APPROVED BLD PLN BLD2021-1143+Mechanical_Plan+8.18.2021_9.41.16_AM+2362759GENERAL INFORMATION
PROPERTY TAX NO.:
2729026
LEGAL DESCRIPTION:
581 EATING PLACES (RESTAURANTS)
PROJECT LOCATION:
10200 EDMONDS WAY
EDMONDS WA 98020
PROJECT DESCRIPTION:
LIKE FOR LIKE ROOFTOP UNIT REPLACEMENT FOR THE TWD
EXISTING UNITS -UNITS ARE BEING REPLACED WITH THE
NEWER MODEL OF THE SAME UNITS,
HVAC CONTRACTOR:
EMERALD AIRE INC
5108 D STREET
AUBURN, WA 98001
PROJECT MANAGER:
CONTACT. EMERALD AIRE, INC,
VO I CEO C 253) 872-5665
FAX. C 253) 872-5797
GENERAL CONTRACTOR:
WILCOX CONSTRUCTION
234 5TH AVE S,
EDMONDS,WA 98020
CONTACTI JOSH CARTER
VO I CEO C 425) 774 - 4185
INDEX:
PA��IACC
GENERAL MECHANICAL:
STANDARDSI
EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE
PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA,
ASHRAE, MFPA, OTHER APPLICABLE AGENCIES AND AHJ AS
APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY
CODESI
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH
ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES AND
ORDINANCES IN CASE OF CONFLICT BETWEEN THE
DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES,
THE MOST STRICT STANDARD CIN THE OPINION OF THE
ENGINEER) SHALL APPLY, THE MECHANICAL CONTRACTOR SHAL
SATISFY CODE REQUIREMENTS &REQUIREMENTS OF THE
CONTRACT DOCUMENTS AS A MINIMUM STANDARD,
APPLICABLE CODESI
2018 IMC W/WASHINGTON STATE AMENDMENTS,
2018 IBC W/WASHINGTON STATE AMENDMENTS 2017 NATIONAL
2018 WASHINGTON STATE ENERGY CODE
GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND/OR
COMBINATION FIRE/SMOKE DAMPERS,
APPROVED
VICINITY MAP:
�� 1/ ���Shell
226t h St S W
Q
Edmonds Westgate
Veterinary Hospltai PS
9 �a3
0
Rosewood Caurle was
a
1
t^`�
y Sunrise of Edmonds 9
i7
� 4'::
�a
o^
G�
c School
232nd FI SIN
NOT TO SCALE
EDMOI�DS
a
r
0
�h i sup sry sw �
�a N �
a � 225ih A� 2ffi{h FI 3VJ
s�
Edmonds Memarial�
Cemetery
s
n r-x�u, ri sw z
t102i70 Edmonds Way, The Needlepvinter
Ed m and s, WA 98� 2U � Needte�Porh stop
22811.
RFC �
�
iakeoul•delluery
� PCCCvmmunity
STar6ucks�
Markets -Edmonds
--. Takeout • t)ellvery
McDvnald's �, ..
�ehvery
Takeout • DellverY
�\
STa rhOC kS
iaheoui • [3ellvery
Q`'�\� �
�'-
�
Jaiiya Cefe: A--
Takeout • tJelivr. ry
_
_ 1�.. - �� -
OnvAulhehtfc
01� Gul�
� �Pi=
Hawaiian Poke
KeyBank Bunatinf �"�
rah :�ul
Takeaul•Oellvery
L�1HerFy's Burger
Nd
Takenul•helmr-ry
b � Madigan Securrey
f Consulting
The Trlke Stop -Child
Care and Preschool �
WSEC &COMMISSIONING NOTES:
THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND
COOLING PER WSEC 403, 2, 4, 1, 1
ECONOMIZERS SHALL MODULATE OUTSIDE AIR FROM MINIMUM TO 100%
ECONOMIZER CONTROLS SHALL BE CAPABLE OF EVALUATING OUTDOOR AIR COOLING
CAPACITY PER WSEC C403, 3, 1, 1
INSULATE REFRIGERANT PIPING PER WSEC TABLE C403r2,8
SEAL DUCTWORK PER WSEC C403, 2, 7, 3
INSULATE DUCTWORK PER WSEC C403, 2, 7, 1 AND C403, 2, 7, 2
COMMISSIONING PER WSEC C408 INCLUDING COMMISSIONING PLAN, SYSTEMS
BALANCING, FUNCTIONAL TESTING, CONTROLS TESTING, OPERATION AND
MAINTENANCE MANUALS, AND RECORD DRAWINGS, SHALL BE SUBMITTED TD OWNER
ON PROJECT COMPLETION.
