Loading...
BLD2022-0300_Other_3.9.2022_1.11.32_PM_2727693--- ------------ --� String 1 — +/ z 11 modules + o U z String 2 U o � 10 modules + String 3 � 10 modules + A B 0 Equipment Schedule I— I I I I I I I I Line o O Load �-------- E> Located less than 10' from net meter and less than 10' from tap I I G)L--------- Customer Owned Production Meter 0 Ref. Category Equipment QTY 1 Modules Silfab ELITE - SIL-BK 380 31 2 Optimizers P401 SolarEdge Optimizer 31 3 Jbox Jbox 5 41 Inverters Solar Edge SE10000H 1 5 MeterBase MeterBase-125A 4 Jaw w/ 3.5" AWCAP 1 Meter Landis Gyr EA110000-OP29 240V 1 6 Disconnect 60A 240V 2 Pole I Heavy Duty, Fuse, Lockable 1 DisconnectFuse FLNR - 60 A Fuses for Disconnect (qty 1 /pole) Monitoring SolarEdge Integrated (inverter) Monitoring 1 0 Conductor Schedule Supply Side Connection 705.11 (Existing) Main Service Panel (1ph 240V Service) Main Breaker: 200A Bus Rating:200A I I I L---.4 #6 GEC I Neutral Bar w/ bonding jumper ■=A&RScope `„I' = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT O OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. nverter Specs Watts LW-1 Output � AC Voltage # of Inverters OCPD Solar Edge SE10000H 10000 42 240 1 60 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w Imp Vmp Voc Isc Silfab ELITE - SIL-BK 380 380 9.79 38.88 45.13 10.5 Temp. Adjusted 0 0 35.2 49.2 0 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop Volt. Drop (total) A (2)#10 CU, (1)#6 EGC, PV Wire 60OV, AIR 50 18.75A 400V 0.33% 0.99% B (6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) 50 18.75A 400V 0.33% C (2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 52.5A 240V 0.17% D (2)#6 CU, (1)#6 N, THWN-2, 1"PVC(min) 10 52.5A 240V 0.17% General Notes: = Q a0 -�e 0 O O O o0- 01U� C? W a 00 -a U >� �N� O cn ^ z cn N N 0 ko E LO co -0 REVISIONS Rev. #: IDate: Utility: Snohomish PUD IDesigned by: Thomas N 1. EGC Where exposed to physical damage will be #6AWG Project Manager: Bare CU Will MacArthur 2. If installing conduit on the roof, maintain greater than 7/8" (206) 307-1741 above the surface 3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Current Date: Mar 08, 2022 Disconnect 4. For supply side taps, a #6 GEC (min.) will be run separately from the disconnect and connected to the grounding electrode E1 Single Line with an irreversible crimp PV Electrical Calculations Inverter Specs Watts (W) Output AC Voltage # of Inverters OCPD Total AC Comb. EGC AC out.(A) OCPD Solar Edge SE10000H 10000 42.00 240 1 60 42.0 60 410 P Ampe ****N/A**** 0 0.00 0 0 0 ****N/A**** 0 0.00 0 0 0 Module Specs at Watts IMP Vmp Voc Isc Temp. Coef V(oc) DC Volt Silfab ELITE - SIL-BK 380 380 9.79 38.88 45.13 10.50 -0.279 #10 Max Vc Max I Temp. Adjusted t--l35.2 49.2 Optimizer? P401 SolarEdge Optimizer Max current output: 15A, Max Voltage: 480V Equipment Solar Edge SE10000H ****N/A**** ****N/A**** Mppt Input 1 1 2 1 3 1 1 2 1 3 1 2 F 3 Module Silfab ELITE - SI L-BK 380 ****SELECT**** ****SELECT**** # Modules per String 11 10 0 0 0 0 0 0 0 # Strings 1 2 0 0 0 0 0 0 0 # of Mods per group 11 20 0 0 0 0 0 0 0 # of Mods/inverter 31 0 0 # of Inverters 1 0 0 Total # of Modules 31 Ref. Conductor Description A (String) to Jbox B Jbox to Inverter C Inverter to Disconnect D Disco. to Interconnect E F G H Arrav Specs (Adiusted for Temperature Inverter 4pptInput -age (Imp) age (Vmp) Solar Edge SE10000H 1 2 3 10.47 9.52 0.00 400.0 400.0 0.0 ****N/A**** 1 2 3 0.00 0.00 0.00 0.0 0.0 0.0 ****N/A**** 1 2 3 0.00 0.00 0.00 0.0 0.0 0.0 iltage(DC) 480.0 480.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 kmps (DC) 15.00 15.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Max Array Power(STC): 11.78 kW DC Max Continuous AC Power: 10kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI lowed 40 PV OCPD Device Used 60 Tap or Breaker? Tap ,tance AL CU Wire Gauge (QTY) Phase Neutral Neutral EGC (AWG) Wire Type Conduit Min. Conduit 90°C Rating Temp Correct. Fill Derate Derated Ampacity Conductors AWG (QTY) Type 50 Cu #10 2 N/A N/A #6 PV Wire 600V AIR N/A 40 1 100% 40.00 50 Cu #10 6 N/A N/A #10 THWN-2 EMT 0.75 40 1 80% 32.00 10 Cu #6 2 #8 1 #10 THWN-2 EMT 0.75 75 1 100% 75.00 10 CU #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 Site Conditions ASHRAE Site: Seattle Low Temp (°F) 19 High 2%Temp (°F) 84 High 0.4%Temp ff) 91 75T I Current I Operating I Voltage �1/1,A. .4 A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE JNFIDENTIAL INFORMATION OF A&R SOLAR ND ITS RECEPTOR. POSSESSION DOES NOT )NFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. =a 0 0 0 � E -�e o o a) oo Lr) CY) 0-a E CD a) a Q > U Ln N Ln G) ^ >� `1 u Ln � to o w a� 35 18.8 400 0.33% 35 18.8 400 0.33 % 65 52.5 240 0.17% REVISIONS 65 52.5 240 0.17% Rev. #: Date: Designed by: Thomas N Project Manager: Total Voltage Drop: 0.99% Will MacArthur (206)307-1741 Current Date:Mar 08, 2022 E2 Electrical Calculations