Loading...
APPROVED BLD Resub4 BLD2021-0959+Architectural_Plan+9.30.2021_8.41.13_PM+2439308RECEIVED Oct 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT There is no Plumbing permit associated with this application/permit at this time. Should plumbing be a part of the scope of work. A Plumbing permit will need to added to this project. Driveway APPROVED PLANS MUST BE ON JOB SITE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department --------------------------------------------------- Work GARAGE CONVERSION Address 19500 84TH AVE W Owner HUGHES Approved Date 10/04/2021 Building Official asLawmiL c W. If c4kmm Permit Number; BLD2021-0959 Project Info Phil & Christina Hughes 19500 84th Ave W Edmonds WA. 98026 Garage Conversion Convert existing garage to living space, Cutting in 3 openings in existing walls of kitchen and stairwell. Stud in Existing garage door with; Installing 6/0x4/0 window on south wall, removing 5/0 slider on north wall and installing a 5/Ox3/0 slider. 2x6 PT sill and 2x6 studs @ 16" on center Removal of oil tank, oil furnace and all existing ductwork. Installation of Heat pump/AC mini split system Air Seal & Insulate with R-21 Batts as per 2018 WSEC Square Footage Window U value is 0.29 New HVAC System is IS- 17/8 Main Floor 1668sgft Exterior walls R-Value 21 exposed wall Mitsubishi Heat Pump: Multi Head Mini Split Basement 765sgft Ceiling R-49 exposed ceiling Mitsubishi: MXZ4C36NA-U 1 Head unit Detached Garage 576sgft Floor is Slab on grade (existing) 5- GL Series Heads Rear Deck 189sgft Insulate existing slab with 2x4 sleepers 2' OC MSZGL06NA-U1 R-7.5 Rigid foam Insulation 2- MLZ-KP18NA-U1 TOTAL SQ FT 2910 3.4" plywood subfloor, Ceiling Units Emil vapor barrier 2- MXZ4C36NA-1 outdoor units GARAGE CONVERTING TO I _ NEW WINDOW Family/Media Room 61F RDOR 0.29 Smoke/CO Detector ATTIC ACCESS 9•-9114" F Existing opening Opening M Into Existing all 6• 2 5/16" .1 It n strap ye dtoexlstmq framm4•x1W Header st pile q wl11s. Removal of..Wing sliding door Double 2x4 trimmers oneach entl POWDER NEW WS Ow hl- 2- P1 Finish openinglox 3"rsze 100" G x 46' Supports to %oar below ENTRY UFACTOR 0.29 concrNe slab x NOOK ^ " _ Opening cut into Existing well 4•x13•41 Fir Header Strapped to existing framing "'slmpson strap Double 2x4 trimmers on each eW s10v 3' Structural screws F � Finish opening Sire 308"x 06' -9 J 1 O-ete Foundation wall below ATFIC ACCESS O CD a t STAIRS TO BASEMENT t Heat amp E-Ii, aped rg (L 15"x38•• r, Coned 2x4 wall on Concrete slab below F 1 CD 12'.11 1/2" ( into Existing wall 11'-2 Sld" 4-2-cut 5b."liho Fir Header f- Strapped M existing framing e. Simpson strap s5 on each entl 5moke;'.0 Detector Double2Sh- 410x 3' S[mctural screws .I Finish opening size 308'x ai" 12'-111 ]Il6" LIVING ROOM KITCHEN Mini Split Head Unit Ceiling Mount Heat Pomp mov- 15"x38" - - k 171. -- l�-_-. ---i�-�r- - - - - - -`- WSEC 2018 Requirements for >500 Sgft additions Insulation requirements prescriptive compliance based on Table R402.1.1 Master bedroom FeationUFactor U-29 Window Schedule Ceiling R-49 Wood Frame Wall R-21 Mark k Size Description Count Notes Slab R-value Footnote (f) R-7.5 1 6'-0" X 4'-0" 6'-0" X 4'-0" Sliding Window y4• PIWotbd Subli00r 2 5'-0" X 3'-0" 5'-0" X 3'-0" Sliding Window i r a 4 - i-7.5 d Rgid Insulation 2r4 PT Sleepers �2a'06. mak wlween%1e510epers 2018 Washington State Fnergy Cµde - nesitlennol Prescrlptive Energy Code tam 7-sin Washington Single Family- IN. &Addhl.ns jefFearve eeorwry 1, 2021) ve�e•✓r to These requirements apply to all IRC building types, including detached one -and two-family dwellings and multiple single-family dwellings (townhouses). r ]ece ln)gmadon ln/.rm Phil 8 Chriatina H Davitl Start 18500 84th Ave W