INSTALL ALL THERMOSTATS AT 48" AFF
GAS FIRED ROOFTOP
UNIT
HEATING
COOLING
ELECTRICAL
INPUT
OUTPUT
SEER
#
MANUF
MODEL
LOCATION
SERVES
CFM
WC)
LWA
NOTES
(;
AFUE
TONS
V/PH
MCA
MOCP
(gS)
(MBH)
(MBH)
(EER)
RTU-1
TRANE
YSC060
ROOFTOP
KITCHEN
2000
0.5
100
80
0.8
5
14
208/3
28
40
522
82
ALL
RTU-2
TRANE
YSC090
ROOFTOP
KITCHEN
3000
0.5
150
120
0.8
7.5
13.4
208/3
43
50
847
82
ALL
NOTES:
1. W/ HONEYWELL VISIONPRO TSTAT
2. UNIT MOUNTED ON EXISTING SLEEPERS, LIKE FOR LIKE REPLACEMENT -BOTH THE EXISTING UNIT
AND THE REPLACEMENT HAVE IDENTICAL PHYSICAL CHARACTERISTICS,
I.E. SAME WEIGHTS, DIMENSIONS, ETC.
3. RECONNECT TO EXISTING GAS CONNECTION
4. PROVIDE WITH FACTORY INSTALLED RETURN DUCT SMOKE DETECTOR PER 2018 WSMC 606.2.1.
5. BOTH UNITS TO BE PROVIDED WITH MICROMETL ECONOMIZERS TO COMPLY WITH 2O18 WSMC C503.4.3 ALTERATIONS OR REPLACEMENT OF EXISTING COOLING SYSTEMS
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED BY PLANNING
Sep 02 2021
Contractor to provide Washington State licensed t
Engineer designed curb attachment in accordance with
ASCE 7-10 for units in excess of 400 pounds.
I t
I t
i
I t
� '
City Of Edmonds
Building Department
Work MECANICAL-ROOF TOP UNITS
Address 10200 EDMONDS WAY
Owner PAGLIACCI
Approved Date ; 09/02/2021
Building Official Eri,G C%a�fer
Permit Number
BLD2021-1143
HVAC LEGEND &ABBREVIATIONS:
N CK SI E N cFMI E GRD IDENTIFIER
CFM n
U SIDE WALL GRILL
® SUPPLY GRILLE
® THERMAFUSER
® RETURN AIR GRILLE
0 EXHAUST GRILLE
® EXHAUST FAN
AHU-1 EQUIPMENT TAG
O T—STAY
�As CD/NO 2 SENSOR
occ OCCUPANCY SENSOR
--= L/V WIRE
® DUCT RUN
(— � ELBOW
� ® REDUCER
� � SIDE TAPS
90 ELBOW
����� W/ TURNING VANES
nni�o`` imn��`` FLEXIBLE DUCT
� >� MANUAL DAMPER
FD♦ FD FIRE DAMPER
SD sD SMOKE DAMPER
SFD
SFD
SMOKE/FIRE DAMPER
MOTORIZED DAMPER
DD
BACKDRAFT DAMPER
VT VT
VARIABLE VOLUME/TEMPERATURE
HP
HEAT PUMP
HP
HORSEPOWER
HTG
HEATING
HTR
HEATER
ID
INSIDE DIAMETER
IN
INCHES
KW
KILOWATT
LAT
LEAVING AIR TEMPERATURE
LBS.
