Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-0440_Manufacturer_Specifications_and_Installation_Instructions_4.6.2022_12.04.01_PM_2785724
Positive Power Tolerance Class leading power output -0 to +3% FRAME -TO -FRAME WARRANTY Degradation guaranteed not to exceed 2% in year one and 0.58% annually from years two to 30 with 84.08% guaranteed in year 25. For more information visit www.missionsolar.com/warranty CERTIFICATIONS C C isC �` US C If you have questions or concerns about LISTED certification of our products in your area, UL 61730 / IEC 61215 / IEC 61730 / IEC 61701 please contact Mission solar Energy. True American Quality True American Brand Mission Solar Energy is headquartered in San Antonio, Texas, where we manufacture our modules. We produce American, high quality solar modules ensuring the highest in -class power output and best in -class reliability. Our product line is tailored for residential, commercial and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations, proving excellent performance over the long term. Demand the best. Demand Mission Solar Energy. OCertified Reliability L • Tested to UL 61730 &IEC Standards • PID resistant • Resistance to salt mist corrosion Advanced Technology • 6 Busbar • Passivated Emitter Rear Contact • Ideal for all applications Extreme Weather Resilience • Up to 5,600 Pa front load & 5,631 Pa back load • Tested load to UL 61730 • 40 mm frame BAA Compliant for Government Projects • Buy American Act • American Recovery & Reinvestment Act ASSEMBLED 25- YEAR C-SA2-MKTG-0025 REV 4 05/05/2021 www.missionsolar.com I info@missionsolar.com 68.8 Class Leading 340-350W [UNITS: MMANi 1748 68.8 MSE PERC 60 PRODUCT TYPE MSE SX5T ( =Pmax) Power Output I Pmax Wo 345 Module Efficiency % 18.5 18.7 1054 41.5 Tolerance % 0/+3 0/+3 Grounding Hole (x2) REARVIEW MSE345SX5T: 345WP, 60 CELL SOLAR MODULE Current -voltage characteristics with dependence on irradiance and module temperature Cells Temp. =25 °C 12 Incident Irrd. = 1000 W/m2 io Incident Irrd. = 800 W/m2 Q Z 8 Incident Irrd. = 600 W/m2 W e X Incident Irrd. = 400 W/m2 U 4 Incident Irrd. = 200 W/m2 2 o _ 0 10 23 ao ao VOLTAGE (V) IEC 61215,61730,61701 UL 61730 CEC c&US Sl'1D LISTED Mission Solar Energy 8303 S. New Braunfels Ave., San Antonio, Texas 78235 www.missionsolar.com I info@missionsolar.com Short Circuit Current Isc V 10.86 10.92 39s Open Circuit Voltage Voc A 40.82 41.00 Rated Current ImP V 10.24 10.34 77 J Rated Voltage VmP V 33.20 33.37 3 1 Fuse Rating A 20 20 System Voltage V 1,000 1,000 350 19.0 0/+3 10.97 41.18 10.44 33.52 20 1,000 Normal Operating Cell Temperature (NOCT) 44.43°C (t3.7%) Temperature Coefficient of Pmax -0.361%/°C Temperature Coefficient of Voc 0.262%/°C Temperature Coefficient of Isc 0.039%/°C Maximum System Voltage 1,000Vdc Operating Temperature Range -40°C (-40T) to +85°C (185°F) Maximum Series Fuse Rating 20A Fire Safety Classification Type 1 Front & Back Load Up to 5,600 Pa front and 5,631 Pa (UL Standard) back load, Tested to UL 61730 Hail Safety Impact Velocity 25mm at 23 m/s Solar Cells P-type mono -crystalline silicon Cell Orientation 60 cells (6x10) Module Dimension 1748mm x 1054mm x 40mm Weight 20.3 kg (44.8 lbs.) Front Glass 3.2mm, tempered, low -iron, anti -reflective Frame Anodized Encapsulant Ethylene vinyl acetate (EVA) Junction Box Protection class IP67 with 3 bypass -diodes Cable 1.0m, Wire 4mm2 (12AWG) Connector Staubli PV-KBT4/611-UR and PV-KST4/611-UR, MC4, Renhe 05-8 SHIPPING.