Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ENG2021-0432 ROW PERMIT REVISION 1
OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds EdmondsRIGHT 980200 4 3�J2 www.cityofedmonds.gov / 425.REVISION 1 Description: PUD-UG PRIMARY SERVICE FOR ODOR SCRUBBER & CHARGING STATION ISSUED: 12/03/2021 Address: 600 3RD AVE S EDMONDS WA 98020 EXPIRES: 06/01/2022 Permit rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 27032600101300 i NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER EDMONDS CITY OF 250 5TH AVENUE N, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $220.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW ENGINEERING DIVISION APPROVED AS NOTED ENGINEERING DIVISION ...,7TED RELEASED BY DATE �?-2t��P �� 12/03/2021 _ p(� G/04/2022 APPROVAL FOR REVISION 1. SEE PAGES 5 FOR REVISED BORING. Printed: Friday, December 03, 2021 8:43:41 AM 1 of 2 -KRWOF WAY EUC PERMIT PERMIT NUMBER City of Edmonds ...• • 1 14 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROL Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. • INSPECTION TYPE DATE RESULT NOTES 1r COMPLETE A 11 JOB START X-2 ENGINEERING FINAL" E-7 TRAFFIC CTRL E-7 RESTOR LIMITS Printed: Friday, December 03, 2021 8:43:41 AM 2 of 2 LIEFMum", Name of Company [P.M... • Primary Name Agent -Name Title Tide Mobile Address Email city State Zip SecondaryName Phone Title Email Mobile City of Edmonds Business License No: Email State License No: -3 `"A., ¢ O(,3 ` EX Contractor verifies it is currently bonded EX Contractor verifies it currently bas general liability insurance .NU L15: A(x(;1U.bo.o2o requires that theAppLication be signed by a Licensed and bonded contractor unless otherwise approved by the city engineer. Type of Development — Check ALL that app]� ❑ Multifamily residential Commercial YCity project Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as well) Traffic Control Only (no associated development) ❑ Utility Franchise Work (no associated development) City of Edmonds ROW construction permitApplication--Page 1 of 3 Updated 3/25/2o2] RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x IF SF Alley 72 hours + IF x IF SF Parldng 72 hours + LF x IF SF SEMON B - If you are not a utility company performing work in the City ROW, -skip to SECTIONC. . The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable ''power o gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have eidsting overhead infrastructure in the area of work? Yes No 2. Will any equipment be added under ound or above ound (e.. pedestals, vaults, etc.)? If yes, describe: aL--) s( v 5 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? 5. Does the work involve proposed additions to an aboveground utility stem? If es: Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e, the actual area in which the 6a. I Does your project I How many are existinz? I I How many are to be added? I I I : ' _ I City of Edmonds ROW construction permitApplication--Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: How mny poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? What is the height of the additional oles? 6c. Are anypoles to be modified/rebuilt/replaced? If yes: How many? What is the height of the poles after? Describe the modification rebuild: _ SECU®N C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every fiagger must be trained as required by WAC 296-155-3o5 and must have certification verifying completion of the required training in their possession, Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to' any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of anyldnd or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectlyfrom any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they maybe liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorizedby owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: L DATE: APPLICANT PRINTED NAME: f_A a""'_, APPLICANT TITLE: �D'r- c NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City ofEdmonds ROW constructionpermitAppheation—Page 3 of 3 Updated 3/25/2091 PRO .�EVE�4PMfNf JChVIUCJUCPH�I�CN� F- N December 2000 Figure 6H-6 Shoulder Work with Minor Encroachment (A-6) ts5_6..Ls A Typical Application 6 Appltcar�t sF�all repair/replace all da mega to uttltttas or fro restage imProye merits tri Ctty rtg l-�t-of-way par Llty star�cfarcls tl-'.at IS cau���G ■ occ s clurt r'rg tt�a Parmltta cl pr4jia� P Page 6H-17 Sect 611.01 � � ■Z ■ ^■ G O ■ V ■ � ■ O ^Jt OV�� •A� ■�IOT�O • -7 2/03/20� -■ sva+ouisx couutr pET[M LAYOUT LEGEND: ® PAD MOUNTED TRANSFORMER ® SUBMERSIBLE TRANSFORMER Q ABOVE GROUND J-BOX Q SUBMERSIBLE J-BOX 05 SECONDARY VAULT PULLING VAULT Q PAD MOUNTED SWITCH CABINET Q SUBMERSIBLE SWITCH CABINET © SMALL SECONDARY PEDESTAL © LARGE SECONDARY PEDESTAL © STREET LIGHT PEDESTAL PRIMARY UNDERGROUND CABLE -•—•—•—•—•-#350 SECONDARY UNDERGROUND CABLE - - - - - - - - 4/0 SECONDARY UNDERGROUND CABLE •••.......•••••.......••• 1/0 SECONDARY UNDERGROUND CABLE --—-—-STREET LIGHT CABLE SERVICE CONDUIT POLE AND OVERHEAD LINE - - PROPERTY LINE —RIGHT-OF-WAY LINE U EXISTING UNDERGROUND CABLE EXISTING DUCT — — — — FUTURE DUCT ------- S------ SANITARY SEWER/MANHOLE ------- D------ STORM DRAIN/CATCH BASIN ------- W------Q WATER MAIN/METER Y FIRE HYDRANT (}; STREET LIGHT * UNDERGROUND LOCATOR MARKER SCHEMATIC LEGEND: • 10 TRANSFORMER 3 0 TRANSFORMER O SUBMERSIBLE TRANSFORMER ❑ 200 AMP J-BOX ■ 600 AMP J-BOX / FUSE PRIMARY UNDERGROUND CABLE ABANDONED PRIMARY UNDERGROUND CABLE OVHD EXISTING OVERHEAD —� �-DISCONNECT SWITCH,NORMALLY OPEN DISCONNECT SWITCH, NORMALLY CLOSED —� STANDOFF BRACKET FEEDER LINE B PULL THRU BOX �— FEED THRU BUSHING ON TRANSFORMER FAULT INDICATOR U ADDITIONAL UGND TAPPED AT T/O POLE VAULT INSPECTION FORM: REFER TO SHEET 2 CONSTRUCTION NOTES: TRANSFORMERS BY PUD OR PUD'S CONTRACTOR A— 5 5 0 1 6 -7-- KVA 12,470-480/277V UTC SER MAKE VAULTS BY CUSTOMER =1671/W 4'8" x 4'8" x 3'6" CONCRETE VAULT AND 4'8" x 4'8" x 6" COVER W/A 3' x 3' DIAMOND PLATE LID A-55016 4'8" x 4'8" x 3'6" CONCRETE VAULT AND 6' x 6' x 6" COVER W/A 40" x 18" ACCESS HOLE CABLE ALL FOOTAGES APPROXIMATE BY PUD OR PUD'S CONTRACTOR ®® v�A., FROM PLI1677 TO A-55015 152' OF (3) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN 4" PVC MAKE PO REEL MAKE PO REEL MAKE PO REEL FT MARK TO FROM A-55015 TO A-55016 32' OF (3)1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN 4" PVC MAKE PO REEL MAKE PO REEL MAKE PO REEL FT MARK TO VAULT LIST VAULT SHEET A-55015 & A-55016 1 A-55017 3 A-55015 A-55017 3-4 WAY 3 300- 2 1 111590 111591 111592 — 111584 PINE ST i..586 AMPSS OVHD 1 OVHD 3 OVHD 2 PLI 1677 SCHEMATIC NTS = 0 2 PUD TO INSTALL 30 PRI RISER ASSY 12U308 ON PLI 1677. EXISTING DIST XFMR BANK ON PLI 1677 TO BE REMOVED ON OPN# 0030. DUCT OA 54' OF 4" PVC (ROAD BORE) BY PUD'S CONTRACTOR pB 2' OF 4" PVC BY CUSTOMER O 37' OF 4" PVC W/(D 90-STEEL ELBOW BY CUSTOMER N �a a 1Ow w .A= K O F c0 p o ,L0 m A— 5 5 0 16 REFER TO LAYOUT FOR ACTUAL DUCT PATH. DEPTHS DEPICTED 75- AT 10'INTERVALS. BORE DETAIL 1 M1587 NTS 111588 111589 0 ---------- A-55015 O — A-55016 --Yr-r------W--___ --==i-`>--_ 7i _ BgORE PIT ---- PINE ST. � N O A _-D----•--' yBORE PIT #2 -- - -----------T --- s PLI 1677-------------- T--------------- 30 OVHD BANK TO P-13621-X I BE REMOVED ON L-19913-X- ORD# 100085398 OPN# 0030 (n W Q 0 Z 04 LAYOUT REVISION 1 APPROVAL V = 20' LOCATION 600 3RD AVE S EMMONDS 98020 AREA LYNNWOOD POLE D PLI 1677 NEWS 26 T 27 R 3 DATE 10/28/21 ORDER 100086398 REASON FOR WORK PROVIDE 30 PRIMARY ENGINEER MCALLISTER OPERATION 0060 UNDERGROUND SERVICE FOR DRAFTER J.SOLVBERG UGNO NO 14461-1 CITY OF EDMONDS APPROVED SCALE NOTED & 50 KW CONN DATE DATE WORK COMPLETED FOREMAN INSPECTOR SUBSTATION WESTGATE CIRCUIT D 12-405 PHASE 1 2 33 DATE FEES REQ'D ■YEs ❑RD ROAD CROSSINGS ONLY PRIMARY OVERHEAD ❑ RESIDENTIAL ❑ COMMERCIAL APPV DATE DESCRIPTION LED. REVISIONS Q._=: APPV NO. DATE DESCRIPTION PRIMARY UNDERGROUND OR SlDENTIAL ❑ COMMERCIAL 1 11/21 ADD SHEET 3 BASIC FEE S LEU- o SECONDARY UNDERGROUND BASIC FEES u S P_ S AS-BUILT0 PRIMARY ❑SECONDARY APPV D. DATE DESCRIPTION FT 0 S = s CL 1 1/22 AS BUILT BORE MISCELLANEOUS FEES DATA VAULT $ PERMIT S CSLER s s S TOTAL DUES DATE PAID RECEIPT. ENGINEER MARY McALLISTER CUSTOMER PAMALA RANDOLF PHONE (425) 670-3216 PHONE (425) 771-0237 N NORTH PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ■ EDMONDS EASEMENTS ❑ REQUIRED E- ❑ NOT REQUIRED REQUEST NO. DATE APPROVED FOREIGN CONTACTS ❑ JPN- ❑ JOINT TRENCH ZIPLY & CATV ❑ JOINT BORE ZIPLY & CATV ■ N/A POLE STENCILING FROM TO TAKE OFF POLE PRE—CONSTR REQUIREMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ❑ ONE CALL DATE STREET LIGHTING ❑ YES ❑ NO MIR AS -BUILT GIS GIS OC M&R GIS Ph JOINT USE _ LOCATION MAP PAGE 454. F7 PRINTED VICINITY MAP REVISION TAGS a z MAR 3 2022 VAULT: A-55015 & A-55016 CABLE: 111584 THRU 111589 ,� e CITY OF EDMONDS rn DEVELOPMENT SERVICES DEPARTMENT SNOMO.4ISH COtrviY pUDo LAYOUT LEGEND: ® PAD MOUNTED TRANSFORMER ® SUBMERSIBLE TRANSFORMER ❑J ABOVE GROUND J-BOX QJ SUBMERSIBLE J-BOX 10 SECONDARY VAULT PULLING VAULT PAD MOUNTED SWITCH CABINET Q SUBMERSIBLE SWITCH CABINET © SMALL SECONDARY PEDESTAL © LARGE SECONDARY PEDESTAL SL STREET LIGHT PEDESTAL PRIMARY UNDERGROUND CABLE -•—•—•—• - #350 SECONDARY UNDERGROUND CABLE - - - - - - - - 4/0 SECONDARY UNDERGROUND CABLE •1•^•^••^•^^•... 1-1/0 SECONDARY UNDERGROUND CABLE ----—-STREET LIGHT CABLE SERVICE CONDUIT o POLE AND OVERHEAD LINE PROPERTY LINE — RIGHT-OF-WAY LINE U EXISTING UNDERGROUND CABLE EXISTING DUCT FUTURE DUCT ------- S------ SANITARY SEWER/MANHOLE -------- D------ O STORM DRAIN/CATCH BASIN ------- W-----'a WATER MAIN/METER Y FIRE HYDRANT {) STREET LIGHT * UNDERGROUND LOCATOR MARKER SCHEMATIC: REFER TO SHEET i VAULT INSPECTION FORM: REFER TO SHEET 4 TRANSFORMER BY PUD OR PUB'S CONTRACTOR A-55017 75 KVA 12,470-208/120V UTC SCR MAKE VAULTS BY CUSTOMER A-55017 4'8" x 4'8" x 3'6" CONCRETE VAULT AND 6' x 6' x 6" COVER W/A 40" x 18" ACCESS HOLE CABLE ALL FOOTAGES APPROXIMATE BY PUD OR PUD'S CONTRACTOR FROM A-55015 TO A-55017 140' OF (3)1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN 4" PVC MAKE PO REEL MAKE PO REEL MAKE PO REEL FT MARK TO DUCT AO 144' OF 4" PVC WITH (2) 45-STEEL BENDS BY CUSTOMER THESE PLANS ARE TO SHOW CONNECTION TO VAULT FOR PARKS DEPARTMENT, NOT FOR CONDUIT IN ROW. SEE PAGE 1 OF PUD'S PLANS FOR APPROVED REVISED ROUTE IN RIGHT-OF-WAY. SEE PAGE 1 FOR BORING ROUTE IN ROW. (CONFIRMED WITH MARY MCALLISTER FROM PUD). A-55015 EXISTING FAW.H.., A Vl - T -------------- ------ -----q - - - - W---------- —1�-- T------------ -W_' PINE ST ' '---D----•-3 PL[1677 ----- ----' -----T--- -------- ---------- f N NORTH LOCATION 600 3RD AVE S EDMONDS 98020 AREA LYNNWOOD POLE NO PLI 1677 NE1/4S 26 T 27 R 3 DATE 11/29/21 ORDER 100078417 REASON FOR WORK PROVIDE 30 PRIMARY ENGINEER Mc ALLISTER OPERATION 0060 UNDERGROUND SERVICE FOR DRAFTER RB UGND No 14461-3 CITY OF EDMONDS PARKS DEPT. APPROVED SCALE NOTED a — 50 KW CONN DATE DATE WORK COMPLETED FOREMM SUBSTATION WESTGATE INSPECTOR CIRCUIT NO 12-405 PHASE 1,2,3 DATE FEES REO'D ■YES ❑No ROAD CROSSINGS ONLY PRIMARY OVERHEAD APPV DATE DESCRIPTION ElRESIDENTIAL ❑ COMMERCIAL LEO- REVISIONS APPV NO. DATE DESCRIPTION PRIMARY UNDERGROUND ❑ RESIDENTIAL ❑ COMMERCIAL BASIC FEE S SECONDARY UNDERGROUND BASIC FEES_ p s Y= s AS —BUILT ❑SECONDARY FT 0 3 = E APPV D. I DATE DESCRIPTION MISCELLANEOUS FEES VAULT 8 PERMIT 8 CSLER s S TOTAL DUES DATE PAID RECEIPT - ENGINEER MARY MCALLISTER CUSTOMER PAMALA RANDOLF PHONE (425) 670-3216 PHONE (425) 771-0237 PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ■ EDIAONDS EASEMENTS ❑ REQUIRED E- ❑ NOT REQUIRED REQUEST NO. DATE APPROVED FOREIGN CONTACTS ❑ JPN. ❑ JOINT TRENCH ZIPLY & CATV ❑ JOINT BORE ZIPLY & CATV ■WA POLE STENCILING FROM TO TAKE OFF POLE PRE-CONSTR REQUIREMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ❑ ONE CALL DATE STREET LIGHTING ❑ YES ❑ NO M&R AS -BUILT GIS GIS QC M&R GIS Ph JOINT USE _ LOCATION MAP PAGE 454. F7 2ND AVE S VICINITY MAP i REVISION c TAGS z a " LAYOUT 20' MAR 3 2022 VAULT: A-55017 o CABLE: 111590 THRU 111592 .7 a CITY OF EDMONDS DEVELOPMENT i ww o SERVICES DEPARTMENT W