REVIEWED BLD RESUB1 BLD2021-1190+Interior_Lighting_Summary+9.28.2021_10.33.25_AM+24323092018e Energy Code Compliance Forms for Commercial Buildinqs including R2, R3, R4 over 3 stories and all R1 Revised Auq 2021 rev. 3 Project Info Project Title: LifeStance Health Date 9/24/2021 Compliance forms do not Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For SDCI L se g LD2021-1190 require a password to R E j u Company Name: BlueStreak Consulting Company Address: 25001 Emery Road, Suite 410 use. Instructional and calculating cells are write- protected. Sep 28 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Applicant Name: Cassie George Applicant Phone: 216-233-3286 Applicant Email: cgeorge@bluestreak-consulting.com Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting System All fixtures are LED type. Automatic time -clock within the nLight system controls Description the automatic off capabilities of Corridor, Waiting and Reception. All other spaces that require automatic off controls are provided with wall mounted, occupancy sensor wall switches. Rooms that are exempt to have automatic controls per Washington Energy Code are provided with a low voltage on/off switch that is ❑� Interior Lighting Plans Included programmed to turn the lights 100% on when activated. Interior Lighting Power 0 Building Area Method ❑ Space -by -space Method Allowance Method Select method used in project. Interior Lighting Controls 0 All C405.2, Item 1 Lighting Controls ❑ Control405. (Item 2 Luminaire Level Lighting ❑ Additional Efficiency Package Option C406.4 Enhanced Digital Lighting Controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Sleeping/ Dwelling Unit Area of multifamily dwelling units complying with C405.1.1 and C405.7 N/A Interior Lighting Area of all other dwelling and sleeping units complying with C405.1.1 and C405.2.5 N/A Area of all other dwelling and sleeping units complying with C405.5 and C405.2.5 N/A Exterior Lighting System Not Applicable Description ❑ Exterior Lighting Plans Included Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project ❑ ❑ Refer to Section C502.2.6 for additional requirements. Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance ❑ ❑ Addition is combined with existing: For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. 2018 Seattle Enerqv Code Compliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 Revised Auq 2021 rev. 3 Project Title: LifeStance Health Date 9/24/2021 Change of Space Use ❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations Spaces with more lighting than threshold added, altered or replaced ❑� ❑ ❑ (20% int., 20% garage, 20% ext.) Spaces with less lighting than threshold Select all Lighting Power and Lighting Control elements that apply to the scope added, altered, or replaced ❑ ❑ ❑ of the retrofit project. If project includes (20% int., 20% garage, 20% ext.) multiple spaces (rooms separated by Lamp and/or ballast replacement only — ceiling height partitions), each space existing total wattage not increased ❑ ❑ ❑ where less than 20% of the existing More lighting than threshold replaced - Total lighting power of new + existing -to -remain fixtures shall fixtures are added, altered or replaced can be combined on a single LTG-INT-SPACE comply with total LPA per Sections C405.4.2 and C405.5.3. Include new + existing -to -remain fixtures in form. Spaces where 20% or more of the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. fixtures are added, altered or replaced Less lighting than threshold replaced - Total lighting power of new + existing -to -remain fixtures shall and additions may be combined onto one not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the lighting power compliance form. Parking Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. garages and exterior lighting also have 20% thresholds. The threshold for interior lighting is 20% of the luminaires within an enclosed space, for parking garages the threshold is 20% of the luminaires within the garage, and for exterior spaces the threshold is 20% of Refer to Section C503.6 for additional the total installed lighting power for the exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added All alteration lighting controls shall be commissioned per C408.3. fixtures and/or fixtures relocated to new ❑ ❑ ❑ circuit(s) New or moved lighting panel ❑ ❑ ❑ Interior space is reconfigured - ❑ luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting No changes are being made to controls per C405.2.5. For exterior lighting, provide required controls per C405.2.6. ❑ the interior or exterior lighting New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic systems and existing space time switch controls per C405.2.2. uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. 