- - ContainerFeet Ship To Pallet Panels 345 W Bin 53' Most States 34 884 304.98 kW Double Stack CA 28 728 251.16 kW Weight PALLET [26 PANELS] Height Width Length 1263 lbs. 47.5 in 46 in 70.25 in (573 kg) (120.65 cm) (116.84 cm) (178.43 cm) C-SA2-MKTG-0025 REV 4 05/05/2021 www.missionsolar.com I info@missionsolar.com Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and The high-powered smart grid -ready Enphase IQ 7 MicroTM and Enphase IQ 7+ MicroTM IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters U� To learn more about Enphase offerings, visit enphase.com Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ EnvoyTM, Enphase IQ BatteryTM, and the Enphase Enlighten' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double -insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. � ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings' Module compatibility Maximum input DC voltage Peak power tracking voltage Operating range Min/Max start voltage Max DC short circuit current (module Isc) Overvoltage class DC port DC port backfeed current 235 W - 350 W + 60-cell PV modules only 48 V 27V-37V 16V-48V 22V/48V 15A 0A 235 W - 440 W + 60-cell and 72-cell PV modules 60 V 27V-45V 16V-60V 22V/60V 15A 0A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range2 240 V / 208 V / 240 V / 208 V / 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit3 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 % 97.6 % 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range Relative humidity range Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Dimensions (WxHxD) Weight Cooling Approved for wet locations Pollution degree Enclosure -400C to +65°C 4%to 100%(condensing) MC4 (or Amphenol H4 UTX with additional Q-DCC-S adapter) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4: order ECA-S20-S22 PV2 to UTX: order ECA-S20-S25 212 mm x 175 mm x 30.2 mm (without bracket) 1.08 kg (2.38 Ibs) Natural convection - No fans Yes PD3 Class II double -insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com u E N P H AS E © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 Data Sheet Enphase Networking Enphase IQ Envoy The Enphase IQ EnvoyTM communications gateway delivers solar production and energy consumption data to Enphase EnlightenTMmonitoring and analysis software for comprehensive, remote maintenance and management of the Enphase IQ System. With integrated revenue grade production metering and optional consumption monitoring, Envoy IQ is the platform for total energy management and integrates with the Enphase EnsembleTMand the Enphase IQ BatteryTM Smart • Enables web -based monitoring and control • Bidirectional communications for remote upgrades • Supports power export limiting and zeroexport applications Simple • Easy system configuration using Enphase Installer Toolkit'" mobile app • Flexible networking with Wi-Fi, Ethernet, or cellular Reliable • Designed for installation indoors or outdoors • Five-year warranty ENPHASE To learn more about Enphase offerings, visit enphase.com �./ Enphase IQ Envoy MODEL NUMBERS Enphase IQ Envoy'" Enphase IQ Envoy communications gateway with integrated revenue grade PV ENV-IQ-AM1-240 production metering (ANSI C12.20 +/- 0.5%) and optional consumption monitoring (+/- 2.5%). Includes one 200A continuous rated production CT (current transformer). ACCESORIES (Order Seperately) Enphase Mobile Connect" Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-M1 (4G based LTE-M/5-year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin CELLMODEM-MI-B (4G-based LTE-M1/5-year data plan) Islands, where there is adequate cellular service in the installation area.) Consumption Monitoring CT Split -core consumption CTs enable whole home metering. CT-200-SPLIT Ensemble Communications Kit Installed at the IQ Envoy. For communications with Enphase Encharge' storage COMMS-KIT-01 and Enphase Enpower" smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'" and allows wireless communication with Encharge and Enpower. POWER REQUIREMENTS Power requirements 120/240 VAC split -phase. Max 20 A overcurrent protection required. Typical Power Consumption 5W CAPACITY Number of microinverters polled Up to 600 MECHANICAL DATA Dimensions (WxHxD) 21.3 x 12.6 x 4.5 cm (8.4" x 5" x 1.8") Weight 17.6 oz (498 g) Ambient temperature range -40° to 65° C (-40° to 149° F) -40° to 46° C (-40° to 115° F) if installed in an enclosure Environmental rating IP30. For installation indoors or in an NRTL-certified, NEMA type 3R enclosure. Altitude To 2000 meters (6,560 feet) Production CT Limited to 200A of continuous current / 250A OCPD — 72kW AC Internal aperture measures 19.36mm to support 250MCM THWN conductors (max) Consumption CT For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.84" x 0.96" (21.33mm x 24.38mm) to support 3/0 THWN conductor CT wire insulation rating of 600V INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Mobile CELLMODEM-M1 (4G) or CELLMODEM-M1-B (4G). Not included. Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. COMPLIANCE Compliance UL 61010-1 CAN/CSA C22.2 No. 61010-1 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 (PV production only) To learn more about Enphase offerings, visit enphase.com E N P H AS E © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Envoy, and other trademarks or service names are the trade- `/ marks of Enphase Energy, Inc. Data subject to change. 2021-03-29 SUNM Y r■■� '= SOLAR'S FASTE ATTACHMENT NanoMountO Rafter or Deck Mount Damaging roof shingles used to be one of a solar installers' worst challenges. Now, the easy, affordable solution is NanoMount°. SunModo's patented solar mounting innovation. The mount eliminates the need for lifting shingles and dramatically reduces the installation time. ^^SUNMe"A11611111111111' 5 levels of protection water penetration 360-degree positioning, serrated surface on both sides for rail mounting Aesthetically pleasing unibody aluminum cast construction Alignment markers enable easy installation against Open L-Foot for fast rail attachment 1 4 Deck Screws for Deck Mount or 1 Lag Bolt for Rafter Mount Integrated Ultra Soft Weather Resistant gasket 0a, 14110V Application 1 Residential roof coverings, commercial single -ply roof membranes Material High grade aluminum, 304 stainless steel hardware Finish Black powder coating Roof Attachment Rafter and decking Structural integrity IBC and IRC Compliant Warranty 25 years SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com __I& I RON RI DGE Flush Mount System Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System ® Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. - Design Assistant ® Online software makes it simple to create, share, and price projects. 