Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2021-0122+Fire_Alarm_Equipment_Specification_Sheets+11.4.2021_12.56.26_PM+2502902
RECEIVED 11/4/21 r Fire Systems West, Inc ■ CITY OF EDMONDS DEVELOPMENT 206 FRONTAGE ROAD NORTH, SUITE C SERVICES DEPARTMENT PACIFIC, WA 98047 (253) 833-1248 J I :i :9_101_1:i u Equipment Submittal FOR LifeStance 21727 76t" Ave W, Suite-C Edmonds, WA 98026 '-DS6 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Silent Knight and is a direct replacement for the 5495/5499. The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp, remote power supply with battery charger that maybe connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently -configurable, power - limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non- resettable 24V auxiliary power —door holder power • Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power -supervision relay (EOLR-1) • Configurable for ANSI° Temporal 3 or Temporal coded output • UL-Listed NAC synchronization using System Sensor®, Wheelock', Gentex°, or AMSECO° appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) orthree (10 amp model) fully -isolated input/control circuits which can be programmed to any output • Two Form C normally -closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end -of -line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a 0 A corrosion -resistant powder coat chip and scratch -resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry -standard reverse -polarity notification circuit Honeywell SILENT' KNIGHT ORDERING INFORMATION SK-PS6: 6.0 A,120 VAC remote charger power supply in a lockable, metal enclosure, red SK-PS10:10.0 A,120 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A converter card, sold separately SK-CONTROL: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external24 VDC to power notification appliances. SK-RELAY: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch SK-MONITOR: Addressable Monitor Module for one zone of normally open dry -contact initiating devices. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Class B or Class A SK-MONITOR-2: Dual Monitor Module. Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only SK-CONTROL-6: Six -circuit supervised control module SK-RELAY-6: Six Form-C relay control module EOLR-1:12/24 VDC end -of -line relay for monitoring four -wire smoke detector power BAT-1270-BP: Battery,12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery,12 volt,18AH, 2-pack BAT-12330: Battery,12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. Page 2 of 3 — SK-61095:C • 3/10/2021 SK-PS6 / SK-PS10 TECHNICAL SPECIFICATIONS PRIMARY (AC) POWER SK-PS6:120 VAC, 50/60 Hz, 5.OA maximum SK-PS10:120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input:1.0 mA (9 -16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • SK-PS6: T138-TI39 — lA Regulated, 3A special applications; TB10-TB12 — 0.3A Regulated, 3A special applications • SK-PS10: T138-TB11-1.5A Regulated, 3A special applications; TB12-TB14 — 0.3A Regulated, 3A special applications • 6.0A (SK-PS6) or 10.0 (SK-PS10) maximum total continuous current for all outputs Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.sitentknight.com SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead -acid batteries only • Float -charge voltage: 27.6 VDC • Maximum current charge:1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0"H x 14.5°W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The SK-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S3511 CSFM: 7315-0559:0522 FDNY Approved FM Approved SK-61095 I C 1 03/21 ©2021 Honeywell International Inc. Honeywell SILENT' KNIGHT Commander Series Selectable Candela Evacuation Signals Applications The GCS/GCC Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current consumption. The GCS/GCC offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The GCC horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone. All tones are easy for the professional to change in the field by using switches. The