW T AND APPROVAL PRIOR TO THE WORK BEING I.VULI.1 I. MILLI\VI\ STATE OF WASHINGTON PERFORMED. 2. THIS PROJECT DOES NOT INVOLVE HAZARDOUS MATERIALS AND DOES NOT AFFECT CONTROL ZONES (SBC 414.2) LIFE SAFETY LEGEND AREA OF WORK -__________- REQUIRED EXIT STAIR KI = 0 PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 SPACE FOR OFFICAL CITY USE ONLY COORDINATION I»_101 SCALE: NOT TO SCALE DRAWN: SNV CHECKED: HHB PROJECT NO: 15015.49 Al 001 EDMONDS SCALE: SCALE: 1 /4" = 1' u L 400000 r4 1 ■ Era_ 24 ' ■ ■ ■ ■ ■ ■ ■ ■ ■ 2 1 ' ■ ■ ■ ■ 2 ■ 6= 1 +2+2 +2+ i 1 +4+2 ' ■ A < 2 ■ ■ ■ ■ ■ ■ 2 2 ■ ■ 1 COMMON PATH OF EGRESS = LESS THAN 100' IN FULLY SPRINKLED BUILDING ■ ACTUAL = 66 FT El 1� EXAM ROOMS - SECOND FLOOR - ENLARGED LIFE SAFETY PLAN OCCUPANT LOADS RM # RM NAME AREA O.L.F. OCC. LOAD 2421A CORRIDOR 98 SF 100 1 2421 B STRESS ECHO 312 SF 100 4 2421 C EXAM ROOM 121 SF 100 2 2421 D TREATMENT ROOM 165 SF 100 2 2421 E EXAM ROOM 121 SF 100 2 2424 OFFICE WORKROOM 88 SF 150 1 2421 ENTRY 224 SF 150 2 2421 F EXAM ROOM 126 SF 100 2 TOTAL CARDIOLOGY SUITE 16 LIFE SAFETY LEGEND 2 OCCUPANT EXITING 0 2' 4' 6' 8' S A B Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 0 206 957 6400 206 957 6404 FIRE PROTECTION NOTES 1. SPRINKLER COVERAGE SHALL BE IN ACCORDANCE 6692 WITH NFPA 13. CHANGES OR MODIFICATIONS TO REGISTERED THE SYSTEM MAY REQUIRE PLANS TO BE ARNITFU SUBMITTED TO THE FIRE DEPARTMENT FOR REVIEW T AND APPROVAL PRIOR TO THE WORK BEING I.VUL1.1 I. MILLI\VI\ STATE OF WASHINGTON PERFORMED. 2. THIS PROJECT DOES NOT INVOLVE HAZARDOUS MATERIALS AND DOES NOT AFFECT CONTROL ZONES (SBC 414.2) LIFE SAFETY LEGEND AREA OF WORK -__________- REQUIRED EXIT STAIR KI = LIFE SAFETY NOTES 1. EXISTING EXIT PATHS WITHIN AND FROM BUILDING ARE UNCHANGED EXCEPT FOR AREAS IN AREA OF WORK 2. SEE GENERAL NOTES ON A2.20 FOR NOTES REGARDING THIS PLAN INCLUDING DIMENSIONS, ETC. 3. ALL SPACES ARE GROUP-B OFFICE U.N.O. 4. THE TOTAL OCCUPANT LOAD FOR THIS FLOOR IS 16 (REFER TO THE OCCUPANT LOAD CALCULATIONS, THIS SHEET). PER THE ADJACENT LIFE SAFETY PLAN, THE STAIRWAY DOORS WILL NEED TO ACCOMMODATE 1 OCCUPANTS AND SINCE THE EXISTING BUILDING IS SPRINKLERED AND ALARMED (INCLUDING VOICE ALARM) THE EGRESS CAPACITY OF THE STAIR WOULD BE .2" PER OCCUPANT REQUIRING A CLEAR WIDTH OF 16.5". THE EXISTING DOORS ARE 36". 