BLD2022-0379_Other_3.25.2022_2.17.09_PM_276237359TP6B Performance TM96 Two -Stage, Variable Speed Non -Communicating, 4-Way Multipoise 35-in. (889 mm) Tall Condensing Gas Furnace Product Data A11263 The 59TP6B Multipoise Variable -Speed Condensing Gas Furnace features the two -stage Performance TM System. The Comfort Heat® technology two -stage gas valve is at the heart of the comfort provided by this furnace, along with the variable -speed ECM blower motor, and two -speed inducer motor. With an Annual Fuel Utilization Efficiency (AFUE) up to 96.5% AFUE, the Performance TM Series two -stage gas furnace provides exceptional savings when compared to standard gas furnaces. This Performance Gas Furnace also features 4-way multipoise installation flexibility, and is available in nine model sizes. The 59TP613 can be vented for direct vent/two-pipe, ventilated combustion air, or single -pipe applications. All sizes are design certified in Canada. This furnace is not designed for use in recreation vehicles, manufactured (mobile) homes or out doors. PERFORMANCE • Variable -speed, constant -torque ECM blower motor, two -speed inducer motor, and two -stage gas valve. • Fully -insulated casing including blower section. • Aluminized -steel primary heat exchanger. • Stainless -steel condensing secondary heat exchanger. • Silicon Nitride Power HeatTM Hot Surface Igniter. Performance - SERIES i Turn to the experts • Adjustable blower speed for heating, cooling, continuous fan, and dehumidification. • Ideal Humidity SystemTM Technology for dehumidification performance. • Comfort Heat Technology® feature intelligently stages heat and removes air stratification between rooms and within rooms • Comfort FanTM technology allows control of continuous fan speed from a compatible thermostat. INSTALLATION FLEXIBILITY • 4-way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through - the -cabinet downflow venting capability. • Factory -configured ready for upflow applications. • Installation flexibility: sidewall or vertical vent. • Ideal height 35" (889 mm) cabinet: short enough for taller coils, but still allows enough room for service. • Direct-vent/sealed combustion, single -pipe venting or ventilated combustion air. APPLICATIONS • HYBRID HEAT® Dual Fuel Compatible • Convertible to propane with gas conversion accessory kit. • Convenient Air Purifier and Humidifier connections. • Twinning capable with accessory kit. • 5 ton sizes allow 15 Amp breaker with assessory (order sparately). • SmartEvapTM technology prevents condensate that remains on the coil after a dehumidification cycle from re -humidifying throughout the home CERTIFICATIONS • All sizes meet ENERGY STAR Version 4.1 criteria for gas furnaces: 95.0%+ AFUE. • Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193. • All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirement Gy p icf )I` SP SN IPA IS09001 FRTIF���® CERTIFIED O Quality 0t�y5�41(q�� 4 y Useof11¢ 1Ca d �MukirMkalec. �pa p.alcl.✓ '1, M. 'In Pm'.. Far verlflc.tlon fa.rGfi Iw in6vidid F p 0 —.1 1 wrmi� an.�mryao. A200322 59TP613: Product Data RATED CASING HEATING AFUE HEATING AIRFLOW DIMENSIONS (IN.) OUTPUT COOLING FURNACE SIZE (BTUH) ENERGY CFM @ 0.5 MOTOR High STAR® ESP HP H D W High Low UPFLOW/HZ DOWN CFM (High CFM (LOW Heating (in. W.C.) -FLOW Heating) Heating) ESP (in. W.C.) 040V14--10 35 29.50 14.20 39,000 25,000 96.0% 95.0% YES 800 560 0.10 1030 1/2 040V17--12 35 29.50 17.50 39,000 25,000 96.0% 95.0% YES 850 625 0.10 1105 1/2 060V14--12 35 29.50 14.20 58,000 38,000 95.0% 95.0% YES 1110 770 0.12 1115 1/2 060V17--14 35 29.50 17.50 58,000 38,000 96.3% 95.0% YES 1135 860 0.12 1475 3/4 080V17-16 35 29.50 17.50 78,000 50,000 96.2% 95.0% YES 1450 1130 0.15 1655 3/4 080V21-20 35 29.50 21.00 78,000 51,000 96.5% 95.0% YES 1555 1200 0.15 2005 1 10OV21-20 35 29.50 21.00 97,000 63,000 96.1% 95.0% YES 1865 1435 0.20 2005 1 10OV21-22 35 29.50 21.00 97,000 63,000 96.1% 95.0% YES 1765 1350 0.20 2275 1 120V24-22 35 29.50 24.00 117,000 76,000 96.5% 95.0% YES 2120 1625 0.20 2190 1 *. Capacity in accordance with DOE test procedures. Ratings are position dependent. See raring plate. ESP =External Static Prsessure FEATURES AND BENEFITS Comfort Heat Technology® - This feature with Adaptive Control is a proprietary function that promotes homeowner comfort through two stages of heating. This furnace offers a patented algorithm that continually monitors and adjusts furnace operation by looking at both current and past conditions to determine the most effective stage of heating and the amount of time to run each stage, every cycle. SmartEvapTM Technology - When paired with a compatible thermostat, this dehumidification feature overrides the cooling blower off -delay when there is a call for dehumidification. By deactivating the blower off -delay, SmartEvap technology prevents condensate that remains on the coil after a dehumidification cycle from re -humidifying throughout the home. This results in reduced humidity and a more comfortable indoor environment for the homeowner. Unlike competitive systems, SmartEvap technology only overrides the cooling blower off delay when humidity control is needed. Once humidity is back in control, SmartEvap re -enables the energy -saving cooling blower off -delay. ComfortFanTM Technology - Sometimes the constant fan setting on a standard furnace system can actually reduce homeowner comfort by providing too much or too little air! ComfortFan technology improves comfort all year long by allowing the homeowner to select the continuous fan speed of their choice using a compatible thermostat. HYBRID HEAT® Dual Fuel - This system can provide more control over your monthly energy bills by automatically selecting the most economical method of heating. With HYBRID HEAT® Dual Fuel, our system automatically switches between the gas furnace and the electric heat pump as outside temperatures change to maintain greater efficiency and comfort than with any traditional single -source heating system. The heat pump also delivers high -efficiency cooling in the summer. Power Heaem Robust Igniter - Carrier's unique SiN igniter is not only physically robust is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators. This unique feature further enhances the gas furnace reliability and continues Carrier's tradition of technology leadership and innovation in providing a reliable and durable product. ECM Motors - Our variable -speed, constant torque ECM (Electronically Commutated Motor) optimizes comfort levels in the home year round; features such as passive/active dehumidification, ramping profiles, and quiet operation. It can provide cooling match enhancements to increase the effective SEER of select Carrier air conditioner or heat pump systems. This motor does not report back RPM and static pressure to the furnace control. Reliable Heat Exchanger Design - The aluminized steel, clam shell primary heat exchanger features a crimped, no -weld seam to create an efficient, robust design for this essential component. The condensing heat exchanger, a stainless steel fm and tube design, is positioned in the furnace to extract additional heat. Stainless steel coupling box componentry between heat exchangers has exceptional corrosion resistance in both natural gas and propane applications. Optional Media Filter Cabinet - Enhanced indoor air quality in the home is made easier with our media filter cabinet (available as an accessory). When installed as a part of the system, this cabinet allows for easy and convenient addition of a Carrierhigh efficiency air filter. 