2018 Seattle Energy Code Compliance Forms for Commercial Buildinqs including R2, R3, R4 over 3 stories and all R1 Revised Auq 2021 rev. 3 Project Title: LifeStance Health Date 9/24/2021 Calculation Q New Construction Q Addition - O Addition For SDCI Use Area NOTE $ stand alone + existing O Spaces where < 20% of O Spaces where z 20% of O Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) LPA Q Standard O C406.3.1 Reduced LPA 10% C406.3.2 Reduced LPA 20% Calculation User Note Type To comply with C406.3.1 or C406.3.2 the Proposed LPD shall be 10% or 20% lower respectively than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE I Watts Allowed Location (plan #, Gross Interior Allowed (watts/ft2 x area) Building Area room #, or ALL) Area Description Area in ftZ Watts per ftZ NOTE 2 Office E2.0 Entire Space 3658 0.58 2,122 Total Proposed Lighting Wattage Building Area Location (plan #, room #) Fixture Description NOTE 3, 4, 5, 6 Number of Fixtures Watts per Fixture NOTE 7 Watts Proposed Office E1.0, E2.0 A (6"x4' Linear LED Fixture) 24 40 960 Office E1.0, E2.0 Al (6"x4' Linear LED Fixture) 30 24 720 Office E1.0, E2.0 61 (2'x4' Recessed LED Fixture) 1 37 37 Office E1.0, E2.0 C (6" LED Downlight Fixture) 6 10 60 Office E1.0, E2.0 D (4' LED Strip Fixture) 1 34 34 Office E1.0, E2.0 P1 (14" Decorative LED Pendant Fixture) 12 9 108 Office E1.0, E2.0 P2 (8" Decorative LED Pendant Fixture) 3 9 27 Office E1.0, E2.0 S1 (12" Decorative LED Sconce Fixture) 12 5 60 Office JE1.0, E2.0 S2 (5" Decorative LED Sconce Fixture) 1 13 1 7 191 Office JE1.0, E2.0 IS3 (14" Decorative LED Sconce Fixture) 1 2 1 9 118 Compliance by Building Area""' Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Office Exceeds maximum allowed wattage for this building area for C406.3 compliance 2122 2115 COMPLIES Totalsi 2,122 12 ,115 Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the project scope. Select building area category fro m drop down menu. Note 2 - When Watts Allowed indicates "Unlit" no proposed lighting has been entered. Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 3 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures includin g exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast informati on. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other appro ved source. For luminaires with screw -in lamps, enter the input wattage of the installed lamp. For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 16 wattsdineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Building Area types and gross interior areas. c. If less than 20% of existing lighting fixtures will be replaced, use L TG -INT-SPA CE form to document compliance. PermitLighting, Motor, and Electrical • 2018 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Aug 2021 rev. 3 Project Title: LifeStance Health Date 9/24/2021 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in (yes,no,na) Code Section Component Compliance information required in permit documents Documents SDCI Notes LIGHTING CONTROLS C405.2 Lighting controls, For all lighting systems, indicate lighting control method on Yes general plans for spaces and lighting zone(s) served, or exception taken E2.0 C405.2 LLLC required for For open office areas larger than 5000 sf, provide LLLC fixtures NA open office or enhanced digital lighting control system C405.2, Luminaire level Indicate on plans all fixtures provided with LLLC complying with NA Option 2 lighting controls C405.2 option 2 lighting controls; provide description of control (LLLC) capabilities and performance parameters C405.2.5 Lighting in dwelling Indicate method of automatic control of all installed luminaires in Item 3 units (dormitory, hotel dwelling units in buildings other than multifamily (occupancy or NA C405.2.1.1 and all other than light reduction controls) C405.2.3.1 multifamily) C405.2.5 Lighting in sleeping Indicate method of automatic off control of all installed NA Item 2 units luminaires in sleeping units (vacancy or key card control); also refer to Receptacles C405.2.3 Manual controls Indicate on plans the method of manual lighting control, location Yes C405.2.3.1 of manual control device and the area or specific application it E2.0 C405.2.5 serves C405.2.1.1 Manual interior light Indicate on plans which method of manual 50% lighting load Yes C405.2.3.1 reduction controls reduction is provided, or indicate applicable exception E2.0/E1.2 C405.2.4 C405.2.1 Method of automatic Indicate on plans the method of automatic shut-off control C405.2.2.1 shut-off control during unoccupied periods (occupancy sensor, time switch or Yes C405.2.1, digital timer switch) for all lighting zones; E2.0/E1.2 Exception 3 Indicate on plans all luminaires that are controlled by occupant sensor controls; indicate controls are configured to turn E2.0 luminaires 100% off when the space is unoccupied; Indicate if occupant sensor controls are configured to be C405.2.1 Occupancy sensor manual on or automatic on to not more than 50% power; Occupancy Yes C405.2.1.1 controls indicate spaces eligible for exception that allows automatic on sensors shall be to 100% power programmed as Automatic on/ Automatic off and lights to "Full On" C405.2.1.2 Occupant sensor Indicate each aisleway and corridor within a warehouse space NA controls - are designated