APPROVED BLD PLN BLD2021-1403+Mechanical_Plan+10.18.2021_12.46.22_PM+2468678ABBREVIATIONS Q� DIAMETER MCA MINIMUM CIRCUIT AMPACITY MECH MECHANICAL AFF ABOVE FINISHED FLOOR MIN MINIMUM AHU AIR HANDLING UNIT MOCP MAXIMUM OVERCURRENT PROTECTION BHP BRAKE HORSEPOWER NC NOISE CRITERIA BDD BACKDRAFT DAMPER NOM NOMINAL BPD BY-PASS DAMPER NO. NUMBER BTU/H BRITISH THERMAL UNIT PER HOUR NTS NOT TO SCALE C CONDENSATE DRAIN PIPING CD CEILING DIFFUSER OA OUTSIDE AIR CFM CUBIC FEET PER MINUTE OBD OPPOSED BLADE DAMPER ODD OUTSIDE DIMENSION OF DIAMETER DB DECIBAL OU OUTDOOR UNIT DH DUCT HEATER DOAS DEDICATED OUTDOOR AIR SYSTEM POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH EER ENERGY EFFICIENCY RATIO EG EXHAUST GRILLE R REFRIGERATION LINES ESP EXTERNAL STATIC PRESSURE RA RETURN AIR EXH EXHAUST RCP REFLECTED CEILING PLAN RG RETURN GRILLE FCU FAN COIL UNIT RPM REVOLUTIONS PER MINUTE FD FIRE DAMPER RTU ROOFTOP UNIT FPM FEET PER MINUTE FSD FIRE AND SMOKE DAMPER SD SUPPLY DIFFUSER SL SOUND LINED GF GAS FURNACE SP STATIC PRESSURE GRD GRILLE, REGISTER, DIFFUSER SM/D SMOKE DAMPER HP HORSEPOWER, HEAT PUMP TG TRANSFER GRILLE HRU HEAT RECOVERY UNIT T'STAT THERMOSTAT HVAC HEATING VENTILATION &AIR CONDITIONING TYP TYPICAL ID INSIDE DIMENSION VAV VARIABLE AIR VOLUME IECC INTERNATIONAL ENERGY CONSERVATION CODE VFD VARIABLE FREQUENCY DRIVE IFR INFRARED HEATER VTR VENT TO ROOF IMC INTERNATIONAL MECHANICAL CODE IN INCH WSEC WASHINGTON STATE ENERGY CODE ISP INTERNAL STATIC PRESSURE ZD ZONE DAMPER LB POUND LVR LOUVER PLAN SYMBOLS � CEILING SUPPLY DIFFUSER � CEILING RETURN GRILLE � CEILING EXHAUST GRILLE new FLEX DUCT � CEILING EXHAUST FAN � INLINE EXHAUST FAN � EXHAUST FAN UP � ROUND DUCT UP � ROUND DUCT DOWN VAV FAN BOX � BALANCE DAMPER (MANUAL) � Fn FIRE DAMPER � Fsn FIRE SMOKE DAMPER �� MOTORIZED DAMPER B ZONE DAMPER � FIRE DAMPER ABOVE DIFFUSER � FIRE DAMPER ABOVE GRILLE OT THERMOSTAT �S SENSOR 0 GAS METER sM SMOKE DETECTOR SD-# SUPPLY DIFFUSER RG-# RETURN GRILLE EF-# EXHAUST FAN TG-# TRANSFER GRILLE - C - CONDENSATE LINE - R - PAIRED REFER LINES Ventilation Schedule # LOCATION Area (SF) KNOWN OCCUPANCY CLASSIFICATION OCC DENSITY / 1000SF CFM /PERSON (Rp) OSA RATE /AREA (Ra) MIN. OSA CFM REQ. KNOWN MIN. EXHAUST CFM REQ. 1 Bathroom 172.5 1 RR/Shower 0.006 0.00 0.00 0 40 2 Bathroom 172.5 1 RR/Shower 0.006 0.00 0.00 0 40 3 Office 2 172.5 2 Office 0.012 5.00 0.06 20 0 4 Office 1 162.5 1 Office 0.006 5.00 0.06 15 0 5 Office 1107 8 Office 0.007 5.00 0.06 106 0 Total 1787 13 142 80 GRD SCHEDULE TAG QTY MAKE MODEL FACE NECK NOTES SD-1 2 SHOEMAKER 104P 24X24 6" SD-2 1 SHOEMAKER 104P 24X24 8" EG-1 2 SHOEMAKER 905 6X6 6" EG-2 