20-Year Warranty Twice the protection offered by competitors. XR Rails O XR10 Rail i A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear and black finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear and black finish Clamps & Grounding O — UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Attachments 6 — FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill and black finish Resources Stopper Sleeves _L Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish Slotted L-Feet XR1000 Rail Bonded Splices A heavyweight mounting All rails use internal splices rail for commercial projects. for seamless connections. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Drop -in design for rapid rail Bond and attach XR Rails attachment. to roof attachments. Secure rail connections Slot for vertical adjusting Clear and black finish esign Assistant o from rough layout to fully E:Jngineered system. For free. o to IronRidge.com/design • T & Square Bolt options • Nut uses 7/16" socket • Assembled and lubricated • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training 0%w Earn free continuing education credits, POP while learning more about our systems. Go to IronRidge.com/training © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.30 Use IronRidge's Microinverter Kit to bond compatible microinverters and power optimizers to the racking system. Insert Microinverter Kit T-bolt into top rail slot. Place compatible microinverter or power optimizer into position and tighten hex nut to 80 in-Ibs. Q If installing in areas with ground snow loads greater than 40 psf, install MLPE devices directly next to module frame edge COMPATIBLE PRODUCTS Enphase M250-72, 250-60, M215-60, C250-72, S230, S280, IQ 6, IQ 6+, IQ IQ7, IQ 7A, IQ 7+9 IQ 7X, Q Aggregator Darfon MIG240, MIG300, G320, G640 Solar Edge P300, P320, P340, P370, P400, P405, P485, P505, P600, P700, P730, P800p, P800s, P850, P860 SMA RoofCommKit-P2-US, TS4-R Module Retrofit Kits (TS4-R-S, TS4-R-0, TS4-R-F) Tiao Tigo Access Point (TAP) TS4-R-X (where X can be F, M, O, or S) TS4-R-X-DUO (where X can be M, O, or S) TS4-A-X (where X can be F, 217, O, O-DUO, or S) AP Systems QS1, YC600 Q Remove Grounding Washer on AP Systems QS1 and YC600 inverters before installing to XR rails. Q Remove the Stainless Steel Clip on Tigo-"A" MLPE Devices before attaching to XR rails. Q Use the number of IronRidge Microinverter kits allowed by the MLPE mounting flange. Some will require 1 kit and others 2 kits. On AP systems equipment, ding Washer Two Microinverter Kits Required (80 in-Ibs) SYSTEMS USING ENPHASE MICROINVERTERS OR SUNPOWER AC MODULES IronRidge systems using approved Enphase products or SunPower modules eliminate the need for lay -in lugs and field installed equipment grounding conductors (EGC). This solution meets the requirements of UL 2703 for bonding and grounding and is included in this listing. COMPATIBLE PRODUCTS un ow r Modules with model identifier Ab-xxx-YY and InvisiMount (G5) 46mm frame; where "A" is either E, or X; "b" can be 17, 18, 19, 20, 21, or 22; and "YY" can be C-AC, D-AC, BLK-C-AC, or BLK-D-AC. Enphase Microinverters M250-72, M250-60, M215-605 C250-72, and Engage cables ETXX-240, ETXX-208, ETXX-277. Q A minimum of two inverters mounted to the same rail and connected to the same Engage cable are required. Q The microinverters or Sunpower AC modules must be used with a maximum 20 A branch rated overcurrent protection device (OCPD). Q If an AC module is removed from a circuit for maintenance, you must first disconnect AC power and then install a temporary EGC to bridge the gap by inserting an AC extension cable (or via other NEC -compliant means), in order to maintain effective ground continuity to subsequent modules. ML Use IronRidge's