as separate zones that are independently warehouses spaces controlled C405.2.1.2 Occupant sensor Indicate occupant sensors are configured to automatically controls - warehouse reduce lighting power by 50% within 20 minutes of all occupants spaces, storage leaving the zone; indicate controls are configured to NA areas and service automatically restore full power when the zone is occupied; corridors indicate occupant sensors turn lighting off within 20 minutes of all occupants leaving the space, or time switch controls provided C405.2.1.3 Occupant sensor For open plan office areas larger than 300 sf, indicate general controls - open plan lighting is provided with vacancy controls that reduce lighting NA office areas power by not less than 80% and are configured to turn luminaires 100% off when the open plan office area is unoccupied; indicate that no individual control zone area C405.2.1.4 Occupant sensor Indicate parking garage general lighting is provided with controls - parking vacancy controls to automatically reduce lighting power by not garages less than 30% within 20 minutes of no activity being detected; NA indicate that no control zone exceeds 3,600 sf; indicate occupancy sensors turn lighting off within 20 minutes of space vacancy, or time switch controls provided C405.2.1.5 Occupant sensor Indicate stairway lighting is provided with vacancy controls that NA controls - enclosed reduce lighting power by not less than 50% when the stairway in fire -rated stairwells unoccupied Indicate spaces on plans where time switch controls turn luminaires 100% off during unoccupied hours E2.0/E1.2 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which E2.0/E1.2 Automatic time time switch control exception applies Yes C405.2.2.1 switch controls Indicate spaces on plans where time switch controls are configured to turn on lighting to full power versus 50% power E2.0/E1.2 Indicate locations of override switches on plans and the lighting zone(s) served; indicate that the area(s) served by each E2.0/E1.2 override switch does not exceeds 5,000 sf C405.2.1, Digital timer switch Indicate digital timer switch control includes: manual on/off, time Yes Exception 3 delay, audible and visual indication of impending time-out E2.1 Indicate primary and secondary sidelit daylight zone floor areas E2.0 on plans; Indicate toplit daylight zone floor areas on plans; NA C405.2.4.2 Daylight zones - For small vertical fenestration assemblies (rough opening less ( 9 P 9 Yes C405.2.4.3 Sidelit and toplit than 10 percent of primary daylight zone floor area) where NA daylight responsive controls are not required, provide fenestration area to daylight zone floor area calculation(s) PermitLighting, Motor, and Electrical • 2018 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Aug 2021 rev. 3 Project Title: LifeStance Health Date 9/24/2021 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in (yes,no,na) Code Section Component Compliance information required in permit documents Documents #REF! Indicate on plans lighting zone(s) served by daylight responsive controls; indicate that the area served by each control device does not exceeds 2,500 sf; Identify sidelit and toplit daylight zones that are not provided NA C405.2.4 Daylight responsive with daylight sensing controls and the exception(s) that apply; controls Indicate on plans the lighting load reduction method (continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power); Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone Additional controls - Identify spaces and lighting fixtures on plans that require NA C405.2.5 Specific application specific application lighting controls per this section lighting controls Indicate on plans that manual controls are provided that control display, accent lighting and display case lighting independently NA C405.2.5 - Display and accent from both general area lighting and other lighting applications Item 1 lighting within the same space; Indicate manual and automatic (occupant sensor or time switch) lighting control methods C405.2.5 - Hotel/motel guest Indicate method of automatic control - vacancy or captive key NA Item 2 control of all installed luminaires and switched receptacles in rooms guest room C405.2.5 - Supplemental task Indicate method and location of manual and automatic shut-off NA Item 1 lighting control (occupant sensor or time switch) for supplemental task lighting, including under -shelf or under -cabinet lighting Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general NA C405.2.5 - Supplemental task area lighting and other lighting applications within the same Item 1 lighting space; Indicate manual and automatic (occupant sensor or time switch) lighting control methods Identify all eligible non -visual lighting applications on plans; indicate that the area served by each control device does not exceeds 4,000 sf; NA C405.2.5 - Lighting for non- Indicate on plans that non -visual lighting are controlled Item 4 visual applications independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Identify