1 SHOEMAKER 105P 24X24 8" HIGH WALL HP SCHEDULE TAG MAKE MODEL TONNAGE COOLING CAPACITY (BTU/HR) DESIGN COOLING CAPACITY (BTU/HR) DESIGN HEATING CAPACITY (BTU/HR) SOUND LEVEL dB(A) POWER SUPPLY DIMENSIONS (WxHxD)(in.) WEIGHT (Ibs.) NOTES HW-1 CARRIER 40MAHBQ09XA3 0.75 9000 8500 9000 38 208-1-60 31.3"x11.61"x8.86" 22.71 LBS 1 HW-2 CARRIER 40MAHBQ18XA3 1.5 18000 15000 16000 48 208-1-60 37.99"x12.56"x9.41" 27.12LBS 1 NOTES: 1. REQUIRES A CONDONSATE PUMP OUTDOOR HP SCHEDULE NOMINAL SOUND LEVEL POWER ELECTRICAL DIMENSIONS WEIGHT TAG MAKE MODEL EER /SEER NOTES TONNAGE (dB) SUPPLY (MCA /FUSE) (W x H x D) (in.) (Ibs.) H P-1 CARRIER 38MGRQ48E--3 4 12.5 / 22.4 64 208-1-60 35 / 50 41.15" x 52.48" x 17.63" 223.8 LBS GENERAL HVAC NOTES 1. COMPLETE INSTALLATION OF MECHANICAL SYSTEMS SHALL MEET APPLICABLE CODES PER 2018 IBC WITH WASHINGTON STATE AMENDMENTS, 2018 IMC WITH WASHINGTON STATE AMENDMENTS, & 2018 IECC. 2. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTORS. 3. DUCT INSULATION AND SEALING TO MEET REQUIREMENTS OF SEC C403.10.1 OF THE 2018 WSEC. 4. SYSTEM CONTROLS TO MEET ALL APPLICABLE SECTIONS UNDER SEC C403.4 OF 2018 WSEC. 5. THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND OF 5°F PER WSEC C403.4.1.2. 6. CONTROLS TO BE EQUIPPED WITH AUTOMATIC TIME CLOCK CAPABLE OF STARTING AND STOPPING THE SYSTEM WITH MANUAL OVERRIDE PER WSEC C403.4.2.2 7. OUTDOOR AIR SUPPLY, EXHAUST OPENING, RELIEFS TO BE PROVIDED WITH CLASS 1 MOTORIZED DAMPER AND CLOSE DURING UNOCCUPIED EQUIPMENT OPERATION PER WSEC C403.7.8.1. IF GRAVITY DAMPER, IT SHALL HAVE AN AIR LEAKAGE RATE NOT GREATER THAN 20 CFM/FT^2. 8. VENTILATION BY MECHANICAL OR NATURAL MEANS SHALL BE NO GREATER THAN 150 PERCENT OF THE MINIMUM OA REQUIRED PER WSEC C403.2.2. b ALL ECONOMIZERS PROVIDED SHALL MEET SEC C403.5 OF 2018 WSEC AND BE ABLE TO PROVIDE UP TO 100 PERCENT OSA FOR COOLING PER WSEC C403.5.3.1. 10. SMOKE DETECTORS INSTALLED IN MAIN RETURN PER SEC 606 OF THE 2018 IMC. 11. ALL HVAC EQUIPMENT TO BE LABELED FOR THE SPACE SERVED. 12. DUCTS TO BE SUPPORTED AT EACH CHANGE IN DIRECTION, VERTICAL AT 12'-0" MAX, HORIZONTAL AT 10'-0" MAX WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT 13. ALL SUPPLY GRILLES TO HAVE MANUAL VOLUME DAMPERS FOR BALANCING OF SYSTEM UPON COMPLETION. 14. ALL PIPING TO BE INSULATED ACCORDING TO SECTION C403.10.3 OF 2018 WSEC. 15. FRESH AIR INTAKE AND RELIEF/EXHAUST WILL BE EQUIPPED WITH A LOW LEAK, CLASS 1A MOTORIZED DAMPER THAT AUTOMATICALLY CLOSES DURING UNOCCUPIED HOURS TO COMPLY WITH SEC C403.7.8.1 OF 2018 WSEC 16. GAS PIPING TO BE INSTALLED IN ACCORDANCE WITH THE 2018 IFGC TABLE C404.6 WHEN APPLICABLE. 