Etlrtwnde WA 206A23Ei6W Instructions: This single-family project will use the requirements of the Prescriptive Path below and orporate the minimum values listed. Sated on the size of the stru -, the appropriate number of additional credits are checked as chosen by the permit applicant. Provideall informationfrom chefall.wingtablesas building permitdr wings Table R402.1-Insu1-th s! Fenestration Requirements by Component Table R406.2 -Fuel Normalixatlon Credits and 406.3- Energy Credits. Author dAa,pnse.W to IOTI3O2021 ) All tllmate Zones (Table R402.1.1) -value• - U-hazer• u-Factor° ./a 030 SenleshtaU-Factor ° Gk e a lazed Fenestration SHGC °•` n/a n /a WelFrame ling ` 49 0.�6 Wood W all de- 21 int0_O56 Boor 3O O0.0299 ¢low Grade W.Il-' 30/15/21 int. TS Slab °^ R-value & Depth- 30, 2 ft n%a R-values are minimums. U--ts and SHGCare maximums. When insulation m installed in a cavity Mat Is less than the label or designthickness of Me ,nsulation, the compressed R-value of Me insulation from Appendix Table A301.4 snail not be less Man the R-value speclfietl in the table. b The fenestration U-factor column excludes skyllgntz. "10/1S/21-8" means 1 -30 continuous insulation on the ertedor of the wall, or R-15 continuous insulation on the Interior of the wall, or R-21 cavity Insulation plus a thermal break between 1HI slab -the basement wall at r of Me basement wall. "lO/15/21 aSTB" shall be permittetl to be met1 R- , fth. insu anon o ns R'rof th11 11,en[wallf R-Scontidb insulation anthe interiorora#Briar ofthe wall'"STS"n S thermal break between floor slab and basement wall. a Rao..nenpopa maplatlon Is regwrea pneer neared dab on grace noors. see xai.n Raoz.z. single rafrer- or (Dirt -vaulted ceilings, Me Inzulatlon may be retluced to R-38 if Me full Insulation depth ends over <M1e foil place .f the eMeri.r wan. f lt uz Inzulatlon Installed over an existing slab is ol-Ild 1. be eq.-l- to the required pe dmeter abin-Rion when applied to existing slabs complying -,Section R5031.1. If foam plastic Is used, It snail meet the requirements f.rthertnal barriers protecting loam plastics. F.rlog structures developed in compliance -h Standard ICC 400. log walls shall meet the requirements far g climate zone 5 of,- 400. t. (Intermediate framing) den.t"sframing and Inzulatlon as described In Seck.n A303.2.2 Including standard h framing 16 Inch. on centet 78%of Me wall cavity insulated and headers inaul-di with aminimum of R-10 -ti Washington Slate Energy Code-Resreen[iol Prescriptive Energy Cade Campliancef.rAll Climae tones in WazM1ing[an singleFamily-New&Additians(e(fettite February 1, 2021) -1, dwelling unit I. o residential building snail comply with s-i,ie nt options from Table Rm6.2 (fuel m.ToaOoncr.ditsl and Table 406. Jenergy-lits)to achieve the fallowing minimum number of credos. To claim this -4 the bmlding permit drawingzshallspecify theopit.. seledetl and the bulking au leakage, no show the qualifying ventilation stem antl tion system its control zequens of ape amatnsted 1. Dwelling Unit' 3 Small Credits Dwelling unitsi-, than L500 sf i... nditi-floors reawith lessthan 300 sfof Hen - ration. -Addition, to existing building Mat are greater than 500 If of heated floor area bid less than 1'W0 0.. 2 Medium Dwelling-b 6 credits NI dwelling units thatarenotinclud.din %lar %3 3 Large M111irgl Unit Tnedils Dwelling units exceeding 5,000 sfof Conditioned floorarea 4. Additi-lessthan 500 squarefeN: IS credits Al lather additi.