Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-0440_Other_4.6.2022_12.04.07_PM_2785725
FEEDER SCHEDULE TOTAL MODULE(S) ENPHASE Q CABLES + #6MAX AC POWER OUT 15.95k7VA BARE EGC IN OPEN AIR (10) #10 THWN-2 +(1) #8 GND IN 1" EMT TOTAL DC POWER 18.98kW Vmpp ® NOT USED OPERATING VOLTAGE 240V impp (2) #3 THWN-2 +(1) #3 THWN-2 NEUT +(1) #8 GND IN 1" EMT VOC ® NOT USED ® (2) #3 THWN-2 +(1) #3 THWN-2 NEUT +(1) #8 GND IN 1" PVC O NOT USED - o ® NOT USED PUGET SOUND SOLAR FLAG NOTES: 805 Rainier Ave S MAIN BONDING JUMPER, LINE SIDE TAP BEFORE MAIN BREAKER IN COMPLIANCE WITH NEC 2020 705.11 Seattle, WA 98144 2 MONITORING DEVICE CT LEADS, (2) 18 AWG IN 1/2" EMT Tel: 206-706-1931 3 NOT USED NOT USED x NOT USED � o ioa © NOT USED 3 N a oak �o 1 DAY U_I Bz"' o o 0 LEGEND � w N GROUNDING Q z � i BREAKER i Q Q � _ w SOLAR MODULE ❑J JUNCTION BOX J � O PRODUCTION ( E METER -p OM NET METER Q UJ ='w �- FUSED AC DISCONNECT - UNFUSED AC o a 0 DISCONNECT o MI MICROINVERTER Mi Mi im im O1 SUBPANEL + DC OPTIMIZER zoo STRING OF 3 15 6MODULES 125A11- owe n n 100A FUSED AC �� UTILITY 3 I� I� DISCONNECT, O SERVICE 20A M M STRING OF M M 1 J M O O 90A FUSES 13 MODULES oho 20A 200A LOAD 0 PRELIMINARY DESIGN 322/12 20A CENTER REV DESCRIPTION DATE M M STRING OF M M O 200A MAIN DRAWN BY AB 10 MODULES 20A o 200A BUS CHECKED BY NSG �-1 10A o PROJECT #: 15294 a Mi Mi m m O ^ SALES: WILL SUMNER STRING OF PM: NICK ST GERMAIN a 13 MODULES `e PM CELL: (925) 446-7093 0 B $ IQ 3 ENVOY ELECTRICAL ONE LINE M� M� STRING OF �M �M � DIAGRAM 13 MODULES l ROOF INTERIOR EXTERIOR EXISTING PV-102 STRING MAX AC CONTINUOUS OUTPUT 15.73A SYSTEM MICROINVERTER TOTAL 55 SYSTEM PV STRING SIZING DETAILS STRING MAX MICROS 13 MAX AC CONTINUOUS OUTPUT 66.55A MODULE DATA MODULE MODEL Mission Solar MSE345SX5T 33.37V 10.34A 41.00V V TEMP COEFF-0.262%/°C MIN DESIGN TEMP -40°C INVERTER MODEL ENPHASE 107PLUS-72-2-US MAX DC IN 60V MAX CURRENT IN 15A I 10.92A MAX CURRENT OUT 1.21A INVERTER DATA MAX AC OUT 290VA CONDUIT CURRENT CALCULATIONS CURRENT CARRYING CONDUCTORS 10 ADJUSTMENT FACTOR 50% #10 THWN-2 ALLOWABLE CURRENT 40A ADJUSTED ALLOWED CURRENT 20A STRING MAX AC OUTPUT CURRENT 15.7A OVERCURRENT PROTECTION MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV TOTAL 83.2A N/A ° PV STRING MAX 19.7A 20A ° SOLAR PV SYSTEM DETAILS 55 MAX AC POWER OUT 15.95kVA MODULE DATA MODULE MODEL Mission Solar MSE345SX5T 33.37V 10.34A 41.00V V TEMP COEFF-0.262%/°C MIN DESIGN TEMP -40°C INVERTER MODEL ENPHASE 107PLUS-72-2-US MAX DC IN 60V MAX CURRENT IN 15A I 10.92A MAX CURRENT OUT 1.21A INVERTER DATA MAX AC OUT 290VA CONDUIT CURRENT CALCULATIONS CURRENT CARRYING CONDUCTORS 10 ADJUSTMENT FACTOR 50% #10 THWN-2 ALLOWABLE CURRENT 40A ADJUSTED ALLOWED CURRENT 20A STRING MAX AC OUTPUT CURRENT 15.7A OVERCURRENT PROTECTION MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV TOTAL 83.2A N/A ° PV STRING MAX 19.7A 20A ° SOLAR PV SYSTEM DETAILS 55 MAX AC POWER OUT 15.95kVA CONDUIT CURRENT CALCULATIONS CURRENT CARRYING CONDUCTORS 10 ADJUSTMENT FACTOR 50% #10 THWN-2 ALLOWABLE CURRENT 40A ADJUSTED ALLOWED CURRENT 20A STRING MAX AC OUTPUT CURRENT 15.7A OVERCURRENT PROTECTION MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV TOTAL 83.2A N/A ° PV STRING MAX 19.7A 20A ° SOLAR PV SYSTEM DETAILS 55 MAX AC POWER OUT 15.95kVA OVERCURRENT PROTECTION MAX AC OUTPUT 125 % SAFETY OCPD SIZE PV TOTAL 83.2A N/A ° PV STRING MAX 19.7A 20A ° SOLAR PV SYSTEM DETAILS 55 MAX AC POWER OUT 15.95kVA SOLAR PV SYSTEM DETAILS 55 MAX AC POWER OUT 15.95kVA SUPPLY CALCULATIONS