0 PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 SPACE FOR OFFICAL CITY USE ONLY LIFE SAFETY , W12,, SCALE: NOT TO SCALE DRAWN: SNV CHECKED: HHB PROJECT NO: 15015.49 Al 002 �J Sol■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■son S A B Architects ■ EDMONDS SCALE: 1 /2" = 1' CARDIIOLOGY SUITE - DEMOLITION PLAN FE_ DEMOLITION PLAN LEGEND � ------ EXISTING WALLS AND DOORS ■ TO BE REMOVED. ■ ■ DEMOLITION PLAN KEY NOTES ■ ■ 1. REFER TO CONSTRUCTION PLAN TO VERIFY EXTENT OF DEMOLITION 2. DEMO EXISTING FLOOR FINISH IN PREPARATION FOR NEW FLOOR. ■ 3. PATCH WALL, ETC AS NEEDED DUE TO ■ DEMOLITION AS NEEDED TO RECEIVE NEW ■ PAI NT. 4. DEMO EXISTING CEILING TILES. EXISTING ■ CEILING GRID TO REMAIN. REPLACE THE TILES ■ AS SPECIFIED IN THE FINISH LEGEND ON ■ DRAWING A2.20. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS REGARDING POSSIBLE GRILL OR LIGHT FIXTURE MODIFICATION. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 1 0 1 ' 2' 3' 4' 2 Nickerson ST Suite 200 Seattle, WA 98109 (�) 206 957 6400 (�) 206 957 6404 �6692 REGISTERED ARCHITECT 77 I\VULI\I I. VILLIVVI\ STATE OF WASHINGTON PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 SPACE FOR OFFICAL CITY USE ONLY DEMOLITION aw_1ff SCALE: 112 " = 1 '-0" DRAWN: SNV CHECKED: HHB PROJECT NO: 15015.49 A201 0 ■■■■■■■■■,■■■■■■■■■■■■■■■■■■o■®NINE ■■II■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ � I I � � I � I I � I I 2421 B 39-099 O �01 �J I \ 0 ^I I 11 � A9.01 �I o � I N STRESS ECHO 421B 312 SF BRACKETS AND STANDARDS 21 ' -10 3/4" CURTAIN TRACK $ 14 6 /4rchltects 2 Nickerson ST Suite 200 FLOOR PLAN KEY NOTES Seattle, WA 98109 1. P-1 ON ALL WALLS, TRIM, DOORS U.N.O. O 206 957 6400 2. FOR ADDITIONAL SYMBOLS AND (0)206 957 6404 ABBREVIATIONS SEE DRAWING A0.01. 3. FOR WALL INFORMATION SEE DRAWING A9.01. 4. PROVIDE WALL BACKING AT CASEWORK 6692 REGISTERED AND OVERHEAD SHELVING LOCATIONS AS ARrHrrFrT REQUIRED. T 5. PROVIDE MOISTURE RESISTANT CEMENTITIOUS BOARD AT ALL WET AREAS. STATE OF WASHINGTON 6. REFER TO A9.01 FOR TYPICAL MOUNTING HEIGHTS. CONSTRUCTION PLAN LEGEND EXISTING WALLS Rq-EEQUIPMENT TAG, REFER TO EQUIPMENT SCHEDULE ELEVATION TAG Z� PERMIT RESPONSE 0/A PERMIT SET NEW WALL TYPE PARTITION A UNO. REFER TO NOTE #2 AREA OUTSIDE OF SCOPE 07 SEP 2021 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 F L SPACE FOR OFFICAL CITY USE ONLY CONSTRUCTION PLAN SCALE: DRAWN: CHECKED: PROJECT NO: 112" = V-0" SNV HHB 15015.49 A2020 EDMONDS CARDIOLOGY SUITE - CONSTRUCTION PLAN - PHASE 1 SCALE: 1 /2" = 1' 0 1' 2' 3' 4' r./ EXAM o ROOM I 421 N 126 SS 6, 8 1 /299 4'- 1 1/2 )) `1 ■ CORRIDOR A im 98 SF 421 ■ ■ ■ z ■ ■ < ■ BUILT-IN ■ WORKSTATION i BRACKETS EXAM ■ BUILT-IN ■ WORKSTATION BRACKETS AND ROOM ■ AND STANDARDS 421 C STANDARDS 12 ' SF ■ ENTRY --- ■ ■ 2421 I I ■ 224 SF ■ ■ ■ ■ ■ I I I ■ I I I ■ ■ Q I I ■ TREATMENT ■ ROOM ■ 0ZD 165 SF ■ L---------- EXJAM L----------- J 16'-10 1/4" ■ OFFICE ROOM i ■ ■ WORKROOM 421 0 ■ 2424 121 SF 13 A9.01 88 SF ■ ■ ■ ■ 0 FLOOR PLAN KEY NOTES 1. P-1 ON ALL WALLS, TRIM, DOORS U.N.O. 2. FOR ADDITIONAL SYMBOLS AND ABBREVIATIONS SEE DRAWING A0.01. 