POUNDS
LWT
LEAVING WATER TEMPERATURE
MA
MIXED AIR
MAX
MAXIMUM
MBH
THOUSAND BTU'S PER HOUR
MIN
MINIMUM
MS
MOTOR STARTER
NC
NOISE CRITERIA
NTS
NOT TO SCALE
OA
OUTSIDE AIR
OBD
OPPOSED BLADE DAMPER
OC
ON CENTER
OD
OUTSIDE DIAMETER
PH
PHASE
PSI
POUNDS PER SQUARE INCH
QTY
QUANTITY
R/A
RETURN AIR
REF
REFRIGERANT
RET
RETURN
RH
RELATIVE HUMIDITY
RLD
RELIEF DAMPER
RPM
REVOLUTIONS PER MINUTE
S/A
SUPPLY AIR
SEER
SEASONAL ENERGY EFFICIENCY RATING
SH
SENSIBLE HEAT
SOV
SHUT OFF VALVE
SP
STATIC PRESSURE
TEMP
TEMPERATURE
UC
UNDERCUT DOOR
V
VOLT
VAV
VARIABLE AIR VOLUME
VD
VOLUME DAMPER (HAND OPERATOR)
VEL
VELOCITY
W
WATT
W/
WITH
WB
WET BULB
W/0
WITHOUT
RECEIVED
Aug 18 2021
CITY OF EDMONDS PROJECT
DEVELOPMENT SERVICES NORTH
DEPARTMENT
BUST//� SEATTLE DPD STAMP
�O of was y'9-o
Z
O
H
U
fY
H
(n
Z
O
U
tY
O
H
O
Z
N
tl
Y
fY
Q
c�
z
x
W
L�
0
Z
0
J
0
U
fr
0
w
>_w
Lu1
Z
O
H
U
N
W
N
z
fi
w
Q
0
z PLOT DATE 8/16/2021
w
w
m
O
z
(n
Q
z
Q
0
H
DESIGN DEVELOPMENT
❑
DRAWING
DATE
--
❑
COORDINATION
DATE
®
PERMIT
DATE
❑
CONSTRUCTION
DATE
❑
AS BUILT
DATE
0
z
0
�O
0
�
W
�
o�
z Q
�
�
� (/•)
wo
U
oz
0
U
oQ
Q
� w
J
Q
m
w
Z
z
�
wQ
�
U
�
� J
In � m
o����
���NlnO
ZOt �^NQ
I �
0
c~n3�o�o.-.w
0 �`-'r7�
tnm�� X�
�
Q J Lam �
Q
o
a
�
fJ
�
w
;,
(�
o
�i
o
�
�
�
c
Q
�
�
U
s;
N
p�
Q)
r7r rnr rnt
IJ
U
w
HVAC COVER SHEET
SCALE: AS —NOTED
�� 8' �'�' ��GrsTE��� ���
I � ��SIONAL E���
0' 4' 16'
SCALE: 1 /8" = 1'-0" 8 / 16 / 2 0 21
P:\Working Projects\Pagliacci— Edmonds (221-0803)\Engineering\CAD Drawings\Pagliacci — Edmonds\Sheets\M0.0 HVAC COVER SHEET.dwg
M0.0
221—XXXX
��.
QO��.,/ xti
,`J� c�P
�,
C/�
W
W
U
Q
-�— —
O
/� — _ _---
�� __ �\
r
\ �
1 \ \
�P ��\ �
�� .