on plans egress fixtures that function as both normal E2.0 and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting operating 24/7 and demonstrate that is is equal to or less than 0.01 W/ft2; BG1/SC1 Yes C405.2.5 - Means of egress Item 5 lighting Automatic time Indicate method of automatic shut-off control switch or occupant sensing within room For decorative exterior lighting, indicate on plans automatic daylight shut-off controls, or exception taken For exterior lighting that is not decorative, indicate on plans Exterior lighting automatic daylight or time -switch shut-off controls and setback NA C405.2.6 controls controls; or indicate exception taken For lighting requiring setback controls, include control sequence that reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor Exterior lighting For building facade and landscape lighting, indicate control NA C405.2.6 controls - Building sequence for shut-off control is based on dawn -to -dusk and facade and business opening/closing schedule; indicate whether automatic landscape or time switch controls will be provided for this function NA C405.5.4 Exterior gas -fired Indicate ignition system is a method other then continuously lighting appliances burning pilot light Area controls - Indicate location(s) of master control switch(es) intended to Master control control multiple independent switches; circuit breaker may not NA C405.2.7 switches and circuit be used as a master control switch; Verify that no single switch controls more than one 20-amp E1.0 power limit circuit, loaded to maximum 80% capacity ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS To comply with additional efficiency credit, indicate on plans that interior lighting fixtures are configured with all of the following control functions, as applicable: 1) Each fixture is individually addressed, or exception taken; 2) Fixtures are configured for continuous dimming; 3) No more than eight fixtures are controlled by a single daylight sensor; 4) In Enhanced digital enclosed and open office areas, illumination levels of overhead NA C406.4 lighting controls general area lighting is configured to be individually adjusted by occupants; Include calculations that demonstrate the total lighting power of all interior lighting fixtures configured with enhanced lighting controls is no less than 90% of the total interior lighting power for the area the enhanced lighting controls credit is being applied to PermitLighting, Motor, and Electrical • 2018 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Aug 2021 rev. 3 Project Title: LifeStance Health Date 9/24/2021 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in (yes,no,na) Code Section Component Compliance information required in permit documents Documents SDCI Notes INTERIOR LIGHTING POWER & EFFICACY Include all luminaires in interior lighting fixture schedule; E1.0 Luminalire indicate fixture types, lamps, ballasts, and manufacturer's watts Schedule per fixture for the installed lamp; Identify spaces eligible for lighting power exemption on plans C405.4.1 Total connected Yes C405.4.2 interior lighting power and in SEC interior lighting compliance reports; indicate the NA exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in SEC interior lighting compliance NA reports; indicate the exception applied; Total connected Indicate on plans any areas where proposed wattage is NA C405.4.1 interior lighting power calculated as the total dedicated lighting branch wattage; detail alternative rated wattage and proposed lighting power for each branch For all installed luminaires, include lamp type and number of NA C405.1 Lighting in dwelling lamps in lighting fixture schedule; for lamps that are not LED, T- C405.1.1 units (multifamily) 8 or small diameter fluorescent, indicate efficacy of other lamp types is 65 lumens per watt or greater Lighting in dwelling For all installed luminaires, indicate in lighting fixture schedule NA C405.1 units (dormitory, hotel whether complying via lighting power density or by qualifying gC405.1.1 and all other than lamp type; if by lamp type, include number of lamps multifamily) Lighting in sleeping For all installed luminaires, indicate in lighting fixture schedule NA JC405.1 C405.1.1 units whether complying via lighting power density or by qualifying lamp type; if by lamp type, include number of lamps Interior Lighting Power Calculation - Indicate compliance path taken Demonstrate that total proposed wattage per building area does Yes C405.4.2.1 Building Area Method not exceed maximum allowed wattage per building area; identify LTG-INT-BLD locations of building areas on plans; provide SEC exterior lighting compliance reports Demonstrate that total proposed wattage does not exceed Space -By -Space maximum allowed wattage; identify locations of space types on NA C405.4.2.2 Method plans, including retail display areas and areas with display, highlight and decorative lighting; provide SEC exterior lighting compliance reports ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY To comply with additional efficiency credit, demonstrate that total connected interior lighting wattage is 10% or 20% less than C406.3.1 Reduced interior the total maximum allowed lighting wattage for the area the NA C406.3.2 lighting power density reduced lighting power credit is being applied to; indicate whether lighting power allowance is based on the building area method or space -by -space method; provide SEC exterior lighting compliance reports For project with dwelling units, to comply with additional Reduced interior efficiency credit indicate in lighting fixture schedule that lamps NA C406.3 lighting power density within installed interior luminaires have an efficacy rating of at - dwelling unit lamp least 65 lumens per watt; include number of lamps and provide efficacy calculations that demonstrate at least 95% of lamps have this efficacy rating EXTERIOR LIGHTING POWER & EFFICACY Include all luminaires in exterior lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's watts per fixture for the installed lamp; Identify exterior applications eligible for lighting power Total connected NA C405.5.2 exterior lighting exemption on plans and in SEC exterior lighting compliance reports; indicate exception applied; power Indicate that exempt exterior lighting and lighting located within exterior areas/surfaces that eligible for a lighting power exemption are controlled independently from non-exempt exterior lighting; NA C405.5.3(1) Exterior lighting zone Indicate building exterior lighting zone as specified by the AHJ Exterior building For building grounds fixtures rated at greater than 50 watts, NA C405.5.1 grounds lighting indicate rated lamp efficacy (in lumens per watt) in fixture schedule Identify locations of tradable and non -tradeable surfaces on plans NA C405.5.3 Exterior lighting power calculations Complete required compliance form —proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed For open parking, outdoor area, and roadway luminaires NA C405.5.5 Full cutoff luminaires mounted more than 15 feet above the ground, indicate fixture with zero candela at an angle of 90 degrees. Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG-CHK 2018 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Aug 2021 rev. 3 Project Title: LifeStance Health Date 9/24/2021 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in (yes,no,na) Code Section Component Compliance information required in permit documents Documents SDCI Notes LIGHTING ALTERATIONS Where >_ 20% of existing luminaires in an interior space or parking garage are replaced; indicate compliance path (building area or space -by -space method); include all new and existing -to - remain luminaires in SEC interior lighting compliance reports; indicate proposed lighting wattage does not exceed maximum Interior and parking allowed per compliance path Where < 20% of existing luminaires in an interior space or NA C503.6.1 garage lighting fixture alterations parking garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing -to -remain luminaires in SEC interior lighting compliance reports; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration Where z 20% of existing exterior lighting wattage is replaced; include all new and existing -to -remain luminaires in SEC exterior lighting compliance reports; indicate proposed total exterior lighting wattage does not exceed maximum allowed NA C503.6.1 Exterior lighting fixture alterations o Where < 20% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in SEC interior exterior compliance reports; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate NA C503.6.2 Interior lighting wiring manual and automatic lighting controls are provided (as alterations applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); light reduction (C405.2.3); daylight responsive (C405.2.4); specific application (C405.2.5); Exterior lighting Where new wiring is installed to serve new exterior luminaires NA C503.6.2 wiring alterations and /or luminaires are relocated to a new circuit; indicate automatic lighting controls are provided (C405.2.6) Where a new interior and/or exterior lighting panel is installed or NA C503.6.3 Lighting panel an existing panel is moved (all new raceway and conductor alterations wiring), indicate all applicable lighting controls requirements apply Where interior space(s) is reconfigured (permanently installed Yes C503.6.4 Newly -created rooms walls or ceiling -height partitions) to create new enclosed E2.0 spaces, indicate all applicable lighting controls requirements apply Identify spaces on plans where the building area type or space use type is being changed from one type to another per Tables Entire Space C405.4.2(1) or (2) Indicate compliance method (building area or space -by -space); Yes C505.1 Change of interior space use include all new and existing -to -remain luminaires in SEC interior LTG-INT-BLD lighting compliance reports; indicate proposed lighting wattage does not exceed maximum allowed per compliance