3. FOR WALL INFORMATION SEE DRAWING A9.01. 4. PROVIDE WALL BACKING AT CASEWORK AND OVERHEAD SHELVING LOCATIONS AS REQUIRED. 5. PROVIDE MOISTURE RESISTANT CEMENTITIOUS BOARD AT ALL WET AREAS. 6. REFER TO A9.01 FOR TYPICAL MOUNTING HEIGHTS. CONSTRUCTION PLAN LEGEND EXISTING WALLS EQ-10 EQUIPMENT TAG, REFER TO EQUIPMENT SCHEDULE ELEVATION TAG NEW WALL TYPE PARTITION A UNO. REFER TO NOTE #2 AREA OUTSIDE OF SCOPE S A 6 Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 (�) 206 957 6400 (�) 206 957 6404 �6692 REGISTERED ARCHITFrT STATE OF WASHINGTON 0 PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 S SPACE FOR OFFICAL CITY USE ONLY CONSTRUCTION PLAN - PHASE 2 SCALE: 112" = V-0" DRAWN: SNV CHECKED: HHB PROJECT N0: 15015.49 A2021 EDMONDS SCALE: 1 /2" = 1' CARDIOLOGY SUITE - CONSTRUCTION PLAN - PHASE 2 0 1 ' 2' 3' 4' LL- $%%IMM 0 sons SENSES MEESE SEEMS SEEMS SENSES MEESE SEEMS SENSES MEESE SEEMS SENSES NONE NONE sons 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ■ � ♦ —.......... I .—................. . . . . 7— -T ------------ I .—.................. . . . 7— I I I I I �� I I I I AR I I\ /I I I\ /I ■ ■ ■ ■ I I I \\ /' I I I \\ /' I I I \/ I \/ I I I /\ I I I /\ I ■ ■ ■ I I I / \\ I I I // \\ I n I/ \I I I/ \I t ---- I\ /I I\ /I ■ ■ ■ I \� /� I I \/ I I \� I \/ I I L------1--------------1- ■ I/ \ I I/ \ I I I I I ■ SKYU GHT I\ /I I\ �I ■ ■ ■ ■ ■ \/ I /\ I ■ ■ I / \ I I/ \I ■ ■ ■ I\ /I I\ �I I\ /I I\ �I I\ /I I\ /I I\ /I I\ �I ■ ■ ■ I\ � I I \ � I I \/ I I\ � I I \ � I I \/ I I\ / I I \ / I I \/ I I\ � I I \ � I \/ I ■ ■ ■ I/ \ I I/ \I I/ \I I/ \ I I/ \I I/ \I I/ \ I I/ \I I/ \I I/ \ I I/ \I I/ \I ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ i ■ ■ ■ ■ F7 V) CEILING DEMOLITION NOTES 1. REFER TO REFLECTED CEILING PLAN AND DETAILS 7&8/A9.01 FOR "SOFFITS" WHERE PARTITION WALLS HAVE BEEN REMOVED. CEILING DEMOLITION LEGEND II II (Jl II II L=J II II Fr-- = II II L=J EXISTING RECESSED LIGHT FIXTURES. SEPERATE ELECTRICAL SUBMITTAL TO VERIFY. DEMO LIGHT FIXTURES. REFER TO RCP SHEET A4.04 FOR POSSIBLE REUSE $ /A B /Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 (�) 206 957 6400 (f) 206 957 6404 �6692 REGISTERED AR('HITF(T I\VULI\I I. VILLIV VI\ STATE OF WASHINGTON 0 PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 EXISTING 2'X4' ACT CEILING DEMO 2'X4' ACT CEILING VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 L J SPACE FOR OFFICAL CITY USE ONLY DEMOLITION REFLECTED CEILING PLAN SCALE: DRAWN: CHECKED: PROJECT NO: 1/2" = V-0" SNV HHB 15015.49 A2m3O EDMONDS SCALE: 1 /2" = 1' EXAM ROOMS — SECOND FLOOR — REFLECTED CEILING DEMOLITION PLAN — PHASE 1 0 1 ' 2' 3' 4' 0 %%sons NONE NONE NONE NONE NONE NONE NONE 0 NEI MEESE SEEMS NEI NEI MEMO MEESE MEESE SEEMS SENSES MEESE SEEMS SENSES MEESE M SENSES MEESE MMIv■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ j ■4x/l ■ ■ ■ ■ ■ ■ ■ I\ /I I\ /I I\ /I I\ /I ■ ■ ■ I \ / I I \ / I \/ I \ / I I \ / I I \/ ■ ■ ■ I / \ I I / \ I �/' \\1 SKYU GHT I / \ I I / \ I I/' \\1 ■ ■ ■ ■ ■ ■ El ■ ■ ■ I\ /I I\ /I I\ /I I\ /I ■ ■ ■ I \ / I I \ / I \/ I \ / I I \ / I I \/ ■ ■ I/ \I I/ \I I/ \I I/ \I ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ I\ /I I\ I\ /I I\ /I I\ /I I\ /I I\ /I ■ ■ ■ I\/ I \/ I\/ I \/ I\/ I \/ I\/ I \/ I\/ I \/ I\/ I \/ ■ ■ I I I '\ I I'\ I I I I '\ I I'\ I I I I '\ I I'\ I I I I '\ I I'\ I I I I '\ I I'\ I I I I '\ I I'\ I ■ ■ ■ I/ \I I/ \I I/ \I I/ \I I/ \I I/ \I I/ \I I/ \I I/ \I I/ \I I/ \I I/ \I ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ I\ /I I\ /I I\ /I I\ /I I\ /I I\ /I I\ /I I\ /I ■ I \' I \' I I \/ ■ ■ ■ ■ I/\ I I/ \ I I/ \I I/ \I I/\ I I/ \ I I/ \I I/ \I I/\ I I/ \ I I/ \I I/ \I I/\ I I/ \ I I/ \I I/ \I ■ ■ 4411■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■ ■■■■ ■■■■■ ■■■■■■ ■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■�� V) CEILING DEMOLITION NOTES 1. EXISTING CEILING GRID TO REMAIN UNO. INSTALL NEW CEILING TILES. CEILING DEMOLITION LEGEND II II (Jl II II L=J II II II II L=J EXISTING RECESSED LIGHT FIXTURES. SEPERATE ELECTRICAL SUBMITTAL TO VERIFY. DEMO LIGHT FIXTURES. REFER TO RCP SHEET A4.04 FOR POSSIBLE REUSE EXISTING 2'X4' ACT CEILING AREA $ /A B /Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 (�) 206 957 6400 (f) 206 957 6404 �6692 REGISTERED AR('HITF(T VY I\VULI\I I. VILLIV VI\ STATE OF WASHINGTON 0 PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 L J SPACE FOR OFFICAL CITY USE ONLY DEMOLITION REFLECTED CEILING PLAN SCALE: DRAWN: CHECKED: PROJECT NO: 112" = V-0" SNV HHB 15015.49 A2m31 EDMONDS SCALE: 1 /2" = 1' EXAM ROOMS - SECOND FLOOR - REFLECTED CEILING DEMOLITION PLAN - PHASE 2 0 1 ' 2' 3' 4' 0/ ■■toISi "■ANZE■■■ ■■■■■■■■MIMI0■jw"0■ximm■MIMES ■, _M_M0Ex-■ m0011-■E■■1-■-amEMI - ■■0■110 1 RCP PLAN NOTES GENERAL 1. PROVIDE SEISMIC BRACING AT ALL ACOUSTIC TILE CEILINGS PER DETAIL 6/A9.01. LIGHT FIXTURES 1. SEE ELECTRICAL DRAWINGS FOR EXACT LIGHT FIXTURE SPECIFICATIONS. SEPERATE SUBMITTAL BIDDER -DESIGN. RCP ISSUES RELATED TO MECH., PLUMB. AND ELEC. 1. SEE MECHANICAL DRAWINGS FOR DIFFUSER AND RETURN GRILLE LOCATIONS AND INFORMATION AND OTHER TECHNICAL INFORMATION. SEPERATE SUBMITTAL BIDDER -DESIGN. 