�_
RECEIVED ��
Aug 18 2021 a D
CITY OF EDMONDS PROJECT
DEVELOPMENT SERVICES NORTH
DEPARTMENT
BUST/N SEATTLE DPD STAMP
�O of was y9�
z
0
U
D_
N
z
0
U
O
f-
O
Z
N
0_
Y
Q
C.�
Z
H
�_
X
W
L�
O
Z
O_
J
0_
O
U
O
0
w
_w
Z
O
D_
U
N
W
(/)
Z
O
_>N
W
w
Q
0
z
PLOT DATE 8/16/2021
w
w
m
f-
O
Z
Q
2
C�
z
Q
0
�_
H
DESIGN DEVELOPMENT
❑
DRAWING
DATE
--
COORDINATION
DATE
®
PERMIT
DATE
CONSTRUCTION
DATE
AS BUILT
DATE
0
z
0
O
o
w
��
0
��
o �;
Wo
U
oz
o�
U
No
Q
�w
J
C�
Q
m
w
z
z
�
J
�
W
J
Q
�
�
U
�
rn
J
ll') I� m
O � � n ll')
3��pNl[')O
ZOO �^NQ
n
N3CV O��
I� pp �-. W
pZ�vN)�
i-. � W
O_O � Wv�
� m � � X � �'
J lam � Q
o Q
� W
� o
.y o �
� Q �
a
x g
w �
HVAC SITE PLAN
I SCALE: AS —NOTED
HVAC SITE PLAN
�� SCALE: 1 /8" = 1' 0"
2' 8'
��GISTE���
SIGN
0' 4' 16'
SCALE: 1 /8" _ ,'-o" 8 / 16 / 2 0 21
P:\Working Projects\Pagliacci— Edmonds (221-0803)\Engineering\CAD Drawings\Pagliacci — Edmonds\Sheets\M1.0 HVAC SITE PLAN.dwg
M 1.0
221-XXXX
B.6
�EVE� 1 HVAC P BAN
�� SCALE: 1 /4" = 1' 0"
— — — — — —
I
(�, ,��
r'
,d �' I I I
I
I
I
III-----------------
. — _�==—�--=
II� II
----------------------
N� cHAN���
SYSTE
/� � II I
' I WOMEN C1
� � 112 I
HALL I
NEW THERMOSTATS TO BE PROVI Q, LO T IN / 110 11
THE SAME LOCATIONS AS EXISTI �f �'J
A
D
FRONT LINE
102
��� I
�\
� os
r��
C1 A � I \
107
COOLER
109
I I
-- --- ------------
II II
II - II -
To ExisTiN�
=MS ON
o
THIS
-- �
O�� �� II
O II
J
I I III
II
II
DISPLAY KITCHEN
104 II
�Lo�
,���
oar oars oar
I I KITCHEN &STORAGE
II 108
A
� � � a
lul
i❑
HVAC
LEVEL
- � 103
� I
� I
I \ � JSERVICE
105
�''
r
___J
era
UTILITY I I
104 STAFF
107
a
16
I 105
OFFICE
113
n A
2 1.8
A
RECEIVED ��
Aug 18 2021 a D
CITY OF EDMONDS PROJECT
DEVELOPMENT SERVICES NORTH
DEPARTMENT
SEATTLE DPD STAMP
/ ti�
��
Z
O
H
U
H
f/)
Z
O
U
Q'
O
H
O
Z
(/')
D_
Y
Q
U
Z
N
X
W
0
z
0
J
D_
O
U
0
0
w
w
Z
O
D_
U
N
W
N
Z
O
N
w
a
0
w
z
PLOT DATE 8/16/2021
w
w
m
H
O
Z
Q
C�
z
Q
N
1 � 4' �� ��' ��GtsTER�� �'�
I � ��SI�NAL ����
o' 2' s'
SCALE 1 /4" _ ,'-o" 8 / 16 / 2 0 21
