Loading...
BLD2022-0248_Manufacturer_Specifications_and_Installation_Instructions_2.25.2022_2.01.43_PM_2703654EverVo t I EVERVOLT- SOLAR MODULE SERIES The Panasonic Advantage 6. ; Higher Module Efficiency � Superior module efficiency of 21.2%and 20.6%, � respectively, allows maximum power production with Less roof space. With one of the industry's Lowest annual degradation rates, power output of at least 92% is guaranteed after 25 years. r� TripteGuard 25-Year Warranty' A Long-term warranty is only as reliable as the company behind it. TripLeGuard covers EverVolt panels for performance, product, parts and Labor for 25 years. Whether in year three or year 25, your Panasonic warranty will be there when you need it. High Efficiency in High Temperatures Produce more energy throughout the day even on the hottest days in the warmest climates. EverVolt solar panels outperform others when temperatures rise due to our industry -leading 0.26%/°C temperature coefficient. aeo Heterojunction Cell Technology ODO Half -cut cells with heterojunetion technology minimizes electron Loss, maximizes conversion efficiency, and produces considerably higher power output over conventional panels. Durability & Quality Assurance N-type cells result in minimal Low Induced degradation (LID) and Potential Induced degradation (PID), which supports reliability and longevity. As a solar pioneer for over 40 years, Panasonic EverVolt solar panels are backed by innovation, experience and a brand you can trust. p® Improved Performance When Shaded Continuous power production in shaded areas for greater energy yields and output. More sunlight absorption means more clean power to your home. Panasonic PRELIMINARY TRIPL WARRANGUATYRD EverVof f I EVERVOLT' SOLAR MODULE SERIES ELECTRICAL SPECIFICATIONS Ratetl Gower Pmavl' M«imumPowzrvettege lypmj 370W 37.N 360W 3T.W Maximum Power Current Ilpml 981 1,72 opennma,gvaMgewrcl 66.1 aa.o Shan cirt�e current list' Temperature Ccemrient lPm«I tD.d2 7 26 %/.c 10.57 Temperature CoemcienllPo 1 -0.26%/-C Temperature Caemclent 1l 1 0.04 V-C NOCT 44`C M-Cl CECRTCRaling Moeule Erhnanry an 1111 TDD 2— MinimumsyslemVRlla9e Im Maximum Series Fuse 25A Wm Claes6oning -0/.5 MECHANICAL SPECIFICATIONS Jnm'IIaR aM D-wn,3bFe:a moaaa.l��ipralaa Canne Type a na Staubti MC4 PV-NDT4/1(51411 mmxlnw ee tabu Size/Typo dmrrP sr,Wr� .. Lo my. 1.2m m xm•aaxtw'uEr+smle Max Snow Loatll•P 166 Ps170W Pal• Mat WIM Load I-Ir B3 P.16000 Pal' Dimensions txwaH 67.Bx 40.0. 1.2 m(1721. 1011 a W mml Wepht "O Ws Ills I,gl Panel Dimensions 4WxH 70x 42. 681n 0uantity per PailN/ Pauer weyM 33.pg,1151216s.1606 k91 Ouant4ry 40'Canlainer 858 pcs 'ram wa.Oaapnl<aaab«IaxmauiplleagawnlM OPERATING CONDITIONSAND SAFETY RATINGS Certlllutlwm IEC 612161016, IEC 61730:2016, 9L 1703i UL 61730, IEC 62Md IW01 IEL 617111 ISaOMistl. IEC U716I %.i—,L t5 "W1 211g wh'ryCfa«El. DNI 9657NI 7E lt9neablhryLMu lL IEC 62782 IDynamic Merheniral Loael. IEC 61215-2.2D16IHailemne 35mm1, A5606L2 Nec 2016Icydir Wine laud' operating Temperature -40^Ft. 185-F 1-4Oic to 85• 1 Limited Warmnly 2TYy WwNmanshipand Power Ou1pu11Linear " Power 0u1put In Year 1 99% Annwt negraeati.. 0.25% Power ...palm Year25 92% Panasonic PRELIMINARY PERFORMANCE WARRANTY IL p F MPatuMnit �Gnventional m � DIMENSIONS mu.n ❑ f� 9 e $ kal y g9g 8 G ■ - ;3p asns vsWW + M««,am«mi�mm na DEPENDENCE ON IRRADIANCE tx I99ow ma 1p BWW/mr t 6WW mr p 1a M YeOege MM M w NNE —,Ix d 1.1reaelemNn a.rma�­ 5 d.am 1Oe /m2.1.m«mw,.2aabl�� .n a C E 0 •• stallation ne bbemme) I N�u9t demix F ehiMaran awmxiNin 60dgy1m .... ecno...... oin,ormaoonanm w mou, nwire. Itsleye. a un r LCAUTIONI Please read the nstalWIN, manual c M[y 1,0o using the products. Rq'- arylWrea Fa n60 days tmnry-fivz bSly«r Tnlplaf aAwalmmy, a«,mend reco.ervaaarecrcl�coatolaoroauc�s,oma.