2. CONTRACTOR'S SPRINKLER SUB -CONTRACTOR TO COORDINATE SPRINKLER HEAD LOCATIONS WITH THIS CEILING LAYOUT. RCP PLAN LEGEND $ /4 B /4rchltects 2 Nickerson ST Suite 200 Seattle, WA 98109 (�) 206 957 6400 (f) 206 957 6404 �6692 REGISTERED AR('HITF(T I\VULI\I I. VILLIV VI\ STATE OF WASHINGTON PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE EXISTING RECESSED LIGHT FIXTURES 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 NEW OR REINSTALLED RECESSED LIGHT FIXTURES EXISTING 2'X4' ACT CEILING PATCH AND REPLACE AS NECESSARY TO MATCH EXISTING NEW ACT CEILING ASSEMBLY AREA OUTSIDE OF SCOPE L J SPACE FOR OFFICAL CITY USE ONLY REFLECTED CEILING PLAN SCALE: DRAWN: CHECKED: PROJECT NO: 112" = 1'-0" SNV HHB 15015.49 A2.40 EDMONDS SCALE: 1 /2" = 1' EXAM ROOMS - SECOND FLOOR - REFLECTED CEILING PLAN 0 12' 3' 4' ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SKYU GHT ■ ■ ■ ■ ■ ■ ■ ■ /Iolo ■ ■ ■ ■ ■ ■ At / / / / / / / / / / / / RCP PLAN NOTES GENERAL 1. PROVIDE SEISMIC BRACING AT ALL ACOUSTIC TILE CEILINGS PER DETAIL 6/A9.01. LIGHT FIXTURES 1. SEE ELECTRICAL DRAWINGS FOR EXACT LIGHT FIXTURE SPECIFICATIONS. SEPERATE SUBMITTAL BIDDER -DESIGN. / RCP ISSUES RELATED TO MECH., PLUMB. AND ELEC. 1. SEE MECHANICAL DRAWINGS FOR DIFFUSER AND RETURN GRILLE LOCATIONS AND INFORMATION AND OTHER TECHNICAL / INFORMATION. SEPERATE SUBMITTAL BIDDER -DESIGN. 2. CONTRACTOR'S SPRINKLER 1 SUB -CONTRACTOR TO COORDINATE SPRINKLER HEAD LOCATIONS WITH THIS CEILING LAYOUT. RCP PLAN LEGEND EXISTING RECESSED LIGHT FIXTURES NEW OR REINSTALLED RECESSED LIGHT FIXTURES EXISTING 2'X4' ACT CEILING PATCH AND REPLACE AS NECESSARY TO MATCH EXISTING NEW ACT CEILING ASSEMBLY AREA OUTSIDE OF SCOPE $ /A B /Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 (�) 206 957 6400 (f) 206 957 6404 �6692 REGISTERED AR('HITF(;T I\VULI\I I. VILLIV VI\ STATE OF WASHINGTON 0 PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 L J SPACE FOR OFFICAL CITY USE ONLY REFLECTED CEILING PLAN - PHASE 2 SCALE: 112" = V-0" DRAWN: SNV CHECKED: HHB PROJECT NO: 15015.49 A2.41 EDMONDS EXAM ROOMS - SECOND FLOOR - REFLECTED CEILING PLAN - PHASE 2 SCALE: 1 /2" = 1' 0 1 ' 2' 3' 4' DOOR SCHEDULE DOOR FRAME NUM ROOM NO. ROOM NAME DOOR SIZE REQ FIRE TYPE THCK MAT FIN GLAZ TYPE MAT FIN HW GRP COMMENTS W X H RATING 2421A CORRIDOR EXISTING 2421 B 2421 B STRESS ECHO 3'-0" X 7'-0" N/A D1 1-3/4" WD NOTE 2 F1 HM PT NOTE 3 NOTE 1 2421C 2421C EXAM ROOM 3'-0" X 7'-0" N/A D1 1-3/4" WD NOTE 2 F1 HM PT NOTE 3 2421 D 2421 D TREATMENT ROOM 3'-0" X 7'-0" N/A D1 1-3/4" WD NOTE 2 F1 HM PT NOTE 3 2421 E 2421 E EXAM ROOM 3'-0" X 7'-0" N/A D1 