Microinverter Kit to bond compatible microstroage devices to the racking system. Insert Microinverter Kit T-bolt into top rail slot. Place compatible microstorage into position and tighten hex nut to 80 in-Ibs. COMPATIBLE PRODUCTS PHAZR PHAZR Devices PHAZR-X, where X is 6-12. Solpad Solpad Inverter model SI-1k Solpad Battery Storage model SB-2K Solpad Junction Box model SJB-4k Q Running a separate equipment grounding conductor to the PHAZR or Solpad devices is not required. Q If installing in areas with ground snow loads greater than 40 psf and underneath a module, install PHAZR and Solpad devices as close as possible to module frame edge. Q Solpad may only be installed on XR-100 and XR-1000 Q Solpad may only be installed with modules having a frame thickness of 35mm or greater. Q Use the number of Iron Ridge Microinverter kits allowed by the microstorage mounting flange. Some will require 1 kit and others 2 kits. FRAMELESS MODULE KITS Insert Frameless Kit T-bolt in top rail slot. Place star washer over T-bolt, allowing it to rest on top of rail. Secure module clamps with a hex nut and torque to 80 in-Ibs. COMPATIBLE PRODUCTS Sunforson Sunforson silver or black SFS-UTMC-200(B) mid and SFS-UTEC- 200(B) end clamps. Sunpreme Sunpreme silver or black mid and end clamps with part numbers 7500105X where "X" is 1, 5, 6 or 7. Ironridae IronRidge silver or black mid and end clamps with part numbers FMLS-XC-001-Y where "X" is E or M and "Y" is B or blank. 4 Follow module manufacturer's installation instructions to install the module clamps. 4 Frameless modules require using a Grounding Lug on every rail. 4 For Sunpreme Modules Only: If required to use slide prevention hardware, see Module Slide Prevention Addendum (Version 1.10). Microinverter 't (80 in-Ibs) PHAZR Solpad �- Module Clamp (80 in-Ibs) FLUSH MOUNT INSTALLATION MANUAL - 12 MODUL,r&COMPATIBILI +il The Flush Mount System may be used to ground and/or mount a PV module complying with UL 2703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. Amerisolar modules with 35, 40 and 50 mm frames Amerisolar AS-bYxxxZ Where "b" can be 5 or 6; "Y" can be M, P, M27, P27, M30, or P30; and 'T' can be blank, W or WB Aptos modules with 35 and 40 mm frames Aptos Solar DNA-yy-zz23-xxx Where "yy" can be 120 or 144; and "zz" can be MF or BF FAstronergy modules with 30, 35, 40, and 45 mm frames Astronergy Solar aaSMbbyyC/zz-xxx Where "aa" can be CH or A; "bb" can be 60, 66, or 72; "yy" can be blank, 10 or 12; "C" can M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and "zz" can be blank, HV, F-B, or F-BH ASUN modules with 35 and 40 mm frames ASU N AS U N-xxx-YYZZ-aa Where "YY" can be 60 or 72; "ZZ" can be M,or MH5; and "aa" can be blank or BB Auxin modules with 40 mm frames Auxin AXN6y6zAxxx Where "y" can be M or P; "z" can be 08, 09, 10, 11, or 12; and "A" can be F or T Axitec Modules with 35 and 40 mm frames Axitec AC-xxxY/aaZZb Where "Y" can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72, 120, or 144; "b" can be S Boviet modules with 35 and 40mm frames Boviet BVM66aaYY-xxxBB Where "aa" can be 9, 10 or 12; "YY" is M or P; and "BB" can be blank or L BYD Canadian Sola CertainTeed CSUN Ecosolargy ET Solar BYD modules with 35 mm frames BYDxxxAY-ZZ Where "A" can be M6, P6, MH or PH; "Y" can be C or K; and "ZZ" can be 30 or 36 Canadian Solar modules with 30, 35 and 40 mm frames CSbY-xxxZ r Where "b" can be 1, 3 or 6; "Y" can be H, K, P, U, V, W, or X; and 'T' can be M, P, MS, PX , M-SD, P-AG, P-SD, MB-AG, PB-AG, MS -AG, or MS -SD CertainTeed modules with 35 and 40 frames CTxxxYZZ-AA Where "Y" can be M, P, or HC; "ZZ" can be 00,01, 10, or 11; and "AA" can be 01, 02, 03, or 04 Csun modules with 35 and 40 mm frames YYxxx-zzAbb Where "YY" is CSUN or SST; "zz" is blank, 60, or 72; and "A" is blank, P or M; "bb" is blank, BB, BW, or ROOF Ecosolargy modules with 35, 40, and 50 mm frames ECOxxxYzzA-bbD Where "Y" can be A, H, S, or T; "zz" can be 125 or 156; "A" can be M or P; "bb" can be 60 or 72; and "D" can be blank or B ET Solar modules with 35, 40, and 50 mm frames ET-Y6ZZxxxAA Where "Y" can be P, L, or M; "ZZ" can be 60 or 72; and "AX can be WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC Flex modules with 35, 40, and 50 mm frames Flex FXS-xxxYY-ZZ; Where "YY" can be BB or BC; and "ZZ" can be MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAA1 W, SAC1 B, SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W FA GC L modules with 35 mm and 40 mm frames MODULE...: GCL GCL-ab/YY xxx Where "a" can be M or P; "b" can be 3 or 6; and "YY" can be 60, 72, 72H, or 72DH Gigawatt modules with 40 mm frames GigaWatt Solar GWxxxYY Where "YY" can be either PB or MB Hansol modules with 35 and 40 frames Hansol HSxxxYY-zz Where "YY" can be PB, PD, PE, TB, TD, UB, UD, or UE; and "zz" can be AH2, AN1, AN3, AN4, HV1, or JH2 Hanwha Solar modules with 40, 45, and 50 mm frames Hanwha Solar HSLaaP6-YY-1-xxxZ I Where "aa" can be either 60 or 72; "YY" can be PA or PB; and 7" can be blank or B Hanwha Q CELLS Modules with 32, 35, 40, and 42 mm frames aaYY-ZZ-xxx where "aa" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or PEAK DUO; and "ZZ" can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/ Hanwha Q CELLS TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, G5/SC, BLK-G5, BLK-G5/SC, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6/SC, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/SC, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, L-G8.3, L-G8.3/BFF, L-G8.3/BFG, ML-G9 or XL-G9.3 Heliene modules with 40 mm frames FHeliene YYZZxxxA Where "YY" can be 36, 60, 72, or 96; "ZZ" can be M, P, or MBLK; and "A" can be blank, HomePV, or Bifacial HT-SAAE modules with 35 and 40 mm frames HT-SAAE HTyy-156Z-xxx Where "yy" can be 60 or 72, 'T' can be M, P, M-C, P-C, M(S), M(VS), M(V), P(V), M(V)-C, P(V)-C Hyundai modules with 33, 35, 40 and 50 mm frames Hyundai H iY-SxxxZZ "Y" "ZZ" Where can be A, D, M or S; and can be HG, HI, KI, MI, MF, MG, RI, RG, RG(BF), RG(BK), SG, TI, or TG Itek Modules with 40 and 50 mm frames Itek IT-xxx-YY Where "YY" can be blank, HE, or SE, or SE72 JA Solar modules with 30, 35, 40 and 45 mm frames JAyyzz-bbww-xxx/aa JA Solar Where "yy" can be M, P, M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L) (TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, or 72; "ww" can be D09, S01, S02, S03, S06, S09, S10, or S12; and "aa" can be BP, MP, SI, SC, PR, 31313, 4BB, 4BB/RE, 566 Jinko modules with 35 and 40 mm frames J KMYxxxZZ-aa Jinko Where "Y" can either be blank or S; "ZZ" can be M, P, or PP; and "aa" can be blank, 60, 6013, 60H, 60L, 6013L, 60HL, 60HBL, 60-J4, 6013-J4, 6013-EP, 60(Plus), 604, 60-MX, 72, 72-V, 72H-V, 72L-V, 72HL-V, 72-MX, 72H-BDVP, or 72HL-TV Kyocera Modules with 46mm frames KYxxxZZ-AA Kyocera Where "Y" can be D or U; "ZZ" can be blank, GX, or SX; and "AA" can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LF132, LPB2, 3AC, 313C, 3FC, 4AC, 413C, 4FC, 4UC, 5AC, 513C, 5FC, 