17. All EQUIPMENT SPECIFIED THE SMALLEST SIZE THAT EXCEEDS THE CALCULATED LOADS PER WSEC C403.3.1. 18. HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 IN 2018 WSEC HAVE BEEN SATISFIED, INCLUDING AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, BALANCE REPORT, AND COMMISSIONING b REPORT. 1 FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5'0" LONG AND STALL MEET INSTALLATION AND MATERIAL REQUIREMENTS OF LOCAL CODES. 20. ALL BRANCH TAKE -OFFS SHALL BE PROVIDED WITH MANUAL BALANCING DAMPERS. G aL� n DUCT HEATER SCHEDULE TAG QTY MAKE MODEL SIZE KW POWER AMPS MOCP CONTROL NOTE DH-1 1 TUTCO ROUND DUCT 8" 1.5 208-1 7.2 0 24VAC 1 NOTE: 1. CONTROLLED BY DUCT STAT SET TO 55 DEGREES ERV SCHEDULE TEMPERATURE RECOVERY EFFICIENCY % ENTHALPY RECOVERY EFFICIENCY % ELECTRICAL AIRFLOW RATE COOLING HEATING COOLING HEATING EXTERNAL STATIC DIMENSIONS WEIGHT TAG MAKE MODEL DESIGN CFM SOUND PRESSURE POWER SUPPLY MCA MOP NOTES (LOW /HIGH) 75% / 100%AIRFLOW 75% / 100%AIRFLOW 75% / 100%AIRFLOW 75% / 100%AIRFLOW PRESSURE (W x H x D) (in.) (Ibs.) ERV-1 DAIKIN VAM300GVJU 170 / 300 150 70% / 65% 69% / 65% 48% / 40% 63% / 57% .64 / .64 21.5 208/230-1-60 1.6 15 34.62 x 12.06 x 31.5 71 LBS 1, 2 NOTES: 1. DOAS SET AT LOW AIRFLOW RATE 2. UNIT TO BE PROGRAMMED TO RUN CONTINUOUSLY DURING OCCUPIED HOURS APPROVED BY PLANNING ���� Oct 28 2021 City Of Edmonds Building Department Work MECHANICAL Address 21010 70TH AVE W Owner MIKES PLUMBING Approved Date 11 /08/2021 Bullding Offlclal , Erg C%c�rte�r Permit Number BLD2021-1403 W� z � C,n - � O Lv O z O O � U U W �_ �_ � z � X m Q w O z a UI RECEIV Oct 18 202 CITY OF EDMOND Z DEVELOPMENT SERVI DEPARTMENT M� W � � �O O W�� ^^ ILL W Q Q - = cn z O O_ � CV W a z O w � � CV C") � L.f) � n 00 z a N o� � � N N � °° J � �� � o J U � Q v m Z � �- Z w � � � � � � o M 0 .0 =D I ES Impact protection will be required if not mounted more than 6' from the ground/ � HVAC DESIGN CEILING LEVEL MECHANICAL PLAN SCALE: 1 /4" = 1'-0" w �� z _w � O O z O O � U U w �� z� � �X � Qm wo _� U' RECEIV Oct 18 202 CITY OF EDMOND z DEVELOPMENT SERVI DEPARTMENT m� W � N W O ^ �"'� >�OoO W Q Q = Cn 0 � O '� Z O O O_ 0 N W a z 0 w � � CV M � Lf� �O I� a0 z Q N O � � N � N � CO J � �� � O J U � Q LU Q � T V m Z Q � � Z W � � � � a � 0 M1 .0 D ES � HVAC DESIGN ROOF LEVEL MECHANICAL PLAN SCALE: 1 /4" - 1'-0" w �� Z _w � O O z O O � U U w �� z� � �X � Qm wo _� U' RECEIV Oct 18 202 CITY OF EDMOND Z DEVELOPMENT SERVI DEPARTMENT m� W � N W O ^ �"'� >�OoO W Q Q = Cn 0 � O Z '� O O O_ 0 N W a z 0 w � � CV (") � L.f) �O I� c0 z Q N O � � N � N � 00 J � �� � O J U Iw- Q W Q m Z Q � � Z W � � � � a � 0 M1 .0 D ES