models are shipped from the factory in the temporal three alarm mode. The GC Series has a very minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander Series comes standard with the 4" mounting plate which incorporates the popular Super -Slide° feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander also features the patented Checkmate° - Instant Voltage Verification feature which allows the installer to check the voltage drop draw without removing the signal. The GC Series appliances are ANSI/UL 464 and ANSI/UL 1971 listed for use with fire protective systems and are warranted for three years from the date of purchase. Standard Features • Nominal voltage 24VDC • Tamperproof field selectable candela options of 15, 30, 75, 95,115 & 150 • Super -Slide° Bracket - Ease of Supervision Testing • Checkmate° - Instant Voltage Verification • Unit Dimensions: 6" (15.24 cm) x 2.6" (6.604 cm) • Synchronize strobe and/or horn with Gentex AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input Terminals 12 to 18 AWG • Switch Selection for High or Low dBA • Switch Selection for 2400Hz or Mechanical Tone • Switch Selection for Continuous or Temporal 3 • Tamperproof re-entrant grill • Surface mount with the GCSB (Gentex Ceiling Surface Mount Box) GCS/GCC 24VDC SERIES ;k t. ; Product Listings SIGNALING OO APPROVED FRViGQ' LISTED • ANSI/UL 464 and ANSI/UL 1971 Listed • FM Approved • CSFM: 7135-0569:122 (GCC) 7125-0569:123 (GCS) • MEA: 285-91-E Patents • 7,375,617 May 20, 2008 Product Compliance • NFPA 72 • Americans with Disabilities Act (ADA) • I BC/I FC/I RC • City & State ordinances/Laws/Regulations • Quality Management System is certified to: ISO 9001:2008 • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white MEMBER ASSEMBLED IN THE USA GCS Series 24 Volt Ceiling Mount Selectable Strobe Model Number Part Number Nominal Voltage Candela GCS24CR 904-1213-002 24VDC 15, 30, 75, 95, 115, 150 GCS24CW 904-1215-002 24VDC 15, 30, 75, 95, 115, 150 GCS24PCR 904-1214-002 24VDC 15, 30, 75, 95, 115, 150 GCS24PCW 1 904-1216-002 1 24VDC 1 15, 30, 75, 95, 115, 150 GCC Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA @ 1Oft. per ANSI/UL 464 In Anechoic Room dBA @ 1011t. GCC24CR 904-1209-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCR 904-1210-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24CW 904-1211-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCW 1 904-1212-002 1 24VDC 1 15, 30, 75, 95, 115, 150 1 81-86 90 Model Designations: C = Ceiling Mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non -returnable. GC24 Product Strobe Current Ratings (mA) Candela 15cd 30cd 75cd 95cd 115cd 150cd 24VDC (16-33 Volts) 24VDC 72mA 101 mA 167mA 200mA 214mA 286mA UL Max' 120mA 120mA 200mA 220mA 290mA 321 mA GCC24 Product Horn Decibel and Current Ratings (mA) Horn Mode Minimum dBA @ 10ft. per ANSI/UL 464 (HIGH) Minimum dBA @ 10ft. per ANSI/UL 464 (LOW) Regulated 24VDC Max. Operating @ High Setting (mA) Temp 3 2400Hz 83 75 23 emp 3 Mechanical 81 73* 22 Continuous 2400Hz 86 78 23 Continuous Mechanical 84 76 22 NOTES: • Operating temperature: 32°to 120°F (0° to 49°C). The GC Series is not listed for outdoor use. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mounting Super -Slide° 3. SNAP COVER OVER ASSEMBLY 2. INSERT LOCKING SCREW �r o �BMWs� a�o4s f • 8 1. SLIDE ONTO BRACKET Checkmate° Instant Voltage Verification Switch Locations D® 0 G°�PdfP - 0 0 o� o O o R E M 0 O s+ �e t H. ® H- x t A 0 FH- (e�w4��D O00o C� � �J o The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTICE: CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. Switch positions 1 and 2 in the down position to select isolated horn and strobe power inputs. Switch 3 selects between temporal or non -temporal tone. Up is temporal. Switch 4 selects between mechanical or high frequency tone. Up is mechanical. Switch 5 selects between high or low dBA. Up is high dBA. GCS/GCC 24VDC S E R I E Conventional GC Series Wiring Diagrams UL Listed Control Signal Signal Panel S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised S S &I B Signal Circuit \ + END OF LINE RESISTOR UL Listed Control SignalMEND Panel S+ S+ S- H+ H-Supervised _77- Signal Circuit \ + OF LINE SISTOR \ + END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (551-0031) AND/OR AVSM CONTROL MODULE MANUAL (550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. Architect & Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output of 90dBA or greater as measured at 24VDC in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 candela strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 29 pounds per carton Important Notice: 551-0051-06 G E N T E X These materials have been prepared Gentex Corporation Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and CORPORATION accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding Fire Protection Products Grou • www. entex.com interpretation of laws, regulations and rules and the application of such laws, regulations and rules to p g particular fact patterns. Each person's activities can differently affect the obligations that exist under 10985 Chicago Drive • Zeeland, Michigan 49464 applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. Commander Series Low GEC/G ES/G E H Frequency Evacuation Signals Applications The Commander' Series is a low profile strobe, horn or horn/strobe combination that offers dependable audible and audible/visual alarms and the absolute lowest current available. The GE Series is available in fixed candela options of 15/75 and 177. The Commander' Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by using switches. The GE Series has a minimal operation current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander' Series is shipped with the standard 4" mounting plate which incorporates the popular Super -Slide° feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander' Series also features the patented Checkmate° - Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The GE Series appliances are ANSI/UL 464, ANSI/UL 1971 and/or ANSI/UL 1638 listed for use with fire protective systems and are warranted for three years from date of purchase. Standard Features • Nominal voltage 24VDC • Fixed candela options of 15/75 and 177 • GEH horn is available in 12VDC or 24VDC • Super -Slide° Bracket - ease of supervision testing • Checkmate° - instant voltage verification • Unit Dimensions: 5" (12.7 cm) high x 4.5" (11.43 cm) wide x 2.5" (6.35 cm) deep • Synchronize strobe and/or horn with Gentex AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input terminals 12 to 18 AWG • Switch selection for high or low dBA • Switch for chime, whoop, mechanical and 2400Hz tone • Switch for continuous or temporal 3 (not available on whoop tone) • Tamperproof re-entrant grill • Surface mount with the GSB (Gentex Surface Mount Box) • Silence horn while strobes remain flashing • Faceplate available in red or off-white 24 VDC SERIES Product Listings SIGNALING �9 �s LISTED ANSI/UL 464, ANSI/UL 1971 and/orANSI/UL 1638 Listed CSFM: 7135-0569:122 (GEH-24 & GEC-24) 7125-0569:123 (GES-24) 7135-0569:130 (GEH-12) MEA: 285-91-E-XV Patents • 7,375,617 May 20, 2008 Product Compliance • NFPA 72 • Americans with Disabilities Act (ADA) • IBC/IFC/IRC • City & State Ordinances/Laws/Regulations • Quality Management System is certified to: ISO 9001:2008 MEMBER `�� �z ASSEMBLED IN THE USA GEH 12VDC and 24VDC Low Profile Evacuation Horn Model Number Part Number Nominal Voltage Reverberant dBA @ 1Oft., per ANSI/UL 464 In Anechoic Room dBA @ 10ft. GEH12-R 904-1239-002 12 VDC 70-82 100 GEH12-W 904-1241-002 12 VDC 70-82 100 GEH24-R 904-1205-002 24 VDC 70-82 100 GEH24-W 904-1207-002 24 VDC 70-82 100 GES 24 VDC Low Profile Evacuation Strobe Model Part Nominal —Strobe Number Number Voltage Candela GES24-177WR 904-1183-002 24 VDC 177 GES24-177WW 904-1203-002 24 VDC 177 15 (ANSI/UL 1971) / GES24-15/75WR 904-1167-002 24 VDC 75 (ANSI/UL 1638) 15 (ANSI/UL 1971) / GES24-15/75WW 904-1187-002 24 VDC 75 (ANSI/UL 1638) W = Wall mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non -returnable. bezel available AGENT bezel available GEC 24VDC Fixed Candela, Low Profile Evacuation Horn/Strobe Model Part Nominal Strobe Reverberant dBA @ In Anechoic Room Number Number Voltage Candela 1Oft., per ANSI/U L 464 dBA @ 10ft. GEC24-177WR 904-1143-002 24 VDC 177 70-82 100 GEC24-177WW 904-1163-002 24 VDC 177 70-82 100 GEC24-15/75WR 904-1127-002 24 VDC 15 (ANSI/UL 1971) / 70-82 100 75 (ANSI/UL1638) GEC24 15/75WW 904 1147002 24 VDC 15 (ANSI/UL 1971) / 70 82 100 75 (ANSI/UL 1638) GE-24 Product Strobe Current Ratings (ill 24VDC (16-33 Volts) Candela 24VDC UL Max' 15/75cd 63mA 67mA 177cd 96mA 213mA GEH-12 Product Horn Decibel and Current Ratings Minimum dBA Minimum dBA Regulated 12VDC Horn Mode @ 1011t. per @ 10ft. per Max. Operating ANSI/UL 464 ANSI/UL 464 High Setting (mA) (HIGH) (LOW) Temp 3 2400Hz 76 69* 29 Temp 3 Mechanical 75 68, 26 Temp 3 Chime 62* 60* 13 Continuous 2400Hz 79 74* 29 Continuous Mechanical 78 72* 26 Continuous Chime 63' 61* 13 hoop 78 71* 55 NOTES: GE-24 Product Horn Decibel and Current Ratings Minimum dBA Minimum dBA Regulated 24VDC Horn Mode @ 10ft. per @ 10R. per Max. Operating ANSI/UL 464 ANSI/UL 464 High Setting (mA) (HIGH) (LOW) Temp 3 2400Hz 78 71 * 28 Temp 3 Mechanical 76 70* 25 Temp 3 Chime 70* 66* 15 Continuous 2400Hz 81 74* 28 Continuous Mechanical 80 72* 25 Continuous Chime 70* 66* 15 hoop 82 69* 56 • Operating temperature: 32°to 120°F (0° to 49°C). The GE Series is not listed for outdoor use. The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12VDC models are DC only. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Tone Switch Locations TONE SWITCH POSITION 3 4 5 Mechanical Temporal 3 ON ON ON Mechanical - Continuous OFF ON ON 24001-lz - Temporal 3 ON OFF ON 24001-lz - Continuous OFF OFF ON Chime - Temporal 3 ON ON OFF Chime - Continuous OFF ON OFF Whoop ON OFF OFF Whoop OFF I OFF I OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON = HIGH dBA • Switch Position 6 OFF = LOW dBA Gentex Super -Slide° Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out Gentex signals without changing mounting brackets and has locking edge connector for snap -in -place GENT�X installation. M j To remove bezel, grip both sides of bezel and pull in a downward and outward motion. H- 0 Gentex Checkmate° Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. GEC/GES/GEH 24 VDC S E R I E Conventional GES/GEC Series Wiring Diagrams UL Listed UL Listed Control Control SignalAJE-. Signal Signal Panel Panel S+ S+ S- H+ H-S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised Supervised 0 S 0 Signal Circuit Signal Circuit \ + + OFLINE -SISTOR ENDOF LINE RESISTOR \ + END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (551-0031) AND/OR AVSM CONTROL MODULE MANUAL (550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. • When synchronizing the GEH 12VDC Series, the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications The audible and/or visible signal shall be Gentex GE Series or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSI/UL 1971, ANSI/UL 1638 and/or ANSI/UL 464. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible and audible units only) shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The appliance shall also be capable of meeting the candela requirements of the ADA (75Cd) for the combination listed (UL 1971/UL 1638) listed models. The appliance shall have an operating current of 67mA or less at 24 VDC for the 15/75Cd for the strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. GENTEX CORPORATION Fire Protection Products Group* www.gentex.com 10985 Chicago Drive • Zeeland, Michigan 49464 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax 6entex Corporation reserves the right to make changes to the product data sheet at their discretion. 24 units per carton 27 pounds per carton Important Notice: 551-0049-02 These materials have been prepared by Gentex Corporation (" Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regu- lations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material.