1579_001Advanced Blower Door Test Co.
Blower Door Test Results
Curleata Reykdal -Owner
425-870-1837
Permit #:
Date of Test:
Technician Name:
Age of house:
House address: N -10 V)gce :!�->.
City: �jimom< Zip:
Test Target: 6.0
Conditioned Scl Footage: 30
Volume: SO , o(jo
Ring (check one if applicable): Open
Blower Door Location: 0-6
C`
ae
ACH: 9 2_
CFM: 2-I3Z
A_ C� B
Weather Condition:
I certify that these blower door results are accurate and determined using standard industry protocol.
Date: 5 0
a� Technician Si nature:
g
2015 Washington State Energy Code reference:
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be
conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals). Where required by the code official, testing shall be conducted by an approved third party.
A written report of the results of the test shall be signed by the party conduction the test and provided to the code official. Testing shall be performed at any time
after creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed sealing (see Table R402.2.1.1), operable windows and doors
manufactured by small business shall be permitted to be sealed off at the frame prior to the test.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weather-stripping or other
infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures. 3. Interior doors, if installed at the time of test, shall be open, access hatches to conditioned crawls space
and conditioned attics shall be open. 4. Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and
sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the
time of the test, shall be fully open.