1-3/4" WD NOTE 2 F1 HM PT NOTE 3 2424 OFFICE WORKROOM EXISTING 2421 ENTRY EXISTING 2421 F 2421 F EXAM ROOM 3'-0" X 7'-0" N/A D1 1-3/4" WD NOTE 2 F1 HM PT NOTE 3 NOTE 1: REUSE DOOR /FRAME ASSEMBLY FROM 2421 NOTE 2 MATCH EXISTING NOTE 3 BLDG. STD ADA COMPLIANT HARDWARE DOOR FRAMES AND TYPES DOOR TYPES i i D1 F1 No U�Col S A B Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 O 206 957 6400 0206 957 6404 �6692 REGISTERED ARC:HITF(T I\VULI\I I. VILLIVVI\ STATE ❑F WASHINGTON Z� PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE SUITE 207 EDMONDS, WA 98026 I I L SPACE FOR OFFICAL CITY USE ONLY SCHEDULES AND FINISH LEGEND SCALE: NOT TO SCALE DRAWN: SNV CHECKED: HHB PROJECT NO: 15015.49 A601 0 1 PAPER TOWEL AND SOAP DISPENSERS LL52 WEST SCALE: 1/2" = 1'-0" i o i \ N \ / 1'-6" 1 2'-6" TYP MOUNTING HEIGHT -HAND SINK 9 SCALE: 3/4" = 1'-0" iN PARTITION WALL 8" GWB 5/8" STUDS, TYP. rT INSULATION RNER BEAD, TYP. NOTES: 1. LATERAL FORCE BRACING: LATERAL FORCE BRACING SHALL BE 12'-0" O.C. (MAXIMUM) AND BEGIN NO FARTHER THAN 6'-0" FROM WALLS. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. SPLAY WIRES ARE TO BE (4) 12 GAGE WIRES ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 90° FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE CEILING. SPLAY WIRES ARE TO BE WITHIN 2 INCHES OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. 2. VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEMS AND THE STRUCTURE ABOVE. THE VERTICAL STRUT MAY BE EMT CONDUIT, METAL STUDS OR A PROPRIETARY COMPRESSION POST. (SEE BELOW) EMT CONDUIT 1/2" EMT CONDUIT UP TO 6'-0" 3/4" EMT CONDUIT UP TO 8'-6" 1" EMT CONDUIT UP TO 10'-0 1 METAL STUD 1 5/8" METAL STUD (25 GAGE) Uf- TO &'-2" 2 1/2" METAL STUD (25 GAGE) UP TO 10 4" 3. WALL MOLDINGS (PERIMETER CLOSURE ANGLES) ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2 INCHES WIDE, UNLESS ALTERNATE METHODS ARE APPROVED PRIOR TO INSTALLATION BY THE LOCAL BUILDING DEPT. AND THE DESIGNER OF RECORD. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE WALL MOLDING, THE OTHER END SHALL HAVE A 3/4" CLEARANCE FROM THE WALL AND FREE TO SLIDE. THE GRID SHALL BE ATTACHED AT TWO ADJACENT WALLS (POP RIVETS OR APPROVED METHOD). THERE SHALL BE A MINIMUM 3/4" CLEARANCE FROM THE END OF THE GRID SYSTEM AT UN —ATTACHED WALLS. 4. SPREADER (SPACER) BARS OR OTHER MEANS APPROVED BY LOCAL BUILDING DEPT. SHALL BE USED TO PREVENT THE ENDS OF THE MAIN BEAMS AT PERIMETER WALLS FROM SPREADING OPEN DURING A SEISMIC EVENT. PERIMETER WIRES SHALL NOT BE IN LIEU OF SPREADER BARS. WIRE TYING IS AN ACCEPTABLE ALTERNATIVE TO SPREADER BARS. SPREADER BARS ARE NOT REQUIRED IF A 90° INTERSECTING CROSS OR MAIN IS WITHIN 8" OF THE PERIMETER WALL. 5. HANGER (SUSPENSION) AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED. HANGER WIRES SHALL BE 12 GAGE AND SPACED 4 FEET ON CENTER OR 10 GAGE SPACED 5 FEET ON CENTER. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 LBS. 7. BRACE LIGHT FIXTURE AS PER IBC STANDARDS. SUSPENDED CEILING DETAIL V %SCALE: 3" = 1'-0" BOTTOM OF EXISTING FLOOR DECK METAL BRACING PER DETAIL 6/A9.01 5/8" G.W.B. BOTH SIDES, SMOOTH FINISH EXTEND TO 6" ABOVE CEILING. ACOUSTICAL BATT INSULATION EXTEND TO 6" ABOVE CEILING. 3 5/8" 20 GA. MTL. STUDS @ 16" O.C. WALL BASE, MATCH EXISTING FINISH AS SCHEDULED RES 1 - LATERAL FORCE BRACING AND SPLAY WIRE SEISMIC CATAGORY "C" WALL CLIP MAX. 8" SPREADER BAR OR OTHER SUITABLE SYSTEM REQUIRED WALL TO KEEP PERIMITER COMPONENTS FROM SPREADING ® ® APART ® ALL WIRE TIES ARE TO BE 3„ ° ° THREE TIGHT TURNS AROUND $ MIN. ° ITSELF WITHIN THREE INCHES. 7/8" AT UNATT TWELVE GAGE HANGER WIRE ° e O SPACES 4 FOOT ON CENTER ° ° 2 - WALL MOLDING it 11 COLUMN FRAMING DETAIL 7 PARTITION TYPE C - NOT RATED 3 PARTITION SCALE: 1 1 0 COLUMN DETAILS SCALE: 1 1 /2 1 0 5CALE: 1 1/2 I'-011 METAL BRACING PER DETAIL 3/A9.02 BOTTOM OF EXISTING FLOOR DECK NOTE: PROVIDE DIAGONAL BRACING TO EXISTING FLOOR DECK ABOVE AS REQUIRED TO WITHSTAND 5 P.S.F. LATERAL FORCE. METAL TRACK NEOPRENE GASKET— BOTH SIDES TO SEAL ALL GAPS 1 /4" DIA. BOLTS W/ TUBE SLEEVE TO PROTECT ACT. 5/8" G.W.B. BOTH SIDES, SMOOTH FINISH ACOUSTICAL BATT INSULATION W/ 1" AIR GAP 3 5/8" 20 GA. MTL. STUDS @ 16" O.C. WALL BASE PER FINISH SCHEDULE TYPE A - NON -RATED 5/8" GYPSUM WALLBOARD (GWB), SCREW ATTACHED VERTICALLY WITH FASTENERS 8"O.C. AT EDGES AND 12" O.C. IN THE FIELD OF THE BOARD TO 3-5/8" STEEL STUDS SPACED MAXIMUM 24" O.C. WITH JOINTS STAGGERED ON OPPOSITE SIDES OF THE UL WALL. DESIGN. �1PARTITION TYPE B '\.7J SCALE: 1-1/2" = 1'-0" BOTTOM OF EXISTING FLOOR DECK CONTINUOUS METAL TRACK ANCHOR TO STRUCTURE W/POWER DRIVEN FASTENINGS OR NAIL —INS FOAM TAPE 5/8" TYPE—X GWB BOTH SIDES 3" ACOUSTICAL BATT INSULATION CONTINUOUS STEEL TRACK ANCHORED TO FLOOR @ 2'-0" O.C. 3-5/8" 20 GA. MTL STUDS @ 24" O.C. WALL BASE PER FINISH SCHEDULE FLOOR PER FINISH SCHEDULE RATING VALUE STC 49 S A B Architects 2 Nickerson ST Suite 200 Seattle, WA 98109 0 206 957 6400 0 206 957 6404 � 6692 REGISTERED ARCHITFrT vi nvuuv I. tILLI\VI\ STATE OF WASHINGTON z�, PERMIT RESPONSE 07 SEP 2021 PERMIT SET 09 JULY 2021 VM EDMONDS CARDIOLOGY SUITE 7315 212TH STREET SUITE 207 EDMONDS, WA 98026 F SPACE FOR OFFICAL CITY USE ONLY DETAILS SCALE: VARIES DRAWN: SNV CHECKED: HHB PROJECT NO: 15015.49 A9001