-h.11... t 1-3 ab. Before sela[ ngyour trNitzan this5ummarytable, re.iew the details in Table 406.3(Sing a Family), on page maryof al1- eatln. �m -di--ONE olnipm FUINmrlNlmtipn Oascripriom headngopdol, inw aGFr a mbpustlopnheatingminlmum NAE CA° 1 DA ❑ o Eleatic-disnceheatanly-furnxear -1 0 DHP vain zanalelntnvez6tance era non 3.4 p p s al tuner heating aneema .in uadlta-sxett p E,eY optiom Energy CNdX Optim Oes.iptiaw emagyoNionfromeE c g"ry onE Buikine Envelope ti ❑ I Effdent auiking Enveope 10 El 11 Ef -A guiking Envelope I ❑ Et%dent Building-lp ❑ Efficient Building E-pl, 2A ❑ 1.6 Ef., guiltling Envelope ❑ hl hiddiftEnvelope ❑ os ❑ 2.3 ,, e n raand-n-illilation o5 ❑ At Leakage Cantrolind Efficient Ventilation 1 D ❑ 23 n eakage Con-- Emrient Vemilation At -age Control and EFdent yendkti0n ❑ ❑24 ❑ 3.1' High Efficienry HVAC to ❑ Hign E%iciency HVAG 1a ❑ Ha Emciervy HVAG 1.5 ❑ 3FHigh E--y HVAC 15 O High C 13 ❑ 3� M1 HVAC C ❑ 2A ❑ gh Ill HVAC DIunbutlon system o5 ❑ 4J High Efficienry HVAC Dmtrib-system ❑ ].q ❑ 2018 Washington soot, Energy coda-easidanoial Prescriptive Energy Code Compliance for All Climate Zones in Washington Srngle Family- New & Adtlkians (-I. February 1, 2021) Summary of Table 0.4oa.x Imnt) Options EnergyCretllt Option Descriptions lmnt.) nergy optiontfromE il... antes a hcarega Efficient water Heating ee0El.5 ❑ i� sat ❑ �-f 5.3 Elfdmt Water Heating ❑ r-� 5A ENlatil Wall He ling ❑ 5.5 Fmcient Wmer Heating ❑ 5.6 E%id- water Hearing 2.5❑ 0 wable El-ric Energy (3nedhsmax) I-D Q 71 Appliance Patkage NIhN%r ! naltZn.ihiheadng satire sitetlatamazTmum of0.5W/sf lequivalen[) of heated floorareaor 500 w, whicM1ev bigger ay bet talletl the dwelling-1. b Equipmentlhtedin Table C403.3.1(4) or C403.3.2(5) o.hini tit listed in Table C403.3-x(1pr C4o3.3.2(2) d. T eMan.neoption Gam anyutegory EXCEPTIn category5. 00tion 5.l may be c.mbi,sM a. WIIh.Atkns 5.2:ll mgh 5.6. Se e Table-3. . h,It plinh,,R40hofeleddral generulonpravitletlannually,upM 3cretlltsmaz seethe comp to Table R406.2 for allrequiremBrits antl option descriptions. -Pleaseprintonly pages 1 th roughg3t of thistworksheet for submiss ion to your buildi ng official rvewiuw Pun -smile Family .1-1­-­- L4 0 1 r EXISTING DECK BELOW .../ AIIN r�TmI 1P"TI I Al 1 1 1 1 1 1 1 1 I I � 1 r , ' 1 r , 1 1 � 1 , 1 1 , ' 1 , I , I � I ' , ="--------------------------- PLAN NOTES 1. REFER TO GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. NEW 2x4 CEILING JOISTS AT 16"oc 0 (1) L iw 0 Q i �♦ w = J � z � X I w � LULu I EXISTING I w ■ 2x4 KING POST, TYP I w = PROVIDE (4)10d DETAIL-02 z TOENAILS TO TOP ■ N (2) OF NEW HEADER I I o O X ■ x _ NEW(2)2x12 z I z (1) ----------- - - - - -- - - - - -- --- - - -` -I4v------------= (2) ! I (2) r I I r I ■ II ■ EXISTING FRAMING AND WALLS w/ NO STRUCTURAL CHANGES as' ROOF FRAMING PLAN EXISTING TIED -RAFTERS, TYP --- ---------- 18' , , 1 , , 1 DETAIL-01 ; , , , , , , , LEGEND 1 , I N EXISTING 2x CEILING JOISTS, TYP EXISTING EXTERIOR WALL OUTLINE EXISTING ROOF LINES AND EAVE - — - — - — • EXISTING HEADER/BEAM BELOW FRAMING - TYP - — - — - — NEW HEADER/BEAM BELOW FRAMING - TYP (X) NUMBER OF BUILT UP STUDS IN WALL FRAMING 15' EXISTING FOOTING, 12" WIDE MINIMUM, CONTRACTOR TO VERIFY NEW POST ABOVE, TYP EXISTING (2)2x10 BEAMS EXISTING 2X10 FLOOR JOISTS, TYP 15' MAIN FLOOR FRAMING PLAN ROOF AND MAIN FLOOR FOOTNOTES FRAMING PLANS O NO TOP PLATES ABOVE HEADER 2O POCKET HEADER IN TOP OF WALL AND BEAR ON EXISTING 2x POST WALLS SHOWN SOLID �(Daz �rrannz�� v!Q~W J��z Q��z C/)w 122 S JACKSON ST - SUITE 210 SEATTLE, WA 98104 - 206.789.6038 J Q Lu 0 w � OQ 0 = Z O WC� m oo Lo O� O Lu BLD2021-0959 RECEIVED Oct 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C.7S� `JP of Was �� 0 111 _ z 43968 pp ONALE` PROJECT NO 5416-2021-01-01 PROJECT MANAGER SKH DRAWN ASM ENGINEER SCOTT HUFFORD 206.682.7049 SCOTTH @MA LSAM-TSANG.COM REV DESCRIPTION DATE PERMIT CORRECTIONS 9.28.21 FRAMING PLANS DETAIL SKETCH DETAIL - SEE THE STRUCTURAL PACKET S2*00 SCALE - NOT TO SCALE