4-Way Multipoise Design - One model for all applications - there is no need to stock special downflow or horizontal models when one unit will do it all. Direct or Single -pipe Venting, or Optional Ventilated Combustion Air - This furnace can be installed as a 2-pipe (Direct Vent) furnace, in an optional ventilated combustion air application, or in single -pipe, non -direct vent applications. This provides added flexibility to meet diverse installation needs. Sealed Combustion System - This furnace brings in combustion air from outside the furnace, which results in especially quiet operation. By sealing the entire combustion vestibule, the entire furnace can be made quieter, not just the burners. Insulated Casing - Foil -faced insulation in heat exchanger section of the casing minimizes heat loss. The acoustical insulation in the blower compartment reduces air and motor noise for quiet operation. Monoport Burners - The burners are specially designed and finely tuned for smooth, quiet combustion and economical operation. Bottom Closure - Factory -installed for side return; easily removable for bottom return. The multi -use bottom closure can also serve for roll -out protection in horizontal applications, and act as the bottom closure for the optional return air base accessory. Certifications - This furnace is CSA (AGA and CGA) design certified for use with natural and propane gases. The furnace is factory -shipped for use with natural gas. A CSA listed gas conversion kit is required to convert furnace for use with propane gas. The efficiency is AHRI efficiency rating certified. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 59TP613: Product Data DIMENSIONAL DRAWING E E c > .—m`£Ex Qac„r Go"i_m �wLcn d;o E E w E E N '„ 00t; c o = E 8 c E N o c m;� H 1 =- cc Z W C6 A B C D SHIP WT. FURNACE SIZE CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE LB (KG) 040V14--10 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 123 (55.8) 060V14--12 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 132 (59.9) 060V17--14 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 146 (66.2) 080V17--16 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 150 (68) 080V21--20 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 161 (73) 10OV21--20 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 170 (77.1) 10OV21--22 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 170 (77.1) 120V24--22 24-1/2 (622) 22-7/8 (581) 23 (584) 12-1/4 (311) 189 (85.6) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 59TP6B: Product Data MODEL NUMBER NOMENCLATURE 6 1,2 3 4 5 Major 7, 8, 9 Gas Furnace Heating Stages Tier Min. AFUE/NOx Series Heating Input 59 M N 7 B 060 13 10 11,12 Voltage 14 15,16 Motor Type Width (1-phase) Minor Series Airflow E 17 1 1 16 I 08 = 800 CFM 10 = 1000 CFM 12 =1200 CFM 58 = 80% C = Comm. Variable- 14 = 1400 CFM Non -Condensing Speed 16 = 1600 CFM 59 = 90%+ B = Base 0 = Std. NOx 80% Constant Airflow 1 20 = 2000 CFM Condensing C = Comfort 1 = 80% Low Nox (VCA) ECM 2 22 = 2200 CFM E = Export --- E= Fixed -Speeds 3 M = Modulating N = Infinity 2 = 92% Constant Torque 14 - 14.2" 1 = 11 OV/60Hz S = Single Stage P = Performance 5 = 95 % 026 = 26,000 BTU (FCT) ECM 17 - 17.5" 2 = 230V/5OHz T = Two Stage U = Ultra Low 6 = 96% A 040 = 40.000 BTU V = Variable -Speed 21 - 21.0" Nox 7 = 97% B 060 = 60,000 BTU Constant Torque 24 - 24.5" 8=98% C --- CT ECM --- 155 = 155.000 BTU A200524 FURNACE COMPONENTS F AME SENSOR— MANUALRESET ROLLOUT SWITCH GAS VALVE — OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE). ELECTRICAL JUNCTION BOX (IF REQUIRED, — LOCATION MAY VARY) BLOWER DOOR — SAFETY SWITCH FURNACE CONTROL BOARD RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR) 12 HOT SURFACE IGNITER GAS BURNER MANUAL RESET ROLLOUT SWITCH C MA IN LIMIT SWITCH (BEHIND GAS VALVE) 44hfK"' � "JBLOWER �p AND MOTOR A190145 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4 59TP6B: Product Data SPECIFICATIONS The furnace should be sized to provide 100 percent of the design heating load requirement plus any margin that occurs because of furnace model size capacity increments. None of the furnace model sizes can be used if the heating load is 20,000 BTU or lower. Use Air Conditioning Contractors of America (Manual J and S); American Society of Heating, Refrigerating, and Air -Conditioning Engineers; or other approved engineering method to calculate heating load estimates and select the furnace. Excessive oversizing of the furnace may cause the furnace and/or vent to fail prematurely, customer discomfort and/or vent freezing. Failure to follow these guidelines is considered faulty installation and/or misapplication of the furnace; and resulting failure, damage, or repairs may impact warranty coverage. If -------- 1 Heating Capacity and Efficiency 040V14--10 040V17--12 060V14--12 060V17--14 080V17--16 080V21--20 100V21--20 100V21--22 120V24--22 High (BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 Input Heat Low Heat (BTUH) 26,000 26,000 39,000 39,000 52,000 52,000 65,000 65,000 78,000 High (BTUH) 39,000 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 Output Heat Low Heat (BTUH) 25,000 25,000 38,000 38,000 50,000 51,000 63,000 63,000 76,000 High Heat 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 Certified Temperature (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) Rise Range IF (°C) Low Heat 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) Airflow Capacity and Blower Data Rated External Static Heating 0.10 0.10 0.12 0.12 0.15 0.15 0.20 0.20 0.20 Pressure (in. w.c.) Cooling 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 Airflow Delivery High Heat 800 850 1110 1135 1450 1555 1865 1765 2120 Rated ESP Low Heat 560 625 770 860 1130 1200 1435 1350 1625 @ (CFM) Cooling 1030 1105 1115 1475 1655 2005 2005 2275 2190 Cooling Capacity (tons) 400 CFM/ton 2 2.5 2.5 3.5 4 5 5 5.5 5 @ 400, 350 CFM/ton 350 CFM/ton 2.5 3 3 4 4.5 5.5 5.5 6 1 6 Direct -Drive Motor Type Electronically Commutated Motor (ECM) Direct -Drive Motor HP 1/2 1/2 1/2 3/4 3/4 1 1 1 1 1 1 Motor Full Load Amps Default / Low 6.3 6.5 6.3 1600-2000 10.1 9.2 13.9/10.4 13.9/10.4 10.4 11.7 Amp Kit{ RPM Range 600-2000 400-1200 400-1200 400-1200 1 400-1200 400-1200 400-1300 400-1200 Speed Selections Variable (PWM) Blower Wheel Diax in. 11x7 11x8 11x7 11x8 11x8 11x10 11x10 11x10 11 x 11 Width Air Filtration System Field Supplied Filter Filter Used for Certified Watt Data 325531-40' Electrical Data Input Volts -Hertz -Phase 115-60-1 Voltage Operating Voltage Min -Max 104-127 Range Maximum InputAmps Amps 7.0 7.2 7.1 10.9 10.0 14.7/11.3 14.7/11.3 12.6 12.6 Default / Low Amp Kit{ Unit Ampacity Default / Amps 9.7 9.8 9.7 14.6 13.4 19.3/14.9 19.4/15.0 16.7 16.7 Low Amp Kit{ Minimum Wire Size AWG 