path Indicate lighting controls provided per C405.2 E2.0/E1.2 RECEPTACLES Identify all controlled and uncontrolled receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Provide schedule that lists the number of controlled and Controlled uncontrolled receptacles in each space where controlled NA C405.10 receptacles receptacles are required - classrooms, private offices, open office areas, conference rooms, copy rooms, break rooms and modular partitions/workstations Indicate on plans the method of automatic control for each controlled receptacle zone (occupant sensor or programmable time -of -day control); indicate that each zone served by a single controller does not exceed 5,000 sf; NA C405.2.5 Switched receptacles Indicate method of automatic off control of all switched Item 2 in sleeping units receptacles in sleeping units (vacancy or key card control) Where new receptacles are added or replaced within an NA C503.6.6 Electrical receptacle alteration project that is 5,000 sf or larger, indicate new or alerations altered receptacles are provided with automatic controls per C405.10, or exception taken PermitLighting, Motor, and Electrical • 2018 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Aug 2021 rev. 3 Project Title: LifeStance Health Date 9/24/2021 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in (yes,no,na) Code Section Component Compliance information required in permit documents Documents SDCI Notes MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION NA C405.6 Electrical Include electrical transformer schedule on electrical plans; transformers indicate transformer type, size, efficiency, or exception taken Yes C405.11 Feeders and branch Provide documentation that demonstrates maximum voltage E2.0 circuits drop across feeders and branch circuits does not exceed 5% Dwelling unit Indicate on electrical plans that each dwelling unit in Group R-2 NA C405.7 electrical energy has a separate electrical energy meter consumption NA C405.7.1 Receptacles at gas provide 240/208 volt receptacle at each gas appliance appliances Electric motor Include all motors, including fractional hp motors, in electric NA C405.8 efficiency motor schedule on electrical plans; indicate motor type, horsepower, rpm, rated efficiency, or exception applied For luminaires in each elevator cab, provide calculations that demonstrate average efficacy is not less than 35 lumens/W; Indicate rated watts per cfm for elevator cab ventilation fans do NA C405.9.1 Elevator cabs not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more Indicate escalators comply with ASME A17.1/CSA B44; NA C405.9.2 Escalators and automatic controls are configured to reduce operational speed moving walks to the minimum permitted when not in use or uses a variable voltage drive system NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx) Indicate that controlled receptacles are required to be commissioned Scope of electrical p Where total building lighting load is > 20 kW, or where total Commissioning of Lighitng System is Yes C408.4 power and lighting lighting load of luminaires requiring daylight sensing and / or exempt as total systems occupancy control > 10 kW, indicate that all automatic lighting lighting is <20kw commissioning control systems are required to be commissioned; or provide and daylight building lighting power calculation demonstrating eligibility for exception; and/or occupancy controls is <10kw E1.0 Commissioning Notes. Lighting and Lighting Indicate Cx requirements in plans and specifications for all Control Systems applicable electrical and lighting control systems per C408; are exempt from commissioning due to the total C405.13 Commissioning installed lighitng C408.1.1 requirements in load is less than Yes C408.1.2 construction 20kw C408.1.4 C103.6 documents Include general summary of Cx plan per C408.1.2 including: 1) Narrative description of activities; 2) Responsibilities of the Cx E1.0 team; 3) Schedule of activities including verification of project Commissioning close out documentation per C103.6; 4) Conflict of interest plan Notes (if required); Include in general summary that a Cx project report and E1.0 Compliance Checklist (Figure C408.1.4.1) shall be completed Commissioning by the Certified Cx Professional and provided to the owner prior to the final electrical inspection Notes Functional Identify in plans and specifications the intended operation of all E1.0 Yes C408.4.1 performance testing equipment and controls during all modes of operation, including Commissioning criteria interfacing between new and existing -to -remain systems Notes PROJECT CLOSE OUT DOCUMENTATION Indicate in plans that project close out documentation is Project close out required including SEC lighting compliance forms and E1.0 Yes C103.6.3 documentation calculations that document all interior and exterior lighting area Commissioning requirements and / or surface types, lighting power allowances and installed Notes densities If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist