BLD2022-0441_Manufacturer_Specifications_and_Installation_Instructions_3.29.2022_1.41.16_PM_2768285A ELECTRICAL DATA UNIT SIZE - SERIES (VOLTAGE) V/PH OPER VOLTS* COMPR FAN MCA MAX FUSE** or CKT BRK AMPS MAX MIN LRA RLA FLA j 018-A (N) 208/230/1 253 197 56.3 9.0 0.50 11.8 20 024-A (N) 62.9 10.9 0.50 14.1 25 030-A N 73.0 14.1 0.70 18.3 30 036-A (N) 77.0 14.1 1.20 18.8 30 048-A (N) 124.0 18.5 1.20 24.3 40 060-A (N) 152.5 23.7 1.45 31.1 50 036-A (P) 208/230/3 253 197 71.0 9.0 1.20 12.5 20 048-A (P) 83.1 13.7 1.20 18.3 30 060-A (P) 110.0 15.9 I 1.45 21.4 35 036-A (E) 460/3 506 414 38.0 5.6 0.60 7.6 15 048-A (E) 41.0 6.2 0.60 8.4 15 060-A (E 5i . 7.1 0.80 1 9.7 115 LEGEND: FLA - Full Load Amps HACR - Heating, Air Conditioning, Refrigeration LRA - Locked Rotor Amps NEC - National Electrical Code RLA - Rated Load Amps (compressor) * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time -Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 A -WEIGHTED SOUND POWER (dBA) Standard Unit Size Rating (dBA) 18 69 24 66 30 j 68 36 71 48 70 60 73 Typical Octave Band Spectrum (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 50.5 57.0 59.5 64.5 60.5 53.5 43.0 50.5 58.5 60.5 59.5 56.5 51.0 41.5 55.5 59.5 61.5 63.5 60.0 58.0 49.5 59.5 59.5 62.0 65.5 63.5 62.0 55.0 57.5 59.5 64.0 66.0 63.0 60.5 54.5 60.0 61.5 64.5 67.0 66.0 65.5 58.0 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI. A -WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD Unit Size Standard Rating (dBA) Typical Octave Band Spectrum (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 18 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5 24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5 30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 57.5 59.5 63.0 1 65.0 62.5 60.0 54.0 60 73 61.0 62.0 64.0 67.0 65.5 65.5 57.5 NOTES: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). Accessory sound shield will not accommodate unit sizes 18 and 24. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE -SERIES REQUIRED SUBCOOLING ° F ° C 18 12(6.7) 24 12(6.7) 30 12(6.7) 36 8(4.4) 48 12(6.7) 60 10(5.6) DIMENSIONS - ENGLISH A 00 n o c%l >t = rE5 O=NO C.4 m N ap C N N MINIMUM UNIT SIZE MOUNTING PAD DIMENSIONS 18,24 il' % 42' 30.36.48,60 24, N 50, m 1 CLEARANCE REOUIREMENTS• SINGLE UNIT APPLICATIONS' WITH COIL FACING WALL: ALLOW 6 IN. MINIMUM CLEARANCE ON COIL SIDE AND COIL END AND 20 IN MINIMUM CLEARANCE ON FAN SIDE WITH FAIL FACING WALL ALLOW 8 IN MINIMUM CLEARANCE ON FAN SIDE AND 6 IN ON COIL END AND 20 IN MINIMUM CLEARANCE ON COIL '111 MULTI - UNIT APPLICATIONS: ALLOW 24 IN ON CLEARANCE BETWEEN FAN AND COIL SIDES OF MOLTIHEE UNITS ARRANGE UNITS 50 DISCHARGE OF ONE DOES NUT LNIER [MEET OF ANOTHER WHEN TWO UNITS ARE 1NCIALLED END TO END WITH THE COIL ENDS FACING EACH OTHER ALLOW 12 IN MINIMUM CLEARANCE BETWEEN UNITS C OMPRESSOA ENU SEA4ICE CLEARANCE: ALLOW 24 IN MINIMUM CLEARANCE ON COMPRESSOR ENU W'H EN UNITS ARE STACKED OR IERE IS LESS THAN 40 IN OF CLEARANCE ABOVE THE TOP OF THE UNIT IF fHI RE IS 40 IN CLEARANCE ABOVE UN AND THE TOP PANEL IS ACCESSIBLE FOR REMOVAL ALLOW B IN. MINIMUM CLEARANCE ON COMPRESSOR END FOR ;ERVICE. IMPORIANI: WHEN INSTALLING SINGLE OR 14ULTIFEE UNITS IN AN ALCOVE. ROOF WELL. OR PARIIALLY ENCLOSED AREA. EN`.URE THERE IS ADEOUATE VENTILATION TO PREVENI RLCI RC UL AT I ON OF DISCHARGE AIR. 2 MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING 1 l2" MODE IS 55�F, MAX. 125'F. 3. SEHIES DESIGNATION IS THE 13TH POLITION OF THE UNIT MODEL NUMBER. 4. CENIEN OF GRAVITY 4 3/16" 5. ALL DIMENSIONS ARE 1N "INCHES" UNLESS NOTED. FIELD CONTROL SUPPL 'IRE ENTRY 7ld" HOLE W/GROMMET —OM VAPOR LINE CONN. FEMALE SWEAT CONN. --03/E" LIOUID LINE FEMALE SWEAT CONN /—TfELD POWER SUPPLY CONN. %HOLE SIZES PH OVIDED: /&" HOLE WITH 0 I 1/6" KNOC KOUI AND IONS 0 1 3/E" KNOCKOUT 1 7/1D" w