Keller SP Lot 1 As-BuiltsSE 1/4, SEC 18, TWP 27N, RGE 4E, W,M, LOT I - KELLER SHORT PLAT (SEE CITY STD DETAIL t i SD-636 ON SHT OT-01) I I I I i I ...�. . . . ....... -------)L -----I I 1 lu 1 / / ► oL 10 I L� i + o 1 0 TOP OF EX CASED CONC. MON. W DOMED I BRASS DISK, SW CORNER NW 1 4 OF SE NV1 I 114 OF SE 114 OF SEC. 18 T27N R4E W.M. , OI 1 ELEV=368.19 I L-I -- -=------- N ❑ \\ \ \ II BUILDING HEIGHT CALCULATIONS (AEG) SPOT ELEVA TIONS FOR HEIGHT CALCULA TIONS. ELEVA TION B. 381. 61 ELEVA TION C. 383.61 ELEVA TION D. 385.33 ELEVA TION A: 382.96 TOTAL: = 1533.51 A VERAGE ORIGINAL GRADE (AOG) = 383.37 TOP OF GARAGE SLAB = 382.50 ROOF A T RIDGE = 40Z 25 ALLOWABLE BUILDING HEIGHT = 408.37 (383.37 + 25 FT) IMPERVIOUS AREAS HOUSE+COVERED D/W, PATIO, PORCH & WALK 2,820 SF (ROOF LINE) UNCOVERED WALK 100 SF UNCOVERED DRIVEWAY 1.230 SF TOTAL = 4,150 SF LOT 1 IMPERVIOUS SUMMARY EXIS77NG IMPERVIOUS SURFACE = 6,004 SF EXIS77NG IMPERVIOUS TO REMAIN = 1,926 SF EXIS77NG IMPERVIOUS TO BE REMOVED/REPLACED = 4,110 SF NEW PLUS REPLACED IMPERVIOUS SURFACE = 4,150 SF NEW IMPERVIOUS SUFFACE = 40 SF LOT COVERAGE LOT AREA: 12,921 SF (LESS INGRESS/EGRESS EASEMENT) 2,999 SF NET LOT AREA 9,922 SF ALLOWABLE COVERAGE (359) 3, 473 SF HOUSE, COVERED DECK AND GARAGE 2,467 SF PERCENT COVERAGE 24. 91 uriuries more 1. ALL NEW UTILITIES ARE REQUIRED TO BE INSTALLED UNDERGROUND. 2. MINIMUM 3FT SEPARA TION REQUIRED BETWEEN DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC) & WET U 17LI TIES (SEWER, WATER, STORM) DR/VEWA Y NOTE DRIVEWAY SLOPES SHALL NOT EXCEED 149. SLOPE PER ECDC 18.80.060 CONSTRUCT/ON NOTE APPLICANT SHALL REPAIR/RELACE ALL DAMAGE TO U77LI77ES OR FRONTAGE IMPROVEMENTS IN CITY RIGHT-OF-WAY PER CITY STANDARDS THAT IS CAUSED OR OCCURS DURING 774E PERMITTED PROJECT. NOTES SITE DEVELOPMENT PLANS I `\ I \ I �- I � \ I SSCO #4 I \ 7R - 379. 4 I 6" lE = 373.5 \ I (SSCO TO HAVE 12" CAST \ I IRON LAMPHOLE COVER WA TER SERVICE I y WITH 1/2" HEX BOLTS) INES 3 FT DEEP (TYP.) POWER II 1N89*07'22" VAULT W 40.01 I \ BUILDING SETBACK LINE L - 1. THE FINAL RESTORATION FOR ALL UTILITY CONNECTIONS AND UTILITY ABANDONMENTS (SEWER, WATER, AND STORM) IS TO BE COMPLETED BY THE CONTRACTOR. A FIELD INSPECTION IS REQUIRED TO DETERMINE THE FINAL RESTORATION LIMITS. STORM DRA/NAGS NOTES IF 774E RIM TO INVERT OF ANY CATCH BASIN EXCEEDS 5 FEET A TYPE H CATCH BASIN WILL BE REQUIRED. SOILS NOTE ALL DISTURBED SOILS WILL BE COMPOST AMENDED PER BMP T.5.13. I I� I I �1 II SSCO #5 I // RIM = 380.4 6 " lE = 374.2 I � I CB SOLID LID RIM = 382.23 4" 1E=380.97 (NW) 55' 4" 1E=380.73 (NW) I r� ♦ 6" 1E=380.82 (W) - - W ♦ 6" 1E=379.88 (SE) (WITH RISER TEE) I I 73'-6" PVC 0=2 \ ® 6.1 Z I I � ♦ � � SD \ SD T 7.5' DRAINAGE & UTILITY I i EASEMENT TO BENEFI T L O T 2 OF KELLER SHORT PLAT � \ (AFN 201809 215002) I I \ Ii ♦♦ 382.46 \ R- \ %I .GONG .. .':!�'� �\ IQ- \ I1 I lYACk' \ II ►\ \ ♦ \ \ I♦♦ i \ I --382-, \J EXISTING GROUND CONTOUR (TYP) N 89 06' 122.00' ------- I_I---�--� -- --�/ r ``------- LEGEND BASIS OF BEARING El EXISTING PAVEMENT TO REMAIN THE MONUMENTED CENTERLINE OF 80TH AVENUE WEST, AS THE BEARING OF NORTH 0045'50" EAST, PER THE PLAT OF SIERRA VILLAGE DIVISION C, AS ❑ ASPHALT PAVEMENT INSTALLED RECORDED IN VOLUME 18 OF PLATS ON PAGE 3, RECORDS OF SNO. CO., WA. AS PART OF SHORT PLAT CONSTRUCTION ElPROPOSED CONCRETE DRIVEWAY BENCHMARK TOP OF EX CASED CONC. MON. W/DOMED BRASS DISK, VISITED: MARCH 2O13 SW CORNER NW 114 OF SE 114 OF SE 114 OF SEC. 18-T27N-R4E W.M. (SEE PLAN) VERTICAL DATUM: NAVD88 ELEV=368.19 LEGAL DESCRIPTION THAT PORTION OF THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 18, TOWNSHIP 27 NORTH, RANGE 4 EAST, W.M., DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHWEST CORNER OF SAID NORTHWEST QUARTER, THENCE NORTH 004550" EAST, 95.01 FEET - THENCE SOUTH 89 0725" EAST, 30.00 FEET TO THE TRUE POINT OF BEGINNING,• THENCE CONTINUING SOUTH 89 0725" EAST, 77.00 FEET TO THE BEGINNING OF A CURVE CONCAVE TO THE NORTHWEST, HAVING A RADIUS OF 77.73 FEE I, - THEN CE EASTERLY AND NORTHEASTERLY, ALONG THE ARC OF SAID CURVE, THROUGH A CENTRAL ANGLE OF 297500 ; A DISTANCE OF 39.68 FEET - THENCE SOUTH 89 0722" EAST, 40.00 FEET - THENCE SOUTH 48'1428" EAST, 84.79 FEET THENCE SOUTH 00'4550" WEST, 49.54 FEET, THENCE NORTH 890602" WEST, 122.00 FEET; THENCE NORTH 00 4550 " EAST, 75.08 FEET, THENCE NORTH 89 0725" WEST, 97.00 FEET; THENCE NORTH 004550" EAST, 20.00 FEET, TO THE POINT OF BEGINNING. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. f9 N2 9f f 67H W SI TE� rT v 200 ST SW _-� 00 T S 2 �1ND ST SW I ` ` r r- ��i �' 1-1 203R ST_ W 204774 ST SW I 99 FT J A MAIN` 2067H ST SW 212774 ST sW o 44 ❑ a h I 2167H�T S Ir �� r� 21 77H4 ST SW VICINITY MAP r • I SCALE. • 1' = 2000' I I I I I I I I SCALE. 1" = 10' 0 5 10 20 PROJECT TEAM OWNER/APPLICANT CIVIL ENGINEER SELECT HOMES RAM ENGINEERING, INC. 16531 13TH AVENUE W. IIA 107 16531 13TH AVE W, SUITE A 108 L YNNWOOD, WASHINGTON 98037 L YNNWOOD, WA 98037 (425) 742-6044 (425) 678-6960 EMAIL: KAYLA.CLARK@OUTLOOK.COM EMAIL: ROBL@RAMENGINEERINGINC.COM CONTACT- KAYLA CLARK CONTACT- ROB L. LONG, PE SURVEYOR ORCA LAND SURVEYING 3605 COLBY AVENUE I EVERETT, WASHINGTON 98201 (425) 259-3400 FAX (425) 258-1616 CONTACT JOANNE SWANSON, PLS SITE DATA I SITE ADDRESS: 19325 80TH A VE W EDMONDS, WA 98026 iLU.lt TAX PARCEL ID NUMBER(S): 270418004OJ500 SI TE ACREAGE: 12,921 SF (0.30 AC) o ,' UTILITY PURVEYORS 6 � WATER SUPPL Y.• CITY OF EDMONDS I 425-771-0235 SANITARY SEWER: CITY OF EDMONDS 425- 771- 0235 STORM SEWER. CITY OF EDMONDS 425- 771- 0235 I 1 PHONE. FRONTIER ` 425-263-4024 l CABLE: COMCAST I - 425-244-5088 i GAS. PSE 888-225-5773 POWER: SNOHOMISH COUNTY PUD 425- 783-1000 FIRE DISTRICT. SNOHOMISH COUNTY FIRE DISTRICT NO.1 425-551-1200 SCHOOL DISTRICT: EDMONDS SCHOOL DISTRICT 425-670-7000 SHEET INDEX RAM ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE Al08 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM m, - � E � - � �� - � 2 co O w y� W W O O J o ~ U 04 W O j I� W W cn W I cn ti o U) J J QLO N 0 c \ N ZI- INInI"j-ILo � � 6w crs10 IO1veT. V �-.0I 1 SP-01 SITE DEVELOPMENT PLAN 2 GN-01 GENERAL NOTES & LEGEND 1219119 3 TP-01 CLEARING, GRADING & TESC PLAN ENGINEER. 4 DT-01 STANDARD DETAILS ROB L. LONG, PE AS -BUILT DRAWN BY.• MIKE MORRIS BLD2018-0948 Know what's below. Call before you dig. ISSUE DATE.SCALE: 7111118 AS NOTED JOB NO. 18-014 SHEET.• SP-01 SHT 1 OF 4