5UC, 613C, 6FC, 813C, 6MCA, or 6MPA LG modules with 35, 40, and 46 mm frames LG LGxxxYaZ-bb Where "Y" can be A, E, N, Q, S; "a" can be 1 or 2; 'T' can be C, K, T, or W; and "bb" can be A3, A5, B3, G3, G4, J5, K4, or V5 Longi modules with 30, 35 and 40 mm frames Longi LRa-YYZZ-xxxM "a" "YY" "ZZ" Where can be 4 or 6; can be blank, 60 or 72; and can be blank, BK, BP, HV, PB, PE, PH, HBD, HPB, or HPH �ilr Mission Solar modules with 33 and 40 mm frames Mission Solar MSEbbxxxZZaa Where "bb" can be blank or 60A; "ZZ" can be blank, MM, SE, SO, SQ , SR, or TS; and "aa" can be blank, 1 J, 4J, 4S, 5K, 5T, 60, 6J, 6S, 6W, 8K, 8T, or 9S Mitsubishi modules with 46 mm frames Mitsubishi PV-MYYxxxZZ Where "YY" can be LE or JE; and "ZZ" can be either HD, HD2, or FB Motech IM and XS series modules with 40, 45, and 50 mm frames Neo Solar Power modules with 35 mm frames Neo Solar Power D6YxxxZZaa Where "Y" can be M or P; "ZZ" can be B3A, B4A, E3A, E4A, 1-13A, H4A; and "aa" can be blank, (TF), ME or ME (TF) Panasonic modules with 35 and 40 mm frames Panasonic VBHNxxxYYzzA Where "YY" can be either KA, RA, SA or ZA; "zz" can be either 01, 02, 03, 04, 06, 06B, 11, 11 B, 15, 15B, 16, 16B, 17, or 18; and "A" can be blank, E, G, or N Peimar modules with 40 mm frames Peimar SbxxxYzz Where "b" can be G, M or P; "Y" can be M or P; and "zz" can be blank, (BF) or (FB) Philadelphia modules with 35 and 40 mm frames Philadelphia Solar PS-YzzAA-xxx Where "Y" can be M or P; "zz" can be 60 or 72; and "AX can be blank or (BF) Phono Solar modules with 35, 40, and 45 mm frames Phono Solar PSxxxY-ZZ/A Where "Y" can be M, M1, MH, or M1 H or P; "ZZ" can be 20 or 24; and "A" can be F, T, U, or TH Recom modules with 35 and 40 mm frames Recom RCM-xxx-6yy Where "yy" can be MA or MB REC modules with 30, 38 and 45 mm frames REC Solar RECxxxYYZZ Where "YY" can be AA, M, NP, PE, PE72, TP, TP2, TP2M, TP2SM, or TP2S; and "ZZ" can be blank, Black, BLK, BLK2, SLV, or 72 ' ReneSola modules with 35, 40 and 50 mm frames Renesola AAxxxY-ZZ Where "AA" can be SPM(SLP) or JC; "Y" can be blank, F, M or S; and "ZZ" can be blank, Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb Risen S-Energy Renogy Modules with 40 and 50 mm frames RNG-xxxY Where "xxx" is the module power rating; and "Y" can be D or P Risen Modules with 35 and 40 mm frames RSMyy-6-xxxZZ Where "yy" can be 60, 72, 120 or 144; and "ZZ" can be M or P S-Energy modules with 40 frames SNxxxY-ZZ Where "Y" can be M or P; and "ZZ" can be 10, or 15 Seraphim modules with 35 and 40 mm frames Seraphim Energy SEG-aYY-xxxZZ Group Where "a" can be blank, 6 or B; "YY" can be blank, MA, MB, PA, or PB; and "ZZ" can be blank, BB, BG, BW, HV, WB, WW, BMB, BMB-HV Seraphim modules with 40 and 50 mm frames Seraphim USA SRP-xxx-6YY Where "xxx" is the module power rating; and "YY" can be MA, MB, PA, PB, QA-XX-XX, and QB-XX-XX Sharp modules with 35 and 40 mm frames Sharp N UYYxxx Where "YY" can be SA or SC Silfab Modules with 38 mm frames Silfab SYY-Z-xxxAb Where "YY" can be IL, SA, LA, SG or LG; "Z" can be blank, M, P, or X; "A" can be blank, B, H, M, or N; and "b" can be A, L, G, or T Solaria modules with 40 mm frames Solaria PowerXT xxxY-ZZ Where "Y" can be R or C; and "ZZ" can be AC, BD, BX, BY, PD, PM, PM -AC, PX, PZ, WX or WZ Solarcity modules with 40 mm frames Solarcity (Testa) SCxxxYY Where "YY" can be blank, B1 or B2 SolarTech modules with 42 mm frames SolarTech STU-xxxYY Where "YY" can be PERC or HJT SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or