14 14 14 14 14 12/14 12/14 12 12 Default / Low Amp Kit{ Maximum Wire Length Feet 38 37 1 38 25 27 29/24 29/24 34 34 @ Minimum Wire Size (M) (11.7) (11.5) (11.7) (7.7) (8.4) (9.0/7.5) (9.0/7.5) (10.5) (10.5) Default / Low Amp Kit{ Maximum Fuse/Ckt Bkr (Time -Delay Type Amps 15 15 15 15 15 20/15 20/15 20 20 Recommended)Default / Low Amp Kit( Transformer Capacity (24vac output) VA External Control Power Heating 24.3 VA Available Cooling 34.6 VA Controls Gas Connection Size 1/2" - NPT Burners (Monoport) 2 1 2 3 3 4 4 1 5 1 5 6 Gas Valve (Redundant) FManufacturer White Rodgers Minimum Inlet Gas pressure (in. we) 4.50 Maximum Inlet Gas pressure (in. we) 13.60 Manufactured (Mobile) Home Kit not approved for MH use Ignition Device Silicon Nitride Heating Blower Control (Heating Adjustable: 90, 120, 150, 180 seconds Off -Delay) Cooling Blower Control (Time Delay 90 seconds Relay) Communication System None Thermostat Connections R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM Accessory Connections EAC (115vac); HUM (24vac); 1-stg. AC (via YN2) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 59TP613: Product Data ACCESSORIES DESCRIPTION PART NUMBER 040V14--10 040V17--12 060V14--12 060V17--14 Vent Kit - Through the Cabinet KGADC0101 BVC X X X X See Venting Tables Vent Terminal - Concentric - 2" (51 mm) KGAVT0701 CVT Vent Terminal - Concentric - 3" (76 mm) KGAVT0801 CVT Vent Terminal Bracket - 2" (51 mm) KGAVTO101 BRA Vent Terminal Bracket - 3" (76 mm) KGAVT0201 BRA Vent Kit - Rubber Coupling KGAAC0101 RVC Freeze Protect Kit - Condensate Drain Line Tape KGAHT0101CFP X X X X Freeze Protect Kit - Condensate Trap with Heat Pad KGAHT0201 CFP X X X X CPVC to PVC Drain Adapters - 1/2" CPVC to 3/4" PVC KGAAD0110PVC X X X X Horizontal Trap Grommet - Direct Vent KGACK0101 HCK All 2-Pipe Horizontal Condensate Neutralizer Kit P908-0001 X X X X External Trap Kit KGAET0201 ETK X X X X Downflow Furnace Base Kit for Combustible Floors KGASB0201ALL X X X X Coil Adapter Kits - No Offset KGADA0101ALL X X X X Coil Adapter Kits - Single Offset KGADA0201ALL X X X X Coil Adapter Kits - Double Offset KGADA0301ALL X X X X Return Air Base (Upflow Applications) 14.0-in. wide KGARP0301614 X - X - Return Air Base (Upflow Applications) 17.5-in. wide KGARP0301 B17 X - X IAQ Device Duct Adapters 20.0-in. IAQ to 16 in. Side Return KGAAD0101 MEC 20"x25" IAQ Devices IAQ Device Duct Adapters 24.0-in. IAQ to 16 in. Side Return KGAAD0201 MEC 24"x25 IAQ Devices Gas Conversion Kit - Nat to LP AGAGC9NPS01 B X X X X Gas Conversion Kit - LP to Nat AGAGC9PNS01 B X X X X Gas Valve Tower Port Adapter Kit 92-1003 X X X X Twinning Kit AGATWNPME01B - - - X External Bottom Return Filter Rack FHG1425-2 X - X - FHG1625-2 - X X Unframed Filter 3/4-in. (19 mm)` 325531-402 X X X X *. Purchased through Replacement Components X Used with the model furnace DESCRIPTION PART NUMBER 080V17--16 I 080V21--20 I 100V21--20 I 100V21--22 120V24--22 Vent Kit - Through the Cabinet KGADC0101 BVC X I X X X X See Venting Tables Vent Terminal - Concentric - 2" (51 mm) KGAVT0701 CVT Vent Terminal - Concentric - 3" (76 mm) KGAVT0801 CVT Vent Terminal Bracket - 2" (51 mm) KGAVTO101 BRA Vent Terminal Bracket - 3" (76 mm) KGAVT0201 BRA Vent Kit - Rubber Coupling KGAAC0101 RVC Freeze Protect Kit - Condensate Drain Line Tape KGAHT0101 CFP X X X X X Freeze Protect Kit - Condensate Trap with Heat Pad KGAHT0201 CFP X X X X X CPVC to PVC Drain Adapters - 1/2" CPVC to 3/4" PVC KGAAD0110PVC X X X X X Horizontal Trap Grommet - Direct Vent KGACK0101 HCK All 2-Pipe Horizontal Condensate Neutralizer Kit P908-0001 X X X X X External Trap Kit KGAET0201 ETK X X X X X Downflow Furnace Base Kit for Combustible Floors KGASB0201ALL X X X X X Coil Adapter Kits - No Offset KGADA0101ALL X X X X X Coil Adapter Kits - Single Offset KGADA0201ALL X X X X X Coil Adapter Kits - Double Offset KGADA0301ALL X X X X X Return Air Base (Upflow Applications) 17.5-in. wide KGARP0301B17 X - - - Return Air Base (Upflow Applications) 21.0-in. wide KGARP0301B21 - X X X - Return Air Base (Upflow Applications) 24.5-in. wide KGARP0301B24 - - - X IAQ Device Duct Adapters 20.0-in. IAQ to 16 in. Side Return KGAAD0101 MEC 20"x25" IAQ Devices IAQ Device Duct Adapters 24.0-in. IAQ to 16 in. Side Return KGAAD0201 MEC 24"x25 IAQ Devices Gas Conversion Kit - Nat to LP AGAGC9NPS01 B X X X X X Gas Conversion Kit - LP to Nat AGAGC9PNS01 B X X X X X Gas Valve Tower Port Adapter Kit 92-1003 X X X X X Twinning Kit AGATWNPME01B X X X X X External Bottom Return Filter Rack* Unframed Filter 3/4-in. (19 mm)* FHG1625-2 X - - - - FHG2025-2 - X X X - FHG2424-2 - - - X 325531-402 X - - - 325531-403 - X X X - 325531-404 - - - X Lower Amp Kit KGAPCO101 ECM - X X X - *. Purchased through Replacement Components X Used with the model furnace Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 59TP6B: Product Data ACCESSORIES (CONTINUED) DESCRIPTION Gas Orifice Kit - #42 (Nat Gas) LH32DB207 See Installation Instructions for model, altitude, and heat value usages. Gas Orifice Kit - #43 (Nat Gas) LH32DB202 Gas Orifice Kit - #44 (Nat Gas) LH32DB200 Gas Orifice Kit - #45 (Nat Gas) LH32DB205 Gas Orifice Kit - #46 (Nat Gas) LH32DB208 Gas Orifice Kit - #47 (Nat Gas) LH32DBO78 Gas Orifice Kit - #48 (Nat Gas) LH32DBO76 Gas Orifice Kit - #54 (LP) LH32DB203 Gas Orifice Kit - #55 (LP) LH32DB201 Gas Orifice Kit - #56 (LP) LH32DB206 Gas Orifice Kit 1.25mm (LP) LH32DB209 Gas Orifice Kit - 1.30mm (LP) LH32DB210 DESCRIPTION ACCESSORY HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL Carrier has a wide variety of thermostats for your system, please visit www.Carrier.com to see all thermostat and IAQ products. DESCRIPTION ACCESSORY 14" 17" 21" 24" Carrier Carbon Monoxide Alarm (10 pack) COALMCCNRB02-A10 X X X X Carrier Infinity Air Purifier- 16x25 (407x635 mm) DGAPAXX1625 X X Carrier Infinity Air Purifier - 20x25 (508x635 mm) DGAPAXX2025 - X X Carrier Infinity Air Purifier Repl. Filter- 16x25 (407x635 mm) PGAPXCAR1625A02 X X Carrier Infinity Air Purifier Repl. Filter- 20x25 (508x635 mm) PGAPXCAR2025A02 - X X Cartridge Media Filter - 16" (407 mm) (MERV 11) FILXXCAR0116 X X - Cartridge Media Filter- 16" (407 mm) (MERV 8) FILXXCAR0016 X X - Cartridge Media Filter- 20" (508 mm) (MERV 8) FILXXCAR0020 X - Cartridge Media Filter- 20" (508 mm) (MERV11) FILXXCAR0120 X Cartridge Media Filter- 24" (610 mm) (MERV 8) FILXXCAR0024 X Cartridge Media Filter - 24" (610 mm) (MERV11) FILXXCAR0124 X EZ Flex Cabinet Side or Bottom - 16" EZXCAB--0016 X X EZ Flex Cabinet Side or Bottom - 20" EZXCAB--0020 X X EZ Flex Replacement Filters 16" MERV 10 EXPXXFIL0016 X X - EZ Flex Replacement Filters 16" MERV 13 EXPXXFIL0316 X X - EZ Flex Replacement Filters 20" MERV 10 EXPXXFIL0020 X EZ Flex Replacement Filters 20" MERV 13 EXPXXFIL0320 X EZ Flex Replacement Filters 24" MERV 10 EXPXXFIL0024 X EZ Flex Replacement Filters 24" MERV 13 EXPXXFIL0324 X EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 10) EXPXXUNVO016 X X EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 13) EXPXXUNV0316 X X EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 10) EXPXXUNVO020 - X EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 13) EXPXXUNV0320 X EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 10) EXPXXUNVO024 X EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 13) EXPXXUNV0324 X Media Filter Cabinet - 20" FILCABXL0020 X Media Filter Cabinet - 24" FILCABXL0024 X Media Filter Cabinet - 16" FILCABXL0016 X X Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 59TP6B: Product Data /_1IA174AU/4:419 Air Delivery - CFM (With Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See notes 1 and 2.) Unit Size: 040V14--10 Clg/CF Switch settings External Static Pressure (ESP) CIg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1125 1105 1080 1055 1030 1005 915 955 930 905 OFF OFF ON 605 565 525 485 445 See Note 4 OFF ON OFF 760 730 695 655 625 590 555 525 490 455 OFF ON ON 950 925 900 870 840 810 785 760 730 705 Cooling ON OFF OFF 1125 1105 1080 1055 1030 1005 975 955 930 905 (SW2-8,7,6) ON OFF ON 1130 1105 1080 1055 1030 1005 980 955 930 905 ON ON OFF 1130 1105 1080 1055 1030 1005 980 955 930 905 ON ON ON 1130 1105 1080 1055 1030 1005 980 955 930 905 Maximum Clg Airflow 1130 1105 1080 1055 1030 1005 980 955 930 905 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 605 565 525 485 445 See Note 4 OFF OFF ON 605 565 525 485 445 See Note 4 OFF ON FF 760 730 695 655 625 590 555 525 490 455 OFF ON ON 950 925 900 870 840 810 785 760 730 705 Low -Cooling (SW2-5,4,3) ON OFF OFF 1125 1105 1080 1055 1030 1005 975 955 930 905 ON OFF ON 1130 1105 1080 1055 1030 1005 980 955 930 905 ON ON OFF 1130 1105 1080 1055 1030 1005 980 955 930 905 ON ON ON 1130 1105 1080 1055 1030 1005 980 955 930 905 Cont. Fan Default: OFF OFF OFF 385 335 See Note 4 OFF OFF ON 245 180 See Note 4 OFF ON OFF 310 245 See Note 4 OFF ON ON 385 335 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 385 335 See Note 4 ON OFF ON 385 335 See Note 4 ON ON OFF 385 335 See Note 4 ON ON ON 385 335 See Note 4 Heating (SW1) High Heat Airflow 800 770 730 700 665 635 605 570 540 510 Low Heat Airflow3 560 520 470 425 390 See Note 4 Unit Size: 040V17--12 Clg/CF Switch settings External Static Pressure (ESP) CIg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Gig Default: OFF OFF OFF 1240 1210 1180 1145 1105 1060 1005 950 895 835 OFF OFF ON 585 540 490 445 400 360 315 265 210 155 OFF ON OFF 780 740 695 655 620 580 545 510 480 445 OFF ON ON 975 945 910 870 835 805 775 740 710 680 Cooling ON OFF OFF 1170 1140 1115 1085 1050 1020 985 945 890 835 (SW2-8,7,6) ON OFF ON 1240 1210 1180 1145 1105 1060 1005 950 895 835 ON ON OFF 1240 1210 1180 1145 1105 1060 1005 950 895 835 ON ON ON 1240 1210 1180 1145 1105 1060 1005 950 895 835 Maximum Clg Airflow2 1240 1210 1180 1145 1105 1060 1005 950 895 835 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 585 540 490 445 400 See Note 4 OFF OFF ON 585 540 490 445 400 See Note 4 OFF ON OFF 780 740 695 655 620 580 545 510 480 445 OFF ON ON 975 945 910 870 835 805 775 740 710 680 Low -Cooling (SW2-5,4,3) ON OFF OFF 1170 1140 1115 1085 1050 1020 985 945 890 835 ON OFF ON 1240 1210 1180 1145 1105 1060 1005 950 895 835 ON ON OFF 1240 1210 1180 1145 1105 1060 1005 950 895 835 ON ON ON 1240 1210 1180 1145 1105 1060 1005 950 895 835 Cont. Fan Default: OFF OFF OFF 585 540 490 445 400 See Note 4 OFF OFF ON 305 235 See Note 4 OFF ON OFF 470 410 350 See Note 4 OFF ON ON 585 540 490 445 400 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 585 540 490 445 400 See Note 4 ON OFF ON 585 540 490 445 400 See Note 4 ON ON OFF 585 540 490 445 400 See Note 4 ON ON ON 585 540 490 445 400 See Note 4 Heating (SW1) High Heat Airflow3 850 810 770 730 700 660 630 595 560 530 Low Heat Airflow 625 1 580 535 490 445 405 365 320 270 220 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 59TP6B: Product Data Air Delivery - CFM (With Filter) (Continued) (SW1-5 and SW2-2 set to OFF, except as indicated. See notes 1 and 2.) Unit Size: 060V14--12 Clg/CF Switch settings External Static Pressure (ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1180 1150 1130 1100 1075 1045 1020 995 965 1 935 OFF OFF ON 625 585 540 495 445 See Note 4 OFF ON OFF 820 785 745 710 670 635 595 560 525 490 OFF ON ON 1000 970 935 905 875 845 815 785 755 725 Cooling ON OFF OFF 1180 1150 1130 1100 1075 1045 1020 995 965 935 (SW2-8,7,6) ON OFF ON 1220 1195 1170 1140 1115 1090 1065 1035 1010 985 ON ON OFF 1220 1195 1170 1140 1115 1090 1065 1035 1010 985 ON ON ON 1220 1195 1170 1140 1115 1090 1065 1035 1010 985 Maximum Clg Airflow2 1220 1195 1170 1140 1115 1090 1065 1035 1010 985 CIF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 625 585 540 495 445 See Note 4 OFF OFF ON 625 585 540 495 445 See Note 4 OFF ON OFF 820 785 745 710 670 635 595 560 525 490 OFF ON ON 1000 970 935 905 875 845 815 785 755 725 Low -Cooling (SW2-5,4,3) ON OFF OFF 1180 1150 1130 1100 1075 1045 1020 995 965 935 ON OFF ON 1220 1195 1170 1140 1115 1090 1065 1035 1010 985 ON ON OFF 1220 1195 1170 1140 1115 1090 1065 1035 1010 985 ON ON ON 1220 1195 1170 1140 1115 1090 1065 1035 1010 985 Cont. Fan Default: OFF OFF OFF 375 315 See Note 4 OFF OFF ON 200 125 See Note 4 FF ON OFF 285 215 See Note 4 OFF ON ON 375 315 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 375 315 See Note 4 ON OFF ON 375 315 See Note 4 N ON OFF 375 315 See Note 4 ON ON ON 375 315 See Note 4 Heating (SW1) High HeatAirflow3 1115 1090 1060 1035 1010 980 955 930 905 875 Low HeatAirflow3 780 740 695 655 615 575 530 490 450 405 Unit Size: O60V17--14 Clg/CF Switch settings External Static Pressure (ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 OFF OFF ON 725 600 435 280 210 See Note 4 OFF ON OFF 780 725 660 615 540 See Note 4 OFF ON ON 975 925 875 835 785 750 690 655 610 570 Cooling ON OFF OFF 1160 1120 1090 1045 1010 970 920 885 840 800 (SW2-8,7,6) ON OFF ON 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 ON ON OFF 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 ON ON ON 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 Maximum Clg Airflow2 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 CIF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 725 600 435 280 210 bee Note OFF OFF ON 725 600 435 280 210 See Note 4 OFF ON FF 780 725 660 615 540 See Note 4 OFF ON ON 975 925 875 835 785 750 690 655 610 570 Low -Cooling (SW2-5,4,3) ON OFF FF 1160 1120 1090 1045 1010 970 920 885 840 800 ON OFF ON 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 ON ON FF 1 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 ON ON ON 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 Cont. Fan Default: OFF OFF OFF 725 600 435 280 210 See Note 4 OFF OFF ON 725 600 435 280 210 See Note 4 OFF ON OFF 780 725 660 615 540 See Note 4 OFF ON ON 975 925 875 835 785 750 690 655 610 570 Continuous Fan (SW2-5,4,3) ON OFF OFF 975 925 875 835 785 750 690 655 610 570 ON OFF ON 975 925 875 835 785 750 690 655 610 570 ON ON OFF 975 925 875 835 785 750 690 655 610 570 ON ON ON 975 925 875 835 785 750 690 655 610 570 Heating (SW1) High HeatAirflow3 1145 1105 1075 1030 995 955 905 870 825 785 Low Heat Airflow3 870 820 760 720 655 620 560 525 470 435 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 59TP6B: Product Data Air Delivery - CFM (With Filter) (Continued) SW1-5 and SW2-2 set to OFF, except as indicated. See notes 1 and 2. Unit Size: 080V17--16 Clg/CF Switch settings External Static Pressure (ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1595 1560 1530 1500 1470 1440 1405 1370 j 1340 1290 OFF OFF ON 625 555 495 425 360 300 See Note 4 OFF ON OFF 810 755 700 645 595 540 480 425 380 330 OFF ON ON 1040 995 950 900 860 815 770 725 680 630 Cooling ON OFF OFF 1215 1175 1135 1095 1055 1015 975 935 900 860 (SW2-8,7,6) ON OFF ON 1390 1355 1320 1285 1245 1210 1175 1140 1105 1070 ON ON OFF 1595 1560 1530 1500 1470 1440 1405 1370 1340 1290 ON ON ON 1790 1760 1735 1700 1655 1610 1570 1485 1395 1295 Maximum Clg Airflow2 1790 1760 1735 1700 1655 1610 1570 1485 1395 1295 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 625 555 495 425 360 300 See Note 4 OFF OFF ON 625 555 495 425 360 300 See Note 4 OFF ON OFF 810 755 700 645 595 540 480 425 380 330 OFF ON ON 1040 995 950 900 860 815 770 725 680 630 Low -Cooling (SW2-5,4,3) ON OFF OFF 1215 1175 1135 1095 1055 1015 975 935 900 860 ON OFF ON 1390 1355 1320 1285 1245 1210 1175 1140 1105 1070 ON ON OFF 1595 1560 1530 1500 1470 1440 1405 1370 1340 1290 ON ON ON 1190 1760 1735 1700 1655 1610 1570 1485 1395 1295 Cont. Fan Default: OFF OFF OFF 625 555 495 425 360 300 See Note 4 OFF OFF ON 465 390 300 See Note 4 OFF ON OFF 625 555 495 425 360 300 See Note 4 OFF ON ON 690 630 570 510 445 385 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 690 630 570 510 445 385 See Note 4 ON OFF ON 690 630 570 510 445 385 See Note 4 ON ON OFF 690 630 570 510 445 385 See Note 4 ON ON ON 690 630 570 510 445 385 See Note 4 Heating (SW1) High HeatAirflow3 1470 1435 1400 1365 1330 1295 1260 1225 1190 1155 Low HeatAirflow3 1150 1110 1070 1030 990 950 910 870 830 790 Unit Size: 080V21--20 Clg/CF Switch settings External Static Pressure (ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1905 1870 1825 1785 1750 1700 1665 1625 1560 1460 OFF OFF ON 950 770 620 515 440 365 See Note 4 OFF ON OFF 1015 935 880 825 765 690 625 580 See Note 4 OFF ON ON 1155 1105 1040 990 920 875 815 755 710 645 Cooling ON OFF OFF 1335 1290 1245 1190 1145 1085 1040 990 930 890 (SW2-8,7,6) ON OFF ON 1520 1485 1435 1390 1340 1300 1255 1200 1160 1115 ON ON OFF 1905 1870 1825 1785 1750 1700 1665 1625 1560 1460 ON ON ON 2290 223U 2160 2085 2005 1915 1820 1730 1640 1525 Maximum Clg Airflow2 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525 CF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 950 770 620 515 440 365 See Note 4 OFF OFF ON 645 540 435 See Note 4 OFF ON OFF 950 770 620 515 440 365 See Note 4 OFF ON ON 1015 935 880 825 765 690 625 580 See Note 4 Low -Cooling (SW2-5,4,3) ON OFF OFF 1155 1105 1040 990 920 875 815 755 710 645 ON OFF ON 1335 1290 1245 1190 1145 1085 1040 990 930 890 ON ON OFF 1520 1485 1435 1390 1340 1300 1255 1200 1160 1115 ON ON ON 1905 1870 1825 1785 1750 1700 1665 1625 1560 1460 Cont. Fan Default: OFF OFF OFF 950 770 620 515 440 365 See Note 4 OFF OFF ON 645 540 435 See Note 4 OFF ON OFF 950 770 620 515 440 365 See Note 4 OFF ON ON 1015 935 880 825 765 690 625 580 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 1155 1105 1040 990 920 875 815 755 710 645 ON OFF ON 1335 1290 1245 1190 1145 1085 1040 990 930 890 ON ON OFF 1520 1485 1435 1390 1340 1300 1255 1200 1160 1115 ON ON ON 1520 1485 1435 1390 1340 1300 1255 1200 1160 1115 Heating (SW1) High HeatAirflow3 1575 1535 1485 1445 1400 1350 1310 1260 1215 1170 Low HeatAirflow3 1230 1170 1125 1065 1015 955 900 855 795 755 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 59TP6B: Product Data Air Delivery - CFM (With Filter) (Continued) (SW1-5 and SW2-2 set to OFF, except as indicated. See notes 1 and 2.) Unit Size: 100V21--20 Clg/CF Switch settings External Static Pressure (ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1890 1845 1800 1755 1700 1655 1610 1 1560 1510 1460 OFF OFF ON 1015 825 630 485 405 325 See Note 4 OFF ON OFF 1080 895 815 740 690 615 555 475 See Note 4 OFF ON ON 1155 1080 1020 940 890 825 785 710 660 590 Cooling ON OFF OFF 1310 1260 1195 1140 1075 1025 970 925 875 810 (SW2-8,7,6) ON OFF ON 1520 1475 1425 1365 1315 1255 1210 1155 1110 1055 ON ON OFF 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460 ON ON ON 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525 Maximum Clg Airflow 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525 CIF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 1015 825 630 485 405 325 See Note 4 OFF OFF ON 745 640 535 See Note 4 OFF ON OFF 1015 825 630 485 405 325 See Note 4 OFF ON ON 1080 895 815 740 690 615 555 475 See Note 4 Low -Cooling (SW2-5,4,3) ON OFF OFF 1155 1080 1020 940 890 825 785 710 660 590 ON OFF ON 1310 1260 1195 1140 1075 1025 970 925 875 810 ON ON OFF 1520 1475 1 1425 1365 1315 1255 1210 1155 1110 1055 ON ON ON 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460 Cont. Fan Default: OFF OFF OFF 1015 825 630 485 405 325 See Note 4 OFF OFF ON 745 640 535 See Note 4 OFF ON OFF 1015 825 630 485 405 325 See Note 4 OFF ON ON 1080 895 815 740 690 615 555 475 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 1155 1080 1020 940 890 825 785 710 660 590 ON OFF ON 1155 1080 1020 940 890 825 785 710 660 590 ON ON OFF 1155 1080 1020 1 940 890 825 785 710 660 590 ON ON ON 1155 1080 1020 940 890 825 785 710 660 590 Heating (SW1) High Heat Airflow 3 1905 1865 1825 1775 1730 1685 1640 1590 1545 1490 Low Heat Airflow3 1480 1435 1375 1330 1265 1215 1160 1115 1060 1005 Unit Size: 100V21--22 Clg/CF Switch settings External Static Pressure (ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1990 1945 1905 1865 1820 1780 1 1735 1695 1650 1600 OFF OFF ON 885 800 700 See Note 4 OFF ON OFF 1105 1035 955 870 See Note 4 OFF ON ON 1255 1190 1125 1055 975 See Note 4 Cooling ON OFF OFF 1445 1390 1330 1270 1210 1140 1075 See Note 4 (SW2-8,7,6) ON OFF ON 1655 1610 1560 1505 1455 1400 1345 1285 See Note 4 ON ON OFF 1990 1945 1905 1865 1820 1780 1735 1695 1650 1600 ON ON ON 2135 2095 2060 2025 1985 1945 1905 1865 1820 1780 Maximum Clg Airflow2 2440 2405 2365 2320 2275 2230 2180 2135 2080 2030 CIF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 885 800 700 See Note 4 OFF OFF ON 740 630 See Note 4 OFF ON OFF 885 800 700 See Note 4 OFF ON ON 1105 1035 955 870 See Note 4 Low -Cooling (SW2-5,4,3) ON OFF OFF 1255 1190 1125 1055 975 See Note 4 ON OFF ON 1445 1390 1330 1270 1210 1140 1075 See Note 4 ON ON OFF 1655 1610 1560 1505 1455 1400 1345 1285 See Note 4 ON ON ON 1990 1 1945 1905 1865 1820 1780 1735 1695 1650 1 1600 ir Cont. Fan Default: OFF OFF OFF 885 800 700 See Note 4 OFF OFF ON 740 630 See Note 4 OFF ON OFF 885 800 700 See Note 4 OFF ON ON 1105 1035 955 870 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 1255 1190 1125 1055 975 See Note 4 ON OFF ON 1445 1390 1330 1270 1210 1140 1075 See Note 4 ON ON OFF 1655 1610 1560 1505 1455 1400 1345 1285 See Note 4 ON ON ON 1655 1610 1560 1505 1455 1400 1345 1285 See Note 4 Heating (SW1) High Heat Airflow 3 1810 1765 1720 1675 1625 1575 1525 1475 1425 1 1375 Low Heat Airflow' 1405 1350 1290 1225 1160 1100 See Note 4 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 59TP6B: Product Data Air Delivery - CFM (With Filter) (Continued) (SW1-5 and SW2-2 set to OFF, except as indicated. See notes 1 and 2.) Unit Size: 120V24--22 Clg/CF Switch settings External Static Pressure (ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 2060 2015 1975 1930 1885 1840 1190 1750 1705 1630 OFF OFF ON 865 775 690 595 505 425 See Note 4 OFF ON OFF 1080 1005 935 860 785 705 625 555 490 425 OFF ON ON 1285 1220 1150 1085 1020 960 895 820 750 690 Cooling ON OFF OFF 1465 1410 1350 1285 1230 1175 1115 1060 1000 935 (SW2-8,7,6) ON OFF ON 1685 1635 1585 1530 1475 1420 1375 1325 1270 1225 ON ON OFF 2060 2015 1975 1930 1885 1840 1790 1750 1705 1630 ON ON ON 2265 2225 2180 2145 2100 2060 2010 1895 1770 1645 Maximum Clg Airflow 2320 2310 2270 2230 2190 2135 2020 1895 1770 1645 CIF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 865 775 690 595 505 425 See Note 4 OFF OFF ON 585 470 See Note 4 OFF ON OFF 865 775 690 595 505 425 See Note 4 OFF ON ON 1080 1005 935 860 785 705 625 555 490 425 Low -Cooling (SW2-5,4,3) ON OFF OFF 1285 1220 1150 1085 1020 960 895 820 750 690 ON OFF ON 1465 1410 1350 1285 1230 1175 1115 1060 1000 935 ON ON OFF 1685 1635 1585 1530 1475 1420 1375 1325 1270 1225 ON ON ON 2060 2015 1975 1930 1885 1840 1790 1750 1705 1630 Cont. Fan Default: OFF OFF OFF 865 775 690 595 505 425 See Note 4 OFF OFF ON 585 470 See Note 4 OFF ON OFF 730 630 See Note 4 OFF ON ON 865 775 690 595 505 425 See Note 4 Continuous Fan (SW2-5,4,3) ON OFF OFF 865 775 690 595 505 425 See Note 4 ON OFF ON 865 775 690 595 505 425 See Note 4 ON ON OFF 865 775 690 595 505 425 See Note 4 ON ON ON 865 775 690 595 505 425 See Note 4 Heating (SW1) High Heat Airflow 3 2165 2120 2075 2030 1985 1940 1895 1850 1770 1645 Low Heat Airflow 3 1675 1625 1575 1525 1475 1425 1375 1325 1275 1225 NOTES for Cooling and Heating Air Delivery - CFM (Bottom Return with Filter) 1.Nominal 350 CFM ton cooling airflow is delivered with SW 1-5 and SW2-2 set to OFF. Set both SWl-5 and SW2-2 to ON for +7% airflow (nominal 370 CFM ton) Set SW 1-5 to ON and SW2-2 to OFF for +15% airflow (nominal 400 CFM ton) Set SW 1-5 to OFF and SW2-2 to ON for -7% airflow (nominal 325 CFM/ton) The above adjustments in airflow are subject to motor horsepower range/capacity This applies to Cooling and Low -Cooling airflow, but does not affect continuous fan airflow. 2.Maximum cooling airflow is achieved when switches SW2-6, SW2-7, SW2-8 and SW 1-5 are set to ON, and SW2-2 is set to OFF. 3.All heating CFM's are when comfort/efficiency adjustment switch SW 1-4 is set to OFF. 4.Ductwork must be sized for high -heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not recommended because high -heat operation will be above 1.0 ESP. 5.All airflows on 21" (533 mm) casing size furnaces are 5% less on side -return only installations. 6.Side returns for 24.5" (622 mm) casing sizes require two sides, or a side and bottom to allow sufficient airflow at the return of the furnace. 7.Airflows over 1800 CFM require bottom return, two -side return, or bottom and side return or excessive watt draw may result. A minimum filter size of 20x25" (508 x 635 mm) is required. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12 59TP6B: Product Data IMFXAIMVJM W:/1019411V/4ki1111"4ki[CAN:I Maximum Allowable Exposed Vent Lengths in Unconditioned Space Insulation Table - Ft. Winter Design Unit Size 40,000- BTUH 60,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in. Insulation 1/2-in. Insulation Pipe Dia. in.1/21 1/2 2 21/2 1 1/2 2 2% 1 1/2 2 21/2 1 ' 2 2'/2 3 1% 2 21/2 3 1 1/2 2 2% 3 Temp°F 20 20 20 20 20 50 45 20 60 50 20 30 30 25 20 75 65 60 20 85 75 65 0 10 5 5 20 25 20 20 30 25 15 15 10 10 20 40 30 25 20 45 40 30 -20 5 20 15 10 20 20 15 10 5 20 25 20 15 20 30 25 20 -40 15 10 5 15 15 10 5 1 20 15 15 10 20 20 15 10 80,000 BTUH Unit Size Uninsulated 3/8-in. Insulation 1/2-in. Insulation Winter Pipe Dia. in. 1 1/2 2 2 1/2 3 4 1 t/2 2 21/2 3 4 1 1/2 2 21/2 3 4 Design 20 15 40 40 35 30 15 50 90 75 65 15 50 70 70 70 Temp OF 0 15 20 15 10 5 15 50 45 35 30 15 50 50 40 35 -20 15 10 5 15 35 30 20 15 15 40 30 25 15 -40 10 5 15 25 20 15 5 15 30 25 20 10 Winter Design Unit Size 100,000 BTUH 120,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in. Insulation 1/2-in. Insulation Pipe Dia. in. 2 2 1/2 3 4 2 21/2 3 4 2 21/2 3 4 21/2 F 37 4 21/2 3 4 2 1/2 3 4 Temp OF 20 20 50 40 35 20 80 95 80 20 80 105 90 10 50 40 10 75 95 10 75 105 0 20 20 15 10 20 55 45 35 20 65 55 45 10 20 15 10 55 45 10 65 50 -20 15 10 5 20 35 30 20 20 45 35 25 10 10 10 35 25 10 45 30 -40 10 5 20 25 20 10 20 30 25 15 10 5 10 25 15 10 30 20 Maximum Allowable Exposed Vent Length in Unconditioned Space - Meters 40,000" BTUH 60,000 BTUH Unit Uninsulated 3/8-in. 1/2-in. Uninsulated 3/8-in.Insulation 1/2-in.Insulation Size Insulation Insulation Winter Pipe Design Dia. mm 38 51 64 38 51 64 38 51 64 38 51 64 76 38 51 64 76 38 51 64 76 Temp °C -7 6.1 6.1 6.1 6.1 15.2 13.7 6.1 18.3 15.2 6.1 9.1 9.1 7.6 6.1 22.9 19.8 18.3 6.1 25.9 22.9 19.8 -18 3.0 1.5 1.5 6.1 7.6 6.1 6.1 9.1 7.6 4.6 4.6 3.0 3.0 6.1 12.2 9.1 7.6 6.1 13.7 12.2 9.1 -29 1.5 6.1 4.6 3.0 6.1 6.1 4.6 3.0 1.5 6.1 7.6 6.1 4.6 6.1 9.1 7.6 6.1 -40 4.6 3.0 1.5 4.6 4.6 3.0 1.5 6.1 4.6 4.6 3.0 6.1 6.1 4.6 3.0 Unit 80,000 BTUH Size Uninsulated 3/8-in. Insulation 1/2-in. Insulation Winter Design Pipe Dia. mm 38 51 64 76 102 38 51 64 76 102 38 51 64 76 102 Temp °C -7 4.6 12.2 12.2 10.7 9.1 4.6 15.2 27.4 22.9 19.8 4.6 15.2 21.3 21.3 21.3 -18 4.6 6.1 4.6 3.0 1.5 4.6 15.2 13.7 10.7 9.1 4.6 15.2 15.2 12.2 10.7 -29 4.6 3.0 1.5 4.6 10.7 9.1 6.1 4.6 4.6 12.2 9.1 7.6 4.6 -40 3.0 1.5 4.6 7.6 6.1 4.6 1.5 4.6 9.1 7.6 6.1 3.0 Unit Size 100,000 BTUH 120,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in. Insulation 1/2-in. Insulation Winter Pipe Design Dia. 51 64 76 102 51 64 76 102 51 64 76 102 64 76 102 64 76 102 64 76 102 Temp mm °C -7 6.1 15.2 12.2 10.7 6.1 24.4 28.9 24.4 6.1 24.4 32.0 27.4 3.0 15.2 12.2 3.0 22.9 28.9 3.0 22.9 32.0 -18 6.1 6.1 4.6 3.0 6.1 16.8 13.7 10.7 6.1 19.8 16.7 13.7 3.0 6.1 4.6 3.0 16.8 13.7 3.0 19.8 15.2 -29 4.6 3.0 1.5 6.1 10.7 9.1 6.1 6.1 13.7 10.7 7.6 3.0 3.0 3.0 10.7 7.6 3.0 13.7 9.1- -40 3.0 1.5 6.1 7.6 6.1 3.0 6.1 9.1 7.6 4.6 3.0 1.5 3.0 7.6 4.6 3.0 9.1 6.1 * Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length calculated from Table 3. t Insulation thickness based on R value of 3.5 per in. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13 59TP6B: Product Data MAXIMUM EQUIVALENT VENT LENGTH - FT. (M) NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Deductions from Maximum Equivalent gent Length to determine allowable vent length for each application. Unit Size 40,000 60,0002 80,000 100,0003 120,000 Pipe (in)) 1 Ya 2 2)a 1 n 2 2Ya 3 1 Y2 2 2Ye 3 4 2 2)2 3 4 2r 3 4 Altitude (feet) 0-2000 40 155 185 20 100 175 200 15 55 130 175 200 20 80 175 200 10 75 185 2001-3000 35 150 175 95 165 185 10 49 125 165 185 15 75 165 185 70 175 3001-4000 30 135 160 16 90 155 175 115 155 175 155 175 5 65 165 4001-4500 25 130 155 15 85 150 170 44 110 150 165 10 70 170 60 160 4501-5000 125 145 80 145 165 145 160 65 150 165 5001-6000 20 120 130 75 140 155 41 100 135 150 140 155 155 N/A 6001-7000 15 110 120 13 70 130 145 N/A 38 90 125 140 60 135 145 50 140 7001-8000 10 100 110 10 65 120 135 36 120 125 N/A 55 125 135 46 130 8001-9000 90 95 5 60 155 125 33 80 110 115 1 50 115 125 43 120 9001-10000 5 80 85 N/A 55 1 105 115 30 75 100 105 45 100 115 1 39 1 115 Maximum Equivalent Vent Length - Meters Unit Size 40,000 t 60,0002 80,000 100,0003 120,000 Pipe Dia. (mm) 38 51 64 38 51 64 76 38 51 64 76 102 51 64 76 102 64 76 102 Altitude (meters) 0-610 12.1 47.2 56.3 6'0 30.4 53.3 60.9 4.5 16.7 39.6 53.3 60.9 6.0 24.3 53.3 60.9 3'0 22.8 56.3 611-914 10.6 45.7 53.3 28.9 50.2 56.3 3.0 14.9 38.1 50.2 56.3 4.5 22.8 50.2 56.3 21.3 53.3 915-1219 9.1 41.1 48.7 4.8 27.4 47.2 53.3 35.0 47.2 53.3 47.2 53.3 1.5 19.8 50.2 1220-1370 7.6 39.6 47.2 4.5 25.9 45.7 51.8 13.4 33.5 45.7 50.2 3.0 21.3 51.8 18.2 48.7 1371-1524 38.1 44.1 24.3 44.1 50.2 44.1 48.7 19.8 45.7 50.2 1525-1829 6.0 36.5 39.6 22.8 42.6 47.2 12.4 30.4 41.1 45.7 42.6 47.2 47.2 NA 1830-2134 4.5 33.5 36.5 3.9 21.3 39.6 44.1 NA 11.5 27.4 38.1 42.6 18.2 41.1 44.1 15.2 42.6 2135-2438 3'0 30.4 33.5 3.0 19.8 36.5 41.1 10.9 36.5 38.1 NA 16.7 38.1 41.1 14.0 39.6 2439-2743 27.4 28.9 1.5 18.2 35.0 38.1 10.0 24.3 33.5 35.0 15.2 35.0 38.1 13.1 36.5 2744-3048 1.5 24.3 25.9 NA 16.7 32.0 35.0 9.1 22.8 30.4 32.0 13.7 30.4 35.0 11.8 35.0 1. 40K Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia.) shipped in the loose parts bag or available through Replacement Components required under 10-ft. (3 M) TEVL in all orientations. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level. Failure to use an outlet restrictor may result in flame disturbances or flame sense lock -out. 2. 60K Inducer Outlet Restrictor disk (P/N 3337683-401; .25-in. (32 mm) Dia. available through Replacement Components) required for less than 5-11. (1.5 M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level. 3. 120K Inducer Outlet Restrictor disk (P/N 337683-402; 1.50-in. (38 mm) Dia. available through Replacement Components) required for less than 5-ft. (1.5 M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level. ELBOW CONFIGURATIONS Long Medium Mitered VENT TERMINAL CONFIGURATIONS Concentric I IIL- _ �✓ Standard 2-in., 3-in., or optional 4-in. termination. A13110 Deductions from Maximum Equivalent Vent Length - Ft. (M) Pipe Diameter (in): 1-1/2 2 2-1/2 3 4 Mitered 900 Elbow 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) Medium Radius 901 Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Long Radius 901 Elbow 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) Mitered 450 Elbow 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) Medium Radius 451 Elbow 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) 2.5 (0.5) 1.5 (4.9) 16 0 (0.0) 0 (0.8) (0.5) (4.9) 2.5 1.5 16 (0.8) (0.5) Long Radius 450 Elbow 1.5 (0.5) 1.5 (0.5) 1.5 Tee 1 16 (4.9) 16 (4.9) 16 Concentric Vent Termination a 0 1 0 (0.0) (0.0) 0 1 0 (0.0) (0.0) 0 (0.0) Standard Vent Termination 0 (0.0) NOTE: 1.Use only the smallest diameter pipe possible for venting. Over -sizing may cause flame disturbance or excessive vent terminal icing or freeze-up. 2. NA - Not allowed. Pressure switch will not close, or flame disturbance may result. 3. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction. 4. Size both the combustion air and vent pipe independently, then use the larger size for both pipes. 5. Assume the two 45 ° elbows equal one 90' elbow. Wide radius elbows are desirable and may be required in some cases. 6. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 7. The minimum pipe length is 5 ft. (2 M) linear feet (meters) for all applications. 8. Use 3-in. (76 mm) diameter vent termination kit for installations requiring 4-in. (102 mm) diameter pipe Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 59TP613: Product Data Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 4. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer's data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe. Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Table 3. Example 1 A direct -vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE: 70 feet (22 M) of vent pipe, 65 feet (20 M) of combustion air inlet pipe, (3) 90' long -radius elbows, (2) 45' long -radius elbows, and a factory accessory concentric vent kit. Can this application use 2" (50 mm ND) PVC/ABS DWV vent piping? Measure the required linear length of air inlet and vent 70 ft. Use length of the longer of the vent pipe; insert the longest of the two here 1 (22 M) or air inlet piping system Add equiv length of (3) 900 long -radius elbows 3 ft. 9 ft. From Deductions from Maximum Equivalent (use the highest number of elbows for either the vent or 3 x (0.9 M) _ (2.7 M) Vent Length - Ft. (M) Table. inlet pipe) Add equiv length of (2) 450 long -radius elbows 1.5 ft. 3 ft. From Deductions from Maximum Equivalent (use the highest number of elbows for either the vent or 2 x (0.5 M) _ (0.9 M) Vent Length - Ft. (M) Table. inlet pipe) Add equiv length of factory concentric vent term 0 ft. From Deductions from Maximum Equivalent Vent Length - Ft. (M) Table. Add correction for flexible vent pipe, if any 0 ft. From Vent Manufacturer's instructions; zero for PVC/ABS DWV Total Equivalent Vent Length (TEVL) 82 ft. (25 M) Add all of the above lines Maximum Equivalent Vent Length (MEVL) 95 ft. For 2" pipe from Maximum Equivalent Vent (29 M) Length - Ft. (M) Table. Is TEVL less than MEVL? YES Therefore, 2" pipe MAY be used Example 2 A direct -vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE: 100 feet (30 M) of vent pipe, 95 feet (29 M) of combustion air inlet pipe, (3) 90' long -radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6.1 M) of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe. VERIFY FROM POLYPROPYLENE VENT MANUFACTURER'S INSTRUCTIONS for the multiplier correction for flexible vent pipe. Can this application use 60mm o.d. (2") polypropylene vent piping? If not, what size piping can be used? Measure the required linear length of RIGID air inlet and vent pipe; insert the longest of _ 80 ft. Use length of the longer of the vent the two here: 100 ft. Of rigid pipe - 20 ft. Of flexible pipe (24 M) or air inlet piping system Add equiv length of (3) 900 long -radius elbows (use the 3 x 5 ft. _ 15 ft. highest number of elbows for either the vent or inlet pipe) (1.5 M) (4.6 M) Add equiv length of 451 long -radius elbows (use the highest number of elbows for either the vent or 0 x = (� M) Example from polypropylene vent inlet pipe) manufacturer's instructions, Verify from vent manufacturer's instructions. Add equiv length of factory concentric vent term 9 x 3.3 ft = 30 ft. (0.9 M) (9 M) Add correction for flexible vent pipe, if any 2` x 20 ft. (6.1 M) = 40 ft. (12.2 M) * VERIFY FROM VENT MANUFACTURER'S INSTRUCTIONS; For example only, assume 1 meter of flexible 60mm (2") or 80mm (Y) polypropylene pipe equals 2.0 meters (6.5 ft.) of PVC/ABS pipe. Total Equivalent Vent Length (TEVL) 165M. Add all of the above lines Maximum Equivalent Vent Length (MEVL) 95 ft. For 2" pipe from Maximum Equivalent Vent (29 M) Length - Ft. (M) Table. Is TEVL less than MEVL? NO Therefore, 60mm (2") pipe may NOT be used; try 80mm (Y) Maximum Equivalent Vent Length (MEVL) 185 ft. For 3" pipe from Maximum Equivalent Vent (57 M) Length - Ft. (M) Table. Is TEVL less than MEVL? YES Therefore, 80mm (Y) pipe MAY be used Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 15 59TP6B: Product Data RETURN AIR TEMPERATURE 1111161TA Ll I This furnace is designed for continuous return -air minimum temperature of 60°F (15°C) db or intermittent operation down to 55°F (13°C) db such as when used with a night setback thermometer. Return -air temperature must not exceed 80°F (27°C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls. SUPPLY 32o F/ 0° C MINIMUM INSTAL AMBIENT OR FREEZE PROTECTION REQUIRED 1 1/4-IN. TYP PLENUM OPENING F fA Z ANv MAX80 T / 27°C m FACTORY -SUPPLIED C" FIELD -INSTALLED INSULATION A 10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 (0 mm) Front (Combustion air openings in furnace and in structure) 1 in. (25 mm) Required for service 24 in. (610 mm)t All Sides of Supply Plenum* 1 in. (25 mm) Sides 0 (0 mm) Vent 0 (0 mm) Top of Furnace 1 in. (25 mm) *. Consult your local buildin codes �. Recommended COMBUSTION -AIR PIPE FOR NON -DIRECT (1-PIPE) VENT APPLICATION 2-IN. (51 mm) DIA. FIELD -SUPPLIED MITERED RADIUS 2-IN. (51 mm) DIA. PVC 90, ELBOW PVC PIPE 12" (300 mm) MINIMUM A 12376 NOTE: See Installation Instructions for specific venting configurations. LOCATING TAB 60 Downfoow Subbase A97427 A88207 A88202 One base fits all furnace sizes. The base is designed to be installed between the furnace and a combustible floor when no coil box is used or when a coil box other than a Carrier cased coil is used. It is CSA design certified for use with Carrier branded furnaces when installed in downflow applications. DIMENSIONS (IN. / MM) FURNACE PLENUM OPENING FLOOR OPENING HOLE NO. FOR CASING FURNACE IN DOWNFLOW APPLICATION WIDTH A B C D WIDTH ADJUSTMENT 14-3/16 (360) Furnace with or without Cased Coil Assembly or 11-3/16 (322) 19 (483) 13-7/16 (341) 20-5/8 (600) 4 Coil Box 17-1/2 (445) Furnace with or without Cased Coil Assembly or 15-1/8 (384) 19 (483) 16-3/4 (426) 20-5/8 (600) 3 Coil Box 21 (533) Furnace with or without Cased Coil Assembly or 18-5/8 (396) 19 (483) 20-1/4 (514) 20-5/8 (600) 2 Coil Box 24-1/2 (622) Furnace with or without Cased Coil Assembly or 22-1/8 (562) 19 (483) 23-3/4 (603) 20-5/8 (600) 1 Coil Box *. The plenum should be constructed 1/4-in. (6 mm) smaller in width and depth than the plenum dimensions shown above. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 59TP6B: Product Data Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion -air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe. MEDIA FILTER CABINET (OPTIONAL ACCESSORY) ) 600.. (600mm (594.m4mm) Centerline Screw Slots 25-5/8" (651 mm) 24.1,4. 16mm 6with Opening Flanges Bent) 23-1/8" (588mm) O - Opening A Duct Side F 53m --, (146m) Medabia Finetilter C A B 16" 406mm 17 432mm 161. 406mm 20" 508mm 21" 533mm 20" 508mm 24' 610mm 25" 635mm 24" 610mm NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return. A12428 TYPICAL WIRING SCHEMATIC - - - - FIELD 24-VOLT WIRING - - - - FIELD 115-, 208/230-, 460-VOLT WIRING FACTORY 24-VOLT WIRING FACTORY 115-VOLT WIRING NOTE 2 1-STAGE FIVE Q QC Q Q Q THERMOSTAT FIELD -SUPPLIED WIRE TERMINALS FUSED DISCONNECT BLOWER THREE -WIRE DOOR HEATING- 208/230- OR SWITCH ONLY •' ' ' 460-VOLT IN • THREE _BLK •y BLK 7- C O _ ♦ _ - _� _ PHASE WHT �... _ _ HT Q '.... ' VOLT �-I N • - T GND NOTE 1 R Yly2'----------'- SINGLE 115-VOLT FIELD- JUNCTION , •. IPHASE SUPPLIED BOX LO O - - - - - - - - - ' ♦GND FUSED DISCONNECT GG - - - - - - - - - - - CONDENSING UNIT 24-VOLT TERMINAL NOTES: 1. Connect Y/Y2-terminal as shown for proper operation. BLOCK 2. Some thermostats require a "C" terminal connection as shown. FURNACE 3. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. A11401 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17 59TP6B: Product Data GUIDE SPECIFICATIONS General System Description Furnish a 4-way multipoise gas -fired condensing furnace for use with natural gas or propane (factory - authorized conversion kit required for propane). Quality Assurance Unit will be designed, tested and constructed to the current ANSI Z 21.47/CSA 2.3 design standard for gas -fired central furnaces. Unit will be third party certified by CSA to the current ANSI Z 21.47/CSA 2.3 design standard for gas -fired central furnaces. Unit will carry the CSA Blue Star® and Blue Flame® labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register. Unit will be certified for capacity and efficiency and listed in the latest AHRI Consumer's Directory of Certified Efficiency Ratings. Unit will carry the current Federal Trade Commission Energy Guide efficiency label. Delivery. Storage. and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Primary Heat Exchangers Primary heat exchangers shall be 3-Pass corrosion -resistant aluminized steel of fold -and -crimp sectional design and applied operating under negative pressure. Secondary Heat Exchangers Secondary heat exchangers shall be of a stainless steel flow -through of fin -and -tube design and applied operating under negative pressure. Controls Controls shall include a micro -processor -based integrated electronic control board with at least 16 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self -test feature that checks all major functions of the furnace, and a replaceable automotive -type circuit protection fuse. Multiple operational settings available, including separate blower speeds for low heat, high heat, low cooling, high cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be selectable between 325 to 400 CFM per ton of air conditioning. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when a T6-PRH is selected as the thermostat. Operating Characteristics Heating capacity shall be Btuh output capacity. Btuh input; Fuel Gas Efficiency shall be AFUE. Air delivery shall be cfin minimum at 0.50 in. W.C. external static pressure. Dimensions shall be: depth in. (mm); width in. (mm); height in. (mm) (casing only). Height shall be in. (mm) with A/C coil and in. (mm) overall with plenum. Electrical Requirements Electrical supply shall be 115 volts, 60 Hz, single-phase (nominal). Minimum wire size shall be AWG; maximum fuse size of HACR-type designated circuit breaker shall be amps. Special Features Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements. Warrantv (for inclusion by soecifvina enaineer) U.S. and Canada only. Warranty certificate available upon request Equipment Blower Wheel and ECM Blower Motor Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed ball bearings, of hp, and have infinitely variable speed from 600-1200 RPM operating only when motor inputs are provided. Blower motor shall be direct drive and soft mounted to the blower housing to reduce vibration transmission. Filters Furnace shall have reusable -type filters. Filter shall be in. (mm) X in. (mm). An accessory highly efficient Media Filter is available as an option. Media Filter. Casing Casing shall be of .030 in. thickness minimum, pre -painted steel. Draft Inducer Motor Draft inducer motor shall be two -speed PSC design. © 2020 Carrier. All riehts reserved. Edition Date: 11/20 Catalog No: 59TP6B-04PD Replaces: 59TP6B-03 PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18