+r,axa e�.m,oaoot�raaly coltenm�uo�ms�a CONTRACTOR INFORMATION NATIONWIDE SOLAR 5619 MILWAUKEE AVE E, PUYALLUP WA 98372 CSLB# AAAMEAE913DC PHONE: 2537224782 Email. cbitton9lt�comcastnet Nationwide :• SOLAR♦ .... NATIONWIDE SOLAR 6407 NE 117TH AVE. SURE B VANCOUVER, WA 98662 PH ONE'.(800) 908-8992 Email: getsdar�mrnationwidespleccpm VERSION DESCRIPTION DATE REV INITIA-RELEASE101118-1 UR PROJECT NAME D Q } Cn CD Z ❑ LLLL 0 O D O 0 CD CD r Z�D)oU❑ L LL.I fY] >Q LL m Q > 0 I.—_ F.- U) 0O =ry } m N Z it Z U LL ❑ Q } Q W � J F_ SHEET NAME SPEC SHEETS ANSI B 11" X 17" SHEET NUMBER PV-10 Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and I 7+ Microinverters To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy, Enphase IQ Battery', and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014&2017) Productive and Reliable Optimized for high powered 60-cell/120 half -cell and 72- cell/144 half-cell+modules More than a million hours of testing Class It double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) "The IQ 7+ Micro is required to support 72-ceIV144 half -cell modules v EN PHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module paidngs' 235W-350 W+ 235W-44 W+ Module compatibility 60-cell/120 half -cell PV modules 6C-cell/120 half -cell and 72- only cell/144 half -cell PV modules Maximum input DC voltage 48V 60V Peak powertracking voltage 27 V-37 V 27 V -45 V Opsmungmnge 16V-48V 16V-60V Min/Max startvoltage 22V/48V 22V/60V Max DC short circuit current(module Isc) 15A 15A Overvcltageclass DC port II II D, port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 MIcrolinn rter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maxim um continuous output power 240 VA 290 VA N—mail(L-L)voltage/range' 240V/ 208 V/ 240V/ 208V/ 211-264 V 183-229 V 211-264 V 183.229 V Maximum continuous output current 1.0A(240 V) 1.15A(208V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 H. Extended frequency range 47-68 Hz 47-68 HZ AC short circuit faulfcurrent over 3 cycles 5.SArms 5-6 Arms Maximum units per 20 A (L-L) branch circuit- 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Ambient temperature range -40eCto+65"c Relativehumidity range 4%to 100%(condensing) Cannectortype MI (or Amphehol H4 UTX with additional Q-DCC-5 adapter) Dimensions(HxWxD) 212 mm x 175 mm x30.2 mm(without bracket) Weight 1.08 kg (2.381bs) Cooling Natural convection- No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class ll double -insulated, corrosion resistant polymeric enclosure Environmental category/ UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnedting means The AC and 0C connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Pert ISCless B, ICES-0003CIass B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of Pi/Systems, for AC and DC conductors, when installed according manufacturer's instructions. I- No enforced DC/AC ratio. Seethe compatibility cal-Iii rat Mtna//ennhase comlemus/stport/module-comnat h'Iity. 2. Nominal voltage range can be extended beyond nominal If required by the utility. 3. Umes may wry. Refer to local requirements to define the number of minroinwrters per branch in your area. To learn more about Enphase offerings, visit anphase.com v EN PH AS E. 02020 Enphase Energy. All.,ghts reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQEnvoy, and othrrtcdema ar service nemes arethe UademI of Enphase Energy,Inc. Data subject. Chenge. 