SolarWorld AG clear; modules with 31, 33 or 46 mm frames SW-xxx SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or SolarWorld Americas clear; modules with 33 mm frames I SWA-xxx Stion SunEdison I Suniva r Sunpower Sunspark Suntech Stion Thin film modules with 35 mm frames STO-xxx or STO-xxxA SunEdison Modules with 35, 40 & 50 mm frames SE-YxxxZABCDE Where "Y" can be B, F, H, P, R, or Z; "Z" can be 0 or 4; "A" can be B,C,D,E,H,I,J,K,L,M, or N ; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2 Suniva modules with 35, 38, 40, 46, and 50 mm frames O PTxxx-AA-B-YYY-Z MVXxxx-AA-B-YYY-Z Where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1 BO, or 1 B1; and "Z" is blank or B Sunpower standard (G3 or G4) or InvisiMount (G5) 40 and 46 mm frames SPR-Zb-xxx-YY Where "Z" is either A, E, P or X; "b" can be blank, 17, 18, 19, 20, 21, or 22; and "YY" can be blank, BILK, COM, C-AC, D-AC, E-AC, G-AC, BLK-C-AC, or BLK-D-AC Sunspark modules with 40 mm frames SYY-xxxZ Where "YY" can be MX or ST, and "Z" can be M, P or W Suntech Modules with 35, 40 and 50mm frames STPxxxy-zz/aa Where "y" is blank or S; and "zz" can be 20, 24; and "aa" can be Vd, Vern, Vfw, Wdb, Wde or Wd Talesun modules with 35 and 40 frames TP6yZZaaxxx-b Where "yy" can be blank, F or H; "ZZ" can be 60 or 72; "aa" can be M or P; and "b" can be blank, B, T, or (H) Trina Modules with 30, 35, 40 and 46mm frames TSM-xxxYYZZ Where "YY" can be DD05, DD06, DD14, DE14, DE15, DEG15, PA05, PC05, PD05, PD06, PAK PC14, PD14, PE14, or PE15 ; and "ZZ" can be blank, .05, .08, .10, .18, .08D, .18D, 0.82, .002, .00S, 05S, 08S, A, A.05, A.08, A.10, A.18, A(II), A.05(II), A.08(II), A.082(II), A.10(II), A.18(II), H, H(II), H.05(II), H.08(II), HC.20(II), HC.20(II), or M URE modules with 35 mm frames DyZxxxHaa Where "y" can be 6 or 7; "Z" can be K or M; and "aa" can be H3A, H4A, or H8A Vikram solar modules with 40 mm frames VSyy.ZZ.AAA. bb Where "yy" can be M, P, MBB, MH, MS, MHBB, or PBB; rating; and "bb" can be 03.04 or 05 "ZZ" can be 60 or 72; "AAA" is the module power MODULEilr VSUN modules with 35 and 40 mm frames VSUN VSUNxxx-YYz-aa Where "YY" can be 60, 72, 120, or 144; "z" can be M, P, MH, PH, or BMH; and "aa" can be blank, BB, or DG Winaico modules with 35 and 40 mm frames Winaico Wsy-xxxZa Where "y" can be either P or T, "Z" can be either M, P, or MX; and "a" can be blank or 6 Yingli Panda, YGE, YGE-U, and YLM series modules with 35, 40, and 50 mm frames ZNShine Modules with 30, 35, and 40mm frames ZNShine ZXy6-ZZaa-xxx/b Where "y" can be M or P; "ZZ" can be blank, H, HLD, HLDD, LID, LDD, NH, NHLD or NHLDD; "aa" can be 60, 72, 120 or 144; and "b" can be M or P FRAMELESS•D_ Astronergy Solar Astronergy frameless modules CHSM6610P(DG)-xxx Canadian Solar frameless modules Canadian Solar CSbY-xxx-Z Where "b" can be 3 or 6; "Y" is K, P, U, or X; and "Z" can be M-FG, MS-FG, P-FG, MB-FG, or PB-FG Jinko Jinko frameless modules JKMxxxPP-DV Prism Solar frameless modules Prism Solar BiYY-xxxBSTC Where "YY" can be 48, 60, 60S, 72 or 72S Risen frameless modules Risen RSMyy-6-xxxZZ Where "yy" can be 60, 72, 120 or 144; and "ZZ" can be MDG or PDG Stion Stion frameless modules STL-xxx or STL-xxxA Sunpreme frameless modules Sunpreme GXB-xxxYY Where "YY" can be blank or SL Trina frameless modules Tri n a TSM-xxxYY Where "YY" can be either DEG5(II), DEG5.07(II), DEG5.40(II), DEG5.47(II), DEG14(II), DEG14C(II), DE- G14C.07(II), DEG14.40(II), PEGS, PEG5.07, PEG5.40, PEG5.47, PEG14, or PEG14.40