BLD2022-0308_Manufacturer_Specifications_and_Installation_Instructions_3.10.2022_1.07.51_PM_27302780 TRANS°
Product Specifications
OUTDOOR UNIT (a) (b)
4TTL6036A1XXXA
HIGH SPEED COOLING CAPACITY@
80/67-95(Btuh)
35000
POWER CONNS. — V/PH/HZ (c)
208/230/1/60
MIN. BRCH. CIR. AAPACITY
19
BR. CIR. PROT. RTG. — MAX. (AMPS)
30
COMPRESSOR
CLIMATUFF®- SCROLL
NO. USED — NO. STAGES
1 — 1
VOLTS/PH/HZ
208/230/1/60
R.L. AMPS (d)— L.R. AMPS
14.7 — 75
FACTORY INSTALLED
START COMPONENTS (e)
NO (Uses BAYKSKT263)
INSULATION/SOUND BLANKET
NO
COMPRESSOR HEAT
NO
OUTDOOR FAN
PROPELLER
DIA. (IN.) — NO. USED
27 — 1
TYPE DRIVE — NO. SPEEDS
DIRECT— 1
CFM @ 0.0IN. W.G. M
3150
NO. MOTORS — HP
1-1/8
MOTOR SPEED R.P.M.
850
VOLTS/PH/HZ
200/230/1/60
F.L. AMPS
0.67
OUTDOOR COIL — TYPE
PLATE FIN
ROWS—F.P.I.
2-16
FACE AREA (SQ. FT.)
12.88
TUBE SIZE (IN.)
5/16
REFRIGERANT
LBS. — R-410A (O.D. UNIT) (9)
6 LBS., 3 OZ
FACTORY SUPPLIED
YES
LINE SIZE — IN. O.D. GAS (h)
3/4
LINE SIZE — IN. O.D. LIQ.
3/8
CHARGING SPECIFICATIONS
SUBCOOLING
10°F
DIMENSIONS
H X W X D
CRATED (IN.)
40.88 x 54.5 x 23.0
WEIGHT
SHIPPING (LBS.)
242
NET (LBS.)
215
(a) Certified in accordance with the Air -Source Unitary Air -conditioner
Equipment certification program, which is based on AHRI standard
210/240.
(b) Rated in accordance with AHRI standard 270.
M Calculated in accordance with Natl. Elec. Codes. Use only HACR
circuit breakers or fuses.
(d) This value shown for compressor RLA on the unit nameplate and on
this specification sheet is used to compute minimum branch circuit
ampacity and max. fuse size. The value shown is the branch circuit
selection current.
(e) No means no start components. Yes means quick start kit
components.
M Standard Air — Dry Coil — Outdoor
(e) This value approximate. For more precise value see unit nameplate.
(h) Max. linear length 150 ft.; Max. lift — Suction 50 ft.; Max. lift — Liquid
50 ft. For greater length consult refrigerant piping software Pub. No.
32-3312-0* (* denotes latest revision).