2020-08-12 CONTRACTOR INFORMATION NATIONWIDE SOLAR 5619 MILWAUKEE AVE E, PUYALLUP WA 98372 CSLB# AAAMEAE913DC PHONE: 2537224782 Email: cbitcn911@wmcast.net Nationwide - SOLAR♦ ... NATIONWIDE SOLAR U07 HE I I 11 AVE. SURE B VANCOUVER, WA9e662 PHONE'. (800) 908-6992 Email: ii—larlgmynznnnw d—lar.cam VERSION DESCRIPTION I DATE I REV INITIAL RELEASE 01118r2022 UR PROJECT NAME D U o Z LLLL 0 O D O O o O 2 N U WCDCD 0 2 LLJ m Q � U) m Q Lo W O O O ❑ Z It 00010 Z (n IY a H LLI J SHEET NAME SPEC SHEETS ANSI B 11" X 17" SHEET NUMBER PV-11 Z O 2 Lu ILL O F_ U Q Data Sheet Enphase Networking Enphase IQ Combiner 3 (X IQ-AM1-240-3) E To learn more about Enphase offerings, visit enohase.com The Enphase IQ Combiner 3' with Enphase IQ Envoy' consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes lQ Envoy for communication and control • Flexible networking supports WI-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMAtype 3R enclosure • Five-year limited warranty UL listed n ENPHASE. Enohase 10 Combiner 3 MODELNUMBER IQ Combiner3 lQ Combiner 3 With Enphase IQ Envoy` printed circuit board for integrated revenue grade PV X-IQ-AMl-240-3 production metering (ANSI C12.20+y- 0.5%) and optional- consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect'" CELLMODEM-03(4G/12-year data plan) Plug and play Industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01(3G/5-year data plan) microinveners.(Available in the US,Canada,Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring- CT Split core current transformers enable whole home consumption metering(+/-2.5%). CT-200-SPLIT •eon: in, E,gh-9mrage sr:mms rro—m .-,i—qui,aa Wireless USB adapter Installed at the IQ Envoy. For communications with Enphase Encharge- storage and Enphase COMMS-KIT-01 Enpower"smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner - and allows redundant wireless communication with Encharge and Enpowet Circuit Breakers Supports Eaton BR210, BR215. OR220, BR230, BR240, BR250, ano OR260 circuit breakers. all OA-2.240 Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole,15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power fine carrier (communication bridge pair), quantity - one pair XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 1201240 VAC, 60 Hz Eaton BR series bulbar rating 125A Ma x. continuous c urren t red ng(output to grid) 65A Max. fuse/circuit rating (output) 90A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG) breakers only (not included) Max. continuous current tell ng(input from PV) 64A Max. total branch circuit breaker rating (input) BOA of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre -installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 37.5 x 16.8 crrl (19.5' x 14.75' x 6.63"). Height is 21.06' (53.5 ern with mounting brackets). Weight 7.5 kg (16.5 lbs) Ambient temperature range -40e Cto+46°C(-40°to 115-F) Coaling Natural convection, plus heat shield Enclosure environmental rating Outdoor,NRTL-certified, NEMA type3R, polycarbonate construction We sizes 20 A to 50 A breakerinputs: 14 to 4 AWG copper conductors • 60 A breaker branch in put: 4to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14to 1/0 copper conductors Always follow local code requirements for conductor sizing. f,hiludz To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.111,11 Ethernet Optional, 802.3, Ca15E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01(Sal or CELLMODEM-03 (40) or CELLMODEM-M1 (4G based LTE-M) not Included COMPLIANCE Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 1071, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5(PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22,2 No. 61010-1 To learn more abort Enphase offerings, visit enphase.com 02narka of 01Enphase Energy.AllfiEnergy, M Cresevved. Enphase the Enphase logo, IQ Cembiner 3, and other trademarks or service names are the trad201411-04 " I. EN PHASE, CONTRACTOR INFORMATION NATIONWIDE SOLAR 5619 MILWAUKEE AVE E, PUYALLUP WA 98372 CSLB# AAAMEAE913DC PH ONE: 2537224782 Email: cbM,n9llOwmcast.