P:\Working Projects\Pagliacci— Edmonds (221-0803)\Engineering\CAD Drawings\Pagliacci — Edmonds\Sheets\M2.0 LEVEL 1 HVAC PLAN.dwg
DESIGN DEVELOPMENT
DRAWING
DATE
--
❑
COORDINATION
DATE
®
PERMIT
DATE
CONSTRUCTION
DATE
❑
AS BUILT
DATE
(�
z
�
Qo
�
�o
LJJ
(/') �
��
o�
wo
U
oz
0
U
oQ
Q
� w
Q
m
z
z
�
w
J
Q
�
�
U
�
� J
��m
o�'��
� � c0 N ll') O
ZOO �^NQ
N3cV O��
I� W
pp ^
pZ ��N")�
O� � W��
Q J � OU
Q
o
Q
�
W
=�
c�
o
.�
o
a
o
U
Q
_
�
(p
,nn-nnonn
N
L�
U
W
LEVEL 1 HVAC PLAN
SCALE: AS —NOTED
M2.0
221—XXXX
STOP GU T-
SHORT OF
B
BUILDING STEPS UP CONCEAL EQUIPMENT
FROM ROAD, PARAPET HEIGHT AROUND EAST,
WEST, AND SOUTH CONCEAL EQUIPMENT
LIKE FOR LIKE UNIT REPLACEMENT -
HAVE IDENTICAL PHYSICAL PROPERTIES
DIMENSIONS, ETC. MOUNT UNIT TO EXISTI
AND CONNECT TO EXISTING DUCTWORK;
INTAKES AS NEEDED TO MAINTAIN 10'
ANY EXH,
B.6
PER 2018 WSMC 304.11 GUARDS, NO GUAF
REQUIRED, PARAPET HEIGHT MEETS OR EXCEE
42" ABOVE ROOF DE
R00� HVAC PLAN
CONCEALED
6"x4" GUTTER
4"x2"
DOWNSPOUT
J SCHEMATICALLY IN GRAY
CEMENT — BOTH
SICAL PROPERTIES.
=TC. MOUNT UNIT TO
ONNECT TO EXISTING
ITAKES AS NEEDED TO
0 ANY EXHAUST
i i i
i i i i
5 4.9 4 3 2 1.8 1
RECEIVED ��
Aug 18 2021 a D
CITY OF EDMONDS PROJECT
DEVELOPMENT SERVICES NORTH
DEPARTMENT
SEATTLE DPD STAMP
�� $� � �°��s ���sTERti ���w
I � SIDNaL E�
0' 4' 16'
SCALE: , /8" _ ,'-o" 8 / 16 / 2 0 21
P:\Working Projects\Pagliacci— Edmonds (221-0803)\Engineering\CAD Drawings\Pagliacci — Edmonds\Sheets\M2.1
Z
O
H
U
H
(/')
Z
O
U
O
L�
H
O
Z
N
0_
Y
Q
C.�
Z
H
�_
X
W
l.�
O
Z
O_
J
0_
0
U
O
L�
w
w
z
w
w
m
O
Z
C�
z
Q
N_
2
H
Z
O
U
N
W
0
(n
Z
0
>�_
L�1
w
Q
0
PLOT DATE 8/16/2021
DESIGN DEVELOPMENT
❑
DRAWING
DATE
--
COORDINATION
DATE
®
PERMIT
DATE
❑
CONSTRUCTION
DATE
AS BUILT
DATE
0
z
0
�
�o
o
w
��
�
�
� (/')
wo
U
oz
O
U
oQ
Q
�w
Q
m
L.LJ
Z
Z
�
J
�
Lv
J
Q
�
�
U
�
� J
l/') I� m
o I I� 11")
�
��tDN�O
ZOO �^�yQ
I � Q
c~i� 3 � �
.-.w
� W
�� � wv�k
ln�vL�i jXH
Q J � O
�
Q
Q
E�J
W
�,
�
o
��
o
a
�
o
U
C
p�'
U
w
g
_
�
ROOF HVAC PLAN
SCALE: AS —NOTED
�� SCALE: 1 /4" = 1' 0"
ROOF HVAC PLAN.dwg
M2.1
221—XXXX