- Nationwide: SOLAR NATIONWIDE SOLAR 6407 NE 117TH AVE. SURE B VANCOUVER, WA 98562 PHONE: (800) 90e8992 Email: getaolar�mynationwitleaolar.com VERSION DESCRIPTION DATE REV INITIALRELEASE n1/18Y2n22 UR PROJECT NAME a Q O Z 0 L~L O D O O N CDU o LU CO >QU) LL m Q> 1- O Q H H f) O = i Lu Q CDF N cZ U Z 0 0 Q Q LLJ J_ SHEET NAME SPEC SHEETS ANSI B 11" X 17" SHEET NUMBER PV-12 CONTRACTOR INFORMATION NATIONWIDE SOLAR 5619 MILWAUKEE AVE E, PUYALLUP WA 98372 CSLB# AAAMEAE913DC Data Sheet Enphase Q Cable Accessories PHONE: 2537224782 Enphase Q Cable Accessories Entail: cbM.h9110_..c.xt.h.1 REGION. Americas CONDUCTOR SPECIFICATIONS Nationwide: Certification UL3003(rawcalle).UL9703(cable assemblies),DGcable SOLAR Flametestrating FT4 p Compliance RoHS, OIL RES I,CE, UV resistant, combined UL for the United States Conductor type THHN/THWN-2dry/wet ^""" ` "•""""'"' Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL far use as the load -break a NATIONWIDE SOLAR 6407 NE 117TH AVE. SURE B Enphase The Enphase Q Cable" and accessories are part of disconnect required by NEC 690. VANCOUVER, WA 98662 the latest generation Enphase IQ System-. These QCABLE TYPES/ ORDERING OPTIONS PHONE: (800)908-8992 Entail: geteolar@ntynationwideaolar.00m Q Cable Accessories accessories provide simplicity, reliability, and Faster Connectorized Models Size/ Max Nominal Voltage Connector Spacing WModule Orientation ConnectorContper Boor Q-12-10-246 12 AWG/277 VAC 1.3 m(4.2 ft) Portrait 240 VERSION DESCRIPTION I DATE REV installation times. Q-12-17-240 12 AWG/277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 INITIAL RELEASE 01/18/2022 UR Q-12-20-200 12 AWG/277 VAC 2.3 m V..5 ft) Landscape(72-cell) 200 ENPHASEQ CABLE AC CESSORIES Name Model Number Description u9i To learn more about Enphase offerings, visit enphose.com Enphase Q Cable • Two -wire, double -insulated Enphase Q Cable is 50%lighter than the previous generation Enphase cable • Newcable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cablewaste Field-Wireable Connectors • Eas lly connect Q Cables on the roof without complex wiring • Make connections from any open connector and center feed any section of cable within branch limits • Available in male and female connector types '-I ENPHASE Raw Cable Q-12-RAW-200 300 meters of 12 AWG cable with no connectors Field-wireable connector(male) Q-CONN-10M Make connections from any open connector Field-wireable connector (female) Q-CONN-101` Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cablingtothe racking orto secure looped cabling Disconnect tool O-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Cable sealing caps (female) Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator gTERM-10 Terminator cap for unused cable ends Friends PV2 to MC4 adaptor ECA-S20-S22 Connect PV module using MC4 connectorstu 10 micros with Friends PV2 bulkhead connectors Friends PV2 to UTX adaptor ECA-S20-S25 Connect PV module using UTX connectors to IQ micros with Friends PV2 bulkhead connectors Replacement DC Adaptor (MC4) Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX) Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) TERMINATOR unused cable Termends, SEALING CAPS Sealing aggregator ends, sold in packs often sold in packs ble come Lions and cable connections (0-TERM-10 (0-BA-CAP-10 and Q-SEAL-10 DISCONNECT TOLL Planto use at least oneper f,� CABLE CLIP Used to fasten cablingtothe racking installation, sold in packs often orto serum looped cabling sold in (0-DISC-10) packs of one hundred (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com c 0201E Enphase Energy. All nghs ssa,ve l al Vadernaft a brand, — are the propem or Ehrhese Energy, Inc. ENPHASE. 2016-05-24 V PROJECT NAME a to CD z L~0 L (9 C:)p D O CD o O 2 00 N CD U �O°' CD 25 LU CO Q ',I-- Ib Q CY) Un IS W rn I) CD O z OcoOZcn Q Q L L] J_ SHEET NAME SPEC SHEETS ANSI B 11" X 17" SHEET NUMBER PV-13